Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
' FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: REVELS RESIDENCE Builder Name: PACE 2000, INC. SCANNED Street: 0 MOCO LANE Permk Office: ST LUCIE COUNTY BY City, State, Zip: FORT PIERCE, FL, Permit Number: Lucie COUT)b Owner: Jurisdiction: ST LUCIE COUNTY -St. Design Location: FL, FM Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or epsting New (From Plans) 9. Wall Types (2349.7 sqft.) Insulation Area 2. Singlefamilyor multiple family Single-family a. Concrete Block - EM Insul, Erderior R=4.1 2031.70 ft2 b. Frame- Wood, Adjacent R=11.0 318.00 ftz 3. Number of units, If multiple family 7 c. N/A R= fit! -4.-Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (2006.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 2006.00 ft2 6. Condi9bnecWoor,area above grade (M) 2006 b. N/A R= ft2 Conditioned floor area below grade (W) 0 c. R= ff 11. Ducts C� R tt 7. Windovs1321.1 sqft.) . Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 150 a. U-Factor: Sgl, U=0.56 129.00 ft2 SHGC: SHGC=0.24 -� *b. U-Factor: Sgl, U=0.69 96.00 ft2 12. Coding systems kBtufnr Efficiency SHGC: SHGC-0.22 a. Central Unit 35.2 SEER:16.00 c. U-Factor: Sgt. U=0.57 35.00 ft2 SHGC: SHGC-0.22 13. Heating systems kBtulhr Efficiency d. U-Factor: other (see details) 61.11 ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: other (see details) Area Weighted Average Overhang Depth: 1.500 ft. Area Weighted Average SHGC: 0.220 14. Hot water systems 8. Floor Types (2006.0 sgft.) Insulation Area a. Electric Cap: 50 gallons EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2006.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.160 Total Proposed Modified Loads: 64.85 PASS Total Baseline Loads: 71.03 I hereby certify that the plans and specifications covered by Review of the plans and FTHE S7- this calculation are in compliance with the Florida Energy specifications covered by this �� FO� Code. calculation indicates compliance _ y .r„�✓ �^^,� �^��n with the Florida Energy Code. ,, F nrrr,� x ,a• „ �O PREPARED BY: Before construction is completed a 0 DATE: 9-24-19 this building will be inspected for 1 6 All compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. y61 with the Florida Energy Code QOID 1yET4� OWNER/AGENT - BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. � eF► - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and t fVrSj an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).Q`�`! O�A O• `� V� o FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: REVELS RESIDENCE .Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2006 Lot It Owner Name: - Total Stories: 1 Block/Subdimsion: a#ofUnits: 1 Worst Case: No PlatBock: Builder Name: PACE 2000, INC. Rotate Angle: 0 Street: 0 MOCO LANE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE , Farnlly Type: Single-family FL, New/Epsting: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating- Design Dally Temp V Design Location TMY Site 97.5 / 2.5 k Winter Summer Degree Days Moisture Range FL, Fort Pierce FL—VERO—BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2D06 17769.2 ' SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil lD Finished Cooled Heated 1 BEDROOM3 188 1407.2 No 0 1 1 Yes Yes Yes 2 CLST 3, 22 198 No 0 1 Yes Yes Yes 3 BATH 2 55 495 No 0 1 Yes Yes Yes 4 CLST2 22 198 No 0 1 Yes Yes Yes 5 BEDROOM2 188 1692 No 0 1 1 Yes Yes Yes 6 HALLWAY 20 18D No 0 1 No Yes Yes 7 OFFICE 204 1836 No 0 - 1 Yes Yes Yes 8 KITCHEN/NOOK 287 2583 Yes 0 1 Yes Yes Yes 9 PANTRY 25 225 No 0 1 No Yes Yes 10 HALL 24 216 No 0 1 No Yes Yes 11 UTILITY 54 486 No 0 1 Yes Yes Yes 12 DINING 164 1476 No 0 1 Yes Yes Yes 13 FOYER 72 648 No 0 1 Yes Yes Yes 14 LIVING ROOM 196 1764 No 0 1 Yes Yes Yes 15 M WIC 63 567 No 0 1 Yes Yes Yes 16 MASTER BEDROO 234 21D6 No 0 1 1 Yes Yes Yes 17 M BATH 164 1476 No 0 1 Yes Yes Yes 18 MTOILET 24 216 No 0 1 Yes Yes Yes 924/201910:47 AM EnergyGaugeG USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS ag Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BEDROOM3 27ft 0 188 ft2 ____ 1 0 0 2SIab-On-Grade Edge Insulation CLST3 2It 0 22 ft2 -___ 1 0 0 3 Slab -On -Grade Edge Insulation BATH 2 5 It 0 55 tt2 ____ 1 0 0 4 Slab -On -Grade Edge Insulation CLST2 2ft 0 22 ft2 ____ 1 0 0 5SIab-On-Grade Edge Insulation BEDROOM2 12ft 0 188 ft2 1 0 0 6 Slab -On -Grade Edge Insulation HALLWAY- 1ft 0 20 ft2 ____ 1 0 0 7 Slab -On -Grade Edge lnsulabcn OFFICE 25ft 0 204 ft2 -- 1 0 0 B Slab -On -Grade Edge Insulation KITCHENMOOK 12ft 0 287 ft2 _-__ 1 0 0 9 Slab -On -Grade Edge Insulation PANTRY 1it 0 25 ft2 ____ 1 0 0 10Slab-On-Grade Edge Insulation HALL 1 ft 0 24 ft2 ____ 1 0 0 11SIab-On-Grade Edge Insulation UTILITY E ft 0 54 ft2 ---- 1 0 0 12Slab-On-Grade Edge Insulation DINING 18ft 0 164 ft2 ____ 1 0 0 13SIab-On-Grade Edge Insulation FOYER 8 ft 0 72 ft2 1 0 0 74SIab-On-Grade Edge Insulation LIVING ROOM 14 ft 0 196 ftz ---- 1 0 0 15SIab-On-Grade Edge Insulation M W IC 23 ft 0 63 ft2 _-_- 1 0 0 16SIab-On-Grade Edge Insulation MASTER BEDRO 23 ft 0 234 ft2 ____ 1 0 0 178Iab-On-Grade Edge Insulation M BATH 23 ft 0 164 ft2 --_- 1 0 0 18SIab-On-Grade Edge Insulation M TOILET loft 0 24 ft2 ____ 1 0 0 ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V S Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2243 ft2 0 ft2 Medium N 0.6 No 0.9 No 20 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2006ft2 N N 924PL019 10.47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) SEDROOM3 20 Blown 188 ft2 0.1 Wood 2 Under Attic (Unvented) CLST 3 20 Blown 22 ft2 0.1 Wood 3 Under Attic (Unvented) BATH 2 20 Blown 55 ft2 0.1 Wood 4 Under Attic (Unvented) CLST2 20 Blown 22 ft2 0.1 Wood 5 Under Attic(Unvented) BEDROOM 20 Blown 188 ff2 0.1 Wood 6 Under Attic (Unvented) HALLWAY 20 Blown 20 fI2 0.1 Wood 7 Under Attic (Unvented) OFFICE 20 Blown 204 fC2 0.1 Wood 8 Under Attic (Unvented) KITCHENINOOK 20 Blown 287 112 0.1. _ Wood 9 Under Attic(Unvented) PANTRY 20 Blown 25 ft2 0.1 Wood 10 Under Attic (Unvented) HALL 20 Blown 24 112 0.1 Wood 11 Under Attic (Unvented) UTILITY 20 Blown 54 ft2 0.1 Wood 12 Under Attic (Unvented) DINING 20 Blown 164 ft2 0.1 Wood 13 Under Attic (Unvented) FOYER 20 Blown 72,ft2 0.1 Wood 14 Under Attic (Unvented) LIVING ROOM 20 Blown 196 fI2 0.1 Wood 15 Under Attic (Unvented) MWIC 20 Blown 63 fI2 0.1 Wood 16 Under Attic (Unvented) MASTER BEDRO 20 Blown 234 ft2 0.1 Wood 17 Under Attic (Unvented) M BATH 20 Blown 164 ft2 0.1 Wood 18 Under Attic (Unvented) M TOILET 20 Blown 24 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 E Exterior Concrete Block - Ext InsiBEDROOM 3 4.1 12 0 9 4 112.0 ftz 0 0 0.6 0 2 S Exterior Concrete Block - Ext InsiBEDROOM 3 4.1 15 0 9 4 140.0 ft2 0 0.25 0.6 0 3 E Exterior Concrete Block - Ext Insul CLST 3 4.1 2 0 9 4 18.7 ft2 0 0.25 0.6 0 4 E Exterior Concrete Block - Ext Insul BATH 2 4.1 5 0 9 4 46.7 ft2 0 0.25 0.6 0 5 E Exterior Concrete Block - Ext Insul CLST 2 4.1 2 0 9 4 18.7 ft2 0 0.25 0.6 0 6 E Exterior Concrete Block - Ext InsiBEDROOM 2 4.1 12 0 9 4 112.0112 0 0 0.6 0 7 N Garage Frame - Wood BEDROOM2 11 15 0 9 4 140.0 its 0 0.25 0.6 0 8 S Exterior Concrete Block- Ext Insul OFFICE 4.1 12 0 9 4 112.0 ftz 0 0 0.6 0 9 W Exterior Concrete Block- Ext Insul OFFICE 4.1 13 0 9 4 121.3 ft2 0 0 0.6 0 10 S Exterior Concrete Block- Ext InsigITCHENINO 4.1 6 0 10 0 60.0 fI2 0 0 0.6 0 11 W Exterior Concrete Block - Ext InsNITCHENRdO 4.1 6 0 10 0 60.0 fI2 0 0 0.6 0 12 N Garage Frame - Wood KITCHEN/NO 11 1 0 10 0 10.0 ft2 0 0.25 0.6 0 13 N Garage Frame- Wood PANTRY 11 5 0 9 4 46.7 ft2 0 0.25 0.6 0 14 E Garage Frame- Wood HALL 11 4 0 9 4 37.3 ft2 0 0.25 0.6 0 15 N Exterior Concrete Block - Ext Insul UTILITY 4.1 6 0 9 4 56.0 ft2 0 0 0.6 0 _16 E Garage Frame - Wood UTILITY 11 9 0 9 4 84.0 ft2 0 0.25 0.6 0 17 N Exterior Concrete Block - Ext Insul DINING 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 18 E Exterior Concrete Block - Ext Insul DINING 4.1 1 0 10 0 10.0 fI2 0 0 0.6 0 _19 W Exterior Concrete Block -Ext Insul DINING 4.1 5 0 10 0 50.0 ft2 0 0 0.6 0 20 N Exterior Concrete Block - Ext Insul FOYER 4.1 8 0 10 0 80.0 fI2 0 0 0.6 0 21 S Exterior Concrete Block - Ext InsdtIVING ROO 4.1 14 0 11 0 154.0 112 0 0 0.6 0 22 E Exterior Concrete Bloch - Ext Insul M W IC 4.1 5 0 9 4 46.7 ft2 0 0 0.6 0 924201910:47 AM EnergyGaugeg USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 Ix C a W UJ i V W 2 U H a z rn N Lb It s Q LL ° 0 0 0 0 0 0 0 0 0 Z Z Z ffi ffi Z Z Z Z Z Z Z ffi ffi ¢ N W W W W W O�c O ro O t0 O m O ro O m O fo O f0 'O t0 O N m m N c O fll E ' m 'S t U O z O z O Z yy�� a C'0 O Z O Z O Z O Z O Z O Z O Z O O O O O O O O O = �., C 10 tT 1i u O cl 0 O c O O O O O O O O O 0US ' 3 0 0 0 0 t y 0 0 0 0 0 0 0 0 0 0 m NN L C C c c C C C c C C c c c c U 6 f0 f0 �O tD f0 tp f0 t0 f0 f0 t0 f0 t0 f0 Ol > °r; E E C k "z r Z: 3 � t V V O < V V C C = m ¢ O a O O O 0 O O � O O O O O O1 _ c m N te Q N � 0W N O m � N N N N Q 0 0 0 0 0 0 0 0 0 E E - z z Z Z Z z z z z Z Z Z Z z ffi t S L7 Z E J3 U N Ol U Oi Y ro ¢ N a` 3 y N N N N N O _ O' Q y = O O O O O N O O N O N O N N N N 0 O 0 oC 3 m E a a a v a a v v v£ N r v va u°i L7 g U' N LL O O O O O O O C O 0 0 0 0 0 3 Q. w m U U¢¢ F F F w .w_.i w a 3 3 ¢m m m o o o en 2 2 U ¢ m Z C c c c c C c c c c_ N O � S2 S2 — w w w w w w w w w w w w w w w w m m m m m m m m m m m m m m 'ffi rn rn rn rn m m rn rn m m m m m m O m m m m m m F' m LL w w w w w w w w w w w w w w ffi U 3 0 N v f0 N m N N N Q Ti w Tc w w if ii ii S7 i7 w w w W W m w w w 3 m 3 Z Z Z w 3 z 3 m 3 w 3 z w 3 z 3 NI NI NI NI NI NI ml pJl t+ll I � I . A C UC N E U FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000394 2073.1 113.81 214.03 .1422 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 35.2 kBtwhr 1056 dm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None nz DUCTS / — Supply— V # Location R-Value Area ---- Return— Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 150 ft2 Attic 15 ftz Default Leakage Attic (Default) c(Default) c 1 1 TEMPERATURES ProgramableE�Thermostat:Jan Heating�]JN Febj[ ]] l 1 Jan l J Feb lxJ � C[Apr[eilliing Fans:Cooling [Jun[ Jul [[X]J 4XJ) jSep] Apr l 1 Y l Jun [ ] Jul l 1 Aug l 1 Sep lxl Oct 1A Noovv Dec [[ [ Decec 92412019 10:47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WO) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0ft2 Oft 0.3 BEDROOM4 Default(8 lbs/sq.ft. ft2 It 0.3 CLST4 Default(8 lbs/sq.ft. f12 it 0.3 BATH 3 Default(81bs/sq.ft. f12 ft 0.3 BEDROOM3 Default(81bs/sq.ft. ft2 If 0.3 CLST3 Default(8 lbs/sq.ft. fie It 0.3 BATH 2 