Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
FORM R405-2017 ,FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: D^EV GRAND CARLTON SITTING Builder ST SCAM Street: ZS � v.2- C� ck Permit Office:. LUICE OUNTYNNE httF1 City, State, Zip: Fr. PIERCE, FL, Permit Number: BYA Owner: Jurisdiction: p,, SQ I iicipQ)HntV Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1571.1 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1443.10 ft2 b. Frame - Wood, Adjacent R=11.0 128.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1646.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1646.00 ft2 6. Conditioned floor area above grade (ft2) 1646 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(138.8 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 325 a. U-Factor. Sgi, U=0.63 138.75 ft2 SHGC: SHGC=0.25 b. U-Factor. N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13, Heating systems kBtu/hr Efficiency d. U-Factor: WA ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.692 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1645.5 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1645.50 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits CF, Pstat Glass/Floor Area: 0.084 Total Proposed Modified Loads: 53.42 PASS Total Baseline Loads: 53.63 1 hereby certify that the plans and specifications covered by Review of the plans and ST1? this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. ti nm ,::;?'•°;:• °O, O� PREPARED BY: DATE: tdi=S�T Before construction is completed this building will be inspected for compliance with Section 553.908 - y I hereby certify that this building, as designed' ampliance Florida Statutes. !) yS with the Florida Code� CDD WE �O �Energy BUILDING OFFICIAL: DATE: \\`? DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 6/5/2019 5:01 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 'FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE DEV GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1646 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPEMNT Rotate Angle: 225 Street: Permit Office: ST. LUICE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.6 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1646 15472.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 252 2368.8 No 0 1 1 Yes Yes Yes 2 WIC 63 592.2 No 0 1 No Yes Yes 3 MASTER BATH 63 592.2 No 0 1 Yes Yes Yes 4 M. BATH 56 526.4 No 0 1 Yes Yes Yes 5 KITCHEN 192 1804.8 Yes 0 1 No Yes Yes 6 BATH 45 423 No 0 1 Yes Yes Yes 7 BEDROOM 2 204 1917.6 No 0 1 1 Yes Yes Yes 8 ENTRY 61 573 No 0 1 Yes Yes Yes 9 LAUNDRY 42 395 No 0 1 Yes Yes Yes 10 SITTING ROOM 200 1880 No 0 1 Yes Yes Yes 11 GREAT/DINING 468 4399 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 32 ft 0 252 ft' — 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft2 ___ 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 9 ft 0 63 ft2 — 0 1 0 4 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 W -_ 0 1 0 5 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 ft2 — 0 1 0 6 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft2 -_ 0 1 0 6/5/2019 5:01 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 'FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 7 Slab -On -Grade Edge Insulatio BEDROOM 2 31.2 ft 0 203.5 ft' ___ 0 1 0 8 Slab -On -Grade Edge Insulatio ENTRY 7 It 0 61 ft' 0 1 0 9 Slab -On -Grade Edge Insulatio LAUNDRY Eft 0 42 ft' ___ 0 1 0 10Slab-On-Grade Edge Insulatio SITTING ROOM 3011 0 200 ft' _ 0 1 0 11SIab-On-Grade Edge Insulatio GREATIDINING 25 ft 0 468 ft' ___ 0 1 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1735 ft' 274 ft' Light N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1646 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 252 ft' 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 63 ft' 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 5 Under Attic (Vented) KITCHEN 30 Blown 192 ft' 0.1 Wood 6 Under Attic (Vented) BATH 30 Blown 45 ft' 0.1 Wood 7 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft' 0.1 Wood 8 Under Attic (Vented) ENTRY 30 Blown 61 ft' 0.1 Wood 9 Under Attic (Vented) LAUNDRY 30 Blown 42 ft' 0.1 Wood 10 Under Attic (Vented) SITTING ROOM 30 Blown 200 ft' 0.1 Wood 11 Under Attic (Vented) GREAT/DINING 30 Blown 468 ft' 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE=>W Exterior Concrete Block - Ext Ins®EDROOM 4.1 18 0 9 5 169.5 ft' 0 0 0.6 0 2 NW=>S Exterior Concrete Block - Ext Ins®EDROOM 4.1 14 0 9 5 131.8 ft' 0 0 0.6 0 3 NE=>W Exterior Concrete Block - Ext InsMASTER BA 4.1 9 0 9 5 84.8 ft' 0 0 0.6 0 4 NE=>W Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 9 5 75.3 It' 0 0 0.6 0 5 SW=>E Exterior Concrete Block -Ext lnsul BATH 4.1 5 0 9 5 47.1 ft' 0 0 0.6 0 6 NE=>W Exterior Concrete Block - Ext InfiEDROOM 2 4.1 1 0 9 5 9.4 ft' 0 0 0.6 0 7 E=>NW Exterior Concrete Block - Ext InS EDROOM 2 4.1 4 3 9 5 40.0 ft' 0 0 0.6 0 8 SE=>N Exterior Concrete Block - Ext IndIEDROOM 2 4.1 10 0 9 5 94.2 ft' 0 0 0.6 0 6/5/2019 5:01 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 -FORM R406-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 9 SW=>E Exterior Concrete Block - Ext InfiffDROOM 2 4.1 16 0 9 5 150.7 ft' 0 0 0.6 0 10 NE=>W Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 9 5 9.4 ft' 0 0 0.6 0 11 SE=>N Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 9 5 56.5 ft' 0 0 0.6 0 12 NE=>W Exterior Concrete Block- Ext InsdIAUNDRY 4.1 6 0 9 5 56.5 ft' 0 0 0.6 0 13 SW=>E Exterior Concrete Block -Ext Ins91TTING RO 4.1 10 0 9 5 94.2 ft° 0 0 0.6 0 14 NW=>S Exterior Concrete Block - Ext InsSITTING RO 4.1 20 0 9 5 188.3 ftz 0 0 0.6 0 15 SW=>E Exterior Concrete Block- Ext lnsGREAT/DINT 4.1 25 0 9 5 235.4 ft' 0 0 0.6 0 16 N=>SW Garage Frame - Wood BEDROOM 2 11 16 8 128.0 ft' 0.23 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>N Wood ENTRY None .39 3 1 7 21.6 ft' 2 SW=>E Insulated SITTING RO None .39 3 7 21 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. _ / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>S 2 Metal Law-E Single Yes 0.63 0.25 N 32.9 ft' 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 NE=>W 4 Metal Low-E Single Yes 0.63 0.25 N 6.9 ft' 2 ft 0 in 1 ft 4 in None None 3 SE=>N 8 Metal Low-E Single Yes 0.63 0.25 N 24.0 ft' 6 It 0 in 1 ft 4 in None None 4 NW=>S 14 Metal Low-E Single Yes 0.63 