Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutFEDERAL ENGINEERING AND TESTINGG �F
r `1
ederal �.
ngineering
esting, Ine.1�T�
AM
Project: Pri
Address: 72
Area Tested:
Material Type:
Field Density Tests of Corn
Residence
Brown Sand with Some
FL 34952
0.ecravw
Phone: 964-784-2941
E-Fax: 954-784-7875
admin@fed-eng.com
www.fed-eng.com
D-6938
Date: December 4, 2019
Order M 19CMT3058
Permit #: SLa /QD F _ b1o33
Tech: AM
Client: Groza Builders, Inc.
Address: 511 SW Port St. Lucie Blvd. Compaction Req
Port St. Lucie, FL 34953 Proctor Method:
95%
ASTM D-1557
Test
#
TEST LOCATION
Probe
Depth
Elev.
Moist
%
Dry
Density
PCF
Proctor
Value
PCF
Optimum
Moisture
%
Compaction
Pass
1
NE Corner of Building Pad
12"
FL
6.7
114.7
115.0
11.0
99.7%
Yes
2
SE Corner of Building Pad
12"
FL
6.0
113.0
115.0
11.0
98.3%
Yes
3
SW Corner of Building Pad
12"
FL
6.8
114.2
115.0
1 11.0
99.3%
1 Yes
4
NW Corner of Building Pad
12"
FL
5.4
115.7
115.0
11.0
100.6%
Yes
5
6
7
8
9
10
11
12
13
14
Remarks: See Reverse Side (Page 2 of 2) for Additional Information for Disclaimer
This is a Compaction Test only on the top 12" of the pad and is not a verification of Soil Bearing Capacity.
Legend for Elevation:
PR = Proofroll 1,2,3 =1st, 2nd, 3rd Lift Submitted by: �rC
SL = Springline FL = Final Lift Keith LeBlanc,,P.E. (f f a
SG = Subgrade BG = Below Grade Federal Engirfeering &,Testing in . '
BC = Basecourse BOF = Bottom of Footing Florida Reg. No. 59394
TOP = Top of Pipe FG = Finished Grade Certificate of Authorization #-9471:
As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements,
conclusions or extracts from or regarding our reports is reserved pending our written approval. A density test determines the degrge of cempactiontof.the tested layer of
material only. A density does not replace a soil bearing capacity determination. These density tests do not certify the underlying soil material's below the, propo'sad structure.
The results do not preclude or guarantee that future settlement and cracking will not occur. A soil boring test is required to certify that the underiyingsols'wif support the
proposed structure without settlement. If no soil borings have been performed to verify the underlying soils, we recommend that soil borings be Iparfonned to evaluate the
suitability of the underlying soil to support the proposed structure. After laying dormant for a period of 90 days or after heavy mimstonns, retesting must be performed on this
work.
PAGE 1 of 2
Compacted Soils Method D-6938 Disclaimer
Pursuant to your request, Federal Engineering & Testing, Inc. (FET) has performed a compaction test at the referenced _
_project on the reverse side. The-purpose-of-our-test-was-to-determine-redegree o�on of the tested layer of
material only. In no way shall a compaction test replace a soil bearing capacity determination. A soil boring test must be
performed by the client prior to construction to verify subsoil conditions. Our scope of services only included testing the top
12" of added fill material. FET was not contracted to perform supervision of the building pad preparation. This testing of
the added fill material does not include an analysis of the underlying soil materials to determine if they are capable of
supporting the proposed structure without settlement. This density compaction test does not warranty any underlying soil
materials or conditions below the tested top 12 inches of material. If no soil borings have been performed in the location of
the proposed structure, we recommend performing soil borings below all foundation areas of the proposed structure to
verify the underlying soil conditions.
Environmental analysis of the soil materials is not part of the scope of services. If environmental analysis of the soils is
required, we can provide a proposal for performing an environmental analysis of the soil materials. The scope of services is
for determination of the degree of compaction of the tested layer of material only. No other analysis is implied or warranted.
