HomeMy WebLinkAboutENERGY CONSERVATION CODE CHECKLISTFORM R405-2017 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2017 Florida Building Code, Energy Conservation via the residential Simulated Performance method shall include: ❑ This Checklist 01 com ❑ A FORM 405 report that documents that the Proposed Design complies with Section R405.3 of the A31ida Energy Code. This form shall include a summary page indicating home address, a -ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worsticase orientation, name and version of the compliance software tool, name of individual completing the compliance report (one page). ❑ An input summary checklist that can be used for field verification (usually 4 pages/m ('ay be greater). ❑ Energy Performance Level (EPL) Display Card (one page) SCANNED St. Luce Counfv ❑ HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7 ❑ Mandatory Requirements (Five pages) Required prior to CO for the Performance method: ❑ Air Barrier and Insulation Inspection Component Criteria checklist (Table 402.4.1.1- one page) ❑ A completed Form 2017 Envelope Leakage Test Report (usually one page). Section R402.4 or R402.4.1.2 exceptions may apply. ❑ If FORM R405 duct leakage type indicates anything other than "default leakage" then a completed FORM R405 Duct Leakage Test Report (usually one page). wrightSO t" Right.SuiteO Universal 201919.0.09 RSU27054 Right-Energy®Florida 2017 section 405.4.1 Compliant Softwarre19 Jul-1610Page Page 1 wwYvf.e+.. m.�rfvs.n ...\Wnghtsofl HVAC1Kari Rohan Residence Groza.rup Cale =MJB Front Door faces: N FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Karl Rohan Builder Name: Groza Builders, Inc Street: 0 Shanas Trail Permit Office: City, State, Zip: Port St Lucie, FL 34952 Permit Number: Owner: Karl Rohan Jurisdiction: St Lucie Design Location: FL, St Lucie Co Intl - County: St Lucie (Florida Climate Zone 2) 1. New construction or existing New (From Plans) 9. Wall types (1753 ft') Insulation (R) Area (ft') 2. Single family or multiple family Single -Family a. Blk wall, stucco ext, r-9 ext bd 9.0 1402.00 b. Frn wall, 1/2" gyp.bd ext, r-11 11.0 350.75 3. Number of units, if multiple family 1 c. N/A 4. Number of bedrooms 4 d. N/A 10. Ceiling types (2015 ft') Insulation (R) Area (fN) 5. Is this a worst case? No a. Attic, asphalt shingles, r-30 ce 30.0 2015.25 6. Conditioned floor area above grade (ft') 2015.25 b. N/A Co ndilio ned floor area below grade ift') 0 c. N/A 7. Windows (153 fF) Description Area (ft') 11. Ducts R Area (ft') aia`P: coca 6euse M. aeccPee HnmeNti, n6: runcPoa�nPPcalareP 6.0 0.00 a. U-Factor: Dbl Impact, 0.300 100.73 b. SHGC: 0.20 It. 1-1-Factor. Dbl, 0.300 52.00 12. Cooling systems kBtu/hr Efficiency SHGC: 0.20 a.Split air conditioner 34.6 SEER: 16.0 c. U-Factor: b. SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: a.Electdc strip 22.5 AFUE: 100.0 SHGC: b. Area Weighted Average Overhang Depth: 1.600 ft 14. Hot water systems Area Weighted Average SHGC: 0.200 a.Electric conventional (40 gal) Cap: 40 gal EF: 0.95 8. Floor types (2015.25 fN) Insulation (R) Area (ft') b.Conservation features a. On grade depth, Tile fir Irish 0.0 2015.25 (None) b. N/A c. N/A 15. Credits None Glass/Floor area: 0.076 Total Proposed Modified Loads: 52.23 PASS Total Baseline Loads: 57.68 I hereby certify that the plans and specifications covered by Review of the plans and specifications Y�gES7- this calculation are in compliance with the Florida Energy covered by this calculation indicates compliance with the Florida Energy VO &'p Code. r / • / • // _ - ! PREPARED BY: / �/1LYGrZ Gn eIZl7PiL� Code. Before construction is completed, this building will be inspected for y w1y, sn f" "���r w _ compliance with Section 553.908 -',� -+ 70 - DATE: 07/16/2019 Florida Statutes. I, •��•��� e COA I hereby certify that this building, as designed, is in compliance with the Florid E rg WE,�� OWNER/AGENT: BUILDING OFFICIAL: DATE: -I ' DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50 (R402.4.1.2). 2019-Jul-1610:06:27 wrightsoft° Right -Suite® Universal 201919.0.09 RSU27054 Right-Energy®Florida 2017 Section 405A.1 Compliant Software Page evx:asmr.. w.gr�wa ...\bVfighlsom HVACWad Rohan Residence Groza.rup Calc=MJ8 Front Doorfaces: N FORM R405-2017 Building Input Summary Report PROJECT Title: Karl Rohan Bedrooms: 4 Address type: Street address Building Type: FLAsBuilt Bathrooms: 3 Lot#: Owner: Karl Rohan Conditioned Area: 2015 Block/Subdivision: # of Units: 1 Total Stories: 1 Platbook: Builder Name: Groza Builders, Inc Worst Case: No Street: 0 Shanas Trail Permit Office: Rotate Angle: 0 County: St Lucie Port St Lucie, FL 34952 Jurisdiction: St Lucie Cross Ventilation: No City, State, Zip: Family Type: Single -Family Whole House Fan: No Ocean/Lake New/ New (From Plans) Terrain: Year Construct: Shielding: Suburban Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp ✓ Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, St Lucie Cc Intl FL Fcrt_Pierce 2 41 90 70 75 486 57 Low BLOCKS # Name Area Volume 1 Cond House 2015.25 fP 17602.30 ft' SPACES # Area Volume Kitchen Occupants Bedrooms Infl ID Finished Cooled Heated 1 Bath 3 74.75 ft2 598.00 fP No 0 0 1 Yes Yes Yes 2 Bed 4 198.25 ft2 1586.00 ft' No 0 1 1 Yes Yes Yes 3 Wtr Clst 26.00 ft2 208.00 ft3 No 0 0 1 Yes Yes Yes 4 Master Bath 101.88 ft2 815.00 ft3 No 0 _ 0 1 Yes Yes Yes Yes Yes Yes 5 WIC 58.88 W 471.00 ft' No 0 0 1 6 Master Suite 261.00 ft2 2296.80 ft' No 0 1 1 0 1 Yes Yes Yes Yes Yes Yes 7 8 Dining Room 204.00 fP Pantry 16.00 ft' 1938.00 ft3 No 0 152.00 ft' No 0 0 1 Yes Yes Yes 9 Kitchen 239.00 ft' 2270.60 fP Yes 2 0 1 Yes Yes Yes Yes 10 Living Room 322.00 ft2 3059.00 fP No 3 0 1 1 Yes Yes Yes Yes Yes 11 12 Laundry 64.75 ft2 Bed 3 150.75 ft2 518.00 ft3 No 0 1206.00 fP No 0 0 1 1 Yes Yes Yes 13 Bed 2 175.00 ft2 1400.00 ft' No 0 1 1 Yes Yes Yes 14 Bath 2 68.75 ft' 550.00 ft' No 0 0 1 0 1 Yes Yes Yes Yes Yes Yes 15 16 Hall 38.00 ft2 Clst 16.25 ft2 304.00 fP No 0 130.00 W No 0 0 1 Yes Yes Yes FLOORS (Total Exposed Area = 2015 sq.ft.) # Floor Tye Space Perimeter R-Value Area U-Factor Tile Wood Carpet 1 On grade depth, Tile flr fnsh Bath 3 24 ft 0 74.75 ft2 0.989 1.0 0 0 2 On grade depth, Tile flr fnsh Bed 4 19 ft 0 198.25 ft' 0.989 1.0 0 0 0 3 On grade depth, Tile flr fnsh Wtr Clst 0 ft 0 26.00 ft2 0.989 1.0 0 4 On gratle depth, Tile flr fnsh Master Bath 8 ft 0 101.88 ft2 0.989 1.0 0 0 5 On grade depth, Tile flr fnsh WIC 0 ft 0 58.88 ft' 0.989 1.0 0 0 0 6 On grade depth, Tile flr fnsh Master Suite 33 ft 0 261.00 ft2 0.989 1.0 0 0 7 On grade depth, Tile flr fnsh Dining Room 17 ft 0 204.00 ft2 0.989 1.0 0 0 8 On grade depth, Tile flr fnsh Pantry 0 ft 0 16.00 ft2 0.989 1.0 0 9 On grade depth, Tile flr fnsh Kitchen 0 ft 0 239.00 ft2 0.989 1.0 0 0 10 On grade depth, Tile flr fnsh Living Room 15 ft 0 322.00 ft2 0.989 1.0 0 0 0 11 On grade depth, Tile flr fnsh Laundry 0 ft 0 64.75 ft2 0.989 1.0 0 0 12 On grade depth, Tile flr fnsh Bed 3 13 ft 0 150.75 ft2 0.989 1.0 0 13 On grade depth, Tile flr fnsh Bed 2 27 ft 0 175.00 ft2 0.989 1.0 0 0 14 On grade depth. Tile flr fnsh Bath 2 6 ft 0 68.75 ft 0.989 1.0 0 0 16 On grade depth, T le flr fnsh Hall 7 ft 0 16.25 ft' 0.989 1.0 0 0 ROOF Roof Gable Roof Solar SA Emitt Emitl Deck Pitch f # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 2 Hip RoofAsph 2183 ft2 Hip RoofAsph 474 W Medium 0.75 No Medium 0.75 No 0.90 0.90 No No 0 23 0 23 2019-Jul-1610:06:27 wrightsoft" Right -Suite® Universal 201919.0.09 RSU27054 Right-Energys, Flodda 2017 Seclion 405.4.1 Compliant Software Page _.