HomeMy WebLinkAboutPLANSGulf Coast Supply and MFG 5v Crimp Metal roofing FL #11451.12 Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11451.12
24 ga. 5v crimp metal roofing attached to plywood deck using #4 x 1.5" 24 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4' mde laps and C' end (type 2) 30 Ib felt underlagment installed with min. 4' side laps and 4" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c, at all laps and two etaggered rows 12" o.c. in field. Attach spaced L" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet dpeck to trusses using attachment detail on this sheet
12 12
4 SLOPE OPE 4
8'-I" T.O.B. 8'-I" T.O.B.
12" 2.
O.H;
5/8" thick light textured
stucco on typical concrete 5/8" thick x 8"w cut a
0 construction oral Flnls ed stucco bands
block c n tructlon c h
0'-0' = Finished Floor
0'-0" = Finished Floor
5/8" thick x 8"w cut FI sh Columns with 5/8" thick light textured Finish Columns with
coral finished stucco bands 5/8' thick cut coral stucco on typical concrete 5/8" thick cut coral
o bands
finish I �l NOTES: d stucco bands block construction finished stuccELEVATIONL��T ���Y�TiOREAR �LELEVATIONSCALE: I/4" = I'-O' E L E � A T I SCALE: I/4" = I'-O"
- Overhangs at I' O" unless otherwise noted on Roof Plan
dd Gulf Coast Supply and MFG 5v Cr;rap Metal roofing FL #II451.12
- R oof pitch at -T 12 unless otherwise noted 26 ga. Sy crimp metal roofing attached to plywood deck using #9 x 1.5"
_ wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
Gulf Coast Supply and MFG 5v Crimp Metal roofm FL #11651.12 Ang changes to this plan shall be submitted to the architect (type 2) 30 lb felt underlagment installed with min. 4 side laps and 4" and
PP y P laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
26 ga. 5v crimp metal roofing attached to plywood eck using #9 x 1.5" f Or a r ov a I I n W I t I n r i or t D start 1 n construction . apaced 4" o.c. at all laps and two staggered rows 12" o.c. in Field. Attach
wood screws with selF sealing washer at 12" o.c. max spacing over ASTM D p p g p 9 deck to trusses using attachment detail on this sheet
(type 2) ne lb felt underlagment installed with nd i aide laps and L end Return ALL S t e O Bands into Window or Door.
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails -
?aced L o.c. at all laps and two .staggered rows 12' o.c. in field. Attach
deck to trusses using attachment detail on this sheet
1/8' Thick cut coral stucco over paper
backed wire lath nailed to substrate through
one layer of 15 lb felt using 8d nails. Substrate
to be 19/32" CDX Plgwood nailed at 4' ol
in field and edges with IOd ring shank galvanized
. - nails into truss webbing.
.. 12
12 SLOPE 4
SLOPE "4
8'-1" T.O.B.
12"
H.
12 J
H. ❑ 5/8" thick x 8"w cut ❑ H. El
Cora
tors Finished stucco bands 3 O w� ® coral5finiishedic stucco bands
5/8" thick x 8"w cut 91
coral Finished stucco bands ®�
5/8" thick light textured
stucco on typical concrete
Wit
block construction F
-
---------------------------- - - - --- - - - ------_--_----_-----_ _ O'-O"= Finished Floor Finish Columns with arse iniFl
5/8" thick cut coral 5/8 thick fight textured -O'-4-A A.F.F..
stucco on typical concrete
RIGHT ELEVATION finished stucco bands � I block construction � I �%(�8-035`7
FRONT ELEVATION ATiOI�I .EVIEWEDFOR
. L_: DE COMPLIANCE
SCALE: 1/4" = I'-O" SCALE: 1/4" = I'-O" ST" LUCIE COUNTY
BOCC 'i>-
ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP.
Product Approval Submittal Affidavit
Opening Schedule Swing Doow,
Overhead Doors, Sliding Doors, Windows B Skylights
Opening
Type
NOA/P'L
NUMBER
Product
Model #
Manufacturer
Glass
Attachment method
E 8uation
Design Pressure
of Approved Teats
1,2,3
$4
FLU 239.3
Single Hun
g g
SH-100
Impact
PG f
5/I4"
I/4" ildia• tapeaRs t min. I . C penetration to be
min.spacea par product approval. Contractor shell adhere to
min. edge distances specified in Product approval
+ 80.0 PSF
-
A
Id-0330.02
Overhead
Garage Door'
Model 824/811
9'-4" max, Width
IL'-O" max height
DAB
- ^-
�is6�hsr""srtp eie`�°. �•i+1Md aww s"tr� eu'�►`
Imes x r 5ir"ria t6r"sd It rsr... m sseh srairt � s
olw
min. "r er.rm. - oe e" ■riaq .sin" to sredet gprWftL
10-9-21
+ 50.0/-40.0 psP
B
FL# ILL14.1
Fiberglass
gmomogth Pro/
Jeld-Wen
Elco 1/4' din. tapCon with min 1.25" eabedment at 3' max
from corners and 1.5' o.c. max. thereafter in hand and iambs
+ 50.0 PSF
C
FLU 251.5
Sliding Glass
g
Door
Series 110
SGD
PGT
I" nom
Type "CsSA"
IM" die. tapeoRs w/ min. 1 3/4C penatretio� ta ba
apaced par product approval. ontractor s all adhere to
min. 2 I/2 edge distances specified in Product approval
± 60.0 PSF
Product
NOA/FL
NUMBER
Model #
Manufacturer
Attachment Method
TEST
Expiration
Date
Design Pressure
of Approved Teats
Mullions
FLU 241.1
1" x 2 3/4'
x .315"
PGT
Install per fastener type and spacings shown in Table IA and IB
in product approval on sheet 5 or 22.
+ 58.0 PSF
Roof
FL# 11651.12
SV Crimp
Metal Roofin g
Gulf Coast Supplg
and manufacturingItilpe
2L pe. 5v trimp metal roiling attached to plywood deck umng #9 x 1.5'
wood screws with self sealing washer at 12" o.c. max soacing over ASTM D
W 30 lb fait underlayment installed with min. 4 ,de taps and I.' end
laps fastened with conromon resistant tin ceps and uath 1.25" ring shank narb
?dead L o.c. at all laps and two staggered rows 12' o.c. in add. Attach
dick to trusses using attachment detail on rod plan
- 108.5 PSF
Siding
stucco on Block
Soffit
FL# 12198.3
Model T4 12" vented
yin I Soffit
Kaycan
Install 2" x 2• battens at L" o.c. screwed to soffit framing using
#8 x 3" wood screws at each truss. Install soffit to battone using
0 r)" dn x 1.5" Iona ring shank nails with S/8' dia d.
+55.0/-35.0 PSF
Hurricane
Panels
I have reviewed the above and approved it
by my seal below. ( Architect or Engineer
of Record
AND WiLL CONTINUE 1=0R ONE YEAR 1=ROM THAT DATE
I/2" drywall ceiling on trues bottom cord
2" x 4" top p to
I/2" drywall on
2" x 4" studs at I6" O.C.
base -board 2" x 4" P.T. bottom plate
�:LY:� `ski:f�lin..i'i'::1..�'i'r.i:�i./..::.,:'y�.•y 1. i.{':...,.-.'�.'�.
4" concrete slab with fibermesh OR
4"xV #10/10 WWM on L and Visqueen over
PERMITTING INFORMATION (FORM 100)
Florida Building Code Residential: Lth Edition and ASC£ 1-10 for Wind Loading
Building Design is: Enclosed Risk Categorg: II Wind Velocity: 145 mph ultimate
Mean Roof Height: II'-qq"Roof Pitch: 4.12
oor.
Internal Pressure Coefficient: ±0.18
SubJectability to damage from. Weathering: Negligible Termites: Veru Heavu
Width of Roof End Zone: V-4" Wind Speed: I65 mph ultimate
Wind Exposure Classification: C
1.21 x O.L = 0.12G
Adjustment factor for Exposure Height: ASD design
SCANNEL)
Load Combination: ASCE 1-10 Section 2.4 DL+LL; DL+O.LWL; O.LDL+O.LWL
Components t Cladding Wind Pressure (NET) Roof Zone: 1. +20.0-32.6 pat
BY
Roof Zone: 2. +20.0-51.0 pat
St. LucieCounty
Roof Zone: 3. +2O1/-84.0 psP
Components t Cladding Wall End Zone Width: 3'-4"
Components t Cladding Wind Preswre (NET) Wall Zone: 4. +35.8/-38.1 poll
0 = Roof Zone 1
Wall Zone: S. +35.8/-41.8 psf
Walls Zone 4
Components t Cladding Wind Pressure (NET) on Garage Door: +32.0/-40.3 Pat
Shear Walls Considered for Structure? Yes
Continuous Load Path Provided?
