HomeMy WebLinkAboutT B S ENGINEERING ENGINEERING PAPERWORKRECEIVED AUG 2 8 119 ST. Lude County, Permitting TUBULAR. 13UIL611y a SYSTEM,5' to STRUCTURAL DESIGN ENCLOSED BUILDING EXPOSURE E la'Jtl'iXIMCJM 30'-099WIDE X 2��'Yi+Rr�M 0'-079 E'1-gyJ-[y` pHEIGHT- BOX EAW E F AND BOW FRAME 18 December 2017 Revision 4 M&A Project No.16022S/17300S Prepared for: Tubular Building Systems, LLC 631 SE Industrial Circle Lake City, Florida 32025 Prepared by: h COPS' ()'FOR PLIANCE wry — ST, LUCIE COUNTY Moore and Associates Engineering and Consulting, Inc. gOCC 1009 East Avenue North Augusta, SC 29841 401 S. Main Street, Suite 200 Mount Airy, NC 27030 MOORE AND ASSOCIATES ENUtNtrRINO ANC) CONSULTIVE t Florida Product Approval Codes Roll -Up Doors: Janus International Corporation Model 750: 21450.8 Walk -In Door: Elixir Door & Metal Company blank (no window): 17996.5 Window: Kinro 993.7 EXP 10/19/21 Roof Deck: Capital Metal Supply Inc. Ag Panel: 20147.1 Wall Panel: Capital Metal Supply Inc. Ag Panel: 20148.1 EXP 12/31/2019 EXP 9/14/2020 EXP 07/20/2020 EXP 07/20/2020 If you have any questions on concern, please contact Donald Little at 386-961-0006 or at tubularbuildingsystems@gmail.com. S.�0''% .., .�P,. �� G E N SF •.; 9�i.�, .. No 57170 S PR152011 ITATE OF :WW NA1.��;.``• MOORE AND ASSOCIATES DRAVN BY. LT TUBULAR BUILD YSTEMS ENGINEERING AND CONSULTING, INC. CHECKED BY. PON 30'-0"x20W' ENCLOSED BUILDING EXP. B PE SEAL COVER SHEET PROJECT Mm VSN DATE. 12-18-17 SCALE. NTS 16o22S�I173005 THIS DOCUMENT IS THE PRDPERTT W 14002E AND ASSOCIATES ENGINEERING AND ENTEISUiTRIICCTEYZPRO THITDOCI IBBITED ANO ]WqINGENONTTARE1PON HAY BE SUWECT TO LEGAL ACTIIX T. 1 DVEi ND SK-3 Va 4 CLIENT, TBS k DRAWING INDEX SHEET 1 PE SEAL COVER SHEET SHEET 2 DRAWING INDEX SHEET 3 INSTALLATION NOTES AND SPECIFICATIONS SHEET 4 TYPICAL SIDE AND END ELEVATIONS SHEET 5 TYPICAL RAFTER COLUMN END AND SIDE FRAMING SECTIONS (BOX EAVE RAFTER) SHEET 6A TYPICAL RAFTER COLUMN CONNECTION DETAILS (LACED COLUMN) SHEET 6B TYPICAL RAFTER COLUMN CONNECTION DETAILS (DOUBLE COLUMN) SHEET 6C TYPICAL RAFTER COLUMN CONNECTION DETAILS (SINGLE COLUMN) SHEET 7 TYPICAL RAFTER COLUMN END AND SIDE FRAMING SECTIONS (BOW RAFTER) SHEET BA TYPICAL RAFTER COLUMN CONNECTION DETAILS (DOUBLE COLUMN) SHEET 8B TYPICAL RAFTER COLUMN CONNECTION DETAILS (SINGLE COLUMN) SHEET 9A BASE RAIL ANCHORAGE ❑PTIONS SHEET 9B ❑PTIONAL FOUNDATION ANCHORAGE SHEET 10 TYPICAL END WALL AND SIDE WALL ❑PENING FRAMING SECTIONS (BOX EAVE RAFTER) SHEET 11 TYPICAL END WALL AND SIDE WALL ❑PENING FRAMING SECTIONS (BOW RAFTER) SHEET 12 WALL OPENING DETAILS SHEET 13 