0.25 N 37.5 ft° 2 ft 0 in 1 It 4 in None None 5 SW=>E 15 Metal Low-E Single Yes 0.63 0.25 N 37.5 ft' 2 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 320 ft' 320 ft' 16 It 8 It 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000299 1289.3 70.78 133.12 .1104 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 6/5/2019 5:01 PM EnergyGaugeS USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central UniU Split SEER: 15 34.8 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / — Supply -- — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 325 ft' Attic 95 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablfe Thermostar[t:,]Y C[reiling Fans: Heating Jan Feb fx]j' Mov ar [ � Mayf[{ Jun ]] Jul [[ ]] [X] Aug [[ ]] (] txJ Sep L Nov[rX'][X,] Dec Venting (1 Jan [ 1 Feb L l l l [X) Mar lxl Apr [ May Jun [ Jul lXl [[ ]) Aug [[ ]) Sep lxl Occtt [X] Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft' 0 ft 0.3 BEDROOM Default(8 lbs/sq.ft. ft' ft 0.3 WIC Default(8 lbs/sq.ft. ft' ft 0.3 MASTER BATH Default(8 lbs/sq.ft. ft' ft 0.3 M. BATH Default(8 lbs/sq.ft. ft' ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft' ft 0.3 BATH Default(8 lbs/sq.ft. fN ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' ft 0.3 ENTRY Default(8 lbs/sq.ft. ft' ft 0.3 LAUNDRY Default(8 lbs/sq.ft. ft' ft 0.3 SITTING ROOM Default(8 lbs/s.ft. ftT _ It 0.3 GREAT/DINING 6/5/2019 5:01 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2617 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE DEV GRAND CARLTON SITTING Builder Name: WYNNE DEVELOPEMNT Street: Permit Office: ST. LUICE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. Y U Owner. Jurisdiction: w x Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks orjoints in the air barrier shall be sealed. Ceilinglattic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped wiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wirong Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition, inspection of log walls shall be in accordancewith the provisions of ICC-400. 6/5/2019 5:01 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1646 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.630 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 c) Area 7c. 138.8 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 10A1. 10A2. 4.1 14. Heating system: Capacity 34.8 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.95 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF f) Heat recovery unit HeatRecO/a g) Other 10131. 11.0 10132. 16. HVAC credits claimed (Performance Method) a) Ceiling fans Yes 11a. 30.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1 certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature:_ _ Date: Address of New Home b City/FL Zip: FT n co C ri�� �o/aCh � �552 6/5/2019 5:04:42 PM EnergyGaugeO USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Project Summary �G — o Q� wrightsoft Entire House Data: QUICK CALCS, INC. SCAN N BY 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Phcre: 772-466-6799 Fas772466-6796 Emil: OUICKCALCS@AOL.COM C.c, I rOC1��nr�Pl�y� For. WYNNE DEVELOPMENT WN TRACTOR CC GRAND