®= Roof Zone 2
Walla Zone 5
Are Components an Cladding Det� Provided?Yes
END ZONE
Minimum Sal Bearing Pressure: 2S00 psi, Presumptive: X By Test: psi
liqlill
SEE RODUCT APPROVAL FOR IMPACT P O ECTION F R O E INGS
= Corner Zones
Roof Zone 3
ROOF LIVE LOAD: 31 poll ROOF DEAD LOAD: 10 pat
/167
FLOOR LIVE LOAD: �- pat FLOOR DEAD LOAD: 1O sf
19�_ _J
clean compacted termite treated fill
Interior Non -Searing Partition J.0 1 SLANDIA l.ANir
nta JOB ADDRESS:
Braden it Braden AIA, FA lUMODEL- Date Drawn Revisions Sheet Comm #
Ar hitects - Planners ynne Building Corp. Grr. 5-24-18
,41 S.E. Coconut Avenue THE STERLING P�£� Drawn by: 1. 16 - 3 O 1
T I (712) 287-8258 C.C.U.
II : (112) 281-8283 RIGHT FILE COPY B
E-m mil: bradenala�comcast.net Spanish Lakes Checked by:
St
Stuart 3499G #AAC000032 . Lucie County Florida D.R.B. OF 5
rFLOOR PLAN CRASH POST DETAIL REA CALCULATIONS 2" l0'-0" I " 10'-0" 14'-0"
TYPICAL NOTES: SCALE 114" = I'-O" N.T.S. Living A/C = 1,414 sq. ft.
I. Contractor to verifyALL notes and dimensions prior to steel
high by 4" diameter Front Porch = 1�3 sq. ft"
p steel crash post. Floor
proceeding with work. Flange with 4 - 3/8" Rear Porch = 116 sq. ft. Opt. PATIO/SLAB
ex anslon bolts Into arage = 321 sq. f t.
2. Contractor to STRICTLY enforce ALL OSHA Requirements, slab (3/8"t 50 ksi steel plate)
3. ALL Lumber to be used as Beam, Rafters, etc... to have To al Under Roof= 2,124 sq. ft.
a minimum 1,400 P.S.I. fiber stress. `
4. No dissimilar metals to touch. 2" 2'r,° To al Cubic Ft = 11,792
5. ALL Concrete used for slabs shall be min. 2,500 PSI concrete. �" I
2" VTR
ALL Concrete used for vertical filled cells, cont. tie beams etc., to ° EGRESS O
O
shall be 3,000 P.S.I. concrete and/or 4,000 P.S.f. grout mix '3/e" 2i/," block
x rz" Concrete column
6. Drywall at ceilings shall be leveled and attached to bottom chord 4" 2 �" I m i block filled with concrete and
of trusses with screws per FBC R102.3.5. o O 1 (2) lintels
above
bare vert. tied Into
1. ALL wood in contact with concrete shall be pressure treated. 1
1 Covered Porch °
8. ALL wall dimensions are nominal and not finished wall or stud dimensions. '�' � vTR
O
9. ALL plumbing fixtures to be low flow. Masterr' I If
10. Contractor to Provide Drain at water heater in accordance Bath ka
00 ° O ° O DOwith the current edition of the Florida Plumbing Code. ° 11. Contractor to Provide a 2'-8" wide door at one bathroom for 2" 2,, n MASTER ° lm
handicap accessibility requirements. �" r," VTR °BEDj�•�•QQM u12. Lowest finished floor to be set b Governin Buildin De artment '-o°to 9'-8" A.F.F. W "mBa u-y g p JIL Vault d Ceiling 8' lat A.F.F. '+ F oasurveyor to set in field. IFlat Cedmg xv)
13. Separation between residence and garage shall be per FBC R302.6 ��i G EAT C9
14. Door between garage and residence shall be I-3/4"t 20 min. rated door iOOMWater Heater I 115. Wall and Ceiling shall have a flame -spread classification of not greater than 200 per FBC R302.9.1 . 116. Wall and ceiling finishes shall have a smoke -developed index of not greater than 450 per FBC R302.9.2 I Rod Shelf11. All exposed attic insulation materials installed on attic floors shall have a critical radiant i" x 4" P.T. Buck nailed to Masonry Beam -flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation block with case hardened nails we. �" 4'-0"rior to door attachment materials exposed on the underside of the roof deck or on the attic walls shall comply p saw. a I amity to be H B
with F.B.C. R316 - see permit info box of code edition :.:....:.....:.::, 3 "r `� I - v Y, high
18. Gyy sum board material shall conform to ASTM C36, C-19, C415, C514, C630, C931 :°; ''';- ':` :;, n 8'-O" to 9'-8"A.F.F. 2" x L" knee -wall I °
C40, C1002, C104-f,C11-17, C1118, C12-18, C1395, or C1396 and shall be installed C.O. Te Septic Vaulted Ceiht� below counter top ge 1 Mrr
according tothe following: (FBC R-102.3.5) L SET °
IN RISER DfNIN4 1
Drywall
Thickness
Location
Orientation
Framing
Member
Max. spacing
of fasteners
Nail sizing options for
g p
installation of drywall into
Spacing
Maximum
wood framingmembers
2" x min. thickness
Nails
Screws
Ceiling
Perpendicular
24"
1"
12"
13ga 1 3/8' long with 19/64' head
0.098" diameter x 1 1/4" long
annular -ringed or 5d coder nail
/2
Walls
Either
1L"
8"
IL"
0.080" dia. x 1 5/8" long with
Direction
15/64" head
OR
Ggpsum board nail 0.080 dia.
x 1 5/8" with 9/32" head.
Ceiling
Perpendicular
24"
1„
12"
13ga 1 5/8" long with 19/L4" head
0.098" diameter x 13/8" Iong
annular -ringed or 4d coder nail
If
e
Walls
Either
„
IG
8 "
IL"
0.092" dia. xx I 1/8" long with
Direction
1/4" head
OR
Gypsum board mail 0.0915" dia.
x 11/8" with 19/G4" head.
PLUM�3 _
Install SGD thru buck into u O 0 ROOM �a .e all Rod Shelf ASINET
LINEN
block with 3/I4" tap -con with I s r O I O G
1 1/2" penetration at 4" o.c. max. I mob i "---� r
from each corner and 20." o.c. max ° �' \°jam _If
thereafter at head per product approval ® - a
i \ I s
I" x " P.T. Buck nailed to O Vanity to be 1 i ° B A T ° O
bloc with case hardened nails ' 34 Yz high H
Head prior to door attachment O 13'-03/�" I 9Y," (41") ° i OLn
High Wall ,
KIITCHEN=
fixed door '%':`:d::;;. iv hu 1_1 Vent ryer
- J iv throug wall
Over ang 8'-0" A.F.F. i
Use 3/I4" tap -con with sliding door :�;<;::;;��, -
'` Flat Ceding
1 1/2" penetration at L" o.c. max. °
from each corner and 20" o.c. max n Masonry W II ^: H _ 4'-I" 10`
thereafter at sill per product a prove!
„• _
I i/2" r+ Upper cabinets to �
17'O 10' 2" 4" O" extend over ef. iy
Bottom Track Typical Flooring 1 cv I " fillervt
Sill Install SGD thru ck into u' BATH _ a 4'-O"
block with 3/I6" t ip-con with - v - ap""
Z I
19. ALL ceramic tile surfaces installed shall conform to ASTM A108.1 thru A108.6, S l l d I n g D OOr D et a l l From
penetration at L" o.c. max. °
A108.1, All8.i, A118.3, A136.1 and A13�.1 from each corner nil 20." max Rod i SheIF
thereafter at Jam per product approval t+ 18 c`ry 1 -n 6a mwlauon ° A/C O
20. Cement, fiber -cement or glass mat gypsum backers In accordance with ASTM At Masonry Wall NTS ;�, _ J 4") steel Ballard
C1288, C1325, OR C11�8 and Installed I.A.W. manufacturers recommendations shall i F L I lu I ee ciao an this shoat #I
be used as backer for the wall the in tub areas and wall panels in shower areas. I I r y� III
W I 1 I d O W S e h d u l 1 -L 11 r " 1 Provide auto
22 x S4
21. Insulation includingfacings such as retarders or vapor permeable members Installed O I Attic Access I closer O
within floor-ceilinassemblies, roof -ceiling assemblies, wll, crawl spaces and attics PRESSURE ZONE q�- e'-a' A.F.F. a with I'
- a c Flat Ceiling - - 22" L - - - - -
shall have a flame spread Index not to exceed 25 with an accompanying smoke Mark Size Rough Open. Window Description U U -
developed index not to exceed 450 when tested In accordance with ASTM E 84. 1. 4'-5Ya"x 5'-3ia" 54ka"x L3i/," Single Hung ZONE 4 f- In • 13'-G" m L'- LA - 4 m 15Panel P Meter
Insulation shall comply with F.B.C. R316, 2. C-2Ya"x 5'-3%s" 15" x L3%;' Single Hung ZONE 4 u m SECOND
3. 2'-2" x V-2 1/2" 21%2"x 38 is" Single Hung ZONE 4 N BEDROOM E GRESS RG Y GARAGE
NN
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11451.12 4. 4'-5Ya"x 4'-2%" 54%s"x 54�e° Single Hung ZONE 4 ° O T DO 8'-4" A.F.F. O O
24 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5" ° Flat Ceiling
if
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. a side laps and L" end ALL Windows t0 be aluminum windows w/ tint 0 -
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails and mullions per elevations.
