HomeMy WebLinkAboutREVISION - BUILDING PERMITOFFICE USE ONLY:
DATE FILED:
REVISION FEE: 0 b
PERMIT # 1908-0355
RECEIPT #
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENU
FORT PIERCE, FL 34982-RRAS10F
(772)462-1553.F4X(779)4C`
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION SCANNED
1. LOCATION/SITE _MONTEREY BY
ADDRESS: ly S$. LUGI2 onniy
2. DETAILED DESCRIPTION OF PROJECT
REVISIONS:
REVISED ENERGY CALCS TO SHOW 50 GALLON HOT WATER HEATER
3.
4.
5.
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #:
BUSINESS NAME:
QUALIFIERS NAME6 South US
ADDRESS: 2ai1u1u�
CITY: ' Fort St. Lucie
PHONE (DAYTIME)
OWNER/BUILDER INFORMATION:
NAME:
ADDRESS:
CITY:
PHONE:
Wynne Building Corporation
ARCHITECT/ENGINEER INFORMATION:
ST
COUNTY CERT. #: 8898
- ZIP: '`*"
FAX: 772 7 -7 56
FAX:
NAME: BRADEN & BRADEN
ADDRESS: 417 COCON UT AVE.
CITY: STUART STATE: FL ZIP: 34996
PHONE (DAYTIME): (772) 287-8258 FAX:
Revised 07/22/2014
nH%qS1G.k FILE COPY
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: THE GRAND CARLTON IMPACT
Builder Name: WYNNE BUILDING COPR.
\VNNE
Street: IN\ ��\ _ �
`
Permit Office: ST. LUCIE 000NTY
City, State, Zip: FT. PIERCE, FL, �
Permit Number.
Owner. WYNNE BUILDING CROP
Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types(1442.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1250.00 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
R=11.0 192.00 ft2
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1476.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1446.00 ft2
6. Conditioned floor area above grade (ft2) 1446
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floor area below grade (ft2) 0
°. N/A
R= ft2
7. Windows(141.3 sqft.) Description Area
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
R ft2
6 175
a. U-Factor. Sgl, U=1.04 101.25 ft2
SHGC: SHGC=0.29
b. U-Factor. Sgl, U=1.11 40:00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
- c. U-Factor. N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft:
Area Weighted Average SHGC: 0.284
14. Hot water systems
8. Floor Types (1445.5 sqft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1445:50 ft2
b. Conservation features
EF: 0.970
'b. N/A R= ft2
None
'
c. N/A R= ft2
15. Credits
Patel
Glass/Floor Area: 0.098 Total Proposed Modified Loads: 47.47
PASS
Total Baseline Loads: 48.09
I hereby certify that the plans and specifications covered by
Review of the plans and
rf#f��T9
this calculation are in compliance with the Florida Energy
specifications covered by this
Code. P
calculation indicates compliance
with the Florida Energy Code.
nm
PREPARED F}y;
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
r
hereby certify that this building, as designed, is in compliance
Florida Statutes.
With the Florida Energy Code.®7y
OWNE
BUILDING OFFICIAL:
DATE:DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualities as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Alr Barrier and Insulation Inspection Checklist in accordance with 11402A.1.1 and_tproject requires an
envelope leakage test report with envelope leakage no reaterrtfthan 7.00 ACH50 (R402.4.1.2).
RE�IIE� V- FOR
CODE COMPLIANCE
T �UCIE COUNTY
4/21/2020 10:27 AM EnergyGauge4D MAB.b.02 (Rev.11)- e 2 BC 6th Edition (2017)
REVISION
Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE GRAND CARL Bedrooms: 2
Address Type:
Street Address
Building Type: User Conditioned Area: 1446
Lot #
Owner Name: WYNNE BUILDING CROP Total Stories: 1
Block/Subdivision:
#of Units: 1 Worst.Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180
Street: -
Permit Office: ST. LUCIE COUNTY Cross Ventilation: No
County:
St. Lucie
Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
—Comment:. _
CLIMATE
/ Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location TMY Site 97.5 % 2.5 %
Winter /Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75 299
62
LOW
BLOCKS
Number Name Area Volume
1 Entire House 1446 11568
SPACES
Number' Name Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 BEDROOM 301 2408 No 0
1
1 Yes
Yes
Yes
2 WIC 63 504 No 0
1 No
Yes
Yes
3 M. BATH 56 448 No 0
1 Yes
Yes
Yes
4 KITCHEN 192 1536 Yes 0
1 No
Yes
Yes
5 BATH 45 360 No 0
1 Yes
Yes
Yes
6 BEDROOM 2 204 1632 No 0
1
1 Yes
Yes
Yes
7 ENTRY 55 440 No 0
1 Yes
Yes
Yes
8 LAUNDRY 42 336 No 0
1 Yes
Yes
Yes
9 GREAT/DINING 488 3904 No 0
1 Yes
Yes
Yes
FLOORS
# RwType Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0
301 ft'
0 1
' 0
2SIab-On-Grade Edge Insulatio WIC 1 ft 0
63 ft°
_
0 1
0
3 Slab -On -Grade Edge Insulatio M. BATH Sit 0
56 fP
—
0 1
0
4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0
192 ft'
_
0 1
0
5 Slab -Oh -Grade Edge Insulatio BATH '5 ft 0
45 ft'
_
0 1
0
68Iab-On-Grade Edge Insulatio BEDROOM 2' 32.2 ft 0
203.5 ft'
0 1
0
7 Slab -On -Grade Edge Insulatio - ENTRY 7 it 0
55 ft'
__
0 1
0
4/2112020 10:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRea2017 FSC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY Eft
0
42 ft2
0
1
0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0
488 ft2
_
0
1
0
ROOF
/ Roof
Gable
Roof
Red
Solar
SA Emitt
Emift Deck
Pitch
V # Type Materials Area
Area
Color
Bart
Absor.
