Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT SCANNED Street: t2coP-ra2-LAN'5 Permit Office: ST. LUCIE COUNTY BY City, State, Zip: FT. PIERCE, FL, Owner: WYNNE BUILDING COPR Permit Number. Jurisdiction: ST. LUCIE COUNTY / St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sgfL) Insulation Area _2._ Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst rase? Yes 10. Ceiling Types (1474.0 sgft.) Insulation Area • a. Under Attic (Vented) R=30.0 1474.00 ft2 6. Conditioned floor area above grade (ft2) 1474 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. R= z 11. Ducts R ft2 7. Windovis(141.3 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 250 a. U-Factor: Sgl, U=1.04 101.25 ft2 SHGC: SHGC=0.29 b. U-Factor. Sgl, U=1.11 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor. N/A 112 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.284 14. Hot water systems _ 8. Floor Types (1473.5 sgft.) Insulation Area a. Electric _ Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft2 b. Conservation features EF: 0.970 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 47.08 PASS Total Baseline Loads: 48.47 I hereby certify that the plans and specifications covered by Review of the plans and HE STq?� this calculation are in compliance with the Florida Energy specifications covered by this y = c O� Code. calculation indicates compliance with the Florida Energy Code. rnu'2." 2; °;;• ;, �O PREPA D BY' Before construction is completed v DATE: - this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. y� with the Florida Energy Code. �'Op WE {Rv OWNER/AGENT: BUILDING OFFICIAL: DATE: 8 iu -irt DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. FF11 - Compliance requires an Air Barrier and Insulation Inspection Checklist in accq g P_0.T11m11Wkhis project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50% tldrrpulkmCE CODUE. � 1 S10 LUCIE COUNTY FILE C 8115/2019 9:13 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE STERLING Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1474 Lot # Owner Name: WYNNE BUILDING COPR Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 90 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE _ / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range ' FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1474 11792 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 329 2632 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes _ 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 It 0 329 ft- ___ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft- ____ 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft' ___ 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 W ___ 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft' ___ 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft- ___ 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft- ___ 0 1 0 8/15/2019 9:13 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY Eft 0 42 ft' ____ 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft' _-_ 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1553 