s aced L" o.c. at all laps and two staggered rows 12" o.c. in field. Attach p
dpeck to trusses using attachment detail on this sheet ALL windows t0 withstand pressures In permit info b0 On Sheet I
p EGRESS r-----------------i O
ALL windows in bathrooms to be tempered Block wall in I i
All rough opening dimensions to be verified by contra for ° M ° garage to be 1 `�
with manufacturers specs prior to construction I struck block 1
Simpson HETA 20 or equal 12" x 12" concrete column block filled CC VER D I 1
hurricane anchor at each truss 12
with (10) 10d x 1 1/2" nails PRE-ENGINEERED TRUSSES ��-•�) �` I I o
l 24" o.c.) su portrn Max. �•✓ loof S c h d ui a with concreteintodlintela#above v rt. tied ORC
ISlo1bs. uplift g 1 F at 24 o.c. TYPICAL a L" IT-4" T- 21
(shop drawings by manufacturer) DO rI I
Mark Size Rough Opening Door [Description PRESSURE ZONE
A q'-O" X �'-O" 108" x 84" Overhead Garage Door zoxE 4 N ° ° O ° °
R-30 blown fiberglass „ a „ °
Aluminum Drip �� in bottom chord of trusses B 3'-O" X L'-8" 41 /, x 83/, Fiber lass Panel - Inswing ZONE 4
Edge i Fascia 9 9 4'-4" 5'-2' 2'-e" 2'-8" 3'-5" 9'-0" 3'-5"
< 1/2" drywall with smooth finish C C-O" X 11 14" x 81 %s" of K Sliding Glass Door ZONE 4
2" x L" Sub -Fascia Two rows of beam block filled with concrete " 5'-4" 01, 15'-ID"
and (U 05 bar Cont. in each row. Substitute D 2'-0" X 6'-8" Solid Core - Wood - L-Panel -Bi•-Fold Fin hed 24 x 81 /2
Kaycan full c vent vinyl aoffm installed precast lintel filled with concrete and (1) #5
using 1/8' dia shank x 1.5' long gaiv. bar cont. for bottom row over openings E 2'-4" X C-8" Solid Core - Wood - L-Panel 36 -
rooting nails with 3/8' die. head per
product approval - ace chart sheet #1 1/2" drgwall over IN x furrin F 5'-O" X L'-8" Solid Core - Wood - L-Panel - Bi-Fold
strips at IL" o.c. with R4.1 ?,-Foil
Insulation on tgprcal 8" Block walla G 2'-8" x 6'-8" x I s/," Solid Core Woad, Steel, or Masonite Door
5/8" thick light textured All drywall to be installed per FBC R102.3.1
stucco on typical concrete T and shall meet all pertainingg ASTM codes. H 2'-8" X 4'-8" Solid Core - Wood - L-Panel
block construction M Mortar to be Type "M" oniy proportioned per FBC R601.1 Install windows thru buck into
and Mortar Jonts shall comply with FBC RL01.2.1. J 2'-L" X L'-8" Solid Core - Wood - L-Panel - Bi-Fold block with 3/10 tap -con with
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...) 1 1/2" penetration at G" o.c. max. Attach buck to block wall with
K 2'-8" X L'-8" Solid Core -wood - L-Panel - Br -Fold From each corner and 20." o.c. max 1/4" die. Elco cone screws with min.
#5 bar vert. w/ thereafter at .lambs and 20" o.c. max. 1 1/4" penetration at 12' o.c. max
30" overlap Fill tail with concrete and ,_ „ a Exterior face at head and sill per product approval and 4" max from each corner thru
at each filled cell (U #5 bar vert. (t ical). I 6 X L -8 BI-FOLD 2" x G" PT Buck
9P 7"lock
x 4" P7 Exterior face
Max spacing shall not exceed of wall
4e" winless otherwise noted ALL Exterior doors to withstand pressures stated in permit info
Wood see foundation plan notes for box on sheet #I
Base 7LOerica
spacing at openings ED
4" concrete slab with frbermesh OR GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORMA SHALL
11 #10/10 WWM on L mil Visqueen over WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX O SHEET #1 Buck nailed to INSTALL VULKEM BLOCK SEALANT #8 Wood screws thru Jamb into buck
clean compacted termite treated fill case hardened nails ON ALL JAMB, HEADER, AND at each hinge and 15' o.c. max and
' All rough opening dimensions t0 be verified by contr for Detail at Windows Prior to window attachment INSTALLATONRIOR TO BUCK Detall at Door prior to door attachment
Grade t L.i ,.., ,_ ..............
with manufacturer s specs prior to construction NTS NTS
- =111 Date Drawn Revisions Sheet Comm #
1�I=IIII _ -III IIIIE IIII- Braden Braden ,41,4, ',4 Wynne Building Corp. 5_24_18 REVIEWED FOR
I 11 I II EE I I=_II I III - 111111 Ar hitects - Planners
1111 14" x 14" Concrete foaLin�a •41 S.E. Coconut Avenue �• S T L I i� C.rt REAR Drawn by: CODE COMPLIANCE
14" with (2) #5 bars cunt. an #6 T I (7�2) 287-8258 PORCH LUCIE COUNTY 16-301
TYPICAL SECTION transverse bars at 48" o.c. C. C. U. ST•
Pa (712) 28"I-8283 RIGHT gOCC �
E-m III: bradenaia9comcast.net Spanish Lakes Checked by:
Scale I/2" = I'-O" Stuart 34996 #AAC000032 St. Lucie County Florida D.R.B. OF 5
sTlzucTurttell,AL_
>�
I. ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL 8.
SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY
BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM
FROM HOUSE TO DRAINS (iF PROVIDED) PER PLANS
CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN
PROPER ENGINEERING DATA FOR DESIGN.
2. ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSI AT 28 DAYS 9•
DESIGN LOADS ARE AS FOLLOWS:
ROOF (DL+LL) = 41 PSF
ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI
WIND VELOCITY = PER PERMIT INFO BOX ON SHEET 41
BE 3000 PSI OR 4.000 PSI GROUT MIX AT 28 DAYS
EXPOSURE ="C"
3. POISON SOIL AND COVER W/ 4 MIL. V►SQUEEN WITHIN 24 HOURS. No
SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION. 10•
ALL REINFORCING STEEL SHALL BE GRADE 40, MEETING ASTM A-14, E
4 GROUND FLOOR SLAB TO BE A MINIMUM 4" THICK W/ 4X4 10/10
A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 301 STEEL.
WELDED WIRE MESH REINFORCING ON 4 MIL. POLYETHYLENE VAPOR ON BARRIER
TREATED, CLEAN MACHINE COMPACTED FILL 11
ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR
(MINIMUM 5%E DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH
BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRE
MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH.
BE
FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS,
SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE.
5• LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS
BEFORE FILL IS BROUGHT IN. FILL MATERIAL SHALL CONSIST OF 12.
CLEAN GRANULAR SAND CONTAINING LESS THAN 10% MATERIAL
MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
PASSING THE US STANDARD NO. 200 MESH SIEVE. PLACE
FOOTING: 3"
STRUCTURAL FILL IN LOOSE LAYERS OF 12" IN THICKNESS AND
BEAMS: 1-1/2"
COMPACT EACH LIFT TO AT LEAST 95% OF ITS MODIFIED DRY
PROCTOR VALUE. 13.
LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS.
6• GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND 14.
USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF 1400 PSI
DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE
ATTENTION OF THE ARCHITECT. 15
ALL STANDARD LUMBER SHALL BE SYP WITH A MINIMUM Fb OF 1000
PSI OF NO.2 SOUTHERN PINE, UNLESS NOTED OTHERWISE.
l• GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER
FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR 16.
ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL B
PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING.
FOUNDATION FLAN
I. Any changes to plans must be submitted to the architect SCALE: 1/4" = 1'-0"
for approval before proceeding with construction.
2. Contractor shall be responsible for verification of all
Termite Protection for New
notation and dimensions before starting construction.
Construction.
3. Soil conditions assumed to be 2500 psf. Should any other conditions be
encountered, the architect shall be notified in writing for revision
Soil treatment used for subterranean termite
after
a
inside the foundation perimeter shall be done after all
all
'4. Verify all recess thickness at showers, tile, etc.,..
excavation, backfilling and compaction is complete.
S. Contractor to provide filled cell with concrete and I US bar
vert. at -48" If soil area is disturbed after initial chemical soil treatment
o.c. max. Provide (1) filled cell on each side of Openings upp to
S'—II" Wide. area shall be re -treated with a chemical soil treatment
Provide (2) filled cells on each side of openings from 6'—O"
to cl'—I1" including spaces boxed or framed.
and Provide (3) filled cells on each side of openings from 10'-O"
and up Treatment must be in accordance with the rules and laws
Contractor to see plans for any other condition used. Foundation
Walls established bg the Florida Department of Agriculture and
shall have filled cells at 24" o.c. unless otherwise noted (see
section) consumer services.
