HomeMy WebLinkAboutGENERAC GENERATOR PAPERWORKAutomatic Transfer Switches Description SCANNED GENE RAC® BY 4t.1 miprnllrw Service and non -Service rated Automatic Smart Transfer Switches 100 - 400 Amps, Single Phase PILE COPY SLLUCIE COUNTY PLAN REVIEW BLDG: DATE DATE:�01 PLUMB: DATE: MECH: DATE: C UL us LISTED *CUL only applies to non -service rated switches Generac Automatic Transfer Switches are designed for use with single phase generators that utilize an Evolution'" or Nexus"' Controller. The 100, 200, and 400 amp open transition switches are available in single phase in both service equipment rated and non -service equipment rated configurations. The 150 and 300 amp open transition switches are only available in a service rated equipment configuration. Standard Features Service rated (RXSW) Generac Automatic Transfer Switches are housed in an aluminum NEMA/UL Type 3R enclosure*, with electrostatically applied and baked powder paint. The Heavy Duty Generac Contactor is a UL recognized device, designed for years of service. The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands. All switches are covered by a 5 year limited warranty. * Non -service rated (RXSC) switches are housed in a steel enclosure. DPM Technology Through the use of digital power technology (DPM), these switches have the capability to manage up to 4 individual HVAC (24 VAC controlled) loads with no additional hardware. When used in tandem with Smart Management Modules, up to 8 more loads can be managed as well, providing the most installation efficient power management options available. • ISO200. GENERAC" 100-400 Amps, Single Phase Automatic Smart Transfer Switches Functions All timing and sensing functions originate in the generator controller Utilityvoltage drop-out......................................................................................................................................................................................................................<65% Timer to generator start .................................................................................................. 10 second factory set, adjustable between 2-1500 seconds by a qualified dealer" Enginewarm up delay................................................................................................................................................................................................................. 5 seconds Standbyvoltage sensor..................................................................................................................................................................................................65% for 5 seconds Utilityvoltage pickup.........................................................................................................................................................................................................................>80% Re -transfer time delay................................................................................................................................................................................................................15 seconds Enginecool -doom timer............................................................................................................................................................................................................ 60 seconds Exerciser..............................................................................................................................................................5 or 12 minutes adjustable weeklyBi-weekly/Monlhty.. The transfer switch can be operated manually without power applied. 'When used in conjunction with units utilizing Evolution- controls "Adjustable via the controller Specifications Model RXSC10OA3 RXSW1o0A3 RXSW150A3 RXSC20OA3 RXSW20OA3 RXSW300A3 RXSC40OA3 RXSW400A3 Amps 100 100 150 200 200 300 400 400 Voltage 120/240, 10 1201240, 10 120/240,10 120/240, 10 120/240,1e 120/240, to 120240, 10 120/240, 10 Load Transition Type (Automatic) Open Transition Open Transition Service Rated Open Transition Service Rated Open Transifion Open Transition Service Rated Open Transition Service Rated Open Transition Open Transition Service Rated Enclosure Type NEMA7UL 3R NEMA(UL3R NEMA/UL 3R NEMA/UL 3R NEMA(UL 313 NEMA(UL 3R NEMA/UL311 NEMAA)L 3R UL Rating UUCUL UL UL UUCUL UL UL UL/CUL UL Withstand Rating (Amps) 10,000 10,000 22,000 10,000 22,000 22,000 22,000 22,000 Lug Range 1/0-#14 250 MCM-#6 600 MCM-#4 or 1B-250 MCM Dimensions Model R)(SC100A3 RXSW1G0A3 RXSW150A3 RlLSC200A3 RXSW2D0A3 RXSW300A3 RXSC400A3 RXSW400A3 Height H1 17.24/437.9 1724/437.9 26.75/679.4 1724/437.9 26.75/679.4 42.91/1089.9 3125/793.8 4291/1089.9 (inJmm) H2 20/508 20/50B 30/762 20/508 30962 48/12192 361914A 4811219.2 Width W1 12.51317.5 12.51317.5 10.5266.7 12.5/3175 10.5266.7 16.69/423.9 19.18/4872 16.69/423.9 (inJmm) W2 14.6/370.8 14.61370.8 13.5/342.9 14.67370.8 13.5/342.9 21.82/554.2 24/609.6 21.82/554.2 Depth(in/mm) 7.09/180.1 7.09/180.1 6.3r160.1 7.09/180.1 6.M60.1 10.06255.5 10.06/255.5 10.06255.5 Weight(lbsAlos) 20/9.07 22.5r10.21 39/17.69 2019.07 39/17.69 14Qr63.5 133/60.33 140/63.5 !:l GEN ERAC' Generac Power Systems, Inc. • S45 W29290 HIM. 59, Waukesha, WI 53189 • generac.cdm 02017 Generac Power System, In. Aadgiftmewed. All specificatlma am subjectto chantiewithoutnotma, BuMtln10000013453A 0424/17 16/20/22 kW INCLUDES- • True Power" Electrical Technology FILE C®PY SCANNED BY Rt II►rio('nflntll, • Two Line LCD Multilingual Digital BLDG, Evolution'" Controller (English/Spanish/ DATE: French/Portuguese) FIE , • Two Transfer Switch Options Available: DATE: �-9 fl 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. PLUMB: See Page 4 for Details. DATE: • Electronic Governor MECH: • Standard wi-Fi' Remote Monitoring DATE • System Status & Maintenance Interval LED Indicators • Sound Attenuated Enclosure • Flexible Fuel Line Connector • Direct -To -Dirt Composite Mounting Pad • Natural Gas or LP Gas Operation • 5 Year Limited Warranty • Listed and Labeled by the Southwest Research Institute allowing installation as dose as 18" (457 mm) to a sWcture.