Defau@(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM2 Default(8 lbs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 lbs/sq.ft. ft2 ft 0.3 MUD ROOM Default(8 lbs/sq.ft. ft2 It 0.3 AHUCLST Default(8 lbs/sq.ft. ft2 It 0.3 DINING Default(8 lbs/sq.ft. ft2 ft 0.3 FOYER Default(8 lbs/sq.ft. IF ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 It 0.3 LIVING ROOM Default(8 lbs/sq.ft. ft2 ft 0.3 FAMILY ROOM DefauH(8 lbs/sq.ft. ft2 It 0.3 HALL Defmft(8 lbs/sq.ft. f12 ft 0.3 HALL2 Default(8 lbs/sq.ft. fI2 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft2 It 0.3 M W IC 1 Default(8 lbs/sq.ft. fP It 0.3 M WIC 2 Default(8 lbs/sq.ft. ft2 ft 0.3 MBATH Default(8 lbs/sq.ft. ft2 It 0.3 M TOILET Default(8 lbs/sq.ft. ft2 ft 0.3 WAD Defau@(8lbs/sq.ft. ft2 ft 0.3 POWDERRM Default 81bs/s .ft, f12 ft 0.3 GAME ROOM 924/201910:47 AM EnergyGaugea USA 6,0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF. 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 91 The lower the Energy Performance Index, the more efficient the home 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 35.2 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2006 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a 0.557 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.220 14. Heating system: Capacity 27.0 c) Area 7c. 321.1 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 20.0 b) Cross ventilation No b) Single assembly 11 b, c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit 0 Programmable thermostat No 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: 0 MOCO LANE City/FL Zip: _ FORT PIERCE, FL 924201910:48:13 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF. Project Summar Job: wri9 htsoft' Entire House Byte: JuI05, zo,e QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 77246&6796 Enoil: OUICKCALCS@AOL.COM Proiect Information For: REVELS RESIDENCE, PACE 2000, INC. SCANNED 0 MOCO LANE, FORT PIERCE, FL BY Notes: St. udeCounty Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 23562 Btuh Structure 17790 Btuh Ducts 5996 Btuh Ducts 8583 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none e) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 29558 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment'sensible load 25054 Btuh Method simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3682 Btuh Ducts 2347 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg (none) Area (ft2) 2006 2006 Equipment latent load 6029 Btuh Volume (fta) 19589 19589 Airchangeslhour 0.32 0.16 EqulpmentTotal Load (Sen+Lat) 31083 Btuh Equiv. AVF (cfm) 104 52 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR6036J1 AHRI ref Coil TEM4AOC37S31++TDR AHRI ref 201763705 Efficiency 80AFUE Efficiency 13.0 EER, 16 SEER Heating input 0 kW Sensible Cooling 24640 Btuh Heating output 0 Btuh Latent cooling 10560 Btuh Temperature rise 0 OF Total cooling 35200 Btuh Actual air flow 1173 cfm Actual air flow 1173 cfm Air flow factor 0.040 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �. wrights ft- 2019Jul-0510:11:11 RightSufte® Universal 2019 19.0.08 RSU08101 Page 1 �'� E:\Docunnets\Wrightsoft HVAC\REVELS RESIDENCE.rup Cale = MA Front Door faces: N I wrightsofr Right-JO Worksheet Job: Date: Jul 05, 2019 Entire House By: QUICK CALCS, INC. 317 STLUCIE LANE, FORT PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466-6796 Emal OUICKCALCSOAOLCOM 1 2 3 4 5 Room name Bposed wall Room height Room dimensions Room area Entire House 210.0 ft 9.8 It 2006.0 ft' BEDROOM 3 27.0 ft 9.3 ft heallcool 1.0 x 188.0 It 188.0 ft- Ty Construction number U-value (Btuhgt-F) Or HTM (Btu" Area (ft2) or Whaler (ft) Load (Bluh) Area (ft-) or perimeter (ft) Load (Btuh) Heat I Cool Gross WP/S Heat Cool Grass N/P/S Heat Cool 6 11 3A 1-flocs - 2 glazing cir love 2 glazing cir lave_ 2 glazing drlow-e 2glazing dr law-e 11D0 _.._-_.__.-_ 13A-4ocs 2glazing, cir low-e 2 glazing clr, low p. 13A-4ocs 2glazing cir low-e 2glazig cir lox-e 2 glazing, cir low-e 2glazng.clr.low-e__._ 2glazirg, cir low-e 2 g1mi g, 2 glazing, cir low-e 2 glazing, cir low-e 2 glazirq, cir low_e� 22A-tph .0.143 0.400 - 0.400 0.400 0.400 -.-0.3W 0.143 0.400 0 400 0.143 0.400 0.400 0.400 ___0.400 0.143 0.400 0.400 0.400 __0.400 ,_ 0.032 1.358 h n n - n n _.n_ a a _e_ - s s s s .s__._.11.20-_6.93-_.24._.____.48..-_.__..269-166-_0.__-.„_0 w w w w w _e.400 1120 `'-11 20 1120 1120 _.�1092 4.00 11.20 _11 20 4.00 11.20 11.20 11.20 4.20 1120 11.20 11.20 _1129 w 0.90 38.02 ..-2.19 10.19 - 10.19 10.19 7.93 _v 10.34 2.19 25.22 25.22 2.19 10.19 10.19 10.19 .377 6 -2D 13 12 -"-_305 0 -"' 0 0 0 __-.1222 67 -`" 224 150 134 �- ___668 61 - ---204 137 95 ---208 944 303 _ 454 - 9M 153 245 979 _...___0 -0 . - -' -0 0 0 -----0 112 0 0 ! 140 0 24 0 .-.- 0.. 0' 0 0- 0 -__,-0 112 0 0 116 0 24' 0 ------o 0 - -"-0 0 0 .._�.._.. 0 447 0 _ 0 _ 462 0 269 0 _,..____0_ 0 0 0 0 0 --..-- 68 1027 - :70 0 _--0 0 0 _..._..._0 244 0 0 -'�' 253 0 245 0 -,__....0 0 0 0 0 0 _421 0 ylY _-_..20 461 12 18 586 15 24 96 .-20 431 0 _0 427 30 48 192 ._..__219 1727 134 202 1710 168 269 1075 L�GG 1�1 I---G I`-GG-G � 2.22 25.22 18.70 18.70 15.16 -2.24 0.00 615 15 36 12 18 .w_. 2006 2006 520 0 0 0 0 2006 210 2168 403 134 134 200 _ .