HomeMy WebLinkAboutSUBMITTED PAPERWORKREQUEST FOR 30 DAY TEMPORARY POWER RELEASE
DATE:
11 • z-1- • qi
St. Lucie County Comm. Devel. Dept.
Code Compliance Division
2300 Virginia Avenue
Fort Pierce, FL 34982-5652
PERMIT NUMBER:
14 1-20631- — -- —
PROPERTY ADDRESS:
szo-r cil. Sc.saVI Jam, �
THE UNDERSIGNED HEREBY REQUEST RELEASE OF ELECTRICAL POWER TO
THE ABOVE DESCRIBED PROPERTY, FOR A PERIOD NOTTO EXCEED THIRTY (30)
DAYS, FOR THE PURPOSE OF TESTING SYSTEMS AND EQUIPMENT IN PREPARA-
TION FOR FINAL INSPECTION. IN CONSIDERATION OF APPROVAL OF THIS
REQUEST WE HEREBY ACKNOWLEDGE AND AGREE AS FOLLOWS:
1. This temporary power release is requested for the above stated purpose
only, and there will be no occupancy of any type, other than that permitted
by construction during this time period.
2. As witness by our signatures, we hereby agree to abide by all terms and
conditions of this agreement, includ':,g Building Division Policy, which is
incorporated herein by reference.
3. All conditions and requirements listed in the attached document entitled
"Requirements for 30 Day Power for Testing" have been fulfilled and the
premises is ready for compliance inspection.
We hereby release and agree to hold harmless, St. Lucie County, and their employees
from all liabilities and claims of any type or nature which may arise now or in the future
out of this transaction, including any damages which may be incurred due to the
disconnection of electrical power in the event of violation of this agreement.
Tol{WS0
_b5/24/2000 10:24
r.
5613374048
ACTION AIR & HEAT
PAGE 02
,,ACTION
AIR CONDITIONING & HEATING, INC.
1688 SE VILLAGE GREEN DRIVE
PORT ST. LUCIE, FL 34952
FAX 337-6242 F ILE ®PT
FAX 337-4048
STATE LIC. # CAC033649
COVI Si.
5304 ECHO FINES CIRCLE
05/24/2000
whom, it may concern,
The ductwork in the master bath, which is a 10x6-6 in the bath area and an 8x4-4
the toilet area, is the proper size to meet the CFM requirements for that area The
cts are also installed in the correct locations in order to provide air to both areas
Should you have any questions, please contact me.
THESE PLANS AND ALL PROPOSED WORK,
ARE SUEJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
Sincerely,
&4 Q�
Buddy Britton
!
JOB Op
. BE MADE
-65/24/2000 10:24 5613374048 ACTION AIR & HEAT PAGE 01
Ll
ACTION AM CONDITIONING & HEATING, INC.
1688 SE VILLAGE GREEN DRIVE
.PORT ST. LUCIE, FL 34952
(561)337-6242
FAX: 337-4048
STATE LICENSE # CAC033649
FAX COMER SHEET
ST. LUCIE CO. BLDG. DEPT
JOB
BUDDY BRITTON
DAtX; 05/24/2000
5304 ECHO PINES CIIL
PERMIT #99120631
PECK CONSTRUCTIOD
# Of PAGES INCLUDING COVER: 2
SHOULD YOU HAVE ANY QUESTIONS, PLEASE CALL.
P.O. BOX 12059
LAKE PARK, FL 33403
IN PLACE SOIL DENSITY
(NUCLEAR METHOD) ASTM D
Date: ' MARCH 3, 2000 - — -
Job #: P00-0558
Permit #: 99-12il631
Client: PECK CONSTRUCTION
Contractor: PECK CONSTRUCTION
Job Location: 5207 SUSON LANE
ST.LUCIE COUNTY, FLORIDA
Test Test Sample Depth In Place
No. Location Dry Density
Density - Foundation Fill
Below Slab
Grade
1 NW Comer 0-1' 108.2
2 Center 0-1' 109.3
3 SE Corner 0-1' 110.0
INC.
PHONE: (561) 845-7445 WEST PALM BEACH (561) 337-7755 MARTIN-ST. LUCIE
(561) 564-0940 INDIAN RIVER(561) 845-8876 FAX
In 9200
2000
mue��, �etos�
ST. V_E!C[0 LOuesTa; EL ,�
Maximum
Dry Density
113.1
% Com-
pacted
95.7%
96.6%
97.2%
.�
f
e -rF 1 . GMPFRING & TESTING INC..
P.O. BOX 12059
LAKE PARK, FL 33403
SOIL DENSITY REPORT
MOISTURE DENSITY RELATIONSHIP
-T=180 -- -
Sample Optimum Max. Dry Soil Test
Location Moisture Density Description No.
A
Composite 11.6 113.1 Brown
Slightly Clayey
Fine Sand
+----------- ---------- ---------- ---------- --------+
114
+---------+---------+---------+---------+---------+
113
+---------+---------+--
-+---------+---------+
112
+-----
-+---------+---------+---------+
--------+
+
+
+
+ +
+-
111
+---------+---------+---------+---------+------
-+
+---------+---------+---------+---------+---------+
10
11
12 13
Moisture % Dry Weight
10
PHONE: (561) 845-7445 WEST PALM BEACH (561) 337-7755 MARTIN-ST. LUCIE
(561) 564-0940 INDIAN RIVER(561) 845-8876 FAX
ST. LUCIE COUNTY
DEPARTMENT OF COMMUNITY DEVELOPMENT
2300 VIRGINIA AVENUE
FT. PIERCE, FL. 34982-5652
561-462-1553
DESIGN CERTIFICATION FOR WIND LOAD COMPLIANCE
This Certification is to be completed by the project design architect or engineer. This Certification must be subrhijted with all appIlEations
for building permit involving the construction of new residence (single ormulti-family), residential addition, any accessory structure requiring
a building permit, and any nonresidential structure. This Certification shall not apply to interior renovations (provided that no structural
walls, columns or other similar component is being effected) and certain other minor building permits. For further assistance, please
contact the Building Inspection Office at 462-1553 or 462-2172.
PROJECT NAME
.1 O kvi SOvn Re S I Cl Bvl�s-.
-OFFICE USE ONLY
STREET ADDRESS
S ;LO? W • stL sovl
PR NUMBER
'Et. D nAa FL.
PERMIT NUMBER
OCCP. TYPE
... ,
CST.TYPE
CERTIFICATION STATEMENT:
fw t,
031
I CERTIFY THAT, TO THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS HAVE
BEEN DESIGNED TO COMPLY WITH THE APPLICABLE STRUCTURAL PORTION OF THE BUILDINGACODES
CURRENTLY ADOPTED AND ENFORCED BY ST. LUCIE COUNTY. I ALSO CERTIFY THAT STRUCTURAL ELEMENTS
DEPICTED ON THESE PLANS PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS AND FORCES SPECIFIED
BY CURRENT CODE PROVISIONS.
DESIGN PARAMETERS AND ASSUMPTIONS USED• (please check or omplete the approorite box)
1. BUILDING CODE EDITION USED (YEAR) 97 SBCCI ASCE 7-86 OTHER (SPECIFY) 44
2. BUILDING DESIGN IS (CHECK ONE) ENCLOSED ✓ PARTIALLY ENCLOSED OPEN BUILDING
3. BUILDING HEIGHT: G / 5 FT 4. WIND SPEED USED IN BUILDING DESIGN: 1/0 MPH
5. WIND EXPOSURE CLASSIFICATION (REFER TO EXPOSURE TABLES IN BUILDING CODE IDENTIFIED IN LINE Yt): c ✓f) S L
6. AVERAGE WIND VELOCITY PRESSURE ON EXTERIOR FACES OF STRUCTURE: • Zk. 7 PSF
7. PEAK WIND VELOCITY PRESSURE ON EXTERIOR FACES OF STRUCTURE: PSF
6. IMPORTANCE/USE FACTOR (OBTAIN FROM BUILDING CODE)). �-
S. LOADS: FLOOR PSF ROOF/DEAD: 1 -7 PSF ROOF/LIVE: 3 U PSF
10. WERE SHEAR WALLS CONSIDERED FOR STRUCTURE (CHECK ONE) YES NO— If NO, why? (attach
explaination)
11. IS A CONTINUOUS LOAD PATH PROVIDED (CHECK ONE) YES �� NO
explaination)
12. ARE COMPONENT AND CLADDING DETAILS PROVIDED (CHECK ONE) YES _
explaination)
13. MINIMUM SOIL BEARING PRESSURE: Z SU J PSF
If NO, why? (attach
NO— If NO, why? (attach
AS WITNESSED BY MY SEAL, I HEREBY CERTIFY THAT THE INFORMATION INCLUDED
IS TRUE AND CORRECT, TO THE BEST OF MY KNOWLEDGE AND BELIEF.
