Loading...
HomeMy WebLinkAboutD O H PAPERWORKSTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION PERMIT FOR: APPLICANT: OSTDS•New PROPERTY ADDRESS: TBD Edwards Rd Fort Pierce, FL 34981 PERMIT #:56-SF-1977382 APPLICATION #:AP1425355 DATE PAID: FEE PAID: RECEIPT #: DOCUMENT #: PR1248870 SCANNED LOT: 6&7 BLOCK: SUBDIVISION: Sunset Park PROPERTY ID #: 2430-501-0012-O00-Z [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER] [OR TAX ID NUMBER] SYSTEM MUST HE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION 381.0065, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS, WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT ,IN THIS PERMIT BEING MADE NULL. AND VOID. ISSUANCEOF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, STATE, OR LOCAL PERMITTING REQUIRED' FOR DEVELOPMENT OF THIS PROPERTY. SYSTEM DESIGN AND SPECIFICATIONS T [ 1,050 ] GALLONS / GPD Septic new CAPACITY A [ ] GALLONS / GPD NIA CAPACITY N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS] K [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS 81 ]DOSES PER 24 HRS #Pumps [ D [. 500 ] SQUARE FEET Drainfield new SYSTEM R ( ] SQUARE FEET N/A SYSTEM A TYPE SYSTEM: [ ] STANDARD [ ] FILLED [X] MOUND [ ] I CONFIGURATION: [X] TRENCH [ ] BED [ ] N F LOCATION OF BENCHMARK: Site BM NiD, N side of Edwards Rd I ELEVATION OF PROPOSED SYSTEM SITE E BOTTOM OF DRAINFIELD TO HE L D FILL REQUIRED: (22.001 0 T H E R gpd. [ 11,00 ] [INCHES FT ] [ABOVE BELOW BENCHMARK/REFERENCE POINT [ 7.00 ][ INCHES FT ][ABOVE HELOYr BENCHMARK/REFERENCE POINT sized for 4 bedrooms with a maximum occupancy of 8.persons (2 per bedroom), .for a total estimated flow of SPECIFICATIONS BY: . Brian J IngEE2 TITLE: Environmental Specialist II .APPROVED BY: TITLE: Environmental Specialist II St. Lucie CHD erim J Ingsp' DATE ISSUED: 08116/P019 / EXPIRATION DATE: 02/16/2021 DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 1 of 3 v 1.1.4 M1425355 SE1198066 NOTICE OF RIGHTS A'party whose substantial interest is affected by this order may petition for an administrative hearing pursuant to sections 120.569 and 120.57, Florida Statutes. Such proceedings are governed by Rule 28-106, Florida Administrative Code. A petition for administrative hearing must be in writing and must be received by the Agency Clerk for the Department, within twenty-one (21) days from the receipt of this order. The address of the Agency Clerk is 4052 Bald Cypress Way, BIN A-02, Tallahassee, Florida 32399. The Agency Clerk's facsimile number is 850-4.13-8743. Mediation is not available as an alternative remedy. Your failure to submit a petition for hearing within 21 days from receipt of this order will constitute a waiver of your right to an administrative hearing, and this order shall become a'final order. Should this order become a final order, a party who is adversely affected by it is entitled to judicial review pursuant to Section 120.68, Florida Statutes. Review proceedings are governed by the Florida Rules of Appellate Procedure. Such proceedings may be commenced by filing. one copy of a Notice of Appeal with the Agency Clerk of the Department of Health and a second copy, accompanied by the filing fees required by law, with the Court of Appeal in the appropriate District Court. The notice must be filed within 30 days of rendition of the final order. HEM St. Lucie County Health Department 5150 NW Milner Dr Port Saint Lucie, FL 34983 PAYING ON: a:56-SF-1977382 BILLODC#:56-BID-4264017 CONSTRUCTION APPLICATIONq:AP1425355 RECEIVED FROM: Atlantic Land Designs of the TC AMOUNT PAID: $ 545.00 PAYMENT FORM: CHECK 25242 PAYMENT DATE: 07124/2019 MAIL TO: (TNT Builders) FACILITY NAME: PROPERTY LOCATION: TBD Edwards Rd Fart Pierce, FL 34981 Lot: 6&7 Block: Property ID:. 