HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: DUANE & LINDA BOWMAN
Builder Name:
Itu
SURIBY
Street: 8202 LAKELAND BLVD.
Permit Office: ST. LUCIE COUNTY
per.
City, State, Zip: FT. PIERCE, FL,
Permit Number:
{� �
1. Lude County
St.
Omer. DUANE & LINDA BOWMAN
Jurisdiction: ST.LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1837.1 sqft.)
Insulation Area
2. Single family or multiple family Single-family
g y p y
a. Concrete Block - Ext Insul, Exterior
R=4.1 1638.00 ft2
b. Frame- Wood, Adjacent
R=11.0 199.11 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
10. Ceiling Types (1972.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=22.0 1972.00 ft2
6. Conditioned floor area above grade (ft2) 1972
b. NIA
R= ft2
Conditioned floor area below grade (ft2) 0
c. NIA
R= 2
11. Ducts
R ft2
7. Windows(254.6 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 175
a. U-Factor. SgI, U=0.65 206.57 ft2
SHGC: SHGC=0.25
b. U-Factor. SgI, U=0.65 48.00 11:2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.30
a. Central Unit
29.4 SEER:16.00
c. U-Factor. NIA ft2
'
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. NIA ft2
a. Electric Strip Heal
27.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 6.072 ft.
Area Weighted Average SHGC: 0.259
14. Hot water systems
a. Electric
Cap: 50 gallons
es 1972.0 soft.) Insulation Area
8. FloorTypes Yp (
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 1972.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.129 Total Proposed Modified Loads: 61.76
PASS
Total Baseline Loads: 65.63
1 hereby certify that the plans and specifications covered by
Review of the plans and
tcTKE S?qT
0
this calculation are in compliance with the Florida Energy
specifications covered by this
ti _ = FOK
Code.
calculation indicates compliance
yiib s,, o
with the Florida Energy Code.
a na„•.; • w==ps u O
PREPARED BY:
Before construction is completed
ce
DATE: .1 C1
this building will be inspected for
compliance with Section 553.908
0
I hereby certify that this builsliM as dt3i ned, is in compliance
Florida Statutes.
5C
COD
with the Florida Energy C e.
WE C¢�
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed In accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested In accordance with ANSIIRESNET/ICC 380, is not greater than 0.030 On for whole house.
8/15/2019 3:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) CompBan��otlt copy Page 1 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: DUANE & LINDA BOWMAN
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1972
Lot #
Owner Name: DUANE & LINDA BOWMAN
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
8202 LAKELAND BLVD
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: ST.LUCIE COUNTY
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
NewlEbsting: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name Area
Volume
1 Entire House 1972 18536.8
'
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1 MASTER BEDROO 252
2368.8 No
2
1
1
Yes
Yes
Yes
2 M. BATH 120
1128 No
0
1
Yes
Yes
Yes
3 LINEN 20
188 No
0
1
Yes
Yes
Yes
4 CLST. 112
1052.8 No
0
1
Yes
Yes
Yes
5 BEDROOM 3 168
1579.2 No
1
1
1
Yes
Yes
Yes
6 BATH 3 54
507.6 No
0
1
No
Yes
Yes
7 LIVING ROOM 358
3365.2 No
0
1
Yes
Yes
Yes
8 KITHCENIDINING 285
2679 Yes
2
1
Yes
Yes
Yes
9 BEDROOM 2 224
2105.6 No
1
1
1
Yes
Yes
Yes
10 BATH 2 134
1259.6 No
1
1
Yes
Yes
Yes
11 LIN 24
225.6 No
0
1
Yes
Yes
Yes
12 CLOSET 70
658 No
0
1
Yes
Yes
Yes
13 LAUNDRY 70
658 No
0
1
Yes
Yes
Yes
14 FOYER 81
761.4 No
0
1
Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio MASTER BEDRO 32 ft 0
252 fP
___
0 1
0
2 Slab -On -Grade Edge Insulatio
M. BATH Eft 0
120 ft'
_
0 1
0
3 Slab -On -Grade Edge Insulatio
LINEN 4 ft 0
20 ft'
0 1
0
4 Slab -On -Grade Edge Insulatio
CLST. 22 ft 0
112 ft'
—
0 1
0
8/15/2019 3:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
•:u :•r � I�Il�ji-��114h�/_1:TL�LTX�7:1�I=�i7�1�7:��
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
5 Slab -On -Grade Edge Insulatio
BEDROOM 3 22 ft
0
168 ft2
0
1
0
6 Slab -On -Grade Edge Insulatio
BATH 3 1 it
0
54 ft2
—
0
1
0
7 Slab -On -Grade Edge Insulatio
LIVING ROOM 18 ft
0
358 ft2
—
0
1
0
8SIab-On-Grade Edge Insulatio
KITHCEN/DININ 12 ft
0
285 ft2
—
0
1
0
9 Slab -On -Grade Edge Insulatio
BEDROOM 2 30 ft
0
224 ft2
—
0
1
0
16SIab-On-Grade Edge Insulatio
BATH 2 7 ft
0
134 ft'
a
0
1
0
l lSlab-On-Grade Edge Insulatio
LIN Eft
0
24 112
0
1
0
12SIab-On-Grade Edge Insulatio
CLOSET 7ft
0
70 112
_
0
1
0
13SIab-On-Grade Edge Insulatio
LAUNDRY Eft
0
70 ft2
0
1
0
14SIab-On-Grade Edge Insulatio
FOYER loft
0
81 ft2
—
0
1
0
ROOF
/
Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
V
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip
Metal 2136 ft2
0 ft2
Light
N
0.6
No 0.9
No 22
22.6
ATTIC
/
IRCC
V
# Type
Ventilation
Vent Ratio (1
in)
Area
RBS
1 Full attic
Unvented
0
1972 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
_
1 Under Attic (Unvented)
MASTER BEDRO
0
Blown
252 ft2
0.1
Wood
2 Under Attic (Unvented)
M. BATH
0
Blown
120 ft2
0.1
Wood
3 Under Attic (Unvented)
LINEN
0
Blown
20 ft2
0.1
Wood
4 Under Attic (Unvented)
CLST.