6. Contractor to provide for Form Board Survey — Form Board
Survey Protective sleeves around metallic piping penetrating
to be provided to Truss Company prior to truss construction
concrete slab on grade floors shall not Be of cellulose
1. Contractor to provide for soil test prior to construction and
provide containing materials and shall receive application of
a copy of sort test to architect for review prior to construction
termicide in annular space between sleeve and pipe.
8. ALL Reinforcing steel shall be grade 60, meeting ASTM A-16
and
A-35 specifications. ALL Anchors to be A-301 steel.
9. Provide a minimum of 3" concrete protection at footings and
1-1/2" concrete protection at beams for ALL reinforcing bars.
#5 bar vert, w/ Thicken edge to
8"x8"
30" overlap SEE TYPICAL with concrete and 4" concrete slab with fibermesh OR
at each filled cell ECTIONS one 95 bar continuous VY4" #I0/10 WWM on IO mil Vrsqueen over
clean compacted termite treated fill
°
4" concrete slab with fibermesh OR GRADE
vxC #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
—
Grade
Ilii
II—
NAIL I, ;...:; ":=•.::. ::.,.".:':r..•.::.,-:'...
-i ii
W E
RC
POH
SLAB EDGE DETAIL
14% x 14"d concrete monolithic
footing with (2) #5 bars cont.
SCALE 1/2" = 1'-0"
14"
95 bar Vert. w/
TYPICAL FOOTING DETAIL 30" overlap
SCALE 1/2" = 1'-0" at each filled cell
SEE TYPICAL
-,,,-SECTIONS
4" concrete slab with fibermesh OR Ad, curb heightFilled
Cell Masonry Column Wi
h One
CxC 410/10 WWM on 10 mil Visqueen over based on gar. floor
4" concrete slab with fibermeah OR #5 From Footing To Tie B
am
clean compacted termite treated fill slope.
JjJVx6" #10/10 WWM on 10 mil Visqueen over Conc. Fill To Be 3000
SI
#5 bar cunt. 45 bar in curb\x
T clean compacted termite treated fill See Floor Plan For Loeati
O'-o" a P.P.
Step per Grade
;.a foundation plan
=
`r' •;'
,..
O
ITr"`
III
~' d0
Sin le i illed Cell Col
Filled
mn
10" (2) #5 bars cont. bottom steel
14% x 14"d concrete monolithic
ITS
footing with (2) #5 bars cost.
12"
14"
v
2" 10'-O" 12"
14'-0„
— — — 10'-O' — —
—
I � I
I � I
10pt. PATIO/SL.Atp
M.
Is
FI
I
i I
-
os
Rear Patio/Slab
r
I 11 to be poured separate I
I F4 1L from the house slab.
a
°
O
I J 4 Thicken footingg to
N 24"w x 14"d x 24"L I
FI
L 7 under filled cells
- ° under girder bearing. I
°a o 0 00 a ° ° I N I
° r Rear Patio/Slab to I
E
be flush with bottom of
-
FI sliding door recess. I
U z
Slope 1/2"
-
vvCL
_ Iro
—a I I
~
LQ
LL
I
I
-i I I
I
of
FI I
o I
I I
e
I
Vanitg to be I
4" concrete slab with fibermesh OR 3'4 igl
O I
H B
CxC UIOAO WWM on 6 mil Visqueen over �1
I clean compacted termite treated fill
D
I
°I I°
I
I
F
I
f-
L
°
_a
Ln
°I I°
I I
I
O O a
I f
r - - 4"4 steel Bollard
W_/ I efilled Concrete
°
1 w/
1 g* I I 5
�=°p IO
V
�°13.
I FI I I mNE I
r
LLN
I I I ,J ? a�
! E� I
L
I
I1
_
N
.� ry
_
re
i
CD
e
I
O
° ---_—_ o I
If
_—_—_00
T °
° 1]o O I I I I 1 I ,1' q� U
I QI
yr
UJ wxc;
v` I
LU X I°
p
O
in
fin
r Recessfor
c_v
0� — — — — — — — — ° I — —4 — �� ° Ga age ° J
�O
,
12"
x 12" concrete column block filled
wi
h concrete and (2) #1 bars vert. tied
into lintels above
3'-5"
9'-01,
W-6"
3'-4"
5'-4"
t 2 DETAIL AT GARAGE STEPDOWN
Filled Cell Masonry
Column Will
One
SCALE 1/2" = 1'-0"GARAGE CURB DETAIL
nFSConc.
#5 From Footing
Fill To Be
To Beam
3000 P
ach.
31 I
12' x 12" concrete column SCALE 1/2" = 1'-0" See Floor Plan For Locatio
block filled with concrete
and (2) #1 bars wart. tied
into hotels above Verify house slab
height in field
Top of Tooter Y s
I6 below finished floor •r,.
ic" r r .. _� Ili .�t, i^a'--;ti•
Double Filled Cell Co umn
TS
FOOTING
SCHEDULE
Mark
Size
peso
Iron
FI
14"W
x 14"D
MONOLITHIC FOOTING
WITH
2 #5 BARS CONTINUOUS
12"W
X 12"D
MONOLITHIC FOOTING
WITH
(2) #5 BARS CONTINUOUS
Q
30"
x 30" x 1601)
COLUMN FOOTING WITH (4)
#5 BARS EACH WAY
F®
8"W
x 8"D
THICKEN SLAB EDGE
WITH
1 #5 BAR CONTINUOUS
F5
14"W
With
x 14"D
Curb at Garage
MONOLITHIC FOOTING
WITH
2 #5 BARS CONTINUOUS - CURB a 0'-0'
30"x30"xl6" concrete 2" x L" PT wood secured with
III I�III column footing with (4) 3/8"dia. x 6" anchor bolt at 18" o.c. Braden Braden AIA, FA nne Budding Corp.ate Drawn Revisions FOR Sheet
#5 bars each way overhead door track secured to wood Ar hitects -Planners — 9 P 5-24-18 REVIEWED Comm #
jamb per manufacturer's product approval
3O" Garage Door Jamb Detail B4 S.E. Coconut Avenue THE STERLING PORCH Drawn by: CODE COMPLIUNTY
T : (112) 281-8258 C.C.U. ST.LUCI►ECO 16-301
GARAGE DOOR TO WITHSTAND PRESSURES STATED Fa : (112) 281-8283 RIGHT
3 COLUMN FOOTING DETAIL IN PERMIT INFO BOX ON SHEET 41. SEE PRODUCT NTS E-m il: bradenaiaecomcast.net Spanish Lakes Checked by: BOCC
SCALE 1/2" = 1'-O" APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL. Stuart F 34994 UAAC000032 St. Lucie County Florida D.R.B. OF 5
Provide #5 bare with min. 48 bar
diameters overlap Into beam. Tie
Provide #5 bar act in pre -cast
ROOFSHEETING
filled cell steel Into continuous beam block steel.
lintel Into beam where length of
the opening calls for it.
Simpson HETA 20 Strap truss to wall using Simpson MGT with
Provide Cast- rote
s.
8US-OB/OT recast
lintel set in mortar
Mmi_earin
- ...
KellArea
Edge
Field
Fastener
--IT—
Pre re
Zone I
1
4,,
8d ring shank
45 psf
Zone 2
-411
6"
8d ringshank
16 psf
Zone 3
4"
4"
8d ring shank
84 psf
** Zone 3a
6"
6"
#8 wood screw
112.5 psf
Provide PT Buck
attached per �emb
details into filled cel
it:T,1
4" Pre-castBill
r;.,
1;111l,I
t .I
Cr,. •I
F;..4�
-
hurricane anchor at each truss
5/8'
dia.
threaded rod with min 12" embedment
( 24" o.c.) supporting Max.
pp g
into
(22)
beam
10d
either wet set or in epoxy with
nails into truss. Add blocking to
1810 lbs. uplift ETA 20
truss
leg
per detail on this sheet
Poured Filled Call
O
Provide U5 bare with min. 48 bar
diameters overlap in Pilled call. Tie
Pilled call steel into continuous
rooter steel. U.I
** Use nails or s(;rews based on Ares ure for roof stated I Scale: 1/2" = I'-0"
in permit info box on these plans or zone 3 CBS WALL
SINGLE PLY REAR GIRDER TRUSS
Nail 2" x 4" blocking to Vert. leg of ^
truss with IOd x 1.5 nails at 4" o.c. 111
Verify with Plan
v Install Simpson MGT into wall using =3
Concrete 12 "x 125/8" dia. threaded rod set min. 12" Q+'
Lintel Column Block into wet beam and (22) IOd nails into truss QL U
_r E
# (J[ :3)
Rebar -"` 111 U-"
Rebar 48 Bar Dia. LU O O
Min. Overlap TRUSS BLOCKING DETAIL Q
Column to Lintel Attachment AT GIRDER STRAPPING w
AT CENTER BEARING POINT LU
NTS who
1/8" thick light textured stucco installed per V
ASTM C 924 over ASTM D type 2 paper backed LL a
wire lath Walled to2 substrate through one layer of —
ASTM D Type 2 felt paper using ed Halls. Substrata
to be 19/3� CDX Plywood nailed in 6" ods in field
and edges with IOd nag shank nails into studs. "�...,
Mark Size and Description Aluminum Drip
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11451.12 Edge t Fascia
Two rows of beam block filled with concrete and 1 #5 bar 26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
BI continuous in each row. Hook vert. bar over top bar with �'
#5 90° bend bar with a 10" min. la at to bar. (type 2) 30 lb felt underlayment installed with min. 4 aide laps and L" end
p p laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails Flash and Counter Brace Gable end
s aced 6 o.c. at all laps and two staggered rows 12 o.c. in field. Attach flash Brace Gable end with 2" x le and #2 min.