LEAN-TO ❑PTIONS (BOX EAVE RAFTER) SHEET 14 LEAN-TO ❑PTIONS (BOW RAFTER) SHEET 15 VERTICAL ROOF/SIDING ❑PTION END AND SIDE 'ELEVATION AND SECTION SHEET 16 ❑PTIONAL DOOR HEADER MOORE AND ASSOCIATES I DRAWN By, LT TUBULAR BUILDING SYSTEMS ENGINEERING AND CONSULTING, INC. CHECKED BY, PDH 30Wx20o 0" ENCLOSED BUILDING EXp. B a JDW& ND SK-3 �EWJ 4 INSTALLATION NOTES AND SPECIFICATIONS 1. DESIGN 1S FOR A MAXIMUM 30'-0' WIDE x 20'-0' EAVE HEIGHT ENCLOSED STRUCTURES. 2. DESIGN WAS DONE IN ACCORDANCE WITH THE 2017 FLORIDA BUILDING CODE (FBC) GTH EDITION, 2012 INTERNATIONAL BUILDING CODE (IBC), AND 2015 IBC. 3. DESIGN LOADS ARE AS FOLLOWS, A) DEAD LOAD = 1.5 PSF B) LIVE LOAD = 12 PSF C) GROUND SNOW LOAD = 10 PSF 4. LOW ULTIMATE WIND SPEED 105 TO 140 MPH (NOMINAL WIND SPEED 81 TO 108 MPH) MAXIMUM RAFTER/POST AND END POST SPACING = 5.0 FEET. 5. HIGH ULTIMATE WIND SPEED 141 TO 170 MPH (NOMINAL WIND SPEED 109 TO 132 MPH)- MAXIMUM RAFTER/POST AND END POST SPACING = 4.0 FEET. 6. LOW HAZARD RISK CATEGORY I (WIND), 7. WIND EXPOSURE CATEGORY B. 8. SPECIFICATIONS APPLICABLE TO 29 GAUGE METAL PANELS FASTENED DIRECTLY TO 2 1/2' x 2 1/2' — 14 GAUGE TUBE STEEL (TS) FRAMING MEMBERS. FOR VERTICAL PANELS, 29 GAUGE METAL PANELS SHALL BE FASTENED TO 18 GAUGE HAT CHANNELS (UNLESS OTHERWISE NOTED). 9. AVERAGE FASTENER SPACING ON —CENTERS ALONG RAFTERS OR PURLINS, AND POSTS, INTERIOR = 9' OR END = 6', (MAX.) 10. FASTENERS CONSIST OF 012-14x3/4' SELF —DRILLING FASTENER (SDF), USE CONTROL SEAL WASHER WITH EXTERIOR FASTENERS. SPECIFICATIONS APPLICABLE ONLY FOR MEAN ROOF HEIGHT OF 20 FEET OR LESS, AND ROOF SLOPES OF 14' (112 PITCH) OR LESS SPACING REQUIREMENTS FOR OTHER ROOF HEIGHTS AND/OR SLOPES MAY VARY. 11. GROUND ANCHORS SHALL BE INSTALLED THROUGH BASE RAIL WITHIN 6' OF EACH RAFTER COLUMN ALONG SIDES. 12. GROUND ANCHORS (SOIL NAILS) CONSIST OF B4 REBAR W/WEL➢ED NUT x 30' LONG IN SUITABLE SOIL CONDITIONS MAY BE USED FOR LOW ( S 109 MPH NOMINAL) WIND SPEEDS ONLY. OP710MAL ANCHORAGE MAY BE USED IN SUITABLE SOILS AND MUST BE USE IN UNSUITABLE SOILS AS NOTED. 13. OPTIONAL BASE RAIL ANCHORAGE MAY BE USED FOR LOW AND MUST BE USED FOR HIGH WIN➢ SPEEDS. 14, WIND FORCES GOVERN OVER SEISMIC FORCES. SEISMIC PARAMETERS ANALYZED ARE - SOIL SITE'CLASS = ➢ RISK CATEGORY I/II/III R= 3.25 IE= 1.0 S"= 1.522 V= C'w Sop 0.839 MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. TUBULAR BUILDING SYSTEMS 30'-0"x2OW' ENCLOSED BUILDING ENP. B JOB NW SK-3 FEV, 4 ❑ BOX EAVE FRAME RAFTER ENCLOSED BUILDING R➢LL-UP DOOR (AS APPLICABLE) SWINGING DOOR ➢ESILN PRESSURE (AS APPLICABLE) LOW = (IBS PSG. -IDA PSF) ➢ESIGN