HomeMy WebLinkAboutREVISION - BUILDING PERMITOFFICE USE ONLY:
DATE FILED:
REVISION FEE: 7 S
1.
PERMIT #- 1908-0462 a d 0 i
RECEIPT # O I
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-5652
(772) 462-1553 FAV 072) OX-1570
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
LOCATION/S59FEDTI'ERRANEANNORTH
ADDRESS:
2. DETAILED DESCRIPTION OF PROJECT
REVISIONS:
RECEIVED
APR 15 2020
Permitting Department
St. Lucie, County
CHANGE WATER HEATER FROM A 40 GAL. TO A-50 GAL. AND CHANGE TO IMPACT
WINDOWS
3. CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: ST. LICIE COUNTY CERT. #:. 8898
BUSINESS NAME: Corpora on
QUALIFIERS NAMEb South U uI e
ADDRESS: 8l)UU wy 402
CITY: Fort Nt. Lucie STATE: ZIP:
PHONE (DAYTIME): 878-5513-- FAX: 772) 878-7656
4. OWNER/BUILDER INFORMATION:
NAME: Wynn Building Corporation
ADDRESS: Suite402
CITY: STATE:FL
PHONE: (772) 878-5513 FAX:
5.-ARCHITECTBNGINEERINFORMATION:
NAME: BRADEN & BRADEN
ADDRESS: 417 COCUN U fAVE.
CITY: STLT
PHONE (DAYTIME):
Revised 07/22/2014
q1
STATE: FL ZIP: 34996
FAX:
REVISION
FILE COPY
\,: \ VIz�- - U�_\ (O;�_
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
ProjectName: WYNNE DEV GRAND CARLTON SITTING impact BuilderName: WYNNE DEVELOPEMNT
Street: nl\� f\tea - �� � Permit Office: ST. LUICE COUNTY
City,Stale,Zip: FT. PIERCE, FL, PermitNumber:
Owner: Jurisdiction: ST. LUCIE COIUNTY
DesignLocationi FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1., New construction or e)isting. New (From Plans)
9. Wall Types(1571.1 sgft.), Insulation Area
2. Single familyor multiple family Single-family
a. Concrete Block- Int lnsul, Exterior R=4.1 1443.10 ft2
b. Concrete Block -1nl Insul, Adjacent R=11.0 128.00 W
3. Numberof units, if multiple family 1
c. N/A R= ft2
4.Number of Bedrooms 2
d.N/A R= ft2
5. Is this a worst case? Yes
10.Ceiling Types (1646.0 sgft.) Insulation Area
-
a. UnderAttic(Vented) R=30.0 1646.00 ft2
6. Conditioned Floor area above grade (ft2) 1646 _
b. N/A R= f2
Conditioned Floorarea belowgrade(ft2) 0
R=
-
D
11.Ducts
Rs ft2
7. Windows(138.8 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic 6 275
a. U-Factor. Sgl, U=1.04 138.75 ft2
-
SHGC: SHGC=0.29
-
b. U-Factor: N/A ft2
12. Cooling systems kBtu/hr Efficiency
SHGC:
a. Central Unit 34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
d. U-FactSHGCor. NIA
_
13. Hee(abnnrg� systems tu/ E en@@@@����
4.8SHGC: a uV
1
E%rems
Overhang Depth: 2.209 ft.
Area Weighted Average SHGC: 0.290
KKK■■■ddd wWWaaa���r���rrrAreaWeightedAverage
14a t
S. Floor Types (1645.5 sgft.) Insulation Area
a. Electric Cap:50 gallonsEF:
a. Slab -On -Grade Edge Insulation. R=0.0 1645.50 ft2
0.950
b. Conservation features p
b. N/A R= - ft2.
None Gatti D _ 0,
c. N/A R= - ft2
15. Credits CF. Patel
Glass/Floor Area: 0.084 Total Proposed Modified Loads: 53.49"ftVIEWED F L+�+ r/
- ss
Total Baseline Loads: 5 DE COIl I !�/tip�,-f��f-
I hereby that the by
LUCIE COUN /
certify plans and specifications covered
this calculation in the Florida Energy
Review of the plans and �+/v
CC
are compliance with
specifications covered b p
Code.
_62
calculation indicates compliance
with the Florida Energy Code
PREPARED BY:
Before construction is completed
DATE: -
this building will be inspected for t9 - _ y
.