0
Blown
112 ft2
0.1
Wood
5 Under Attic (Unvented)
BEDROOM 3
0
Blown
168 ft2
0.1
Wood
6 Under Attic (Unvented)
BATH 3
0
Blown
54 ft2
0.1
Wood
7 Under Attic (Unvented)
LIVING ROOM
0
Blown
358 ft2
0.1
Wood
8 Under Attic (Unvented)
KITHCEN/DININ
0
Blown
285 ft2
0.1
Wood
9 Under Attic (Unvented)
BEDROOM 2
0
Blown
224 112
0.1
Wood
10 Under Attic (Unvented)
BATH
0
Blown
134 ft2
0.1
Wood
11 Under Attic (Unvented)
LIN
a
Blown
24 ft2
0.1
Wood
_
12 Under Attic (Unvented)
CLOSET
0
Blown
70 ft2
0.1
Wood
13 Under Attic (Unvented)
LAUNDRY
0
Blown
70 ft2
0.1
Wood
14 Under Attic (Unvented)
FOYER
0
Blown
81 ft2
0.1
Wood
8/15/2019 3:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
Below
Space
_ 1
N
Exterior
Concrete Block - Ext InaM4STER BE
4.1
14
0
9 0
126.0 ft2
0
0
0.6
0
-2
W
Exterior
Concrete Block - Ext InsliASTER BE
4.1
18
0
9 0
162.0 112
0
0
0.6
0
-3
W
Exterior
Concrete Block - Ext InsuM. BATH
4.1
6
0
9 0
54.0 ft2
0
0
0.6
0
-4
W
Exterior
Concrete Block - Ext Insul LINEN
4.1
4
0
9 0
36.0 fl2
0
0
0.6
0
_ 5
S
Exterior
Concrete Block - Ext Insul CLST.
4.1
14
0
9 0
126.0 112
0
0
0.6
0
_ 6
W
Exterior
Concrete Block - Ext Insul CLST.
4.1
8
0
9 0
72.0 ft2
0
0
0.6
0
7
E
Exterior
Concrete Block- Ext InMDROOM 3
4.1
8
0
9 D
72.0 ft2
0
0
0.6
0
_ 8
S
Exterior
Concrete Block - Ext InMDROOM 3
4.1
14
0
9 D
126.0 ft2
0
0
0.6
0
_ 9
N
Exterior
Concrete Block - Ext InddMING ROO
4.1
18
0
9 0
162.0 ft2
0
0
0.6
0
_ 10
N
Exterior
Concrete Block - Ext InsWITHCENIDI
4.1
12
0
9 0
108.0 ft2
0
0
0.6
0
_ 11
N
Exterior
Concrete Black - Ext InfiffDROOM 2
4.1
14
0
9 0
126.0 ft2
0
0
0.6
0
_ 12
E
Exterior
Concrete Block - Ext InfiffDROOM 2
4.1
16
0
9 0
144.0 R2
0
0
0.6
0
_ 13
E
Exterior
Concrete Block - Ext Insul BATH 2
4.1
7
0
9 0
63.0 ft2
0
0
0.6
0
14
N
Exterior
Concrete Block - Ext Insul LIN
4.1
1
0
9 0
9.0 ft2
0
0
0.6
0
_ 15
E
Exterior
Concrete Block - Ext Insul LIN
4.1
4
0
9 0
36.0 ft2
0
0
0.6
0
_ 16
S
Exterior
Concrete Block - Ext Insul LIN
4.1
1
0
9 0
9.0 ft2
0
0
0.6
0
_ 17
E
Exterior
Concrete Block - Ext Insu1CLOSET
4.1
7
0
9 0
63.0 ft2
0
0
0.6
0
_ 18
W
Exterior
Concrete Block- Ext InsdIAUNDRY
4.1
6
0
9 0
54.0 ft2
0
0
0.6
0
_ 19
S
Exterior
Concrete Block - Ext Insul FOYER
4.1
10
0
9 0
90.0 ft2
0
0
0.6
0
20
N
Garage
Frame - Wood FOYER
11
21
4
9 4
199.1 ft2
0
0.23 0.600000 0
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Omt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N 1
Metal Low-E Single Yes
0.65
0.25
N
32.9 ft2
2 ft 0 in
1 ft 4 in
None
None
2
W 3
Metal Low-E Single Yes
