Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. S Sfreet: ` - City, State, Zip: FT. PIERCE, FL, `� � W\ Permit Office: ST. LUCIE COUNTY Permit Number: BY .I CoUC1 bLV St. Lucie Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1446.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1446.00 ft2 6. Conditioned floor area above grade (ft2) 1446 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(141.3 sqft.) Description Area a. Sup: Attic, Rat: Attic, AH: Attic 6 250 a. U-Factor. Sgl, U=1.04 101.25 ft2 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency • d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. - Area Weighted Average SHGC: 0.284 14. Hot water systems 8. Floor Types (1445.5 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2 b. Conservation features EF: 0.970 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.098 Total Proposed Modified Loads: 46.31 PASS Total Baseline Loads: 48.06 1 hereby certify that the plans and specifications covered by Review of the plans and 4811E STgl this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance yQi ii„t� •,cr,; +n with the Florida Energy Code. rrn,G"'." PREP ED Before construction is completed a DATE�-( this building will be inspected for compliance with Section 553.908 - - A * Y e I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code OWNER/ N<: Op W"'{FV BUILFINUFlAL' COP' DATE: as DATE: - Compliance requires certification by the air handler unit manufacturer that the. air,handI7&r0 Q8ifres as certified factory -sealed in accordance with R403.3.2.1. ,0���y,�p A ��(!C - Compliance requires an Air Barrier and Insulation Inspection Checklist in Zc�cQ It ma.4xVy.R�°dn�tt &project requires an envelope leakage test report with envelope leakage no greater than 7.00 Al�4iU0.0 1 �� r,/out4TY ST. W BOOO 9/13/2019 9:39 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address 86ilding Type: User Conditioned Area: 1446 Lot # Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated ^ 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 301 ft' -- 0 1 0 2 Slab -On -Grade Edge Insulatio WIC t ft 0 63 ft' -- 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft' _- 0 1 0 4SIab-On-Grade Edge Insulatio KITCHEN t ft 0 192 ft' ___ 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft' -- 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft' __- 0 1 0 7Slab-On-Grade Edge Insulatio ENTRY 7 ft 0 55 ft' ____ 0 1 0 9/13/2019 9:39 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY Eft 0 42 ft' 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft' _- 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft' 240 ft' Light N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 301 ft' 0.1 Wood 2 Under Attic(Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft' 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft' 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft' 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft' 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft' 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft' 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft' 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 NE=>SW Exterior Concrete Block - Ext Ins(BEDROOM 4.1 10 0 8 0 80.0 fP 0 0 0.4 0 2 SW=>NE Exterior Concrete Block - Ext Ins(BEDROOM 4.1 28 0 8 0 224.0 ft 0 0 0.4 0 3 NW=>SE Exterior Concrete Block- Ext Ins(BEDROOM 4.1 