HomeMy WebLinkAboutD O H PAPERWORKSTATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL
SYSTEM
CONSTRUCTION PERMIT FOR:
APPLICANT:
OSTDS•New
PROPERTY ADDRESS: TBD Edwards Rd Fort Pierce, FL 34981
PERMIT #:56-SF-1977382
APPLICATION #:AP1425355
DATE PAID:
FEE PAID:
RECEIPT #:
DOCUMENT #: PR1248870
SCANNED
LOT: 6&7 BLOCK: SUBDIVISION: Sunset Park
PROPERTY ID #: 2430-501-0012-O00-Z [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER]
[OR TAX ID NUMBER]
SYSTEM MUST HE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION
381.0065, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE
SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS,
WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE
PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT ,IN THIS PERMIT BEING MADE NULL. AND VOID.
ISSUANCEOF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL,
STATE, OR LOCAL PERMITTING REQUIRED' FOR DEVELOPMENT OF THIS PROPERTY.
SYSTEM DESIGN AND SPECIFICATIONS
T [ 1,050 ] GALLONS / GPD Septic new CAPACITY
A [ ] GALLONS / GPD NIA CAPACITY
N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS]
K [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS 81 ]DOSES PER 24 HRS #Pumps [
D [. 500 ] SQUARE FEET Drainfield new SYSTEM
R ( ] SQUARE FEET N/A SYSTEM
A TYPE SYSTEM: [ ] STANDARD [ ] FILLED [X] MOUND [ ]
I CONFIGURATION: [X] TRENCH [ ] BED [ ]
N
F LOCATION OF BENCHMARK: Site BM NiD, N side of Edwards Rd
I ELEVATION OF PROPOSED SYSTEM SITE
E BOTTOM OF DRAINFIELD TO HE
L
D FILL REQUIRED: (22.001
0
T
H
E
R
gpd.
[ 11,00 ] [INCHES FT ] [ABOVE BELOW BENCHMARK/REFERENCE POINT
[ 7.00 ][ INCHES FT ][ABOVE HELOYr BENCHMARK/REFERENCE POINT
sized for 4 bedrooms with a maximum occupancy of 8.persons (2 per bedroom), .for a total estimated flow of
SPECIFICATIONS
BY: . Brian J IngEE2
TITLE: Environmental Specialist
II
.APPROVED BY:
TITLE: Environmental Specialist II
St. Lucie CHD
erim J Ingsp'
DATE ISSUED:
08116/P019 /
EXPIRATION DATE:
02/16/2021
DH 4016, 08/09
(Obsoletes all previous
editions which may not be used)
Incorporated:
64E-6.003, FAC
Page 1 of 3
v 1.1.4 M1425355 SE1198066
NOTICE OF RIGHTS
A'party whose substantial interest is affected by this order may petition for an
administrative hearing pursuant to sections 120.569 and 120.57, Florida Statutes. Such
proceedings are governed by Rule 28-106, Florida Administrative Code. A petition for
administrative hearing must be in writing and must be received by the Agency Clerk for the
Department, within twenty-one (21) days from the receipt of this order. The address of the
Agency Clerk is 4052 Bald Cypress Way, BIN A-02, Tallahassee, Florida 32399. The Agency
Clerk's facsimile number is 850-4.13-8743.
Mediation is not available as an alternative remedy.
Your failure to submit a petition for hearing within 21 days from receipt of this order will
constitute a waiver of your right to an administrative hearing, and this order shall become a'final
order.
Should this order become a final order, a party who is adversely affected by it is entitled
to judicial review pursuant to Section 120.68, Florida Statutes. Review proceedings are
governed by the Florida Rules of Appellate Procedure. Such proceedings may be commenced
by filing. one copy of a Notice of Appeal with the Agency Clerk of the Department of Health and a
second copy, accompanied by the filing fees required by law, with the Court of Appeal in the
appropriate District Court. The notice must be filed within 30 days of rendition of the final order.
