HomeMy WebLinkAboutGENERAC GENERATOR PAPERWORKAutomatic
Transfer Switches
Description
SCANNED GENE RAC®
BY
4t.1 miprnllrw Service and non -Service rated
Automatic Smart Transfer Switches
100 - 400 Amps, Single Phase
PILE COPY
SLLUCIE COUNTY
PLAN REVIEW
BLDG:
DATE
DATE:�01
PLUMB:
DATE:
MECH:
DATE:
C UL us
LISTED
*CUL only applies to non -service rated switches
Generac Automatic Transfer Switches are designed for use with single phase generators that utilize an Evolution'" or Nexus"'
Controller. The 100, 200, and 400 amp open transition switches are available in single phase in both service equipment rated and
non -service equipment rated configurations. The 150 and 300 amp open transition switches are only available in a service rated
equipment configuration.
Standard Features
Service rated (RXSW) Generac Automatic Transfer Switches are housed in an aluminum NEMA/UL Type 3R enclosure*, with
electrostatically applied and baked powder paint. The Heavy Duty Generac Contactor is a UL recognized device, designed for
years of service. The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands. All
switches are covered by a 5 year limited warranty.
* Non -service rated (RXSC) switches are housed in a steel enclosure.
DPM Technology
Through the use of digital power technology (DPM), these switches have the capability to manage up to 4 individual HVAC (24 VAC
controlled) loads with no additional hardware. When used in tandem with Smart Management Modules, up to 8 more loads can be
managed as well, providing the most installation efficient power management options available.
• ISO200.
GENERAC"
100-400 Amps, Single Phase Automatic Smart Transfer Switches
Functions
All timing and sensing functions originate in the generator controller
Utilityvoltage drop-out......................................................................................................................................................................................................................<65%
Timer to generator start ..................................................................................................
10 second factory set, adjustable between 2-1500 seconds by a qualified dealer"
Enginewarm up delay.................................................................................................................................................................................................................
5 seconds
Standbyvoltage sensor..................................................................................................................................................................................................65%
for 5 seconds
Utilityvoltage pickup.........................................................................................................................................................................................................................>80%
Re -transfer time delay................................................................................................................................................................................................................15
seconds
Enginecool -doom timer............................................................................................................................................................................................................
60 seconds
Exerciser..............................................................................................................................................................5
or 12 minutes adjustable weeklyBi-weekly/Monlhty..
The transfer switch can be operated manually without power applied.
'When used in conjunction with units utilizing Evolution- controls "Adjustable via the controller
Specifications
Model
RXSC10OA3
RXSW1o0A3
RXSW150A3
RXSC20OA3
RXSW20OA3
RXSW300A3
RXSC40OA3
RXSW400A3
Amps
100
100
150
200
200
300
400
400
Voltage
120/240, 10
1201240, 10
120/240,10
120/240, 10
120/240,1e
120/240, to
120240, 10
120/240, 10
Load Transition Type