CARLTON WITH SITTING, FT. PIERCE, FL Notes: l<;,, � REVIEWED FUh Weather. Fort Pierce, FL, US Winter Design Conditions CODE COMPLIANCE bucc If I Summer Design Conditions Outside db 42 OF Outside db 90 OF Insidedb 70 OF Inside db 75 OF Design TO 28 OF Design TO 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18198 Btuh Structure 17140 Btuh Ducts 5997 Btuh Ducts 9058 Btuh Central vent (0 cfrn) 0 Btuh Central vent (0 cTm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipmentload 24194 Btuh Use manufacturer's data n Ratelswnggmultipptier Equipmeriisensibleload 0.95 24888 Btuh Infiltration Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3150 Btuh Duds 2473 Btuh Central vent (0 cfm) 0 Btuh Heatingg Cool' (none) Area 1646 1646 Equipment latent load 5624 Btuh Volume ft) 14006 14006 Airchanges/hour 0.38 Equiv.A 0.20 Equipment Total Load (Sen+Lat) 30511 Btuh (cfm) 89 47 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIERAIR CONDITIONING Trade CARRIERAIR CONDITIONING Model 25HBC536A'030 Cond 26HBC536KO30 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER,15 SEER Heating Input Sensible cooling 24360 Btuh Heating output 34600 Btuh@47°F Latentcooling 10440 Btuh Temperature rise 27 OF Total cooling 34800 Btuh Actual airflow 1160 cfm Actual airflow 1160 cfiT1 Airflowfactor 0.048 cfm/Btuh Airflowfactor 0.044 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.82 Capacity balance point=33 OF Backup: Input=7kW, Output= 23009 Btuh, 100 AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. /- .,yp ti�pft• 2019-Sep-1710:41:48 w—+—.—, Rigrl-SdtIQUi..1201919.0.07RSU08101 Pagel _ClW%NE-THE GRAND CARLTON-WnHSrMNG ROOMxW Calc=14I8 IrmriDoorfaoss: N + wrightsoft- Right-M) Worksheet Job: Entire House Date: QUICK CALCS, INC. 6y. 317 ST. LUCIE LN,FF. PIERCE, FL 34946 Phone: 772486-6799 Fax772-466£796 Email: OUICKCALCS@AOL.COM 1 Room name EntireHouse MASTER BEDROOM 2 Expased%dl 1532It 41.0It 3 Room height 8.5 It d 8.0 1t heallmbl 4 Room dimensions 1.0 x 315.0 R 5 Roomarea 16455 fe 315.0 fl Ty Con5ruction U-value Or HTM Area (M Load Area (fix) Load number (BIuhAtLq (BNfMBj a perimeter (to (Btuh) a perimeter (fl) (BWh) Heat Cod Gross N/PIS Heat Cool Gros N/P/S Heat Cool 6 lQ! 134-0as- - - 0.143 ne 4.00 2.55 493 434 1739 1105 0 0- 0 _0 1Aclom 1270 n , 35.56 70.43 38 0 1344 2662 0 0 0 0 11D0 _ _ _ _ _0390 W. -se 10.92 ..11.31 _ 21 21 238 0 0-- 0 0 134-0a5 0.143 _ 4.00 2.55 _ _ 128 _ 83. _ __229 331 - _ 210 - - - - 0 - 0 -�0 -'- "0 11 IActom 1270 sa 35.56 34.77 24 24 848 829 0 0 0 0 �D 11D0 - 0.390 10.92 1131 22 22 236 244 0 0 0 0 W� _ 13A-Acts. . . _ _ _0.143 _re 5 _ _ 4.00 _ ... 2.55 34 _ 34 86 0 _ _ 0 W 13A-4as 1Actom 0.143 sw 4.00 255 _ 344 337 _. _.136 1350 858 _.. 216 _._ _.0 216 _ _ _0 865 _ _ __. 550 IW 13A-4cs-- - - 1270 --0.143 w my _35.56 4.00 42.91 255 _ 7 272 5 - 202 247 --807 298 -513 _ 0' 112 _ _ 0 79 _ _ 0 318 0 202 H---li IA-clom 1270 mY 35.56 4524 33 0 - 1162 1478 33 0 1162 1478 4A5-20m__. _ _ ._ _ _ _ 0.770 _w 21.56 _ __.20.11 _ ---38 .0 _ 815. _ _ 760, _ .. _0 . _ . _ 0 P 12c-ow DD91 - 255 128 200 2D0 510 257 0 _0 0 __0 0 _ 0 _C _ _ _ 184-30md_ _ _ - _ __ ___0.032 _ -. .0.90 _ _ 2.32 1646 - 1648 _ _ 3818 _ 315 ---315 _ _ 282 __. 