Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT �(tLtltlp�LL� Street: THE STERLING City, State, Zip: Permit Office: ST. LUCIE COUNTY vCAB��VVv�tlED FT. PIERCE, FL, Owner: \� 'N" �� Permit Number: Jurisdiction: T St LUCIeCOunty Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) _ 9. Wall Types sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1474.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1474.00 ft2 6. Conditioned floor area above grade (112) 1474 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R 112 7. Windows(141.3 sqft.) Description Area a. Sup: Attic, Rat: Attic, AH: Attic 6 300 a. U-Factor: Sgl, U=0.63 101.25 ft2 SHGC: SHGC=0.25 b. U-Factor. Sgl, U=0.65 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.239 14. Hot water systems 8. Floor Types (1473.5 sgft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft2 b. Conservation features EF: 0.970 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 48.34 PASS Total Baseline Loads: 48.53 1 hereby certify that the plans and specifications covered by Review of the plans and STgT� this calculation are in compliance with the Florida Energy specifications covered by this 04'i14E _s 0 Code. calculation indicates compliance "n with the Florida Energy Code. r+ nm(%•, -: .°'' PREPAR �1�-I� Before construction is completed DATE: this building will be inspected for y compliance with Section 553.908 ° I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. G'Op WE OWNER/�t�NT ��- BUILDING OFFICIAL: DATE: _ k9 Vk4 DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: WYNNE THE STERLING Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1474 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE STERLING Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE J Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1474 11792 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 329 2632 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 329 ft' ___ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft' ___ 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft' — 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 ft' ___ 0 1 0 5Slab-On-Grade Edge Insulatio BATH 5 ft 0 45 ft' — 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft' — 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft' 0 1 0 4117/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8SIab-On-Grade Edge Insulatio LAUNDRY Eft 0 42 ft2 0 1 0 9Slab-On-Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1553 ft2 246 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1474 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 329 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M.BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ftT 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE=>SW Exterior Concrete Block - Ext InS®EDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 2 SW=>NE Exterior Concrete Block - Ext InS®EDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.6 