-
compliance with Section 553.908 N �,
I hereby certify that this building, as designed ' mpliance
Florida Statutes. FILE C -
with the Florida Energy Cod
OWNER/AI
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
RECEIVED
APR 1 5 7n?n
Permitting Deperun%r,,
St. Lucie rnpep,.
4/9/20209:49 AM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1. of
(2D21
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Tille: WYNNE DEV GRAND CARLT Bedrooms: 2
Address Type:
Street Address
Building Type: User
ConditionedArea: 1646
Lot#
OwnerName:
Total Stories: 1
Block/Subdivision:
#of Units: 1
Worst Case: Yes
PlatBook:
BuilderName: WYNNE DEVELOPEMNT RotateAngle: 270
Street:
Permit Office: ST. LUICE COUNTY
CrossVentilation: No
County:
St. Lucie
Judsdiction: ST. LUCIE COIUNTY
Whole House Fan: No
City, State, Zip:
Fr. PIERCE,
FamilyType: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
DesignTemp
Int Design Temp Heating
Design DailyTemp
V Designi-ocation
TMYSite 97.5%
2.5%
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1646 15472.4
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 BEDROOM
252 2368.8 No
0
1
1 Yes
Yes
Yes
2 WIC
63 592.2 No
0
1 No
Yes
Yes
3 MASTER BATH
63 592.2 No
0
1 Yes
Yes
Yes
4 M. BATH
56 526.4 No
0
1 Yes
Yes
Yes
5 KITCHEN
192 1804.8 Yes
0
1 No
Yes
Yes
6 BATH
45 423 No
0
1 Yes
Yes
Yes
7 BEDROOM 2
204 1917.6 No
0
1
1. Yes
Yes
Yes
8 ENTRY
61 573 No
0
1 Yes
Yes
Yes
9 LAUNDRY
42 395 No
0
1 Yes
Yes
Yes
10 SITTING ROOM
200 1880 No
0
1 Yes
Yes
Yes
11 GREAT/DINING
468 4399 No
0
1 Yes
Yes
Yes
FLOORS
# FloorType
Space Perimeter PerimeterR-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation
BEDROOM 32ft 0
252 112
----
0 1
0
2 Slab -On -Grade Edge Insulation
WIC 1 ft 0
63 ft2
----
0 1
0
3 Slab-On-GradeEdge Insulation
MASTER BATH 9ft 0
63 ft2
----
0 1
0.
4 Slab -On -Grade Edge Insulation
M.BATH 8ft 0
56 ft2
_---
0 1
0
5 Slab -On -Grade Edge Insulation
KITCHEN 1 ft 0
192 112
----
0 1
0
6 Slab -On -Grade Edge Insulation
BATH 5ft 0
45 ft2
----
0 1.
0
4/9/2020 9:49 AM EnergyGauge® USA 6.0.02 (Rev.1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# FloorType Space Perimeter PerimeterR-Value
Area
JoistR-Value
Tile Wood Carpet
7 Slab-On-GradeEdgelnsulation BEDROOM 31.2ft
0
203.5 ft'
----
0
1
0
8 Slab-On-GradeEdge Insulation ENTRY 7ft
0
61 ft'
--_-
0
1
0
9 Slab-On-GradeEdgelnsulation LAUNDRY Eft
0
42 ft'
_-_-
0
1
0
10Slab-On-Grade Edge Insulation SITTINGROOM 30ft
0
200 ft2
-_-_
0
1
0
11Slab-On-GradeEdge Insulation GREATMINING 25ft
0
468 ft'
----
0
1
0
ROOF
J
Roof
Gable
Roof
Rod
Solar
SA Emitt
Emitt Deck
Pitch
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 GableorShed Metal 1735ft2
274 ft-
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
/
V
# Type Ventilation
Vent Ratio (1 In)
Area
RBS.