731 F_ _. 22A-Q�I, _ _ _ 0.989 - 27.69 0.00 - _ 1646 _ 153 .- _ _1474 4241 _ 0 _ _ 315 41 _ _ 1135 _ _ 0 a c)AED emersion 634 533 Envelope losstgain 15468 13990 3762 3494 12 a) 9rfift!ion 2730 -770 704 199 b) Roomvenfilason _ 0 0 0 0 13 IntenalgainS Omrpants;Q 230 6 1380 2 460 Applianoesrofier 1000 0 Subbtel(lines6to13) 18198 17140 4467 4152 Lessedemalload 0 0 0 0 Lesstransfer 0 0 0 0 Redisbibuton 0 0 0 0 14 Subtotal 18198 17140 4467 4152 15 Dudlcads 330/6 53-A 5997 9058 33% 53% 1472 2194 Total room load I 1 24194 26198 5939 6347 Airrequired(dm) 1 1160 1160 285 281 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. " wrmll d t- 2019-SepA710A148 RigltStite&Lkiwml20l9l9.O.O7 RSW81D1 Page 1 _CIWYMJE-THE GRAND C4RLTON.WnHSnTING ROOMnp Cale=MJ8 FrortDoorfaces:N wrightsoftt Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317ST. LUCIE LN,Fr.. PIERCE, FL 34946 Phom:772-466-6799 Fax772-466-6796 Email: QU1CKCALCS@AOL.COM 1 Roamnarre VdC MBATH 2 ExpoedwOl 0 ft 8.0 ft 3 Room height 8.0 ft heaVmol 8.0 ft hwV=i 4. Room dimensions 7.0 x 9.0 ft 7.0 x 8.0 ft 5 Roomarea 63.0 fP 56D ft Ty Condlydon LI-value Or HTM Area (fe) Load Area (R' Load number (Btuh*-n (BWWft°) or perimeter (f) (BVrh). a perimeter (M (Suh) Heat Cad Gros NRVS Heat Cod Gros N/P/S Heat Cool 6 13A-0cis _ _ .. 0.143 - ne 4.00 2S5 '0 0 0 . _ 0 _ __ 0 _ .0 0 _0 _0 I--G ll-� tAtIoin 1270 ne 35.56 70.43 0 0 '0 0 0' 0 0 0 11D0 - _ _ 0.390 ne 10.92 11.31 0 0 0 0 0 0 0 0 --_DDD_ �-G 134-4ors 0.143 se 4.0D . _ 2.55 _ 0 _ 0. p 0 - 0 . _ 0 _ U _..__0 11 1Aclom 1270 se 35.56 34.77 0 0 0 0 0 0 0 0 �_ D 11DO - _ - 0.390 a 10.92 11.31 0 0 0 0 0 0 0 W ._ 13A-0&s___.. _ 0.143 s _ _4.00 _ 2.55 _ _0. _0 __ 0 0 ._ 0 0 -_ 0 _ 0. _ _0 y 0 W, 13A4a5 0.143 sv 4.00 2.55 0 - - 0 0 64 _ 57 _ _ 228 - - 145 T_1' 1Ac1om _ _ _1270 w 35.56 42.91 0 0 '0 0 7 5 247 298 IW _ 134-4a9 _ 0.143 nw _ _ 4.00 _ yam. _0 _ ._ _0 _ 0 _ _ 0 _ 0. _ __ 0 _ .._ 0.___ 0 - 1Aciom 1270 w 35.56 4524 0 0 0 0 0 0 0 0 ._ 4A5-2om_. _.. 0.770 .m _ 21.56 20.11 .._ 0__._ 0_ 0_ 0 P 12C-0sw 0.091 255 128 0 _ 0 0 0 0 0 0 0 0.__.. 164-30md 0.989 _ _.7.69._ _ 2.32 ___ 63 63 56. 50 F.__... �"�_.____ ___ 0.989 - ZLfi9 0.00 _ 63 .._ 0 ._ .... 0 .__.140 ... 0 _.. _ .56 .56 _56_ _ 8 _ _ 712 __1.0 �0 6 c)APC emrrsion -7 196 Penelope loslgain 56 140 747 768 12: a)Infiltation 0 0 137 39 b) Roomverrilabon 0 0 0 0 13 Internal gains Ooarpanfs@ 230 0 0 0 0 Appliartresrdher 0 0 Sublolal(Ilneslit113) 56 140 884 807 Lese+demalload 0 0 0 0 Lestansfer -0 0 0 0 R�stibuh'on 0 0 0 0 14 Subbfal 56 140 884 BD7 15 Dudloads 33% 53% 19 74 33% 53°Aa 291 427 Total room load 75 -213 1176 - 1234 Air regdred(dm) 4 9 56 55 Calculations approved bvACCAto meet all reauirements of Manual J 8th Ed -'I+' - - - 201Mep-1710:41:48 Pog-WITH ®tYire ROOI1 p Ca7RS1J08101 Page2 _CIWYNNE-THE GRAND CARLTOPFWfiH SRTING ROOMnq CaIc=MJB Frod Door farEs N wrightsoft- Right-M) Worksheet Job: Entire House Date: QUICK CALM, INC. ar. 317ST. LUCIE M,Fr. PIERCE, FL 34946 Plow 772-466-6799 Faz772-466E796 Email: QUICKCALCS@AOL.COM 1 Roomnarne KITCHEN BATH 2 3 Exposedwall Room height 0 It 8.0 ft heaNmol 5.0 ft BA It heaVbool 4 6 Room dimensions Roomarea 1.0 x 1920 it 192.0 If 9.0 x 5.0 It 45.0 fe Ty Con9nlmon U-value Or HTM Area (f* Load Ala (fe) Load number (BUIr-T) (BtuW or pedmehs (iq (Btuh) or perimeter (8) (BNh) Heat Cool Gross NIPS Heat Cool Gross N/P/S Heat Cool 0 lQ{!