\Wrighlsoft HVACtKad Rohan Residence Grozasup Cale = MJ8 Front Door faces: N G(1RN7 RAnS-,)r117 ATTIC ✓ # Type Ventilation Vent Ratio 1 in Area FIBS IRCC 1 Full attic Vented 150 2015.25ft2 N N 2 Full attic Vented 150 437.75 ft' N N CEILING (Total Exposed Area = 2015 sq.ft.) # Ceilinci Type Space R-Value I. -Factor Area Framincl Fraction Truss Type 1 Attic, asphalt shingles, r-30 cell i Bath 3 30 0.034 74.75 ft2 0.10 Wood 2 Attic, asphalt shingles, r-30 cell t Bed 4 30 0.034 198.25 ft' 0.10 Wood 3 Attic, asphalt shingles, r-30 ceil i Wtr Clst 30 0.034 26.00 ft2 0.10 Wood 4 Attic, asphalt shingles, r-30 ceil 1 Master Bath 30 0.034 101.88 ft2 0.10 Wood 5 Attic, asphalt shingles, r-30 ceil i WIC 30 0.034 58.88 ft2 0.10 Wood 6 Attic, asphalt shingles, r-30 ceifi Master Suite 30 0.034 261.00 ft- 0.10 Wood. 7 Attic, asphalt shingles, r-30 ceil i Dining Room 30 0.034 204.00 ft' 0.10 Wood 8 Attic, asphalt shingles, r-30 cell i Pantry 30. 0.034 16.00 ft2 0.10 Wood 9 Attic, asphalt shingles, r-30 ceil i Kitchen 30 0.034 239.00 ft2 0.10 Wood 10 Attic, asphalt shingles, r-30 ceil i Living Room 30 0.034 322.00 ft2 0.10 Wood 11 Attic, asphalt shingles, r-30 cell i Laundry 30 0.034 64.75 ft- 0.10 Wood 12 Attic, asphalt shingles, r-30 cell 1 Bed 3 30 0.034 150.75 ft 0.10 Wood 13 Attic, asphalt shingles, r-30 ceil i Bed 2 30 0.034 175.00 ft2 0.10 Wood 14 Attic, asphalt shingles, r-30 ceil i Bath 2 30 0.034 68.75 W 0.10 Wood 15 Attic, asphalt shingles, r-30 ceil i Hall 30 0.034 38.00 ft2 0.10 Wood 16 Attic, asphalt shingles, r-30 cell 1 Clst 30 0.034 16.25 ft' 0.10 Wood WALLS (Total Exposed Area = 1753 sq.ft.) Adjacent Cavity Width Height Sheathing U- Fnn. Solar Below # Omt To Wall Type Space R-Value Ft In Ft In Area R-Value Factor Frac. Absor. Grade% 1 NE Exterior Blk wall, stucco Bath 3 0 11 6 8 0 92.0 ft' 9 0.095 0.22 0.75 0 2 SE Exterior Blk wall, stucco Bath 3 0 6 0 8 0 48.0 ft2 9 0.095 0.22 0.75 0 , 3 NW Exterior Blk wall, stucco Bath 3 0 6 0 8 0 48.0 W 9 0.095 0.22 0.76 0 4 NE Exterior Blk wall, stucco Bed 4 0 5 0 8 0 40.0 ft2 9 0.095 0.22 0.75 0 5 NW Exterior Blk wall, stucco Bed 4 0 14 0 8 0 112.0 ft2 9 0.095 0.22 0.75 0 6 NW Exterior Blk wall, stucco Master Bath 0 7 6 8 0 60.0 W 9 0.095 0.22 0.75 0 7 SW Exterior Blk wall, stucco Master Suite 0 14 6 810 127.6 ft' 9 0.095 0.22 0.75 0 8 NW Exterior Blk wall, stucco Master Suite 0 18 0 8 10 158.4 ft' 9 0.095 0.22 0.75 0 9 SW Exterior Blk wall stucco Dining Room 0 17 0 9 6 161.5 fl' 9 0.095 0.22 0.75 0 10 - Partition Fnn wall, 1/2" gy Dining Room 11 12 0 9 6 114.0 ft2 0 0.097 0.25 0.75 0 11 - Partition Fnn wall, 1/2" gy Pantry 11 4 0 9 6 38.0 ft2 0 0.097 0.25 0.75 0 12 - Partition Firm wall, 1/2" gy Kitchen 11 4 6 9 6 42.8 ft' 0 0.097 0.25 0.75 0 13 NE Exterior Blk wall, stucco Living Room 0 15 0 9 6 142.5 f? 9 0.095 0.22 0.75 0 14 Partition Frm wall, 112" gy Laundry 11 9 0 8 0 72.0 ft2 0 0.097 0.25 0.75 0 15 BE Exterior Blk wall, stucco Bed 3 0 13 0 8 0 104.0 ft2 9 0.095 0.22 0.75 0 16 - Partition Firm wall, 1/2" gy Bed 3 11 10 6 8 0 84.0 fl2 0 0.097 0.25 0.75 0 17 NE Exterior Blk wall, stucco Bed 2 0 14 0 8 0 112.0 ft' 9 0.095 0.22 0.75 0 18 BE Exterior Blk wall, stucco Bed 2 0 12 6 8 0 100.0 ft' 9 0.095 0.22 0.75 0 19 NE Exterior Blk wall, stucco Bath 2 0 5 6 8 0 44.0 ft' 9 0.095 0.22 0.75 0 20 NW Exterior Blk wall, stucco Gist 0 6 6 8 0 52.0 ft2 9 0.095 0.22 0.75 0 DOORS (Total Exposed Area = 21 sq.ft.) Width Height # Ornt Door Type Space Storms U-Value Ft In Ft In Area 1 SW Door, mtl fbrgl type Dining Room None 0.127 3 0 7 0 21.0 ft' WINDOWS (Total Exposed Area =153 sq.ft.) Wall Overhang Interior # Omt ID Frame Panes NFRC U-Factor SHGC Impact Area Depth Separation Shade Screening 1 NE 1 Vinyl Double Mnted) Yes 0.300 0.20 Yes 4.Oft2 1 ft 7 in 1 ft 0 in Blinds 45' outdoor 2 NW 5 Vinyl Low- E Double Yes 0.300 0.20 Yes 15.6ft2 1 ft 7 in 1 ft 0 in Blinds 45" outdoor 3 NW 6 Vinyl Double (Tinted) Yes 0.300 0.20 Yes 4.0ft2 1 ft 7 in 1 It 0 in Blinds 45" outdoor 4 SW 7 Vinyl Low-E Double Yes 0.300 0.20 Yes 23.0ft2 1 ft 7 in 1 ft 0 in Blinds 45' outdoor 5 SW 9 Vinyl Low-E Double Yes 0.300 0.20 Yes 23.Oft' 1 It 7 in 1 ft 0 in Blinds 45° outdoor 6 NE 13 In Low-E Double Yes 0.300 0.20 No 52.Oft2 1 ft 7 in 1 ft 0 in Blinds 45' outdoor 7 SE 15 Vinyl Low-E Double Yes 0.300 0.20 Yes 15.6ft2 1 ft 7 in 1 ft 0 in Blinds 45' outdoor GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 0 INFILTRATION # Scope Method SLA CFM 50 ELA E LA ACH ACH 50 1 Wholehouse Simplified 0.000387 2042 112.3 210.9 0.53 7.00 F{rl wrightSoft" Right -Suite® Universal 201919.0.09 RSU27054 Right -Energy® Florida 2017 Section405.4.1 Compliant Sof waml9 Jul-1610:06:27 ,vw•is, .,,,r,.,,e�,r.,,, .-Minghlsoft HVACUCad Rohan Residence Groza.mp Calc=MJ8 Front Door faces: N Page rn101!4 oenr nA47 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts - I Electric strip AFUE: 100.0 22.5 kBtu/hr 1 s s#1 COOLING SYSTEM { # System Type Subtype Efficiency CapacityCapaclity Air Flow SHR Block Ducts - 1 Split air conditioner SEER: 16.0 34.6 kBtu/hr 1153 cfm 0.70 1 s s#1 HOT WATER SYSTEM f # System Type Subtype Location EF Cap Use SetPnt Conservation 1 Electric conventional 0.95 40 gal 70 gal 120T None DUCTS — Supply Return -- Air CFM 25 Percent HVAC ## Location R-Value Area Location Area Leakage Type Handler Out Leakage QN RLF Heat Cool 1 Cond House Atti 6.0 Oft' Cond House Atti Oft' oefault Leakage (uncondlaoned)Attie (Default) 6.00 1 1 TEMPERATURES Programmable Thermostat: N Ceiling Fans: Cooling [ X ]Jan [ X] Feb [XI Mar [ X] Apr [ X] May [[ X] Jun [ X] Jul [ X] Aug [ X] Sep [ X] Oct [ X] Nov [ X] Dec Heating [ X ]Jan [ X] Feb [ X] Mar [ X] Apr [ X] May [ X] Jun [ X] Jul [ X] Aug [ X] Sep [ X] Oct [ X] Nov [ X] Dec Venting X Jan X Feb X Mar X1 Apr X I May X Jun [ X Jul X1 Aug j X] Se X I Oct X1 Nov j Xj Dec Thermostat Schedule: Florida Building Code, 6th Edition Hours Scheduler a 2017 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Cooling (WEH) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Heating (WD) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 Heating (WEH) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 2019-Jul-1610:06:27 #wrightSofte RightSuite® Universal 201919.0.09 RSU27054 Right-EnergyO Florida 2017 Section 405.4.1 Compliant Software Page ._Wightsoft HVACIKad Rohan Residence Groza.rup Colo =MJ8 Front Door faces: N FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX = 91 The lower the EnergyPerformance Index, the more efficient the home. 1. New home or addition 1. New (From Plans) 12. Ducts, location & insulation level a. Supply ducts: R 2. Single-family or multiple -family 2. Single -Family b. Return ducts: R c. AHU location: (Unconditioned) Attic 3. Number of units, if.multiple-family 3. 1 4. Number of bedrooms 4. 4 5. Is this a worst case? (yes/no) 5. No 6. Conditioned floor area (ft2) 6. 2015.25 7. Windows, type and area* a. U-Factor: 7aDbl Impact. 0.300 b. Solar Heat Gain Coefficient (SHGC): 7b. 0.20 c. Area (ft� 7c. 100.73 8. Skylights a. U-Factor: b. Solar Heat Gain Coefficient (SHGC): 9. Floor type, insulation level a. Slab -on -grade (R-value): b. Wood, raised (R-value): c. Concrete, raised (R-value) 10 Wall type and insulation: a. Exterior: 1. Wood frame (Insulation R-value): 2. Masonry (Insulation R-value): b. Adjacent: 1. Wood frame (Insulation R-value): 2. Masonry (Insulation R-value): 11. Ceiling type and insulation level a. Under attic (R-value): b. Single assembly (R-value): c. Knee walls/skylight walls (R-value) d. Radiant barrier installed 8a. 8b. 13. Cooling systems Capacity 34.6 a. Split system: SEER 16.00 b. Single package: SEER c. Ground/water source: SEER/COP d. Room unit/PTAC: EER e. Other: 14. Heating systems Capacity 22.5 a. Split system heat pump: HSPF b. Single package heat pump: HSPF c. Electric resistance: COP 100.00 d. Gas furnace, natural gas: AFUE e. Gas furnace, LPG: AFUE f. Other. 15. Water heating systems a. Electric resistance: EF 0.950 9a. 0.0 b. Gas Fred, natrual gas: EF 9b. c. Gas fired, LPG: EF 9c. d. Solar system with tank: EF e. Dedicated heat pump with tank: EF f. Heat recovery unit: HeatRec% g. Other: 10a1. 