ft' 246 ft' Light N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1474 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 329 ft' 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft' 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft' 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45ft' 0.1 Wood 6 Under Attic (Vented) BEDROOM 30 Blown 204 ft' 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft' 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft' 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft' 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N=>E Exterior Concrete Block - Ext InsMEDROOM 4.1 10 0 8 0 80.0 ft' 0 0 0.4 0 2 N=>E Exterior Concrete Block - Ext Ins®EDROOM 4.1 28 0 8 0 224.0 ft' 0 0 0.4 0 3 N=>E Exterior Concrete Block - Ext InsiDEDROOM 4.1 14 0 8 0 112.0 ft' 0 0 0.4 0 4 N=>E Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft' 0 0 0.4 0 5 N=>E Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.4 0 6 N=>E Exterior Concrete Block - Ext InfiffDROOM 2 4.1 16 0 8 0 128.0 ft' 0 0 0.4 0 7 N=>E Exterior Concrete Block - Ext InQEDROOM 2 4.1 10 0 8 0 80.0 ft' 0 0 0.4 0 8 N=>E Exterior Concrete Block - Ext InRIEDROOM 2 4.1 4 3 8 0 34.0 ft' 0 0 0.4 0 9 N=>E Exterior Concrete Block - Ext InfiffDROOM 2 4.1 2 0 8 0 16.0 ft' 0 0 0.4 0 10 E=>S Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft' 0 0 0.4 0 11 E=>S Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft' 0 0 0.4 0 12 N=>E Exterior Concrete Block - Ext InsdIAUNDRY 4.1 6 0 8 0 48.0 ft' 0 0 0.4 0 13 S=>W Exterior Concrete Block - Ext InsOREAT/DINI 4.1 26 0 8 0 208.0 ft' 0 0 0.4 0 14 W=>N Exterior Concrete Block - Ext Ins3REAT/DINI 4.1 20 0 8 0 160.0 ft' 0 0 0.4 0 15 E=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ftx 0.23 0.4 0 8/15/2019 9:13 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1- SE=>SW Insulated ENTRY None .39 3 1 6 8 20.6 ft2 WINDOWS Orientation shown is the entered orientation => chan ed to Worst Case. / V # Wall Omt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 __ 2 3 4 5 N=>E 3 Metal N=>E 4 Metal N=>E 7 Metal S=>W 13 Metal W=>N 14 Metal Low-E Single Low_E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes 1.04 0.29 N 32.9 ft2 1 It 0 in 1 ft4 in _ 1.04 0.29_ N 6.9 ft2_ _ 1_It 0 in 1 ft9-in 1.04 0.29 N 24.0 ft2 6 It 0 in 1 ft 4 in 1.04 0.29 N 37.5 ft2 1 It 0 in 1 ft 4 in 1.11 0.27 N 40.0 ft2 8 It 0 in 1 ft 4 in Drapes/blinds _.None. _ None None Drapes/blinds Exterior 5 None. None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft2 315 ft2 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1375.7 75.53 142.04 .1233 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 8/15/2019 9:13 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DUCTS Supply — -- Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 250 ft' Attic 45 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablre'Thermostat: Ceiling Fans: ,]Y Heat ng Jan Feb Mar € Jun rX� [ ] Jul f ] rl Aug r [X� Sep (] [[X]] L a OctNov Dee rr Venting [ 1 Jan [ ]Feb l J l J X Mar Apr May lXl Jun [)Jul I 1 Aug [ Sep lxJ [X] Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating {WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft' 0 ft 0.3 BEDROOM Default(8 lbs/sq.ft. ft' ft 0.3 WIC Default(8 Ibs/sq.ft. It, ft 0.3 M. BATH - Default(8 lbs/sq.ft. ft' ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft' ft 0.3 BATH Default(8 Ibs/sq.ft. ft' ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' ft 0.3 ENTRY Default(8 lbs/sq.ft. ft' ft 0.3 LAUNDRY Default(8 Ibs1s.ft. ft2 ft 0.3 GREAT/DINING 8/16/2019 9:13 AM EnergyGaugeS USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: WYNNE BUILDING COPR Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce c� COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealingmaterial. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The Insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth In unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind ninhin and worina. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. in aoamon, Inspection or log walls shall be In accordance with the provisions of IGG-400. 8/15/2019 9:13 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single_ -family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No, of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1474 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.060 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.284 14. Heating system: Capacity 34.8 c) Area 7c. 141.3 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 0 Heat recovery unit HeatRec0/o B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 1082. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit 0 Programmable thermostat -Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: -'''= Date: g/�o �9 Address of New Home: 12 URTt�7_ 00E City/FL Zip: FT. PIERCE. FL 8/15/2019 9:13:38 AM EnergyGaugeO USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Project Summary a -�- wrightsoftm Entire House Br• QUICK CALCS, INC. 317 ST. LUCIE LN.,FT.PIERCE. FL 34946 Ptnre:772-466-6799 Fax 772-466-6796 Emil: OU1CKCALCSQAOL.COM For. ENT THE STERLING, YNNE E FTnPIERCE, FL CANNE® BY Notes: 5t. Lucie County Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outsidedb 42 OF Outsidedb 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18188 Btuh Structure 17877 Btuh Ducts 5654 Btuh Ducts 8536 Btuh Central vent (0 dim) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping0 Btuh qu pment load 23842 Btuh Use manufacturer's data n Ratelswing multiplier 0.95 Infiltration Equipment sensible load 25093 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2958 Btuh Ducts 2319 Btuh Central vent (0 cfm) 0 Btuh Heating Coolingg (none) Area (ftz) 1474 1474 Equipment latent load 5277 Btuh Volume (1P) 12227 12227 Airchanges/hour 0.45 0.23 Equipment TotalLoad(Sen+Lat) 30370 Btuh Equiv AVF (cfim) 92 47 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Carder Make Carrier Trade CARRIERAIR CONDITIONING Trade CARRIERAIR CONDITIONING Model 25HBC536A'030 Cond 25HBC536A'030 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER,15 SEER Heating Input Sensible cooling 24360 