IRCC
1 Full attic Vented
300
1646 ft2
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 UnderAttic(Vented) BEDROOM
30
Blown
252 ft2
0.1
Wood
2 UnderAttic(Vented) WIC
30
Blown
63 ft'
0.1
Wood
3 UnderAttic(Vented) MASTER BATH
30
Blown
63 ft'
0.1
Wood
4 UnderAttic(Vented) M..BATH
30
Blown
56 ft'
0.1
Wood
5 UnderAttic(Vented) KITCHEN
30
Blown
192 ft'
0.1
Wood
6 UnderAttic(Vented) BATH
30
Blown
45ft'
0.1
Wood
7 UnderAttic(Vented) BEDROOM
30
Blown
204 ft'
0.1
Wood
8 UnderAtBc(Vented) ENTRY
30
Blown
61 ft'
0.1
Wood
9 UnderAttic(Vented) LAUNDRY
30
Blown
42 ft'
0.1
Wood
10 UnderAtBc(Vented) SITTING ROOM
30
Blown
200 ft2
0.1
Wood
11 UnderAtBc(Vented) GREAT/DINING
30
Blown
468 ft2
0.1
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing Solar
Below
1
NE=>NW Exterior Concrete Block-Int lnsul BEDROOM
4.1 18
0 9
5
169.5 ft2
0
0
0.4
0
2
NW=>S Exterior Concrete Block- Intlnsul BEDROOM
4.1 14
0 9
5
131.8 ft2
0
0
0.4
0
3
NE=>NW Exterior Concrete Block- Int lnsuMASTER BA
4.1 9
0 9
5
84.8 ft2'
0
0
0.4
0
4
NE=>NW Exterior Concrete Block- Intlnsul M.BATH
4.1 8
0 9
5
75.3 ft'
0
0
0.4
0
5
SW=>SE Exterior Concrete Block- Intlnsul BATH
4.1 5
0 9
5
47.1 ft2
0
0
0.4
0
6
NE=>NW Exterior Concrete Block- Int lnsuBEDROOM 2
4.1 1
0 9
5
9.4ft2
0
0.4
0
7
E=>N Exterior Concrete Block- Int lnsuBEDROOM 2
4.1 4
3 9
5
40.0W
0
0
0.4
0
8
SE=>NE Exterior Concrete Block- Int lnsuBEDROOM 2
4.1 10
0 9
5
94.2 ft'
0
0
0.4
0
4/9/2020 9:49 AM EnergyGauge® USA 6.0.02 (Rev. 1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Spam Cavity Width
P
Height
Sheathing Framing Solar Below
o
_9 SW=>SE Exterior Concrete Block- Int lnsuBEDROOM 2 4.1 16 0 9
5 150.7 ft2
01
0 0.4
0
10 NE=>NW Exterior Concrete Block-Int lnsul ENTRY 4.1 1 0 9
5 9.4 ft2
0
0 0.4
0
11 SE=>NE Exterior Concrete Block-Intlnsul ENTRY 4.1 6 0 9
5 56.5 ft2
0
0 0.4
0
12 NE=>NW Exterior Concrete Block- Int lnsul LAUNDRY 4.1 6 0 9
5 56.5 ft2
0
0 0.4
0
13 SW=>SE Exterior Concrete Block- Int lnsuBITTING RO 4.1 10 0 9
5 94.2 ft2
0
0 0.4
0
14 NW=>S Exterior Concrete Block-IntlnsuBITTING RO 4.1 20 0 9
5 188.3 ft2
0
0 0.4
0
15 SW=>SE Exterior Concrete Block -Int lnsuGREAT/DINT 4.1 25 0 9
5 235.4 ft2
0
0 0.4
0
16 N=>W Garage Concrete Block- Int lnsuBEDROOM 2 11 16 8
128.0 ft2
0 0.4
0
DOORS
# Omt DoorType Space Storms
U-Value
Width
Height
Area
Ft
In
Ft In.