10a2. 9 16. HVAC credits claimed (Performance Method) a. Ceiling fans: 10b1. 11 b. Cross ventilation: 10b2. c. Whole house fan: d. Multizone cooling credit: e. Multizone heating credit: 11a. 30.0 f. Programmable thermostat: 11b. 11C. 11d. *Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: A!-! C?q6 Address of New Home: 0 Shanas Trail Date: 1-Zy - I I City/FL Zip: Port St Lucie, FL 34952 2019-Jul-1610:06:27 # wright Soft" Right -Suit O Universal 201919.0.09 RSU27054 Right -Energy® Florida 2017 Section 405A.1 Compliant Software Page .vm•rs".r..ue...ra. ...%Wrightsoft HVACV(ari Rohan Residence Groza.rup Calc= MJ8 Front Door faces: N FORM R405-2017 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: 0 Shanas Trail PERMIT #: Port St Lucie. FL 34952 MANDATORY REQUIREMENTS - See individual code sections for full details. SECTION R401 GENERAL It/ R401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before finalapprovalof the building for occupancy. Florida law (Section 553.9085, Florida Statues) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. completed and signed by the builder The building official shall verify that the EPL display card accurately reflects the plans and specifications submitted to demonstrate compliance for the building. A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. ll R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance w ith the manufacturer's instructions and the criteria fisted in Table 402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(0(g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Healing and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. R402.4.2 Fireplaces. New wood -burning fireplaces shall have light -fitting flue dampers or doors, and outdoor combustion air. Where using tight -fitting doors on factory -built fireplaces listed and labeledin accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight-figging doors on masonry freplaces,the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air leakage. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or AAMANJDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. Right -Suite® Universa1201919.0.09 RSU27054 Ri ht-Ever ® Flodda 2017 Section 405.4.1 Com Ilan Soawarel&Jul-1610:06:27 w-j g-I oft' 9 9Y P Page7 avuris �.. n.:..,,m.o,1 ...\Wrighlsoft HVACUCari Rahan Residence Groza.rup Cale =MJ6 Front Door faces: N FORM R405-2017 MANDATORY REQUIREMENTS -(Continued) R402.4.4 Rooms containing fuel -burning appliances In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gaskeled and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent apliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. El R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than 2.0 cim (0.944 Us) when tested in accordance with ASTM E283 at a 1.57-psf (75Pa) pressure. differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interiorwall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the healing load. R403.3.2 Sealing (Mandatory). All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNETACC 380 by either individuals as defined in Section 553.993(5) or (7). Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i), Florida Statutes, to be "substantially leak free" in accordance with Section R403.3.3. R403.3.2.1 Sealed air handier. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design air flow rate when tested in accordance with ASHRAE 193. ❑ R403.3.3 Duct testing. Ducts shall be pressure tested to determine air leakage by one of the following methods: 1. Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. Post construction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. All registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. ❑ R403.3.5 Building Cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F(4 VC) or below 55°F (13°C) shall be insulated to a rani um of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance, and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace termperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall be dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for how water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. ❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 516.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. Right -Suite® Universal 201919.0.09 RSU27054 Ri ht-Energy® Florida 2017 Section 405.4.1 Compliant Softwar0e 3Ju1-1610Page wright5 oft' 9 Page 8 ...\wrightsoO FiVACVCari Rohan Residence Grozamp Colo =MJa Front Door faces: N FORM R405-2017 MANDATORY REQUIREMENTS -(Continued) R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. Extemal heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies (Mandatory). R403.5.6.1 Storage water heater temperature controls. R403.5.6.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100°F to 140°F (38°C to 60°C). R403.5.6.1.2 shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems tobe turned off..A separate valve shall be provided to permit the energy supplied to the main burners) of combustion types of service water heating systems to be turned off. 0 R403.5.6.2 Water heating equipment Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water healers shall met the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water heating system. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1. Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water -heating systems should meet the 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. El R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation, including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. El R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure of for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed spaces(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or R-19, space permitting, or R-10 otherwise. ❑ R403.7 Heating and cooling equipment (Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved methodologies, heating and cooling calculation based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement healing and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM CFM MINIMUM EFFICACY (a) CFMANATT AIRFLOW RATE MAXIMUM CFM Range hoods Any 2.8 cfm/watt Any In -line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cfm/watt < 90 Bathroom, utility room 90 2.8 cfm/watt Any For SI: 1 cfm - 28.3 L/min. (a) When tested in accordance HVI Standard 916 4F wrightSoft' Right-SuileO Universal 201919.0.09 RSU27054 Right -Energy® Florida 2017 Section 405A.1 Compliant softwarel�Jul-7610Page ...wvrightsofi HVAC%Kad Rohan Residence Groza.rup Calc=MJ8 Front Door faces: N Page9 ' MANDATORY REQUIREMENTS -(Continued) El R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AFRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded performance data, the design value or entering wet -bulb temperature and the design value for entering dry-bulb temperature Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains If the return duct(s) is installed in an unconditioned space. Exceptions: 1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling rapacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. R403.7.1.2.1 Heat pumps Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times grealerthan the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1 R403.7.1.2.3 Fossil fuel heating equipment The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. ❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment rapacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or healing within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or healing to the major entertainment areas. 