—�' 13AAois _ 1Ac1om 11DO 0.143 1270 0.390 ne ne - ne 4.00 35.56 10.92 Z65 70A3 11.31 0 0 0 0 0 0 _0 0 0 0 0 0 40 0' 0 40 0 0 _ 160 0 0 102 0 0 —D T0 11 13A4as 1Ac1om 0.143 1270 se se 4.00 35.56 - 2,55 34.77 0 0 0 0 0 0 0 0 0 0 0 0 0' 0 -0 � _11DO _ 13A40c _ _ _ laA-4= 1A Iom _ _ _ 13A-4= 0.390 _ 0.143 0.143 _ 1270 0.143 se_10.92 s _ sN _ w35.56 w 4.00 4.W 4.00 11.31 _ 2S5 2,55 42.91 255 _0 0 _. 0 _ 0 0 0 0 _ _0 __ _ 0 0- 0 0 _ 0 _ _ 0 0 0 0 0 _ _ 0 0 0 0 _ _0 _ 0 0 0 _ 0 _ _0 0 0 0 '0 -0 0 0 0 _ ._ 0 0 _ 0 0 W �j �C 1Aclom 1270 w 35.56 4524 0 0 0 0 0 0 0 0 4lS20m __. _ _ _ _ 0.770 _ w 21.56 _2011 _ 0- 0 0 0 0- 0 0 P 12C-O w 0.091 255 128 64 64 _ 163 82 0 _ 0 _0 0 _ 0 C _ 16A 3Wmd Q032 _ - _ 0.90 2.32 _ 192 192 172 � 445 _ 45 45 _ 40 _ _ 104 F._ _. �-� ._ _. .._R989 27.69 0.00 192 0 0 0 -_. 45 _5 _ _138- _ _ _ 0 6 c)AEDexwson -90 -10 Emelopelosigain 335 438 339 196 12 a). WIlration 0 0 86 24 b) Roomlentlation 0 0 0 0 13 Internal gains 0—pants@ 230 2 460 0 0 Applianasrofier 1000 0 SubbblQineSMD13) 335 1898 425 220 Lesextemalload 0 0 0 0 Lestransfer Redstribution 0 0 0 0 0 0 0 0 14 Sulebtdl 335 1898 425 220 15 DuCloads 33°/a 63% 110 1003 33% 53% 140 116 Total room load 1 1 446 2901 565 336 Air required (Um) 21 128 27 15 ,.ram Calculations approved byACCA to meet all requirements of Manual J 8th Ed. C -rld- o�>R2019-Sep�1710.41:48 RIgN.StiteG Uriwrml20l9l9.O.O7 RSW8101 Page 3 _CWMWE-THE GRAND CARLTOKWITHSRTING ROOMnp Calc=MJB FinaDoorfaas:N wrightsofr Right-J® Worksheet Job: - Entire House Date: QUICK CALCS, INC. ay 317 ST. LUCIE LN.. FL PIERCE. FL 34946 Phoe:772-465-6799Fax772-466-6796 Email: OUICKCALCS@AOL.COM 1 Room name BEDROOM2 ENTRY 2 EVosedxell 312 ft 7.0 It 3 Room height 6.0 ft heatl=l 8A It heatkool 4 5 Room dimmsio Rooma 1.0 x 203.5 It 203.5 fl 61.0 1.0 x 61.0 ft fF Ty Construction U-value Or HTM Area (ft') Load Area (ft?) Load number (BtjhW-'9 (BIuMP) a Pedmetar (M (Bbh) or pedmeta (ry (Btuh) Heat Cod Gmss N/PS Heat Cool Gnx N/P/S Heat Cool 6 IN —LDC, 13A-00[s 0.143 ne 4.00 2.55 128 128 513 326 0 0 0 0 1AcIom 1270 ne 35.56 70.43 0 0 0 0 0 0 0 0 11DO 0.390 ne 10.92 11.31 0 0 0 0 0 0 0 0 _ M-40 s 0.143 w 4.00 255 _ 80 56 225 143 48 26 - 106 - 67 1 i T. 1A V om 1270 se 35.56 34.77 24 24 848 829 0 0 0 0 11DO 0.390 se 10.92 11.31 0 0 0 0 22 22 236 W_ _ _ laA40s _ _ 0.143 s. 4.00 255 34 34 _ 136 86 - 0 - 0- - 0 _ _244 - 0 wI � �----G laA-4 s 1Actom 0.143 1270 w w 4.00 35.56 _ 255 4291 _ 8 0 8 0 _ 32 0 - - 20 0 - -8 0 - 8 0 - 32 0 - — 20 0 w _ 13A-4= 0.143 _ w 4.00 .. 255 _ 0 _ _ 0 0 _ 0 0 0 _ _ .0 . _ 0 1Aclom 1270 w 35.56 4524 0 0 0 0 0 0 0 0 4AS2om _ _ _ 0.770 w 21.56 0 0 0 0 0 0 0 0 P 12C-Ow 0.091 255 _2011 128 _ 0 - _ 0- 0 _ 0 . _ 80 _ 80 _ _ 204 103 _ C _- 16430md- 0.032 _ _ - 0.90 232 204 204 182 472 _ '61 61 - 4_ 55 _ - 142 _ 0.989 - -27.69 0.00 _ --- 204 _ 31 _ 8w .._. 