2430-501-0012-000-2 EXPLANATION or DESCRIPTION: QUANTITY FEE 128 - OSTDS Construction System Inspection Research Fee 1 $ 5.00 -1 - Surcharge (All) 1 $ 45.00 -1 - OSTDS New Permit Surcharge 1 $ 100.00 -1 - OSTDS Construction Application and Plan Review,New 1 $ 100.00 123- OSTDS Construction Site Evaluation 1 $ 115.00 126 - OSTDS Construction Permit (New or Mod, Amendment) 1 $ 55.00 127 - OSTDS Construction System Inspection 1 $ 75.00 133 - OSTDS Construction Reinspection 1 $ 50.00 RECEIVED BY: WhighamJL AUDIT CONTROL NO. 56-PID-4021457 SE- y' @. STATE. OF FLORIDA PERMIT NO. SE-L � r DEPARTMENT OF HEALTH DATE PAID: O,NSITE SEWAGE TREATMENT AND DISPOSAL FEE PAID: SYSTEM RECEIPT #: APPLICATION FOR CONSTRUCTION PERMIT APPLICATION FOR: [\/] New System [ ) Existing System [ ] Holding Tank [ 1 Innovative [ ] Repair [ ] Abandonment. [ ] Temporary [ ] APPLICANT: TNTBuilders AGENT: Atlantic Land Designs of the Tc, Inc. TELEPHONE: 772-3984290 MAILING ADDRESS: PO Box 1421 Jensen Beach, Florida 34958 Email - ALD5543@Gmail.com TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS MUST BE CONSTRUCTED BY 'A PERSON LICENSED PURSUANT TO 489.105 (3) (in) OR 489.552, FLORIDA STATUTES. IT IS THE APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT WAS CREATED OR PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROVISIONS. PROPERTY INFORMATION LOT: 6,& 7 BLOCK: SUBDIVISION: Sunset Park Subdivision PLATTED: 1925 PROPERTY ID #: 2430-501-0012-000-2 ZONING: RS-3 I/M OR EQUIVALENT: [ No ] PROPERTY SIZE: 1.05. ACRES WATER SUPPLY: [ ] PRIVATE PU9LIC [,11<=2000GPD [ ]>2000GPD IS SEWER AVAILABLE'. AS PER 381.0065, FS7 [ NO ] DISTANCE TO SEWER. N/A FT PROPERTY ADDRESS: TDB Edwards Road DIRECTIONS TO PROPERTY: See attached Map BUILDING INFORMATION [✓] RESIDENTIAL [. ] COMMERCIAL Unit Type of No. of ' Building Commercial/Institutional System Design No Establishment Bedrooms Area Sqft Table Y, Chapter 64E-6, PAC 1 Residential_ (p3 2' 3 4 [ 1 Floor/Equipment Drains[ ] Other (Specify) - r SIGNATURE:,�- DN 4015, 08/09 Obao tea previous editions which may not be used) Incorporated 64E- .001, FAC Page 1 of 4 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND -DISPOSAL SYSTEM SITE EVALUATION AND SYSTEM SPECIFICATION APPLICANT: TNT Builders CONTRACTOR / AGENT: Atlantic Land Designs ofthe TC LOT: 6&7 BLOCK: SUBDIVISION: Sunset Park ID#: 2430-501-0012-000-2 APPLICATION # AP1425355 PERMIT # 56-SF-1977382 DOCUMENT # SE1198066 TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE, OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS. PROPERTY SIZE CONFORMS TO SITE PLAN: [X]YES [ ]NO NET USABLE AREA AVAILABLE: 1,05 ACRES TOTAL ESTIMATED SEWAGE FLOW: 400 GALLONS PER DAY [ RESIDENCES -TAB LEI / OTHER -TABLE 2 ] AUTHORIZED SEWAGE. FLOW: 2625.00 GALLONS PER,DAY [ 1500 GPD/ACRE OR 2500'GPD/ACRE ] UNOBSTRUCTED AREA AVAILABLE: 1000.00 SQFT UNOBSTRUCTED AREA REQUIRED: 1000.00 SOFT BENCHMARK/REFERENCE POINT LOCATION: ELEVATION OF'PROPOSED SYSTEM SITE, 11.00 [ INCHES / FT ] I: ABOVE / BELOW ] BENCHMARK/REFERENCE POINT THE MINIMUM.. SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER: FT DITCHES/SWALES: '100 FT NORMALLY WET: [ ]YES [X]NO WELLS: PUBLIC: FT LIMITED USE: FT PRIVATE: 100 FT NON -POTABLE: FT BUILDING FOUNDATIONS: 5 FT PROPERTY LINES: 35 FT POTABLE WATER LINES: 25 FT SITE SUBJECT TO FREQUENT FLOODING? [ ]YES [X]NO 10 YEAR FLOODING?.