Loading...
HomeMy WebLinkAboutREVISION - BUILDING PERMITOFFICE USE ONLY: DATE FILED: REVISION FEE: 7 S 1. PERMIT #- 1908-0462 a d 0 i RECEIPT # O I PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772) 462-1553 FAV 072) OX-1570 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/S59FEDTI'ERRANEANNORTH ADDRESS: 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: RECEIVED APR 15 2020 Permitting Department St. Lucie, County CHANGE WATER HEATER FROM A 40 GAL. TO A-50 GAL. AND CHANGE TO IMPACT WINDOWS 3. CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: ST. LICIE COUNTY CERT. #:. 8898 BUSINESS NAME: Corpora on QUALIFIERS NAMEb South U uI e ADDRESS: 8l)UU wy 402 CITY: Fort Nt. Lucie STATE: ZIP: PHONE (DAYTIME): 878-5513-- FAX: 772) 878-7656 4. OWNER/BUILDER INFORMATION: NAME: Wynn Building Corporation ADDRESS: Suite402 CITY: STATE:FL PHONE: (772) 878-5513 FAX: 5.-ARCHITECTBNGINEERINFORMATION: NAME: BRADEN & BRADEN ADDRESS: 417 COCUN U fAVE. CITY: STLT PHONE (DAYTIME): Revised 07/22/2014 q1 STATE: FL ZIP: 34996 FAX: REVISION FILE COPY \,: \ VIz�- - U�_\ (O;�_ FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ProjectName: WYNNE DEV GRAND CARLTON SITTING impact BuilderName: WYNNE DEVELOPEMNT Street: nl\� f\tea - �� � Permit Office: ST. LUICE COUNTY City,Stale,Zip: FT. PIERCE, FL, PermitNumber: Owner: Jurisdiction: ST. LUCIE COIUNTY DesignLocationi FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1., New construction or e)isting. New (From Plans) 9. Wall Types(1571.1 sgft.), Insulation Area 2. Single familyor multiple family Single-family a. Concrete Block- Int lnsul, Exterior R=4.1 1443.10 ft2 b. Concrete Block -1nl Insul, Adjacent R=11.0 128.00 W 3. Numberof units, if multiple family 1 c. N/A R= ft2 4.Number of Bedrooms 2 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1646.0 sgft.) Insulation Area - a. UnderAttic(Vented) R=30.0 1646.00 ft2 6. Conditioned Floor area above grade (ft2) 1646 _ b. N/A R= f2 Conditioned Floorarea belowgrade(ft2) 0 R= - D 11.Ducts Rs ft2 7. Windows(138.8 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 275 a. U-Factor. Sgl, U=1.04 138.75 ft2 - SHGC: SHGC=0.29 - b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: d. U-FactSHGCor. NIA _ 13. Hee(abnnrg� systems tu/ E en@@@@���� 4.8SHGC: a uV 1 E%rems Overhang Depth: 2.209 ft. Area Weighted Average SHGC: 0.290 KKK■■■ddd wWWaaa���r���rrrAreaWeightedAverage 14a t S. Floor Types (1645.5 sgft.) Insulation Area a. Electric Cap:50 gallonsEF: a. Slab -On -Grade Edge Insulation. R=0.0 1645.50 ft2 0.950 b. Conservation features p b. N/A R= - ft2. None Gatti D _ 0, c. N/A R= - ft2 15. Credits CF. Patel Glass/Floor Area: 0.084 Total Proposed Modified Loads: 53.49"ftVIEWED F L+�+ r/ - ss Total Baseline Loads: 5 DE COIl I !�/tip�,-f��f- I hereby that the by LUCIE COUN / certify plans and specifications covered this calculation in the Florida Energy Review of the plans and �+/v CC are compliance with specifications covered b p Code. _62 calculation indicates compliance with the Florida Energy Code PREPARED BY: Before construction is completed DATE: - this building will be inspected for t9 - _ y . - compliance with Section 553.908 N �, I hereby certify that this building, as designed ' mpliance Florida Statutes. FILE C - with the Florida Energy Cod OWNER/AI BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). RECEIVED APR 1 5 7n?n Permitting Deperun%r,, St. Lucie rnpep,. 