0 3 NW=>SE Exterior Concrete Block - Ext InS®EDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 5 NE=>SW Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 _ 6 NE=>SW Exterior Concrete Block - Ext In!HffDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.6 0 7 SE=>NW Exterior Concrete Block - Ext In93ffDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 S S=>N Exterior Concrete Block - Ext ImBIEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.6 0 9 SW=>NE Exterior Concrete Block - Ext InfiEDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 _12 SW=>NE Exterior Concrete Block -Ext lnsdlAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 13 NE=>SW Exterior Concrete Block - Ext In4GREAT/DIN1 4.1 26 0 8 0 208.0 ft2 0 0 0.6 0 14 NW=>SE Exterior Concrete Block - Ext Ins3REAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.6 0 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft2 0.23 0.6 0 4/17/2018 2:37 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW13 Metal 5 NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes 0.63 0.25 N 32.9 ft2 1 ft 0 in 1 ft 4 in 0.63 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in 0.63 0.25 N 24.0 ft2 6 ft 0 in 1 ft 4 in 0.63 0.25 N 37.5 ft2 1 ft 0 in 1 ft 4 in 0.65 0.21 N 40.0 ft2 8 ft 0 in 1 ft 4 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft2 315 ft2 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1375.7 75.53 142.04 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 DUCTS / — Supply — -- Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 300 ft' Attic 75 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablre Thermosta[[t:]]Y Ceiling Fans: Heating Jan [X] Feb Mar € Jun f[[ ]] Jul [[ ]] [X] Aug �X [ Sep (j L J ov [[([�]] Dec Venting I 1 Jan l J II 1 Feb X Mar Apr May lXl Jun [ Jul lXJ [ 1 Aug [ Sep lxl Oct ln1 Nov Dec Thermostat Schedule: HERS 2006.Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Coaling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/17/2018 2:37 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A. continuous air barrier shall be installed in the building envelope. - Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind ponino and w*rinc Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical1phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition, inspection of log walls shall be in accordance with the provisions of ICC400. 4/17/2018 2:38 PM EnergyGauge® USA- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. THE STERLING, FT. PIERCE, FL, 1. New construction or existing New (From Plans)- 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft' b. Frame - Wood, Adjacent R=11.0 192.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 2 d. N/A R= ft' 5. Is this a worst case? Yes 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=30.0 1474.00 ft' 6. Conditioned Floor area (ft� 1474 b. N/A R= ft' 7. Windows" Description Area c. N/A R= ft' a. U-Factor. Sgl, U=0.63 101.25 ft' 11. Ducts R ft' SHGC: SHGC=0.25 a. Sup: Attic, Ret: Attic, AH: Attic 6 300 b. U-Factor: Sgl, U=0.65 40.00 ft' SHGC: SHGC=0.21 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A fP a. Central Unit 34.8 SEERA5.00 SHGC: d. N/A ft' SHGC:: SHGC: 13. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.832 ft. a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.239 8. Floor Types Insulation Area 14. Hot water systems a. Slab -On -Grade Edge Insulation R=0.0 1473.60 ft' a. Electric Cap: 40 gallons b. N/A R= ft: EF: 0.97 c. N/A R= ft2 b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant feature_, Builder Signature: f-�� Date: �ayct` k c� Address of New Home: D C J��.V`a� City/FL Zip`S� 1 Vk-t 3"145� *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/1712018 2:37 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 VIA ��' - -�° wrighttsoft, Project Summary Entire House QUICK CALCS; INC. 317ST.LLUEu,L,FT.PIERCE,FL34946P9om:772466-6799Fe 772A666796 Emil: OUICKCALCS@A0L.00M -C) Date: aY. For. WYNNE DEVELOPMENT �JvBvftv THE STERLING, FT. PIERCE, FL (�� � . Lucie COD Olt Notes: �� � ��C� Design Information Weather. Winter Design Conditions Inside Outside b 70 °F Design TD 28 OF . - Heating Summary Structure 18188 Btuh Ducts 56 Central vent (0 cfm) 0 BBtuh (none) Humidification 0 Btuh Equmpmentload 23842 BBtuh Infiltration Fort Pierce, FL, US Summer Design Conditions Outsidedb 90 OF Insidedb 75 OF Design TO 15 OF Daily range L „ Relative humidity 50 o/n Moisture difference 61 gr4b Sensible Cooling Equipment Load Sizing Structure 17877 Btuh Ducts 8536 Btuh Central vent (0cfm) 0: Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier Equipment sensible load 0.95 25093 Btuh Method Simplified Latent Cooling Equipment.Load Sizing Construction quality Average Fireplaces 0 Structure 2958 Btuh Ducts 2319 Btuh Central vent (0 cfm) 0 Btuh Area01t Heatingg Coolingg (none) 1474 1474 Equipment latent load 5277 Btuh Volurime (fF) 12227 12227 i - Air changes/hour 0.45 0.23 Equipment Total Load (Sen+Lat) 30370 Btuh Equiv.AVF (cfm) 92 47 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Make Cartier Trade CARRIERAIR CONDITIONING Model 25HBC536KO30 AHRI ref 7914585 Efficiency 8.5 HSPF Heating input Heating output 34600 Btuh @47°F Temperature rise 27 OF Actual airflow 1160 cfm Airflowfactor 0.049 dm/Btuh Static pressure 0.50 in H2O Space thermostat Capacity balance point= 33 OF Backup: Input=7kW, Output= 23009 Btuh, 100 AFUE Cooling Equipment Summary Make Cartier Trade CARRIERAIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AHRI ref , 791458 Effictency 12.0 EER,15 SEER Sensiti 000ling 24360 Btuh Latent cooling 10440. Btuh Total cooling 34800 Btuh Actual airflow 1160 clin Airflowfactor 0.044 dmBtuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -v{+ wr�+lffe so• z9ts-sap_nUot:ta d+—.w. fSghFSUte®Uriuersa1201979.o.07 RSU08101 Page _oa &NWrieMortFNAGWYNNE-T}iESTERLWGnp Calc=MJ6 FrortDoorfaces:N F I wrlghtsoft- Right-J® Worksheet Job: Entire House Date: QUICK CALLS, INC. By". 