Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT SCANNED Street: THE STERLING Permit Office: ST. LUCIE COUNTY oe' o T City, State, Zip: FT. PIER FL , Owner: �� �\Q Permit Number: Jurisdiction: b St. LUCIp Courg, n'. Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(1442.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft' b. Frame -Wood, Adjacent R=11.0 192.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft. 4. Number of Bedrooms 2 d. N/A R= ft. 10. Ceiling Types (1474.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1474.00 ftz 6. Conditioned floor area above grade (ft') 1474 b. N/A R= ft' Conditioned floor area below grade (W) 0 c. WA R= ft° 11. Ducts R ft' 7. Windows(141.3 sqft.) Description Area a. Sup: Attic, Rat: Attic, AH: Attic 6 275 a. U-Factor: Sgl, U=1.04 101.25 ft' SHGC SHGC=0.29 b. U-Factor: Sgl, U=1.11 40.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor. N/A ftz SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.284 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1473.5 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft' b. Conservation features b. N/A R= ft' None c. N/A R= ft. 15. Credits Patel Glass/Floor Area: 0.096 Total Proposed Modified Loads: 47.03 PASS Total Baseline Loads: 48.47 I 1 hereby certify that the plans and specifications covered by Review of the plans and S7 ql� this calculation are in compliance with the Florida Energy specifications covered by this O�gBE Code. calculation indicates compliance y rii, j with the Florida Energy Code. run.= : •. •';':= '°'° . °, �O� PREPA D Y: DATE: - Before construction is completed this building will be inspected forOWN y 1 hereby certify that this building, as designed, is in compliance Florida S P with the Florida Energy Code. CODE COD L9ANCE OD {yE CR OWNER E I BUIL�I�IG DATE: DATE: x - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 A" RP,L', ). PV 9/11/2019 11:111 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 PROJECT Title: WYNNE THE STERLING Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1474 Lot# Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE STERLING Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Qomment: -- CLIMATE V Design Location TMY Site Design Temp 97.5 % 2.5 % Int Design Temp Heating Winter Summer Degree Days Design Daily Temp Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1474 11792 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 329 2632 No 0 1 1 Yes Yes Yes 2 `AlIC 63 504 No 0 1 No Yes Yes 3 M. BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 329 ft' ____ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft' ___ 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft' _-__ 0 1 0 4SIab-On-Grade Edge Insulatio KITCHEN 1 ft 0 192 ft' --__ 0 1 0 5SIab-On-Grade Edge Insulatio BATH 5 ft 0 45 ft' -_-- 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft' ___ 0 1 0 7SIab-On-Grade Edge Insulatio ENTRY 7 ft 0 55 ft' ___ 0 1 0 9/11/2019 8:10 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8Slab-On-Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ___ 0 1 0 9Slab-On-Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 ___ 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area i Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1553 ft2 246 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1474 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 329 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 0 1 NE=>SW Exterior Concrete Block- Ext Ins@EDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 - 2 SW=>NE Exterior Concrete Black- Ext Ins6iEDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.4 0 3 NW=>SE Exterior Concrete Block- Ext