[ ]YES [X]NOI 10 YEAR FLOOD ELEVATION FOR SITE: FT'[ MEL / NGVD ] SITE ELEVATION: FT [.MEL / NGVD enrr. nnnsrr.R rucnavamrnN crmR RnTT. PROFILE INFORMATION SITE 2 USDA SOIL SERIES:Ankona, send Munsell#/Color Texture Depth 10YR 512 _.. - _ - Fine Sand 0 To 27 _ 1 OYR 611 Fine Sand 20 To 27 tOYR 8/1 Fine Sand 27 To 33 10YR 712 .. Fine Sand 33 To 37 1 OYR 513 Loamy. Fine Sand 37 To 43 10YR 612 Loamy Fine Sand 43 To 53 -10YR Oft - - Fine Sand- _53 To 59 10YR 5/3 Fine Sand 59 To 72 USDA SOIL SERIES:Ankona sand Munsell #/Color Texture Depth 10YR 5/2 Fine Sand 0 To 23 1 OYR 6/1 Fine Sand 22 To 27 I OYR 811 Fine Sand 27 To 33 1 OYR 7/2 Fine Sand 33 To 37 1 OYR 5/3 Loamy Fine Sand 37 To 44 1 OYR 6/3 Loamy Fine Sand 44 To 53 tOYR 612 Fine Sand 53 To 62 tOYR 512 Fine Sand 62 To 72 OBSERVED WATER TABLE: 61.00 INCHES [ ABOVE / EELOW ] EXISTING GRADE TYPE: [ 'PERCHED /. APPARENT ] 'ESTIMATED'WET SEASON WATER TABLE ELEVATION: 20 INCHES [.ABOVE / BELOW.] EXISTING GRADE HIGH WATER TAELE VEGETATION: [ ]YES [X]NO MOTTLING: [X]YES [ ]NO DEPTH: 20.00 INCHES SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: Fine Sand/0.80 DEPTH OF EXCAVATION: INCHES DRAINFIELD CONFIGURATION: [X ] TRENCH [ ] HED [ ] OTHER (SPECIFY) REMARKS/ADDITIONAL CRITERIA WSWT determined using USDA WSS and soli borings. 1CY116)1 stripping In 10YR512 matrix >10% with diffuse boundaries starting at 20" In SBt. SB7 11" below BM. SB210" below DATE: 07/31/2019 SITE EVALUATED BY: 'Ingram, Brian (Tide: Enviro entarSpeciallst II) (ENVIRONMENTAL HEALTH) IS 4015, 08/09 ;Obaolatae previous editions xhlch may be usad). Incorporated: 64E-6. 001, FAD Page 3 OP 4 AP1426355 EID1977382 v 1.0.2 0�n�e STATE OF FLORIDA PERMIT #. 56'5r- 1117 732 DEPARTMENT OF HEALTH Q ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM SITE EVALUATION AND SYSTEM SPECIFICATIONS APPLICANT: TNT Builders AGENT: Almatic Land Designs of the TC, Inc. LOT: 6 &'7 BLOCK:. SUBDIVISION: Sunset Park Subdivision PROPERTY ID #: 2430-501-0012-000-2 [ Section/Township/Parcel No, or Tax ID Number ] TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE,OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH.PAGE OF SUBMITTAL. COMPLETE ALL ITEMS. PROPERTY SIZE CONFORMS TO SITE PLAN: [✓] YES [ ] NO NET USABLE AREA AVAILABLE: 1.05 ACRES TOTAL ESTIMATED SEWAGE FLOW: GALLONS PER DAY [RESIDENCES-TABLET/OTHER-TABLE2 ] AUTHORIZED SEWAGE FLOW: GALLONS PER DAY [1500GPD/ACRE OR25000PD/ACRE ] UNOBSTRUCTED AREA AVAILABLE: SQFT UNOBSTRUCTED AREA REQUIRED: SQFT BENCHMARK/REFERENCE POINT LOCATION: ELEVATION OF PROPOSED SYSTEM SITE IS [INCHES/Fr ] [ABOVE/BELOW ] BENCHMARK/REFERENCE POINT THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER: 100 FT DITCHES/SWALES: 15 FT NORMALLY WET? [ I YES l✓] NO WELLS: PUBLIC: 200 FT LIMITED USE: 100 FT PRIVATE: 75 FT NON —POTABLE: 50 FT BUILDING FOUNDATIONS: 7 FT PROPERTY LINES: 11 FT POTABLE WATER LINES: 100 FT 'SITE SUBJECT TO FREQUENT FLOODING: [ ] YES [✓] NO 10 YEAR FLOODING? [ ] YES 1✓] NO 10 YEAR 'FLOOD ELEVATION FOR SITE: FT MSL/NGVD SITE ELEVATION: FT MSL/NGVD 1 VLY J118 1 MUNSELL #/COLOR TEXTURE USDA SOIL SERIES: 030020414 TO TO TO TO 10RF--3*"dl USDA SOIL SERIES: TEXTURE DEPTH TO TO TO TO TO OBSERVED WATER TABLE: INCHES [ABOVE/BELOW ') EXISTING GRADE. TYPE:[ PERCHED/ APPARENT ] ESTIMATED WET SEASON WATER TABLE ELEVATION: INCHES [.ABOVE/BELOW ] EXISTING GRADE HIGH WATER TABLE VEGETATION: [ ] YES [ ] NO MOTTLING: ( ] YES [ ] NO DEPTH: INCHES SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: DEPTH OF EXCAVATION: INCHES DRAINFIELD CONFIGURATION: [ ] TRENCH I I BED [ ] OTHER (SPECIFY) REMARKS/ADDITIONAL CRITERIA: SITE EVALUATED BY: DH 4015, 08/09 (obsoletes previous editions which may not be used) Incoipofated: 64E-6.001, FAC Page 3 of 4 . .