PRESSURE HIGH (27.95 PSF, -30.7 PSF) LI" 20.B PSF, -22A PSF> HIGH = (3135 PSF, -34.15 PSG) 6' -- MAXIMUM RAFTER SPAN (V) )FLASHING TYPICAL END ELEVATION -HORIZONTAL ROOF SCALE. NTS BOW FRAME RAFTER ENCLOSED BUILDING ROLL -UP DOM (AS APPLICABLE) - rSWINGING DOOR DESIGN PRESSURE APPLICABLE) LOW • [1B5 PSF, -%4 PSF) DE DESIGN PRESSURE HIGH • (27.95 PSF, -30d PSF) LOW = (EBB PSF, -22.6 PSF) �'— HIGH - (31AS PSF. -34.15 PSF) TYPICAL END ELEVATION SCALE, NTS TYPICAL SIDE ELEVATION SCALE. NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. 6' WINDOW (AS APPLICABLE) LPRESSURE LOW OV - (218 PSF, -23.6 PSF) H[GH • 13285 PSF, -35.6 PSF) LENGTH VARIES DEPENDING -ON NUMBER AND SPPCINGOFOF RAFTERS TYPICAL SIDE ELEVATION -HORIZONTAL ROOF SCALE: NTS ��t�yNE S= O''a *:' 0 57170 L R 5 2019?¢ TATE OF , <4 2Qi < c� O R 10 P GN�� TUBULAR BUILDING SYSTEMS 30'-0"x20W" ENCLOSED BUILDING EXP. B 29 GA. GALVANIZED METAL ROOF AND PANELS FASTENED TO RAFTERS AND f 24' IB GA U-CHANNEL BRACE FASTENED TO RAFTER WITH (4) Y12-14x3/4' S➢F'S AT EACH END (B PER BRACE) 29 CA GALVANIZED METAL ROOF PANELS FASTENED TO RAFTERS i 24' IS GA (1-CHANNEL BRACE FASTENED TO RAFTER WITH (4) 112-14v3/4' SDF'S AT EACH END (S PER BRACE) TYPICAL RAFTER/COLUMN END FRAME SECTION TYPICAL RAFTER/COLUMN END FRAME SECTION RrAi r.. NTR Crel r, NTc TYPICAL RAFTER/COLUMN END FRAME SECTION TYPICAL RAFTER/COLUMN SIDE FRAMING SEC SCALE' NTS SCALE, NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. TUBULAR BUILDING SYSTEMS 30W x20W' ENCLOSED BUILDING ENP. B IS ROOF RAFTER 3/IH^\ CONNECTOR ."T SLEEVE TO 3/16 VVV_ RAFTER (TYP) co 6' 3/16 lYP S. 1 � i i S CHORD IS COLUMN BOX EAVE RAFTER COLUMN CONNECTION DETAIL FOR HEIGHTS 16'-0- < TO < 20'-0' SCALE: NTS BRACE SECTION SCALE: NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. GA U-CHANNEL BRACE IS COLIMN HNIHUM 6' LONG, MINMUM IS GA. TS NIPPLE. SECURE WITH (O B12-14x3/4' SDF•S - - 3'H W 3/l6 SL BA IS RINUpUi 4 8 BASEE RAIL RAFTER COLUMN/BASE RAIL CONNECTION DETAIL L" SCALE: NTS TUBULAR BUILDING SYSTEMS 30'-0" x20W' ENCLOSED BUILDING EXP. B DATE. 1 -18-17 SCALEv NTS 1G022S/I73WS 7. 6A OVG. ND SK-3 6EV, 4 q BOX EAVE RAFTER COLUMN CONNECTION DETAIL FOR HEIGHTS 14'-0- < TO < 16'-0- i SCALES NTS BRACE SECTION SCALE: NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. RAFTER COLUMN/BASE RAIL / `CONNECTION DETAIL SCALE- NTS -3 170 5 201 OF . TUBULAR BUILDING SYSTEMS X-0"x20'-0" ENCLOSED BUILDING EXP. B NM SK-3 BOX EAVE RAFTER COLUMN CONNECTION DETAIL ;A FOR HEIGHTS 10'-0' < T❑ < 14'-0' SCALE, NTS COLUMN SLEEVE SASE RAIL / 3/I6 SDF'S RAFTER COLUMN/BASE RAIL 1got! NECTION