Btuh Heating output 34600 Btuh@47°F Latentcooling 10440 Btuh Temperature rise 27 OF Total cooling 34800 Btuh Actual airflow 1160 cfm Actual airflow 1160 cfm Airflowfactor 0.049 cfnBtuh Air flow factor 0.044 cfmBtuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.83 Capacity balance point = 33 OF IBnput=p7kW, Output= 23009 Btuh, 100 AFUE, FOR �+p�REVIEWE�D Calculations approved byACCAtomeet all requirell3@11t$PAPaniG09P i�pd.L IANCE -rl&-wrlgAhtsof!' ` T. ILU'li I 12019-Au7-1509:26A3 • ^�—.d—+ RigFFSWeoUriWM1201919.0.07RSU08101 /�'aa/� Pa e1 ...oarrerts\Wri9tlsoft FNAC\WYNNE-THE STERLING.np CaIc=MJB FrortDcorfaces: N BOC V g I�t jelghtsoft Right-J® Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN.,FT. PIERCE, FL 34946 P1ore: 772-466-6799 Fa 772-466-6796 Email: OUICKCALCS@AOL.COM 1 2 3 4 5 Room name Exposedvall Room height Roomdimensons Roomarea EntireHouse 1562 ft 8.3 it d 1473.5 ft' BEDROOM 52.0 it 8.0 it heayolol 1.0 x 329.0 It 329.0 it' Ty ,Construction number U-value (Btuh4IMF) Or HTM (BtuhAn Area (fl or perimeter (IQ Load (Btuh) Area (ft') or perimeter (it) Load (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool -'6 11 �/✓ 1—G '13A4a -- '1 Glom 13A-4as 1A-dom 11DO - 0.143 1270 0.143 1270 0.390 tie _ne- se se se ' -400 _3556 4.00 35.56 10.92 '-2.55- 70.43 2.55 34.77 11.31 '— 479'�'r" 38 128 24 22 442` 0 -1768 1344 331 848 236 "' 1124 �2662 210 829 244 --`-- BO' 0 _ --80' 0 - --320 0 -"- 204 0 W D 83 24 22 0 0 0 0 0 0 0 0 0 0 0 0 WW-- W LG 1394q¢ 13A-4acs tActom _0, 443 0.143 1270 ,s_ w eH 4,00 4.00 35.56 _2,55 2.55 42.91 34 360 7 =34 353 5 =136 96 899 298 0 224 0 ==70 ==O ==O 1414 247 224 0 897 0 570 0 13A-0ocs 1Ac1am 46S20M 12C-Ow 0.143 1270 0.770 0.091 w nW _mk - 400 3556 _2156 2.55 255 45.24 —27.54 128 290 33 41 217 0 0 867 1162 869 489 551 1478 1124 246 112 33 0 0 '79 0 —0 318 1162 —0 202 1478 0 0 P 192 192 0 0 Cd, _1EA=30md _OA_32 =, 0.90 _ 2.32 0.00 j474 1474 _�1474 156 —1320 4325 3419 0 _329 329 , _329 52 _ 295_ 1440 763 0 F• ??A-lq1 -0.989 - 27.69 6 c)AED exanson 784 680 EmPJopeloss'gain 153M 13954 4432 3897 12 a) Infiltration b) Roam entilation i 2822 0 773 0 909 0 249 0 13 Intemalgains O=pants@ 230 Applianoesbther 5 1160 2000 2 460 0 Subtotal (lineseto 13) 18188 17877 5341 4606 14 15 LesseMemalload Lesstransfer Redistribution Subotal Dud loads 31% 48% 0 0 0 18188 5654 0 0 0 17877 8536 31% 48% 0 0 0 5341 1660 0 0 0 46W 2199 Total room load Air required (dm) 23642 1160 26413 1160 7001 341 6805 299 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -�}!- wrtigFrrCooTC' 2019-Aug-1509:26A3 Riglt-SdteOUriverml201919.0.07 RSU08101 Page 1 ...ou rtslWrigltsoftWAC1WYNNE-THESTERLING.np CaIc=MJ8 Frort Deorfaces: N virrightsofY Right-M Worksheet Job: Entire House Date: • B QUICK CALCS, INC. r• 317 ST. LUCIE LN.,FF.. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCSu@AOL.COM 1 2 3 4 5 Room name Exposedwall Room height Room dimensions Room area WIC 0 It 8.0 It heaV000l 7.0 x 9.0 It 63.0 ft56.0 M BATH 8.0 It 8.0 It heaVcool 7.0 x 8.0 It IF Ty Construction number U-\elue (BWNItz°F) Or HTM (BfuhAt) Area (M or perimeter (M Load (BWh) Area (ft� or perimeter (it) Load (BWh) Heat Cool Gros N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 �G 13 744ocs .1Ac1om 13A-4ocs 1Ac1om 11DO 0.143 tie'..