4/9/20209:49 AM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1. of (2D21 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Tille: WYNNE DEV GRAND CARLT Bedrooms: 2 Address Type: Street Address Building Type: User ConditionedArea: 1646 Lot# OwnerName: Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: BuilderName: WYNNE DEVELOPEMNT RotateAngle: 270 Street: Permit Office: ST. LUICE COUNTY CrossVentilation: No County: St. Lucie Judsdiction: ST. LUCIE COIUNTY Whole House Fan: No City, State, Zip: Fr. PIERCE, FamilyType: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / DesignTemp Int Design Temp Heating Design DailyTemp V Designi-ocation TMYSite 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1646 15472.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 252 2368.8 No 0 1 1 Yes Yes Yes 2 WIC 63 592.2 No 0 1 No Yes Yes 3 MASTER BATH 63 592.2 No 0 1 Yes Yes Yes 4 M. BATH 56 526.4 No 0 1 Yes Yes Yes 5 KITCHEN 192 1804.8 Yes 0 1 No Yes Yes 6 BATH 45 423 No 0 1 Yes Yes Yes 7 BEDROOM 2 204 1917.6 No 0 1 1. Yes Yes Yes 8 ENTRY 61 573 No 0 1 Yes Yes Yes 9 LAUNDRY 42 395 No 0 1 Yes Yes Yes 10 SITTING ROOM 200 1880 No 0 1 Yes Yes Yes 11 GREAT/DINING 468 4399 No 0 1 Yes Yes Yes FLOORS # FloorType Space Perimeter PerimeterR-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BEDROOM 32ft 0 252 112 ---- 0 1 0 2 Slab -On -Grade Edge Insulation WIC 1 ft 0 63 ft2 ---- 0 1 0 3 Slab-On-GradeEdge Insulation MASTER BATH 9ft 0 63 ft2 ---- 0 1 0. 4 Slab -On -Grade Edge Insulation M.BATH 8ft 0 56 ft2 _--- 0 1 0 5 Slab -On -Grade Edge Insulation KITCHEN 1 ft 0 192 112 ---- 0 1 0 6 Slab -On -Grade Edge Insulation BATH 5ft 0 45 ft2 ---- 0 1. 0 4/9/2020 9:49 AM EnergyGauge® USA 6.0.02 (Rev.1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 7 Slab-On-GradeEdgelnsulation BEDROOM 31.2ft 0 203.5 ft' ---- 0 1 0 8 Slab-On-GradeEdge Insulation ENTRY 7ft 0 61 ft' --_- 0 1 0 9 Slab-On-GradeEdgelnsulation LAUNDRY Eft 0 42 ft' _-_- 0 1 0 10Slab-On-Grade Edge Insulation SITTINGROOM 30ft 0 200 ft2 -_-_ 0 1 0 11Slab-On-GradeEdge Insulation GREATMINING 25ft 0 468 ft' ---- 0 1 0 ROOF J Roof Gable Roof Rod Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 GableorShed Metal 1735ft2 274 ft- Light N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 In) Area RBS. IRCC 1 Full attic Vented 300 1646 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 UnderAttic(Vented) BEDROOM 30 Blown 252 ft2 0.1 Wood 2 UnderAttic(Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 UnderAttic(Vented) MASTER BATH 30 Blown 63 ft' 0.1 Wood 4 UnderAttic(Vented) M..BATH 30 Blown 56 ft' 0.1 Wood 5 UnderAttic(Vented) KITCHEN 30 Blown 192 ft' 0.1 Wood 6 UnderAttic(Vented) BATH 30 Blown 45ft' 0.1 Wood 7 UnderAttic(Vented) BEDROOM 30 Blown 204 ft' 0.1 Wood 8 UnderAtBc(Vented) ENTRY 30 Blown 61 ft' 0.1 Wood 9 UnderAttic(Vented) LAUNDRY 30 Blown 42 ft' 0.1 Wood 10 UnderAtBc(Vented) SITTING ROOM 30 Blown 200 ft2 0.1 Wood 11 UnderAtBc(Vented) GREAT/DINING 30 Blown 468 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE=>NW Exterior Concrete Block-Int lnsul BEDROOM 4.1 18 0 9 5 169.5 ft2 0 0 0.4 0 2 NW=>S Exterior Concrete Block- Intlnsul BEDROOM 4.1 14 0 9 5 131.8 ft2 0 0 0.4 0 3 NE=>NW Exterior Concrete Block- Int lnsuMASTER BA 4.1 9 0 9 5 84.8 ft2' 0 0 0.4 0 4 NE=>NW Exterior Concrete Block- Intlnsul M.BATH 4.1 8 0 9 5 75.3 ft' 0 0 0.4 0 5 SW=>SE Exterior Concrete Block- Intlnsul BATH 4.1 5 0 9 