HEM
St. Lucie County Health Department
5150 NW Milner Dr Port Saint Lucie, FL 34983
PAYING ON: a:56-SF-1977382 BILLODC#:56-BID-4264017 CONSTRUCTION APPLICATIONq:AP1425355
RECEIVED FROM: Atlantic Land Designs of the TC AMOUNT PAID: $ 545.00
PAYMENT FORM: CHECK 25242 PAYMENT DATE: 07124/2019
MAIL TO: (TNT Builders)
FACILITY NAME:
PROPERTY LOCATION:
TBD Edwards Rd
Fart Pierce, FL 34981
Lot: 6&7 Block:
Property ID:. 2430-501-0012-000-2
EXPLANATION or DESCRIPTION:
QUANTITY
FEE
128 - OSTDS Construction System Inspection Research Fee
1
$
5.00
-1 - Surcharge (All)
1
$
45.00
-1 - OSTDS New Permit Surcharge
1
$
100.00
-1 - OSTDS Construction Application and Plan Review,New
1
$
100.00
123- OSTDS Construction Site Evaluation
1
$
115.00
126 - OSTDS Construction Permit (New or Mod, Amendment)
1
$
55.00
127 - OSTDS Construction System Inspection
1
$
75.00
133 - OSTDS Construction Reinspection
1
$
50.00
RECEIVED BY: WhighamJL AUDIT CONTROL NO. 56-PID-4021457
SE-
y'
@. STATE. OF FLORIDA PERMIT NO. SE-L �
r DEPARTMENT OF HEALTH DATE PAID:
O,NSITE SEWAGE TREATMENT AND DISPOSAL FEE PAID:
SYSTEM RECEIPT #:
APPLICATION FOR CONSTRUCTION PERMIT
APPLICATION FOR:
[\/] New System [ ) Existing System [ ] Holding Tank [ 1 Innovative
[ ] Repair [ ] Abandonment. [ ] Temporary [ ]
APPLICANT: TNTBuilders
AGENT: Atlantic Land Designs of the Tc, Inc. TELEPHONE: 772-3984290
MAILING ADDRESS: PO Box 1421 Jensen Beach, Florida 34958 Email - ALD5543@Gmail.com
TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS MUST BE CONSTRUCTED
BY 'A PERSON LICENSED PURSUANT TO 489.105 (3) (in) OR 489.552, FLORIDA STATUTES. IT IS THE
APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT WAS CREATED OR
PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROVISIONS.
PROPERTY INFORMATION
LOT: 6,& 7 BLOCK: SUBDIVISION: Sunset Park Subdivision PLATTED: 1925
PROPERTY ID #: 2430-501-0012-000-2 ZONING: RS-3 I/M OR EQUIVALENT: [ No ]
PROPERTY SIZE: 1.05. ACRES WATER SUPPLY: [ ] PRIVATE PU9LIC [,11<=2000GPD [ ]>2000GPD
IS SEWER AVAILABLE'. AS PER 381.0065, FS7 [ NO ] DISTANCE TO SEWER. N/A FT
PROPERTY ADDRESS: TDB Edwards Road
DIRECTIONS TO PROPERTY: See attached Map
BUILDING INFORMATION [✓] RESIDENTIAL [. ] COMMERCIAL
Unit Type of No. of ' Building Commercial/Institutional System Design
No Establishment Bedrooms Area Sqft Table Y, Chapter 64E-6, PAC
1 Residential_ (p3
2'
3
4
[ 1 Floor/Equipment Drains[ ] Other (Specify) -
r
SIGNATURE:,�-
DN 4015, 08/09 Obao tea previous editions which may not be used)
Incorporated 64E- .001, FAC Page 1 of 4
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND -DISPOSAL SYSTEM
SITE EVALUATION AND SYSTEM SPECIFICATION
APPLICANT: TNT Builders
CONTRACTOR / AGENT: Atlantic Land Designs ofthe TC
LOT: 6&7 BLOCK:
SUBDIVISION: Sunset Park ID#: 2430-501-0012-000-2
APPLICATION # AP1425355
PERMIT # 56-SF-1977382
DOCUMENT # SE1198066
TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE, OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE
REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS.