dpeck to trusses using attachment detail on this sheet
with 2" x 4" SYP #2 Oft back nailed to bottom
Nail ledger to 8ft back nailed to bottom of top chords using (2) IOd
Additional Precast Lintel ❑ n " gable end truss of top chords using (2) IOd nails at each truss
#5 bars Lintel Bar Clear A B with 12) IOd ds nails at each truss
Len th Len th S an Bars Bars at each web
1 ':M: • ' I 1 I 1 1 21-101, 2'-8" 1'-V 2,43 none
1 ' •i" 1 1 1 1 1
31-4" 3'-4" 2'-2" 2,#3 none
BFe-OBAT BF8-IBAT 8P8-IB/2T 12
Additional 4'-O" 3'-10" 2'-8" 2,#3 none Simpson HETA 20 a equal 4 PRE-EN44"o.c. Y WOOD TRUSSES
£ #5 bars hurricane anchor et each truss s 24"o.c. TYPICAL
CLEAR �;.;, •, - 41-6" 4'-4" 3'-2" 2,43 none with (10) IOd x 1 1/2' nails
no Row of "H" ;:`% _"': ( 24" o.c.) supportmg Max. p 9 y
810lbs. uplift ( shop drawings b manufacturer )
L•'.;,,t Block Above 5'-4" 5'2" 4'-0" 2,43 none
y h::
-10" 5'-81, 4'-C 2,#4 none
r ' , ! ,f'• y Precast Lintel N
1 ' 6'-6" 6'-4" 5'-4" 2,#4 none Aluminum Drip p R-30 ble n fiberglass
1 , Additional � P1/2m in bottom Nord of trusses Q
Is.---- i #5 bars �� Edge l Fascia attached
hed stucco nt 3and vertical
lath F.
�'-O" 6'-21, 2 u5 none attached to horizontal and vertical good ;
12 framing with Wads ar eteples to provide - I/2' drywall with smooth finish LU
BFIL-IB/IT BFI6-IB/2T no lea than 1-3/4" penetration into
2' x L' Sub-Fasci =
8'-4" l'-10" 7'-O" 2,#5 none into Her wood framing and 3/4" penetration Two rows f beam block filled With concrete
NOTES: into vertices wood framing member. and (1) #5 bar cont. in each row. Substitute
I. min. coverage of steel=l.5"
2. min. bearing required 9 on, end=8" ALL reinforcing steel is grade 60. Kaycan full o vent vinyl soffit metalled precast . el filled with concrete ands #5
3. standard for remf. steel=ASTM A4I5 using 1/8' dia shank x I5' long gals. her coat. r bottom raw over openings
TYPICAL LINTEL SECTION roofing nails with 3/8' da. t s per "
Product approval -ass chart ,heat #I " I/2 drgw II over I x furringg
( PRECAST CONCRETE) 5/8 thick light textured strips ai " o.c. with II rrfod
stucco on typical concrete "
12' X 12' concrete column block construction insulation n typical 8 Block walls
o
LINTEL SCHEDULE
Mark
Window
or D
Unit
Width
Lintel
Size
Cast -Crete
Specification
Rows of
'H" Block
Above
" "
Bottom
Steel
Size
Top
8tael
Size
Max.
Gravitg
Load
(PLF)
Max.
Uplift
Load
(PLF)
Max.
Lateral
Load
fPLF)
L22
2'-2'
V-6'
8F8-OB/IT
I
#5
30119
1569
1024
L31
2'-L'
3 _8•
4'-0'
BF8-OBAT
1
45
25LI
1363
113
L46
4'-6'
S'-10"
8FB-OBAT
1
#5
1105
909
339
LBO
5'-O'
L'-0
8P8-OB/IT
1
#5
1238
836
121
LLO
L'-8"
T-L"
8F8-OB/IT
1
85
1011
121
534
LBO
8' O"
9' 4'
Or-IB/2T
I
#5
2
#5
152
591
512
L90
T-0'
10'-L'
are-IS/2T
1
#5
2
#5
443
530
401
L90B
9'-0'
10'-6'
BFIL-IB/2T
ONE
1
#5
2
#5
1533
1183
401
LI00
10'-O'
ll'-4'
8F8-IB/2T
I
#5
2
85
582
494
452
LIOOB
10'-0"
II'-4'
BPIL-11I
ONE
1
#5
2
U5
13LL
1028
452
L120
12'-0'
13'-4"
8FB-IB/2T
1
#5
2
#5
411
428
324
L120B
12'-0'
13'-4"
8FIL-IB/2T
ONE
1
#5
2
#5
10-15
'110
324
L140
14'-0'
15'-4"
8FIL-IB/2T
ONE
I
U6
2
#5
1250
L09
259
LILo
IL'-O'
IT-4"
8F8-IB/2T
I
#5
2
#5
Soo
192
M4
LILOB
W-0"
IT-4"
BPIL-IB/2T
ONE
1
#5
2
#5
960
60o
M4
- ALL LINTELS SHALL BE MADE BY CAST-CRETE.
- LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD REQ.
REQUIREMENTS
- LINTELS OVER 14'-0" LONG ARE TO BE PRESTRESSED.
H
N
N
� X
� o
r
all
N
H�oa
a
a
�t N N
U
N� p�
E _ co
174
r
Q
�c
0
Q N
0 op
N
U
.n
v
to
block filled with concrete Vanes -see Ian All drgwal to a installed per FBC R102.3.1
riA (2) #1 b t t d p T and shell eet all ertainin ASTM codes
9\\",WE1E1E1,M1r
1EN
1-
IWas
s
et7a roofing attached to plilwood deck using #9 x 1.5"
IN
Mal
I
�i�l■I■lil■lil����i��
rto lintels above
or&ver a #5 bar Vert. w/ m Mortar to be Type "M' ont proportioned bar FBC RL01.1 ETA 20
30" overlap and Mort pants shall comply with FBC RLOl.2.l.
thicken edge to B"xB' P Provide ur-O-Rock at all wet areas (ex. showers, tubs etc...)
with concrete and at each filled cell
one #5 bar continuous
BEYOND Fill call wi h concrete and ROOF FLAN
Rear Patio/Slab to (D #5 bar wart. (typicaU.
be flush with bottom of Max. spaci g shall not exceed
48" unless otherwise noted
sliding door recess.
W°� see found i°^ plan notes far - OVERHANGS AT 1'-0" UNLESS OTHERWISE NOTED ON THIS SHEET
Top of Tooter Base spacing at openings
IL" below finished floor - ROOF PITCH AT 4:12 UNLESS OTHERWISE NOTED ON THIS SHEET
6. Step per foundation plan 4" conic etc slab with fibermesh OR
L"A' #10/ WWM on to mil Visqueen over — TRUSS SHOP DRAWINGS TO BE PROVIDED BY MANUFACTURER
Slope per foundation plan clean c pacted termite (treated fill — ANY CHANGES TO THIS PLAN SHALL BE SUBMITTED TO T H E
:::>::.,�.:-:-:•:::,...;; �:- <�;�:_:.�.;..:_....,:>.::.,,,....,.:::.,:.:. .._ _ _ RIOR TO STARTING CONSTRUCTION _ _ _ __ _ _ ARCHITECT FOR APPROVAL IN WRITING P
_ — II-1111—III-1 1111=(III-1111=(III=1111 I=1111 �IIII i ,(III— - ALL TRUSS TO TRUSS CONNECTIONS BY
(III-(III-111 (III(III(III(III=(III=(III—(III III ��I ,III TRUSS MANUFACTURER
—(III=(III=(III I II�III�II , , I1 1111 (III 1111 ��I�III 1=1 TTCHITECT TO CO CONSTRUCTION REVIEW FOR LAYOUT AND PRIORNGS P FT VERIFI
CATION
ICATION
-1�11„"IIIII„ Il� n11-1111 1111 Tgpical Section at Fr rt Forch - CONTRACTOR TO PROVIDE FOR FORM BOARD SURVEY AND TO PROVIDE
" = " FORM BOARD SURVEY TO TRUSS COMPANY UJRIOR TO TRUSS CONSTRUCTION
Braden t Braden AIA, PFADate Drawn: Revisions: Sheet Comm #
A chitects - Planners ynne Building Corp.Corp. 5-2'4-18
11 S.E. Coconut Avenue T H E STERLING REAR Drawn by: REVIEWED FOR
I : (112) 281-8258 PORCH C.C.U. CODE COMPLIANCE 1�-301
1= x : (112) 281-8283 RIGHT B
E- ail: bradenaia9comcast.net Spanish Lakes Checked by: ST. LUCIE COUNTY
Stuart L 3"4994 UAAC000032 St. Lucie County Florida Ld.M.B. 0OCC OF 5
PANEL
"A„
Poles
BR
Load I
Wire
Description
circ#
circ#
Description
Wire
Load
BR
Pdes
2
40
A/C comp
1
2
AHU
#10
3.5 kw
30
2
3
4
2
30
4kw#12
40 gal. water HTR
5
4
Range
#6
12.0 kw
50
2
l
a
1
20
Pump
9
10
Dr er
#10
5.0 Its
30
2
II
12
1
20
1.5 kw
#12
13
14
Dishwasher
*12
1.2 kw
20
1
1
20
1.5 kw
#12
Microwave
15
I6
Refrigerator
#12
1.2 kw
20
1
1
20
1.6 kw
#12
Kitchen S.A.C.