0.65
0.25
N
7.2 112
2 ft 0 in
1 ft4 in
None
None
3
S 5
Metal Low-E Single Yes
0.65
0.25
N
8.0 ft2
2 ft 0 in
1 ft 4 in
None
None
4
S 5
Metal Low-E Single Yes
0.65
0.25
N
4.2 ft2
2 ft 0 in
1 ft 4 in
None
None
_
5
S 8
Metal Low-E Single Yes
0.65
0.25
N
32.9 ft2
2 ft 0 in
1 ft 4 in
None
None
_
6
N 9
Metal Low-E Single Yes
0.65
0.3
N
24.0 ft2
10 ft 0 in
1114 in
None
None
_
7
N 9
Metal Low-E Single Yes
0.65
0.25
N
32.9 ft2
10 ft 0 in
1 ft 4 in
None
None
8
N 10
Metal Low-E Single Yes
0.65
0.25
N
32.7 ft2
10 ft 0 in
1 ft 4 in
None
None
9
N 11
Metal Low-E Single Yes
0.65
0.25
N
32.7 ft2
2 ft 0 in
1 ft 4 in
None
None
10
E 13
Metal Low-E Single Yes
0.65
0.25
N
7.2 ft2
2 ft 0 in
1 ft 4 in
None
None
11
S 19
Metal Low-E Single Yes
0.65
0.3
N
24.0 ft2
10 ft 0 in
1 ft 4 in
None
None
12
S 19
Metal Low-E Single Yes
0.65
0.25
N
16.0 ft2
10 ft 0 in
1 ft 4 in
None
None
8/15/2019 3:31 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
535 ft'
535 ft'
21.4 ft 9.4 ft 11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.000418
2162.6 118.73 223.28 .1545 7
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity Block
Ducts
1
Electric Strip Heat/
None
COP:1 27 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
Central UniU
Split
SEER: 16 29.4 kBtu/hr cfm 0.8 1
sys#1
HOT WATER SYSTEM
#
System Type SubTpe
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.95 50 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
ft'
DUCTS
#
LV
Supply —
Location R-Value Area
—Retum — Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT ON RLF
HVAC #
Heat Cooll
1
Attic 6 175 ft'
Attic
65 ft' Prop. Leak Free Attic — cfm 59.2 cfm 0.03 0.50
1 1
8/15/2019 3:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
R405 2017 INPUT SUMMARY CHECKLIST REPORT
FORM
TEMPERATURES
Programablre'Thermostat:
CFans:
�Y
HeDec
at InJan [%]
Feb
Mar
APIrreiling
JMay un
[[XX]]
I) Jul
[X]
E) Aug
fX]
Sep
[[ ]]
LJ OOcctt Nov
r[X']
Dec
Venting [[[ 111 Jan [II 111
l l
Feb
X Mar
Apr
[
May
Jun
l[ 11 Jul
) Aug
I[II 11 Sep
l
ll�xll
[ ]
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10 11
12
Cooling (WD)
80
80
78
78
78
78
78
78
78
80
78
78 76
78
PM
Cooling (WEH)
78
78
78
78
78
78
78
78
78
78 778 8
78
PM
Heating (WD)
68
68
68
68
68
68
68
B8
68
68 66
66
PM
Heating (WEH)
68
68
6B
68
68
68
68
68
68
68 66
66
PM
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 lbs/sq.ft.
0 fN
0 ft
0.3
MASTER BEDROO
Default(8 lbs/sq.ft.
ft'
ft
0.3
M. BATH
Default(8 lbs/sq.ft.
fl'
ft
0.3
LINEN
Default(8 lbs/sq.ft.
ft'
ft
0.3
CLST.