NAME: 1yo-t-n5y/C
DESIGN FIRM: L'
CERTIFICATION NO: y 6- 6 3 5
DATE:
StCERTIM ,I
NQ. 46635 i
i o I ATH
� I G`2Lo R iV4w
X9�'LGFpp xpxom
SERIAL S 5268
• RESMANUJ(c) •
WHOLE HOUSE
HEAT GAIN / HEAT LOSS CALCULATION USING EPI92-FLA/RES(c) DATA FILES
(BASED ON A.C.C.A. KAWAL J-- SEVENTH EDITION (c)--198( by A.C.C.A.)
Conditioned Floor Area : 2008 SF
• Cl imatTc Condi t iorre- & Des-ign Conditions •
------------------ ------------
Geograplricwl Location- r -Florrda___ -,: _ Fort .Pierce
North Lat-itude / - E-levatirnr-
Outdoor Winter Dry Bulb
Indoor Winter Dry Bulb ---
Winter (Actual) Temp.Diff.
Winter 'Temp. Dlff. (wT-dY
Outdoor Summer Dry Bulb
Outdoor Summer Wet Bulb- -
Outdoor Summer Humidity Ratio
Indoor Summer Relaltive-Huz�idity
Indoor Summer Design Grains / Lb.
Indoor Summer Dry -Bulb
Indoor Summer Wet Bulb
Summer Daily Range
Summer (Actual) Temp.Diff.
Summer (User Sel) Temp.Diff. (STA)
: 2i Deg. /
: 42 Deg. F
: 70 Deg. F
: 28 Deg. F
: 40 Deg. F
: 90 Deg. F
: 78 Deg. F
: 127
: 50X
62
: 75 Deg. F
: 62.3 Deg.
r51 Deg. F
: 15 Deg. F
: 20 Deg. F
10-- Ft-. -Above Sea Level
F ! 64 Gr/Lb
- L
------� HEATI1NG--SMMAR1F •-- •-- COOLI-NG_SURY •
------------------------------ -----------
SUBTOTAL 15170-_19_.:STRUCTURE._SENSIBLE.. 23731.94
:MECH.VENT- 0 Cfm 0.00
,.SENS. + MECH.VENT 23731.94
;TEMP.SWING e 3 DEG..: 1.00
:OCCUPANT/APPLIANCE 3000.00
DUCT LOSS 2909.62 :DUCT GAIN 3083.15
TOTAL LOSS/BTUH 39279.81 :TOTAL SENSIBLE 29817.09
;'TOTAL LATENT 4773.06
------------------------------------------------------ n
OVERSIZE FACTOR 7855.96 :20E SENS.OVRSZE FTR: 5963.42
ACTUAL + 20% OVERSIZE: 47135.77 !SENS. + 20% OVERSIZE: 35780.51
---------- - ---------------------
------------�-EQUIPMENT SELECTION • �----------- -
--------------------------------------------------------------------
EQT. MANUF.ReiiiA MODEL 0 u.RKA e4a TYPE ST, Oaef
HTG INPUT 1A IGJ G OUTPUT%#lye UE/HSPF
SENSIBLE CLG 31t9d0 LATENT CLG I 'ad TOTAL 4,2. AAQ_?ONAOE-3-.$
(S)EER 10.3 CLG CFM ►ode HTG C
Or �
,o
L • L 0 A D C"A L C U ,l A T I O
N s
_ TYPE Inside Shade Sc Area
Lose/Stuh
Gain/Btuh
L'A S 5------------------------ -----------------------------------------
aat Single CIr Drapes/Blinds 1 67.90
3136.98
3530.80
Drih Single Clr Drapes/Blinds 1 124..90.
a26.98
322.20
eat Single Cir Drapes/Blinds 1 189.30
8745.66••
9843.60
Duth Single Clr Dragen/Elinds 1 21.20
979.44
593.60
nfiltration : Winter Htm ( 14.82 ) x 296.30
4391.17,
nfiltration : Summer Htm ( 3.67 ) x 296.30
1067.42
---------
---------
indow Frame : Metal SUBTOTALS: 296.30
---------
18080.23
15377.62
R-Value Area
Loss/Btuh-
Gain/Btuh
AL L S--_----------------------------------------------- - ------------__
/W C.B. - int insul__
2
- Ext. S.1363-.O0
3276.00,
2194.00
ood Stud - Adj. 11 232.00
535.20'
394.40
---------
---------
SUBTOTALS: 1597.00
---------
4111.20
2578.40
OO R 5---------------------------------------------------------------------
nsulated Core/Metal - Ext. 0 36.00
637.20
187.20
nsulated Core/Metal - Ext. 0 13.00
230.10,.