Ins®EDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 4 SW=>NE Exterior Concrete Block- Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 _ 5 NE=>SW Exterior Concrete Block- Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 6 NE=>SW Exterior Concrete Black- Ext InfiffDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.4 0 7 SE=>NW Exterior Concrete Block- Ext InREDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 8 S=>N Exterior Concrete Block - Ext InREDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.4 0 9 SW=>NE Exterior Concrete Block- Ext InOEDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0 10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 _11 SW=>NE Exterior Concrete Block- Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 12 SW=>NE Exterior Concrete Block- Ext InsillAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 13 NE=>SW Exterior Concrete Block - Ext In96REAT/DINI 4.1 26 0 8 0 208.0 ft2 0 0 0.4 0 _14 NW=>SE Exterior Concrete Block- Ext In93REAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.4 0 _15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft2 0.23 0.4 0 9/11/2019 8:10 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FOFkM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. . / Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal — 4 NE=>SW 13 Metal 5 NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes 1.04 0.29 N 32.9 ft' 1 ft 0 in 1 ft 5 in 1.04 0.29 N 6.9 ft' 1 ft 0 in 1 ft 5 in 1.04 0.29 N 24.0 k' 6 k 0 in 1 ft 5 in 1.04 0.29 N 37.5 ft' 1 ft 0 in 1 ft 5 in 1.11 0.27 N 40.0 ft' 8 ft 0 in 1 ft 5 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft' 315 ft' 24ft 8111 11 INFILTRATION # Scope Method SLA CFM 50 ELA Egl-A ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1375.7 75.53 142.04 .1233 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cent # Company Name Collector System Made[ # Collector Model # Area Storage Volume FEF None None ft' 9/11/2019 8:10 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FOF M R405-2017 INPUT SUMMARY CHECKLIST REPORT DUCTS / -- Supply --- — Return -- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 275 ft2 Attic 65 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y I Ceiling Fans: (( [[ �� Heating EX� Jan (Xl Feb [[ �� (XI Mar rr j May Jun �j Jun E ]J rrE ]] rr[[ Nov [[ ]] [[X]]Dec Venting 1111 Jan I[ 11 Feb [[X1l Mar Apr [ May Jun lXl Jul lXJ Aug lX� Sep [X] Oct [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 1 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 -68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 BEDROOM Default(8 lbs/sq.ft. ft' It 0.3 WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 M. BATH Default(8 lbs/sq.ft. ft' ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft2 ft 0.3 ENTRY Default(8 lbs/sq.ft. ft, ft 0.3 LAUNDRY Default(B lbs/sg.ft. ft2 ft 0.3 GREAT/DINING 9/11/2019 8:10 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y U Owner: Jurisdiction: w x Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with I ceiling/soffit The insulation in an dropped9 /soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. I Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity I sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and skylights and framing shall be sealed. and doors Rim joists 1 Rim joists shall include the air barrier. ' I Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) I of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to . exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind nirino and wirina Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box o 1 The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots l HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed I When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. 