HomeMy WebLinkAboutGENERATOR PAPERWORK16/20/22 kW
INCLUDES:
• True Power- Electrical Technology
• Two Line LCD Multilingual Digital
Evolution'" Controller(English/Spanish/
French/Portuguese)
• Two Transfer Switch Options Available:
100 Amp, 16 Circuit Switch or
200 Amp Service Rated Smart Switch.
See Page 5 for Details.
• Electronic Governor
• Standard wi-Fi- Remote Monitoring
• System Status & Maintenance Interval LED Indicators
• Sound Attenuated Enclosure
• Flexible Fuel Line Connector
• Direct -To -Dirt Composite Mounting Pad
• Natural Gas or LP Gas Operation
• 5 Year Limited Warranty
,
E1 1
SCANNED
BY
St. LuCieCOUnty
• Listed and Labeled by the Southwest Research Institute allowing
installation as close as 18' (457 mm) to a structure.*
*Must be located away from doors, windows, and fresh air
intakes and in accordance with local codes.
https:l/assets.swri.orrg9llibrary/DirWoryOfListedPmduwI
ConsoucUonlndustryl973 DOC 204_13204-01-01 Rao9.Pdt
FEATURES
O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's O
success In providing the most reliable generators possible. Generac's G-Force engine
lineup offers added peace of mind and reliability for when you need It the most. The
G-Force series engines are purpose built and designed to handle the rigors of
extended ran times In high temperatures and eedreme operating conditions.
O TRUE POWER- ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O
form produce less than 5%Total Harmonic Distention for utility quality power. This allows
confident operation of sensitive electronic equipment and micro -chip based appliances,
such as variable speed HVAC systems.
GENERAC®
GUARDIAN° SERIES
Residential Standby Generators
Air -Cooled Gas Engine
Standby Power Rating
Models G007036-1, G007037-1 (Aluminum - Bisque) -16 kW 60 Hz
Model G007035-1 (Aluminum - Bisque) -16 kW 60 Hz
Models G007039-1, G007038-1 (Aluminum - Bisque) - 20 kW 60 Hz
Models G007043-2, GOD7042-2 (Aluminum - Bisque) - 22 kW 60 Hz
CV`USQ I'�
LISTED `�((J u"�'u,' 7
Note: CUL cedification only applies to unbundled units and units packaged with
limited circuit switches. Units packaged with the Smart SwIch are UL cemtied in
the USA only.
SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION:
This slate -of -the -art power maximizing regulation system is standard on
all Generac models. It provides optimized FAST RESPONSE to changing
load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
electronically torque -matching the surge loads to the engine. Digital
voltage regulation at ±1 %.
SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer
network provides parts and service know-how for the entire unit, from the
engine to the smallest electronic component.
O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are
J PROTOTYPE TESTED J NEMA MGI.22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this
J SYSTEM TORSIONAL TESTED J MOTOR STARTING ABILITY confidence is that the GENERAC product line Includes its own transfer
systems and controls for total system compatibility.
O MOBILE LINK" REMOTE MONITORING: FREE with every Guardian Series Home w GENERAC „•�.
standby generator. Allows you to monitor the status of your generator from anywhere in the ~I ®O €w c rr�r..
world using a smailpfrone, tatilet, o7 PC: Easily access -information sock aslhe cuuenl P R 0 M I S E M. iM +Il�r4fV�1rJ
operating status and maintenance alerts. Connect your account to your authorized service
dealer far fast, friendly and proactive service. With Mobile Link you are taken care of before
the need power outage.
GENERACO
16/20/22
W
features and benefits
Engine
•
Generac G-Force design
Maximizes engine"breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly
rings helps the engine run cooler, reducing oil consumption resulting in longer engine life.
•
"Spiny-lok" cast iron cylinder walls
Rigid construction and added durability provide long engine life.
•
Electronic ignition/spark advance
These features combine to assure smooth, quick starting every time.
•
Full pressure lubrication system
Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine
life. Now featuring up to a 2 year/200 hour oil change interval.
•
Low oil pressure shutdown system
Shutdown protection prevents catastrophic engine damage due to low oil.
•
High temperature shutdown
Prevents damage due to overheating.
Generator
•
Revolving field
Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature
generator.
•
Skewed stator
Produces a smooth output waveform for compatibility with electronic equipment.
•
Displaced phase excitation
Maximizes motor starting capability.
•
Automatic voltage regulation
Regulates the output voltage tot 1% prevents damaging voltage spikes.
•
UL2200listed
For your safety.
Transfer Switch (if applicable)
•
Fully automatic
Transfers your vital electrical loads to the energized source of power.
•
NEMA 3R
Can be Installed inside or outside for maximum flexibility.
•
Remote mounting
Mounts near your existing distribution panel for simple, law -cost installation.
Evolution— Controls
•
Auto/Manual/Off Illuminated buttons
Selects the operating mode and provides easy, at -a -glance status Indication in any condition.