0 61 _ _ 7 _ -194 _ _ 0 6 o)AED exvusion -92 -28 Enydopeloss/gain 2799 1785 826 548 12 a) Infiltafion 537 151 120 34 b) Rmn%entilation 0 0 0 0 13 Intunal gaits O—pants@ 230 0 0 0 0 Appriances/olhcr 0 0 Subbtal(lines6to 13) 3336 1937 946 582 Lessex2rtWload 0 0 0 0 Less7anster 0 0 0 0 Redistribufion 0 0 0 0 14 Subloml 3336 1937 946 582 15 Duo:loads 33% 53% 1099 1023 330/0 53% 312 308 Toal loom load ad 4435 2960 960 1258 690 Airrequiled 213 60. Calculations approved byACCAto meet all requirements of Manual J 8th Ed. !` i'� wrlat!m '.t- 2019Sep-1710:41A8 Pogt4SuteSUiwrsa1201919.0.07 RSL08101 PageAl _aWY NE -THE GRAND CARLTON-WIT-ISmING ROOMnp Cale-W8 FmADoorfaces: N wrightsoft Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Phore:772-466-6799 F=772-466-6796 Email: OUICKCALCS®AOL.COM 1 Room name LAUNDRY SRTWG ROOM 2 3 FVosed Y,all Room heigM 6.0 ft 8.0 It heaftol 30.0 ft 8.0 ft heal/cool 4 5 Room dimensi= Roomarea 7.0 x 6.0 It 42.0 ft' 20.0 x 10.0 ft 200.0 IF Ty Cor&ucbon U-value. Or HTM Area (itl Load Area (ft') Load number I (BWh*-F) (Btuhfi* or perimeter (f) (ftm) or perimeter (M (BWh) Heat Cad Gross NIPS Heat Cool Gross NIPS Heat Cool 6 1M �LfD 13440¢7 - - - 1Aciom - 11DO 0.143 1270 0.390 ne m re 4.00 35.56 10.92 2.55 70.43 11.31 0 0 0 0 0 0 0 0 0 0 0 0 -80 0 21 59 0 21 236 0 229 150 0 238 �/ I-G 11 - 134-4= 1Ac1om 0.143 1270 se se 4.00 35.56 2,55 34.77 "0 0 - 0. 0 _0 0 -. 0 0 0 0 0 0 - 0 0 - 0 0 �D W _ W 11DO _13A-4om _ 13A-4= 1A Iom _ _ _ 13A-4= _ 0.390 0.143 0.143 _ 1270 0.143 se _ s" sw sm w 10.92 _ 4.00 4.00 _ 35.56 4.00 _ 11.31 _ 255 255 4291 255 _ _0 _ 0 48 0 0 0 _ _ 0 48 0 0 0 0 192 0 0 0 _ 0 " 122 0 0 __ _ 0 0 0 _ 0 160 0 0 -'. . - 0 _ 0 122 0 0 - - 0 0 -489 _ 0 0 -" .0 0 311 P 1Aclom 4AS2om _ _ _ 12C-Ow 1270 _ .. _ 0.770 0.091 m m - 35.56 _ 21.56 2,55 4524 _ 20.11 128 0 _ -0- 56 0 . .0 56 0 0 143 0 _ 0 72 0 _ 38 0 0 0 0 0 , _ _ 815 0 0 _ 760 0 C ... F _ 16A-30md, _ _, _ 27A-fpl _ _ __ 0.989 _ 0.989 -_ - _ 7.90 2/.69 . ,.0.00 0.00 _. _ 42 42 _.. 42 6 _ 38 166 _ 97 0 _ _ 200 200 _ _ _ 200 30 _ 831 831 _484 0 6 c)AED e=rsim -14 367 Fmelopelossfgain 539 277 2780 2290 12 a) k tdon 103 29 515 145 b) Rcomvenlilaton 0 0 0 0 13 Inbamal gains Ocapants@ 230 0 0 0 0 Applianoestotler 0 0 SubtOW(llnes6t113) 642 306 3295 2435 Lesse#emal load 0 0 0 0 Lesstansfer 'l 0 0 0 0 14 Redigbi on Subt1W 0 642 0 306 0 3295 0 2435 15 Ductloads 33% 53% 211 162 33% 53% 1086 1287 TOW roan load 853 468 4381 3722 Airmquired(dm) 41 21 210 165 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrtphlacrft' - 2019SepA710:41:48 Righ4SLite4DUimml20l9l9.0.07 RSW8101 Page 5 .-QWYNNE-THE GRAND CARLTOP1WfrH SnnNG ROOMxW Calc=MJ8 FroNDoorfaces:N wrightsofC Right-J®Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 STLUCIE LN, Fr. PIERCE, FL34946 Phone:772-468-6799 Fax7724666796 Email: QUICKCALCSQAOL.COM 1 Roomname GREADDINING 2 Exposadvell 25.0 It 3 Room height 92 ft heaymol 4 5 Room dimensions Room area 1.0 x 468.0 ft 468.0 fe Ty Construmon number U-value (BNh4tz°F) Or HTM (Bbhllt) Area (ft� or perimeter (fl) Load (BWh) Area a pedmfihr Load Heat Cod Gross NOS Heat Cool Gros NrPIS Heat Cool 6 V)J lak4ccs 0.143 ne 4.00 2.55 245 207 830 - - 527 -- - - - 1Ac1om 11D0_ 1270 _ 0.390 ne - ne 35.56 10.92 70.43 11.31 38 0 0 0 1344 2562 0 �L—(D' lQ/ 11 134-0as 1270 ss se 4.56 255 0 0 0 0 _ _0 0 0 0 0 =9 11DOIAcl 134-0ats _ 13A- 13A4as IA-dom 13A4oe 0390 0.143 0.143 0.143 1270 0.143 a s sY w nw 10.92 _ 14.00 4.00 4.00 35.56 4.00 11.31 11.31 2.55 2.55 42.91 Z55 _ 0 0 - 0. 