Default(8 Ibs/sq.ft.
ft'
ft
0.3
BEDROOM 3
Default(8 lbs/sq.ft.
ft'
ft
0.3
BATH 3
Default(8 lbs/sq.ft.
fl'
ft
0.3
LIVING ROOM
Default(8lbs/sq.ft.
ft'
ft
0.3
KITHCEN/DINING
Default(8 Ibs/sq.ft.
ft'
ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft'
ft
0.3
BATH 2
Default(8 lbs/sq.ft.
ft'
ft
0.3
LIN
Default(8 lbs/sq.ft.
ft'
ft
0.3
CLOSET
Default(8 lbs/sq.ft.
ft'
ft
0.3
LAUNDRY
Default(8 lbs/s.ft.
ft'
ft
0.3
FOYER
811512019 3:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: DUANE & LINDA BOWMAN Builder Name:
Street: 8202 LAKELAND BLVD. Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
U
Owner. DUANE & LINDA BOWMAN Jurisdiction: ST.LUCIE COUNTY
ul
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier,
not be used as a sealing material.
Breaks or joints In the air barier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barter.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed. -
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation,
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous Insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind Dinino and wirina.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. In addition, inspection of log walls shall be in accordance with the provisions of [CC-400.
8/15/2019 3:32 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 94
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
29.4
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEERICOP
6. Conditioned floor area (sq. ft.)
6.
1972
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.650
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.259
14. Heating system: Capacity
27.0
c) Area
7c.
254.6
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
" c) Concrete, raised (R-value)
90.
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
_ A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
0.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building
Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed^secj,qkJnstalled code compliant features.
Builder Signature: �V / Date: Ap �� / /
Address of New Home: 8202 LAKELAND BLVD. City/FL Zip: FT. PIERCE, FL
8/15/2019 3:31:52 PM EnergyGaugeO USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
-�+ wrightsoft- Project Summary Job:
:
Entire House By.
QUICK CALCS, INC.
317 ST. LUCIE LANE, FORE PIERCE, FL34946 P1ore:772466-6799 Emil: OLPCKCALCS@AOL.COM
For. DUANE& LINDA BOWMAN
8202 LAKELAND BLVD., FT. PIERCE,
Notes:
SEP 0 5 `V9
ST. Lucie County,
Weather. Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db
42
OF
Outsidedb
90
OF
Inside db
70
OF
Inside db
75
OF
Design TO
28
OF
DesignTD
15
OF
Daily range
M
Relative humidity
50
%
Moisture difference
61
grAb
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure
22115
Btuh
Structure
20112
Buh
Duds
3507
Btuh
Duds
2402
Btuh
Central vent (0 cfm)
0
Btuh
Central vent (0 dm)
0
Btuh
(none)
(none)
Humidification
0
Btuh
Blower
0
Btuh
Piping
0
Bluh
Equipmentload
25622
Btuh
Use manufacturer's data
n
Rate/swingI multipplier
Equipme load
0.95
21389
Stuh
Infiltration
I sensible
Method
simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
0
Structure
3980
BWh
1810
Central vent (0 cfm)
BBtuh
Heatingg
Coolingg
(none)
Area(ft2)
1972
1972
Equipment latent load
5798
Btuh
Volume ("
18527
18527
AirchangesAlour
0.38
0.20
Equipment Total Load Sen+Lat)
27187
Stuh
EquivAVF (cfm)
117
62
Req. total capacity at 0.70 SHR
2.5
ton
Heating Equipment Summary
Cooling Equipment Summary
Make
Make Carrier
Trade
Trade CARRIER
Model
Cond CA16NW03000GOA0
AHRI ref
Coil FX4DNF037L
AHRI ref 9201884
Efficiency
100
EFF
Efficiency 13.5 EER,16
SEER
Heating Input
7.1
kW
Sensible cooling
20580
Btuh
Heating output
24140
Btuh
Latent000ling
8820
Btuh
Temperature rise
50
OF
Total cooling
29400
Btuh
Actual airflow
439
cfrn
Actual airflow
980
cfm
Airflowfacor
0.017
cfm/Btuh
Airflowfactor
0.044
cfmlBtuh
Static pressure
0.50
in H2O
Static pressure
0.50
in H2O
Space thermostat
Load sensible heat ratio
0.80
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
wri9htsoft- 2019-At4-1515A1:43
^ �^ Wgl6Sute®Uriw=1201919.0.07R5U09101 Pagel
ACCk ^.mer4s\Wr1gtboftWACG0WMAN, DUANE&LINDAnp Calc=M78 FrorlDoarfaMs:8
H
OI
00000000�oNo�oov�o
�n�,
�
^o
�oo
�
000�m�
��
a
� '$
co
��
o0000000 �o �oNOO QQc�
^
�o
no
oomo �i
�n
UU
�
m m in 3m
H
1O
.�
e�im
e
� m
W �
mo
WMK
00000aoo,�o gioNoO cam
H
�
� �
....c
Z
N
m N
Ooo oo o o o-m'- O O N
N
N
OOO�s
O
b
1f`-1 fNV 1'n
mO
=
C
Z O
c yy�
AN
v.Erfi
OIn IONm pt7�Omfn NNlO fDmt��
n
f0
2
..:
mom min ago mmnm m -
mm`�5�����no
N606���,'pmNmN�Q
mo om m mm ggm 8m omm mm m0mmmmm�qm �q vmi �nm
N
Yn
OYIY fc����<�vmvihN �!`
{V
_
S
cggcvav vvm 33gg33-�
i
Qv
ppx
�Tl��i.�u �g7 �io
0em
d 06Ci0000000006000
F
QQ11
m 'sE
mm$$
._-fvJll��ovvo�v��vv��lllIVVVV
Mi5.9
llY�
0
F
v
le
pErn�
woo
GULL
h1
1
mA
W
N
11
m
0. �
C
..:....