Tested
Tested Insul.
(deg)
1 Gable or Shed Metall 1524 ft2
240 ft2
Light
N
0.6
No 0.9
No 0
- 18.4
ATTIC
# Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
150
1446 ft2
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Free
Truss Type
1 Under Attic (Vented) BEDROOM
30
Blown
301 ft-
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ft-
0.1
Wood
3 Under Attic (Vented) M. BATH
30
Blown
56 ft-
0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft-
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45ft-
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
7 Under Attic (Vented) ENTRY
30
Blown
55 ft2
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
-42 ft2
0.1
Wood
9 Under Attic (Vented) GREATIDINING
30
Blown
488 ft2
0.1
Wood
10 Knee Wall (Vented) GREAT/DINING
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing Solar
Below
0
_ 1 NE=>SW Exterior Concrete Block - Int InsLMEDR0OM
4.1 10
0 8
0
80.0 ft'
0
0
0.4
0
2 SW=>NE Exterior Concrete Block- Int InsuBEDROOM
4.1 28
0 8
0
224.0 ft2
0
0
0.4
0
3 NW=>SE Exterior Concrete Block - Int InsuBEDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.4
0
_ 4 SW=>NE Exterior Concrete Block - Int Insul M. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.4
0
_ 5 NE=>SW Exterior Concrete Block - Int Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.4 ,
0
_ 6 NE=>SW Exterior Concrete Block- Int InsEEDROOM 2
4.1 16
0 8
0
128.0 ft-
0
0
0.4
0
_ 7 SE=>NW Exterior Concrete Block - Int InsBEDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
6 S=>N Exterior Concrete Block - Int InsBEDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.4
0
_ 9 SW=>NE Exterior Concrete Block - Int Ins81EDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.4
0
10 SE=>NW Exterior Concrete Block - Int Insul ENTRY
4.1 6
0 8
0
48.0 ft2
0
0
0.4
0
11 SW=>NE Exterior Concrete Block- Int Insul ENTRY
4.1 1
0 8
0
8.0 ft2
0
0
0.4
0
12 SW=>NE Exterior Concrete Block - Int Insul-AUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.4
0
13 NE=>SW Exterior Concrete Block - Int Insd6REAT/DINT
4.1 26
0 8
0
208.0 ft2
0
0
0.4
0
14 NW=>SE Exterior Concrete Block - Int Ins2REAT/DINI
4.1 20
0 8
0
160.0 ft2
0
0
0.4
0
4/21/2020 10:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 8th Edition (2017) Compliant Software Page 3 of 5
.. FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space Cavity Width Height Sheathing Framing Solar Below
Ft W Ft In Ara RX-lue Ahso, 0
15 N=>S Garage Frame - Wood
KITCHEN 11 24 8 192.0 ft2 0.23 0.4
0
DOORS
# Omt
Door Type
Space Stones U-Value Width Height
Ft In Ft In
Area
1 SE=>NW
Insulated
ENTRY None .39 3 1 6 8
20.6 ft2
WINDOWS
Orientation shown is the entered orientation => chan ed to Worst Case.
_ / Wall
V # Ornt ID Frame
Panes
Overhang -
NFRC U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
1 NW=>SE 3 'Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW 13 Metal
5. NW=>SE14 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes 1.04 0.29 Y 32.9 ft2 1 ft 0In 1 ft 5 in Drapes/blinds
Yes 1.04 0.29 Y 6.9 ft- 1 It 0 in 1 ft 5 in None
Yes 1.04 0.29 Y 24.0 ft2 6 ft 0 in 1 ft 5 in None
Yes 1.04 0.29 Y 37.5 112 1 It 0 in 1 ft 5 in None
Yes 1.11 0.27 Y 40.0 ft2 8 ft 0 in 1 ft 5 in Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 315 ft2
315 ft2 24ft 8ft 11
INFILTRATION
# Scope Method
SLA CFM 50 EIA Egl-A ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356
1349.6 74.09 139.34 .1233 7
HEATING SYSTEM
# System Type
Subtype Speed Efficiency Capacity Block
Ducts
1 Electric Heat Pump/
Split Singl HSPF:8.5 34.8 kBtu/hr 1
sys#1
COOLING SYSTEM
# System Type
Subtype Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit!