317 ST. LUCIE M,Fr.. PIERCE, FL 34946 Phone:772-466-6799 FaK772-4666796 Email: OUICKCALCS@AOL.COM 1 Rgomn me, Entire House MASTER BEDROOM 2 6{wsadvsll 1552 It 52.0 It 3 Room height 8.3 It d 8.0 ft heakod 4 Room dimensions 1.0 x 329.0 ft 5 Roomarea 1473.5 K 329.0 ft Ty Construction U-value Or HTM Area (t ape (fe) Load number (BuhHttF) ° (BtUhmr) or perimeter (N (� Bub) or (to (Buh) Heat Cod Gross WS Heat Cool Gloss NrPi Heat Cool 6 1--G laA-40os 0.143 ne 4.00 255 _479. 442 ---1766 - _ 1124 - - 80 -- 60 - -320 204 lhclom - -- _1270 ne - -35.56 70.43 38 _ 0 i344 0 0 0 0 IW 13A-0ats 0.143 se 4.00 255 128 83 _ 331 _2662 210 _ 0 _ _ 0 0 _ 0 - H--la I—_ p 1A-dom 1270 e9 35.56 34.77 24 24 848 829 0 0 0 0 1 i 11 DO 0,390 se10.92 11.31 22 22 236 244 0 0 0 0 W _ 13A406 _ 0.143 s 4.00 _255 - 34 34 _ _ 136 86 0 0 - 0 _ 0 W LC 1344os 0.143 sw 4.00 255 360 353 _ _ 1414 899 _ 224 _ _ 224 _ 897 - 570 1Ac10m 1270 35.56 42.91 7 5 247 298 0 0 0 0 �41 _ _ 13A-4o6 0.143 _eN nw 4.00 2.55 290 217 867 551 112 79 318 _ 202 �—C 1AQom 1270 rw 35.56 4524 33 0 1162 1478 33 0 1162 1478 �C 4A5.2om . _ _ _ 0.770 rW . 21.56 . 27.54 41 . 0 880 1124 0 0 0 P 12C-Ow 0.091 255 128 192 192 489 _ _ 246 - 0 -- --0 0 -- -0 C - 30m 16A-d _ -22A-tpl 0.032 - - _ _ 0.90 2.32 _ _ 1474 - 1474 _ _1320 3419 329 329 _ 295 763 F- _- - 0.989 Z7.69 - 6.00 1474 156 4325 0 _ 329 _ 52-- ---1440 -1-- 0 6 c)AED elaason 784 680 Emelopelossligain 15W 13954 _ 4432 3897 12 a) Infiltration 2822 773 909 249 b) Roomtenfilation 0 0 0 0 13 Internal gains O—Pmts@ 230 5 1150 2 460 ApplianmaoBrer 20M 0 Subtotal Viries6to 13) 18188 17877 5341 4606 Lessel@&-mal load 0 0 0 0 Lesstransrer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18188 17877 5341 4606 15 Dudloads 31% 489% 5654 8536 31% 48%l 1660 2199 Total room load 23842 26413 7001 6805 Airrequired(dm) - 1160 1160 341 299 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wr�gb�LsvR- - 2019-Sep-1709:31:11 . A RigWStite@Lkiwrsal20l9l9.0.07RSW8101 Pagel ..oa rt.AWdgtBoRHUACIWYNNE-THESTERLINGnp Calc=MJ8 Front Doorra=N - wrightsoftY Right-M) Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN.. Fr. PIERCE, FL 34946 Phow:772-46G6799Fex772-466-6796 Email OUICKCALCS@AOL.COM 1 Roomname WIC MBATH 2 EVosedxell 0 It 8.0 It 3 Room height 8.0 It heatbod 8.0 It heatImol 4 Room dmensons 7.0 x 9.0 ft 7.0 x. 8.0 ft 5 Room arm 63.0 fl 56.0 IF Ty Constructon U-value or HTM Arm (W) Load Arm Load number (Btuhr-'q (BWh4t� a perimeter (M (Bluh) a perimeter (to (BWh) Heat Cod G. N,P/S Heat Cool Gross N/P/S Heat Cool 6 1 laA4= - 0.143 ne 4.00 Z55 0 0 - 0 0 0 0 0'_ -0 _!A-Oom__ _ . _- -_- 1270 m _ - 35.56 70A3 - 0 - _0 - 0 -b 0 0 =G IW .' 134-0as 0.143 m 4.00 255 0 0 0 _ 0 0 _0 0 _0 0 0 - I--G L—D_ 1A-clom 1270 era 351% 34.77 0 0. 