14 0 8 0 112.0 ft' 0 0 0.4 0 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft' 0 0 0.4 0 5 NE=>SW Exterior Concrete Black- Ext Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.4 0 6 NE=>SW Exterior Concrete Block- Ext ImHEDROOM 2 4.1 16 0 8 0 128.0 ft' 0 0 0.4 0 7 SE=>NW Exterior Concrete Block - Ext InIKDROOM 2 4.1 10 0 8 0 80.0 ft' 0 0 0.4 0 8 S=>N Exterior Concrete Block - Ext InREDROOM 2 4.1 4 3 8 0 34.0 ft' 0 0 0.4 0 9 SW=>NE Exterior Concrete Block - Ext InfiEDR00M 2 4.1 2 0 8 0 16.0 ft' 0 0 0.4 0 10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft' 0 0 0.4 0 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft' 0 0 0.4 0 12 SW=>NE Exterior Concrete Block - Ext InsdlAUNDRY 4.1 6 0 8 0 48.0 ft' 0 0 0.4 0 13 NE=>SW Exterior Concrete Block - Ext InsGREAT/DINT 4.1 26 0 8 0 208.0 ft' 0 0 0.4 0 • 14 NW=>SE Exterior Concrete Block -Ext InsflREAT/DINI 4.1 20 0 8 0 160.0 ft' 0 0 0.4 0 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft' 0.23 0.4 0 9/13/2019 9:39 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE_ 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW 13 Metal 5 NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes 1.04 0.29 N 32.9 ft' 1 ft 0 in 1 ft 5 in 1.04 0.29 N 6.9 ft' 1 ft 0 in 1 ft 5 in 1.04 0.29 N 24.0 ft' 6 ft 0 in 1 ft 5 in 1.04 0.29 N 37.5 ft' 1 ft 0 in 1 ft 5 in 1.11 0.27 N 40.0 ft' 8 ft 0 in 1 ft 5 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft' 315 ft' 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .1233 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft' 9/13/2019 9:39 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DUCTS — Supply — --- Return — Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 250 ft' Attic 65 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablree Thermostat: Y Ceiling Fans:Coollng HeDec Jan b Feb Marr[ fan j [[[[ ]]]] I I rJunDC i rr ri Sep]Oct][X �X� �X] OctO [[X]] [ ] [ Mar l�l Apr May Jun [ Jul Aug Sep t [X� Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(81bs/sq.ft. 0 ft' 0 ft 0.3 BEDROOM Default(8 lbs/sq.ft. ft' ft 0.3 WIC Default(8 Ibs/sq.ft. ft' ft 0.3 M. BATH Default(8 lbs/sq.ft, ft' ft 0.3 KITCHEN ' Default(8 lbs/sq.ft. ft' ft 0.3 BATH Default(8 Ibs/sq.ft. ft' ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' ft 0.3 ENTRY Default(8 lbs/sq.ft. ft' ft 0.3 LAUNDRY Default(8 Ibs/s .ft. ft' ft 0.3 GREAT/DINING 9/13/2019 9:39 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y U Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY w x Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind noina and wirino Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire snronkler cover nlateg and walls or ceilinm a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 9/13/2019 9:40 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a), Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1446 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.060 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.284 14. Heating system: Capacity 34.8 c) Area 7c. 141.3 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 0 Heat recovery unit HeatReC% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature:�\� Date: �` < r,l 1 Address of New Home: \ � / City/FL Zip: FT. PIERCE. FL - `W FTZ 9/13/2019 9:39:40 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Project Summary o te1 - wrightsoftEntire House By: QUICK CALCS, INC. 31.7 ST. LUCIE I-R. Fr. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Emil: QUICKCALCS@AOL.COM For. WYNNE DEVELOPMENT CARLTON III, FT. PIERCE, FL Notes: SCANNED BY St. LucieCountyy Design• • Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF OF Outside db 90 OF 75 OF Inside db 70 Inside db Design TD 28 OF Design TD 15 OF L Daily range Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 19276 Btuh Structure 16785 Btuh Ducts 5900 Central vent (0 cfin) 0 Btuh Btuh Ducts 8919 Btuh Central vent (0 cim) 0 Btuh Humid (gone) 0 Btuh none Blower 0 Btuh Piping 0 Equipment load 25176 Btuh Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 24418 Btuh Infiltration Method Simplified Latent Cooling Equipment Load Sizing Construction quality Fireplaces Average 0 Structure 2065 Btuh Ducts 2429 Stuh Central vent (0 cim) 0 Btuh Heatingg Area (ft) 1602 Coolingg 1602 (none) Equipment latent load 4493 Btuh Volume (fP) 14827 Airchanges/hour 0.38 14827 0.20 Equipment Total Load (Sen+Lat) 28912 Btuh Equiv.AVF (cfrn) 94 49 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Make Carrier Trade CARRIERAIR CONDITIONING Model 25HBC536A*030 Cord 25HBC536A*030 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER,15 SEER Heating Input Heating output 34600 Btuh @ 47'F OF Sensible coolir)gI�'�24360 Btuh Btuh Latent cool(n �/E® F Btuh Temperature rise 27 Total coolipi7b®E C®���' 0 Actual airflow 1160 cfm Actual air w A Airflowfac rr Btuh Airflow factor 0.046 Static pressure 0 cfmBtuh in H2O Static pressure" ��COE C®UN* in H2O Space thermostat Load sensible heat rati�® t7 tsl3 Capacity balance point = 34 OF CC Backup: FILE COPY Input=7kW, Output=23009Btuh,100AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 4l'- wrights ft- 2019-Aug-1509:15:00 •—.•-.-+ R1gtt-Su[e6Urivew1201919.0.07 RSU06101 Page t ...rtslWrigHsoft HVAC\WYNNE-THE GRAND CARLTONnp Calc=MJ8 Frort DoorPaces: N I wrightsoft• Right-J®Worksheet Job: Entire House By: By: QUICK CALCS, INC. 317,ST. LUCIE LN.,FT. PIERCE, FL 34946 Phone: 772466-6799 Fax. 772-466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name EVosedvall Room height Room dimensions Room area Entire House 1612 it 9.3 it d 1601.5 ft252.0 BEDROOM 41.0 it 8.0 it heaVmol 14.0 x. 18.0 it ff` Ty Construction number U-value (BtuWM F) Or HTM (BtuhM Area (IF) or perimeter (f0 Load (Btuh) Area (ft) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 Wl�,1--. �G 18A400s tA_glom 13A4ocs 1A-dom 11D0 _.. 0.143 1270 ne _ne- se se se 4.00 35,56 4.00 35.56 10.92 2.55 _70.43 2.55 70.95 11.31 - 551 80 128 20 21 513 2055 1344 348 711 229 1306 ,2662 221 1419 238 72 0 72 0 288 0 183 0 W 0.143 1270 0.390 87 0 21 0 0 0 0 0 0 0 0 0 0 0 0 W W 13A-4om 13A4as JAclom tA.alom -13A4as IA-lom 10-clom 4A5-2omd. 12C-Ow �0.143 1270 1270 1270 _S_ sw W nu 4.00 4.00 35.56 35.55 �_2.55 2.95 70.95 70.95 255 4524 4524 36.90 128 416 416 6 20 ,_90 390 0 0 _ 1562 1213 213 86 426 419 0 144 0 0 40 144 0 0 0 0 570 0 0. 