�1797 7985 1141 378 224 224 271 __ _ _ 4493 0 0 0 0 0 0 _ 188 188 0 0 0 0 0 188 27 F ^� _ - 61 c) AED excursion 64 -62 Ernslope loss/gain 20847 13028 ` 2373 1100 12 a) Infiltration b) Room ventilation 3215 0 861 0 398 0 107 0 13 Internal gains: Occupants Q 230 Appliances/other 0 0 3900 0 0 100 Subtotal pines 6 to 13) 23562 17790 2772 1307 14 15 Less Wernal load Less transfer Redistribution Subtotal Duct loads 25% 48% o 0 0 23562 5996 0 0 0 17790 8583 259/6 48% 0 0 112 2884 734 0 0 60 1367 660 Total room load Air required (cfm) 29558 1173 26372 1173 3618 144 2027 90 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Ad- 2019Jul-0510:11:11 Ask RightSuSe® UnWersal 2019 19.0.08 RS1J08101 Page 1 EADocunnets\Wrightsoft HVAC\REVELS RESIDENCE.mp Cato =MJS From Door faces: N wrightsoft Right-M Worksheet Job: Date: Jul 05, 2019 Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOLCOM 1 2 3 4 5 Room name Egosed wall Room height Room dimensions Room area CLST 3 20 It 9.3 ft heallcool 11.0 x 20 It 220 ft2 BATH 2 5.0 ft 9.3 ft heat/cool 11.0 x 5.0 it 55.0 ft2 Ty Construction number U-v-alue (Bhm/fta°F) Or HTM (BtuhRt� Area (ft2) a perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 11 13A-466s 2 glazing clr low a 2 glazing clr low e- 2 glazing clr low a 2 glazing clr lowe 11D0__-__"_ s 2 glazing, clr Irnv-e 2 gluing, 2 clazin a, clr low_e- 13A-4ocs 2 glazing, clr law-e 2 glazing, er low-e 2glazirg, clr low-e 2 glazing,.clr.lrnve_ 2 glazing, clr low-e 2 glazing, 2 glazing, clr lowe 2 glazing, clr low-e 2glazing, clr low_e _...__ 0.143 0.400 0.400 0.400 0.400 __.0.390 0.400 0.400 -_ ___0.400 0.143 0.400 0.400 0.400 -0.400 0.400 0.400 0.400 0.400 0.400 _ 1.358 n n -n n n _n___10.92_._10.34. a a ._ e- a s s s -a- w w w w _w_ - 400 11.20 - -1120 11.20 11.20 4.20 1120 __ _11.20 4.00 11.20 11.20 11.20 -11.20 4.20 11.20 11.20 11.20 11.20 38.02 2.19 10.19 10.19 10.19 7.93 5.22 25.22 25.22 2.19 10.19 10.19 10.19 - 6.93___.._,..0._____0,._..__0 2.22 25.22 25.22 18 18.7070 .. 15.16 -,_2.24 0.00 _. ___-0 0 -0 0 0 _.0..0__.. 19 0 - -_-0 0 0 0 0 0 0 0 0 ___..._ 0 _ _._ 22 22 0--0 0 "0 0 0 19 0 --0 0 0 0 0 0 0 0 0 ____ 0.� _.22 2 0 - 0 0 0 __-0 74 0 _.._y0 -0 0 0 0 0 0 0 0 0 �._ RO 76 0__.__".0_ 0 - 0 0 0 _ ....._0_ 41 0 0 ..-..___0 0 0 0 ---0 0 0 0 0 -_�_ 0 _ _ _ ...._49 _ 0. 0 0 0 0 _.__:0-. 47 12 _ 0 ..___ 0._.___.._0 0 0 0 ------0 0 0 0 0 0 ._ _. __55 55 `_.__0 0 - - -0 0 0 -...__ _0 35 0 0 0 0 0 0.._.__-_.0 0 0 0 0 -._ 0_.. -__ _ 55 5 _ 0 0 "' '0 0 0 ____ __8 138 134 --- _ 0 0 0 0 0 0 0 0 0 0 _ _ ._._49 190 0 0 -' - 0 0 0 - "_ .__0 75 303 -.---,-0 0 0 0 0 __..___0 0 0 0 0 .. 0 "-. _ _123 _ 0 _ ly II----GG . _. 1� �--G I--G III���--------- _ - FtPh� 6 c)AED elcunsion -4 a Envelope loss/gain 170 66 512 498 12 a) Infiltration b) Room ventilation 30 0 8 0 74 0 20 0 13 Internal gains: Occupants B 230 Appliances/other 0 0 0 0 0 0 Subtotal pines 6 to 13) _ 200 93 566 518 14 15 Less eMemal load Less transfer Redistribution Subtotal Duct loads 25% 48% 0 0 -200 0 0 0 0 -93 0 0 25% 48% 0 0 188 774 197 0 0 98 615 297 Total roan load Air required (cfm) 0 0 0 0 971 39 912 41 Calculations approved bvACCA to meet all requirements of Manual J Bth Ed. ,� -R++- wrlgtilsoR- 2019Jul-0510:11:11 �A RlghtSulle® Universal 2019 19.0.08 RSUG8101 Page 2 E:\Docuanets\Wrightsoft HVAC\REVELS RESIDENCErup Cale =MJ8 Front Door faces: N wrightsofC Right-JO Worksheet Job: Entire House Date: Jul 05, 2019 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCSQAOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area CLST 2 20 it 9.3 it heat1cool 11.0 x 20 ft 220 1? BEDROOM 2 12-0 it 9.3 ft heat/cool 1.0 x 188.0 it 188.0 ft2 Ty Construction number U-value (BtuhRti'F) Or HTM (EuNft9 Area (ftz) a perimeter (ft) Load (Ruh) Arm (ft2) or perimeter (ft) Load (Ruh) Heat C-001 Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 .__ ' _ _11D0 4}r II----GG _- 4� I----G Ill----GGG Vtl ��l(-CCCC F 13A4ocs - 2 glazing clr low-e 2glazing clr low-e 2 glazing, cir low-e 2 glazing cir low-e 13A-4ocs 2 glazing, clr bwv a 2 glazinq, clr low-e_ 13A-4bcs 2glazing, clr low-e 2glazing, clr low-e 2 glazing, clr low-e 2glazirg, ch.low-e- _ 13A-0gcs 2glazing, clr le 2 glazing, cir low-ow-e 2 glazing, cir law-e 2 glazmo. clr low=e� 16A30ad._.... 22A-tph 0.143 0.400 0.400 0.400 0.400 0.390._n___.1092__10.34 0.143 0.400 _ _,-_0.400 0.143 0.400 0.400 0.400 _._ _0.400 0.143 0.400 0.400 0.400 __.._0.400 0.032 1.358 n n n n n a a _a_ s s s s -_a_ w w w w w _.._._ - __.400 _ 11.20) 1120 11.20 11.20 4.00 11.20 -_11.20 4.00 11.20 11.20 11.20 ".-_.._11.20 --2.19 10.19 10.19 10.19 7.93 2.19 25.22 _25.22 2.19.V.�-0'J 10.19 10.19 10.19 __._6.93 _ -_ 0 0 0 0 0 ._0 19 0 0 . _0 0 -0 0 0 0_._.-0__ 19 0 0 __.__0 0 0 0 ______0 -0--- 0 - - 0 0 0 74 0 0 ..____.0 0 0 0 ,._ -0 0 0 - ' ""0 0 0 __0__ 41 0 0 ...___. 0-.0-0- 0 0 0 _-__0 0._0 0 - 0 0 0 _-_0 112 0 18 0 0 0 ___ _ _ _0 0 0 0 D -___ 0 ._.__ 188 188 0 -0 0 0 ____0__._. 94 0 0 0 0 0 __-._0 0 0 0 o ___ �._. 0 .... 788..__. 12 .._ _ ..0 0 - 0 0 0 _0 375 0 202 0 0 0 0 _- _ 0 0 0 0 0 _ ___. 0 -168 456 0 0 - `" 0 0 0 _ .._0 205 0 454 0 0 0 0 ._ _ __ 0 0 0 0 0 __.. _ 0 __.._ 421 0 0 0 0 __-_-0 4.. 11.2020 11.20 11.20 1120 0.90 3B.02 25.22 22 25.22 1818.7070 15.16 _--2.24 0.00 0 0 0 0 _.. _ 0 22 22 0 0 0 0 __ 0 _.22 2 0 0 0 0 0 .