1 SE=>NE Wood ENTRY None
-.39 3
1
7
21.6 ft2
2 SW=>SE Insulated SITTING RO None
.39 3
7
21 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
Overhang
V # Omt ID Frame Panes NFRC U-Factor SHGC Imp
Area Depth
Separation
IntShade
Screening
1 NW=>SW2 Metal Low-ESingle Yes 1.04 0.29 Y'
32.9 ft2 1ft51n
1ft5in
Drapes/blinds
Exterior5
2 NE=>NW 4 Metal Low-ESingle Yes 1.04 0.29 Y
6.9 ft2 1 ft 5 in
1 ft 5 in
None
None
3 SE=>NE8 Metal Low-ESingle Yes 1.04 0.29 Y
24.0 ft2 6ft0In
1ft5.in
None
None
_ 4 NW=>SW14 Metal Low-ESingle Yes 1.04 0.29 Y
37.5 ft2 1ft5in
1ft5im
None
None
5 SW=>SE15 Metal Low-ESingle Yes 1.04 0.29 Y
37.5 ft2 tft5in
1ft5 in
None
None
GARAGE
# FloorArea CeilingArea Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
'
1 ' 320 ft2 320 ft2 16 ft
8 ft
11
INFILTRATION
'# Scope Method SLA CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse PmposedACH(50) .000299 1289.3 70.78 133.12 .1104
5
HEATING SYSTEM
# System Type Subtype_ Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split Single HSPF:8.5
34.8 kBtu/hr
1
sys#1
4/9/20209:49 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4of5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow SHR Block
Ducts
1 CentralUnit/
Split
Single SEER: 15
34.8 kBtu/hr
cfm 0.8
1
sys#1
HOT WATER SYSTEM
# System Type
S,bType
Location
EF Cap
Use
SetPnt Conservation
1 Electric
None
Garage
0.95 50 gal
60.9gal
120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
-
Cent # CompanyName
System Model# CollectorModel# Area Volume
FEF
None None
ft2
DUCTS
Supply—
—Return—
Air
CFM25 CFM25
HVAC#
V # .Location R-Value Area
Location
Area LeakageType
Handler
TOT OUT QN
RLF
Heat Cool
1 Attic
6 275 ft2
Attic
65 ft' Defaulti-eakage
Attic
(Default) c(Default) c
1 1
TEMPERATURES
ProgremablerXT,Jhermostat[
Ceiling Fans:
]Y
Heating Jan H Feb
fx]],
N Mar
�[X [D0] Jul
M Aug
4X]� r[X']
Nov
Dec
H
Venting I I Jan (1 Feb
l l
IXl Mar
Apr
May [ Jun [ ]Jul
Aug
(] Sep Oct [ ]X
Nov
Dec
ThermostatSchedule: HERS 2006 Reference
Hours
ScheduleType
1
2 3
4 5 6
7
8 9 10
11
12
Ccoling(WD) AM
78
78 78
78 78 78
78
78 80 80
80
80
PM
80
80 78
78 78 78
78
78 78 78
78
78
Cooling(WEH) AM,
78
78 78
78 78 78
78
78 78 78
78
78
PM
78
78 78
78 78 78
78
78 78 78
78
78
Heating(WD)• AM
66
66 66
66 66 68
68
68 68 68
68
68
PM
68
68 68
68 68 68
68
68 68 68
66
66
Heating(WEH) AM
66
66 66
66 66 68
68
68 68 68
68
68
PM
68
68 68
68 68 68
68
68 68 68
'66
66
MASS
Mass Type
Area
Thickness
FumilureFraction Space
Default(8 lbslsq.fL
0 ft'
0 ft
0.3
BEDROOM
Default(8lbs/sq.ft.
ft2
ft
0.3
WIC
Default(81bs/sq.ft.
ft'
ft
0.3
MASTER BATH
Defaull(8 lbs/sq.ft.
ft2
ft
0.3
M. BATH
Default(81bs/sq.ft.
ft'
ft
0.3
KITCHEN
Default(Blbs/sq.ft.
ft2
ft
0:3
BATH
Defaul48 lbslsq.ft.
ft2
ft
0.3
BEDROOM
Default(81bs/sq.f.
ft2
ft
0.3
ENTRY
Default(Blbs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(81bs/sq.ft.
ft2
ft
0.3
SITTING ROOM
Default 8lbs/s .ft.
ft'
ft
0.3
GREATIDINING
4/9/2020 9:49 AM EnergyGaugeO USA 6.0.02 (Rev. 1)-FlaRes2017FBC 6th Edition (2017) Compliant Software Page 5 of 8
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE DEV GRAND CARLTON SITTING impact Builder Name: WYNNE DEVELOPEMNT
Street, Peroil Office: ST. LUICE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
U
Owner. Jurisdiction: ST. LUCIE COIUNTY
w
Design Location: FL, Fort Pierce
c=i
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access. openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction. of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
•
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall. be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvenled crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
3s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing In exterior walls, or insulation that on
installation readily conforms to available space shall
extend hphond pining grid wiring
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electricallphone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
4/9/2020 9:49 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
.2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home,
1. New home or, addition
1.