0 0 0 0 0 0 11 11DO 0.390 10.92 11.31 0 0 0 0 0 0 0 W _ _ 134+iom _ 0.143 s_ 4.00 _ 255 _0 _ 0 0 _ 0 - 0 0 0 _ _ _0 0 W LG 134-0as 0.143 sv 4.00 2S5 0 0 _ 0 0 64 57.228 _ _ 145 1Aa1om _ 1270 w 35.56 42.91 0 0 0 0 7 5 247 2.98 13A-0&s _ 0.143 w _ 4.00 2.55 _ 0 0 0 _ 0- 0 0 0 _ _ 0 1Actom 1270 w 35.56 4524 0 0 0 0 0 0 0 0 4A5-2cm._ _.— --0.770 _w 21.56 2754 0. 0._ 0_ 0 o P 12C-Ow 0.091 - 255 128 _ 0 0 0 _ 0 _ _ 0 0 0_ _ _ 0 C_- 16A-30md - - _ 0.032 _ -_ _ 0.90 Z32 _ 63 63 _ 56 146 - _ - - 50 ___ 130 F 22A41 _ 0.989 - 2749 _ 0.00 63 0 0 - 0 _ _66 56 -56- '8 222 _ _ 0 6 c)AED exaason -2 - 225 Emelope loss/gain 56 145 747 798 12 a) Infiltration 0 0 140 38 b) Roomventlation 0 0 0 0 13 Internal gains Dmlpants@ 230 0 0 0 0 AppliarloesbtlxY 0 0 Subtedoinm61o13) 56 145 887 W6 Less 86MW load 0 0 0 0 L,asstranSer 0 0 0 0 Redistribution 0 0 0 0 14 Subtoal 56 145 887 836 15 Dudloads 31% 48% 18 69 31% 48% 276 399 Total room load 74 214 1162 1235 Airrequiied(dm) 4 9 57 54 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -FW mvLainsofe- 2019-Sep-170991:11 Right-Sutel-0 Universal 201919.0.07 RSU08101 page 2 ...oamertAWdgtboft WAMWYNNE-TI-DSTERLINGnp Calc=MJ8 From Ooarfares:N wrightsoft Right-lO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 SM LUCIE LN.,Fr.. PIERCE, FL 34946 PhDm:772-466.6799 Fax772466-6796 EmaiI:QUICKCALCS@AOL.COM 1 Room narne WTCHEN RATH 2 3 EPosedwall Room height 0 ft 8.0 It heatlmol 5.0 ft 8A ft heaticool 4 5 Roam dimensions Room area 1.0 x 1920 ft 192.0 ft- 9.0 x 5.0 It 45.0 fe Ty Construction number U-value (Muhme-T) Or HTM (BUM Area (fe) or perimeter (fl) Load (BWh). Area (ft') or perimeter (fl) Load (Btuh) Heat Cod Gross NAS Heat Cool Gross N/P/S Heat Cool 6 %EL— m4om 0.143 me 4.00 2.55 0 0 0 0 40- - - 40 - 166 - 102 G 1AIom___ — 13A-0o6 ,-.1270-ne 0.143 -35.56 4.00 70.43- 255 '-' 0-'" 0 0 0 _ 0 0 0 0 _ 0' 0- 0 0 _ .0 0 _ _0 0 11 I--u II----DD_ 1Actom 11DO 1270 0.390 so sa 35.56 10.92 34.77 11.31 0 0 0 0 0 0 0 0 0 0_ 0 0 0 0 0 0 W.- 1� 13A44om- _ _ 13A-4= _ _ 0.143 0.143 -5 sv _ 4.00 - 4.00 _ 255 255 0 0 0 0 _ 0 0 0 0 0-- 0 0 0 _ 0 0 _ _ 0 0 —G 1A-dom 1270 35.56 4291 0 0 0 0 0 0 0'_ 0 1t� I--G _ _ 13A4ocs 1A-dom Q143 1270 _sv dw rw 4.00 3556 _ 255 4524 _ 0 0 _ 0 0 _ 0 0 0 0 _ � 0' 0- _ _ 0 0 � �0 0 _ � 0 0 P C 4A5-2om_ 12C-Ow _ _ _ 164-30mtl . _ 0.770 Q091 _ 0.032 _mv _ - - ._ 21.56 255 0.90 -27.69 27.54 128 232 0 64 - 192 _ _ 0 64 _ 192 0 _ 163 -- - 172 _ 0 82 445 0 0 45 0 � -_- 0 45 0 _ - 0 -40 0 _- 0 _104 F 22MO _ 0.989 0.00 192 0 0 0 45 - - 5 - - 138 _ 0 6 c)AFD ec raian -Z7 -2 En,Mope losstgain 335 501 339 204 12 a). Infiltralion 0 0 87 24 b) 'RoomcenElatron 0 0 0 0 13 IMemal gains O=pants@ 230 0 0 0 0 AppliancesWw 2000 0 Subtotaloines6013) 335 2501 426 228 LesseiJemalload 0 0 0 0 Lessiart4er 0 0 01 0 14 RedistribOon Subotal 0 335 0 2501 0 426 0 228 15 Ductloads 31% 48°/a 104 1194 31% 4WA 133 109 Total morn load 439 3695 559 336 Air required (dm) 21 162 27 15 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 201&Sep-1709:31:11 RigWSuteS tkieersel201919.0.07 RSW8101 Page 3 ..o rtAWdglhoft WAMWYNNE-THESTERLINGjW Calc=MJB