__20 76 0 0 0 0 ____._ 0 ___ _ 49 0 6 c)AED excursion -4 SO Ernelope loss/gain 170 86 1201 1050 12 a) Wiltratim b) Room ventilation 30 1 0 8 0 177 0 47 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 300 Subtotal pines 6 to 13) 200 93 1378 1398 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 25% 40% 0 0 -200 0 0 0 0 -93 0 0 25% 4891 0 0 112 1490 379 0 0 60 1458 703 Total roan load Air required (cfm) I 0 1 0 0 0 1870 74 2161 96 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ,e � wrl_9ti�o6fY 2019-Jul-0510:11:11 C&M Right-Sufte® Universal 2019 19.0.08 RSUGS101 Page 3 EADucunnets\Wrightsoft HVAC\REVELS RESIDENCE.rup Cale =MJ8 From Door faces: N + wrightsoft° Right-J0 Worksheet Job: Entire House pate: Jul 05, zo,s By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466.6799 Fax 772-466-6796 Email: OUICKCALCS@AOLCOM 1 2 3 4 5 Room name E1glosed wall Room height Room dimensions Room area HALLWAY 0 ft 9.3 It heat/cool 4.0 x 5.0 ft 20.0 ft- OFFICE 25.0 ft 9.3 ft heat/ood 120 x 17.0 ft 204.0 f? TY Construction number U-value (BtuMt-'F) Or HTM (Btuh/ft-) Area (ft2) or perimeter (ft) Load (Btuh) Area OM a perimeter (ft) Load (Etuh) Heat Cool Gross WP/S Heat Ccol Gross N/P/S Heat Cool 6 17 -_. �-. ____-.. �._... .13A-flocs 2 glazing, clr low-e .2-glazing,-clr,oWe_ 2 glazing clr lcw-e 2gluing dr lode 13A-4ocs 2 glazing, clr low-e 2 glazing _dr Iw:e__ 2glazing. 2inclr low-e 2 glazing, olr low-e 2 glazing, clr low-e 2 glazing, clrlm-.e._ 13A-40es 2 glazing, dr lox-e 2 glazing, dr low-s 2 glazing, clr low-e 2 glazinq, dr low-e� _16A�OadY______.._ � 22A-tph .-'-- 0.143 0400 _. 0.400 0.400 0.400 __0.390 0.143 0.400 ---0.400 �LL0.400 0.400 0.400 0.400 ---0.400 0.143 0.400 0.400 0.400 0.400 _� 0.032 1.358 - .n.. n n- n in _n_ a a _,a s 6 s s _s_ w w w w w ^- _ - „. .___ 4.00 11� -11 29 1120 1120 -1092 4.00 11.20 .� 11.20 420 11.20 11.20 11.20 ._.. 11.20 4.00 11.20 11.20 11.20 11.20 090 38.02 `_� 239 1019, 0 0 _Y -0 0 _....__.-. _0 0 0 0 __..v.0�..0: 0 0 0 0 _ 0 0 - 10�19 10.19 7.93 __,.-10.34 219 25.22 �25.22 0.19' 10.19 10.19 10.19 __6.93 2.19 25.22 25.22 18.70 15.16 ,_224 0.00 - --0 0 0 -.-0 0 0 �0 0 0. 0 0 _._0 0 0 0 0 0 �� 20 20 -- 0 0 0 ___-0 --._ 0 0 '0 _, ..-__0 0 0 ,„__.,_p 0 0 0 0 __0 0 0 0 0 0 -,_.�,�18 0 .. ---0 0 0 . _- ._._.0 0 0 _.___-__0 0 0 0 0 ----.0 0 0 0 0 0.__...__.- - .-`0 0 0 . _ _ _-0 0 0 0 - -'0 0 0 ---,0 0 0 --- 0 88- 0 0 01 _. 24.-.259 -- _ 0 0 0 --__0 0 0 0 351 0 0 0 413 0 0 0 200 T�183 _ 951 0 0 .___,-...0 0 0 0 0 ----_0 0 0 0 0 --_0 0 0 0 0 0 - 20 __- 0 110 0 0 0 - 24. 121 0 0 0 18 __.204 204 -a_.�__0 190 0 0 .0 --.166 225 0 0 0 271 0 103 0 0 0 _ _,_^,___0 _._204 _ 25 F �5 .�,_ 4 0 6 c) AED excursion -2 59 Envelope loss/gain 18 43 2366 13M 12 a) Nfiltration b) Room ventilation 0 0 0 0 369 0 99 0 13 Internal gains: Oocupards 44 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 18 43 2734 1469 14 15 Less Memel load Less transfer Redistribution Subtotal Duct loads 25% 489/6 0 0 -18 0 0 0 0 ' -43 0 0 250/6 480/6 0 0 3 2737 697 0 0 7 1476 712 Total room load Air required (rim) 0 0 0 0 3434 136 2189 97 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. .L -rP- wrYghtso_Y - 2019Jul-Jul10:11:11 RlghtSuite® Universal 2019 19.0.08 RSUG8101 Page 4 EADocurmets\Wrightson HVAC\REVELS RESIDENCE.rup Cale =MJ8 From Door faces: N wrightsoft° Right-J@ Worksheet Job: Entire House pate: Jul 05, 2019 By: QUICK CALCS, INC. 317 ST LLICIE LANE, FORT PIERCE, FL 34946 Phone: 772-466.6799 Fax 772-466-6796 Email: OUICKCALCS@AOLCOM 1 Room name WCHEN/NOOK PANTRY 2 Fposed wall 120 it 0 It 3 Room height 10.0 it teattcool 9.3 it heaUcocl 4 5 Room dimensions Room area 1.0 x 297.0 It 287.0 ft2 5.0 x 5.0 It 25.0 ft2 Ty Construction U-value Or HTM Area (fF) Load Area (ft2) Load number (Btuhlftz F) (Bh hjt2) a perimeter (ft) (Btuh) or perimeter (it) (Btuh) Heat Cod Gross N/P/S Heat C001 Gross N/P/S Heat Cool 6 13A4ocs _... - 2 glazing, clr low-e - 2 gluing, clr low-e _. 0.143 0.4100..n 0.400 if" - n 4.00 _. 11.20. 11.20 ----2.11 10.19 10.19 _ _ . 0 _ _ 0 0 __ 0 _ 0 0 - _ 0 0.,_ 0 - _ 0 0 0 . _.0 0 - 0 _0 0 - 0 0 0 - - '0 0 0 - 0 11 2 glazing, clr law-e 2 glazing, clr low-e 0.400 0.400 n n 11.20 11.20 10.19 7.93 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 .__ IL-GG _11D0- __._ _.._ _ 13A-4yl 2glazi g, 2 glazing, clr low-e _ _0.390 0.400 0.400 --n. a a _ 10.92 4.20 11.20 __. 10.34 219 25.22 _ ____ _0 0 0 0 0 0 0 _._0 0 0 ___ 0 0 0 _.. 0 0 0 _... _ 0 0 0 - _ 0 0 0 _ 44��II 2elazirc, drlav-e 13A-4ccs_ _ 0.400 -�0.143 _ e 5 _11.20_25.22 4.00 2-19 0 _ _ -._60 0 _ _ 0 - -' 180 0 _- 98 0 0 0 _0 _ ___0 0 _ _o . 0 .__.__ 45 f---G II`----GGG 2 gluing, clr Im-e 2glazirg, clr low-e 2gluing, clr lox-e 0.400 0.400 0.400 s s s 11.20 11.20 11.20 10.19 10.19 10.19 15 0 0 15 0 0 168 0 0 153 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _ 2 glazing,-ciclaue ___ _0.400-.s-.__11.20 _ 6.93 0 .___._. 0____-_.0_- ___0._. __.,_0-______0 ___.,_0.. .._.0 0.400 w 4.00 2.22 60 45 160 98 0 0 0 0 2 glazing, Or lox-e 2 glazing, 2 glazing, Or low-e 2 glazing, clr lax-e 0.400 0.400 0.400 w w w 11.20 11.20 11.20 25.22 18.70 18.70 15 0 0 0 0 0 160 0 0 370 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -_ _. C. __,16A30atl__.__._.. 2 cluiq, clr lox_e 0.400 ._0.032_.___.0.90._._,2.24__-., w--__11.20__15.16_ 0__- 287-.___287___.