Split Sing] SEER:15 34.8 kBtu/hr cfm 0.8 1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location EF Cap Use SetPnt Conservation
1 Electric
None
Garage 0.97 50 gal 60.9 gal 120 deg None
.
4/21/202010:27 AM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPI IT RI IMMA12V P14=e-I!1 leT 0C0f%0T
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # Company Name
System
Model #
Collector Model
#
Area Volume
FEF
None None
ft2
DUCTS
/ — Supply —
-- Return —
Air
CFM 25 CFM25
HVAC #
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT OUT QN
RLF
Heat Cool
1 Attic
6 175 ft2
Attic
65 ft2
Default Leakage .,
Attic _
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Coolin Jan Feb
VentinNov
g Jan Feb
Mar
Mar
rr Ap
Apr
€
May
rr
44Au
[[�]
Dec
Jun
Jul
[ Aug
(1
Sep Oct L�l
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
g 10
11
12
Cooling (WD) AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
78
78
78
78
78
78
78 78
78
78
Cooling (WEH) AM-
78
78
78
78
78
78
78
78
78 78
78
78
PM
78
78
78
78
78
78
78
78
78 78
78
78
Heating(WD) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
Heating (WEH) AM
66
66
66
66
fib
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 lbs/sq.ft.
0 ft2
0 ft
0.3
MASTER BEDROO
Default(81bs/sq.ft.
ft2
ft
0.3
WIC
Default(8 lbs/sq.ft.
ft2
ft
0.3
MASTER BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
M. BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
LAUDRY
Default(8 lbs/sq.ft.
ft2
it
0.3
BEDROOM'2
Default(8.lbs/sq.fL
ft2
ft
0.3
DINING/GREAT R
Default(8lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Defaull(B lbs/sq.ft.
ft2
ft
0.3
BATH
Default(8lbs/sq.ft.
ft2
ft
0.3
HALL
Default(8 lbs/sq.ft.
112
ft
0.3
FOYER
Defaull8lbs/s .ft.
ft2
ft
0.3
BEDROOM
4/21/2020 10:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR.
Street Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number.
Owner. WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
Y
w
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air baffler.
Breaks or joints in the air barrier shall be sealed.
not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
the insulation and any gaps in the air. barrier shall be sealed.
The insulation in any dropped ceiling/soffit
Access openings, drop down stairs or knee wall doors to
shall be aligned with the air barrier.
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be Insulated by completely filling the cavity
•
sealed.
Knee walls shall be sealed.
with a material having a thermal resistance of R-3
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be Insulated.
Floors
(including
The air barrier shall be installed at any exposed edge of
Insulation.
Floor framing cavity insulation shall be installed to
above -garage
maintain permanent contact with the underside of
and cantilevered
subfloor decking, or floor framing cavity insulation
floors)
shall be permitted to be in contact with the top side
of sheathing, or continuous Insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind nining and winno
Shower/tub
The air barter installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be Insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voidsnrinkler cover Hates and walls or celinns;
a. n, muvn, n,aywuon of iuy wens span uu in auouruance win me provisions or ild:-4uu.
4/21/2020 10:32 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX" = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
a) Supply duds R 6.0
2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0
3. No. of units (if multiple -family) 3. 1 c) AHU location Attic
4. Number of bedrooms
4.
2
5. Is this a worst case? (yes/no)
5.
Yes
6. Conditioned floor area (sq. ft.)
.6.
1446
7. Windows, type and area
a) U-factor:(weighted average)
7a.
1.060
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.284
c) Area
7c.
141.3
8. Skylights
a) U-factor.(weighted average)
8a.
NA
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
c) Concrete, raised (R-value)
9c.
10. Wall type and insulation:
A. Exterior.
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
10A1.
10A2. 4.1
10131. 11.0
10B2.
13. Cooling system:
Capacity34.8
a) Split system
SEER 15.0
b) Single package
SEER
c) Ground/water source
SEERICOP
d) Room unit/PTAC
EER
e) Other
14. Heating system: Capacity 34.8
a) Split system heat pump HSPF 8.5 .
b) Single package heat pump HSPF
c) Electric resistance COP
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0.97
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF_
f) Heat recovery unit HeatRec%
g) Other
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11 a. 30.0
b) Cross ventilation No
11b.
c) Whole house fan No
11c. 19.0
d) Multizone cooling credit
11d. No
e) Multizone heating credit
f) Programmable thermostat Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on Installed code compliant features.
Address of New Home: \Ci�\ r ¢ City/FL Zip: FT. PIERCE. FL �a��t 3
4/21/2020 10:32:17 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017)Compliant Software Page 1 of 1