TC) 9
ti
.11.op1op1 o]gogI .ogogll
6.
Hyy
�
�
A R
QQg 3.
6Siia
+�++
yAy yAy �+ yAy yAy yAy+�++A �++
�x�NN-{�-Wo"°M
g
m
SS..
m.
y
cc c ocv o'
ES3 GSi LSi LSi
cY'Ta
n
B
.W.
000505��000505��000505��50�00_00
��
pp�'�
+N.!n Sn,'mA(nA to,f+l�N UOIANA
ry2
min mmmomom minin0omc
mmYr�im moomommmmoomo
m
E=
o
$�
N
e
o
000a000J�m0000a000
o A
_
O
�
m O O O O O O JtAO'0 0 0 0 0 0 0 Oi
m
% G
a
O
mt0
m
A N 0 0
IN1
00
OI
.. Gfo 0 0 0 0 0 N V 0 0 0 0 0 0. 0.
O
S
V
#
A
W
W
+ +
om00000+m m00000000
o
o
00000000�"00000000.
3�
m
c A
�
u
�
o
e
A O O O O O O O Ol O O O O O O O O
A C
%
O Z
m
aZ
A
JN
bN000
N
OtJO
41
4 +N000000�+00000000
+
(Q
mfn
A a o O o
o
O O
O N
m
V
o 4f o 0 0 0 O O �O 0 0 0 0 0 o O
Elm
L7
7
0
R
t
OI
3
Y
ll
u�o�000m00000000 amo - .-
h
�
ono
o�c
�
oco��
�iS�
C
�v
om$oom�m0000000�Q� -
�
�o
�
000�P
��o
� N
i
O C
MAR '"
e
N
m m
�
h
Cv�
m m
�oN000�00000000'�
m
� igi
oo�oN c�oo'000000`o - - -
�
o
NO
oo
m
oaom�
�n
ac
c
$�
oomom u�000000000'o
Gi
�o
�
omo�g
g
��
(f' C
J O
p N X
O O OI Or O O n 0 0 0 0 0 0 N N - --
e
ZV
IIVV
N
Z
Q O
O O O m aT0 O m O 00 O O O N N -
O
e
mmmn�m6���N�$�S�o
cl �oN�mmamN�N�v m'��o
112--a
P4
a�v'm����a�vmnwN.-nN
a}
�
ccwvmmdv:mm3333�.�� _
m
d000d0000000dddo6
��
_ C73
55
E
pp p p p p p xpxp
N >IV NNN N iN NO�a'
C.p�
BN
ry
pry
���
>•
S S�S�a Ult
�NOIOm
m
m
N
N
vm
gelled S sae}iooOVwj efW=0190 du'VWJn934vna'NvnmoeovmuosmBNMI�au-
ERLY9L9l-BnV-6Gog to Ge0nSi1 LO'0'618lOZ lasianlYlalalPS-N6RJ
'P3 L49 f lenueW;o sluawajln aj Ile laaw of Voob q paAojdcle suoppoleC)
9"
99
E
Z
(wP)Paim6aenV
L9EE
Zen
99
66
Peol wow lelol
ME
Z"
-/ZL
%9L
L
4L
/Z
%9L
sPmlAna
9L
666Z
06LZ
89
98
pMnS
4L
0
0
0
0
wMq.uppaH
0
0
0
0
rtPua4ssal
0
0
0
0
PeollewaMassal
666Z
QSLZ
99
99
(£Lol96autopMnS
0
a
, W/smuellddv
0
0
0
0
oez @sjuedrm0 =m5pUm l
EL
0
0
a
o
ugelWa —H (q
lol
m
0
o
uogeym (e
ZL
868Z
Z64Z
99
98
uleblmoladopuG
89E1
E`
uo.Wm (13V(3
9
0
864
BL
BSE
0
0
0
49
00'0
691Z
-
6960
IdN1ZZ
d'
SOY
9%
SSE
BSE
L9
98
49
49
SVL
691
-
904'0
Iwo -UM
0-
0
0•
0
0
0
0 _
0
0
90'L
99Z
-
L800
NS"ZL
d
BZ9
Us
EE
EE
0
0
0
0
9V%
S99L
M
09So
goZStl4
0
0
0
0
0
0
0
0
LOZ4
899E
M
099'0
goZ5H4
ME
E04
LZ
4Z
0
0
0
0
6934
09'9L
M
009'0
A-90L
94Z
l94
Ell
6%
0
0
0
0
6LZ
0031
M
CoVo
smo lw
0
0
0
0
a'
0.