(Automatic)
Open Transition
Open Transition
Service Rated
Open Transition
Service Rated
Open Transifion
Open Transition
Service Rated
Open Transition
Service Rated
Open Transition
Open Transition
Service Rated
Enclosure Type
NEMA7UL 3R
NEMA(UL3R
NEMA/UL 3R
NEMA/UL 3R
NEMA(UL 313
NEMA(UL 3R
NEMA/UL311
NEMAA)L 3R
UL Rating
UUCUL
UL
UL
UUCUL
UL
UL
UL/CUL
UL
Withstand Rating
(Amps)
10,000
10,000
22,000
10,000
22,000
22,000
22,000
22,000
Lug Range
1/0-#14
250 MCM-#6
600 MCM-#4 or 1B-250 MCM
Dimensions
Model
R)(SC100A3
RXSW1G0A3
RXSW150A3
RlLSC200A3
RXSW2D0A3
RXSW300A3
RXSC400A3
RXSW400A3
Height
H1
17.24/437.9
1724/437.9
26.75/679.4
1724/437.9
26.75/679.4
42.91/1089.9
3125/793.8
4291/1089.9
(inJmm)
H2
20/508
20/50B
30/762
20/508
30962
48/12192
361914A
4811219.2
Width
W1
12.51317.5
12.51317.5
10.5266.7
12.5/3175
10.5266.7
16.69/423.9
19.18/4872
16.69/423.9
(inJmm)
W2
14.6/370.8
14.61370.8
13.5/342.9
14.67370.8
13.5/342.9
21.82/554.2
24/609.6
21.82/554.2
Depth(in/mm)
7.09/180.1
7.09/180.1
6.3r160.1
7.09/180.1
6.M60.1
10.06255.5
10.06/255.5
10.06255.5
Weight(lbsAlos)
20/9.07
22.5r10.21
39/17.69
2019.07
39/17.69
14Qr63.5
133/60.33
140/63.5
!:l
GEN ERAC' Generac Power Systems, Inc. • S45 W29290 HIM. 59, Waukesha, WI 53189 • generac.cdm
02017 Generac Power System, In. Aadgiftmewed. All specificatlma am subjectto chantiewithoutnotma, BuMtln10000013453A 0424/17
16/20/22 kW
INCLUDES-
• True Power" Electrical Technology
FILE C®PY
SCANNED
BY
Rt II►rio('nflntll,
• Two Line LCD Multilingual Digital
BLDG,
Evolution'" Controller (English/Spanish/
DATE:
French/Portuguese)
FIE ,
• Two Transfer Switch Options Available:
DATE: �-9 fl
100 Amp, 16 Circuit Switch or
200 Amp Service Rated Smart Switch.
PLUMB:
See Page 4 for Details.
DATE:
• Electronic Governor
MECH:
• Standard wi-Fi' Remote Monitoring
DATE
• System Status & Maintenance Interval LED Indicators
• Sound Attenuated Enclosure
• Flexible Fuel Line Connector
• Direct -To -Dirt Composite Mounting Pad
• Natural Gas or LP Gas Operation
• 5 Year Limited Warranty
• Listed and Labeled by the Southwest Research Institute allowing
installation as dose as 18" (457 mm) to a sWcture.-
•Must be located away from doors, windows, and fresh air
intakes and in accordance with local codes.
hftps:llmets.swd.orgllibraryIDirectory0flistedProductsl
Constructronlndustry1973_DoC_204_13204-01-01 Rev8.pd1
FEATURES
GENERAC®
GUARDIAN° SERIES
Residential Standby Generators
Air -Cooled Gas Engine
Standby Power Rating
Models G007036-1, G007037-1 (Aluminum - Bisque) -16 kW 60 Hz
Model G007035-1 (Aluminum - Bisque) -16 kW 60 Hz
Models G007039-1, G007038-1 (Aluminum -Bisque) - 20 kW 60 Hz
Models G007043-2, G007042-2 (Aluminum - Bisque) -22 kW 60 Hz
cl&s QUI� w"'�a
Note: CUL certification only applies to unbundled units antl units packaged with
limited circuit switches. Units packaged with the Sired Switch are UL cer ified in
the USA only.
O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING am at the head of Generates success in
O
SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION:
providing the most reliable generators possible. Gemme s G-Force engine lineup offers added
peace of mind and reliability for when you need it the most. The G-Force series engines are pur-
This state-of-the-art power maximizing regulation system is standard on
posebuilt and designed to handle the dgors of adended can times in high temperatures and
V
adreme operating conditions.
load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
electronically torque -matching the surge loads to the engine. Digital
voltage regulation at ±1%.
O TRUE POWER- ELECTRICAL TECHNOLOGY: Supedor harmonics and sine wave
O
SINGLE SOURCE SERVICE RESPONSE from Generac's ehdenslve dealer
form produce less than 5%Total Harmonic Distortion for utility quality power. This allows
network provides parts and service know-how for the entire unit from Me
confident operation of sensitive electronic equipment and micro -chip based appliances,
engine to the smallest electronic component
such as variable speed WAC systems.
O TEST CRITERIA:
O
GENERAC TRANSFER SWITCHES: Long life and reliability are
J PROTOTYPE TESTED d HEMA MG1-22 EVALUATION
synonymous with GENERAC POWER SYSTEMS. One reason for this
J SYSTEM TORSIONAL TESTED J MOTOR STARTING ABILITY
confidence is that the GENERAC product line includes its own transfer
systems and controls for total system compatibility.
O MOBILE LINK- REMOTE MONITORING: FREE with every Guardian Series Home
standby generator. Allows you to monitor the stabus of yourgeneratorfrorn anywhere in the
wodd using a smartphbne, tablet, or PC. Easily access infor aUon such as the current
`"
6 E N E R A C•�
�, "�
PROMISE
operating static and maintenance sleds. Conned your account N your authored service
_
dealer for fast friendly and proacgve service. With Mobile Link, you are taken care of before
the neat power outage.
GENERAC®
16/20/22 kW
features and benefits
Engine
•
Generac G-Force design
Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly
rings helps the engine ran cooler, reducing oil consumption resulting in longer engine life.
•
"Spiny-lok" cast iron cylinder walls
Rigid construction and added durability provide long engine life.
•
Electronic ignition/sparkadvance
These features combine to assure smooth, quick starting every time.
•
Full pressure lubrication system
Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine
life. Now featuring up to a 2 year/200 hour oil change interval.
•
Low oil pressure shutdown system
Shutdown protection prevents catastrophic engine damage due to low oil.
•
High temperature shutdown
Prevents damage due to overheating.
Generator
•
Revolving field
Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature
generator.
•
Skewed stator
Produces a smooth output waveform for compatibility with electronic equipment.
•
Displaced phase excitation
Maximizes motor starting capability.
•
Automatic voltage regulation
Regulates the output voltage to :1%prevents damaging voltage spikes.
•
UL2200listed
For your safety.
Transfer Switch (if applicable)
•
Fully automatic
Transfers your Vital electrical loads to the energized source of power.
•
NEMA 3R
Can be installed inside or outside for maximum flexibility.
•
Remote mounting
Mounts near your existing distribution panel forsimple, law -cost installation.
Evolution— Controls
•
Auto/Manual/Off illuminated buttons
Selects the operating mode and provides easy, ata-glance status indication in any condition.
•
Two-line LCD multilingual display
Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences.
•
Sealed, raised buttons
Smooth, weather -resistant user interface for programming and operations.
•
Utility voltage sensing
Constantly monitors utility voltage, setpoints 65%dropout, 80% pick-up, of standard voltage.
•
Generator voltage sensing
Constantly monitors generator voltage to ensure the cleanest power delivered to the home.
•
Utility interrupt delay
Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of
5seconds by a qualified dealer.
•
Engine wane -up
Ensures engine is ready to assume the load, setpoint approximately 5 seconds.
•
Engine cool -down
Allows engine to cool prior to shutdown, setpoinl approximately 1 minute.
•
Programmable exercise
Operates engine to prevent oil seal drying and damage between power outages by running the generator
for 5 minutes every other week Also offers a selectable setting for weekly or monthly operation providing
flexibility and potentially lower fuel costs to the owner.
•
Smart battery charger
Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM -style batteries.
•
Main line circuit breaker
Protects generator from overload.
•
Electronic governor
Maintains constant 60 Hz frequency.
Unit
• SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding
winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine
maintenance items. Electrostatically applied textured epoxy paint for added durability.
• Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
• Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" away from a building.
GENERAC°
16/20/22 kW features and benefits
Installation System
• 1 R (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe.
• Direct -to -dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system.
• Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life.
Remote Monitoring
• Ability to view generator status Monitor your generator via your smartyhone,tablet, or computer at any time via the Mobile Link application for
complete peace of mind
• Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours
• Ability to view generator maintenance information Provides maintenance information for your specific model generator when scheduled maintenance is due
• Monthly report with previous month's activity. Detailed monthly reports provide historical generator information
• Ability to view generator battery information Built in battery diagnostics displaying current state of the battery
• Weather information Provides detailed local ambient weather conditions for generator location
16/20/22 kW
GENERACe
specifications
Generator
Model 6007035-1, G0070364, G0070384, G0070394 0007042.2, G007043-2
[Hatetl AC Frequeng_ fi0-Fiz. 6U Fiz 66ftr'—"�
Power Factor 1.0 1.0 1.0
Natural Gas - 8a/hr (ma/hr).
}
1/2:Load _
- 218 (6.17) 204.(5.78) ,.
228 (6.46) 4t
Full Load
- 309 (6:75) 301 (8.52)
327 (9.26)
Liquid Propane ft3/hr (gaYhr) [Vhr].
1/2 Load
74 (2.03)1730] -': 87 (2.37) [8.99] --�
92 (2.53) [9.571
' Full Load
101 (294)_(11111 130 (3.56) [73�48]
142 (390) [14`77D
Note: Fuel pipe must fie sized M7lull hlad. Required fuel generator luel inlet at all load ranges-3.5-7-water column (7-13 mm mercury) for natural ps, 10-12' water column (19-22 mm mercury)
zprew=to
for LP ps. Far 810 comenL multiply Rs/hrx 2500 (LP) or 8 mr x 1000'
). For Meploule comer. multiply ma/hrx 93.15 (LP) orma/hr x3726 (NG)
'Bound Imisaet mbDmNetrontotmege r.SwdleMs6lalbmmlhadda Otftgerer nWbeNhOd@end gmi=latimpadn Patirgde5nidm5-Stm06/ApP1im 18MsupPlAngmrgmqpP fmlhedualion
Pldreudliy poxzrmrtage Nomerhad myabilih7 kawilablabxmisregng. (All w ps in awadaxe with 655514. IS03046 aN OIN6271). ' Mannum Ailaualtampsaid omedare mblePtmadlimited bymrh tacblsazfiel6Wmepajwle
owMambiedRmpeabde.dl We,eginepp ardcaW&n,m hlmemunpoaedeoesuab&A3.5pa tiorachl,OWfmipA.8metes)aEmm[east;adalmwillde abMIpamtbreach G'C(10°F)abwet6`C(60'0.
GENERAC*
16/20/22 kW switch options
Limited Circuits Switch Features
• 16 space, 24 circuit, breakers not included.
• Electrically operated, mechanically -held contacts for fast, positive
connections
• Rated for all classes of load, 100% equipment rated, both inductive and
resistive.
• 2-pole, 250 VAC contactors.
• 30 millisecond transfer time.
• Dual coil design.
• Rated for both copper and aluminum conductors.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA/UL 311 aluminum outdoor enclosure allows for indoor or outdoor
mounting flexibility.
• Multi listed for use with 18 standard, tandem, GFCI and AFCI breakers from
Siemens, Murray, Eaton and Square D for the most flexible and cost effec-
tive install.
Dimensions
Height
Width
Depth
H7
H2
W1
W2
in
26.75
30.1
10.5
13.5
6.91
Min
679.4
764.3
266.7
343.0
175.4
Wire Ranges
Conductor Lug
Neutral Lug
Ground Lug
1/0-#14
210-#14
2(0-#14
Service Rated Smart Switch Features
• Includes Digital Power Management Technology standard (OPM).
• Intelligently manages up to four air conditioner loads with no additional
hardware.
• Up to four more large (240 VAC) loads can be managed when used in
conjunction with Smart Management Modules (SMMs).
• Electrically operated, mechanically -held contacts for fast, clean connections.
• Rated for all classes of load,100% equipment rated, both inductive and resis-
tive.
• 2-pole, 250 VAC contactors.
• Service equipment rated, dual coil design.
• Rated for both aluminum and copper conductors.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMAJUL 311 aluminum outdoor enclosure allows for indoor or outdoor mount-
ing flexibility.
Dimensions
200 Amps 1201240, to
Open Transition Service Rated
Height
Width
Depth
HI
H2
WI
W2
In
26.75
30.1
10.5
13.5
6.91
mm
679.4
764.3
266.7
343.0
175.4
Model
G007036.1 (16kW)
1,10.01Poles _
2
Current Rating (Amps)
100
Volage Rating (V C)
UtilityValtage Monitor (Fuedil
flrJwp
-Dropout
80%
65%
[Return to Utility'
appra 15 sec
Exercises hi -weekly for 5 minutes'1
Standard
ULLIsted
Slandaid
Total Circuits Available
24
[Ea dtlem Breaker CagaCiliries -
_ _ 6 tandems
Circuit Breaker Protected
Available RMS Symmebial
Fault current @ 250 volts
10,000
*Functon of Evolution Controller
Exercise can be set to weekly or monthly
1
Model
G007037-1 (16 kM/0007039.1 (20 kW)/
0007043.2 (22 kiln
No: of Pole{.
2
Current Rating (Amps)
200
(Voltage Rating (VAC)
Utility Voltage Monitor (Faed)•
,Rck,up
80%
-nmuout
65%
standard
Lug Range 250 MCM -#6
*Function of Evolution Controller
Exercise can be set to weekly or monthly
16/20/22 kW
GENERAC
available accessories
Model # Product Description `
The Wi-FI enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Mon
G007005-0
Wi-Fi LP Fuel Level Monitor
honing the LP tanks fuel level is an important step In making sure your generator Is ready to run during an
unexpected power failure. Status alerts are available through afree application to notify when your LP tank
is in need of a refill.
G005819-0
26R Wet Cell Battery
Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet
cell battery for use with all air-cooled standby product (excluding PowerPact@).
G007101-0
Battery Pad Warmer
The pad warmer rests underthe battery. Recommended for use If the temperature regularlyfalls below OOF.
(Not necessary for use with AGM -style batteries).
G007102-0
Oil Warmer
Oil warmer slips directly over the oil fiber. Recommended for use If the temperature regulady falls below O'F
G007103-1
Breather Warmer
The breather wanner is for use in extreme cold weather applications. For use with Evolution controllers
only in climates where heavy icing occurs.
G005621-0
Auxiliary Transfer Switch
The auxiliary transfer switch contact kit allows me transfer Switch to lock out a single large electrical load
Contact Kit
you may not need. Not compatible with 50 amp pre -wired switches.
Fascia Base Wrap Kit
The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a
G007027-0 - Bisque
(Standard on 22 kW)
sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting
holes located in the base.
If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from
G005703-0 - Bisque
Paint kit
future corrosion. The palm kh includes the necessary paimto property maintain or touch-up a generator
enclosure.
G006485-0
Scheduled Maintenance Kd
Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine
maintenance on a Generac automatic standby generator.
G006873-0
Smart Management Module
Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its
(50 Amps)
power management capabilities. it provides additional powermanagememgexibility notfeund in any other
power management system.
dimensions & PCs
Dimensions shmmam appmurtete. Reler ro ilatAlaomrrenazl for exact dimensions. DO NOT ME1HESE DIMENSIONS FOR INSTALLATION PURPOSES.
I SIDEV1E V
VA a"
MCtffMEw
Model
UPC
G007035-1
696471074161
G007036-1
696471074154
G007037-1
696471074178
G007038-1
696471074185
G007039-1
696471074192
G007042-2
696471074208
G007043-2
696471074215
GENE RAC® Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com
02018 Genera; Power Systems. Inc. M rights mewed. A] spec9eaaons are subtecl to changewbhoul nodes. Pao Na. 1000D000194-0 031I6/18