•
Two-line LCD multilingual display
Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences.
•
Sealed, raised buttons
Smooth, weather -resistant user interface for programming and operations.
•
Utility voltage sensing
Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage.
•
Generator voltage sensing
Constantly monitors generator voltage to ensure the cleanest power delivered to the home.
•
Utility interrupt delay
Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of
five (5) seconds by a qualified dealer.
•
Engine warm-up
Ensures engine is ready to assume the load, setpoint approximately 5 seconds.
•
Engine cool -down
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
•
Programmable exercise
Operates engine to prevent oil seal drying and damage between power outages by funning the generator
for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing
flexibility and potentially lower fuel costs to the owner.
•
Smart battery charger
Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM -style batteries.
•
Main line circuit breaker
Protects generator from overload.
•
Electronic governor
Maintains constant 60 Hz frequency.
Unit
•
SAE weather protective enclosure
Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding
winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine
maintenance items. Electrostatically applied textured epoxy paint for added durability.
•
Enclosed critical grade muffler
Quiet, critical grade muffler is mounted inside the unit to prevent Injuries.
•
Small, compact, attractive
Makes for an easy, eye appealing installation, as close as 18' (457 mm) away from a building.
16/20/22 W
GENERAC®
features and benefits
Installation System
• 1 it (305 mm) flexible fuel line connector
Absorbs any generator vibration when connected to rigid pipe.
• Direct -to -dirt composite mounting pad
Complex lattice design prevents settling or sinking of the generator system.
• Integral sediment Vap
Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life.
Remote Monitoring
• Ability to view generator status
Monitor your generator via your smadphone, tablet, or computer at any time via the Mobile Link application for
complete peace of mind
• Ability to view generator Exercise/Run and Total Hours
Review the generator's complete protection profile for exercise hours and Iola] hours
• Ability to view generator maintenance information
Provides maintenance information for your specific model generator when scheduled maintenance is due
• Monthly report with previous month's activity.
Detailed monthly reports provide historical generator information
• Ability to view generator battery information
Built in battery diagnostics displaying current stale of the battery
• Weather information
Provides detailed local ambient weather conditions for generator location
Ila
GENERACr
16/20/22 kW � : specifications
Generator
Model G007035.1, G0070364, 00070384, G0070394 G007042.2, 0007043-2
LRatea AC_Frequency _ _ _ _ _ _ _ QTiz 60Hi —60H
Power Factor 1.0 1.0 1.0
Type of Engine GENERAL G-Force 1000 Series
[Compression B2do 951 _ _ 9.51 0.5i.
Starter 12 VDC 12 VDC 12 VDC
Os/hr (m3yhr)
1/2 Load 218 (6.17)
Full Load 309 (8.75)
It" Ar (9aVhr) [I/hr]
112 Load 74 (2.03) [7.7
204 (5.78)
301 (8.52)
87 (2.37) [8.9
228 (6.46)
327 (9.26)
92 (2.53) [9:
must be shed for full load. Required Nat pressure to prun"m fuel inlet at all load ranges -3.5-T water column (7-13 mm mercury) for natural gas, 10-12'waater column (19-22 mm mercury)
TU content, multiply Oyler 2500(LP)or Porx1000INS). For Megaloule content multiply ms/hror 93.15(LP) or ms/hrx 37.26(NG)
"Sowtl Ievdsamtom in Me her ofthegenvamcSound users low homoihershesoflye geserelormaythehigher depending onim¢I6llonparameters. Romig defrulom-SWW.Appawbleforsuppryingemegencypoxerfortheduncon
ofthe WGly power outage. No merkad minusiaty is erdlal forfha ming. (M ounce In acmrdanmwM B55514, 603046 end D046271).' 1daXImum IdImmltmnps she omenl are 9A1eGio end funned byNdltactors as MI BlWmegaloule
conlentalMleNl¢mpe26ue, alghak, mpme powarand mndNm. etc Neuman power deneasesabmA 35 percedforemh1,000 hot(3048 meIons)abouesea[mi.antlaWMlldeuease about l pencerd for each VC(1 D-0 abore 16-0(60 T.
GENERAC'
16/20/22 kW switch options
Limited Circuits Switch Features
• 16 space, 24 circuit, breakers not included.
• Electrically operated, mechanically -held contacts for fast, positive
connections
• Rated for all classes of load,100% equipment rated, both inductive and
resistive.
• 2-pale, 250 VAC contactors.
• 30 millisecond transfer time. -
• Dual coil design.
• Rated for both capper and aluminum conductors.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEM VUL 3R aluminum outdoor enclosure allows for indoor or outdoor
mounting flexibility.
• Multi listed for use with 1'standard, tandem, GFCl and AFCI breakers from
Siemens, Murray, Eaton and Square D for the most flexible and cost effective
install.