New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts
R
6.0
2. Single-family or multiple -family
2.
Single-family
b). Return ducts
R
6.0
c) AMU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system:
Capacity
34.8
a) Split system
SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package
SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1646
d) Room unit/PTAC
EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
1.040
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.290
14. Heating system:
Capacity
34.8
c) Area
7c.
138.8
a) Split system heat pump
HSPF
8.5
b)Single package heat pump HSPF
8. Skylights
c) Electric resistance
COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas
AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG
AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
10A2. 4.1
15. Water heating system
a) Electric resistance EF 0.95
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF_
0 Heat recovery unit HeatRec%o
g) Other
10B1.
1082. 11.0
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
Yes
11a. 30.0
b) Cross ventilation
No
11b.
c) Whole house fan
No
11c.
d) Multizone cooling credit
11d. No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed co compliant features. (�1
Builder Signature: � Dater
Address of New Home: `iS `i�9��` I`\^4^'ti-QC� City/FL Zip: FT. PIERCE. FL
4/9/2020 9:49:31 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017)Compliant Software Page 1 of 1
OFFICE USE ONLY:
DATE FILED-
REVISION FEE:
LOCATION/SITE
ADDRESS:
PERMIT #
RECEIPT #
PLANNING & DEVELOPMENT SERVICES SCANNED
BUILDING & CODE REGULATION DIVISION % LUCIB �'OUIIQI/
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982.5652
(772)462.1553
APPLICATION FOR BUILDING PERMIRRWISIONI
PROJECT INFORMATION
DETAII,ED DESCRIPTION OF PROJECT
REVISIONS:
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #:
BUSINESS NAME:
QUALIFIERS NAME:
ADDRESS:.
CITY:
STATE:
REVIEWED FOR
CODE
�� �COMPLIANCE
ST. LA E (g kQW. #'®LINTY
PHONE (DAYTIME): FAX:
OWNER/BUILDER INFORMATION:
NAME: IL-j )IJ !J !J e- l3 4
ADDRESS: S-� d S c c S 1
CITY: Pam- L STATE:
PHONE (DAYTIME: 77Z 2y I- 8-S' y 3 FAX:
ARCFIITECT/ENGINEER INFORMATION:
TUIU
CITY:
PHONE (DAYTIME):
SLCCC. 9123109
Revised 06130117
STATE:
ZIP:
ZIP: .
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE DEV GRAND CARLTON SITTING
Builder Name: WYNNE DEVELOPEMNT
Street: 78 MEDITERRANEAN NORTH
Permit Office: ST. LUICE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number: 1908-0462
Owner:
Jurisdiction: ST. LUCIE COIUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1571.1 soft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1443.10 ft'
b. Concrete Block - Int Insul, Adjacent
R=11.0 128.00 IF
3. Number of units, If multiple family 1
c. N/A
R= ft'
4. Number of Bedrooms 2
d. N/A
R= ft'
5. Is this a worst case? Yes
10. Ceiling Types (1646.0 soft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1646.00 ft-
6. Conditioned Floor area above grade (ft') 1646
to. N/A
R= ft'
Conditioned floor area below grade (M) 0
c. N/A
R= ft'
11. Ducts
R ft'
7. Windows(138.8 soft.) Description Area
a. Sup: Attic, Rat: Attic, AH: Attic
6 275
a. U-Factor: Sgl, U=1.04 138.75 ft'
SHGC: SHGC=0.29
b. U-Factor: NIA R2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft'
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft'
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 2.692 ft.
Area Weighted Average SHGC: 0.290
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1645.5 soft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 1645.50 ft'
b. Conservation features
b. N/A R= ft`
None
c. N/A R= ft.
15. Credits
CF, Pstat
Glass/Floor Area: 0.084 Total Proposed Modified Loads: 53.15
PASS
Total Baseline
Loads: 53.81
1 hereby certify that the plans and specifications covered by
Review of the plans and
F ($B SrgT
this calculation are in compliance with the Florida Energy
specifications covered by thisO�
Code.
calculation indicates compliance
with the Florida Energy Code.
I: fill n"Cf,
PREPAR
DATE:
Before construction is completed
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
!,)
with the Florida Energy Code.