Il
I8
Recepts
#12
-
20
1
I
20
1.5 kw
#12
Kitchen S.A.C.
19
20
Reeepts
#12
20
1
1
20
1.2 kw
#12
Clothes Washer
21
22
Recepts
#12
20
1
1
20
0.81 ke
212
Garage Dow Opener
23
24
Recepts
#12
20
1
1
20
1.4 kw
#12
25
21,
Recepts
#12
20
1
1
20
1.92 Its
#12
21
28
Recepts
#12
20
1
1
20
#12
General Lighting
24
30
Recepts
#12
20
1
1
20
#12
General Lighting
31
32
Recepts
#12
20
1
1
20
#12
General Lighting
33
34
Exterior GFCI
#12
20
1
1
20
#12
General Lighting
35
%
Bathroom GFI
#12
20
I
f
20
#12
smoke Detectors
3-1
30General
Lighting
#12
20
1
I
20
#12
Bathroom GIN
39
40
General Lighting
#12
20
1
spare
41
42
s are
PANEL "A" LOAD CALCULATION SHEET
Load Description
Qty.
Watts
Total(Watts)
General Lighting .(3. watts sq. ft:) . . .. ......... ..... ....
Small, Appliance, Circuit(s),,, ,,,,,,,,,,,,,,,,,, ,,,,,,,,,,,
,Range...... .. ................ .................. ............
.Refrigerator..................................................
Microwa......... . ,
......ve
...........................................
Dish .Washer ...................................................
Clothes, .Washer ...............................................
Clothes,.Dryer.......................... ......................
Heater
...Water..............................................................
Water. Pump ............. . ....................................
Garage. Door .Opener ........................................
1135
3
5,205
2
1,500
3.000
1
12,000
12,000
1
1.200
1,200
1500
1
1500
1
1,200
1,200
1200
1
1200
1
5,000
5.000
1
4 500
41500
1
1,800
1.800
1
810
810
Total Watts
3-1,415
First 10000 Watts e100%
1
10,000
10.000
Remainder 21.415 e40%
1
O
10.96L.
Electric Heat or A/C 10,000 e65%
1
10,000
10,000
Calculated Load
Watts
30.9LL
Voltage
240
Calculated Wattage Divided bg Voltage = Total Amps 129.03
Panel Size Required = 150 Amps
Electric,al S mbol Leend
S
Single Pole Switch
®
Recessed Can Light
S3
Double Pole Switch
®
Eyeball Recessed
PB
Push Button switch
Exhaust Fan
Duplex Outlet
Gelling Mounted Light
Special Receptacle
0-
Wall Mounted Light
F
Waterproofgroup fault circuit
terrupter
w
Light with Pull Chain (attic)
®
Floor Duplex Outlet
©
Computer Connection Jack
0
Carbon Monoxide Detector
412
Flood Light
TU
Thermostat
m
Electrical Panel
®
Central Vac
g
Electrical Meter
®
Smoke Detector
Ceding fan
©
Television Jack
Telephone Jack
A sc
A/C Disconnect
®
I x 4 Florescent Light
®
2 x 4 Florescent Light
saiaz
speaker Hook -Up
El
Intercom
= JUNCTION BOX TO SUPPORT A FAN
tit = THERMOSTAT LOCATION
B/A = BALANCED AIR
Electric Notes:
I. Use copper wire only, no aluminum.
2. Provide and wire all required smoke detectors.
3. Contractor to verify location of electrical
service and provider.
4. ALL paddle fans shall be on a rheostat.
F. ALL bath and kitchen receptacles to be GFI protected.
6. ALL exterior outlets to be WP/GFI protected.
-1. Recessed cans to be installed per NFPA requirements.
S. AFCI receptacles are required in all rooms except
Kitchen, Bathrooms, and Garage.
9. A/C Return Air Balance Must comply w/ FBC RM1602
10. A/C Refri erant lines that are run thru slabs must be
sleeved in AVC
11. ALL A/C Equipment shall comply with energy calculation
12. All work shall be performed bg a licensed electrical
contractor, the completed system shall be fulig operative.
13. Contractor shall pay for all fees, permits, testing, and
inspections including blower testing where required.
14. All work shall be coordinated with other trades to avoid
interference with the progress of construction.
15. All required insurance shall be provided for protection
against the public liability and property damage for the
duration of the work.
16. Contractor shall guarantee all materials and workmanship
free of defects for a period of not less than two years from
the date of acceptance or certificate of occupancg, or one
gear from closing sale of house.
Correction of defects shall be completed without additional
charge and shall include replacements or repair of any
other phase of installation that may have been damaged.
Opt. PATIO/SLAB
149 CFM
loxlox6
Covered Porch
M STE
B DRO M
GkEAT
1�y00M
144 CFm
I
IOx10xL
12x12xIO
Center Reglstaa��rra B/A
208 CFM on ceiling ►6n 208 CFM
IOxlOxl OxlOx7 s!� e
12x1&dO
l2"
DINING
ROOM
H.B.
Vent _ti1rU--- _ _- 18x44�x4/
Soffit F3ATM
144 CFM
IOx6x6
SECOND
BEDROOM
12x12x8 I i
B/A il-
if
COVERED
PORCH
MECH4NICAL LAYOUT
scnLe. 1/9, - r-o,.
11. It is not the intent of these plans to show everg minor detail
of construction. The contractor shall furnish and install
all items for a complete electrical system and provide all
the requirements necessary for the equipment to be placed in
proper working order.
18. All work shall be done in accordance with the N.E.C. and
shall comply with all local codes and ordinances, and shall
meet all standard requirements of the local electric utility
and telephone company.
19. The electrical system shall be completely and effectively
grounded as required bg the latest edition of the N.E.C.
20. All material shall be new and shall bear underwriters'
labels where applicable.
21. All equipment and panel sizes shall be verified before
ordering. The contractor shall provide circuit routings to
suit the Job conditions.
22. Furnish and install all fixtures as called for on the plans
or as selected bg others.
23. All raceways and pipes placed in or through any concrete
slab shall be spaced a minimum of three diameters of the
largest conduit or pipe from any other service.
24. All exposed wire below 9'-1" shall be installed in metal EMT
conduit.
25. Dryer Vents to be installed per FBC RM1502
( MM
22" x 54"
Attic Access
with light I
G AR,AG
r-------------
I
I
I
I
I
#2/0 Aluminum feed
1'h" Conduit -�
2"PVC (PIP
2" rigid service FPL
, S1
150 Amp
Panel
A/C due.
wire
r in slab
ELECTRICAL, RISER
- Contractor shall use AL-CU anding lugs_ NTS
- Contractor shall torque. lugs I W..
prior to
-- Vent-t# f:I
Soffit
eter
H.B.
Exhaust Duct
Thru Soffit -
Wire For
Front Post
Light
Exhaust Duct
Thru Soffit
4" Exhaust
Duct Thru
Wail
Install oulet
under disc.
L shown for
clarity
ELECTRICAL PLAN
6'-3"
017-,Post Light with
I Photo cell
SCALE: 1 /4" = I'-011
c
Total Attic Space = 2124 sq. ft.
Venting Ratio 1/150 = 14,16 sq. ft. required
Provide A Continuous Vented Soffit
Braden It Braden AI,A, FA nne BuildingCOr Date Drawn Revisions Sheet Comm #
Airhitects - Planners -� p' 5-24-18 REVIEWED FOR
Z S.E. Coconut Avenue T H S �' R L I REAR Drawn b: CODE COMPLIANCE
T I : (112) 281-8258 PORCH g 1�-301
F (712) 281-8283 RIGHT C.C.U. ST. LUCIE COUNTY
tB E-m : bradenaia0comcast.net Spanish Lakes Checked by: BOCC j
R fiiArr_ 11,4019G #AAt^-000 12 St. Lucie County Florida D.R.B. OF 5
A=LIFE SAFETY WARNING
This symbol identifies Life Safety Warnings that should be read
given special attention by all persons installing trusses.
ASTENED TOGETHER PER ENGINEERING
BEFORE SETTING. REFER TO
ENGINEERING DRAWING TO DETERMINE
Ai IF MULTIPLE PLY.
Carrying Girder
For Truss to Truss
TNalls
Connections see
hanger/connectorbe as
de tabs oschedule in engineeringe nails.
package.