- •Must be located away from doors, windows, and fresh air intakes and in accordance with local codes. hftps:llmets.swd.orgllibraryIDirectory0flistedProductsl Constructronlndustry1973_DoC_204_13204-01-01 Rev8.pd1 FEATURES GENERAC® GUARDIAN° SERIES Residential Standby Generators Air -Cooled Gas Engine Standby Power Rating Models G007036-1, G007037-1 (Aluminum - Bisque) -16 kW 60 Hz Model G007035-1 (Aluminum - Bisque) -16 kW 60 Hz Models G007039-1, G007038-1 (Aluminum -Bisque) - 20 kW 60 Hz Models G007043-2, G007042-2 (Aluminum - Bisque) -22 kW 60 Hz cl&s QUI� w"'�a Note: CUL certification only applies to unbundled units antl units packaged with limited circuit switches. Units packaged with the Sired Switch are UL cer ified in the USA only. O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING am at the head of Generates success in O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: providing the most reliable generators possible. Gemme s G-Force engine lineup offers added peace of mind and reliability for when you need it the most. The G-Force series engines are pur- This state-of-the-art power maximizing regulation system is standard on posebuilt and designed to handle the dgors of adended can times in high temperatures and V adreme operating conditions. load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1%. O TRUE POWER- ELECTRICAL TECHNOLOGY: Supedor harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's ehdenslve dealer form produce less than 5%Total Harmonic Distortion for utility quality power. This allows network provides parts and service know-how for the entire unit from Me confident operation of sensitive electronic equipment and micro -chip based appliances, engine to the smallest electronic component such as variable speed WAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are J PROTOTYPE TESTED d HEMA MG1-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this J SYSTEM TORSIONAL TESTED J MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. O MOBILE LINK- REMOTE MONITORING: FREE with every Guardian Series Home standby generator. Allows you to monitor the stabus of yourgeneratorfrorn anywhere in the wodd using a smartphbne, tablet, or PC. Easily access infor aUon such as the current `" 6 E N E R A C•� �, "� PROMISE operating static and maintenance sleds. Conned your account N your authored service _ dealer for fast friendly and proacgve service. With Mobile Link, you are taken care of before the neat power outage. GENERAC® 16/20/22 kW features and benefits Engine • Generac G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine ran cooler, reducing oil consumption resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/sparkadvance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to :1%prevents damaging voltage spikes. • UL2200listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers your Vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near your existing distribution panel forsimple, law -cost installation. Evolution— Controls • Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, ata-glance status indication in any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints 65%dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5seconds by a qualified dealer. • Engine wane -up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoinl approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" away from a building. GENERAC° 16/20/22 kW features and benefits Installation System • 1 R (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. • Direct -to -dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. • Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. Remote Monitoring • Ability to view generator status Monitor your generator via your smartyhone,tablet, or computer at any time via the Mobile Link application for complete peace of mind • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours • Ability to view generator maintenance information Provides maintenance information for your specific model generator when scheduled maintenance is due • Monthly report with previous month's activity. Detailed monthly reports provide historical generator information • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery • Weather information Provides detailed local ambient weather conditions for generator location 16/20/22 kW GENERACe specifications Generator Model 6007035-1, G0070364, G0070384, G0070394 0007042.2, G007043-2 [Hatetl AC Frequeng_ fi0-Fiz. 6U Fiz 66ftr'—"� Power Factor 1.0 1.0 1.0 Natural Gas - 8a/hr (ma/hr). } 1/2:Load _ - 218 (6.17) 204.(5.78) ,. 228 (6.46) 4t Full Load - 309 (6:75) 301 (8.52) 327 (9.26) Liquid Propane ft3/hr (gaYhr) [Vhr]. 