COp WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE: o-45P
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
12/9/2019 6:20 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R40'5-2017 INPUT' AMARY CHECKLIST REPORT
PROJECT
Title: WYNNE DEV GRAND CARLT
Bedrooms:
2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1646
Lot #
Owner Name:
Total Stories:
1
Block/Subdivision:
# of Units: 1
Worst Case:
Yes
PlatBook:
Builder Name: WYNNE DEVELOPEMNT
Rotate Angle:
270
Street:
Permit Office: ST. LUICE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: ST. LUCIE COIUNTY
Whole House Fan: No
City, Stale, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI
39
90
70
75 299
62
Low
BLOCKS
Number Name Area
Volume
1 Entire House IBM
15472.4
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 BEDROOM 252
2368.8
No
0
1
1 Yes
Yes
Yes
2 WIC 63
592.2
No
0
1 No
Yes
Yes
3 MASTER BATH 63
592.2
No
0
1- Yes
Yes
Yes
4 M. BATH 56
526.4
No
0
1 Yes
Yes
Yes
5 KITCHEN 192
1804.8
Yes
0
1 No
Yes
Yes
6 BATH 45
423
No
0
1 Yes
Yes
Yes
7 BEDROOM 2 204
1917.6
No
0
1
1 Yes
Yes
Yes
8 ENTRY 61
573
No
0
1 Yes
Yes
Yes
9 LAUNDRY 42
395
No
0
1 Yes
Yes
Yes
10 SITTING ROOM 200
1880
No
0
1 Yes
Yes
Yes
11 GREAT/DINING 468
4399
No
0
1 Yes
Yes
Yes
FLOORS
# Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation BEDROOM 32 ft
0
252 ft'
----
0 1
0
2Slab-On-Grade Edge Insulation WIC 1ft
0
63ft'
----
0 1
0
381ab-On-Grade Edge Insulation MASTER
BATH 9 ft
0
63 ft'
----
0 1
0
4SIab-On-Grade Edge Insulation M. BATH 8 ft
0
56 ft'
----
0 1
0
5 Slab -On -Grade Edge Insulation KITCHEN 1 ft
0
192 ft'
---_
0 1
0
6 Slab -On -Grade Edge Insulation BATH 5 ft
0
45 ft'
----
0 1
0
12/9/2019 6:18 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPU1:' -'IMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
7 Slab -On -Grade Edge Insulation BEDROOM 2 31.2 ft
0
203.5 ft-
----
0
1
0
8 Slab -On -Grade Edge Insulation ENTRY 7 ft
0
61 ft'
----
0
1
0
9 Slab -On -Grade Edge Insulation LAUNDRY Eft
0
42 ft'
----
0
1
0
10SIab-On-Grade Edge Insulation SITTING ROOM 30 ft
0
200 ft'
----
0
1
0
11Slab-On-Grade Edge Insulation GREAT/DINING 25 ft
0
468 ft'
----
0
1
0
ROOF
/
Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
V
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Gable or Shed Metal 1735 ft'
274 ft'
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
/
V
# Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
300
1646 ft'
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Free
Truss Type
1 Under Attic (Vented) BEDROOM
30
Blown
252 ft'
0.1
Wood
_
2 Under Attic (Vented) WIC
30
Blown
63 ft'
0.1
Wood
3 Under Attic (Vented) MASTER BATH
30
Blown
63 ft'
0.1
Wood
4 Under Attic (Vented) M.BATH
30
Blown
56 ft-
0.1
Wood
5 Under Attic (Vented) KITCHEN
30
Blown
192 ft-
0.1
Wood
6 Under Attic (Vented) BATH
30
Blown
45 ft'
0.1
Wood
7 Under Attic (Vented) BEDROOM
30
Blown
204 ft'
0.1
Wood
8 Under Attic (Vented) ENTRY
30
Blown
61 ft'
0.1
Wood
9 Under Attic (Vented) LAUNDRY
30
Blown
42 ft'
0.1
Wood
_
10 Under Attic (Vented) SITTING ROOM
30
Blown
200 ft'
0.1
Wood
11 Under Attic (Vented) GREAT/DINING
30
Blown
468 ft'
0.1
Wood
WALLS
Adjacent Space Cavity Width
()Mt Tn Wall Type
Height
Sheathing Framing Solar
Below
_ 1
NE=>NW Exterior Concrete Block- Int lnsulBEDROOM
4.1 18
0 9
5
169.5 ft'
0
0
0.4
0
_ 2
NW=>S Exterior Concrete Block- Int Insul BEDROOM
4.1 14
0 9
5
131.8 ft'
0
0
0.4
0
_ 3
NE=>NW Exterior Concrete Block- Int InsuMASTER BA
4.1 9