Carried Truss
SEAT PLATES BY CHAMBERS
upset=1/4" heel=315/16"
PLUMB CUT END
2 x 4 Top Chord
WALL HEIGHT 8'
END DETAIL: TYPICAL VAULT
upset=1/4" heel=3 15/16"
PLUMB CUT END
2 x 4 Top Chord
WALL HEIGHT 8'
TYPICAL END DETAIL
INDICATES LOAD BEARING
REQUIRED BY TRUSSES
SUPPLIED BY BUILDER
AT A HEIGHT OF 8'-0"
ABOVE FINISHED FLOOR
TRUSSES FOR THE FIRST MODEL SHOULD BE SHIPPED AND SUCCES FULLY SET BEFORE ANY MORE TRUSSES ARE BUILT FOR THAT MODEL
ARRANGE WITH CRANE OPERATOR IN ADVANCE OR A SPREADER BAR OF 18'- 24' IN LENGTH
Do not stand on trusses until they are braced per BCSI properly nailed to straps & hangers P, --- -
SPACING MOTE
ALL TRU55E5 ARE TC BE SET
AT 2'-O: ON GEt rER
EXCEPT AS NOTD
AI F2 HAIV f>LEFR NOTE
UNLESS NOTED ELSEWHERE ON THIS LAYOUT, THESE TRUSSES
ARE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR
ANY OTHER AIC REQUIREMENTS. THIS MAY BE IN CONFLICT
WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS.
CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR.
All load bea ing walls, headers,
beams & lint Is must be in place
at indicated ight before trusses
ar installed.
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
14' 22' 22' 14'
I I I I I I
�y®I©IMIMI®��1��//I®IMI�®/�/�Iy®I�MI/MI�®®I�Mimi
IWit111i/��I/H//%17�I
r//OAI
//
ea,I
%/Ia/ul
•��-�P1IN
Said
I
IPA
IN
I WOWS,
I NN
PAP
I
1,01
INVERTED%rWEBS
e.■
e• .•. .• •'
Iy
�1
i
—
i
,_
j
° •
••/II�1�I�1�11�%II�I�11■�I�I�I�I�I\
r
: -
��
r
_
®R
I®
r/�i
NO
II%/////.IWl421powolI
IMIMIMIMIMIMIMIMIMI■BI
..I�I�I�I�I®I�
I I I I I
15'-10" 5'4- T-4" 11'-6"
GARAGE LEFT
Mimi=
111111i\\\\\�I��
INVERTED'V" WEBS AT CENTER
W/9' B.C. PANNEL. LOAD W/ (2)
50# POINT LOADS PER TRUSS FOR A/H/U
v
aoa�a_
pal
®I�I�I�I�I�I�I■Blf�
iNXWXN
\�NNi\\NIIk
011
SIEMENS
!Vb
I
I
I
I
I
I
I
01
mg
ll,
I.\N Al l
A5
A5
A5
A5
A5
A5
,
ATA
ATA
ATA
ATA
ATA
ATA
ATA
ATB
ATC
BHA
d
Fn
ABRICATION AGREEMENT
USSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED 8 RETURNED
rops
legal description of the property where the busses will be Installed IS:
underslgnad acknowledges end agrees:
h hlaeee wll be made (his(use placement dlegrem layout,
h is the sole euthoflry for detelminingsuccesfultabdcallon oftheWest•
NI dlmensfone In this layout have beenvedkedby thundesignedUnless written notice Isprovided by certiaed mall to ChambersTNas within ten0 of delivery the untlerslgned agrees that no backcheryes will ba allowad..ln theawrfltan notice la /u 01 Chambers Trues shall havethree(3)bu rasa days in which
in re I
re re uI
e Pa red or
9 to sub
aUM
eoN
etru
exec
et C
hamb
a ere o' ��((Th underel nad ti8n.Dean y ls to Job sit" I Is viebuyers�re pone b ty to meka theeJobs a aulteble for
ry, Chambers Tlusa has the sole authority todetenolne the suitability of the Jab all,ran of the Job site for dakvery, Chambers 7ruse willbeeponelbls for dump tlellvery only,
soauuym le reeponelbls for addlUonel delhrery expenses U Chambers Truss has to redeliver
Ie lob eke Is not hemrepafor delivery or buyerIsnot prepared for delvery of truaaear le reeponelbls to Chambers Trues for towing coats due to she conditions S. Price as shown Iq paragraph 7 below Is Subject to change merry changes are. made In
this, layout A j per hour fee for revlslona may be charged by Chambers Ttusa,
. 7. This Is a PURCHASE ORDER to Chambers, Truea of the sum agreed to, or If na;
agreement a reasonable price, Invoice will be made on delivery and paid within terms of n 4L
on delivery. Invoice may be made at Scheduled data of. delivery If buyer cannot accepi
delivery of fabricated busses. The undersigned agrees to pay Chambers, TNss reasonable
attomeya fee for collections In event of Payment not timely made. 1-1/2%{
charge wI0 be added for all sums not paid wlthln termsservJce
per month II
• S. Signature or Initials anywhere on this sheet mnstliutes agreement to all terms herein.
w
9, In consideration of Chambers Tmas extending a for ails material the undersigned
unndttlonalty guarantees payment when due Of arry and all Indebtedness owed to
Chambers Truss by any entity receiving material and the undersigned agrees to pay such
Indebtedness Including •homey$ fees, If default In payment for material be made by the
rediclent.-
10. In the event of any litigation concerning this agreement, the Items furnished hereunder i I
or payments referred to herein, the, parties Ogres that the sole venue for any such action will
be Saint idols County, Florida.
11. Design reaponslbllNlea are par'Nationel Standard And RecOmmended-Guidelines On
Responsibiatlas For Construction Using Metal Plate
ANSI/TPIANTCA4-2002•- Connected Wood Trusses
DATED .
SIGNED
FOR -'--
TITLE_^ � ..... .
Aspreaderbarmaybe"a"per"ecsi 1-or4op,aysfrtl7dellvery
ge,
Multiple ply trusass must be fastened together peng
before they are set, failure to do so can result In re.
Temporary and permanent bracing are required anlife
and property and Is the responsibility of the tru
'Study the contents of the Information packet Includery
before setting trusses,
Tmnw mustbeaetaW braced Pi*mign io RwentkimyS
Trusses must be set plumb and square
Do not set bunks or stack of plywood, roofing material or any
other co'ndentrated loads on trusses, this can cause collapse.
DO NOT SET TRUSSES USING THIS LAYOUT
USE LAYOUT DELIVERED WITH TRUSSES TO SET TRUSSES
01 ua oleander Avenue
Fort Plercej Florida 34982-6423
800.551-5932
Fort Pierce 772.485-2012 Fax 771 465-8711
Vero Beach 772�568-2012 p Stuart f�'r7�72-2863302
shop drawinga .I
approval is NOT a
double check" of the contractor.
The contractor shall remain responsible
for checking field measurements and
other construction criteria. Architect's
approval covers general roof shape,
review of truss strapping, an loading on
structure from gravity an pli loads and
their respec ' oC dns.
Approved Bv:
Daly
92.0/93.2 MITEK 4.2 _
DESIGN CRITERIA A.A.
County SAINT LUCIE
Building Department ST LUCIE COUNTY
Wind Design Criteria ASCE 7-2010
Wind Design Method MWFRS/C-C hybrid Wind ASCE 7-10
Roofing Material Shingle or Shake
Loading in PSF Roof R.D.L.
0 � I Top Chord Live 20
N , Top Chord Dead 7 4.2
I o I Bottom Chord Live 10 Non -Concurrent
Bottom Chord Dead 10 3
o TOTAL Load 37 7.2
Duration Factor 1.25
w d
2 ' 3 Wind Speed 165mph
y
Top Chord C.B. Sheeting by builder.
V Bottom Chord C.B. Sheeting by builder.
LA Highest Mean Height 12'-0"
v ~� Building Type ENCLOSED
Building Category II:Non Restrictive
Exposure Category C
Barrier Island No
Conforms to FBC 2017
r[. U.L.=rCe3iramlrlQ used Load G.B.=GontinuouS Bracin
Verify DESIGN CRITERIA shown above with the
building department and your engineer.
Design Criteria is the responsibility of the
Building Desi ner and/or Engineer of Record.
Chambers Truss Inc. Drawing Name: M11412
w Scale: 1 /4 = 1'
73 total trusses, 18 different trusses.
MI 4: RLC ACAD: RLC Reviewed By:
Date:11/14/16 Revised:10/23/18
v J FOR
1V-8" y T-4" y\ 54" 15'-10" a WYNNE DEVELOPMENT CORP
—REVIEFOR 5 DESCRIPTION:
CCOMPLIANCE
GARAGE RIGHT SOLUCIE OUNTY ` STERLING
BOCC PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE
18 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT M 11412 7& //0
10 J/s
AL=LIFE SAFETY WARNING
This symbol identifies Life Safety Warnings that should be read
given special attention by all persons installing trusses.
ASTENED TOGETHER PER ENGINEERIN
BEFORE SETTING. REFER TO
ENGINEERING DRAWING TO DETERMINE
A IF MULTIPLE PLY.
For Truss to Truss Carrying Girder
Connections see
hanger/connectorTNadsbe as
e to so
schedule in engineeringe nails.e nails.
package.