5 47.1 ft2 0 0 0.4 0 6 NE=>NW Exterior Concrete Block- Int lnsuBEDROOM 2 4.1 1 0 9 5 9.4ft2 0 0.4 0 7 E=>N Exterior Concrete Block- Int lnsuBEDROOM 2 4.1 4 3 9 5 40.0W 0 0 0.4 0 8 SE=>NE Exterior Concrete Block- Int lnsuBEDROOM 2 4.1 10 0 9 5 94.2 ft' 0 0 0.4 0 4/9/2020 9:49 AM EnergyGauge® USA 6.0.02 (Rev. 1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Spam Cavity Width P Height Sheathing Framing Solar Below o _9 SW=>SE Exterior Concrete Block- Int lnsuBEDROOM 2 4.1 16 0 9 5 150.7 ft2 01 0 0.4 0 10 NE=>NW Exterior Concrete Block-Int lnsul ENTRY 4.1 1 0 9 5 9.4 ft2 0 0 0.4 0 11 SE=>NE Exterior Concrete Block-Intlnsul ENTRY 4.1 6 0 9 5 56.5 ft2 0 0 0.4 0 12 NE=>NW Exterior Concrete Block- Int lnsul LAUNDRY 4.1 6 0 9 5 56.5 ft2 0 0 0.4 0 13 SW=>SE Exterior Concrete Block- Int lnsuBITTING RO 4.1 10 0 9 5 94.2 ft2 0 0 0.4 0 14 NW=>S Exterior Concrete Block-IntlnsuBITTING RO 4.1 20 0 9 5 188.3 ft2 0 0 0.4 0 15 SW=>SE Exterior Concrete Block -Int lnsuGREAT/DINT 4.1 25 0 9 5 235.4 ft2 0 0 0.4 0 16 N=>W Garage Concrete Block- Int lnsuBEDROOM 2 11 16 8 128.0 ft2 0 0.4 0 DOORS # Omt DoorType Space Storms U-Value Width Height Area Ft In Ft In. 1 SE=>NE Wood ENTRY None -.39 3 1 7 21.6 ft2 2 SW=>SE Insulated SITTING RO None .39 3 7 21 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation IntShade Screening 1 NW=>SW2 Metal Low-ESingle Yes 1.04 0.29 Y' 32.9 ft2 1ft51n 1ft5in Drapes/blinds Exterior5 2 NE=>NW 4 Metal Low-ESingle Yes 1.04 0.29 Y 6.9 ft2 1 ft 5 in 1 ft 5 in None None 3 SE=>NE8 Metal Low-ESingle Yes 1.04 0.29 Y 24.0 ft2 6ft0In 1ft5.in None None _ 4 NW=>SW14 Metal Low-ESingle Yes 1.04 0.29 Y 37.5 ft2 1ft5in 1ft5im None None 5 SW=>SE15 Metal Low-ESingle Yes 1.04 0.29 Y 37.5 ft2 tft5in 1ft5 in None None GARAGE # FloorArea CeilingArea Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation ' 1 ' 320 ft2 320 ft2 16 ft 8 ft 11 INFILTRATION '# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse PmposedACH(50) .000299 1289.3 70.78 133.12 .1104 5 HEATING SYSTEM # System Type Subtype_ Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Single HSPF:8.5 34.8 kBtu/hr 1 sys#1 4/9/20209:49 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4of5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 CentralUnit/ Split Single SEER: 15 34.8 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type S,bType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage - Cent # CompanyName System Model# CollectorModel# Area Volume FEF None None ft2 DUCTS Supply— —Return— Air CFM25 CFM25 HVAC# V # .Location R-Value Area Location Area LeakageType Handler TOT OUT QN RLF Heat Cool 1 Attic 6 275 ft2 Attic 65 ft' Defaulti-eakage Attic (Default) c(Default) c 1 1 TEMPERATURES ProgremablerXT,Jhermostat[ Ceiling Fans: ]Y Heating Jan H Feb fx]], N Mar �[X [D0] Jul M Aug 4X]� r[X'] Nov Dec H Venting I I Jan (1 Feb l l IXl Mar Apr May [ Jun [ ]Jul Aug (] Sep Oct [ ]X Nov Dec ThermostatSchedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Ccoling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM, 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD)• AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 '66 66 MASS Mass Type Area Thickness FumilureFraction Space Default(8 lbslsq.fL 0 ft' 0 ft 0.3 BEDROOM Default(8lbs/sq.ft. ft2 ft 0.3 WIC Default(81bs/sq.ft. ft' ft 0.3 MASTER BATH Defaull(8 lbs/sq.ft. ft2 ft 0.3 M. BATH Default(81bs/sq.ft. ft' ft 0.3 KITCHEN Default(Blbs/sq.ft. ft2 