1 Caulking or other adhesive sealants shall not be used to fill voids I between fire sorinkler cover plates and waliq or ceilinas a. In addition, inspection of log walls shall be in accordance with the provisions of KX-400. 9/11/2019 6:10 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX" = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1474 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.060 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.284 c) Area 7c. 141.3 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floortype, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.1 14. Heating system: Capacity 34.8 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.97 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF 0 Heat recovery unit HeatRec% g) Other 1061. 11.0 1082. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 1la. 30.0 b) Cross ventilation No 11 b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes `Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. ` C, Builder Signature: Date: Q `\���` l Address of New Home: THE STERLING\'Zs _ 5\Ct c\ci: q City/FL Zip: ��qZis � Ct S 9/11/2019 8:10:40 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 ' +wrightsoftProject Summary o ta, Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN.,FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Emil: OUICKCALCS@( AOL.COM Project• • For. THE STERLNNE ING, FT. PIERCE, FL SENT CANNED 10 k1tandiol- Lane BY S$. Lucie Notes: CDllnty Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TD 42 OF 70 OF 28 OF Heating Summary Structure 18188 Btuh Ducts 5654 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipmentload 23942 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heatingg Coolingg Area (ft2) 1474 14A Volume (ft3) 12227 12227 Airchangeslhour 0.45 0.23 EquivAVF(cfm) 92 47 Heating Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Model 25HBC536A*030 AHRI ref . 7914585 Efficiency Heating input Heating output Temperature rise Actual airflow, Air flow factor Static pressure Space thermostat Capacity balance point = 33 OF Backup: 8.5 HSPF 34600 Btuh @ 47°F ocfrn 1160 0.049 cfmBtuh 0.50 in H2O Summer Design Conditions Outside db Inside db Design TD Daily range Relative humidity Moisture difference 90 75 15 L 50 61 OF OF 'F gdlb Sensible Cooling Equipment Load Sizing Structure 17877 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data In Rate/swing multiplier 0.95 25093 Btuh Equipment sensible load Latent Cooling Equipment Load Sizing Structure 2958 Btuh Ducts 2319 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5277 Btuh Equipment Total Load (Sen+Lat) 30370 Btuh Req. total capacity at 0.70 SHR 3.0 ton Cooling Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Cond 25HBC536AO30 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER,15 SEER Sensible cooling 24360 Btuh Latentcooling 10440 Btuh Total oling 34800 Btuh Adu AA v= COPY 1160 Airfl f�6100— 6 0.044 cfrn cfmBtuh Static pressure 0.50 in H2O Loadse*E%WWED FOR 0.83 CODE C®MPLIANCE Input=7kW, Output= 23009 Btuh, 100 AFUE ST. LUCIE COUNTY Calculations approved byACCA to meet all requirements ofgapWh Ed. -Fk- wr➢ghffio£Y' 2019-Aug-1509:26:43 RIgIt-Sdte®Urivemal 201919.0.07 RSU08101 Page 1 ...oa riskWrights°RHVAC\WYNNE-THESTERLING.rW Cale=MJ8 Frod Doorfaces: N WrightsoW Right-J®Worksheet Job: Entire House Date: ey: QUICK CALCS, INC. 317 ST. LUCIE UN.. FT. PIERCE, FL 34946 Prone:772-466-6799 Fax: 772-46C6796 Email: OUICKCALCS@AOL.COM 1 2 3 4 5 Room name Eryosedwell Room height Roam dimensions Room area Entire House 1582 It 8.3 It d 1473.5 ft329.0 BEDROOM 52.0 It 8.0 It heatt(=l 1.0 x 329.0 It ft Ty Construction number U-value (BWhtlx F) Or HTM (Bfuhlt') Area (fly or perimeter (f0 Load (Btuh) Area (fly or perimeter (ft) Load (BWh) Heal Cool Gross N/P/S Heat Cool Gross NrP/S Heat Cool ' 6 11 hr t 13A4locs 1Actom 0.149 _1270 0.143 1270 0290 _ =0.143 0.143 1270 ne _ne_ se se se — _s_ srr srr 4.00 �35.56 4.00 35.56 10.92 =.