PROPERTY SIZE CONFORMS TO SITE PLAN: [X]YES [ ]NO NET USABLE AREA AVAILABLE: 1,05 ACRES
TOTAL ESTIMATED SEWAGE FLOW: 400 GALLONS PER DAY [ RESIDENCES -TAB LEI / OTHER -TABLE 2 ]
AUTHORIZED SEWAGE. FLOW: 2625.00 GALLONS PER,DAY [ 1500 GPD/ACRE OR 2500'GPD/ACRE ]
UNOBSTRUCTED AREA AVAILABLE: 1000.00 SQFT UNOBSTRUCTED AREA REQUIRED: 1000.00 SOFT
BENCHMARK/REFERENCE POINT LOCATION:
ELEVATION OF'PROPOSED SYSTEM SITE, 11.00 [ INCHES / FT ] I: ABOVE / BELOW ] BENCHMARK/REFERENCE POINT
THE MINIMUM.. SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES
SURFACE WATER: FT DITCHES/SWALES: '100 FT NORMALLY WET: [ ]YES [X]NO
WELLS: PUBLIC: FT LIMITED USE: FT PRIVATE: 100 FT NON -POTABLE: FT
BUILDING FOUNDATIONS: 5 FT PROPERTY LINES: 35 FT POTABLE WATER LINES: 25 FT
SITE SUBJECT TO FREQUENT FLOODING? [ ]YES [X]NO 10 YEAR FLOODING?.[ ]YES [X]NOI
10 YEAR FLOOD ELEVATION FOR SITE: FT'[ MEL / NGVD ] SITE ELEVATION: FT [.MEL / NGVD
enrr. nnnsrr.R rucnavamrnN crmR RnTT. PROFILE INFORMATION SITE 2
USDA SOIL SERIES:Ankona, send
Munsell#/Color Texture
Depth
10YR 512 _.. - _
- Fine Sand
0 To 27 _
1 OYR 611
Fine Sand
20 To 27
tOYR 8/1
Fine Sand
27 To 33
10YR 712 ..
Fine Sand
33 To 37
1 OYR 513
Loamy. Fine Sand
37 To 43
10YR 612
Loamy Fine Sand
43 To 53
-10YR Oft - -
Fine Sand-
_53 To 59
10YR 5/3
Fine Sand
59 To 72
USDA SOIL SERIES:Ankona sand
Munsell #/Color Texture
Depth
10YR 5/2
Fine Sand
0 To 23
1 OYR 6/1
Fine Sand
22 To 27
I OYR 811
Fine Sand
27 To 33
1 OYR 7/2
Fine Sand
33 To 37
1 OYR 5/3
Loamy Fine Sand
37 To 44
1 OYR 6/3
Loamy Fine Sand
44 To 53
tOYR 612
Fine Sand
53 To 62
tOYR 512
Fine Sand
62 To 72
OBSERVED WATER TABLE: 61.00 INCHES [ ABOVE / EELOW ] EXISTING GRADE TYPE: [ 'PERCHED /. APPARENT ]
'ESTIMATED'WET SEASON WATER TABLE ELEVATION: 20 INCHES [.ABOVE / BELOW.] EXISTING GRADE
HIGH WATER TAELE VEGETATION: [ ]YES [X]NO MOTTLING: [X]YES [ ]NO DEPTH: 20.00 INCHES
SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: Fine Sand/0.80 DEPTH OF EXCAVATION: INCHES
DRAINFIELD CONFIGURATION: [X ] TRENCH [ ] HED [ ] OTHER (SPECIFY)
REMARKS/ADDITIONAL CRITERIA
WSWT determined using USDA WSS and soli borings.