2. A variable capacity system sized for optimumperformance during base load periods is utilized. R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. El R403.9 Snow melt and ice system controls (Mandatory). Snow- and ice -melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the systemw hen the pavement temperature is above 50°F (1 VC), and no precipitation is falling and an automatic or manual control that w ill allow s hutoff w hen the outdoor temperature is above 40"F (4.8°C). rl R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. El R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an integral partof the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots. ❑ R403.10.2 Time switches. Time switches or other control methods that can automatically turnoff and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operations. 2. Pumps that operate solar- and waste -heat -recovery pool healing systems. 3. Where pumps are powered exclusively from on -site renewable generation. R403.10.3 Covers. Outdoor healed swimming pools and outdoor permanent spas shall be equipped with a vapor- retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required. ❑ R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for healers manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 2019-Jul-16 10:06:27 " WrightSOft" Right-Suite(D Universal 201919.0.09 RSU27054 Right -Energy® Florida 2017 Section 405.4.1 Compliant Software Page 10 m r.,•rm,u.,iu..+ra,o,y ...\wdghtsoft HVAC\Kari Rohan Residence Groza.mp Calc=We Front Door faces: N MANDATORY REQUIREMENTS - (Continued) Ej R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heal pumps are not required to meet this standard. R403.11 Portable spas (Mandatory). The energy consumption of electric -powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps inpermanentlyinstalled lighting fixtures shall be. high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps. Exception: Low -voltage lighting. ❑ R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. I 2019-Jul-1610.06.27 #wrightsofto RightSuite® Universal 201919.0.09 RSU27054 Right-Energy(g) Florida 2017 Section 405.4.1 Compliant Software page ll rwava.er..v...�wo-o- ...Wighlsofl HVACW(an Ronan Residence Groza.rup Calc=MJ8 Front Door faces: N FORM R405-2017 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Karl Rohan Builder Name Groza Builders, Inc Street: 0 Shanas Trail Permit Office: City State, Zip: Port St Lucie, FL 34952 Permit Number. Owner: Kari Rohan Jurisdiction: St Lucie Design Location: FL, St Lucie Co In0 COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA V General A continuous air barrier shall be installed in the requirements q building envelope. The exterior thermal envelope Air-permeable eapermreat lean insulation shall not be used as a ❑ contains a continuous barrier. Breaks orjoints in the 9 air barrier shall be sealed. Ceilinglattic The air barrier in any dropped ceiling/soffit Theinsulationin any droppedceiling/soffit. shall be aligned with the insulation and any shall be aligned with the air barrier. gaps In the air barrier shall be sealed. ❑ Access openings, drop down stairs or knee wall doors to unconditioned attics paces shall be sealed. Walls The junction of the foundation and sill plate Cavities with corners and headers of frame walls shall be sealed.The junction of the top plate shall be insulated by completely filling the cavity and the top of exterior walls shall be sealed. with a material having a thermal resistance of R-3 ❑ Knee walls shall be sealed. per inch minimum. Exterior thermal envelope Insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier Windows, skylights doors The space between windowldoorjambs and framing, framing be ❑ and and skylights and shall sealed. Rimjoists are insulated and include an air Rimjoists shall be insulated. ❑ Rim joists barrier. Floors (including The air barrier shall be installed at any exposed Floor framing cavity Insulation shall be installed above -garage and edge of insulation. to maintain permanent contact with the underside cantilevered floors) of subfloor decking, or floor framing cavity insulation shall be permitted to be in contact El the top sideof sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space Exposed earth in unvented crawl spaces shall be Where provided in lieu of floor insulation, walls covered with a Class I vapor retarder with insulation shall be permanently attached ❑ overlapping joints taped. to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall ❑ be sealed. Narrow cavities Batts in narrow cavities shall be out to fit, or narrow cavities shall be filled by insulation that ❑ on installation readily conforms to the available cavity spaces. Garage Air sealing shall be provided between the garage ❑ separation and conditioned spaces. Recessed Recessed light fixtures installed in the building Recessed light fixtures installed in the lighting thermal envelope shall be sealed to the drywall. building thermal envelope shall be airtight ❑ and IC rated. ' Plumbing and Batt insulation shall be cut neatly to fitaround wiring wiring and plumbing in exterior walls, or insulation that on installation readily conforms ❑ to available space shall extend behind piping and wiring. Showeritub on The air barriershall be installed behind Exteriorwalls adjacentto showers and tubs exterior wall electrical or communication boxes or air -sealed shall be insulated. ❑ boxes shall be installed. Electricallphone The air barrier shall be installed behind box on exterior electrical or communication boxes or air -sealed ❑ walls boxes shall be installed. HVAC register HVAC register boots that penetrate building boots thermal envelope shall be sealed to the subfloor ❑ or drywall. Concealed When required to be sealed, concealed fire sprinklers sprinklers shall only be sealed in a manner that is recommended by the manufacturer. ❑ Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of [CC-400. - wrightsofto Right-Suitem Universal 201919.0.09 RSU27054 Rig ht-Energy®Florida 2017 section 405.4.1 Compliant 5oftwarel9Ju1161 age 12 marrs.n., a-.wcs.,r ...Wrihlsoft HVACVCan Rohan Residence Groza.rup Calc=MJ8 Front Door faces: N FORM R405-2017 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, Sth Edition Jurisdiction: St Lucie Permit Number. Job Information Builder: Groza Builders, Inc Community: Lot: Address: 0 Shanas Trail Unit: City: Port St Lucie State: FL Zip: 34952 Air LeakageTest,Results Passing results must meet either the Performance, Prescriptive, or ERI Method. ❑ PRESCRIPTIVE METHOD The building or dwelling unit shall be tested and'verified as having an air leakage rate of not exceeding 7 airchanges per hour at a pressure of 0.2 inch w.g. (50 pascals) in Climate Zones 1 and 2: ❑The building or dwelling unit shall be tested and verified as having an air leakage rate of .not PERFORMANCE or ERI METHOD' exceeding the selected ACH(50) value, as shown on FORM R405-2017 (Performance) or R406-2017 (ERI), section labeled as Infiltration, sub -section ACH50. ACH(50) specified on Form R405-2017-Energy Calc (Performance) or R406-2017 (ERI): 7.000 x60 _ 17502 - Method for calculating building volume: TM(50) Building Volume ACH(50) ❑ Retrieved from architectural plans ❑ PASS ❑,r Code software calculated ❑ When ACH(50) is less than 3, Mechanical Ventilation installation ❑ Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues, or individuals licensed as set forth in Section 489.105(3)(0, (g), or (i) or and approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the lest, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: wrightsoft" Right-SuiteUniversal 2019 RSU27054 Rig ht-EneraY®Florid a 2017 Sec ion 405.4.1 Compliant Sof war2013Ju1A61006.27 e page l3 rvr3af�u.. �nevvmwn ...