•-1„ r r{� !. .f � ' S is �.. _ice '� 9"• a ;' ,}r • ._�' � , � ' � J,, ",y ail• —f 4 .3 r ' _ F� r'S 1 '�� I r. 48 Wit— y 5,� 2 i t '—1 E *' r' Edwards Rd `61.1-B t •, __ •! • Lam. � i y iT— , �,��, `y».'�ti-�'i'Iy S�I]T7»;p ��'J uu�G b� m�7adJ �ft Ldh9�a�lkb� ' i � ' • ! i _.— Custom Soil Resource Report St. Lucie County, Florida 2=Ankona and Farmton sands Map. Unit Setting National map unft symbol: 1)pty Elevation: 20 to 200 feet Mean annual precipitation: 49 to 58 inches Mean annual airtemperature: 70 to 77 degrees F Frost -free period. 350 to 365 days Farmland classification: Not prime farmland Map Unit Composition Ankona and similar soils. 50 percent Farmton and similar soils: 40 percent Minor components. 10 percent Estimates are based on observations, descriptions, and transacts of the mapunit. Description of Ankona. Setting Landform: Flatwoods on marine terraces Landform position{three-dimensional): Talf Down -slope shape: Convex Across -slope shape: Linear Parent material., Sandy and loamy marine deposits Typical profile A - 0 to 11 inches:. sand E - 11 to 38 inches: sand Bh - 38 to 48 inches: loamy sand Btg - 48 to 57 inches: sandy loam Cg - 57 to 80 inches., loamy fine sand Properties and qualities Slope: 0 to 2 percent Depth to restrictive feature: 31 to 50 inches to ortstein Natural drainage class, Poorly drained' Runoff class: High Capacity of the most limiting layer to transmit water (Ksat): Moderately low to moderately high (0.06 to 0.20 In/hr) Depth to water table: About 6 to 18 inches Frequency of flooding. None Frequency of ponding. None Salinity, maximum in profile: Nonsaline to very slightly saline (0.0 to 2.0 mmhos/cm) Sodium adsorption ratio, maximum in profile: 4.0 Available water storage in profile: Very low (about 1.5 inches) Interpretive groups Land capability classification (irrigated): None specified, Land capability classification (nonirrigated): 4w Hydrologic Soil Group: CID Forage suitability group: Sandy soils on flats ofinesic or hydric lowlands (G156BC141FL) 10 Custom Soil Resource Report Hydric soil rating. No Description of Farmton Setting Landform: Flatwoods on marine terraces Landform position (three-dimensional): Interfluve, talf Down -slope shape: Convex Across -slope shape: Linear Parent material, Sandy and loamy marine deposits Typical profile A - 0 to 7 inches: sand E - 7 to 34 inches: sand Bh - 34 to 50 inches: sand Btg - 50 to 80 inches: sandy loam Properties and qualities Slope: 0 to 2 percent Depth to restrictive feature: More, than 80 inches Natural drainage class: Poorly drained Runoff class: High Capacity of the most limiting layer to transmit water (Ksafl: Moderately low to moderately high (0.06 to 0.20 inlhr) Depth to water tab'le: About to 18 inches Frequency of flooding: None Frequency of ponding. None Salinity, maximum in profile: Nonsaline to very slightly saline (0.0 to 2.0 mmhoslcm). Sodium adsorption ratio, maximum in profile: 4.0 Available water storage in profile: Moderate (about 6.9 inches) Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 4w Hydrologic Soil Group: B/D Forage suitability group: Sandy soils on flats of mesic or hydric lowlands (G156BC141FL) Hydric