DETAIL 1- SCALES NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. TS ROOF CONNECTOR 3/I6 SLEEVE 2 TO RAFTER 3/16 i HININIM 6' LONG•- HINIMUH IS CAN TS NIPPLE. SECURE POST TO NIPPLE VITH f0 ZIR-I4x3/4• SDF•S GA.. U-CHANNEL. BRACE BOX EAVE RAFTER COLUMN CONNECTION DETAIL FOR HEIGHTS < 10'-0' 1 u SCALES NTS BRACE SECTION SCALE. NTS TUBULAR BUILDING SYSTEMS 30'-0'k20W' ENCLOSED BUILDING EXP.B tsozzsn7al NM SK-3 V., 29 GA. GALVANIZED METAL ROOF PANELS FASTENED TO RAFTERS I a Q) 24' IB 6A U-CHANNEL BRACE FASTENED TO RAFTER WITH (4) 912-14x3/4' SDF'S AT EACH END (B PER BRACE) 29 GA. GALVANIZED METAL ROOF PANELS FASTENED TO RAFTERS 24' IS GA. V-CHANNEL BRACE FASTENED TO RAFTER WITH (41 412-14x3/4' SOPS AT EACH ENO (B PER BRACE) TYPICAL RAFTER/COLUMN END FRAME SECTION TYPICAL RAFTER/COLUMN END FRAME SECTION SCALE. NTS SCALE: NTS SEE NOTES (SHEET 3) FOR MA%IMIM TYPICAL RAFTER/COLUMN SIDE FRAMING SECTION SCALE. NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. TUBULAR BUILDING SYSTEMS 30'4 x20' 0" ENCLOSED BUILDING EXP. B BOX EAVE RAFTER COLUMN CONNECTION DETAIL FOR HEIGHTS W-0- < TO < 16'-0' i SCALE: NTS BRACE C12-14s3/4' 2 1/2' END [B PER BRACE SECTION SCALE: NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. DOUBLE COLUMN :aF CRAFTER COLUMN/BASE RAIL ONNECTION DETAIL E" SCALE. NTS TUBULAR BUILDING SYSTEMS 30'4'x20'-0" ENCLOSED BUILDING EXP. B NU ND SK-3 BOX EAVE RAFTER COLUMN CONNECTION DETAIL FOR HEIGHTS 10'-0' C TO C W-0' SCALE NTS COLIMN SLEEVE TO 3/I6 BASE RAIL 3/36 SDF'S RAFTER COLUMN/BASE RAIL ,CONNECTION DETAIL - SCALE, NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. BOX EAVE RAFTER COLUMN �\ CONNECTION DETAIL B L FOR HEIGHTS <_ 10'-0' SCALE: NTS 2 1/2' BRACE SECTION SCALE! NTS TUBULAR BUILDING SYSTEMS 30'-0"x2T-0" ENCLOSED BUILDING EXP. B 8B 4 BASE RAIL ANCHORAGE OPTIONS FOR LOW AND HIGH WIND SPEED F—WVF OR FIBERGLASS /�eu�Timv IiwoYm 3ege� )ePANSION 6• OF 4 / MINIMUM 3 1/4— - EMBEDMENT — TYPJ- __ MONOLITHIC CONCRETE ROOTING C3000PSI MIN) REINFORCED WITH j-j— VITH (2) 04's CONTINUOUS I CONCRETE MONOLITHIC SLAB / \BASE RAIL ANCHORAGE SCALES N7S (MINIMUM ANCHOR EDGE DISTANCE IS 4') COORDINATE WITH LOCAL CODES/ORD. GENERAL NOTES CONCRETE: CONCRETE SHALL HAVE A MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF 3,000 PSI AT 28 DAYS, COVER OVER REINFORCING STEEL: FOR FOUNDATIONS, MINIMUM CONCRETE COVER OVER REINFORCING BARS SHALL BE PER ACI-318: 3 INCHES IN FOUNDATIONS WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH THE EARTH DR EXPOSED TO THE EARTH OR WEATHER, AND 1/2 INCHES ELSEWHERE. _ REINFORCING STEEL) THE TURNDOWN REINFORCING STEEL SHALL BE ASTM A615 GRADE 60. THE SLAB REINFORCEMENT SHALL BE WELDED WIRE FABRIC MEETING ASTM A185 OR FIBERGLASS FIBER REINFORCEMENT. REINFORCEMENT MAY BE BENT IN THE SHOP OR THE FIELD PROVIDED) 1. REINFORCEMENT IS BENT COLD. 2. THE DIAMETER OF THE BEND, MEASURED ON THE INSIDE OF THE BAR, IS NOT LESS THAN SIX -BAR DIAMETERS. 3. REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT. HELIX ANCHOR NOTES) 1. FOR VERY DENSE AND/OR CEMENTED SANDS, COARSE GRAVEL AND COBBLES, CALICHE, PRELOADED SILTS AND CLAYS USE MINIMUM (2) 4' HELICES WITH MINIMUM 30 INCH EMBEDMENT. 2. FOR CORAL USE MINIMUM (2) 4' HELICES WITH MINIMUM 30 INCH EMBEDMENT. 3. FOR ME➢IUM DENSE COARSE SANDS, SANDY GRAVELS, VERY STIFF SILTS, AND CLAYS USE MINIMUM (2) 4' HELICES WITH MINIMUM 30 INCH EMBEDMENT. 4, FOR LOOSE TO MEDIUM DENSE SANDS, FIRM TO STIFF CLAYS AND SILTS ALLUVIAL FILL USE MINIMUM (2) 6' HELICES WITH MINIMUM 50 INCH EMBEDMENT. 5. FOR VERY LOSE TO MEDIUM DENSE SANDS, FIRM TO STIFFER CLAYS AND SILTS, ALLUVIAL FILL USE MINIMUM (2) 8' HELICES WITH MINIMUM 60 INCH EMBEDMENT. MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. 2' BOLT .._. _ .__ IS CONTIMOUs BASE RAIL HELIX EYE ANCHOR (SEE NOTES BELOW) J4 1GROUND BASE HELIX ANCHORAGE SCALES NTS (CAN BE USED FOR ASPHALT) TUBULAR BUILDING SYSTEMS 30'-0"x2W-O" ENCLOSED BUILDING EXP. B MY 9A OPTIONAL FOUNDATION ANCHORAGE FOR LOW & HIGH WIND SPEED RAIL WWF OR FIBERGLASS FIBERS Al 11 I__ GRADE - MINIMUM 6' - EMBEDMENT - ~C RVPA CONCRETE MONOLITHIC.SLAB / SASE RAIL ANCHORAGE SCALES NTS (MINIMUM ANCHOR EDGE DISTANCE IS 1 1/2') . COORDINATE WITH LOCAL CODES/ORD. GENERAL NOTES CONCRETE: CONCRETE SHALL HAVE A MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF 3,000 PSI AT 28 DAYS. COVER OVER REINFORCING STEEL: FOR FOUNDATIONS, MINIMUM CONCRETE COVER OVER REINFORCING BARS SHALL BE PER AC1-318� 3 INCHES IN FOUNDATIONS WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH THE EARTH OR EXPOSED TO THE EARTH OR WEATHER, AND 1 1/2 INCHES ELSEWHERE. REINFORCING STEEL) THE TURNDOWN REINFORCING STEEL SHALL BE ASTM A615 GRADE 60. THE SLAB REINFORCEMENT SHALL BE WELDED WIRE FABRIC MEETING ASTM A185 OR FIBERGLASS FIBER REINFORCEMENT. REINFORCEMENT MAY BE BENT IN THE SHOP OR THE FIELD PROVIDED: 1. REINFORCEMENT IS BENT COLD. 2. THE DIAMETER OF THE BEND, MEASURED ON THE INSIDE OF THE BAR, IS NOT LESS THAN SIX -BAR DIAMETERS. 3. REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT. :ETE ANCHOR ROD THROUGH BASE RAIL DETAIL 11' SCALE: NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. CONCRETE MONOLITHIC SLAB ( eta \ BASE RAIL ANCHORAGE u SCALE: NTS (MINIMUM ANCHOR EDGE DISTANCE IS 1 1/2'> x COORDINATE WITH LOCAL CODES/ORD. S. 57170 [ri 5 IE OF R1Q' TUBULAR BUILDING SYSTEMS 30'-0'k20W' ENCLOSED BUILDING EXP. B 9B IDWC, Mb SK-3 ]REV, 4 BOX EAVE RAFTER END WALL AND SIDE WALL OPENINGS TYPICAL BOX EAVE RAFTER END WALL FRAMING SECTION SCALE: NTS TYPICAL BOX EAVE RAFTER SIDE WALL OPENINGS FRAMING SECTION SCALE NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. SEE NOTES TYPICAL BOX EAVE RAFTER END WALL OPENINGS FRAMING SECTION INDON, NO ALSO END TUBULAR BUILDING SYSTEMS 30'-0" x20' 0" ENCLOSED BUILDING EXP. B ND SK-3 BOW RAFTER END WALL AND SIDE WALL OPENINGS TYPICAL BOX EAVE RAFTER END WALL FRAMING SECTION SCALE. NTS TYPICAL BOX EAVE RAFTER SIDE WALL OPENINGS FRAMING SECTION SCALE- NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. TYPICAL BOX EAVE RAFTER END WALL OPENINGS FRAMING SECTION SCALE, NTS VIND➢W AND (T su " END S. Nr 7170 152Wk: OF TUBULAR BUILDING SYSTEMS 30'4 x20' 0" ENCLOSED BUILDING E Q. B Km 1 BOW AND BOX EAVE RAFTER WALL OPENING DETAILS IS RAFTER IS COLUMN (CORNER) IS WLUMN MINIMUM 6- LONG, MINIMUM ON END COLUMN 15 GA., IS NIPPLE. SECURE 2'x2'x2' 16 GA ANGLE 'r WITH (4) B12-14x3/4' SDF'S CLIP SECURE TO COLUMN AND EITHER TOP OF 2'x2'x2' 16 GA, CLIP ANGLE HEA➢ER, OR BOTTOM OF 16 G14 ANGLE NPPLE Tp ]/16 SECURE TO RAFTER COLUMN WINDOW RAIL WITH CLIAND BASE RAIL ER C 8I2-14x]/4- SDF'S AND SECURE TO COLUMN BASE RAIL 3/16 AND RAFTER VITH 812-14x3/a' SDF'S 812-14x3/4' SDF'S 2 ON - TOP AND 2 ON SIDE e _ _ ___ _ _ IS END COLUMN - - ` — WI HEA➢ER OR '- '--_' _ - - "' WINDOW RAIL IS CONTINUOUS BASE RAIL HEADER OR WINDOW END COLUMN/RAFTER END COLUMN/BASE RAIL RAIL TO COLUMN 4 CONNECTION DETAIL CONNECTION DETAIL ( CONNECTION DETAIL SCALE. NTS 5 SCALES NTS 6 SCALE: NTS TS TRUSSED RAFTER CHORD, DR HEADER 3/16 NIPPLE TO - 39d 3/16 HEADER IS COLUMN NIPPLE TO 3/16 2'x2'x2. 16 CA. ANGLE HEADER •,T/16 _ MINIMUM 6' LONG, CLIP SECURE i0 COLUMN _ 1 _..__ __ _ MINIMUM IS SCk,ECURE TS TS END COLUMN (EACH SIDD> AND NIPPLE. SENRE OR DOOR WINDOW RAFTER CMpR➢/RAIL __ __ _ _ _ #WITH12- (4) FRAME POST 2 ON BOTTOM SDF'S p12-14a3/4• SDF'S 2 ON BOTTOM AND 2 ON 0 q SIDE MINIMUM 6• Gk.LDNO.I ---.� --�. NOTE: AT ROLL -UP DOOR NIPPLE.NIMUM E URE IS IS HEADER, BASE OPENINGS. POST SHOULp NIPPLE. SECURE EACH _ _._ RAIL, OR WIG, WITH f4) 812-14x3H• BE PLUSH WITH RAIL �'i- SDCS RAIL END. CLIP POST TO IS COLUMN 3-12 \-TIS DOUBLE HEADER RAIL ONLY ON SIDE 3_I2 ___. .. ... GPPESITE THE OPENING. COLUMN TO HEADER, COLUMN/DOUBLE HEADER BASE RAIL, OR DOUBLE HEADER/COLUMN 9 CONNECTION DETAIL WINDOW RAIL g CONNECTION DETAIL SCALE: NTS SCALE NTS 7 CONNECTION DETAIL SCALE: NTS S COLUMN MINIMUM 6' LONG, E TO 3/16 MINIMUM 15 G0.. IS RAIL 3A5 NIPPLE. SECURE EACH WITH co 412-14,3/4' SDF'S TS CONTINUOUS - - - -- BASE RAIL COLUMN/BASE RAIL 1 CONNECTION DETAIL 10 SCALE, NTS S. MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. 