__ 4.00 4.00 35.56 — 2.55 _70.43 255 34.77 11.31 __. _255 255 42.91 479 �_38 128 24 22 _ - __60 360 7 442 0 1768 �1344 331 848 236 1124 ,2662 210 829 244 80 0 80 0 320 __0 0 0 0_ 204 0 0 0 0 WI — t—ta I—D 13A-4a 1Aclonl 11DO 13A-4ocs - 13A-4acs 1A tom 83 24 22 0 0 0 0 0 0 w W L—G =�3-4 353 5 1414 414 247 e6 899 298 0 224 0 0 224 0 0 887 0 0 570 0 W�--G 13A-4 s 1Aclom _A5stom 12C-Ow 0.143 1270 o.77d 0.091 7N nw _nw: - 4.00 35.66 �21.66 255 =090, 27.69 2.55 4524 _27.54 1.28 _232 0.00 290 33 a1 21.7 0 0 867 1162 _880 489 1320 434 551 1478 1124 246 3_419 0 112 33 a 79 0 0 318 1162 0 202 1478 0 D L—G 0 0 P 192 1474 1474 192 1414 156 0 329 329 329 52 _295 1440 763 0 C F t6A30md 22A-1DI 0.032 0.989 6 c)AEE excvrson 784 680 Envelope loss/gain 15366 13954 1 4432 3897 12 a) Infiltration b) Roomaentilation 2822 0 773 0 909 0 249 0 13 Intemalgains Oawpants@ 230 Aoplianoesrolher 5 1150 2000 2 460 0 Subtotal (1ines6 to 13) 18188 17877 5341 4606 14 15 Lessexlerrlal load Lesstransfer Redistribution Subtotal Duct oads 31% 48% 18188 5654 0 0 0 17877 8536 0 0 0 31-Aa 48% 0 0 0 5341 1660 0 0 0 4606 2199 Total room load AirrecI ired(dim) 23842 11. 26413 1160 7001 U1 6805 299 �� RigitSuleOUriv ml201919.0.07RSU08101 ..na iis%WrigitwftHVAC1WYNNE-TiESTERLINGnp Ca1c=MJ8 Frorl Doorfaces:N 2019-Aug-150926:43 Page 1 wrightsoft' Right-J®Worksheet Job: Entire House Date. QUICK CALCS, INC. By,. 317 ST. LUCIE LN.,Fr. PIERCE, FL 34946 PMre: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCSQAOL.COM 1 2 3 4 5 Room name Exposedwall Room height Room dimensions Room area WIC 0 it 8.0 It heaVmol 7.0 x 9.0 ft 63.0 ft' M BATH 8.0 ft 8.0 It heaV=l 7.0 x 8.0 ft 56.0 ft' Ty Construction number U-value (BWh4FVF) Or HTM (Btuhft' Area (v) or perimeter (ft) Load (Btuh) Area (q or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool • 6 -: 11 t -Ca f3-A 1Aclor0, 13AAors 1Aclom 11DO 0.143 1270 0.143 1270 0.390 -Fe- _ne_ se w se 4.00 _35.56 4.00 35.56 10.92 2.55 ^70.43 2.55 34.77 11.31 0 0 .. 0. 0 0 0 0-0-0 0 0 0 - 0 _,0 0 0 0 0 0 I W _ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W_ W L-G 13K- 13A-4ors 1Aclom _01_43 0.143 1270 _s_ sx sw 4.00 4.00 35.56 ._2.55 2.55 42.91 0 0 0 0=- 0 0 1 0 0 0 0 0 0 64 7 57 5 228 247 145 298 13A-00cs 1Ai1om AA5.2om 12C-Ow 16A_30mq 22A-fpl 0.143 1270 _0,770 0.091 my nw _rnv- - 4.00 35.56 _21.56 _2.55 0,90 27.69 2.55 4524 _27.54 128 2.32 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 P C� F 0 0 0 00 0 0 0 _O.11_32 0.989 _ _6.3 63 63 0 _56 0 146 0 -56 56 -5¢ 8 �50 222 _130 0 6 c)AEDexo>rJon -2 225 Envelope loss/gam 56 145 747 798 12 a) Infiltration b) Room ventilation 0 0 0 0 140 0 38 0 13 Internal gains Oampanls@ 230 ApplianoJother 0 0 0 0 0 0 Subtofal(lines 6 to 13) 56 145 887 836 14 15 Lesse#emalload Lesstransfer Redistribution Subtotal Ductloads 31% 48% 0 0 0 56 18 0 0 0 145 69 31% 48% 0 0 0 887 276 0 0 0 S36 399 Total room load Airrequired(Cm) 74 a 214 9 1162 57 1235 54 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 2019-Aug-150926:43 RigFFSuteOUriversa1201919.0.07RSU08101 a Paget ...oamerts\Wrigtisoft HUAC\WYNNE-THESTERLINGxW CaIc=MJ8 Frort Doorfaces: N 2 -�+wrightsoft' Right-M Worksheet Job: Entire House Date: sr• QUICK CALLS, INC. 317 ST. LUCIE LN., Fr. PIERCE, FL34946 PhDm:772-466-6799FU772-466-6796 Emil: OUICKCALCS@AOL.COM 1 2 3 4 5 Room name EIPosedwall Room height Roomdimensions Room area KrFCHEN 0 It 8.0 ft heaV000l 1.0 x 192.0 It 192.0 ft2 BATH 5.0 It 8.0 a heall000l 9.0 x 5.0 It 45.0 1? Ty Consb»mon number U-value (BtuhNN-°F) Or HTM (B1uhAt Area (M or perimeter (ft) Load (Btuh) Area (In a perimeter (ft) Load (Bluh) Heat I Cool Gross Nfpr. Heat Cool Gross NA'/S Heat Cool ' 6 11 ty'�� LG. 13A4oSs 1A Iom 19A4o s 1A-clam 1100 0.143 __1270 0.143 1270 0.390 rig _ne_ se se se 4.00 _35.56. 