__ _ne_ se se se -4.00 _35.56 4.00 35.56 10.92 . 255 70.43 255 34.77 11.31 , - - 0 0 0 0 0 __ -0 0 - _ "0 '-0 - D' 0 ` 0 0 ._._ _ .0 0 __ 0 0 _. .0 0 W E2 _4270 0.143 1270 0.390 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 lN_ W LG _139A-= 13A-4ocs 1Ac1om _0.143 0.143 1270 _s _ sv sv 4 . 00 4.00 35.56 _255 255 42.91 0 0 0 0 0 0 0 0 0 64 7 0 57 5 0 228 247 0 145 298 0 0 0 0 13A-400s 1Aclom '4AS:2om 12C-Ow 0.143 1270 _0.770 0.091 T _ _0._032 0.989 my my _nw, = 4.00 35.56 _21.56 2.55 _0,90 27.69 255 4524 -___27,54 128 _2b2 0.00 0 0 0 0 '0 0 - 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _- P C_ F. 0 0 0 -0 0 -0 0 0 0 0 16A3pmd gMll 63 63 63 _56 0 146 0 56 56 =56 8 ^50 222 _130 0 0 6 c)AEC e rsion -2 225 Emelopelossrgain 56 145 747 798 12 a) Infiltration b) Roomeentilation 1 0 0 0 0 140 0 38 0 13 Intemal gains Ocoapants@ 230 Applianoes/olher 0 0 0 0 0 0 Subtot3l(1ines610 13) 56 145 887 836 14 15 Lessebemalload Lesiransfer Redistribution Subtotal Dudloads 31% 48% 0 0 0 56 18 0 0 0 145 69 31% 43 0 0 0 887 276 0 0 0 836 399 Total mom load Air required(cli 74 4 214 9 1162 57 1235 54 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -41- wrt`gl2, cw!- 2019-Aug-1 5 09:26A3 A�kRigid-SuteOUriversal 201919.0.07 RSU08101 Page 2 ... uatnerts\Wagttsoft HVAC\WYNNE-THESTERLING.np Calc=MIB FrortDoerfaws:N I vvrightsoft' Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN.,FT. PIERCE, FL 34946 Phone: 772466-6799 Fax772466-6796 Emit: OUICKCALCS@AOL.COM 1 2 3 4 5 Room name E77xsedwall Room height Room dimensions Room area KITCHEN 0 It 8.0 it heat/ocol 1.0 x 1920 it 1920 ft' BATH 5.0 it 8.0 it heal1=1 9.0 x 5.0 It 45.0 IF Ty Construcion number U-121ue (Btu!Wt F) Or HTM (Bhjw Area In or perimeter (ft) Load (BWh) Area In or perimeter (it) Load (Bluh) Heat TCool Gross N/P/S Heat Cool Gros N/P/S Heat Cool 6 11 ,1RJ LG. ,13A-0s- a -- - - - JAOom 0:143 1270 0.143 1270 0.390 -ne _ne- se se se -4.00 _35,56 4.00 35,56 10.92 — - 2.55� _70.43 255 34.77 11.31 —:� -0 -0 -- -0 0 -- -- --0 0 -- '0 0 - - � �40 0 40 0 0 0 0 - -160 0 0 V--G �D 13A-4ocs 1A-clom 11DO 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ,W W L_G _ W45 13A-00s IA-olom f01.43 0.143 1270 _s_ sw sv .—:.00 4.00 351% =255 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2.55 42.91 0 0 0 0 0 0 13A-0o� 1Ai1om AA5:2cm 12C-0sw _16A4Omd 22A-teal 0.143 1270 _0.7.70 0.091 0,032 0.989 n'w nw _nw. = 4.00 35M —21:56. 2.55 =0.90 27.69 255 4524 27.54 128 _2.32 0.00 0 0 0 0 0 0 0 0 b 0 0 o 0 0 0 -0-0 0 0 0 0, 0 0 0 . P C F. 64 192 192 64 163 82 0 0 0 0 _102 0 L2 0 445 45 45 40 _704 0 0 45 5 138 8 c)AEDe rsion -27 -2 Em,elopelossIgain 335 501 339 204 12 a) Infiltration b) Room %enfilatfon 0 0 0 0 87 0 24 0 13 Internal gains: O=pants(@ 230 Appliancesrother 0 0 2000 0 0 0 Subbtal(lines6lo13) 335 2501 426 228 14 15 Lesedemalload Lestransfer Redistribution Subtotal Duct loada 31% 48% 0 0 0 335 104 0 0 0 2501 1194 31% 480/. 