\Wrighlsoft HVACUCari Rohan Residence Groza.rup CaIc=MJa Front Door faces: N FORM R405-2017 Duct Leakage Test Report Residential Peescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: St Lucie Permit Number. Job.information Builder: Groza Builders, Inc Community: Lot: Address: 0 Shanas Trail Unit: City: Port St Lucie State: FL Zip, 34952 Duct Leakage Test Results System 1 cfm25 System 2 cfm25 System 3 cfm25 Sum of any additional systems cfm25 sysfenl5all cfm25 _ 2015 Total of all Total Conditioned systems Square Footage ❑ PASS 0 ❑ FAIL ❑ Prescriptive Method drn25'(rotal) To qualify as "Suhstantially.leak free" Qn Total must be less than'or equal to 0.04 if air handler.unit is installed. If air handler unit.is not installed, an Total must be less than or equal to 0.03. This testing method meets the requirements. in accordance with Section'R403.3.3. Is the air handier Unit installed YES (<=o.o4on) during testing? NO (<=o.oQn) ❑ Performance / ERI'Method cfm25 (Out or Total) , To qualify,using this method, Qn must be.not greater than the proposed ductleakage Qn specified on Form R405-2017 or R406-2017. Leakage Type selected on Form Qn specified on Form R405-2017 R405-2017 (Energy Calc) or R406-2017 (Energy Qalc) or R4b6-2017 Default Leakage Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(0, (g) or (i), Florida Statues. I Testing Company Company Name: Phone: I hereby verify that the above duct leakage test results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Printed Name of Tester: License/Certification #: Date of Test: Issuing Authority: FIl wrightsoft° Right -Suite® Universal 201919.0.09 RSU27054 Right -Energy® Flodda2017 Section 405.4.1 Compliant Saf.R019Jul-1610:06.27 -r avr..af..w,un..,m.em ...\Wrighlsofl HVAC\Kad Rohan Residence Groza.rup Calc=MJS Front Door faces: N Page 14 Reference Home Characteristics Kari Rohan 0 Shanas Trail Port St Lucie, FL 34952 Above -grade Walls (Uo) Above -grade Wall Solar Absorptance Above -grade Wall lnfared Emittance Basement Walls (Uo) Above -grade Floors (Uo) Slab Insulation R-Value Ceilings (Uo) Roof Solar Absorptance Roof lnfared Emittance Attic VentArea (ft� Crawlspace Vent Area (ft� Exposed MasonryFloorArea (ft2) Carpet & Pad R-Value Door Area (ft� Door U-Factor North Window Area (8� South Window Area (ft� East Window Area (M West Window Area (ft� Window U-Factor Window SHGC (Heating) Window SHGC (Cooling) ACH50 Internal Gains' (Btu/day) Water heater gallons per day Water Heater set point temperature Water heater efficiency rating Labeled Heating System Rating and Efficiency Labeled Cooling System Rating and Efficiency Air Distribution System Efficiency Thermostat Type Heating Thermostat Settings Title: Karl Rohan Residence Groza FLBase2017 0.084 0.75 0.90 n/a n/a 0.0 0.030 0.75 0.90 6.72 n/a 490.60 2.0 40.00 0.400 38.18 38.18 38.18 38.18 0.400 0.2169 0.2169 7.00 82279 70.00 120.00 0.95 HSPF = 8.2 SEER = 14.0 0.88 Manual 72.0 (All hours) TMY City: FL —Fort —Pierce Air Calcs, LLC Load Short Form Cond House Air Calcs, LLC Job: 598 Date: JuI 16, 2019 By. Vicki Lynne Barenberg 7550"ddenHan ckLRVeroBeach FL32966Phore:772.800.8413 Emai1:NddVre@airca1=.mm File COPY For. Karl Rohan, Groza Builders, Inc 0 Shanas Trail, Port St Lucie, FL 34952 BY Sf. dude Coanty Design Information Htg CIg Infiltration Outside db (OF) 41 90 Method Simplified Inside db (°F) 70 75 Construction quality Average Design TO(°F) 29 15 Fireplaces 0 Daily range - L Inside humidity (%) 30 50 Moisture difference (gr4b) 2 57 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Lennox Trade Trade LENNOX Model Cond 14ACXS036-23W* AHRI ref Coil CBA27UHE-036-230'++TDR AHRI ref 10259480 Efficiency 100 EFF Efficiency 13.0 EER,16 SEER Heatinginput 6.6 kW Sensible cooling 24220 Btuh Heating output 22457 Btuh Latentcooling 10380 Btuh Temperature rise 18 OF Total cooling 34600 Btuh Actual airflow 1153 cfin Actualairflow 1153 cfin Airflowfactor 0.053 dm/Btuh Air flow factor 0.052 cfmBtuh Static pressure 0.60 in H2O Static pressure 0.60 in H2O Space thermostat Load sensible heat ratio 0.76 ROOM NAME Area (fit) Htg load (Btuh) Clg load (Btuh) HtgAVF (cim) CIgAVF (cfm) Bath 3 75 2387 874 126 45 Bed 198 2226 1756 117 91 WtrClst 26 36 67 2 3 Master Bath 102 1398 768 74 40 WIC 59 82 151 4 8 Master Suite 261 3987 2545 210 132 Dining Room 204 2762 2097 145 109 Pantry 15 172 125 9 6 IGtchen 240 505 4074 27 212 Living Room 322 2485 4957 131 258 Laundry 65 390 1066 20 55 Bed 151 1934 1628 102 85 Bed 175 2920 1716 154 89 D—'.N a0 coo caz 11 40 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. �- wrightsoP[" Ri9H-Su1eOLkiu rsa1201919.0.09RSL27054 t AC0' .-\WdgKwft HVACKad RoMnResder GromAo Calc=MJ8 Frorl Doorfacas: N 2019-A-16135330 Page 1 Hall Clst s0 16 U 0 V 0 V 0 0 Cond House d 2015 21917 22185 1153 1153 Other equip loads 1837 976 Equip. @ 0.95 RSM 22095 Latent000ling 7248 orncI oc�cc 2931? �1F3 1-153 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -Fri- wrightsoR" RigFkSub;®Umersa1201919.0.09 R$U27054 _\WogIIsoft HVACXad Rchan Resdero GromxW Calc=MJ8 From Coorfaoes: N 2019-11-1613:5390 Page2 Job: 698 Air Calcs,LLC Building Analysis Date: JuI16,2019 Cond House By. Vicki Lynne Barenberg Air Calcs, LLC 7550 HiddenHammock Lrl Vero Beach• FL32966 PIDre; 772,800.6413 Emai1:vlddVeQ°a1rca1mco,n Project Information For. Kad Rohan, Groza Builders, Inc 0 Shanas Trail, Port St Lucie, FL 34952 Design Conditions Location: Indoor: Heating Cooling St Lucie Co Intl, FL, US Indoor temperature (°F) 70 75 Hevation: 26 it Design TD (°F) 29 15 Latitude: 28°N Relative humidity (°/a)- 30 50 Outdoor. Heating Cooling Moisture difference (grAb) 2.4 56.9 Dry bulb (OF) 41 90 Infiltration: Daily range (OF) - 15 (L ) Method Simplified Wet bulb (°F) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Heating Component BtuhtF Btuh %of load Walls 2.8 4371 18.4 Glazing 8.7 1329 5.6 Doors 3.7 77 0.3 Ceilings 1.0 1990 8A Floors 2A 4761 20.0 Infiltration 2.1 2975 12.5 Ducts 6415 27.0 Piping 0 0 Humidification 0 0 Menfilation 1837 7.7 Adjustments 0 Total 1 1 237651 100.0 Cooling Component Btuhhj2 Btuh %of load Walls 1.5 2440 10.5 Glazing 15.8 2411 10A Doors 3.7 78 0.3 Ceilings 1.8 3623 15.6 Floors 0 0 0 Infiltration 0.6 790 3A Ducts 7167 30.9 Mentlation 976 4.2 Internal gains 5675 24.5 Blower 0 0 Adjustments 0 Total 23160 100.0 Latent Cooling Load =7248 Btuh Overall U-value = 0.075 BtuhIW2F Data entries checked. C1 Gains C # wrightsoft- 2019-JJ-16135330 �� Rgft-Sute0 Udversal 201919.0.09 RSU27054 Page 1 _\wdghoft HVAOXad Rohan Residence Groranp Calc=1418 FrortDoorhcesN ♦ JulC p Component Constructions Job: ' Air Calcs, LLC Date: ul 16, 2019 Cond House By. Vicki Lynne Barenberg Air Calcs, LLC 7550Hidden Hammock Lrk Vero Bead%FL32966PI M:772.800.8413 Email:viddlyme@airmismm irroject intormation For. Kari Rohan, Groza Builders, Inc 0 Shanas Trail, Port St Lucre, FL 34952 Design Conditions Indoor: Heating Cooling St Lucie Co Intl, FL, US Indoor temperature (=F) 70 75 Bevation: 26 it Design TD (=F) 29 15 Latitude: 28'N Relative humidity(%) 30 50 Outdoor:` Heating Cooling Moisture difference (grAb) 2A 56.9 Dry bulb (OF) 41 90 Infiltration: Daily range (OF) - 15 (L ) Method Simplified Wet bulb CF) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain R �F W13BG ehw 13 G euw 8G Walls 13A-7.5ocs: Blkwaa, stucco exf, r-9 ext bd ins, 8"thk 112"gypsum board ne 359 0.095 7.5 2.75 989 1.53 549 int fish as 236 0.095 7.5 2.76 651 1.53 362 sw 222 0.095 7.5 2.75 612 1.53 340 nw 411 0.095 7.5 2.75 1132 1.53 628 all 1228 0.095 7.5 2.76 3384 1.53 1879 Partitions 12B-0sw. Fnn wall, 112" gyp.bd ext, r-11 cav ins, 1/2"gypsum board int 351 0.097 11.0 2.81 987 1.60 561 fnsh, ZW" wood fan, 16" o.o. stud Windows Impact, Clear Low-E: Impact, Clear Low-E; NFRC rated (SHGC=0.20); ne 16 0.300 0 8.70 136 16.7 260 50% blinds 45", medium; 50% outdoor insect screen; foreground = green so 16 0.300 0 8.70 136 14.5 226 grass (0.23); 1.6 It overhang (5.2 ft window ht, 1 It sep.); 6.67 ft head ht sw 46 0.300 0 8.70 400 14.5 666 nw 16 0.300 0 8.70 136 16.7 260 all 93 0.300 0 8.70 807 15.2 1411 Impact, Clear Low-E: Impact, Clear Low-E; NFRC rated (SHGC=0.20); ne 52 0.300 0 8.70 452 16.7 866 50% binds 45', medium; 50% outdoor insect screen; foreground = green grass (0.23); 1.6 ft overhang (6.5 ft vdndow ht, 1 It sep.); 6.67 It head ht Impact, OBSC: Impact, OBSC; NFRC rated (SHGC=0.20); 50% blinds ne 4 0.300 0 8.70 35 16.7 67 45', medium; 50% outdoor insect screen; foregmund = green grass (0.23); 1.6 ft overhang (2 It window ht, 1 it sep.); 6.67 It head ht nw 4 0.300 0 8.70 35 16.7 67 a9 8 0.300 0 8.70 70 16.7 133 Doors Door, mtl fbrgl type sw 21 0.127 7.0 3.69 77 3.73 78 Ceilings Attic, asphalt shingles, r30 ce1 ins, 518" gypsum board int Irish 2015 0.034 30.0 0.99 1990 1.80 3623 Floors On grade depth; Tile flrfnsh 166 0.989 0 28.7 4761 0 0 2019111-19135130 Wrightsaft- .,.,.,., Rigk-Sute®Uriversal 201919.0.09 RSL27054 Page1 �'C'P` .