FmADoorfam&N wrightsoftY Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE M Fr. PIERCE, FL34946 PIorIe: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS®AOL.COM 1 Room lame BEDROOM2 ENTRY 322 ft 7.0 ft 3 R ighl t 8.0 ft heaV=l. 8.0 ft heavooal 4 Room dimensions 1.0 x 203.5 ft 1.0 x 55.0 It 5 Roomarea 2035 ft' 55.0 If Ty Conshudon U-value Or HTM Area (M Load Area (fe), Load number (Bk*OF-T) (BWhi* a perimeter (M (Bhfi) a Perimeter (fl) (B(uh) Heat Cod Gross NAS Heat Cool Gross NIPS Heat Cod 6 W! - _C 13A-4= 0.143 re 4.W 255 128 128 513 -0 -0 - - 0 0 1Ac1om __ __ 1270 m 35.56 70.43 --- . - `0 '- 0 0 _326 0 - 0 0 0 - 0 W ia"ots 0.143 se 4.00 2.55 80 56 225 143 48 26 106 _ 67 1Ac1om 1270 se 35.56 34.77 24 24 848 829 0 0 0 0 11 11DO 0.390 se 10.92 11.31 0 0 0 0 22 22 236 244 W - _ - WAOCS _ 0.143 _ a 4.00 _ 255 _ 34 34 136 86 0- 0 - ` 0 0 W L-C 134-4acs 1A-clom 0.143 sw 4.00 2.55 16 16 64 41 8 8 32 _ 20 tN I--r' 13A4= 1270 -0.143 sN w 35.56 4.00 42.91 2.55 0 _ 0 0 - 0 0 0 0 0 0 - 0 0 '0 0 ` 0 0 - - 0 1Ac1om 1270 w 35.56 4524 0 0 0 0 0 0 0 0 _ 4A5-2am - _ _ _ _ _ - -0.770 _ rnv . _ 21.56 _ 27.54 -- - 0 - -- - - ° _ 0. 0 0 0 0 -. 0 P _ 12C-0Ow _ 0.091 255 128 0 0 0 0 _ _ 72 183 - 92 C _ - _ 164-30md _ - - _ - -_ 0.032 _ - 0.90 232 _ 204 __ 204 _ 182 472 _72 55 _ 55 _ 49 - 128 F- _ _ 22A-41 _ _ _ 0.989 - 27.69 0.00 _ 204 32 _ _891 0 _ _55 _ _ _ - 7 - .194 - - - 0 6 c) AEC -=son -24 -6 EnvelopelosJgain 2859 1873 800 545 12 a) Infiltaton 564 154 122 34 b) RoomveMMon 0 0 0 0 13 Internal gains: Oovpants@ 230 1 236 0 0 Appliancesbftr 0 0 Subtohl Qines6t113) 3422 2257 922 579 Lesse)demalload 0 0 0 0 Lesstansfer 0 0 0 0 Recristribulion 0 0 0 0 14 Subblal 3422 2257 922 579 15 Dudloads 31% 481/a 1064 1078 31% 48% 287 276 Total mom load 1 1 4486 3335 1209 855 Air required (dim) 218 - 146 59 38 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrrap' a=r!- 2019-Sep-1709:31:11 lak Rigtt-SdteGUrim=1201919.0.07 RSW8101 Page 4 .-ow rb\Wnghlwft HVACrWYMNE-THESTERUNGnp Cale=MJ8 FrortDoorfaces: N wrightsoft, Right-J®Worksheet Job: Entire House Date: QUICK CALCS, INC. Br. 317 ST. LUCIE LN.,Fr.. PIERCE, FL 34946 Phpre: 772-466-6799 Fax772-466A796 Email: OUICKCALCS@AOL.COM 1 Roomnarne LAUNDRY GREATIDINING 2 Exposedvell 6.0 It 46.0 It 3 Room height &0 ft heaVmol 8.9 It heaftol 4 5 Room dimensions Raomarea 7.0 x 6.0 ft 420 ft' ID x 488D it 488D IF Ty Construmon U-value or HTM Area (� Load number (Bvhlft °*D: (BWhR� a Perim (M (�) orperi(to (Btuh) Heat Cad Grow NIPS Heat Cod Gross NIPS Heat Cod 6 h}J 13A4= Q143 W 4.00 255 0 0 0 0 231 _ .194 '775 _ . 493 1A-dom - --- - - — -1270 ne 35.66 70.43 _ - 0 0 '0 _ 0 _ 35 _ 0 1344 W 13A-4ors Q143 se 4.00 255 0 0 _ . 