0 0 0 426 133 0 0 0 228 109 Total room load Air required (clm) 439 21 3695 162 559 27 336 15 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrlghiooTe- 2019-Aug-1509:26:43 Rigrt--Sute®Uriwrsa1201919.0.07 RSU08101 Page 3 ...oa rts%WdgHsoft HVAC\WYNNE-7HESTERLING.Op Calc=MI6 FrortDoor Faces: N F wrightsoft' Right-M Worksheet Job: Entire House Date: . By., QUICK CALCS, INC. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Phne:772-466-6799 Fax 772-466-6796 Emil: OUICKCALCS@AOL.COM 1 2 3 4 5 Room name EVC9edwail Room height Room dimensions Roomarea BEDROOM2 322 ft 8.0 It heaV000l 1.0 x 203.5 It 203.5 IF ENTRY 7.0 It 8.0 ft heaV000l 1.0 x 55.0 ft 55.0 fO Ty Conshdon number U-value (BWhftk-q Or HTM (BluhMt� Area (f?) or perimeter (f) Load (Btuh) Area In or perimeter (ft) Load (BWh) Heat I Cool Gros N/P/S Heat I Cool Gross NIP/S Heat Ccol 6 11 �l?/ LG -13A-4 c _ - - - JACiom 13.4-0as 1A-donl 11DO 13A-4 s 13A-0as 1Aelom ---0.143 1270 �0.143 1270 0.390 _0.143 0.143 1270 rle'- _ne- se se se _s_ av sw -4.00 _35.56 4.00 35.56 10.92 4.00 4.00 3556 - 2.55 ,70.43 255 34.77 11.31 _2.55 255 42.91 - 128 0 --- 128 0 -513 0 225 848 0 - 326' 0 0 0 ' -0 0 �- -0 0. 0 0 67 0 244 W Ej D 80 24 0 16 _16 0 56 24 0 18 16 0 143 829 0 48 0 22 26 0 22 106 0 236 W WI - �--G _,_,164 64 0 86 41 0 0 8 0 0 0. 0 20 0 3 0 32 0 W, 13A4ocs 1AC1om 9A5.20m 12C-Ow 6A30md 22A-IPI 1.270 1270 _0.77.0 0.09ri1 _0.032 0.989 w nw - _ - 35.56 5.56 _21.56. _2.55 0.00 27.69 52 5524 4524 „2754 1.28 2.32 0.00 0 0 0 0 0 0 0 0 0 9 0 0 0 0 0 0 0 0 6 0 0 0 0 0 0 92 =128 0 P C_ F 0 0 0 72 72 _55 7 183 49 _204 204 �20_4 32 _182 891 472 0 55 55 194 6 c)AEDexcurdon -24 -6 Emelopeloss(gain 2859 1873 800 545 12 a) Infilb-aon b) Room eentiation 564 0 154 01 122 0 34 0 13 Inlemal gains: oovpanis@ 230 Appliancesbher 1 230 0 0 0 0 SubtDWgines6 to 13) 3422 2257 922 579 14 15 Lesse#emalload Lessfiansfer Redidflbution Subtotal Duciloads 31o/a 480/6 0 0 0 3422 1064 0 2257 1078 0 0 31% 48%1 0 0 0 922 2871 0 0 0 579 276 Total mom load Airrequired(c1m) 4486 218 3335 146 1209 59 855 38 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. #r- wrffwra ocwk- 2019-Atg-1509:26A3 . A Rigtt-StiteOUriw=1201919.0.07RSU08101 Page4 ...oa its\Wrightson HVAC\WYNNE-THESTERL1NG.rtp Calc=MJB FrortDoorfaces:N wrightsofr Right-M) Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Phoe:772-466-6799 Fax 772-466-6796 Emil: OUICKCALCS@AOL.COM 1 2 3 4 5 Room name E)posedvall Room height Roomdimensions Room area LAUNDRY 6.0 ft 8.0 it heaVcool 7.0 x 6.0 It 42.0 IF GREATIDINING 46.0 It 8.9 it heatf=l 1.0 x 488.0 R 488.0 ft Ty Constudon number U-value (StuhAtVF) Or HTM (Bbill" Area (ft�) or perimeter (ft) Load (Btuh) Area or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S I Heat Cool 6 11 115�J1 ' -G 13A�Iors _ 1Ac1bm 13A-4ors 1ACIorn 11D0 _ 0.143 _1270 0.143 1270 0.390 ne-. _0e- W w ce 400 -3556 4.00 35.56 10.92 2.55 70,43 2.55 34.77 11.31 . _ _ _0 0 . _ .0 - 0 - _ 231 38 0 0 0 - -- 194 0 . -775 1344 0 0 0 . -493 _,2662 0 0 0 W 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _W W L-G 13A-0ocs 13A-0as 1Actom =0_443 0.143 1270 _S_ sN sv =4. 