1/2 Load 74 (2.03)1730] -': 87 (2.37) [8.99] --� 92 (2.53) [9.571 ' Full Load 101 (294)_(11111 130 (3.56) [73�48] 142 (390) [14`77D Note: Fuel pipe must fie sized M7lull hlad. Required fuel generator luel inlet at all load ranges-3.5-7-water column (7-13 mm mercury) for natural ps, 10-12' water column (19-22 mm mercury) zprew=to for LP ps. Far 810 comenL multiply Rs/hrx 2500 (LP) or 8 mr x 1000' ). For Meploule comer. multiply ma/hrx 93.15 (LP) orma/hr x3726 (NG) 'Bound Imisaet mbDmNetrontotmege r.SwdleMs6lalbmmlhadda Otftgerer nWbeNhOd@end gmi=latimpadn Patirgde5nidm5-Stm06/ApP1im 18MsupPlAngmrgmqpP fmlhedualion Pldreudliy poxzrmrtage Nomerhad myabilih7 kawilablabxmisregng. (All w ps in awadaxe with 655514. IS03046 aN OIN6271). ' Mannum Ailaualtampsaid omedare mblePtmadlimited bymrh tacblsazfiel6Wmepajwle owMambiedRmpeabde.dl We,eginepp ardcaW&n,m hlmemunpoaedeoesuab&A3.5pa tiorachl,OWfmipA.8metes)aEmm[east;adalmwillde abMIpamtbreach G'C(10°F)abwet6`C(60'0. GENERAC* 16/20/22 kW switch options Limited Circuits Switch Features • 16 space, 24 circuit, breakers not included. • Electrically operated, mechanically -held contacts for fast, positive connections • Rated for all classes of load, 100% equipment rated, both inductive and resistive. • 2-pole, 250 VAC contactors. • 30 millisecond transfer time. • Dual coil design. • Rated for both copper and aluminum conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 311 aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Multi listed for use with 18 standard, tandem, GFCI and AFCI breakers from Siemens, Murray, Eaton and Square D for the most flexible and cost effec- tive install. Dimensions Height Width Depth H7 H2 W1 W2 in 26.75 30.1 10.5 13.5 6.91 Min 679.4 764.3 266.7 343.0 175.4 Wire Ranges Conductor Lug Neutral Lug Ground Lug 1/0-#14 210-#14 2(0-#14 Service Rated Smart Switch Features • Includes Digital Power Management Technology standard (OPM). • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to four more large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load,100% equipment rated, both inductive and resis- tive. • 2-pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMAJUL 311 aluminum outdoor enclosure allows for indoor or outdoor mount- ing flexibility. Dimensions 200 Amps 1201240, to Open Transition Service Rated Height Width Depth HI H2 WI W2 In 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 343.0 175.4 Model G007036.1 (16kW) 1,10.01Poles _ 2 Current Rating (Amps) 100 Volage Rating (V C) UtilityValtage Monitor (Fuedil flrJwp -Dropout 80% 65% [Return to Utility' appra 15 sec Exercises hi -weekly for 5 minutes'1 Standard ULLIsted Slandaid Total Circuits Available 24 [Ea dtlem Breaker CagaCiliries - _ _ 6 tandems Circuit Breaker Protected Available RMS Symmebial Fault current @ 250 volts 10,000 *Functon of Evolution Controller Exercise can be set to weekly or monthly 1 Model G007037-1 (16 kM/0007039.1 (20 kW)/ 0007043.2 (22 kiln No: of Pole{. 2 Current Rating (Amps) 200 (Voltage Rating (VAC) Utility Voltage Monitor (Faed)• ,Rck,up 80% -nmuout 65% standard Lug Range 250 MCM -#6 *Function of Evolution Controller Exercise can be set to weekly or monthly 16/20/22 kW GENERAC available accessories Model # Product Description ` The Wi-FI enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Mon G007005-0 Wi-Fi LP Fuel Level Monitor honing the LP tanks fuel level is an important step In making sure your generator Is ready to run during an unexpected power failure. Status alerts are available through afree application to notify when your LP tank is in need of a refill. G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product (excluding PowerPact@). G007101-0 Battery Pad Warmer The pad warmer rests underthe battery. Recommended for use If the temperature regularlyfalls below OOF. (Not necessary for use with AGM -style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil fiber. Recommended for use If the temperature regulady falls below O'F G007103-1 Breather Warmer The breather wanner is for use in extreme cold weather applications. For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows me transfer Switch to lock out a single large electrical load Contact Kit you may not need. Not compatible with 50 amp pre -wired switches. Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a G007027-0 - Bisque (Standard on 22 kW) sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from G005703-0 - Bisque Paint kit future corrosion. The palm kh includes the necessary paimto property maintain or touch-up a generator enclosure. G006485-0 Scheduled Maintenance Kd Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. G006873-0 Smart Management Module Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its (50 Amps) power management capabilities. it provides additional powermanagememgexibility notfeund in any other power management system. dimensions & PCs Dimensions shmmam appmurtete. Reler ro ilatAlaomrrenazl for exact dimensions. DO NOT ME1HESE DIMENSIONS FOR INSTALLATION PURPOSES. I SIDEV1E V VA a" MCtffMEw Model UPC G007035-1 696471074161 G007036-1 696471074154 G007037-1 696471074178 G007038-1 696471074185 G007039-1 696471074192 G007042-2 696471074208 G007043-2 696471074215 GENE RAC® Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com 02018 Genera; Power Systems. Inc. M rights mewed. A] spec9eaaons are subtecl to changewbhoul nodes. Pao Na. 1000D000194-0 031I6/18