4.00 35.56 10.92 255 70.43 2.55 34.77 11.31 — -0 0 0 0 0 0 -0 0 40 0 40 0 0 0 0 160 0 0 0 0 102 0 0 0 0 IW _ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W_ N! I—r IV-4 s 13A4ocs 1A-oiom �0.7_43 0.143 1270 _s_ sv av =400 4.00 35.56 ,=255 2.55 42.91 '0 0 �_0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 G 13A4o s 1Aclom 4A -2om 12C-0sw 16A30md 22,5-h�l 0.143 1270 _0.770 0.091 _0.032 0.989 nw nw _rrv{ - = - 4.00 35.56 ,_21.56. _2.55 _0.90 27.69 2.55 4524 _2754 128 0 0 '0 0 0 0 0 0 __0 163 _172 0 0 0 0 —0-0-0 0 0 0 0 0 0 0 0 0 0 P ,C' F 64 64 192 82 445 0 0 0 0 192 45 45 40 104 0 _2.32 0.00 192 0 45 5 138 6 o)AED exurson 47 -2 Emelopelosslgain 335 501 339 204 12 a) Infiltration b) Roomventilation 0 0 0 0 87 0 24 0 13 Intamalgains Ooarpants@ 230 ApplianoeJother 0 0 2000 0 0 0 Subtota1(1ines6to13) 335 2501 426 228 14 15 Lessexemalload �bar,� Redistribution Subtotal Ductloads 31% 48% 0 0 0 335 104 2501 1194 0 0 0 31A 48% 0 0 0 426 133 0 0 0 228 109 Total room load Airreciuired (dim) 439 21 3695 162 559 27 338 15 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrlat � - 2019-Aug-150926:43 Rigtt-SdteOUriversa1201919.0.07 RSU08101 Page 3 ...ocmerts\WrIgMoftHVAC\WYNNE-THE STERUNG.rp Calc=MJ8 FrontDoorfaces: N wrightsoft Right-J®Worksheet -Job: Entire House Date: QUICK CALCS, INC. ey: 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 PInre:772-466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM 1 2 3 4 5 Room name Elposedvall Room height Room dimensions Room area BEDROOM2 322 ft 8.0 ft heaV000l 1.0 x 203.5 ft 203.5 ft2 ENTRY 7.0 It 8.0 ft heaVmol 1.0 x 55.0 ft 55.0 T Ty Construction number U-value (Btuhflti-F) Or HTM (BWh?n Area or perimeter r (f0 d (Btuh) Area OF) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cod .6 11 WW,, L-G M4 �Ac11om 0.143 127.0 0.143 1270 0.390 ne _ne_ w w se 4.00 _35.56. 4.00 3556 10.92 2.55 70.. 3 2.55 34.77 11.31 128 0 128 0 513 0 326 0 -0 0 -0 0 0 0 0 0 67 0 244 W El1AcIom 13A-4 s 11DO 80 24 0 56 24 0 225 848 0 143 829 0 48 0 22 26 0 22 106 0 236 -W W LG 13A-4o1s 1AAIom 1_394 __=�-T �0.143 0.1-270 1270 -_s_ w 4.00 35.56 5.56 _2.55 2.91 42.55 �_ - 16 �16 0 =16 16 0 64 �64 0 0 0 0 0 20 0 41 _41 0 8 0 8 0 32 0 13A-0as 1AcMo_m 4A5.2om 12C-Ow 16A30md gLA-tot 0.143 1270 _0.770 0.091 a0.032 0.989 rnV M nw. _nw- J - 4.00 , 35.56 _21.56 255 =0.90. 27.69 2.55 4524 _27.54 1.28 _2.32 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 P ,C, F 0 0 0 _0 0 _0 72 72 =b5 7 183 49 92 J128 0 _204 204 _204 32 _182 891 _472 0 =755 55 194 6 c)AEC e rsion -24 -6 Fs\elope losstgain 2859 1873 Boo 545 12 a) Infiltration b) Roomeenfilafion 564 0 154 0 122 0 34 0 13 Internal gains 0-pants@ 230 Applianre9other 1 230 0 0 0 0 Subtotal(Imes6to13) 3422 2257 922 579 14 15 Less exlemal load Lesstransfer Redistribution Subtotal Dud loads 31% 480/c 0 0 0 3422 1064 0 0 0 2257 1078 31% 48% 0 0 0 922 287 0 0 0 579 276 Total room load Airrecldred(tfm) 4486 218 3335 146 1209 59 855 38 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -P}F wrighmoTe- 2019-Aug-1509:26:43 Right-SuteOUrimml 201919.0.07 RSUOS101 Page 4 ...oamerts\WdgNwft FNAC\WYNNE-THESTERLINGnp Calc=MJB FrortDoorfams: N wrightsoft' Right-M Worksheet Job: Entire House Date: sy: QUICK CALCS, INC. 317 ST. LUCIE