00 4.00 35.56 =2.55 2.55 42.91 0 0 48 0 0 192 0 0 122 0 0 0 0 0 0 0 0 0 0 0. 0 0 48 0 �'IaI'r- 13A-4= 1Aclom 85,2om 12C-06w -164 Omd 0.143 1270 _0.770 0.091 W nw _nvc - 4.00 35.56 _21.56 _ 255 _0,90 27.69 255 4524 `27.54 128 0 0 -0 56 0 0 0 0 0 0 0178 0 041 0 0 - 137 0 0 -549 0 _880 0 349 0 _1124 0 '�G P C F. 56 14-3 72 0 =0032 0.989 - =2.32 0.00 42 42 38 166 97 0 488 488 486 46 437 1274 1 332 0 42 6 s c)AEDe rsan 3 56 Enw[opeloss(gain 539 288 5259 5704 12 a) Irriltration b) Room ventilation 105 0 29 0 895 0 245 0 13 Internal gains OoorpanSQ 230 Appliances(other 0 0 0 2 460 0 Subtotal (lines 6 to 13). 644 317 6154 6409 14 15 Less external load Lowtransfer Redistribution Subtotal Dudloads 31% 48% 0 0 0 644 200 0 0 0 317 151 31% 48% 0 0 0 6154 1913 0 0 0 6409 3060 Total room load Air required(dm) 844 41 468 21 8067 393 9469 416 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. wrlgraC cv t- 2019-Aug-150926:43 Rigit-Sute4DUriversa1201919.0.07 RSU08101 Page 5 ...oa rtslWdgiton HVAC\WYNNE-THESTERLING.np Catc=MJB FrontDoorfaces:N -- wrightsoft° Duct System Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LN.,Fr.. PIERCE, FL 34946 Phore: 772-4666799 Fax 772-466-6796 Email: QUiCKCALCS@AOL.COM For. WYNNE DEVELOPMENT THE STERLING, FT. PIERCE, FL Extemal static pressure Pressurelosses Available static pressure Supply/return available pressure Lowest fiction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.284 in/100ft 1160 cfm 176 it Job: Date: sy: Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250/0.250 in H2O 0.284 in/100ft 1160 dim Name Design (Btuh) Htg (Cfm) Clg (cfm) Design FR Diam (in) HxW (in) Dud Mad Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 559 27 15 0.376 4.0 Ox0 VIFx 18.1 115.0 st1 BEDROOM2 h 4486 218 146 0.374 6.0 Ox0 VIFx 18.6 115.0 st1 BEDROOWA h 3501 170 149 0.297 6.0 Ox0 VIFx 33.1 135.0 st2 BEDROOK&B h 3501 170 149 0.284 6.0 Ox0 VIFx 41.1 135.0 st2 ENTRY h 1209 59 38 0.510 4.0 Ox0 VIFx 3.0 95.0 GREATIDINING c 4735 196 208 0.318 7.0 Ox0 VIFx 22A 135.0 st2 GREATIDINING-B c 4735 196 208 0.307 7.0 Ox 0 VIFx 28.1 135.0 st2 KrrCHEN c 3695 21 162 0.375 7.0 Ox0 VIFx 18.3 115.0 st1 LAUNDRY h 844 41 21 0.366 6.0 Ox0 VIFx 21.6 115.0 st1 M.BATH h 1162 57 54 0.366 4.0 Ox0 VIFx 21.6 115.0 st1 wlc c 214 4 9 0.310 4.0 Ox0 VIFx 26.3 135.0 s2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam HxW Duct Name Type (drn) (cfrn) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 737 724 0.284 689 14.0 0 x 0 VInIFIX st1 SO PeakAVF 1101 1122 0.284 804 16.0 0 x 0 VinIFIX wrllghtsoR" 2019-ALU-150926:44 RigitStRe®Uriwml201919A.07RSU08101 Pagel ...ocmerts\WrigFtsoft HVAC\WYNNE-THE STERLING.Op Calc=MI8 Frort Door faces: N Return Branch Detail Table Name Grille Size (in) Htg (cfin) Clg (cfm) TEL (tt) Design FR Veloc (fpm) Diam (in) HxW (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox 0 1160 1160 0 0 0 0 Ox 0 VIFx * Wrlghtsof" 2019-ALU-150926.44 ACCK —; �r—a. Right-SUte0UrrverwI201919.0.07 RSU08101 Paget ...00merts\Wrigttsofl HUAC1WYNNE-THE STERLINGnp Cato =MJ6 Fruit DoorPaoes N