1CY116)1 stripping In 10YR512 matrix >10% with diffuse boundaries starting at 20" In SBt.
SB7 11" below BM. SB210" below
DATE: 07/31/2019
SITE EVALUATED BY:
'Ingram, Brian (Tide: Enviro entarSpeciallst II) (ENVIRONMENTAL HEALTH)
IS 4015, 08/09 ;Obaolatae previous editions xhlch may be usad). Incorporated: 64E-6. 001, FAD Page 3 OP 4
AP1426355 EID1977382 v 1.0.2
0�n�e
STATE OF FLORIDA PERMIT #. 56'5r- 1117 732
DEPARTMENT OF HEALTH
Q ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
SITE EVALUATION AND SYSTEM SPECIFICATIONS
APPLICANT: TNT Builders AGENT: Almatic Land Designs of the TC, Inc.
LOT: 6 &'7 BLOCK:. SUBDIVISION: Sunset Park Subdivision
PROPERTY ID #: 2430-501-0012-000-2 [ Section/Township/Parcel No, or Tax ID Number ]
TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE,OR OTHER QUALIFIED PERSON. ENGINEERS
MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH.PAGE OF SUBMITTAL. COMPLETE ALL ITEMS.
PROPERTY SIZE CONFORMS TO SITE PLAN:
[✓] YES [ ]
NO NET USABLE AREA AVAILABLE: 1.05
ACRES
TOTAL ESTIMATED SEWAGE FLOW:
GALLONS
PER DAY [RESIDENCES-TABLET/OTHER-TABLE2
]
AUTHORIZED SEWAGE FLOW:
GALLONS
PER DAY [1500GPD/ACRE OR25000PD/ACRE
]
UNOBSTRUCTED AREA AVAILABLE:
SQFT
UNOBSTRUCTED AREA REQUIRED:
SQFT
BENCHMARK/REFERENCE POINT LOCATION:
ELEVATION OF PROPOSED SYSTEM SITE IS [INCHES/Fr ] [ABOVE/BELOW ] BENCHMARK/REFERENCE POINT
THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES
SURFACE WATER: 100 FT DITCHES/SWALES: 15 FT NORMALLY WET? [ I YES l✓] NO
WELLS: PUBLIC: 200 FT LIMITED USE: 100 FT PRIVATE: 75 FT NON —POTABLE: 50 FT
BUILDING FOUNDATIONS: 7 FT PROPERTY LINES: 11 FT POTABLE WATER LINES: 100 FT
'SITE SUBJECT TO FREQUENT FLOODING: [ ] YES [✓] NO 10 YEAR FLOODING? [ ] YES 1✓] NO
10 YEAR 'FLOOD ELEVATION FOR SITE: FT MSL/NGVD SITE ELEVATION: FT MSL/NGVD
1 VLY J118 1
MUNSELL #/COLOR TEXTURE
USDA SOIL SERIES:
030020414
TO
TO
TO
TO
10RF--3*"dl
USDA SOIL SERIES:
TEXTURE DEPTH
TO
TO
TO
TO
TO
OBSERVED WATER TABLE: INCHES [ABOVE/BELOW ') EXISTING GRADE. TYPE:[ PERCHED/ APPARENT ]
ESTIMATED WET SEASON WATER TABLE ELEVATION: INCHES [.ABOVE/BELOW ] EXISTING GRADE
HIGH WATER TABLE VEGETATION: [ ] YES [ ] NO MOTTLING: ( ] YES [ ] NO DEPTH: INCHES
SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: DEPTH OF EXCAVATION: INCHES
DRAINFIELD CONFIGURATION: [ ] TRENCH I I BED [ ] OTHER (SPECIFY)
REMARKS/ADDITIONAL CRITERIA:
SITE EVALUATED BY:
DH 4015, 08/09 (obsoletes previous editions which may not be used) Incoipofated: 64E-6.001, FAC Page 3 of 4
. .•-1„ r r{� !. .f � ' S is �.. _ice
'� 9"• a ;' ,}r • ._�' � , � ' � J,,
",y ail• —f 4 .3 r ' _ F� r'S 1 '�� I r.
