HomeMy WebLinkAboutARISTECH ACRYSTEEL PAPERWORK3 N
3 ,
TECHNICAL BULLETIN 148
PHYSICAL PROPERTIES—ARISTECH ACRYSTEELO IGP
Aristech Acrysteel IGP is a Continuous Cast Impact SCANNED
Acrylic Sheet with solvent cementability. BY
S$ 1..:-^-unf%,
The following physical properties were determined using 0.125" thickness dear Aristech Acrysteel IGP
Acrylic Sheet Properties may vary somewhat on other thicknesses and/or colors (translucent, transparent or
PROPERTY
TYPICALVALUE
UNITS
TESTMETHOD
Specific Gravity
1.17
—
ASTM D-792
OPTICAL
Refractive Index
1.49
—
ASTM DS42
Light Transmission
92.8
%
ASTM D-1003
Haze @ 75"F
2.5
%
ASTM D-1003
Yellowness Index
1.80
(0.125") YI
ASTM D-1925
2.00
(0.187") YI
2.20
(0.220") YI
MECHANICAL
Tensile Strength
7,400
psi
ASTM D-638
Tensile Modulus
364,000
psi
ASTM D-638
Flexural Strength
13,500
psi
ASTM D-790
Flexural Modulus
380,000
psi
ASTM D•790
Shear Strength
8.700
psi
ASTM D-732
Falling Dart Impact Strength
16 (0.187")
ft.lbs.
FTMS-406•M-1074 (Modified)
Charpy Impact Strength
11
ft.lbsJiin.
ASTM D-256
Hardness (Barcol)
40
—
ASTM D-2583
THERMAL
Hot Forming Temperature
Soak Temperature
One Side Infrared Heat
Heat Distortion Temperature
264 psi
Thermal Conductivity
Coefficient of Thermal
Expansion
Thermal Stability
(30 min. @ 356°F)
Flammability
Thermal Shrinkage
(Unrestrained)
MISCELLANEOUS
Water Absorption
Odor
Taste
Chemical Resistance
320-380
360-390
180° F
1.4
0.000042
No evidence
of Degradation
1.0
1.88
0.3
None
None
Similar to Aristech
GPA Acrylic
OF
OF
OF
BTU/hr. sq.ft. °F/ in.
in./ in. OF
in./ min
None
None
ARISTECH
ARISTECH
ASTM D-648
Cinco-Finch
ASTM D-696
L6�IbM.Lt:Ly.'
ASTM D-635
ASTM D-4802
ASTM D-570
Page 1
s�
J
ForcautionsandotherinformaHon rela6ngtohandlingofan
exposure tothisproduct, pleaseseetheapplicablematenal
safetydata sheet published byAristech.
These instructions are based upon experience with Aristech Acrylic products only. Experience with products of other
manufacturers is specifically disclaimed. For most uses, check for local code approval and test for application suitability.
These procedures, techniques and suggested materials should only be used by personnel who are property trained in
the safe handling of the chemicals and the equipment with which they are working. Avoid aromatic solvents, clean with
mild soap and water, avoid abrasives. These suggestions are based on information believed to be reliable, however,
Aristech Acrylics LLC makes no warranty, guarantee, or representation and ssumes no obligations or liability as to the
absolute correctness or sufficiency of any of the foregoing, or that additional or other measures may not be required under
particular conditions or circumstances.
„AYCH
ACRYLICS uc
7350 Empire Drive • Florence, KY 41042
(606) 283-1501 • Toll Free 8OD-354-9858
w .aristechacrylics.com
December 1998
Printed in USA
Aristech Acrylics LLC and Acrysteel
are registered trademarks.
Page 2
m5m
TWO FACES BLOWN OUT BY STORM
BLOWN OUT BY STORM
PARCEL ID# 1428.501-0022-000/5
ORIGINAL SIGN PERMIT #323090471
SCANNED
By
St. L"cip;vnimbf
ST. LUCIE COUNTY
BUILDING DIVISION
REVIEWED
FOR C PLI ICE
FIEVIEWED BY
DATE 'y
P NS AND PERMIT
MUST BE KEPT ON JOB OR
NO INSPECTION WILL BE MADE
ELEVATION
COULD SIGIVSN STUART PHONE (772)283-4666 -` SHELL FOOD MART
FAX (772)283-4704 ..9ss
3035 S.E. WHALER ST. STUART, FL 349971 TOLL FREE (866) 334-6853 2799 1.19 #1 HIGHWAY NORTH, FT. PIERCE 11/11/05