0 9
5
84.8 ft'
0
0
0.4
0
_ 4
NE=>NW Exterior Concrete Block - Int Insul M. BATH
4.1 8
0 9
5
75.3 ft'
0
0
0.4
0
_ 5
SW=>SE Exterior Concrete Block -Int Insul BATH
4.1 5
0 9
5
47.1 ft'
0
0
0.4
0
_ 6
NE=>NW Exterior Concrete Block - Int InsuBEOROOM 2
4.1 1
0 9
5
9.4 R'
0
0
0.4
0
7
E=>N Exterior Concrete Block - Int InsuBEDROOM 2
4.1 4
3 9
5
40.0 ft'
0
0
0.4
0
8
SE=>NE Exterior Concrete Block- Int InsuBEDROOM 2
4A 10
0 9
5
94.2 ft'
0
0
0.4
0
12/9/2019 6:18 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017
INPUT: \ MMARY CHECKLIST REPORT
WALLS
Adjacent Space
P
Cavity Width Height
_ e- Ft In Ft In
Area
Sheathing Framing Solar
R_Val
Below
_ 9 SW=>SE Exterior Concrete Block - Int InsuBEDROOM 2
4.1 16 0 9
5
150.7 ft-
0
0 0.4
0
10 NE=>NW Exterior Concrete Block-Intlnsul ENTRY
4.1 1 0 9
5
9.4 ft'
0
0 0.4
0
_ 11 SE=>NE Exterior Concrete Block- Int Insul ENTRY
4.1 6 0 9
5
56.5 R'
0
0 0.4
0
_ 12 NE=>NW Exterior Concrete Block- Int Insul LAUNDRY
4.1 6 0 9
5
56.5 ft'
0
0 0.4
0
_ 13 SW=>SE Exterior Concrete Block- Int InsuBITTING RO
4.1 10 0 9
5
94.2 ft'
0
0 0.4
0
_ 14 NW=>S Exterior Concrete Block- Int Insu61TTING RO
4.1 20 0 9
5
188.3 ft°
0
0 0.4
0
_ 15 SW=>SE Exterior Concrete Block- Int InsuGREAT/DINI
4.1 25 0 9
5
235.4 ft-
0
0 0.4
0
16 N=>W Garage Concrete Block- Int InsuBEDROOM 2
11 16 S
128.0 ft-
0 0.4
0
DOORS
# Omt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 SE=>NE Wood ENTRY
None
.39
3
1
7
21.6 112
2 SW=>SE Insulated SITTING RO
None
.39
3
7
21 ft'
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
_ / Wall
Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1 NW=>SW 2 Metal Low-E Single Yes
1.04 0.29 N
32.9 ft'
2 ft 0 in
1 R 5 In
Drapes/blinds
Exterior 5
_ 2 NE=>NW 4 Metal Low-E Single Yes
1.04 0.29 N
6.9 ft'
2 It 0 in
1 R 5 in
None
None
3 SE=>NE S Metal Low-E Single Yes
1.04 0.29 N
24.0 ft'
6 It 0 in
1 ft 5 in
None
None
4 NW=>SW14 Metal Low-E Single Yes
1.04 0.29 N
37.5 ft'
2 ft 0 in
1 ft 5 in
None
None
5 SW=>SE 15 Metal Low-E Single Yes
1.04 0.29 N
37.5 ft'
2 ft 0 In
1 ft5 In
None
None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 320 ft' 320 ft>
16 ft
8 ft
11
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000299 1289.3 ' 70.78 133.12
.1104
5
HEATING SYSTEM
# System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split
Single HSPF:8.5
34.8 kBtu/hr
1
sys#1
12/9/2019 6:18 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPU1 ' MMARY CHECKLIST REPORT,
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow SHR Block
Ducts
1 Central Unit/
Split
Single SEER: 15
34.8 kBtu/hr
cfm 0.8 1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt Conservation
1 Electric
None
Garage
0.95 40 gal
60.9 gal
120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Carl # Company Name
System Model # Collector Model # Area Volume
FEF
None None
ft'
DUCTS
/ — Supply —
— Return ---
Air
CFM 25 CFM25
HVAC #
V If Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT ON RLF
Heat Cool
1 Attic
6 275 ft'
Attic
65 ft' Default Leakage
Attic
(Default) c(Default) c
1 1
TEMPERATURES
Programable�
Ceiling Fans:
xThermostat:[xj,]Y
Heating Jan Feb
r[�X]']
Mar
Apr
[ MMay tX� t
I ] Jun `XJ Jult
[Xj Aug
rX� Oct H Nov
[ ] Sep Oct Nov
H Dec
Dec
Venting I 1 Jan I 1 Feb
l l l l
IRl Mar
lhl
[ [)Jun f Jul
ay
I Aug
[) Sep
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8 9 10 11
12
Cooling (WD) AM
78
76 78
78 78 78
78
78 80 80 80
80
PM
80
80 78
78 78 78
78
78 78 78 78
78
Cooling (VVEH) AM
