HomeMy WebLinkAboutLOAD CALULATIONOptional Load Calculation
Heat Larger Than Air
L V L✓ SF x 3VA Living Only
(2) Small appliance ckts @ 1500VA each
Refrigerator @ 1500
Refrigerator @ 1500
Freezer @ 1500
Washing machine @ 1500
Dishwasher @ 1500
Disposal @ 1500
Mini Sewer @ 15.00
Clothes Dryer @ 5000
Range @ 12000 00)ft-OvPe\
Water heater @ 4500
Fixed microwave @ 1500
Vacuum @ 1500
Trash Compactor @ 1500
Pool Heater@'nameplate' .
Spa @ `name plate'
Motors 746VA per HP
Garage Door Opener
FILE COPY
1) Total
2) First 10 KVA of general load @ 100%
3) Subtract One 2 from 1
4) Multiply line 3 @ 40%
5) Add lines 2 and 4
6) 60/50amp breaker for heat (10000)
7) 40/30amp breaker for heat (500D)
E) Total heat- Add lines 6 and 7
9) Multiply line S @ 65%
10) Add lines 5 and 9
11) Divide line 10 by240
Summary:
Line 10 is the total KW
Line 11 is the total Amps
17`6
BY
St. Lucie COun4V
STILICIE COUNTY
PLAN REVIEW
SLOG:
DATE:
ELE
DATE:wr
PLUMB:
DATE:
MECH:
DATE:
f eenamtor Size Needed)
(Breaker Size Needed)