LN.,FT. PIERCE, FL 34946 Ptone: 7724666799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Elposedvall Room height Room dimensions Room area LAUNDRY 6.0 It 8.0 ft heaVmol 7.0 x 6.0 It 420 ft' GREAT/DINING 46.0 it 8.9 R heaV=l 1.0 x 488.0 It 488.0 ft' Ty Construdon number U-value (BWh4t-F) Or HTM Area (R') or perimeter (ft) Load (Bluh) Area (RF) or perimeter (to Load (Btuh) Heat Cool Grass NrPIS Heat Cool Gross NIPS Heat Cool - 6 11 VVNN 139A JAclom 13A-4= 1Actom 11DO 13A-_j= 13A4orS tAclom 0.143 _1270 0.143 1270 0.390 _0.143 0.143 1270 ne _ne- se se se _s_ sw six 4.00 _35.56. 4.00 35.56 10.92 4.00 4.00 35.56 2.55 _70.43 2.55 34.77 11.31 —2.55 2-55 42.91 0 0 o - __0 0 0 0 0 0 0 0 0 231 38 0 0 0 0 ' 194 0 0 0 0 0 0 775 1344. 0 0 0 0 0 493 _2662 0 0 0 0 0 IW - I---u t—D 0 0 0 0 0 0 0 0 0 0 0 0 yV= N! L—G 48 0 48 0 192 0 122 0 0 0 W G 13q-0ots 1AtIom 4AS-2om 12C-0sv _ 16A30md 22A-hil 0.143 1270 _0.770 0_091 my nw _Dw_ - 4 .00 35.66. _21.58. 2.55 =6K 27.69 2 .55 4524 _2754 128 0 0 0 0 0 0 9 0 a 0 0 0 178 0 44 0 137 0 0 0 549 0 _880 0 349 0 1124 0 P ,C= F 56 56 143 72 0.032 0.989 - =2,32 0.00 42 42 42 38 497. 488 4 88 46 437 1274 t132 0 6 166 0 488 6 c)AED exardon 56 Envelope losygain 539 288 5259 5704 12 a) Infiltrafion b) Roomventlaton 105 0 29 0 895 0 246 0 13 Internal gains Omrpanls@ 230 AppliancesAother 0 0 2 0 460 0 Subtotal(lines6to 13) 644 317 6154 6409 14 15 Lesextemalload Lestransfer Redistribution Subtotal Dudloads 31% 48% 644 200 0 0 0 317 151 0 0 0 31% 48% 0 0 0 6154 1913 0 0 0 6409 3060 Total room load Air required (dm) 844 41 468 21 8067 1 393 9469 416 Calculations approved byACCA to meet all requirements of Manual J 8th Ed -rid- wrlgF+�tsof'C' 2019-AU9-1509:26.43 Righ-Suites Universal 201919.0.07 RSU08101 Page 5 ..na rts\WdgttsoftHVAC\WYNNE-THESTERLING.nq Calc=MJ6 FrontDoorfaces: N + vvrightsoft Duct System Summary Date: Entire House By. QUICK CALCS, INC. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Phone:772-466-6799Fax772-466-6796 Email: QUICKCALCS@AOL.COM For. WYNNE DEVELOPMENT THE STERLING, FT. PIERCE, FL Extemal static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.284 in/100ft 1160 cfm iVt.] Supply Branch Detail Table Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0,284 in/100ft 1160 cfm Name Design (Btuh) Htg (cfin) Clg (cfm) Design FR Diam (in) HxW (in) Duct MEG Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 559 27 15 0.376 4.0 Ox0 VIFx 18.1 115.0 Ed BEDR00102 h 4486 218 146 0.374 6.0 Ox0 VIFx 18.6 115.0 st1 BEDROOWA h 3501 170 149 0.297 6.0 Ox 0 VIFx 33.1 135.0 st2 BEDROOM-B h 3501 170 149 0.284 6.0 Ox0 VIFx 41.1 135.0 st2 ENTRY h 1209 59 38 0.510 4.0 Ox0 VIFx 3.0 95.0 GREATDINING c 4735 196 208 0.318 7.0 0x0 VIFx 22.4 135.0 st2 GREATDINING-B c 4735 196 208 0.307 7.0 Ox0 VIFx 28.1 135.0 st2 KITCHEN c 3695 21 162 0.375 7.0 Ox0 VIFx 18.3 115.0 st1 LAUNDRY h 844 41 21 0.366 6.0 Ox0 VIFx 21.6 115.0 st1 M.BATH h 1162 57 54 0.366 4.0 Ox0 VIFx 21.6 115.0 st1 WIC c 214 4 9 0.310 4.0 0x0 VIFx 26.3 135.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (ctm) (ctm) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 737 724 0.284 689 14.0 0 x 0 VinlFlx SO Ed PeakAVF 1101 1122 0.284 804 16.0 0 x 0 VinlFlx wrightsof - 2019-Aug-150926:44 RigFFvSuite®Uriml201919.0.07RSU08101 Paget ...oa rls\Wrigtsoft WAMYNNE-THE STERLINGnp Calc=Mill Frort Door facesN Y Return Branch Detail Table Name Grille Size (in) Htg (dn Clg (Cfm TEL (ft) Design FR Veloc (fpm) Diam (in) HxW (in) Stud/Joist Opening (in) Duct Mat Trunk rb1 Ox 0 1160 1160 0 0 0 0 Ox 0 VIFx . w.rightsoR• Righ Sixte®Uriversa1201919.0.07 RSuo8101 t A ...00 its\WrigttsoftWAC\WYNNE-THESTERLING.Op Calc=W8 FrortDoorraces: N 2019-AtU-15 09:26:44 Page2