ft 0:3 BATH Defaul48 lbslsq.ft. ft2 ft 0.3 BEDROOM Default(81bs/sq.f. ft2 ft 0.3 ENTRY Default(Blbs/sq.ft. ft2 ft 0.3 LAUNDRY Default(81bs/sq.ft. ft2 ft 0.3 SITTING ROOM Default 8lbs/s .ft. ft' ft 0.3 GREATIDINING 4/9/2020 9:49 AM EnergyGaugeO USA 6.0.02 (Rev. 1)-FlaRes2017FBC 6th Edition (2017) Compliant Software Page 5 of 8 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE DEV GRAND CARLTON SITTING impact Builder Name: WYNNE DEVELOPEMNT Street, Peroil Office: ST. LUICE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y U Owner. Jurisdiction: ST. LUCIE COIUNTY w Design Location: FL, Fort Pierce c=i COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access. openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction. of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed • walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall. be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvenled crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac 3s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing In exterior walls, or insulation that on installation readily conforms to available space shall extend hphond pining grid wiring Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electricallphone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 4/9/2020 9:49 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 .2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home, 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b). Return ducts R 6.0 c) AMU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1646 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.040 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.290 14. Heating system: Capacity 34.8 c) Area 7c. 138.8 a) Split system heat pump HSPF 8.5 b)Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.1 15. Water heating system a) Electric resistance EF 0.95 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ 0 Heat recovery unit HeatRec%o g) Other 10B1. 1082. 11.0 16. HVAC credits claimed (Performance Method) a) Ceiling fans Yes 11a. 30.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed co compliant features. (�1 Builder Signature: � Dater Address of New Home: `iS `i�9��` I`\^4^'ti-QC� City/FL Zip: FT. PIERCE. FL 4/9/2020 9:49:31 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017)Compliant Software Page 1 of 1 OFFICE USE ONLY: DATE FILED- REVISION FEE: LOCATION/SITE ADDRESS: PERMIT # RECEIPT # PLANNING & DEVELOPMENT SERVICES SCANNED BUILDING & CODE REGULATION DIVISION % LUCIB �'OUIIQI/ 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 (772)462.1553 APPLICATION FOR BUILDING PERMIRRWISIONI PROJECT INFORMATION DETAII,ED DESCRIPTION OF PROJECT REVISIONS: CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS:. CITY: STATE: REVIEWED FOR CODE �� �COMPLIANCE ST. LA E (g kQW. #'®LINTY PHONE (DAYTIME): FAX: OWNER/BUILDER INFORMATION: NAME: IL-j )IJ !J !J e- l3 4 ADDRESS: S-� d S c c S 1 CITY: Pam- L STATE: PHONE (DAYTIME: 77Z 2y I- 8-S' y 3 FAX: ARCFIITECT/ENGINEER INFORMATION: TUIU CITY: PHONE (DAYTIME): SLCCC. 