Dimensions
Height
Width
Depth
Hl
H2
Wt
W2
in
26.75
30.1
10.5
13.5
6.91
mm
679A
764.3
266.7
343.0
175A
Wire Ranges
Conductor Lug
Neutral Lug
Ground Lug
1/0-#14
210-#14
2/0-#14
Service Rated Smart Switch Features
• Includes Digital Power Management Technology standard (DPM).
• Intelligently manages up to four air conditioner loads with no additional
hardware.
• Up to four more large (240 VAC) loads can be managed when used in
conjunction with Small Management Modules (SMMs).
• Electrically operated, mechanically -hold contacts for fast, clean connections.
• Rated for all classes of load, 100% equipment rated, both inductive and resis-
tive.
• 2-pale, 250 VAC contactors.
• Service equipment rated, dual coil design.
• Rated for both aluminum and copper conductors.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMAIUL 3R aluminum outdoor enclosure at lows for Indoor or outdoor mount-
Ing flexibility.
Dimensions
200 Amps 120/240, 1e
Open Transition service Rated
Height
Width
Depth
H1
H2
W1
12
In
26.75
30.1
10.5
13.5
6.91
man
679.4
764.3
266.7
343.0
175.4
Model
G0070364 (16kW)
No. of Poles
2
Current Rating (Amps)
100
Vollage Rating (VAC)
120 /240.10
Utillty Voltage Monllor (Rued)'
-Pick-up
a7mpoul
80%
65%
Return to Utllity'
approx.15sec —�
Exercises bi-weekly for 5 minutes'
Standard
UL listed
Standard
Total Circuits Available
24
Tandem Breaker Capabilities
8Undems
Circuit Breaker Protected
Available RMS Symmelncal
Fault Current Q 250 Volts
10,000
*Function of Evolution Controller
Exercise can be set to weekly or monthly
u
Made]
G007037.1 (16 kW)/G007039-1 (20 kW)/
G007043.2 (22 kW)
No. of Poles
2
Current Rating (Amps)
200
Vollage Rating (VAC)
1201240,10
U611tyVoltage Monitor (Feed)'
-Pick-up
-Dropoul
80%
65%
Return to U01ity'
ap_prox 13 sec
Exercises bi-weekly for 5 minutes'
Standard
UL Listed
Standard
Enclosure Type
NEMA/UL 3R
Circuit Breaker Protected
_ 22,000
Lug Range
250 MCM -#6
*Function of Evolution Controller
Exercise can be set to weekly or monthly
N
c
0
N
T
5of6
16/20/22 kW
GENERAC
available accessories
Model # Product Description
The WI-F enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Mon-
G007005.0
Wf-Fi LP Fuel Level Monitor
itoring the LP tanks fuel level Is an important step In making sure your generator is ready to run during an
unexpected power failure. Status alerts are available through a free application to notify when your LP tank
is in need of a refill.
G005819-0
26R Wet Cell Battery
Every standby generator requires a batteryto start the system. Generac offers the recommended 26R wet
cell battery for use with all air-cooled standby product (excluding PowerPact®).
G007101-0
Battery Pad Wanner
The pad warmer rests under the battery. Recommended for use itthe temperature regularlyfalls below
0 °F (-18'Q. (Nat necessary for use with AGM -style batteries).
G007102-0
Oil Warmer
Oil warmer slips directly overthe oil filter. Recommended for use if the temperature regularly falls below 0 *F
(-18 -C).
G007103-1
Breather Warmer
The breather wanner is for use in extreme cold weather applications. For use with Evolution controllers
only in climates where heavy Icing occurs.
G005621-0
Amdliary Transfer Switch
The awdliary transfer switch contact ldt allows the transfer switch to lock out a single large electrical load
Contact Kit
you may not need. Not compatible with 50 amp pre -wired switches.
Fascia Base Wrap Kit
The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a
G007027-0-Bisque
(Standard on 22 kW)
sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting
holes located in the base.
If the generator enclosure is scratched or damaged, it is important to touch up the paint to protect from
G005703-0 -Bisque
Paint Kit
future corrosion. The paint kit Includes the necessary paint to property maintain or touch up a generator
enclosure.
G006485-0
Scheduled Maintenance Kit
Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine
maintenance on a Generac automatic standby generator.
Smart Management Module
Smart Management Modules are used in conjunction with the Automatic Transfer Switch to Increase its
G006873-0
(50 Amps)
power management capabilities. it provides additional power management flexibility net found in any other
power management system.
dimensions & UPCs
Dimensions shown areappro dmate. Refer to Inslallallm manual for coacte imensions. DO NOTLISETHESE DIMENSIONS FOR INSTALLATION PURPOSES.
LEPTSIOE VIEW
pe.s NI
FROMVIEW
Model
UPC
G007035-1
696471074161
G007036-1
696471074154
G007037-1
696471074178
G007038-1
696471074185
G007039-1
696471074192
G007042-2
696471074208
G007043-2
696471074215
GENE RAC® Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com
@2018 GenemePower Systems, Ire. All dgms resewed. All specl<calons are sub;•ed to change wetout notice. Pon No. 10000000194-H (0/01/18)