48
Wit—
y 5,�
2 i t
'—1 E *' r' Edwards Rd
`61.1-B
t •, __ •!
• Lam. � i y iT— , �,��, `y».'�ti-�'i'Iy
S�I]T7»;p ��'J uu�G b� m�7adJ �ft Ldh9�a�lkb� ' i � ' • ! i _.—
Custom Soil Resource Report
St. Lucie County, Florida
2=Ankona and Farmton sands
Map. Unit Setting
National map unft symbol: 1)pty
Elevation: 20 to 200 feet
Mean annual precipitation: 49 to 58 inches
Mean annual airtemperature: 70 to 77 degrees F
Frost -free period. 350 to 365 days
Farmland classification: Not prime farmland
Map Unit Composition
Ankona and similar soils. 50 percent
Farmton and similar soils: 40 percent
Minor components. 10 percent
Estimates are based on observations, descriptions, and transacts of the mapunit.
Description of Ankona.
Setting
Landform: Flatwoods on marine terraces
Landform position{three-dimensional): Talf
Down -slope shape: Convex
Across -slope shape: Linear
Parent material., Sandy and loamy marine deposits
Typical profile
A - 0 to 11 inches:. sand
E - 11 to 38 inches: sand
Bh - 38 to 48 inches: loamy sand
Btg - 48 to 57 inches: sandy loam
Cg - 57 to 80 inches., loamy fine sand
Properties and qualities
Slope: 0 to 2 percent
Depth to restrictive feature: 31 to 50 inches to ortstein
Natural drainage class, Poorly drained'
Runoff class: High
Capacity of the most limiting layer to transmit water (Ksat): Moderately low to
moderately high (0.06 to 0.20 In/hr)
Depth to water table: About 6 to 18 inches
Frequency of flooding. None
Frequency of ponding. None
Salinity, maximum in profile: Nonsaline to very slightly saline (0.0 to 2.0
mmhos/cm)
Sodium adsorption ratio, maximum in profile: 4.0
Available water storage in profile: Very low (about 1.5 inches)
Interpretive groups
Land capability classification (irrigated): None specified,
Land capability classification (nonirrigated): 4w
Hydrologic Soil Group: CID
Forage suitability group: Sandy soils on flats ofinesic or hydric lowlands
(G156BC141FL)
10
Custom Soil Resource Report
Hydric soil rating. No
Description of Farmton
Setting
Landform: Flatwoods on marine terraces
Landform position (three-dimensional): Interfluve, talf
Down -slope shape: Convex
Across -slope shape: Linear
Parent material, Sandy and loamy marine deposits
Typical profile
A - 0 to 7 inches: sand
E - 7 to 34 inches: sand
Bh - 34 to 50 inches: sand
Btg - 50 to 80 inches: sandy loam
Properties and qualities
Slope: 0 to 2 percent
Depth to restrictive feature: More, than 80 inches
Natural drainage class: Poorly drained
Runoff class: High
Capacity of the most limiting layer to transmit water (Ksafl: Moderately low to
moderately high (0.06 to 0.20 inlhr)
Depth to water tab'le: About to 18 inches
Frequency of flooding: None
Frequency of ponding. None
Salinity, maximum in profile: Nonsaline to very slightly saline (0.0 to 2.0
mmhoslcm).