9123109 Revised 06130117 STATE: ZIP: ZIP: . FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE DEV GRAND CARLTON SITTING Builder Name: WYNNE DEVELOPEMNT Street: 78 MEDITERRANEAN NORTH Permit Office: ST. LUICE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: 1908-0462 Owner: Jurisdiction: ST. LUCIE COIUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1571.1 soft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1443.10 ft' b. Concrete Block - Int Insul, Adjacent R=11.0 128.00 IF 3. Number of units, If multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 2 d. N/A R= ft' 5. Is this a worst case? Yes 10. Ceiling Types (1646.0 soft.) Insulation Area a. Under Attic (Vented) R=30.0 1646.00 ft- 6. Conditioned Floor area above grade (ft') 1646 to. N/A R= ft' Conditioned floor area below grade (M) 0 c. N/A R= ft' 11. Ducts R ft' 7. Windows(138.8 soft.) Description Area a. Sup: Attic, Rat: Attic, AH: Attic 6 275 a. U-Factor: Sgl, U=1.04 138.75 ft' SHGC: SHGC=0.29 b. U-Factor: NIA R2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.692 ft. Area Weighted Average SHGC: 0.290 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1645.5 soft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1645.50 ft' b. Conservation features b. N/A R= ft` None c. N/A R= ft. 15. Credits CF, Pstat Glass/Floor Area: 0.084 Total Proposed Modified Loads: 53.15 PASS Total Baseline Loads: 53.81 1 hereby certify that the plans and specifications covered by Review of the plans and F ($B SrgT this calculation are in compliance with the Florida Energy specifications covered by thisO� Code. calculation indicates compliance with the Florida Energy Code. I: fill n"Cf, PREPAR DATE: Before construction is completed this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. !,) with the Florida Energy Code. COp WE OWNER/AGENT: BUILDING OFFICIAL: DATE: o-45P DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 12/9/2019 6:20 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 FORM R40'5-2017 INPUT' AMARY CHECKLIST REPORT PROJECT Title: WYNNE DEV GRAND CARLT Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1646 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPEMNT Rotate Angle: 270 Street: Permit Office: ST. LUICE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COIUNTY Whole House Fan: No City, Stale, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House IBM 15472.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 252 2368.8 No 0 1 1 Yes Yes Yes 2 WIC 63 592.2 No 0 1 No Yes Yes 3 MASTER BATH 63 592.2 No 0 1- Yes Yes Yes 4 M. BATH 56 526.4 No 0 1 Yes Yes Yes 5 KITCHEN 192 1804.8 Yes 0 1 No Yes Yes 6 BATH 45 423 No 0 1 Yes Yes Yes 7 BEDROOM 2 204 1917.6 No 0 1 1 Yes Yes Yes 8 ENTRY 61 573 No 0 1 Yes Yes Yes 9 LAUNDRY 42 395 No 0 1 Yes Yes Yes 10 SITTING ROOM 200 1880 No 0 1 Yes Yes Yes 11 GREAT/DINING 468 4399 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BEDROOM 32 ft 0 252 ft' ---- 0 1 0 2Slab-On-Grade Edge Insulation WIC 1ft 0 63ft' ---- 0 1 0 381ab-On-Grade Edge Insulation MASTER BATH 9 ft 0 63 ft' ---- 0 1 0 4SIab-On-Grade Edge Insulation M. BATH 8 ft 0 56 ft' ---- 0 1 0 5 Slab -On -Grade Edge Insulation KITCHEN 1 ft 0 192 ft' ---_ 0 1 0 6 Slab -On -Grade Edge Insulation BATH 5 ft 0 45 ft' ---- 0 1 0 12/9/2019 6:18 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPU1:' -'IMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 7 Slab -On -Grade Edge Insulation BEDROOM 2 31.2 ft 0 203.5 ft- ---- 0 1 0 8 Slab -On -Grade Edge Insulation ENTRY 7 ft 0 61 ft' ---- 0 1 0 9 Slab -On -Grade Edge Insulation LAUNDRY Eft 0 42 ft' ---- 0 1 0 10SIab-On-Grade Edge Insulation SITTING ROOM 30 ft 0 200 ft' ---- 0 1 0 11Slab-On-Grade Edge Insulation GREAT/DINING 25 ft 0 468 ft' ---- 