0 0 0 0 0 _2862 0 �1A-dom 1270 ce 35.56 34.77 0 0 0 0 0 0 0 0 11 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0- 0 0 _ W _ _ 13A-40s Q143 s 4.00 255 0 0 _ � _ _ __ 0 W LG 13A-0as _ Q143 wr 4.00 _ 2,55 _ 48 48 - 192 122 - 0 - - '0 - _ 0 _ -- 0 1Ao1om 1270 sv 35.56 42.91 0 0 0 0 0 0 0 13A-4da - 0.143 my 4.00 255 0 0 _ _0 0 0 '178 '137 549 _ 349 1Aclom 1270 my 3556 4524 0 0 0 0 0 0 0 0 _ 4A5-20m - _ _ 0.770 my 21.56 27.54 _ 0 _ 0 0 0 41 880 1124 P w 0.091 255 128 _ _ 56 56 143 _ 72 _ 0 _ .0— 0 _ 0 _ 0 C_ _12C-O _ 16M90md _ _ _ 0.032 _ - _ 0.90 2.32 _ 42 42 _ 38 97 488 - 488 __ _ 437 _ _ - F 22A-tol _ . - - _ _- 0.989 - -- - 27.69 0.00 - 42 6 _ 166 0 _ 488 46 - -- 1274 _1132 0 6 c)AEDexaadon -3 .56 Envelope low/gain 539 288 5259 5704 12 a) Infiltration 105 29 895 245 b) Roomtentlafion 0 0 0 0 13 Internal gains Covpants@ 230 0 0 2 460 Appliarlcesblier 0 0 Srlbbtel(lines6to13) 644 317 6154 6409 Lessextemalload 0 0 0 0 Lesstraratr 0 0 0 0 Redisbibution 0 0 0 0 14 Sublow 644 317 6154 6409 15 DUdloads 31% 46-A 200 151 31% 43% 1913 3060 Tohl room load 844 468 8067 8969 Airrequired(dm) 41 21 393 418 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrYat, �ra. - 2019-Sep-170911:11 a RiglFSdteO Lkiexrsd 201919.0.07 RS W8101 Page 5 ._o risAWngtbaftHVAQWYNNE-TFESTERLNGAp Calc=MJS FrortDoorfaces:N Duct System Summary Job: wrightsoft y ry Date: Entire House By. QUICK CALCS, INC. 317 ST. LUCIE UN., Fr. PIERCE, FL 34946 Phow:772-466-6799Fax772-46"796 Email: OUICKCALCS@AOLCOM r-roject Intormation For. WYNNE DEVELOPMENT THE STERLING, FT. PIERCE, FL Heating Cooling Extemal static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.284 in/100ft 0.284 in/100ft Actual air flow 1160 cfm 1160 ctm Total effective length (rEL) 176 ft Supply Branch Detail Table Name Design (13tuh) Htg (cfm) Clg (dm) Design FR Diam (n) H x W (In) Dud Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 559 27 15 0.376 4.0 Ox0 VIFx 18.1 115.0 st1 BEDROOM2 h 4486 218 146 0.374 6.0 Ox0 VIFx 18.6 115.0 st1 ENTRY h 1209 59 38 0.510 4.0 Ox0 VIFx 3.0 95.0 GREAT/DINING c 4735 196 208 0.318 7.0 Ox0 VIFx 22.4 135.0 st2 GREATIDIMNGB c 4735 196 208 0.307 7.0 Ox0 VIFx 28.1 135.0 st2 KITCHEN c 3695 21 162 0.375 7.0 Ox0 VIFx 18.3 115.0 st1 LAUNDRY h 844 41 21 0.366 6.0 Ox0 VIFx 21.6 115.0 st1 M.BATH h 1162 57 54 0.366 4.0 Ox0 VIFx 21.6 115.0 st1 MASTERBEDROONLA h 3501 170 149 0.297 6.0 Ox0 VIFx 33.1 135.6 s2 MASTERBEDROONLB h 3501 170 149 0.284 6.0 Ox0 VIFx 41.1 135.0 st2 is c 214 4 9 0,310 4.0 Ox0 VIFx 26.3 135.0 st2 Supply Trunk Detail Table Trunk Htg CIg Design Veloc Diam H x W Dud Name Type (cfm) (dm) FR (fpm) (in) (In) Material Trunk st2 PeakAVF 737 724 0.284 938 12.0 0 x 0 VinlFlx st1 stl PeakAVF 1101 1122 0.284 1050 14.0 0 x 0 VInIFIx "• wrightso:t- 2019-Sep-170931:11 Rig"titeOUriw=1201919.0.07RSW8101 Page 1 �A..oamerts\Wrigltwft FNACIWYNNE-TFESTERLWGnp CaIc=MJB FrortWorfacesN Return Branch Detail Table Name Grille Size (in) Htg (cfin) cIg (cfm) TEL M Design FR . Veloc (fpm) Diam (in) HxW (in) Saud/Joist Opening (in) Dud MaU Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 MFx wrightsoft' 2019Sep-170911:11 Pigtt-SLiteE)Uriwml20l9l9.O.O7RSWS101 -Page 2 �+� .-oomer&Wngrfsofl HVAaWYNNE-THE STERLINGnp Calc=MJS Frort Door faces: N