Carried Truss
SEAT PLATES BY CHAMBERS
upset=1/4" heel=315/16"
PLUMB CUT END
2 x 4 Top Chord
WALL HEIGHT 8'
END DETAIL: TYPICAL VAULT
upset=1/4" heel=315/16"
PLUMB CUT END
2 x 4 Top Chord
WALL HEIGHT 8'
TYPICAL END DETAIL
INDICATES LOAD BEARING
REQUIRED BY TRUSSES
SUPPLIED BY BUILDER
AT A HEIGHT OF V-0"
ABOVE FINISHED FLOOR
TRUSSES FOR THE FIRST MODEL SHOULD BE SHIPPED AND SUCCES FULLY SET BEFORE ANY MORE TRUSSES ARE BUILT FOR THAT MODEL.
ARRANGE WITH CRANE OPERATOR IN ADVANCE OR A SPREADER BAR OF 18'- 24' IN LENGTH
Do not stand on trusses until they are braced per BCSI properly nailed to straps & hangers 7 -r i� 17N I
---
5PAGING NXE
ALL TRUSSES ARE TC BE SET
AT 2'-D: ON CENTER
EXCEPT AS NO
AIR ILiF= NpTE
UNLESS NOTED ELSEWH
ERE ON THI
S LAYOUT THE
SE
E TRUSSES
ARE NOT DESIG
NED FOR AIR HANDLERS IN THE ROOF OR FOR
ANY OTHER A/C REQUIREMENTS. THIS MAY BE IN CONFLICT
WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS.
CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR.
All load bea ing walls, headers,
beams & lint' Is must be in place
at indicated eight before trusses
A ar installed. Q
J2
J2
GRA✓'9e
0
r
"(-�P0
/qJ4I
J4
J6
J6
A
I
Al
1
A2
I
I 2.0 INT .00/ NT.
A3
I
I
A4
I
I
A5
I
A5
1
A5
I
_
A5
I
1
13'-8"
A5
1
AS
I
A5
ATA
ATA
ATA
ATA
INVERTED "V" WEBS AT CENTER
W/9' B.C. PANNEL. LOAD W/ (2)
50# POINT LOADS PER TRUSS FOR A/H/U
ATA
j
ATA
%
ATA
ATB
ATC
r;
BHA
zo
o
io
I
—T
I
I
--
✓e
J6
I
I
_
J6
J4
J4
J2
I N
-,
V
�
N
-,
cD
-�
aJ
�
W
�
to
�
m
�I
m
�
c0
�
Da
I �
O)
�
cD
I �
aJ
�
�
�
�
I
I I I I
15'-10" 64" 3'4"
GARAGE LEFT
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
NI=I=
is Ml
J2
J4
J6
It",,
INVERTED'V" WEBS AT CENTER
W/9' B.C. PANNEL. LOAD W/ (2)
50# POINT LOADS PER TRUSS FOR A/H/U
I
N=NIX\\`�i\\�01
&V \
ION
1p
=I�y��
A21
A5
A5
A5
A5
1
A21
A5
A5
A5
A5
1
AS
1
A5
1
1
A5
ATA
ATA
ATA
ATA
ATA
ATA
ATA
ATB
ATC
4✓I9 BHA
Ffobrkated
ABRICATION AGREEMENT
RU99E8 CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED a
The legal dearaiption of the property where the tmsaee will be Installed Is: RETURNED
e undersigned acknowledges end agrees:
1 Trusses will be made in etdct aaordance wth thle Was placement dlagram layout,
ich is the Bole autholfty for detennlning.successful fabrication o! the truass3. a.
2.All dlmenebns fa Mce
le layout have as
va es:d bcorthler y the undersigned.
sa written notice
ovided
ys ad
the under p ed ag esythat no backlgtt, w16 be allowed.. Truss i the avant
ch written notice Is ch
tumishad Chambere Trues shall have three will
business ..aye in which
be tl� nre Inre u e red Pa q or ro tubatl e ofh ec
tuJ W sees at Chambers
. The undersigned acknowledges receipt of'BCSI 1-03"summery heat by TPI a WTCA
, oeavery M to Job elte. It la the buyafs'responelblllty to make the Job she sutiable for
lvary. Chambers Truss hec the sole authority to detennlna the sultabllhy of the Job she or a
b Of the Job she far delivery. Chamber Truss will be responelble for dump dellvary only,
buyer la reaponalble for additional delHsrx expnses g Chemben Trues has to redeliver
auee job she la not prepared for dellvary or buyer le not prepared for dellvaryof Wesae,
er le raponsibis to Chemben Trues for towing soots due to she conditions
. Pike ea shown Iq paragraph 7 below la aub)ect to change If any chengee are, made Iri
I
ley Is
a 860 per hour tee for revisions may be charged by Chamber Truss.
: This is a PURCHASE ORDER to Chamben,Trss of the sum agreed to, or if na;
ement a reasonable price, Invoice will be made on delivery and paid within terms of net
elivery. Invoice may. be made at scheduled date of delivery If buyer cannot accept'
delivery of fabrksted Wsses. The underelpned agrees to pay ChamberTNeareasonable
ey's fee for collections In event of payment not timely made. 1.1/2 °h per month servJcee will be added for all sums not paid -within tens, Signature or Initials anywhere on this sheet oonstliutes agreement to all tense herein.
In consideration of Chamber Trust extending credit for this material the underlgned j
unconditionally guarantees payment when due of any and all Indebtedness owed to
'Chambers Truss by any entity receiving material and the undersigned agrees to pay such
Indebtedness Including attorneys fees, B default In payment for material be made by the
recipient. `•.
this
reement
or peymenfa referred to heHlelntthe, part eslagree that the sole the
venue kr any such action will
be saint lose county, Fbrido.
11. Dealpn responslWlAlea are per `National Standard And Rocommended0uldellnee On
Raeponslbltitles For CnsWctlon Ueing Metal Plate Connected Wood Trusses ANSI/TPIAM'CA4-20DP""� .
DATED
SIGNED
FOR TITLE
Aspeaderbarmaybe nlgt�ied per"BCSI Torto pevent itrzy& damage,
Multiple ply tru$
ses must be fastened together per engineering
before they are set; failure to do so can result In roof collapse.
Temporary and permanent bracing are required and can save Ilia
o
and property and Is the responalblllty of the truss erector.
Study the contents of the Information packet Included on delivery
before settlng trusses.
Trusses mu�beaeiarai braced perdeslgnio peverrtlnlurYBr dairtage.
Trusses must be set plumb and square
Do not"set bunks or stack of plywood, roofing material or any
Other coYicentrated loads on trusses, this can cause collapse.
DONOT SET TRUSSES USING THIS LAYOUT
USE L-------------
AYOUT DELIVERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
3105 Oleander Avenue
Fort Plerce; Florida 34982.8423
CUU-551-5932
Fort Pierce 772-455-2012 Fax 772-465.8711
Vero Beach 772.568-2012 Stuart 772-2863302 ' "ar-� eu."•!n. ursaaa$taPrl7h1-CSi= Ei:'1r It's rc-presen'tattve's
shop drawing approval is NOT a
"double check" of the contractor.
The contractor shall remain responsible
for checking field rneasurements and
other construction criteria. Architect's
approval covers general roof shape,
review of truss strapping, and loading on
structure from. gravity and uplift loads and
their respective ro at rats•
APProved B\,
Date:
92.0/93.2 MITEK 4.2 Braden E l3rade11 A. , -
DESIGN CRITERIA
County SAINT LUCIE
Building Department ST LUCIE COUNTY
in Design Criteria ASCE 7-2010
Wind Design Method MWFRS/C-C hybrid Wind ASCE 7-10
Roofing Material Shingle or Shake
Loading in PSF Roof R.D.L.
0 I Top Chord Live 20
a Top Chord Dead 7 4.2
10 o Bottom Chord Live 10 Non -Concurrent
r1( o I Bottom Chord Dead 10 3
o TOTAL Load 37 7.2
w Duration Factor 1.25
w m
Wind Speed 165mph
Top Chord C.B. Sheeting by builder.
V N Bottom Chord C.B. Sheeting by builder.
Highest Mean Height 12'-0"
~� Building Type ENCLOSED
Building Category II:Non Restrictive
Exposure Category C
Barrier Island No
Conforms to FBC 2017
R.U.L.=Restraining Dead Load C.B.=Continuous Bracin
Verify DESIGN CRITERIA shown above with the
building department and your engineer.
Design Criteria is the responsibility of the
Buildin Design— and/or En inter of Record.
Chambers Truss Inc. Drawing Name: M11412
W Scale: 1 /4 = 1'
73 total trusses, 18 different trusses.
MI 4: RLC ACAD: RLC Reviewed By:
Date:11/14/16 Revised:10/23/18
FOR
1 V-6" T-4" 514" 15'-10" REVIEWED FOR< WYNNE DEVELOPMENT CORP.
CODE COMPLIANNNN DESCRIPTION:
GARAGE RIGHT ST. LUCIE COON STERLING
SOCC PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE
18 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT M 11412 76 //0
10 j/ 5 1 an Ap\-