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1735 ft' 274 ft' Light N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1646 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 252 ft' 0.1 Wood _ 2 Under Attic (Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 63 ft' 0.1 Wood 4 Under Attic (Vented) M.BATH 30 Blown 56 ft- 0.1 Wood 5 Under Attic (Vented) KITCHEN 30 Blown 192 ft- 0.1 Wood 6 Under Attic (Vented) BATH 30 Blown 45 ft' 0.1 Wood 7 Under Attic (Vented) BEDROOM 30 Blown 204 ft' 0.1 Wood 8 Under Attic (Vented) ENTRY 30 Blown 61 ft' 0.1 Wood 9 Under Attic (Vented) LAUNDRY 30 Blown 42 ft' 0.1 Wood _ 10 Under Attic (Vented) SITTING ROOM 30 Blown 200 ft' 0.1 Wood 11 Under Attic (Vented) GREAT/DINING 30 Blown 468 ft' 0.1 Wood WALLS Adjacent Space Cavity Width ()Mt Tn Wall Type Height Sheathing Framing Solar Below _ 1 NE=>NW Exterior Concrete Block- Int lnsulBEDROOM 4.1 18 0 9 5 169.5 ft' 0 0 0.4 0 _ 2 NW=>S Exterior Concrete Block- Int Insul BEDROOM 4.1 14 0 9 5 131.8 ft' 0 0 0.4 0 _ 3 NE=>NW Exterior Concrete Block- Int InsuMASTER BA 4.1 9 0 9 5 84.8 ft' 0 0 0.4 0 _ 4 NE=>NW Exterior Concrete Block - Int Insul M. BATH 4.1 8 0 9 5 75.3 ft' 0 0 0.4 0 _ 5 SW=>SE Exterior Concrete Block -Int Insul BATH 4.1 5 0 9 5 47.1 ft' 0 0 0.4 0 _ 6 NE=>NW Exterior Concrete Block - Int InsuBEOROOM 2 4.1 1 0 9 5 9.4 R' 0 0 0.4 0 7 E=>N Exterior Concrete Block - Int InsuBEDROOM 2 4.1 4 3 9 5 40.0 ft' 0 0 0.4 0 8 SE=>NE Exterior Concrete Block- Int InsuBEDROOM 2 4A 10 0 9 5 94.2 ft' 0 0 0.4 0 12/9/2019 6:18 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT: \ MMARY CHECKLIST REPORT WALLS Adjacent Space P Cavity Width Height _ e- Ft In Ft In Area Sheathing Framing Solar R_Val Below _ 9 SW=>SE Exterior Concrete Block - Int InsuBEDROOM 2 4.1 16 0 9 5 150.7 ft- 0 0 0.4 0 10 NE=>NW Exterior Concrete Block-Intlnsul ENTRY 4.1 1 0 9 5 9.4 ft' 0 0 0.4 0 _ 11 SE=>NE Exterior Concrete Block- Int Insul ENTRY 4.1 6 0 9 5 56.5 R' 0 0 0.4 0 _ 12 NE=>NW Exterior Concrete Block- Int Insul LAUNDRY 4.1 6 0 9 5 56.5 ft' 0 0 0.4 0 _ 13 SW=>SE Exterior Concrete Block- Int InsuBITTING RO 4.1 10 0 9 5 94.2 ft' 0 0 0.4 0 _ 14 NW=>S Exterior Concrete Block- Int Insu61TTING RO 4.1 20 0 9 5 188.3 ft° 0 0 0.4 0 _ 15 SW=>SE Exterior Concrete Block- Int InsuGREAT/DINI 4.1 25 0 9 5 235.4 ft- 0 0 0.4 0 16 N=>W Garage Concrete Block- Int InsuBEDROOM 2 11 16 S 128.0 ft- 0 0.4 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>NE Wood ENTRY None .39 3 1 7 21.6 112 2 SW=>SE Insulated SITTING RO None .39 3 7 21 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. _ / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SW 2 Metal Low-E Single Yes 1.04 0.29 N 32.9 ft' 2 ft 0 in 1 R 5 In Drapes/blinds Exterior 5 _ 2 NE=>NW 4 Metal Low-E Single Yes 1.04 0.29 N 6.9 ft' 2 It 0 in 1 R 5 in None None 3 SE=>NE S Metal Low-E Single Yes 1.04 0.29 N 24.0 ft' 6 It 0 in 1 ft 5 in None None 4 NW=>SW14 Metal Low-E Single Yes 1.04 0.29 N 37.5 ft' 2 ft 0 in 1 ft 5 in None None 5 SW=>SE 15 Metal Low-E Single Yes 1.04 0.29 N 37.5 ft' 2 ft 0 In 1 ft5 In None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 320 ft' 320 ft> 16 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000299 1289.3 ' 70.78 133.12 .1104 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Single HSPF:8.5 34.8 kBtu/hr 1 sys#1 12/9/2019 6:18 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPU1 ' MMARY CHECKLIST REPORT, COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 