0.
0
9L'9L
899E
s
099'0
goZ5tl4
D--
0
0
0
0
0
0
0
0
6LZ
00'11
S.
E4L'o
MWWi
'MM
0
0
0
0
a
0
0
0
E9%
89'SL
a
099'0
goZitl4
0
0
0
0
0
0
0
0
LOZ4
899E
a
099'0
oZS14
0
0
0
0
a
0
0
0
96'9E
89'SL
a
099'0
goZSV40
HM
0
0
0
0
0
0
0
96'8E
999E
a
0990
goZSU40
0
0
0
0
0
0
0
69'4L
o991
a
009'0
a-9OL
0
0
0
0
0
0
0
0
6LZ
o0'q
a
CoVo
MDVWL
'
0
0
0
0
0
0
0.
0
%'M
899E
u
099'0
goZStl4
0-1
'
0
0
0'
0
0
0
0
0
6CZ
on
o
EFL'0.
s"4b'EL-
9
POO
IMH
S&N
s O
POO
W@H
SUN
sswO
Poo
WSH
i0
U-44r49)
ammA-n
jagwnu
W.PW o0
Al
(4N9)
Peal
(Y) iepwuad m
(dl) -N
(qne)
pem
(S) japwuad m
(A) easV
("[w)
W1H
aL o'99E
a P49
eat N
9
u 999E x of
a 0'9 x 0'6
swsuawlPu ld
4
po*m4 8 vs
8 09L
Pmhea4 8 4'6
U 0
146.64 uw l
IBav,P=*3
E
Z
WOOH ONVT
EHLV9
aweuwooy
L
W00'IOv@soivO>ionD:I1-3 6819-99q-ZLL auWd9469E1i 3Oi131d 1)iOd'3NVl3YJOl'1S LL£
:As
ONI 'so-wo N3U1b
:emu esnoH agjug
mor lea4smioM ®f'-346ia osay61�m }
+#�wrightsoft• Right-M Worksheet Job:
1
Entire House By.
QUICK CALCS, INC.
PCS o ceuARPMm-M9 S"MQ Fm 1110UICXCALCSr61AOL.COM
19THCENIDINING
BEDROOM2
1
Roan name
12.0 it
30.0 it
2
bposedxall
it 9A hwV=l
9A it heaVmd
3
Room
1.0 x 285.0 it
14.0 x 16.0 ft
4
Roomdimensions
285.0 T
224.0 fe
5
Room area
Ty
Construction
U-value
Or
HTM
Area Ve)
oPed � (14
Load
(Bh1h)
number
(BUhAtk-9
(BUhAt�
or pedmetr (M
(BWh)
Heat
Cod
Gross
NIPS
Heat
Cool
Gras
NIPS
Heat
Cod
6
IRJ
1MAM
0.143
n -
4.00
_ 2.19
0
0
0.
0
750
150
0
602
0
320
0
I--G
_
445*2ob
0.5m
n
15.68
16.16
0
0
0
0
0
0
0
0
0
13AAas
0.143
a
4.00
219
0
0
0
0
0
0
0
0
0
10B-v
0.600
a
16.80
14.69
0
0
0
0
0
0
0
11
4AS2ob
0.560
a
15.68
38.95
0
0
0
0
0
0
0
0
4AS2ob
0.560
a
15.68
38.95
0
0
0
0
0
0
0
0
0
4AS2ob
0.560
a
15.68
4207
0
0
0
0
0
0
6
4A5-2ob
0.560
a
15.68
19.63
0
0
0
0
'0
0
-0 !
0
yN
13A.4aIs
0.143
5
4.00
2.19
0 -
D
0
0
0
0
0'
0
00
L-G
gp£y2ob
O.Fi60
s
1566
16.16
219
0
113
0
80
321
175
130
89
396
216
13A-4o[s
0.143
w
4,00
0
0
0
0
0
0
0
10B-v
0.600
w
1620
14.59
0
0
0
0
33
2
512
1375
4AS2ab
0.560
w
1565
4207
0
528
0
0
0
0
4A5-2ob
0.660
w
15.68
16.16
33
33
612
0
0.