0 - .0 0 0- _ - 0 0 _ - 0 0 .. 0 0 - 0.. 0 _ 0 0 0 W _ - W L—G IW 1Ac1am 1270 RN 35.56 4524 0 0 0 0 �G 4A5-2om. _ _ . .. _ 0.770 w _ 21.56 20.11 0 0 0 o P C -- -- 12C6sw _16A Whncl 0.091 0.032 -0.989 - __ 255 _.0.90 128 232 _ 0 468 - 0 468- 0 419 - 0 - 1086 - - - - - - - - - - - F 22A_yl - 27.69 0.00 468 _ _ 25 692 - 0 _ 6 o)AED ad. 221 En,Mopelossfgain 3285 4055 12 a) InflMon 526 148 b) Roomlentlatoo 0 0 13 Intanalgains Ornrpants@ 230 2 460 P.ppfancesrolher 0 Subbtal Qines66713) 3812 4663 Lesswernalload 0 0 Lesstransfer 0 0 Redistribution 0 0 14 Subbml 3812 4663 15 Duo:loads 33% 53°k 1256 2464 Total room load 5068 7127 Airmquired(&n) 243 316 Calculations approved bvACCAto meet all reauirements of Manual J Sth Ed '*" 2019-Sep-1710:41:48 RigtFSuteO kiw=1201919.0.07RSWS701 Page .-QWYNNE-THEGRANDCARLTONWDHSrMNGROOMnp Calc=MJB Froit Doorfaces:N wrightsoft° Duct System Summary Data: Entire House By. QUICK CALCS, INC. 317 ST LUCIE UN., FT.PIERCE, FL 34946 Piow772-466-6799F=772-46M798 Em iI:OUICKCALCS@AOL.COM P-roject Intormation For. WYNNE DEVELOPMENT - GRAND CARLTON WITH SITTING, FT. PIERCE, FL Extemal static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.287 in/100ft 1160 cfm 174 Supply Branch Detail Table Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250/0.250 in H2O 0.287 in/100ft 1160 dim Name Design (Btuh) HIg (cfm) Clg (cfrn) Design FIR Diam (In) HxW (In) Duct Mat Actual Ln (ft) Ftg.ECIv Ln (ft) Trunk BATH h 565 27 15 0.375 4.0 Ox0 VIFx 18.3 115.0 st1 BEDROOM2 h 4435 213 131 0.360 7.0 OxO VIFx 23.8 115.0 st1 ENTRY h .1258 60 39 0.513 4.0 OxO VIFx 2.5 95.0 GREATAANNG c 3564 121 158 0.312 7.0 OxO VIFx 25.1 135.0 st2 GREATAXNNG-A c 3564 121 158 0.293 7.0 OxO VIFx 35.9 135.0 st2 KITCREN c 2901 21 128 0.370 7.0 Ox0 VIFx 20.2 115.0 st1 LAUNDRY h 853 41 21 0.357 4.0 Ox0 VIFx 25.1 115.0 st1 M. BATH h 1176 56 55 0.356 4.0 OxO VIFx 25.5 115.0 st1 MASTERBEDROOM h 2969 142 140 0.287 7.0 OxO VIFx 39.0 135.0 st2 MASTERBEDROONLA h 2969 142 140 0.298 7.0 Ox0 VIFx 32.7 135.0 st2 SITTING ROO6trA h 4381 210 165 0.288 7.0 OxO VIFx 38.5 135.0 st2 "IC c 213 4 9 0.308 4.0 Ox0 VIFx 1 27.3 135.0 st2 . Supply Trunk Detail Table Trunk Htg Clg Design I Veloc Diam H x W Dud Name Type (cftn) (dim) FR (Tpm) (n) Qn) Material Trunk st2 PeakAVF 741 771 0.287 981 12.0 0 x 0 YnlFlx st1 st1 PeakAVF 1100 1121 0.287 1048 14.0 0 x 0 VInIFIX C wriphtso 1.49 I wgN,SUre®IYiwrsa1201918.0.07RSW8101 201&Sep171 P3ge1 Page 1 nwr�._G1WMWE-TFff= GRAND CARLTOPLWfr}iSfl-PINGROOMnq CeIc=MJB FroADaorreces N Return Branch Detail Table Name Grille Size (in) Htg (cftn) Clg (cfin) TF1 (ft) Design FR Veloc (ipm) Diam (in) H x W (in) Stud/Joist Opening (n) Dud Matl I Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 VIFx Wright50ft- 2019-Sep1710.41.49 Wgtt-Sute3LkiwrwI 201919.0.07 RSW8101 Page ...QWYMJE-THEGRANDCARLTINaWRHSn-nNGR00Mnp Calc=MJ8 Fro2Doorfaaes:N