Sodium adsorption ratio, maximum in profile: 4.0
Available water storage in profile: Moderate (about 6.9 inches)
Interpretive groups
Land capability classification (irrigated): None specified
Land capability classification (nonirrigated): 4w
Hydrologic Soil Group: B/D
Forage suitability group: Sandy soils on flats of mesic or hydric lowlands
(G156BC141FL)
Hydric soil rating: No
Minor Components
Electra
Percent of map unit: 4 percent
Landform: Knolls on marine terraces, rises on marine terraces
Landform position (three-dimensional): Interfluve
Down -slope shape: Convex
Across -slope shape: Linear
Hydric soil rating. No
Waveland
Percent of map unit: 3 percent
Landform: Flatwoods on marine. terraces
Landform position (three-dimensional): Talf
Down -slope shape: Convex
Across -slope shape: Linear
Hydric soil rating. No
11
Custom Soil Resource Report
Lawnwood
Percent of map unit. 3 percent
Landform: Marine terraces on flatwoods
Landform position (three-dimensional): Talf
Down -slope shape: Linear
Across -slope shape: Linear
Hydric loll rating., No
48—Wabasso sand, 0 to 2 percent slopes
Map Unit Setting
National map unit symbol: 2svyr
Elevation: 0 to 70 feet
Mean annual precipitation: 46 to 55 inches
Mean annual airtemperature: 70 to 77 degrees F
Frost -free period., 355 to 365 days
Farmland, classification: Farmland of unique importance
Map Unit Composition
Wabasso and similar soils: 85 percent
Minor components: 15 percent
Estimates are based on observations, descriptions, and transacts of the mapunit.
Description of Wabasso
Setting
Landform: Flatwoods on marine terraces
Landform position (three-dimensional): Tread, talf
Down -slope shape: Linear
Across -slope shape: Linear
Parent material: Sandy and loamy marine deposits
Typical profile
A 0 to, 6 inches: sand
E - 6 to 25 inches. sand
Bh - 25 to 30 inches: sand,
Big - 30 to 58 inches: sandy clay loam
Cg - 58 to 80 inches: loamy sand
Properties and qualities
Slope: 0 to 2 percent
Depth to restrictive feature; 9 to 50 inches to strongly contrasting textural
stratification
Natural drainage class: Poorly drained
Runoff class. Very high
Capacity of the most limiting layer to transmit, water (Ksat): Moderately low to
moderately high (0.06 to 0.20 inthr)
Depth to water table: About 6 to 18 inches
Frequency of flooding. None
12
Custom Soil Resource Report
Frequency ofponding., None
Calcium carbonate, maximum in profile: 5 percent
Salinity, maximum in profile: Nonsaline to very slightly saline (0.0 to 2.0
mmhos/cm)
Sodium adsorption ratio, maximum in profile: 4.0
Available water storage In profile: Very low (about 1.4 inches)
Interpretive groups
Land capability classification (irrigated): None specified
Land capability classification (nonirrigated): 3w
Hydrologic Soil Group: C/D
Forage suitability group: Sandy soils on flats of mesic or hydric lowlands
(G155XB141FL)'
Other vegetative classification: South Florida Flatwoods (RI55XY003FL)
Hydric soil rating. No
Minor Components
Hallandale
Percent of map unit 6"percent
Landform: Flatwoods on marine terraces
Landform position (three-dimensional): Tread, tall
Down -slope shape: Linear
Across -slope shape: Linear
Other vegetative classification: South Florida Flatwoods, (R155XY003FL)
Hydric soil rating. Yes
Boca
Percent of map unit., 5 percent
Landform: Drainageways on marine terraces, flats on marine terraces
Landform position (three-dimensional): Tread, dip, talf
Down -slope shape:' Linear, convex
Across -slope shape: Linear, concave
Ecologicalsite: South Florida Flatwoods (R155XY003FL)
Other vegetative classification: South Florida Flatwoods (R155XY003FL)
Hydric soil rating: Yes
Pineda
Percent of map unit., 4 percent
Landform: Drainageways on marine terraces, flats on marine terraces
Landform position (three-dimensional): Tread, dip, tall
Down -slope shape: Linear
Across -slope shape: Concave, linear
Other vegetative classification: Slough (R1 55XY01 I FL)
Hydric soil rating. Yes -
13
J-
a