�7257 0 _, 0__ 0- __...643 _0 . 25. _-_._0 .25 0 __. __..22 __0 _.__.56 F _._ 22Atph.1?358-___38_02_ 0.00_ 297 12 456._0 __. 25 _0 -0 ----- -- 0. 6 c) AED excursion 12 -3 Envelope loss/gain 1410 13M 22 53 12 a) Wiltration 190 51 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1400 0 Subtotal (tines 6 to 13) 1600 2834 22 53 Less e#emal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 10 24 0 0 14 Subtotal 1610 2858 22 63 15 Duct loads 25% 481/6 410 1379 259/6 481% 6 26 Total room Iced 2020 4236 28 79 Air squired (efm) 80 188 1 4 Calculations approved byACCA to meet all requirements of Manual J Sth Ed. ,C -rk- ,=rv9ft�.� 2019Jul-Jul10:11:11 �cA \REV LS R SIDEUnivecal 2DI.rup Cale 8 RS1106 Front Page 5 E:\Dacurtnets\WrlgMsofl HVAC\REVELS RESIDENCE.mp Cale = MJ6 Front Door faces: N +wrightsaft' Right-J® Worksheet Job: Date: Jul 05, 2019 Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: OUICKCALCS@AOL.COM 1 2 3 4 5 Rcom name Bposed wall Room height Room dmensios Room area HALL 0 ft 9.3 ft heaUcool 6.0 x 4.0 ft 24.0 ft' - UTILITY 6.0 it 9.3 it heat1cocl 6.0 x 9.0 ft 54.0 ft' TY Construction number U-value (8tuh/ftz°F) Or HTM (BbMt2) Area (ft2) a perimeter (ft) Load (Btuh) Area (ft2) a perimeter (ft) Load (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cod 6 11 13AAWS 2 glazing clr [=-e 2 glazing eIr low-e 2 glazing clr low a 2glazing clr low-e 11D0 ._.. ._._. _ 13A-4ocs 2 glazing, clr low-e 2o0az1no, clrlawe.__ 13A-4acs 2 glazing, clr low-e 2 glazing, clrlow-e 2 glazing, clr low-e 2glazi g, ciclow-e_- 2 glazing, clr I w-e 2 glazing, 2 glazing, cIr low-e 2 glazing, clr Ivv-8 2 glazirlq, clr lm-e _ __ 16A30ad`_ 22A-tph __ _ 0.143 0.400 0.400 0.400 0.400 0.390_,n_-_10.92 0.143 0.400 _-0.4D0 0.143 0.400 0.400 0.400 ---0.400 0.400 0.400 0.400 0.400 __ _ _0.400 �._0.032 1.358 Ir . n- In In11 In a a __e_ s s s s _s_ w w w w _w_ _- - _ 400 - .11 20 11.20 20 1120 4.00 11.20 _,11.20 4.00 11.20 11.20 11.20 __.11.2) 4.2) 11.2) 11.20 11.20 _ _ 11.20 _. _ 0.90 38.02 2.19 . 10.19 10.19 10.19 7.93 �10.34 219 25.22 25.22 2.19 10.19 10A9 10.19 __,6.93 2.22 25.22 25.22 18 18.7070 15.16 2.24 0.00 -0 - . _0 - 0 0 0 ,_ _-_0.___ 0 0 -____0 0- 0 0 0 __-0 0 0 0 0 _ _ 0 ___ --24 24 _0 0 - 0 0 0 __0_ 0 0 0 __ _...0 0 0 0 -__ _0 0 0 0 0 __ _ 0 _ _24 0 __ _ 0 _ 0 0 0 0 ___0 0 0 0 ---0 0 0 0 __w__0 0 0 0 0 0 __.r 22 ._ -_ 0 0 0 - -0 0 0 _0 0 0 0 -.� '0- 0 0 0 -__0 0 0 0 0 0 _ _54 _ 0- -56 6 . - - - 0 0 0 _0 0 0 0 _ _0-__0 0 0 0 _ . __.__0 0 0 0 0 _ _ 0 __._54 _ `� _. _50. 0 - - -0 0 0 _. _-0_____00 0 0 0 0 0 0 _-0 0 0 0 0 0 -__-,54 __ 6 _ 199 67 - ---0 0 0 0 0 0 _. 0_0 0 0 0 _-.___0 0 0 0 0 0 _- 8 .-4 _._ 228 ..---109 61 0 0 0 0 0 0 0 0 0 _.____0 0 0 0 0 _ 0 = 121 �G _ .C._.__ F ._ _ 6 c)AlD elxursion -2 37 Envelope loss/gain 22 51 543 254 12 a) infiltration b) Room ventilation 0 0 0 0 89 0 24 0 13 Internal gains: Occupants @ 230 Appliarxe:s/other 0 0 0 0 0 500 Subtotal Pines 6 to 13) 22 51 632 778 14 15 Less eltemal load Less transfer Redistribution Subtotal Duct loads 259/6 48% 0 0 -22 0 0 0 0 -51 0 0 25% 4W.1163 0 0 8 640 0 0 19 797 384 Tote) room load Air requ'ted (cfm) 0 0 0 0 803 32 1181 53 Calculations approved bvACCA to meet all reauirements of Manual J 8th Ed ,� - - 2019.NI-0510:11:11 .& RlghtSute® Universal 2019 19.0.08 RSLIC8101 Page 6 EADocuonets\Wnghtsoa HVAC\REVELS RESIDENCEmp Cale =MJ8 Front Door faces: N PF wrightsofC Right-JO Worksheet Job: Entire House Date: Jul 05, 2019 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax 772466.6796 Email: OUICKCALCS@AOL.COM 1 Room dame DINNG FOYER 2 67xsed wall 18.0 It 8.0 it 3 Room height 10.0 ft heaUcool 10.0 ft heaNcool 4 5 Room dimensions Room area 1.0 x 164.0 ft 164.0 ft' 8.0 x 9.0 ft 720 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btufdhi'F) (ai,"t2) or perimeter (it) (Btuh) a perimeter (ft) (Btuh) Heat cool Gross WP/S Heat cool Gross WP/S Heat cool 6 13A-4ocs -_ 2 glazing, -clrlow-e- 2 glazing, dr low-e - 0.143 0.400 0.400 n n n 4.00 - 11.20 11.20 2A9 10.19 10.19 --- 12D ., _ 0 20 100 _ 0 0 - - 400 _ 0 224 ---219 - _ 0 204 - -- -80 _ _ 0 0 _ -- 46 0 0 - -18-6 0 -- - -0 102 0 - 0 11 2 glazing, clr lox-e 2 glazing, clr lox-e 0.400 0.400 n n 11.20 11.20 10.19 7.93 0 0 0 0 0 0 0 0 13 0 0 0 150 0 137 0 11 DO__ _ ___- 13A-4acs 2 glazing, clr low-e _ .0.390 0.143 0.400 _n_ a a _ 10.92 4.00 11.20 __10.34 219 25.22 ___ _ 0 10 0 .._ _ 0 10 0 ____ 0 40 0 _. 0 22 0 _. _ _20 0 0 _. .20 0 0 _219 0 0 _ 208 0 0 lQl- `EGG 2 glazinxl. dr lw e__ 3A-0pcs _0.400 0. _e_ s _ _11.20 4. 25.22 2.19 _ _-_0 0 0 0 _-0 0 _0 0 -__0 0 -,_ _0 0 _-__0 0 _ _. _ __0 0 2 2 glazing, clr lave 2 glazing, r low-e 2 glazing, clr lox-e d 0.400400 0.400 0.400 s s s 11.2020 11.20 11.20 10.19 10.19 10.19 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ---G 2g1azulg,.c1r.lave _ ____0.400_s_ _. 11.20 __. 6.93 __.___ 0_,.-.-._0 ____-_0_ __-_0 __.__0._. ._.__0_.._ ..0 ._..__0 13AU+/ 0.400 w 4.20 50 50 200 100 0 0 0 0 2gla4acs 2glazing, or lave 2 glazing, dr lave 2 glazing, Grlav-e 0.400 0.400 0.400 w w w 11.20 11.20 11.20 25.22 522 18.70 18.70 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 . .__ A-_ 20azinq,drla-e--- 16A30ad_.� ---- 0.400 _ 0.032 _w _: - 11.20 _ _. 0.90 _... _15.16 224 0 .___. 164 ---0-__.0 _ 164.._.._- - 147 -_ -. 0 _ _.._ 367 ___-_ 0_____ _72 0 _.