-\WogttmftWAC%Ca4Rohan Re4tler Gromnp Calc=MI8 Frorl Doorlaces N _ Wrightsof , 2019-Ju-16135330 ..,,.., e...P., Rigk-SuteAUriwrsa1201919.0.09 RSU27054 Paget ��...\Wogtftoft FNACU(ad Rohan Redderc Grom+W Celc=MJ6 Frost Doorfams:N Project Summary Job: Air CalCs LLC 1 ry Jul Date: Ju116, 2019 Cond House By. Vicki Lynne Barenberg Air Calcs, LLC 7550HddenFlamm c4LmVero Bead�FL32966Phore:772.600.6413 Email: Nrkilyrne@aircal6.mm Project• • For. Karl Rohan Groza Builders, Inc 0 Shanas frail, Port St Lucie, FL 34952 Notes: Design • - Weather. St Lucie Co Intl, FL, US Winter Design Conditions Summer Design Conditions Outsidedb 41 OF Outsidedb 90 OF Insidedb 70 OF Insidedb 75 OF Design TO 29 OF DesignTD 15 OF Daily range L Relative humidity 50 % Moisture difference 57 grub Heating Summary Sensible Cooling Equipment Load Sizing Structure 15503 Btuh Structure 15017 Btuh Duds 6415 Btuh Duds 7167 Btuh Central vent (58 cfm) 1837 Btuh Central vent (58 cfm) 976 Btuh Outside air Outside air Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23755 Btuh Use manufacturer's data n Rate/swingg multipplier Equipmenisensibleload 0.95 22095 Btuh Infiltration Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2804 Btuh Ducts 2216 Btuh Central vent (58 cfm) 9998 Btuh Heatingg Coolingg Outside air 7248 Btuh Area(ftz) 2015 2015 Equipment latent load Volume (tta) 17502 17502 Airchanges/hour 0.32 0.16 Equipment Total Load (Sen+Lat) 29343 Btuh Equiv.AVF (cim) 93 47 Req. total capacity at 0.70 SHR 2.6 ton Heating Equipment Summary Cooling Equipment Summary Make Make Lennox Trade Trade LENNOX Model Cond 14ACXS036-230A * AHRI ref Coil CBA27UHE-036-230*++TDR AHRI ref 10259480 Efficiency 100 EFF Efficiency 13.0 EER,16 SEER Heatinglnput 6.6 kW Sensiblecooling 24220 Btuh Heating output 22457 Btuh Latent cooling 10380 Btuh Temperature rise 18 OF Total cooling 34600 Btuh Actual airflow 1153 cfm Actual airflow 1153 cfm Airflowfador 0.053 dfin/Btuh Airflow factor 0.052 cfmBtuh Static pressure 0.60 in H2O Static pressure 0.60 in H2O Space thermostat Load sensible heat ratio 0.76 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. _ -Fk- wrigM1ts f[' 2019-JJ-16135330 �� •--• Riglt-SUtgLiwrwi201919.0.09RSU27054 Page _\wigftwftFNAGXari Ronan Resderc Groranp Calc=MJB Frod Doortaoes:N Ait Calcs, LLC Right-JO Worksheet Job: 598 Cond House Data: Jul 16, 2019 By. Vicki Lynne Bamnberg Air Calcs, LLC 7550 Hidden Hammock Ln Vero Beach FL32966 Phore: 772b00.8413 Email: Nddlyme@aircalsmm 1 Room name Cond Ho Bath 2 Elpomdwall 166.0 It 23.5 it 3 Room height 8.7 it d 8.0 it heah'alol 4 Roomdimensims 11.5 x 6.5 R 5 Roomarea 2015.3 11' 74.8 18 Ty Conshucion U-VAM Or HTM Area (fte) Load Area in Load number (Blu"13- F) (BUM or perimeter (tq (Bbih) or perimeter (to (BWh) Heat Cool - Gross NIPS. Heat Cool Gras N/P/S Heat Cool 6 IINN 13A�7.5= - - 0.095 ne 2.75 1.53 431 359 .989 549 92 88 242 135 �--G Impact Clearl- vE 0.300 ne 8.70 16.66 16 0 136 260 0 0 0 0 It---GG Impact Clear La E 0.300 ne 8.70 16.68 52 0 452 866 0 0 0 0 Impact OBSC. _ -_ _ 0.300 .ne _ _ 8.70 16.66 -4 _ 0 --35 . _ _ _ 67 _ 4 _ 0 _ 35 67 11 _ W 13A-7.5ocs 0.095 se 275 1.53 252 236 651 362 48 48 132 73 1 Impact ClearL.E 0.300 se 8.70 14.49 16 5 _ 136 226 0 _ _ 0 _ 0 _ _0 W 13A-7.5= _ 0.095 w0 2.75 _ 1.53 _ _ 289 222 _ 612 340 0 0 6 Impact ClearicwE 0.300 sw 8.70 14A9 46 14 400 666 0 0 0 0 D Door, mtl brgl type _ _ 0.127 w „ 3.69 _ _ 3.73 21 _ 21 _ 77 78 0 _ 0 0 _ _ 0 WI 13A-7.5as 0.095 my 275 1.53 430 411 1132 628 48 48 132 73 - t-u Impact ClearLoxE 0.300 w 8.70 16.66 16 0 136 260 0 0 0 0 Impact OBSC 0.300 nw_ 8.70 16.66 4 0 35 67 -0 _ _ - 0 _ _,0 0 P - - 12B-0w 0.097 2.81 _- 1.60 _,_ 351 351 - .987 _ __ 561 0 0 0 0 - C _ Attioasphaltshing 0.034 0.99 1.80 2015 2015 1990 3623 75 _ 75 _ _ 74 134 F - _ OngradedeMtile 0.989 - _28.68 __ 0.00 _ 2015 _166 4761 ___ ,. 0 _ 75 24 674 0 6 c)AED e=Asim 0 -22 Envelopeloss/gain 12528 8553 1290 461 12 a) Irlfilt-Aon 2975 790 399 106 b) Roomwatlation 0 0 0 0 13 Interralgaim Oolpants@ 230 5 1150 0 0 Apptancesblher 4525 25 SublcWQines6t313) 15503 15017 1688 591 Lesse"cmalload 0 0 0 0 Lesstansfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 15503 15017 1688 591 15 Duct loads 41% 48% 6415 7167 41% 48% 699 282 Total rconl load 21917 22185 2387 874 Airrec;Wred(dm) 1153 1153 126 45 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed -F�F 2019Jd-1613:5390 A & •"'-' RigH-Sd1eO Uriversal 201919.0.09 RSU27054 Pagel _\Wdgksoft HJAC,Kad RoMnResdep Gromnp Calc=MJB Frort Doortaces: N 98 AiP Calcs, LLC Right-M) Worksheet Job: JulCond House Dale: ul 16, 2619 By. Vicki Lynne Barenberg Air Calcs, LLC 7550 Hdden Hanunodc Ln Vero Beads FL32966 P1nte: 772BOOB413 E=il:vtdalyme@a1malcs.mm 1 Room name Bed V*Clst 2 Exposadvall 19.0 a 0 ft 3 Room height 8.0 It heaV=l 8.0 It heaV=1 4 Rcam dimensions 1.0 x 198.3 ft 4.0 x 6.5 ft 5 Rwm area 193.3 W 26.0 IF Ty Construdon U-value Or HTM Area (n Load Area (M Load number (BhrMt-F) (BWINt') a perimeter (f4 (Bnrh) a PadmetBr (tQ (Btuh) Gross - N/P/S - Heat Cool Gross NrP/S Heat Cool 6 13A-7.5ocs 0.095 ne 2.75 133 40 40 110 61 0 0 0 0 Impact Clear 1-cwE 0.300 ne 8.70 16.66 0 0 0 0 0 0 0 0 Impact Clearl- wE 0.300 ne 8.70 16.66 0 0 0 0 0 0 0 0 Impact OBSC _ 0.300 ne- _ 8.70 16.66 _ _ 0 0 - _ C _ _ 0 . _ 0 _ _ 0 _ 0 _ _ _ 0 11 W 13A-7.5= 0.095 se Z75 1.53 0 0 0 0 0 0 0 0 Impact Clear LoµE se_ 8.70 14A9 0 0 -_ _ , _0 _ _ _ 0 �0 0 _ 0 _ _ _ 0 _ _ _0 W _ 13A-7.5as _ _0.300 0.095 sa _ 2.75 _ _ 1.53 0 __ _ 0 0 0 0 0 0 Impact ClearLauE 0.300 se 8.70 14.49 0 0 0 0 0 0 0 0 Dbor, m9 Nrgl type 0.127 taw _ 3.69 _ __-3.73 0 0 0 0 _0 _._. 0 _ 0 _ 0 W 13A-7.5= 0.095 rw Z75 1.53 112 96 266 147 0 0 0 0 E1I---� Impact ClearLowE 0.300 rw 8.70 16.66 16 0 136 260 0 0 0 0 - Impact OBSC 0.300 rw 8.70 16.66 - 0 - 0 _0 _ _ _ _ 0 10 _ . _ 0 ___ _ _ 0 ---0 P - - - 12B-Ow 0.097 - 2-81 1.60 _0 _- 0 0 _ _ 0 .