360 0 0 _ ^, W 0.143 12M 1270 0.770 riw nw, nw mv_ 400 35.56 35.56 21,56 2.55 352 12 12 41 288 0 0 0 _711 1151 415 427 880 73-2 732 528 543 1505 112 12 12 0 88 0 0 0 354 415 427 0 225 528 543 0, P 0.091 120 120 306 154 0 0 0 0 C IF 16A30md 27P,-ml 0.032 0.989 = - 090 27.69 _2.32 0.00 1602 1602 1002 161 _ 1495 4463 3725 0 _252 252 _252 41 d226 1135 685 0 6 c)AED e>rarrson 23 197 Em,elope IoWgain 16386 15970 3421 2627 12 a) Infiltration b) Room ventilation 2890 0 815 0 640 0 180 0 13 Internal gains Omlpants@ 230 Appliance.4oher 0 0 0 0 0 0 Subtotal Qines6 to 13) 19276 16785 4061 2807 14 15 Lessextemalload Lesstansfer Redistribution Subtotal DuUloads 31% 53% 0 0 0 19276 5900 0 0 0 16785 8919 31% 53% 0 0 0 4061 1243 0 0 0 2807 1491 Total room load Air required (dim) 25176 1160 25704 1160 5304 244 4298 194 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -• r- wrlghtvofC- 2019-Aug-1509:15:00 AF Riga-Sute®Uriversal 201919.0.07 RSU08101 Page 1 ..rts\Wdgtdsoft WAC\WYNNE-THE GRAND CARLTONnp Calc=MJB Frori Doorfaces: N wrightsoft' Right-M Worksheet Job: Entire House Date: ey: QUICK CALCS, INC. 317-ST. LUCIE LN., FT.PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Emil: OU1CKCALCSQAOL.COM 1 2 3 4 5 Room name E>glosedwall Room height Room dimensions Room area WIC 0 ft 8.0 ft heaV=1 7.0 x 9.0 It 63.0 ft' MASTER BATH 17.0 It 8.0 It heal/cool 7.0 x 17.0 It 119.0 ft' Ty Consructon number U-value (BtuhAV-T) Or HTM (BWIv1l') Area (ft) or perimeter (ft) Lead (Bblh) Area (ft') ar perimeter (R) Load (Stull) Heal Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 11 YtJ _G WI - E- G I-D 13A-4= 1*10M 13A4acs 1AcIom 11D0 0.143 _1270 0.143 1270 0.390 ne _ne,.._35.56 se se se 4A0 4.00 35.56 10.92 2.55 _70.43 2.55 70.95 11.31 0 10 0 __0 0 0 0 0 0 -0 0 - 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0_ 0 0 0 W= N/ 13R-0as 13A400s 1Aclom 1Aciom '13A4ocs 1AcIcm 1AcIom 4A5.2omd _1.2C�v 16A30md 22A-fpl _0,1.43 0.143 1270 1270 _s_ sw sr+ sN 4.66 4.00 35.56 35.56 4.00 35.56 35.66 _21.56 255 _069 27.69 _2.55 2.55 70.95 70.95 -2.55-0-0 4524' 45.24 _3,6.90 128 _2.00 0.00 0 0 _._0 0 0 0 0 0 0 0. 521 213 0 0 331 426 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 136 6 0 130 0 0 _ W 0.1-443 1270 1270 0.770 0.091 ma nw nw _nw- - 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0_ _G P ,C F 0 0 0 55 0 0 0 0 0 _0.032 0.989 = - 63 63 63 0 _140 0 _119 119 717 _-471 _ 471 _276. 0 17 6 c)AED e=rsion -10 55 Envelopelossrgain 56 133 1311 1087 12 a) Infiltration b) Roomtentlation 0 0 0 0 265 0 75 0 13 Internal gains O=pants@ 230 Applianoeslother 0 0 0 0 1 0 0 Subtotal olms6 tt 13) 56 133 1577 1162 14 15 Lesse)demal load I-miransfer Redistribution Subtotal Ductloads 31% 53% 0 0 0 56 17 0 0 0 133 71 31% 53% 0 0 0 1577 483 0 0 0 1162 618 Total room load Air required(crm) 74 3 204 9 2059 95 1780 80 �Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -ii =lath mffc- 2019-Atg-1509:15.00 A8 RigttSdteSUnvem120I919.0.07RSU08101 Paget ..sts\Wrigttwft HUAC\WYNNE-THE-GRAND CARL7ONnp Calc=MJ8 Frort Doorfaces: N Wrightsoft- Right-M) Worksheet Job: Entire House Date: QUICK CALCS, INC. sy 317.ST. LUCIE LN.,FT. PIERCE, FL 34946 Phone: 772-466-6799 Fa 772-466-6796 Email: OUICKCALCS@40LCOM 1 2 3 4 5 Room name 67osedvall Room height Room dimensions Room area KfrCHEN 0 It 8.0 It heaVcool 1.0 x 192.0 It 1920 IV BATH 5.0 ft 9A It hwVocol 9.0 x 5.0 ft 45.0 ft' Ty Construction number U-value (Btuhfili°F) Or HTIVI (Blull" Area (IF) or perimeter (fp Load (Btuh) Area (" or perimeter (f0 Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6✓ 11 T--G, 4.00 _ 35.56 4.00 35.56 10.92 2.55 _70.43 2.55 70.95 11.31 3-K4 is - 0.143 270 0.143 1270 0.390 ne _ne- se se se 0 0 0 __0 0 0 0 0 0 0 0 47 __0 0 0 0 -47 _ 0 0 0 0 188 0 120 „-_0 0 0 0 -IAciom 13A-4o5 1Actom 11DO 0 0 0 0 0 0 0 0 0 0 0 0 W= IW J3A-4 13A-0ors 1A-clom tAClom =0,143 0.143 1270 1270 0.149 1270 1270 .0.770 0.091 0.032 0.989 _n_ sw sw sw -rr nw nw _mv- ^ - 4. 