57170 i 1�1� rE OF . �4 P•?% TUBULAR BUILDING SYSTEMS 30'-0"x20W' ENCLOSED BUILDING EXP. B 12 .. N6 SK-3 8Ew 1 ROOF EXTENSION MAIN STRUCTURE STANDARD OPTION LEAN-TO OPTION 3 2 2 3 2 2 3 2 2 9 6 B 9 6 B 9 6 8 14� TYPICAL BOX EAVE RAFTER LEAN-TO OPTIONS FRAMING SECTION (BOTH OPTIONS SHOWN) SCALE. NTS MAXIMUM WIDTH OF SINGLE MEMBER RAFTER LEAN-TO IS 16'-0'. TS BOX EAVE RAFTER— NIPPLE TG " . / RAFTER 3/l6 I 12' LONG ISC 1E GA NIPPLE. SECURE SECURE WITH COLUMN TO NIPPLE (4) DI2-14x3H' SDF'S WITH [4) (EACH END) 912-14.3/4' SDF'S 6 e IB GA U-CHANNEL BRACE( MINIMUM 6' LONG,-/ MINIMUM Is GA. TS NPPLE. SECURE COLUMN TO NIPPLE WITH (4) 912-14x3/4' SDF'S IS COLUVNJ 14 SIDE EXTENSION RAFTER/COLUMN DETAIL SCALE: NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. 2'x2'x2. 16 GA. ANGLE CLIP SECURE TO COLUMN AND RAFTER WITH 012-14x3/4' S➢ 'S 2 ON TOP AND 2 ON BOTTOM TS RAFTER S CDWMN LEAN-TO RAFTER TO RAFTER 12 COLUMN CONNECTION DETAIL SCALE, NTS TUBULAR BUILDING SYSTEMS 30'-0"x2OW' ENCLOSED BUILDING EXP. B 13 OV4 N4 SK-3 BOW RAFTER LEAN-TO OPTIONS OF SINGLE MEMBER RAFTER LEAN-T❑ IS 16'-0'. 1SIDE EXTENSION RAFTER/COLUMN DETAIL SCALE: NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. TUBULAR BUILDING SYSTEMS 30'-O"x2O'-O" ENCLOSED BUILDING EXP. B ND SK-3 BOX EAVE RAFTER VERTICAL ROOF/SIDING OPTION TYPICAL END ELEVATION VERTICAL ROOF/SIDING OPTION SCALE: NTS i '�!+ t,II i G' � i�,3 1, f11jn;I I!' "' ' 'nr I 1 v u; 1 I� ti ,1„ ! i 1p �! , TYPICAL SIDE ELEVATION VERTICAL ROOF/SIDING OPTION SCALE. NTS NEL ROOF PANEL ATTACHMENT (ALTERNATE FOR VERTICAL ROOF PANELS) SCALE NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. TYPICAL SECTION VERTICAL RDOF/SIDING ❑PTION SCALE. NTS TYPICAL FRAMING SECTION VERTICAL ROOF/SIDING OPTION SCALE: NTS TUBULAR BUILDING SYSTEMS 30'-0"x2OW' ENCLOSED BUILDING EXP. B OPTIONAL DOOR HEADER 2 1/2x2 1/2-14 GA. (TYP.) 2 1/2x2 1/2-14 GA. 2 1/2x2 1/2-14 GA. (TYP.) i P-8' D.C. (TYP.) m N 3/16 - - 3/16 - TYP 3/16 TYP 3/16 HEADER 'DETAIL FOR DOOR OPENINGS 12'-0' < LENGTH < 15'-0' SCALE, NTS MOORS AND ASSOCIATES ENGINEERING AND CONSULTING, INC. HEADER DETAIL FOR DOOR ❑PENINGS LENGTH < 12'-0' SCALE: NTS TUBULAR BUILDING SYSTEMS 30'-0"x2O'-O" ENCLOSED BUILDING M. B JOB ND 12- B-17 SCALE- NTS 16022S/17300S 16 DVG NO SK-3 Eve 4