__ 0 0 _ _ 0 _ 0 C _._ Agaasphaltshing 0.034 0.99 1.80 198 198 196 _ 356 _ _ 26 26 _ 25 _ _ _47 F Ongradedeplh, Tile _ 0.989 _ - _ 28.68 0.00 198 19 _ ,545 _ 0 26 0 0 0 61 c)AED emrrew 78 -2 Emelopelosygain 1252 903 26 45 12 a) Infiltration 323 86 0 0 b) Rcomwnfilation 0 0 0 0 13 Intemalgains Omrpants@ 230 0 0 0 0 Apprianceslother 200 0 SubtAgIQines6013) 1575 1189 25 45 Lemodernalload 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1575 1189 25 45 15 Dudloads 41% 48-A 652 567 41% 48% 11 22 Total mom load 2226 1756 36 67 Air required (dm) 117 91 2 3 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed -f}f wrigF,ttsoiS- 2019-A-1613:53.30 AC& -'�"^'• RigF Sdte®Uriversal 201919.0.09RSU27054 Paget ._1WAgtfsoftHVACVCed Rohan Resdeme Grownp Calc=MJB Frod Deorfaces:N 98 Air Calcs, LLC Right-M Worksheet Job: JulCond House, By-. Vicki Lynne Barenberg Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach FL32966 Phone: 772.8002413 Email:vicdlyme@aircalks.mm 1 Room name Master Bath WIC 2 Exposedvell 7.5 It 0 it 3 Room height 8.0 It heaVmol 8.o it heatlolol 4 Room dimensions 1.0 x 101.9 It 1.0 x 58.9 it 5 Roomarea 101.9 1158.9 ft Ty Construction U-value Or HTM Area W) Load Area QF) Load number (BtuhW-*F) (BtuhAP) a perimeter (f) (BWh) or perimeter (to (Bluh) Heat _ Cool Gros NIPS Heat Cod Gros WP5 Heat Cool _ 6 W 13A-7.5ocs 0.095 ne 275 1.53 0 0 0 0 0 0 0 0 Impact Clearl. wE 0.300 ne 8.70 16.66 0 0 0 0 0 0 0 0 Impact Clearl. + E 0.300 ne 8.70 16.66 0 0 0 0 0 0 0 0 Impact OBSC 0.300 ne 8.70 16.66 0 0 0 0 0 _ 0 0 0 11 W 13A-7.5as 0.095 se 275 1.53 0 0 0 0 0 0 0 0 I--C Impact Clearl- r E 0.300 s 8.70 1.4.49 0 0 0 0 0_ 0 - _0 0 W 13A-7.50 s 0.095 sv 275 1.53 0 0 _ 0 _ 0 0 0 0 0 Clear Lw}E 0.300 sH 8.70 14A9 0 0 0 0 0 0 0 0 LtImpact Door, mtl Porgl type 0.127 sv. 3.69 3.73 0 0 0 0 0 0 0 0 W 13A-7.5ccs 0.095 nw 275 1.53 60 56 154 86 0 0 0 0 LaImpact ClearLa E 0.300 nw 8.70 16.66 0 0 0 0 0 0 0 0 mpact OBSC 0.300 rw 8.70 16.66 4 0 _ 35 67 0 _ 0 _ 0 0 P 12BOw 0.097 - 281 1.60 0 0 0 0 0 0 0 0 C Atti4 asphaltshing 0.034 0.99 1.80 102 102 101 183 59 59 58 106 F On grade depth, Tile 0.989 - 28,68 0.00 102 8 215 0 59 0 0 0 6 c)AEDexanson 21 4 Enw1cpe loss/gain 505 357 58 102 12 a) Infiltration 127 34 0 0 b) Roomcentilation 0 0 0 0 13 Udemalgains O=pants@ 230 0 0 0 0 Appliances0+her 25 0 Subbtel Qines6to13) 632 415 58 102 Lesedemalload 0 0 0 0 Lestransfer 0 0 0 0 Redistribution 357 104 0 0 14 Subtotal 989 520 58 102 15 Dudloads 41% 481/6 409 248 41% 48% 24 49 Total room load 1398 1 768 a2 151 Air required(cfm) 74 40 4 8 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed wragFrrr�.soR- 2019-A14613:5350 iiCCP. •�'�^ RigtkSdteSUriwrsa1201919.0.09RSU27054 Page .-kWdgt 2HVACKad RahanResiden Grow.np Calc=W8 Frod Doorfaws:N Ait Calcs, LLC Right-JO Worksheet Job: 598 Cond House Date: Jul 16, 2019 By. Vicki Lynne Barenberg Air Calcs, LLC 7550 Hidden Hammock Ln Vero Bead1 FL32966 Plow: 772.80OB413 Email: dtldlynne@aircalcs.com 1 Room name Master Suite Dining Room 2 EVoseclMl 32-5 R 17.0 It 3 Room height 8.8 It heatl000l 9S 8 heaV=l 4 Room dimensons %5 x 18.0 It 17.0 x 12-0 It 5 Roomarea 261.0 re 204.0 V Ty Construction number U-1r4lue (BtuhAF-'9 Or HTM (BtuhM Area (fill or peimeter III Load (Btuh) Area (n or perimeter (fq Load (BWh) Heat Cod Gros NrPIS Heat Cod Gross NrP/S Heat. Cool 6 VjJ - Impack Clear LouE mpact, Cl, Impact Clear LowE 0300 0.300 0.300 M ne ne 275 8.70 8.70 1.63 16.66 16.66 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 W Impact, OBSC 134-7.5o s 0.300 0.095 ne se 8.70 275 16.66 1.53 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Impact CI.L.E 13A-7.5ors Impact Clearl. xE 0.300 0.095 0.300 w w 8.70 275 8.70 14A9 1.53 14.49 _ 0 128 23 0 105 7 0 288 200 0 160 333 0 162 23 _ 0 118 7 0 324 200 0 180 333 1W I--D Door,mllPorglype 13A-7.5ors 0.127 0.095 sw w 3.69 275 3.73 1.53 _ 0 158 0 158 0 436 0 242 21 0 21 0 77 0 78 0 w _ P Impart Clear Lw E Impact, OBSC _ 128-Ow 0.300 0.300 0.097 nw rw - 8.70 _ 8.70 281 16.66 16.66 1.60 0 0 .0 0 0 0 0 _ 0 0 0 0 0 0 0 114 0 _ 0 114 0 _ 0 321 0 _ 0 182 C AWgasphaltsling 0.034 - 0.99 1.80 261 261 258 469 204 204 201 367 F OngradedeptltTile i 0.989 - 28.68 0.00 251 33 932 0 204 17 _ 488 0 6 c) AED excurson 78 89 Ernelopel=bain 2114 12a3 1611 1229 12 a) Infiltraton 607 161 343 91 b) Roemeentlaton 0 0 0 0 13 Internal gains Omrpanb@ 230 0 0 0 0 ApplianoeJother 250 100 Subbfal Chase to 13) 2721 1694 1953 1420 LeseMemalload 0 0 0 0 Lemiansfer 0 0 0 0 Redistributon 99 29 0 0 14 Subtotal 2820 1723 1953 1420 15 Duo:loads 1167 822 41% 48% 808 678 Total room load 3987 2545 2762 2097 Air required (dm) 210 132 145 109 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed -F+k- wrag FitsoM1R- 2019Jd-16135330 PigF SLiLSUdwrwl201919.0.Og RSU27054 Page4 ....%WdgUwftWACKad Rohan Resideme GronAp Calc=MJB Frort Doorfaces:N Air Calcs, LLC Right-JO Worksheet Job: old MJul Cond House Date: By. Vicki Lynnneno Barenberg Air Calcs, LLC 7550 Ftidden Haarmck LR Vero Beads, FL32966 P1iore: 772.800.8413 Email: viddlyme@aircale.com 1 Room name Pantry IGtdten 2 Exposedvdi O ft O ft 3 Room height 9.5 ft hea7ocol 9.5 ft heaVoeol 4 Room dimensions 1.0 x 14.9 ft 1.0 x 240.1 it 5 Room area 14.9 ft 240.1 fF Ty Construction U-value Or HTM Area (ft) Load Area (in Load number (BWhAF-*9 (BWhAl) or perimeter (t (Bleh) or Perimeter m (Btuh) Heat I Cod Gross NIPS Heat I Cool Gross. WP/S. Heat I Cool 6% 13A-7.5or9 0.095 ne 275 1.53 0 0 0 0 0 0 0 0 �-G Impact Clearl- vE 0.300 ne 8.70 16.66 0 0 0 0 0 0 0. 0 Impact, Clear La E 0.300 ne, 8.70 16.66 0 0 0 0 0 0 0 0 L�--(f' Impact, OBSC _ 0.300 ne 8.70 16.66 _0 _ 0 0 0 0 _ 0 0 _ 0 11 _ W 13A-7.5oos 0.095 se 275 1.53 0 0 0 0 0 0 0 0 LG Impact Clear E 0.300 se 8.70 0 - 0 0 0 0 0 0 -0 _ __ 0 W _Lo _ 13A-7.5as 0.095 sx 275 __14A9 1.53 -0 _ _ 0 _ 0 _ 0 0 0 0 Clearl. r E 0.300 w 8.70 14A9 0 0 0 0 0 0 0 0 EtImpact, Docr, mil ftxgl type 0.127 sw 3.69 3.73 0 0 0 0 0 _ 0 0 -0 W 13A-7.5= 0.095 w 275 1.53 0 0 0 0 0 0 0 0 L-ts Impact Clear[-wE 0.300 my 8.70 16.66 0 0 0 0 0 0 0 0 G Impact OBSC 0.300 w 8.70 16.66 0 0 0 0 0 0 0 0 P 12B-Ow _ 0.097 - 2.81 1.60 38 38 107 61 43 43 120 68 C _ Alto asphalt sting 0.034 - 0.99 1.80 15 15 15 _ 27 240 240 _ 237 _432 IFOngradedepN,Tile 0.989 - 28.68 0.00 15 0 0 0 240 0 _0 0 6 c)AED exardon -3 1 -102 Emelopelosygain 122 84 357 398 12 a) Infiltration 0 0 0 0 b) Roomeenfilation 0 0 0 0 13 Intemalgains Oovpan6@ 230 0 0 2 460 Applianoesblher 0 1900 Subtotal Qines6to13) 122 84 357 2758 LesseAemalload 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Sublets! 122 84 357 2758 1151 Dudloads 41% 48% 50 40 41%, 48°/a 148A1316Total roomload 172 125505Airrequired(dm) 9 6 27 Calculations aooroved bvACCAto meet all requirements of Manual J 8th Ed -PLF wr]gbtsofe- 2019.14-16135330 ^'^^ Rigtt-Sute®Uive 1201919.0.09RSU27054 Pages -..\WhgnsoftWADKari Rohan Resderc GromxW Galt=Mde Frod Doorfaces N Air Calcs, LLC Right-JO Worksheet Job: Data: Jul Ju116, 2079 Cond House By. Vicki Lynne Barenberg Air Callas, LLC 7550Ftidden Hamnroee LRVero Bearh,FL32966Phore:772.800.8413 Emil: w$dtyme@aircaIscom 1 Roomname Uving Room Laundry 2 3 Expos ftell Room height 15.0 ft 9.5 It heatlmol 0 It 8.0 ft heatbod 4 5 Room dimensions Room area 1.0 x 322-0 ft 322.0 ft' 1.0 x 64.8 It 64.8 W Ty Construction U-value Or HTM Area 01* Load Area (M Load number (BtuhM;°F) (Blumn or perimeter (t) (Bluh) or perimeter (M (Btuh) Heat Cool Gross NIPS Heat Cool Gross NIPS Heat -- Cool 6 11 IW - 13A-7.5o s Imps Clearl- wE mpact Clearl- + E Impact, OBSC 13A-7.5as 0.095 0.300 0.300 0.300 0.095 ne no ne no se 2.75 8.70 8.70 8.70 275 1.53 16.66 16.66 16.66 1.53 143 0 52 _ 0 0 91 0 0 _ 0 0 249 0 452 - 0 0 138 - 0 866 - _ 0 '0 0 0 0 - 0 0 0 0 0 0 0 0 0 0 _ 0 0 0 0 0 _ 0 0 I--v LI-_GG fW c Impact Clear.t, wE 13A-7.5ocs _ Impact Clear -o E Door,mtilbrgl My 13A-7.5ocs Clear LouE Impact OBSC- 12B-Osm 0.300 _ _ 0.095 0.300 _ 0.127 0.095 0.300 0.300 0.097 se W sw sx M = my = _ _8.70 275 8.70 3.69 275 8.70 8.70 281 _ 14A9 1.53 14A9 - 3.73 1.53 16.66 16.66 1.60 0 _ __ _ 0 0 0 0 0 _0 0 0 0 0 0 0 0 0 - -0 0 _. _ __ 0 0 _ 0 0 0 0 - _ 0 0 __ _ _ 0 0 0 0 0 0 -0 0 0 0 0 0 0 0 -- -72 0 - _ 0 0 .0 0 0 0 , 72 0 0 0 0 0 0 _ 0 _ 203 0 - _0 0 0 0 0 _ 0 115 L_ W W 7:2Impact p- C _ Alto asphalt shine 0.034 - 0.99 1.80 322 322 318 579 65 65 64 116 - _ F On grade depth, Tile _ 0.989 - 2858 . 0.00 _ 322 15 _ 430 - - 0 _ 65 0 _ 0 0 6 o)AED exnuson -108 -26 EnWopeloss(gain 1450 1476 266 205 12 a) Infiltration 302 80 0 0 b) Roomeentilaton 0 0 0 0 13 Internal gains Omtpants@ 230 AyplianoeJolher 3 690 1100 0 0 500 Subotal Qin (ito13) 1752 3346 266 705 Lessedemal load 0 0 0 0 14 1151 LesstranAr Redistribution Subtotal Ducloads 41% 48% 0 6 1758 727 0 10 3356 1602 41% 48-A 0 9 276 114 0 16 721 344 Total mom load Airrequired(cm) 24a5 131 4957 258 390 20 1066 55 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -*- wrYgliLso-R� 2019JJ-16135390 ACCA Rigt4SJte4Dlhiwrsa1201919.0.09 RSU27054 Page 6 .-1WdgHsoftWAQKad Rohan Resdenr GromAp Calc=MJB Fron Doorfaces:N AR Caics, LLC Right -A) Worksheet Job: 598 Cond House Date: Jul 16, 2019 By Vicki Lynne Barenberg Air Calcs, LLC 7550 Hidden Hamnwd LR Vero Beads FL32966 Phore: 772.800.8413 Email: vitldlyrw@erraka.mm 1 Room name Bed3 Bed 2 3 Exposed vail Room height 13.0 It &0 ft beaV=l 26.5 ft 810 it heaYmol 4 5 Roomdimensions Room area 1.0 x 150,B ft 150.8 T 14.0 x 125 It 175.0 ft Ty Construction number U-value (BWhtrl'-'h) Or HTM (BtuhM Area In or perimeter (10 Lead (BWh) Area (ft1 or perimeter (f4 Load (Btuh) Heat Cool Gross WP/S Heat Cool Gross NfP/S. Heat Cool 6 11 WW �--G 13A-7.Socs I mpact ClearLouE Clear LouE Impact OBSC 13A-7.5ocs Impact CI.L.E 13A-7.5os Impact Clear LowE Door, ml lbrgl type 13A-7.5as Impact Clearl- vE mpact OBSC 12B-Ow Q095 0.300 0.300 _ 0.300 0.095 _ 0.300 0.095 0.300 .0.127 0.095 0.300 0.300 0.097 ne ne ne ne se m sw sw sw rrw rw mw - 275 8.70 8.70 8.70 275 8.70 275 8.70 3.69 275 &70 870 2.81 1.53 16.66 16.66 16.66 1.53 14A9 1.53 14A9 3.73 1.53 16.66 16.66 1.60 0 0 0 0 104 16 0 0 0 0 0 0 84 0 0 0 0 88 5 0 0 0 0 0 0 84 0 0 0 0 244 _ 136 0 0 0 0 0 0 236 0 0 0 0_ 135 _ 226 0 0 0 0 0 0 134 112 16 0 0 100 0 0 0 0 0 0 0 0 96 0 0 0 100 _ 0 0 0 0 0 0 0 0 266 136 0 0 275 0 0 0 0 0 0 0 0 147 260 0 0 153 _ 0 0 0 0 0 0 0 0 IEmpact, W W - IW P C Attigasphaltshinq 0.034 - 0.99 1.80 151 151 149 271 175 175 173 315 F On grade depff, Tile 0.989 - 2&6B 0.00 151 13 373 0 175 27 760 0 6 c)AED emirson 60 -43 Envelopeloss/gen 1137 826 1610 832 12 a) Infiltration 221 59 450 119 b) Roomwnfilation 0 0 0 0 13 Internal gairu: Cmrpants@ 230 0 0 0 0 App0anoWofher 200 200 Subtotal (lines6 to 13) 1358 1085 2059 1152 Leas odsmal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 10 17 6 10 14 Subbal 1368 1102 2065 1161 15 Ducloads 41% 48% 566 526 41% 48% 854 554 Total room load 1934 1628 2920 1716 Airrequired(dm) 102 85 154 89 Calculations aooroved bvACCAto meet all reauirementsof Manual J 8th Ed -F}F =r, gM1" so�it^- 2019-Jd-1613:5330 A & �"""�'^" � Right -Sate® Uiversal 201919.0.09 RSL27054 Page7 .AWngl1so8HVAQKad Rohan Reside" Gmmnp Calc=MJB FrortDoorfaces N Air Calcs, LLC Right-M Worksheet Job: 598 Cond House Date: Jul 16, 2019 By Vicki Lynne Barenberg Air Calcs, LLC 7550HiddenHammock LnVero Bead1FL32966P1ore:772200.8413 Email:ddd1yme@airnls.mm 1 Room name Bath Hall 2 EE4bsdvell 5.5 R 0 8 3 Room height 8.0 Itheatrmol 8.0 Itheatbool 4 Roomdimensions 5.5 x 125 ft 9.5 x 4.0 It 5 Roomarea 68.8 ft' 38.0 K Ty ConsWrSon U-value Or HTM Area (fP) Load Area Load number (Bhrwl F) (Btuhil) or perimeter (IQ (Bluh) or perimeter (ft) Ptuh) Heat Cod Grass NIPIS Heat Cool Gross NIPS Heat Cool 6 W 13A-7.5o s 0.0955 ne 275 1.53 44 44 121 67 0 0 0 0 Impact Clearl- vE 0.300 ne 8.70 16.66 0 0 0 0 0 0 0 0 Impact Clearl. + E 0.300 ne 8.70 16.66 0 0 0 0 0 0 0 0 Impact, OBSC 0300 no 8.70 16.66 0 0 0 0 0 0 0 0 11 13A-7.5o s 0.095 se 275 1.53 0 0 0 0 0 0 0 0 IW E--G Impact Clear Lp E 0.300 se -sv 8.70 14A9 0 "- 0 0 0 0 0 -0 - 0 0 w - 13A-7.5ocs 0.095 --275 - 1.53 0 - 0 0 0 0 0 0 Impact Clear cwE 0200 sw 8.70 14A9 0 0 0 0 0 0 0 0 Door,m8ftxgltype 0.127 av 3.69 3.73 0 0 0 0 0 0 0 0 13A-7.5ors 0.095 w 275 1.53 0 0 0 0 0 0 0 0 1W F-G Impact Clearl. rE 0,300 rnv 8.70 16.66 0 0 0 0 0 0 0 0 --C Impact OBSC 0.300 nw 8.70 16.66 0 0 0 0 0 0 0 0 P _ 12&OS 0.097 _ 2.81 1.60 _ _ _ - 0 0 0 0 _ 0 0 0 0 C Aticasphaltshing 0.034 - 0.99 1.80 69 69 68 124 38 38 _38 _68 F Ongradedepth, Tile 0.989 - 28.68 0.00 69 6 158 0 38 _ 0 0 0 6 c)AED elrolrsim -9 -2 Envelope loss/gain 347 182 38 66 12 a) Infiltraton 93 25 0 0 b) Roomventlation 0 0 0 0 13 Internal gains Oavparrts(g 230 0 0 0 0 Appliances'olher 25 0 Subbtaittnes6to13) 440 232 38 66 Lesse#emallood 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 8 13 J8 -66 14 Subtotal 448 245 0 0 15 Duct loads 41% 48% 18 5 117 41% 48% 0 0 Total room load 633 363 0 0 Airrecuired(Hm) 33 19 0 0 Calculations aoproved bvACCAto meet all requirements of Manual J Sth Ed -I&- wrigtitsoit- 2019JJ-1613:5330 "^"--^ RighYSdte®thiverse1201919A.09 RSU27054 PageB ACCk _%Wngthoft HVACXad Rohan ReddeniaGrozenp Calc=WB Frort Doorfaces:N Air Gales, LLC Right-M) Worksheet dab: ua Cond House Date: Jul 76, 2019 By. Vicki Lynne Baren6erg Air Gales, LLC 755014dden Hamm ck LRVero Bead5FL32966Ph m:772.800.8413 Email:viddlyme@airraIs.mm 1 Room name Clst 2 Elposadvall 6.5 ft 3 Room height 8.0 It hearlmol _ 4 Room dimensions 25 x 6.5 ft 5 Room area 16.3 If Ty Constuction U-value Or HTM Area (it) Load Area Load number (BtuhAl-*F) (Btuhll') or peimeter (tq (Bbh) or perimeter Heat Cool Gros WP/S Heat Cool Gross N/P/S Heat Cod 8 Vh13A-7.5ors 0.095 ne 275 1.53 0 0 0 0 Impact, ClearLauE 0.300 ne 8.70 16.66 0 0 0 0 Impact, Clearl- uE 0.300 ne 870 16.66 0 0 0 0 Impact OBSC 0.300 ne 8.70 _ _ 16.66 _ 0 0 0 _ 0 11 13A-7.5as 0.095 s 275 153 0 0 0 0 IW L-G impact Clear[- µE 0.300 se 8.70 "275 14.49 0 - 0 - 0 0 - -0 W 13A-7.5ocs 0.095 'm _ _ 1.53 _ _ 0 0 0 Impact ClearLouE 0.300 six 8.70 14A9 0 0 0 0 H. Door,m1trgltype - 0.127 sw 3.69 3.73 0 0 0 0 _ 13A-7.5o s 0.095 M275 1.53 52 52 143 80 fW pact Clear Lw+E 0.300 M 8.70 16.66 0 0 0 0 �_ G Im mpact OBSC 0.300 M 8.70 1.6.66 0 0 _ 0 - 0 _ P 12B-Ow 0.097 - 2.81 _ 1.60 _ 0 0 _ 0 0 C AWGasphaltshing 0.034 - 0.99 1.80 16 16 _ 16 29 F On grade depth, Tile 0.989 - 28.68 O.00 _ 16 7 _ 186 0 6 c)AED e)vurdon -5 Envelope losWgain 346 104 12 a) Infiltration 110 29 b) Roomventlation 0 0 13 Intamal gairm Oovpants@ 230 0 0 Appliance9otiler 0 Subblal Qines6b 13) 456 133 i'mexbmalload 0 0 Lestransfer 0 0 Reciffiibullon -456, -133 14 Subblal 0 0 15 Dudloads 41 % 48% 0 0 Total room load i 0 1 0 Airregdred(cfm) I 0 0 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -* w.rlghr�soTi� 2019.IJd613.53.10 ACCA FSgtiiSJle® Uriverml 201919.0.09 RSU27054 Page 9 ...\Wdghco8HVAC1Kad RohnResidence Gromxp Calc=MJB Frort DOoff429:N Manual S Compliance Report Job: 598 Air Calcs, LLC p p Date: Ju116.2019 Cond House By. Vicki Lynne Barenberg Air Calcs, LLC 7550 Hidden Hammock to Vero Beach, FL32966 Phore: 772.800.8413 Email: viddlyne@airoalcsmm Project Information For. Kad Rohan, Groza Builders, Inc 0 Shanas Trail, Port St Lucie, FL 34952 Cooling Equipment Design Conditions design DB: 90A°F Sensible gain: 23160 Btuh Entering coil DB: 76.9°F Outdoor design WB: 77A*F Latent gain: 7248 Btuh Entering coil WB: 64.1*F Indoor design DB: 75.0*F Total gain: 30408 Btuh IndoorRH: 50% Estimated airflow. 1153 cfrn Manufacturer's Performance Data atActual Design Conditions Equipment type: SplitAC Manufacturer. Lennox Model: 14ACXS036-230A**+CBA27UHE-036-230*++TDR Actual airflow. 1153 clam Sensible capacity: 24220 Btuh 105%ofload Latentcapaaty: 10380 Btuh 143%of load Total capacity: 34600 Btuh 114%ofload SHR: 70% Heating Equipment Design Conditions Outdoor design OR 41.07 Heatloss: 23755 Btuh Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: Manufacturer. Actual airflow. Output capacity: Hec strip Model: 1153 cfm 6.6 kW 95%of load Meets all requirements ofACCA Manual S. Entering coil DB: 68.0°F Temp. rise: 50 'F ti 4- wrightsoR" 2019-JJ-1613:5331 ^- ...., .....s., m-w. NgN-8utea Uriversal 201919.0.09 RSU27054 Pagel ACCA _\Wngibcft WACKan Rotan Residence Grom np Cale= MJ8 Froat Door faces: N �d, Job M 598 Performed by Vicki Lynne Barenberg for: Kari Rohan 0 Shanas Trail Port St Lucie, FL 34952 '! v � 42 in Air Caics, LLC 7550 Hidden Hammock Ln Vero Beach, FL 32966 Phone:772.800.8413 \ickilynne@aircaics.com Scale: 1 : 193 Page 1 Right -Suite® Universal 2019 19.0.09 RSU27054 2019,Jul-1613:53:56 ...Marl Rohan Residence Groza.rup