00 4.00 35.56 35.56 4A0 35.56 35.58 _21.56 2.55 = 0.90 27.69 _2.55 2.55 70.95 70.95 2.55 4524 4524 _36.90 128 _2.32 0.00 ,7_0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I--v __-G_- W G 13A`-0dcs tAclom •1A-dom 4A5-2omcl 12C-0sw 16A-:SOmdd 22A-tol 0 0 0 0 0 0 0 0 0 0 -0-0-0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 P = F 0 _192 192 -----0 0 -0 0 0 0 0 0 0 192 0 172 0 445 0 45 45 45 5 40 138 _104 0 6 c)AEDe rslon 39 -22 Emelope losygsin 172 406 367 202 12 a) Infiltration b) Roomeentlation _ 0 0 0 0 1 92 0 26 0 13 Intemalgains Owupants@ 230 Applianoesrother 0 0 0 0 0 0 Subtotal(lines6L7'13) 172 406 459 228 14 .15 Lessodemalload Lessbansfer Redistribution Subtotal DuCloads 31% 53% 0 0 0 172 53 0 0 0 406 216 31% 53% 0 0 0 459 140 0 0 0 228 121 Total room load Air required(dm) 225 10 622 28 599 28 349 16 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. "PIT we lgtit9oR- 2019-Aug-1509:15:00 ACA Rigtf-Suite® Universal 201919.0.07 RSU08101 Pages ...rlslWrigftsoff HVAC1WYNNE-THE GRAND CARLTONrp Calc=MJB Frani Doorfaces: N wrightsoft- Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317.ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name E)poWdvall Room height Room dimensions Room area BEDROOM2 302 it 8.0 ft heat/owl 1.0 x 190.5 it 190.5 ft2 ENTRY 6.0 1t 8.0 ft heaf/mol 6.0 x 10.0 ft 60.0 ft2 Ty Construction number U-value (Biuh&t F) Or HTM (Btuhlp Area (ft� or perimeter (it) Load (Bbh) Area (ft2) or perimeter (ft) Load (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 y! L-G 13A4oCS 1Ac1om 13A4ors 1Aclom 11D0 0.143 _1270 0.143 1270 0.390 ne _ne- se se w 4.00 ._35.56 4.00 35.56 10.92 2.55 _70.43 2.55 70.95 11.31 120 0 120 0 480 0 305 - 0 -0-0-6 0 0 0 0 0 69 0 238 W 80 20 0 60 0 0 240 711 0 153 1419 0 48 0 21 27 0 21 108 0 229 W7 W 13A46 13A40os 1Ac1om 1A-clom 0143 0.143 1270 1270 -0.143rnv 1270 1270 0.770 0_091 =0.032 0.989 _s_ sw sw sw my nw _nw. - = - 4A0 4.00 35.56 35.56 4.00 35.56 35.56 _21.56 255 1090 27.69 1265 2.65 70.95 70.95 2.55 4524 4524 _36.90 128 12.32 _34 8 0 0 _34 8 0 0 136 32 0 0 86 20 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 eta �G W I--G IL---GG 13A4aS 1Aclom 1Actom 4A6-2gmd 1_2C-Ow 0 0 0 0 0 o 0 0 0 -0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _. P 0 0 0 :_0 0 0 0 =___54 166 0 C7 F 10A30md 22A-Ipl -191. 775 835 4-42 0 _60 60 60 6 _139 0 0.00 191 _191 30 6 c)AED exanaon 209 41 EmeJope loss/gain 2606 2635 557 404 12 a) Infiltration b) Room ventilation 472 0 133 0 94 0 26 0 13 Internal gains Omrpants@ 230 Applianoagother 0 0 0 0 0 0 Subblal illness to 13) 3078 2768 651 430 14 ,15 LesseArnalload Lesstransrer Redistribution Sublote Duo:loads 31% 53% 0 0 0 3078 942 0 0 0 2768 1471 31% 53% 0 0 0 651 199 0 0 0 430 229 Total room load Air required(cfm) 4020 185 4239 191 850 39 659 30 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. A � wWrtg �tsaPC- 2019-Aug-1509:15:00 Right-SuiteSUriversa12019 19.0.07RSU08101 Page 4 ..rislWrigfboftHVAC\WYNNE-THE GRAND CARLTON.np Calc=MJ8 Fror/Doorfaces:N wrightsoft' Right-M Worksheet Job: Entire House Dale: By: QUICK CALCS, INC. 317,ST. LUCIE LN,Fr.. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Emil: OUiCKCALCS@AOL.COM 1 2 3 4 5 Room name Elpo:edvall Room height Room dimensions Room area LAUNDRY 6.0 It 8.0 ft hearV000l 7.0 x 6.0 It 42.0 ft' GREATIDINING 46.0 it 12.0 It heatcool 1.0 x 488.0 It 488.0 fl2 Ty Con truojon number U-vdlue (BtuhAl;°F) Or HTM (Bluhfin Area W) or perimeter (ft) Load (Bluh) Area (fe) or perimeter (f) Load (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross NIPS Heat Cool 6 11 N,! L-G 13AAo 1Ac1om 13A-0as 1A-dom 11DO T3A_40{s 13A-0oo; tAclom 1Aclom 13CAos 1AcIom 4A5.2om_d 12C-O w 3600md 22A-ml 0.743 1270 -We- _ne- se se se = sw w _sv nW nw nw _nw, - - 4.00 �35.56 4.00 35.56 10.92 _4.00 4.00 35.56 35.56 400 3556 3556 _2156 255 =090 27.69 2.55 _70.43 2.55 70.95 11.31 _2.55 2.55 70.95 70.95 - 0 0 -0 0 -0 0 0 0 312 38 0 0 0 274 0 1098 1344 0 0 0 698 _2662 0 0 0 W D 0.143 1270 0.390 =0143 0.143 1270 1270 0.143 1270 1270 _0.770 0.091 _0.032 0.989 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 N= W 0 48 0 0 0 48 0 0 0 192 0 0 0 122 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ==O 0 0 0 W _ ti1AcIom 2.55 45.24 45.24 36.90 1.28 =2.32 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 240 '0 0 41 199 0 0 0 798 0 0 840 __0 437_ 1274 507 0 0 1505 0 __7132 0 P C IF 0 0 0 0 i 0 488 488 0 486 46 42 42 42 6 97 _36 166 0 6 c)AEDe rsion -22 -597 Emelopelossrgain 396 198 5830 5908 12 a) Infiltration b) Roomventlation 94 0 26 0 1077 0 304 0 13 Internal gains Ooarpants@ 230 Applianoasrother 0 0 0 0 1 0 1 0 Subtotal (lines 6 to 13) 490 224 6907 6212 14 .15 LesseMemalload Lesshansfer Redistribution Subtotal Dudloads 31% 53% 0 0 0 490 150 0 0 0 224 119 31% 53% 0 0 0 6907 2114 0 0 0 6212 3301 Total room load Arrequired(dm) 640 29 344 16 9022 416 9512 429 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -_i wrtgtrrfaoR` 2019-Aug-1509:15:00 RigH-Sute®Uriversal 201919.0.07 RSU08101 Page 5 ..Aa Wrigltsoft HVAC\WYNNE-THE GRAND CARLTONxp Calc=MJ8 FrortDoorfams: N Wrightsoft' Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317.ST. LUCIE LN., FL PIERCE, FL 34946 Pore: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name E posedwall Room height Room dimensions Room area BEDROOMS 10.0 it 8.0 it heall000l 15.0 x 10.0 it 150.0 W Ty Construdon number U-value (BWh/fti°F) Or HTM (BUM Area (ft0 or perimeter (ft) Lead (BWh) Area or perimeter Load Heat Cool Gros N/P/S Heat Cool Gros N/P/S Heat Cool 6 11 W 13C4 1A-d m-- 0.143 ne _ne. se se se 4A0 _35.56 4.00 35.56 10.92 2.55 ,_70.43 2.55 70.95 11.31 0 0 0 0 0 0 0 0 W D 13AAoc; tAcIom 11DO _7270 0.143 1270 0.390 0 0 0 0 0 0 0 0 0 0 0 0 WW_ W j3A-0ocs 13A-0ots 1AcIom 1AcIom 13A-40M 1A�Icm 1Ac1om _4A$2omd 12C-O w 16A30md 22A-WI _0143 0.143 1270 1270 0,143 1270 1270 _0.770 0,091 _0.032 0.989 _ _ sN sw sv 400 4.00 35.56 _35.56 4.00 35.56 35.56 _21,56 2.55 _090 27.69 _255 2.55 70.95 70.95 2.55 4524 45.24 36:90 128 _2.32 0.00 '0 80 0 20 - 0 0 0 0 0 60 0 0 0 240 0 711 0 153 0 1419 W ' nw nw nw nw. - 0 0 0 0 0 0 0 0 0 0 0 0 - `.. P C. F 120 150 150 120 306 154 _348 0 j50 10 134 277 6 c)AED emersion 296 Envelope lossi9ain 1669 2369 12 a) Infiltration b) Roomventlalon 156 0 44 0 13 Internal gains Oovpants@ 230 Appliancesfolher 0 0 0 Subtolal(lines6to13) 1825 2413 14 15 Lese,demalload Leistransfer Redistribution Subtotal Ductloads 31% 53% 0 0 0 1825 559 0 0 0 2413 1282 Total room load Air required (Qm) 1 2383 110 W95 167 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. .wWvwhf soTt` 2019-Aug-1509:15.00 A� Riglt-Sute®Universal 201919.0,07 RSU08101 Page 6 ..rtslWrigtisoft HVAC\WYNNE-THE GRAND CARLTON.rp Calc=MJB FroriDwNces: N