___. 72 ___. 0. .. __ 65 _.__ 0 _ _ _ 161 F 22A-tph 1.35B - 38.02 0.00 164 _ 18 684 0 72 8 304 0 6 c)AED excursion -68 -52 Envelope loss/gain 1696 853 924 555 12 a) Infiltration 2B6 76 127 34 b) Roan ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliancestother 500 500 Subtotal (lines 6 to 13) 1982 1430 1051 1089 Less endemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 5 13 0 0 14 Subtotal 1987 1442 1051 1089 15 Duct loads 25% 481/6 W6 696 25% 481/6 268 526 Total rows load 2493 2138 1319 1615 Air required (ofm) 99 95 52 72 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. wrY9titso• R- 2019Jul-Jul10:11:11 XREVEuhe®SIDENC .rup2D1Cale 8 RSt10Fro Pagel E:\Docunnets\Wrightsoft HVAC\REVELS RESIDENCE.rup CaIc=MJB Front Dow faces: N +wrightsoft° Right-M Worksheet Job: Entire House Date: Jul 05, 2019 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466.6799 I'm 772-466-6796 Email: OUICKCALCSQAOLCOM 1 2 3 4 5 Room name B�posed wall Room height Room dimensions Room area LIVING ROOM 14.0 It 11.0 it heat/cool 14.0 x 14.0 ft 196.0 fP M W C 23.0 it 9.3 It heat/cool 1.0 x 63.0 it 63.0 fP Ty Construction number U-value (Buthfi i°Fj Or HTM (Btuhfit� Area (ft� or perimeter (it) Load (Btuh) Area (fig or perimeter (0) Load (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 11 - 13A-4ocs 2glazing cir low-e 2 glazing, cir low-e 2 glazing cir low-e 2 glazing, cir lox e 1100_. -__ . __ 13A-4acs 2 glazing, cir lox-e 2 glazinq, cir lox-e_ 13A-40cs 2 gazing, cir lav-e 2 glazing, cir Iowa 2 glazing, cir low 2glmirg,.clr.low-e__. 13A-4ocs 2 glazing, cir law-e 2glazing, cir Im-e 2 glazing, cir low -a 2 glazing, cir low,e 16A30ad_ _- _ _ 22A-tph - 0143 -0400 0 400 0400 0.400 -.___0.390 0.143 0.400 _ _ 0.400 0.143 0.400 0.400 0.400 __-.0.400 0.143 0.400 0.400 0.400 _ _0.400 -_O,IXi2 -- 1.358 n n-- n in n _ n. a a ._e_ s s s s _s_ w w w w w_ = _ - -4011 1120 11 20 1120 11.20 __1092 4.00 11.20 11.20 4.00 11.20 11.20 11.20 _ _11.20 4.00 11.29 11.20 11.20 11.20 0.90 38.02 219 10.19 10.19 40A9 7.93 ----10.34 2.19 25.22 _25.22 2.19 10.19 10.19 10.19 -.._,.6.93 2.19 25.22 25.22 18.70 15.16 =2.24 0.00 0 - 0 0 0 0 _-.___0 0 0 _� 0 154 0 0 96 _.._-___.0 0 0 0 0 _____ .0 _. 796 196 .0 0. - 0 0 0 _._-.-0 0 0 __�_ 0 58 0 0 96 ___ __0 0 0 0 0 _�_ _ 0 __.- 196 14 _0 _0. 0 0 0 _.-_. 0 0 0 o __-0 _ 0 0 0 0 ___ _.,0 0 0 _r- 0 .-127 0 0 979 _.0 0 0 0 0 _ _ _ 0 --__439 0 '-0'-- 0 -0 0 0 _._.. _0 47 0 _ 0-- 121 0 0 0 _- -._._0 47 0 0 0 __ _ 0 _____ 63.-_. 63 0 0 - - 0 0 0 ,. . --0 47 0 0 121 b 0 0 ___-_. _0 47 0 0 0 __ _0 63 23 .___ _ 0 0 _ 0 0 0 0 166 0 _ 0 - 484 0 0 0 __ ..._._ 0 186 0 0 0 _ 0 _ ----56 875 ._ __ .0 0 - - -0 0 0 ----- __0 102 0 0 -_-- 265 0 0 0 ..__- --0 102 0 0 0 _ _ 0 �. _.141. 0 _..__ 1y II----GG _ _ _ - 232 0 0 1075 _ _-0 0 0 0 0 0 _-176 532 Vjf I--G F 6 c) AED excursion -22 32 Envelope lass/gain 2015 1523 1787 577 12 a) trffltration b) Room venilatim 244 0 65 0 339 0 91 0 13 btemai gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 2260 1588 2127 668 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 259/ 48/ 0 0 0 2260 57.9 0 0 0 1589 7% 251/6 48% 0 0 0 2127 541 0 0 0 669 322 Total rcom load Air.requir. (cfm) 2335 113 2355 105 2668 1. 991 44 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed ¢. -i .wWri9►�bo� 2019-Jul-0510:11:11 RightSuile® Universal 2019 19.0.08 RSU08101 Page 8 E:\Docunnets\Wrightsolt HVAC\REVELS RESIDENCEmp Calc=MJ8 From Door faces: N 1 1 wrightsoft Right-JO Worksheet Job: Date: Jul 05, 2019 Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-46G6799 Falc 772-466-6796 Emil: OUICKCALCS®AOLCOM 1 Room name MASTER BEDROOM M BATH 2 EKposed wall 23.0 It 23.0 It 3 Room height 10.3 ft heat/cod 9.3 ft heat/cool 4 5 Room dimensions Room area 13.0 x 18.0 It 234.0 ft2 1.0 x 164.0 it 164.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (BtuMti°F) (BtutVft2) a perimeter (ft) (Btuh) or perimeter (ft) (Bluh) Heat Cod Gross N/PIS Heat Cool Gross WPB Heat Cool 6 -13A-4acs _ 2 gluing, clr low-e --. 2 glazing, cir lav-e -0.143 0.400 0.400 --n - m n -- 4.00 11.20 11.20 2.19 10.19. 10.19 .0..0 _ 0 0 0 0 - , _ 0_ 0 0 -0 _ _0 0 84 _ 0 0- 72 0 0- 287 0 0- 157 0 0 2 glazing, clr low-e 0.400 n 11.20 10.19 0 0 0 0 0 0 0 0 11 2 glazing, cir low-e 0.400 n 11.20 7.93 0 0 0 0 12 0 134 95 11D0__.____ _ ,0.390 n_-__10.92 _. _10.34_ __.0 ._. _0 ___ 0 _.__.0___ 0_ ___0_. .0 --- --- 0 Vf/ F�-CC 13A-4ocs 2glazirg, clr lave 0.143 0.400 a a 4.00 11.20 219 25.22 52 0 52 0 206 0 113 0 47 0 47 0 186 0 102 0 _- VjI 2olazino. drlow-e _. 13A-4ocs 0.400 0.143 e. s - 11.20 4.00 2522 2.19 _-_ 0.. 0 ..-__0 0- _ __0 0 0 0 _ _ 0 0 _0 0 0 0 . ___0 0 �---G 2glirg, clr lav-e 0.400 s 11.20 10.19 0 0 0 0 0 0 0 0 GG 2 gluing, clr low-e 2 glazing, cir low-e 0.400 0.400 s s 11.20 11.20 10.19 10.19 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 - l)F----G 2 glazing, .clr.lav-e_ _ __ _0.400 _s_..'_11.20 __ 6.93 __'_' 0 _--_.__0 '__ __0 _. _- -0__ _. -0 _ --0 .._ __ 0 - -.._'_ 0 W, 0.400 w 4.20 2.22 185 140 590 320 84 72 280 150 2g1mins 2 glazing, clr low-e 2 glazing, dr low-e 0.400 0.400 w w 11.20 11.20 25.22 6 36 0 0 0 400 0 908 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.400 w 11.20 18.70 18.70 0 0 0 0 12 0 134 224 2glazirq, cir lav_e 16A30ad-___-- _ 0.400 ._0.032 w_ _ 11.20 .0.90 15.16 _ 2.24 __- _ 0 _ - 234 0 234 0 _ .210 0 _ _524-- _ 0 -�164 _ 0 _-_- 164 _ 0 ._-- - 147.