15 34.8 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Carl # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / — Supply — — Return --- Air CFM 25 CFM25 HVAC # V If Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 275 ft' Attic 65 ft' Default Leakage Attic (Default) c(Default) c 1 1 TEMPERATURES Programable� Ceiling Fans: xThermostat:[xj,]Y Heating Jan Feb r[�X]'] Mar Apr [ MMay tX� t I ] Jun `XJ Jult [Xj Aug rX� Oct H Nov [ ] Sep Oct Nov H Dec Dec Venting I 1 Jan I 1 Feb l l l l IRl Mar lhl [ [)Jun f Jul ay I Aug [) Sep Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 76 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (VVEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 6B 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. Oft' Oft 0.3 BEDROOM Default(8lbs/sq.ft. ft' ft 0.3 WIC Defauft(B lbs/sq.ft. ft' ft 0.3 MASTER BATH Defaull(B lbs/sq.ft. ft' ft 0.3 M. BATH Defaull(B lbs/sq.ft. ft' ft 0.3 KITCHEN Default(8 lbs/sq.ft. It, ft 0.3 BATH Default(8 lbs/sq.ft. ft' ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft, ft' ft 0.3 ENTRY Default(8 lbs/sq.ft. ft' ft 0.3 LAUNDRY Default(81bs/sq.ft. ft' ft 0.3 SITTING ROOM Default 81bs/s .ft. ft' ft 0.3 GREAT/DINING 12/9/2019 6:18 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 -AIR BARRIER AND INSULA'. V INSPECTION COMPONENT CRII A TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE DEV GRAND CARLTON SITTING Builder Name: WYNNE DEVELOPEMNT Street: 76 MEDITERRANEAN NORTH Permit Office: ST. LUICE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: 19OM462 Y n Owner: Jurisdiction: ST. LUCIE COIUNTY = Design Location: FL, Fort Pierce c� COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit Insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed, material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed In substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be Insulated. Floors The air barrier shall be Installed at any exposed edge of Insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous Insulation installed on the underside of floor framing and extends from the botto to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on Installation readily conforms to available space shall extend behind piping and Wring. ShowerAub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover Plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 1219/2019 6:20 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX" = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1646 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.040 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.290 c) Area 7c. 138.8 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floortype, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed e. 6 14. Heating system: Capacity 34.8 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 9b. 15. Water heating system 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF 10A1. e) Dedicated heat pump with tank EF_ 10A2. 4.1 f) Heat recovery unit HeatRec% g) Other 10B1. 10B2. 11.0 16. HVAC credits claimed (Performance Method) a) Ceiling fans Yes 11a. 30.0 b) Cross ventilation No 11 b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: I - - . Date: fz - o 9 -/9 Address of New Home: City/FL Zip: FT. PIERCE. FL 1202019 6:18:12 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 61h Edition (2017) Compliant Software Page 1 of 1