soil rating: No Minor Components Electra Percent of map unit: 4 percent Landform: Knolls on marine terraces, rises on marine terraces Landform position (three-dimensional): Interfluve Down -slope shape: Convex Across -slope shape: Linear Hydric soil rating. No Waveland Percent of map unit: 3 percent Landform: Flatwoods on marine. terraces Landform position (three-dimensional): Talf Down -slope shape: Convex Across -slope shape: Linear Hydric soil rating. No 11 Custom Soil Resource Report Lawnwood Percent of map unit. 3 percent Landform: Marine terraces on flatwoods Landform position (three-dimensional): Talf Down -slope shape: Linear Across -slope shape: Linear Hydric loll rating., No 48—Wabasso sand, 0 to 2 percent slopes Map Unit Setting National map unit symbol: 2svyr Elevation: 0 to 70 feet Mean annual precipitation: 46 to 55 inches Mean annual airtemperature: 70 to 77 degrees F Frost -free period., 355 to 365 days Farmland, classification: Farmland of unique importance Map Unit Composition Wabasso and similar soils: 85 percent Minor components: 15 percent Estimates are based on observations, descriptions, and transacts of the mapunit. Description of Wabasso Setting Landform: Flatwoods on marine terraces Landform position (three-dimensional): Tread, talf Down -slope shape: Linear Across -slope shape: Linear Parent material: Sandy and loamy marine deposits Typical profile A 0 to, 6 inches: sand E - 6 to 25 inches. sand Bh - 25 to 30 inches: sand, Big - 30 to 58 inches: sandy clay loam Cg - 58 to 80 inches: loamy sand Properties and qualities Slope: 0 to 2 percent Depth to restrictive feature; 9 to 50 inches to strongly contrasting textural stratification Natural drainage class: Poorly drained Runoff class. Very high Capacity of the most limiting layer to transmit, water (Ksat): Moderately low to moderately high (0.06 to 0.20 inthr) Depth to water table: About 6 to 18 inches Frequency of flooding. None 12 Custom Soil Resource Report Frequency ofponding., None Calcium carbonate, maximum in profile: 5 percent Salinity, maximum in profile: Nonsaline to very slightly saline (0.0 to 2.0 mmhos/cm) Sodium adsorption ratio, maximum in profile: 4.0 Available water storage In profile: Very low (about 1.4 inches) Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 3w Hydrologic Soil Group: C/D Forage suitability group: Sandy soils on flats of mesic or hydric lowlands (G155XB141FL)' Other vegetative classification: South Florida Flatwoods (RI55XY003FL) Hydric soil rating. No Minor Components Hallandale Percent of map unit 6"percent Landform: Flatwoods on marine terraces Landform position (three-dimensional): Tread, tall Down -slope shape: Linear Across -slope shape: Linear Other vegetative classification: South Florida Flatwoods, (R155XY003FL) Hydric soil rating. Yes Boca Percent of map unit., 5 percent Landform: Drainageways on marine terraces, flats on marine terraces Landform position (three-dimensional): Tread, dip, talf Down -slope shape:' Linear, convex Across -slope shape: Linear, concave Ecologicalsite: South Florida Flatwoods (R155XY003FL) Other vegetative classification: South Florida Flatwoods (R155XY003FL) Hydric soil rating: Yes Pineda Percent of map unit., 4 percent Landform: Drainageways on marine terraces, flats on marine terraces Landform position (three-dimensional): Tread, dip, tall Down -slope shape: Linear Across -slope shape: Concave, linear Other vegetative classification: Slough (R1 55XY01 I FL) Hydric soil rating. Yes - 13 J- a