0
0
0
P
C
12C-0w
16X79-0mi
0.091
0.408
-
-
255
1.59
1.06
1.13
0
28.5
0
285
0
452
323
224
224
355
254
'.F
22A-to
0.988
27.69
-0.00
.• 265
12
332
0
224
30
531
0
750
554
6
c)AED e=rson
1617
1776
2697
2728
Envelope loss(gain
238
67
596
168
12
a) Irdil
0
0
0
0
h) Raammenlerltilatlon
13
htemal gains O=Pants@ 230
2
460
1
230
0
Apdiances6other
2000
1856
4304
3293
3126
Subtdal(lines6to 13)
0
0
0 0
Lee�malload
s
0 0
l.estran3er
p
p
0 0
RedittibLdon
1856
4304
3293
3126
14
Subbial
16%
12%
294
514
16%
12%
522
373
15
Dudloads
21f0
4818
3815
3500
Total room load
37
210
65
152
Airrecidred(Cm)
- wrl9ti�oTt-
RlghMiteO Unvemal 201919.0.07 RSU08101
-.menmwfigHwft HVA0BOWMAN, DUANE&UNDAAP Calc=MIS Frod Doorfa=8
2019-Ay1-1515A1A3
Page 5
n O N O O O O O O O N O O O O1� O
O
10
N O
O O
�
OO O W N
m m
Y m l0
Cl
m
L
JJJ
Q
b
vmi
b
o
Q
�
=
Z �
Q
J %
m
f0 O W O O O O O O O W O O O O Q m
t0 C!
a:
N
Om
Z
O O
N
E
Tc
m
N
m O
R O
g
O O O n
n m
m
U
_
9
C
aLa
N O O O O O O O O O O O O O N
W O
�1
O O O �I NQ
yy m
M
N
x�
Z
.8
Nd Nam R QN� Nm Nvvm��c
��
U
ommommmmo�oomm mW "'
O m O m m b b m0 O m b m b m m
o
N
Yn
Y�<fG^YI VSN Y�Q���N�1�
�govq
Eli
��ddd00000000000000
a
aas
td1 [d) x
O
'a'
0
N wcoQ
P"
F�aULL
u5
ma
N
m
Y m
�L
3
1
32
00000000R00000�i^o
mo
00
000�
`u3�
L
lea
oaooa000�p,o 0000��-$
N N �
p
r
mo
ty
m
000��
mm�
m
O
� n
U.
Z. %
�Id
o0000000a�00000��o
Yv
o
F
Z
a o
��
oom00000�0000 ono
of �
o o o m o o m o o 0000mno
at
.a0000000000000v
m
mo
n�
000r��
mm
0
0
r
ym
�
o
fO OOII
U
c
24
o
.o
ai o
E
�a000000aooaoo�or
m
m mmm uenmmmmmnm m ... ..
8
NiuN N
$
�:��o
�mmv�Nmr —V—o
�Q
5
m ommmmpm omm mm
o io8 moo mtOOd B�qm m6`{uy �o
=
�
S
O
CtCpmd
dyd�d�pdp NN{Q3�3(3p
d
Odd
�`R�m�OVi,�N.�um�,`$�R 0O Y.WN
�
o00000000oo o oocoo
a
`d
o 199 0 0 ;
>N NN�N/. N !N
'Q
� �
8
G
0�
a�
jLSJ��
U'c
Q o�Qd�. ��o�VH
evv e��
O
9�
S'
9K
a
pEJ
5}�7ax(
C�
� GULL
FF FF FF
SST wwxF
QS
C
W
Nd
I
J3Ka❑
FN
�y
wB
wrightscift• Right-J® Worksheet Job:
Entire House By.
By.
QUICK CALCS, INC.
317ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772-46M799 Emit: QUCKCALCS@AOL.COM
1
Roan name
FOYER
2
EVOWdvall
10.0 ft
3
Room height
9A 11 he8V000l
4
Roomdimerldons
1.0 x 81.0 It
5
Roan area
81.0 18
Ty
CwStumon
U-value
Or
HTM
Area (ft�
Load
Area
Load
number
(Btuh�T)
(BUW
or paimehr (fl)
(BWh)
or perimeter
Heat
Cod
Gross
NIPS
Heat
Cod
Gross
NIRS
Heat
Cab
6
IRJ -
13AA=
0.143
n
4.00
- 219
0
0
0
0
I--C
4A5-20b
0.560
n
15.68
16.16
0
0
0
0
13A-4=
0.143
a
4.00
2.19
94
64
216
118
11
10B-v
4AS20b
0.600
0.560
a
a
16.80
15.68
14.59
38.95
24
0
21
0
403
0
350
0
4A5-2ob
0.660
a
16.68
38.95
0
0
0
0
4A5-2ob
4A5-2ob
0.560
0.560
a
a
15.68
15.68
42-07
19.63
0
16
0
14
0
251
0
314
C
13A:4ors
0.143
s
4.00
2.19
0
a
0
0
4A5-lob
0.560.