__ _ _ 0 , 367 __ C _ F _ _ 22A-tPh_ .... 1.358 - 38.02 0.00 234 23 875 0 164 .- _ 23 - ... _ 875 _ 0 6 c) AED excursion 283 45 Envelope loss/gain 2292 2154 2051 1147 12 a) Infiltration 376 101 339 91 b) Room ventilation 0 0 0 0 13 Internal gars: Occupants Q 230 0 0 0 0 Appliances/otter 600 0 Subtotal (lines 6 to 13) 2568 2855 2390 1238 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtda 2668 2855 2390 1238 15 Duct loads 25% 48°h 679 1377 25% 48% 608 597 Total roan load 3347 4232 27 1836 Air required (rim) 133 188 119 82 Calculations approved bvACCA to meet all requirements of Manual J Sth Ed. Right-S,��;r9r<+�o, K- 2019-Jul10:11:11 " \REVE SR Universal nup Cale=MJ89.0.08 Front Page E:\Docrmnets\WrigMso9 FNAC\REVELS RESIDENCErep Cac=MJB From Door faces: N wrightsofC Right-JO Worksheet Job: Entire House Date: Jul 05, 2019 QUICK CALCS, INC. By: 317 STLUCIE LADE, FORT PIERCE, FL34946 Phone: 772-466-6799 Fax 772466-6796 Email: OUICKCALCSOAOL.COM i 2 3 4 5 Room name Fposed wall Rmm height Room dimensions Rmm area M TOR -ET 10.0 it 9.3 ft heatf000l 4.0 x 6.0 it 24.0 tt° Ty construction number U-wlue (Btuhttti°F) Or HTM (BtUMt2) Area (ft2) or perimeter (ft) Load (Btuh) Area a perimeter Load Heat Cool Gross NIFIS I Heat Cool Gross N/PIS Heat Cool 6 11 13A-0acs 2glazing, .cir low.e 2 glazing cir lave 2 glazing cir lave 2 glazing cir low-e 11D0-_ ___._._.. 13A-4acs 2glazirg, cir low-e 2 clazim, clr lava__ 13A-flocs 2glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 2glazirg,.ciclav:e.T______0.400._s_._-11.20 2glaflocs 2glazirg, clrlov-e 2 glazing, cir low-e 2 glazing, cir low-e 2 giazira cir low-e_. 16AJOad 22A-tph. 0.143 O400. 0.400 0.400 0.400 _ __ 0.390 0.143 0.400 T 0.400 --0.143 0.400 0.400 0.400 0.400 0.400 0.400 0.400 _ . _0.400 0.032 1_358 n n__, n n n __n_ a a e_ s s s s w w w w __w,_ -_ - 4 00 1120 11.20 11.20 11.20 10.92 4.00 11.20 -11.20 4.00 11.20 11.20 11.20 4.20 11.20 11.20 11.20 1120 ._.__ 0.90 98.02 2.19 10.19 10.19 10.19 7.93 10.34 219 25.22 25.22 �- 219 10.19 10.19 10.19 .._.6.93 2.22 25.22 25.22 1818.7070 _15.16 2.24 0.00 � - -37 0 --0 0 0 ._ ___0 0 0 _O 0 0 0 0 ---0 -- - -37 0 - 0 0 0 _.-___0 0 0 --'-- 149 0 -- - 0 0 0 __-0 0 0 O - --- 81 0 - - 0 0 0 0 0 __ 0 0 0 0 0 .`.__0.__ 120 0 0 0 -_ _ 0 _ _54 0 - - - - - - - -- �G �G VI GGi "__0 0 0 0 0 -.---0 0 0 0 0 __-0 Il�-`--f C 56 0 0 0 ___ 0 ��24 24 56 0 0 0 _� 0 --24 10 220 0 0 0 .-_ 0 __` 22 960 L���GCGG . _ p-__ F 6 c) AED excursion -13 Envelope loss/gain 774 244 12 a) Infiltration b) Room ventilation 148 0 40 0 13 Ntemal gains: OccuoWs Q 230 Appliances/other 0 0 O Subtotal Qines 6 to 13) 922 283 14 15 Less extemal load Less trensfer Redistribution Subtotal Duct Inds 251 48% 0 0 0 922 235 0 0 0 283 137 To[al room load Air required (cfm) 1 1156 1 46 420 19 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed - R' 2019Jul-05 10:11:11 RlghtSuae@ Universal 201919.0.08 RSU08101 Page 10 EADocumnets\Wrightsoft HVAC\REVELS RESIDENCE.rup Cale =MJB From Door faces: N -i�- wrightsoft9 Duct System Summary Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466.6799 Fax 772-466-6796 Emil: OUICKCALCS@AOL.COM For: REVELS RESIDENCE, PACE 2000, INC. 0 MOCO LANE, FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1173 cfm Job: Date: Ju105, 2019 By: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1173 cfm 206 ft Name Design (Btuh) Htg (Cfm) Clg (cfm) Design FR Diann (in) H x W (in) Duct Mat[ Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH c 912 39 41 1.000 6.0 Ox0 VIFx 27.1 135.0 St3 BEDROOM c 2161 74 96 1.000 7.0 Ox0 VIFx 15.1 115.0 SO BEDROOM h 3618 144 90 1.000 7.0 OXO VIFx 27.7 135.0 SO DINING h 2493 99 95 1.000 7.0 DO VIFx 7.6 115.0 st2 FOYER c 1615 152 72 1.000 6.0 Ox0 VIFx 36.5 135.0 st4 KITCHEWNOOK c 2118 40 94 1.000 7.0 ox0 VIFx 15.6 115.0 st1 KITCHENINOOK-A c 2118 40 94 1.000 7.0 OXO VIFx 11.2 115.0 st1 LIVING ROOM h 2835 113 105 1.000 7.0 Ox0 VIFx 39.8 135.0 st4 M BATH h 2998 119 82 1.000 6.0 Ox 0 VIFx 33.0 135.0 st4 M TOILET h 1156 46 19 1.000 4.0 Ox0 VIFx 39.7 135.0 st4 Mwic h 2668 106 44 1.000 6.0 Ox0 VIFx 51.1 155.0 sty MASTER BEDROOM c 2116 66 94 1.000 7.0 Ox0 VIFx 51.1 155.0 St5 MASTER BEDROOM -A C 2116 66 94 1.000 7.0 OXO VIFx 34.9 135.0 st4 OFFICE h 3434 136 97 1.000 7.0 Ox0 VIFx 31.3 135.0 SO PANTRY c 79 1 4 1.000 4.0 Ox0 VIFx 11.3 115.0 st1 unLITY c 1181 32 53 1.000 6.0 Ox0 VIFx 6.7 115.0 st2 w_rightsoft- 2019Jul-05 10:11:13 Right -Suite® Universal 2019 19.0.08 RSUDS101 Page 1 ^rr^ EADocurmets\Wrightsofl HVAC\REVELS RESIDENCE.rup Cale=MJ8 Front Door faces:N Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st4 Peak AVF 569 509 1.000 862 11.0 0 x 0 VinlFlx st2 st5 Peak AVF 172 138 1.000 494 8.0 0 x 0 VinlFlx st4 st2 Peak AVF 699 657 1.000 890 120 0 x 0 VinIFIX st3 Peak AVF 318 228 1.000 721 9.0 0 x 0 VinlFlx st1 st1 Peak AVF 474 516 1.000 782 11.0 0 x 0 VinlFlx Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 1173 1173 0 0 0 0 Ox 0 VIFx C wrrightsoPb 2019Jub0510:11:13 •Ww•LL-+•—.-. RlghtSuReG Universal 2019 19.0.08 RSU08101 Page 2 � EADocurnets\Wrightsoft HVAC\REVELS RESIDENCE.rup Calc=MJ8 Front Door faces: N This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF.