Loading...
HomeMy WebLinkAboutGAS PIPING SCHEMATICBOARD OF COUNTY COMMISSIONERS GAS PIPING SCHEMATIC TANK SIZE: 45CO GALS. PtrrLIl+A14VC— 1 irCh71LG Ai LQ(2a h1A�" herrNtc L -a BTU A2 nq Y, BTU QIQ C Q A4 VDV1 BTU AS-1 Gn5S ICV� Y-) BTU A6 BTU PIPING LENGTH & SIZE L1AD FT. WLV INCH DIA. L2 1%Q) FT. 1" INCH DIA. L3 Pb FT. ` " INCH DIA. L4 FT. INCH DIA. L5 FT. INCH DIA. L6 FT. INCH DIA. L7 FT. INCH DIA. L8 FT. INCH DIA. L9 FT. INCH DIA. L10 FT. INCH DIA. 1_11 FT. INCH DIA. L12 FT. INCH DIA. Revised 7/22/14 PLANNING & DEVELOPMENT SERVICES DEPARTMENT Building and Code Regulation Division 'SCANNED BY % LUCiP ilminfi (PIPE SIZE WAS TAKEN FROM THE 2014 FBC FUEL GAS CODE - TABLE 402 (_mil Website: www stlucieco.aov 2300 Virginia Avenue - Fort Pierce, FL. 34982-5652 Phone (772)462-1553 FAX (772)462-1578 - aty mrtnpemwnu.w.+�wnen Penmmonwwrrn. rw'mgwreswwayw.ww� ® Chapler l5 • Plp6 ...J Tubing Sizing Tables TABLE 15.I(o) Polyetkylene Plastiic.Pipe Sa �B°h First Stage and Second -Stage Regulators: Nominal Outside Diameter (IP4 Ctrs: I Undllutedpmpane SCANNED InktPressure: . IO.Opsi Preasare Drop: Mpg! Grov p BY St. LUdeft Io 1perifia i(y: IS2 Plaa'tic — — I% in Z'/_um tin. Pipe 'S m«°Z - I SDR lO.OQ SDR I1,00 SDR 1I.00 02 Length SDR 9.33 SDI SDR 171 13281554 I943) (R) (0.660) (6,860) lI•Q 1- ) (• ) f 30` 214.1 ¢`29 7744 11416 1734D 36402 40 1835 3671 6628 11482 17340 31155 50 1626 3256 5874 10176 15368 27612 60 1473 2950 5322 922_0 13924 25019 70 1355 2714 4896 8493 12810 23017 261 2525 4555 7891 11918 21413 193 BO 1 90 1261 2525 4274 7404 11182 20D91 8972 100 1117 2118 40-17 6194 19361 16820 125 990 1983 3579 5616 9361 16820 150 897 1797 3342 5616 8482 ]5244 175 826 1653 2983 51 67 78 0 3 13UI 225 71-1 144.3 2603 45102238 6811 1560 250 691 1363 2459 4260 (434 11560 275 646 1244 2336 4046 6111 10979 300 617 1235 2229 3860 5630 10474 350 567 1136 2050 3551 5363 9636 400 528 1057 1907 3304 4989 8965 �50 495 992 1789 3100 4691 8411 500 468 937 1690 2928 4422 7945 424 849 1531 2653 4007 7199 600 0390 781 1409 2441 3686 6623 363 726 1311 2271 3429 6161 90D00 31230 2131 3217 5791 1000 322 644 1162 2012 3039 '5461 0 253 517 . 933 1616 2441 4385 C0 �00 22] 443 798 1383 ^_084 3753 IPS: Imn pipe size. SDR Standard dimension Tana. Notes: (1) Capacities are in 1000 Boaft (21 Dimensions in Pa Ei`eses are inside dismetar. / """"JaFlW 36 Y II M'f 1pI1�Bd9Nl ON HO Bor No 14i3N 391SI1w Llwu9ci Glqv SNVId 911 31vc A8 031MMA3i: i 300 !!Od NOISIAIO ON10 ine ALNrl00 313M 1S y 2014 LP -Gat Code Handbook V.V. CABLE Wj CLAMPS TO (PULLED ANCHOR STRAP (2) LAYERS OF FELT BETWEEN STRAP AND (2)HDG CLAMPS TO ANCHOR (PULLED - TIGHT) UNDERGROUND TANK HOLD DOWN DETAIL GENERAL NOTES: 1. HELICAL ANCHORS SHALL HAVE AN ALLOWABLE PULL-OUT CAPACITY AS SHOWN BELOW. ANCHORS SHALL BE INSTALLED PER ANCHOR R(,NOFAbTURER.T0 ACHIEVE STATED LOAD CAPACITY. CAPACITY VARIES WITH SOIL TYPE, VERIFY ANCHOR CAPACITY WITH SOIL 7Y0'E.iWCOL)fJTERED:i c,. .. 'CHECK 6COARRGRISUND.`URLRIES PRIOR TO ANCHOR INSTALLATIDN `LOCATION TANK RELATIVEg70 ADJACENT STRUCTURES AND FEATURES ARE DEPENDENT UPON LOCAL CODES AND IS THE PONSIBIUTY OF OTHERS. ! '[ THE TANK .AS SHOWN HAS. BEEN DESIGNED TO PREVENT FLOTATION. COLLAPSE. OR LATERAL MOVEMENT DURING THE BASE )D.,EVENT" n - 0 COPYRIGHT 2016 — FARLEY ENGINEERING. LLC i PA DAT I AMERIGAS Consulting Engineer #40111 — CA28108 wui sfi, Qua, ) Steel Corporation AG/UG Pro ie Tanks ' LE, MIOT� 1450 vary. AND UP APPROXIMATE ABOVEGROUND/UNDEGROUND'(AG/UG) VESSEL DIMENSIONS AND SPECIFICATIONS WATER CAPACITY DIAMETER (OD) HEAD TYPE OVERALL LENGTH OVERALL HEIGHT , LEG* WIDTH LEG** "SPACING WEIGHT (lbs.) **QUANTITY FULLLogD PERSTACK *120 wg. 24" Ellip. 5'-8" 3' V-11/2" 2 101/2' or T-11" 260 108 ) 96 161 12 *250 wg. 30" Hemi. 7'40" 3'-8" 11-5" 4'-11" 480 54 9 *320 wg_ 3011 Hemi. 9'-7" 3'-8" 1'-5" 5' 620 45 9 QSOOSg§ 371/2" Hemi. 10' 4'-2" 1'-S" 5' 950 1 37 ) 30 1 8 6 1000 wg. 41" Hemi. 16' 4'-511 V-8" 113�1" 1,800 17 115 6 1 5 1450 wg. 1 461/2" Ellip. 17'-4" 4'-11" V-9" 117' 2,650 12 4 1590 wg. 461/2" Ellip. 23'-11" 41-11" 11-911 16' 3,520 8 4 Dimensions and specifications shown are approximate. Individual vessels may vary. -Leg spacing+/-2". Leg widths and spacing may vary based on mfg.location. Check with your salesperson for details. 120,250, 320 wg. standard tanks -no holes in legs (one center hole on request). 500 and 1000 wg. standard tanks-2 holes 16" on ceraer. 1450 wg. and up as shown above. •• Full load and stack quantities vary by shipping location. Check with your salesperson for details. General Specifications - Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels, Section Vill, Division 1. Complies with NFPA 58. Rated at 250 psig from -20" F to 125' F. All vessels registered with National Board. Two service. options available: Option 1: Ready -to -bury underground option, coated with either powder coated phenolic epoxy finish or liquid applied epoxy primer coat followed by urethane top coat, supplied with composite AG/UG dome. Option 2: Aboveground option, coated with either powder coated TGIC polyester finish or liquid applied epoxy primer coat followed by urethane topcoat, supplied with steel AG/UG dome. - All vessels are shipped vacuum pre -purged to enable simplified first fill of the vessel. Updated June 30, 2015