s
15.68
16.16
0
0
'0
0
Vp/
13A4013-v
0.143
w
4.006
2.19
0
0
0
0
1
4A5-2ob
0.600
0.560
w
w
1.80
16.68
14.59
42.07
0
0
0
0
0
0
0
0
4A5-2ob
0,560
w
15.68
16.16
0
0
0
0
P
12C-OW
0.091
-
255
1,06
0
0
0
0
C
16X1940MI
0.408
-
1.59
1.13
81
81
128
92
F
22/4yl
-0.989
-
27.69
0.00
81
10
277
0
6
o)AED e=rslm
-51
Emelope losdgain
1276
823
12
a) Infilfiafm
199
56
b) Roomventlarfm
0
0
13
b0,arnal gains Oavpanfs@ 230
0
0
Applimceslother
0
Subtotal( lines6 to 13)
1474
879
L.essextomalload
0
0
Lesstransfer
0
0
Redistdbution
0
0
14
Subtotal
1474
879
15
Dudloads
16%
129/6
234
105
Total mom load
1708
984
Airrequ(red(dm)
29
43
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
_ -+}F- wrighesoie- 2019-Aug-1515AIA3
Rig"LitsOUriw ml201919D.07 RSU08101 Page 8
-mr1s\WdghtmRFNAC,80WMrW, DUANE&LIND" Calc=MJB Frort DoorfaasS
Duct S stem Summary Data:
wrightsoft y ry Date:
Entire House By.
QUICK CALCS, INC.
317 ST. LUCIE LANE, FORT PIERCE, FL34W Phore: 772-466-5799 Email: ONCKCALCS@AOL.COM
Project• •
For. DUANEBLINDABOWMAN
8202 LAKELAND BLVD., FT. PIERCE, FL34951
FAemal static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual airflow
Total effective length [TEL)
Heating
0.50
in H2O
0.28
in H2O
0.22
in H2O
0.110/0.110
in H2O
0.132
in/100ft
439
ckn
167
Supply Branch Detail Table
Cooling
0.50
in H2O
0.28
in H2O
0.22
in H2O
0.110/0.110
in H2O
0.132
in/100ft
980
ch
Name
Design
(Bluh)
mg
(Cl
CIg
MIMI
Design
FR
Diam
(in)
HxW
(in)
Duct
Mall
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BATH
c 703
18
31
0.269
5.0
Ox0
MFx
11.7
70.0
BATH
c 65
2
3
0.177
4.0
Ox0
V1Fx
34.5
90.0
SO
BEDROOM2
c 3500
65
152
0.185
7.0
OxO
VIFx
29.1
90.0
st2
BEDROOM3
c 2557
50
111
0.167
7.0
0x0
V1Fx
42.0
90.0
st1
CLOSET
h 1097
19
17
0.285
4.0
0x0
V1Fx
7.3
70.0
CLST.
c 1224
44
53
0.132
5.0
0x0
VIFx
57.1
110.0
st3
FOYER
C 984
29
43
0.166
5.0
Ox 0
V1Fx
42.4
90.0
st2
KITHCENIDIMNG
C 2409
18
105
0.177
7.0
OXO
MFx
34.1
90.0
st2
IMCENIDINING-A
c 2409
18
105
0.180
7.0
Ox0
MFx
32.5
90.0
st2
LAUNDRY
h 998
17
15
0.290
4.0
Ox0
ViFx
5.8
70.0
LIN
h 619
11
8
0.270
4.0
Ox 0
Wx
11 A
70.0
LINEN
h 432
7
6
0.134
4.0
Ox 0
Wx
53.9
110.0
st3
LIVING ROOM
c 3357
55
146
0.170
7.0
Ox0
V1Fx
39.7
90.0
st1
M. BATH
c 416
16
18
0.141
4.0
Ox0
V1Fx
46.3
110.0
st3
MASTERBEDROOM
c 3832
70
167
0.137
B.0
Ox0
MR
50.4
110.0
st3
Supply Trunk Detail Table
Trunk
Htg
Clg
Design
Veloc
Diam
HxW
Duct
Name
Type
(cfln)
(Cfin)
FR
(fpm)
(In)
(in)
Material
Trunk
sit
PeakAVF
243
504
0.132
642
12,0
0 x 0
VinIFlx
st3
PeakAVF
136
244
0.132
447
10.0
0 x 0
VinlFlx
st1
st2
PeakAVF
132
405
0.166
742
10.0
0 x 0
VinlFlx
Bold7talk values have been manually wenkl1on
wrightsof - 2019-P.y7-1515A1A4
• �.+-.o.,., RigM-StiL®Udaeraal201919.0A7R6U0B101 Pagel
..merls1Wrlgh9snaHVACBOWMAN, DUANEB LINDAnp Calo=MJS Fmrl Doorfa=S
Hlg
(cfm)
CIg
(C'g
TEL
(ft)
Design
FIR
Woc Diam
Qpm) (in)
HxW
(in)
Stud/Jois
Opening (in)
udt
Trunk
Grille
Sze (in)
Ox 0
439
9B0
0
0
0 0
Ox 0
\ Fx
2019-AUJ-1 515A1:44
wrigh[soft` Paget
.RigfESute®Uri�ersa1201919.OA7RSU08101
AM -m tXW4g9 ,.g VACBOWMAN, DUANE&LINDAnp Calc=MJB Fmrt Doorfaces S