HomeMy WebLinkAboutINSULATION INTALLATION CERTIFICATEINSULATION INSTALLATION CERTIFICATE SCANNED
BY
TO: JWN Construction LOT_ BLOCK: SECTION: UCiecount /
JOB#: 49895 JOB NAME: Wismer Res
JOB ADDRESS: 720 Nettles Blvd, Jensen Beach
The undersigned hereby certifies that insulation has been installed at the above described property as
follows:
1. Exterior CBS walls have been insulated with ............................Check one ( ) Spray on cellulose
to a thickness of inches, which thickness, according to the ( ) Fiberglass blankets
manufacturer, ( ) Aluminum Foil
Density .51b will yield an "R" value of ( ) Other
Exterior Frame walls have been insulated with ............................Check one () Spray on cellulose
to a thickness of 3.50 inches, which thickness, according to the Fiberglass blankets
manufacturer, Knauf ( ) Aluminum Foil
Density .51b will yield an "R" value of 11 ( ) Other
2. Ceilings Main have been insulated with .........................Check one () Fiberglass blankets
to a thickness of 5.50 inches, which thickness, according to the () Fiberglass loose fill
manufacturer, Demilac O Alumi^^^ n^"
Density .51b will yield an "R" value of 21 (,0 Other Polyurethane Spray Foam
Ceilings have been insulated with .........................Check one ( ) Fiberglass blankets
to a thickness of inches, which thickness, according to the ( ) Fiberglass loose fill
manufacturer, ( ) Alum;-— a^;]
Density .51b will yield an "R" value of 21 ( ) Other Polyurethane Spray Foam
3. Interior knee walls have been insulated with.................................Check one ( ) Fiberglass blankets
to a thickness of 5.50 inches, which thickness, according to the ( ) Polyurethane
manufacturer, Demilac ( ) Spray - 11,0
Density .51b willyield an "R" value of 21 (,0 Other Polyurethane Spray Foam
i
4. Garage partition walls of conditioned living areas have been
insulated with................................................................................Check one (,/) Fiberglass blankets
to a thickness of 3.50 inches, which thickness, according to the ( ) Spray on cellulose
manufacturer, Knauf ( ) Polyurethane
Density .51b will yield an "R" value of 11 ( ) Other
MULTI FAMILY RESIDENTIAL CONSTRUCTION ONLY: The common (party) walls separating
different tenants shall be insulated as follows - Frame/Metal stud walls R-1I (Min.); CBS or Concrete walls
R-3 (Min.); by Energy Code requirements. See Energy Code Rev. 1/87, paragraph 903.2(b), on page 9-17,
latest edition. These "minimums levels of insulation' are not included in the Energy Calculations, but shall
be installed in the field.
NOTE: Densities of sprayed on, loose fill, or any other composed -on site insulati all be the P.C.F.
(lb/ft3) average of three (3) "DRY SAMPLES" of actual 'install n..
LEED FIREPROOFING & INSULATION. INC. C�� ( ' /k
Insulation Contractor Insulation Contractor Signature ' s46�
Martin County - SP 02474 09/09/08
Insulation Contractor's CC# Date of G