78
78 78
78 78 78
78
78 78 78 78
78
PM
78
78 78
78 78 78
78
78 78 78 78
78
Heating (WD) AM
66
66 66
66 66 68
68
68 68 68 68
68
PM
68
68 6B
68 68 68
68
68 68 68 66
66
Heating (WEH) AM
66
66 66
66 66 68
68
68 68 68 68
68
PM
68
68 68
68 68 68
68
68 68 68 66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction Space
Default(8 lbs/sq.ft.
Oft'
Oft
0.3
BEDROOM
Default(8lbs/sq.ft.
ft'
ft
0.3
WIC
Defauft(B lbs/sq.ft.
ft'
ft
0.3
MASTER BATH
Defaull(B lbs/sq.ft.
ft'
ft
0.3
M. BATH
Defaull(B lbs/sq.ft.
ft'
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
It,
ft
0.3
BATH
Default(8 lbs/sq.ft.
ft'
ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft,
ft'
ft
0.3
ENTRY
Default(8 lbs/sq.ft.
ft'
ft
0.3
LAUNDRY
Default(81bs/sq.ft.
ft'
ft
0.3
SITTING ROOM
Default 81bs/s .ft.
ft'
ft
0.3
GREAT/DINING
12/9/2019 6:18 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 -AIR BARRIER AND INSULA'. V INSPECTION COMPONENT CRII A
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE DEV GRAND CARLTON SITTING Builder Name: WYNNE DEVELOPEMNT
Street: 76 MEDITERRANEAN NORTH Permit Office: ST. LUICE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number: 19OM462
Y
n
Owner: Jurisdiction: ST. LUCIE COIUNTY
=
Design Location: FL, Fort Pierce
c�
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
Insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed,
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed In substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be Insulated.
Floors
The air barrier shall be Installed at any exposed edge of Insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous Insulation installed on the
underside of floor framing and extends from the botto
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring a
plumbing in exterior walls, or insulation that on
Installation readily conforms to available space shall
extend behind piping and Wring.
ShowerAub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover Plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
1219/2019 6:20 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX" = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0
c) AHU location Attic
3. No. of units (if multiple -family) 3. 1
4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8
a) Split system SEER 15.0
5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.) 6. 1646 d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average) 7a. 1.040
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.290
c) Area 7c. 138.8
8. Skylights
a) U-factor:(weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. Floortype, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
e. 6
14. Heating system: Capacity 34.8
a) Split system heat pump HSPF 8.5
b) Single package heat pump HSPF
c) Electric resistance COP
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
9b.
15. Water heating system
9c.
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
10A1.
e) Dedicated heat pump with tank EF_
10A2.
4.1
f) Heat recovery unit HeatRec%
g) Other
10B1.
10B2.
11.0
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
Yes
11a.
30.0
b) Cross ventilation
No
11 b.
c) Whole house fan
No
11c.
d) Multizone cooling credit
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: I - - . Date: fz - o 9 -/9
Address of New Home:
City/FL Zip: FT. PIERCE. FL
1202019 6:18:12 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 61h Edition (2017) Compliant Software Page 1 of 1