Job project specifications were not available at the time the work was performed. Determination of the pass/fail compaction
results are based on current common industry requirements of 95% of the ASTM D-1557 standard for building foundations
and 98% of the AASHTO T-180 standard for paved areas such as roadways and parking lots. If different specifications are
required, Federal Engineering & Testing, Inc. shall be notified.
Our findings are relative to the date and areas of our site work and should not be relied upon to represent conditions on
other areas or dates. Any subsequent site disturbances due to water erosion, rain waters, construction activities, utility or
footing excavations, overgrown vegetation, traffic and other disturbances will void this test and the site must be re -
compacted and re -tested prior to construction.
As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of our client
and authorization for use, publication of statements, conclusions or extracts from or regarding our reports is reserved
pending our written approval.
It has been a pleasure working with you and we look forward to doing so in the near future.
9
Page 2 of 2
© ederal Phone:954784.2941
®-
O'. E-fax:".954-784-7875
ng�neer�ng - Q d-eng.ccm est�ng, Inc. - .. WWw.fed=eng:com
lorida 33_334
No: 200 Wash Sieve Analysis
Date: . Wednesday, December 4, 2019 Job Order Number 19CMT3058
Groza Builders, Inc.
511 SW Port, St. Lucie Blvd.
Port St. Lucie, FL 34953
RE-. ::Engineering Services
Proposed Residence
7204. Shanas.Trai1
Port St. Lucie, FL 34952
RESULT OF TESTS
Location: Building Pad . .
Sampled By: AM Reported To: Client
Sample Description: Brown Sand'witli Some Rock
Weight:_ 554.65. g
Tested By: S1(TIN # J32378081-.000)
Checked By: KL.
Respectfully Submitted,
-Keith LeBlanc,P.E:
Fe
deral Engineering & Testing, -Inc: ;
Florida Registration # 59394_
Certificate of Authorization..#}5471
IT;,fJo
ngineering.
,,Westing, Inc.
Phone 954-784 2941
E Fax 094 784-7875 .
admin@fed-eng corn .
www:fed-eng:corri -
3370 NE 5th Avenue Oakland Park, Florida 33334
PROCTOR COMPACTION TEST
DATE SAMPLED: 12/4/2019_ .. DATE TESTED: 12/6/2019 SAMPLE M 19CMT3058. .
CLIENT: Groza Builders, Inc.
ADDRESS: 511 SW Port St..Lucie Blvd.
PortSt. Lucie, .FL 34953 ..
PROJECT:. Proposed Residence .
LOCATION: 7204 Shanas Trail, Port St..Lucie,:FL 34952 - Sampled from Building Pad
MATERIAL DESCRIPTION: Brown Sand with Some Rock . MATERIAL M N/A
SAMPLED BY: AM TESTED BY: SJ . - TIN #: J32378081-000
SPECIFICATION GOVERNING: ASTM D-1557 LAB NO: 104035
RESULTS OF TEST:
The following compaction test was conducted in accordance with the Standard Methods of Moisture Density Relations of soil using a 10.lb. Hammer and
an 18" drop as perthe•above specified method.
MOISTURE % WET DENSITY (PCF) DRY DENSITY (PCF)
8.5 123.5 113.8.
10.3 . 126.7 114.9
12.4 129.0 114.8
13.8 129.4 113.7
115.2
115.0
114.8
U
114:6
y
'Vi 114.4
c
a
114.2
114.0
113.8
113.6
8 9 10 11 .12 13
Moisture (%).
14
Optimum Moisture (Percentage)
11.0
Maximum _Dry Density (lbs./cu. Ft.)
115.0 PCF
Respectfully Submitted,
Keith LeBlanc, P.E. 191
Federal Engineering & Testing,.lnc... '
Florida Reg. No 59394
Certificate of Authorization No. 5471
QCI AV ® .M FDOT
J l