67.60
olid Care/wood - Adj. 0 17.00
377.40'
71.40
nfiltration :Winter Htm( I*.82 r x- 66-:OG--
978.12
nfiltration :Summer Htm( 3.67 ) x 66.00
242.22
---------
---------
SUBTOTALS: 66.00
---------
2222.82
568.42
EI L I N O 3 ----------------------------------------------------------------
ndcr Attic 19 2083.00
4374.30
5207.50
LO O R S --------------------------------------------------------------------
lab on Grade D 234.00 Lin.Ft.
7581.60
000.00
• TOTAL STRUCTURE -SENSIBLE ;
363-70 - 19_. 23731. 94
FORM 60OA-97
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: JOHNSON
Builder: PECK CONST.
Address:
City, State:
Permitting Office:
Owner: JOHNSON RES.
Permit Number:
Climate Zone: Central
Jurisdiction Number:
New construction or existing
New _
12, Cooling systems
Single family or multi -family
Number of units, if multi -family
Single family _
a. Central Unit
Cap: 48.0 kBtu/hr _
Number of Bedrooms
[7.
1 —
3
b. N/A
SEER 10.00 _
Is this a worst case?
_
No
Conditioned floor area (W)
_
2008 R2
c. N/A
Glass area & type
—
a. Clear - single pane
296.3 ft2 _
13. Healing systems
b. Clear - double pane
C. Tint/other SC/SHGC - single
0.0 112 _
a. Electric Strip
Ca 34.0 kBtu/hr
p
pane
d. Tintlother SC/SHGC - double lie
0.0 ft2 _
0.0 ft ,
b. N/A
COP: 1.00 _
8. Floor types
—
a. Slab -On -Grade Edge Insulation
R=0.0, 234.0(p) ft
c. N/A
b. N/A
—
—
c. Wall
9. types
14. Hot water systems
a. Concrete, Ira Insul, Exterior
—
R=8.2, 1365.0 ft2
a. Electric Resistance
Cap: 50.0 gallons
b. Frame, W
Wood, Adjacent
—
R=11.0, 232.0 ft2
b. N/A
EF: 0:93 _
c. N/A
—
—
e.. N/A
e. N/A
c. Conservation credits
HRU-AC
10. Ceiling types
(HR-Heat recovery, Solar
a. Under Attic
_
R=19.Q, 2083.0 ft2
DHP-Dedicated beat pump)
15. HVAC credits
b. N/A
_
_
(CF-Ceiling fan, CV -Cross ventilation,
11. Ducts c.
Ducts
HF-Whole house fan,
a. Sup: Unc. Ret: Con. AH: Interior
_
Sup. R�.O, 75.0 ft _
PT -Programmable Thermostat,
RB-Attic radiant barrier,
b. N/A
MZ-C-Muitizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.15
tal as -built points: 26613.00
ToTotal PASS
base points:
28048.00
I hereby certify that the plans and specifications covered
by this calculation are in compliance with the Florida
Energy Code.
PREPARED BY:
DATE: I2/inA
I hereby certify that this buil ing, as designed, is in
compliance with the Florid ne gy C d�j
OWNER/AGENT: I- 8 G
DATE: /z -3o-,f
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL: _
DATE:
EnerovGaUnetitti (Version: FLRCNA-200)
FORM 60OA-97
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS:...
PERMIT #:
BASE
AS -BUILT
GLASS TYPES
18 X Conditioned X
BSPM =
Points
Overhang
Floor Area
Type/SC
Omt
Len
Hgt Area
X SPM
X SOF
= Points
.18 2008.0
42.08
15208.5
Single, Clear
E
2.0
5.0 15.0
59.31
0.81
716.8
Single, Clear
E
2.0
6.0 42.9
59.31
0.85
2174.9
Single, Clear
E
9.0
0.5 10.0
59.31
0.36
215.3
Single, Clear
N
2.0
4.5 13.0
27.96
0.86
311.7
Single, Clear
N
2.0
1.5 4.9
27.96
0.68
93.6
Single, Clear
W
2.0
4.5 13.0
53.47
0.77
538.4
Single, Clear
W
2.0
6.5 36.0
53.47
0.87
1680.9
Single, Clear
W
10.0
7.5 60.0
53A7
0.48
1552.3
Single, Clear
W
12.0
5.0 18.3
53.47
0.41
398.3
Single, Clear
W
12.0
7.5 33.0
53.47
0.45
799.6
Single, Clear
W
10.0
7.5 29.0
53.47
0.48
750.3
Single, Clear
S
2.0
1.5 9.6
44.66
0.53
227.1
Single, Clear
S
2.0
5.5 11.6
44.66
0.77
400.9
As -Built Total:
296.3
9860.1
WALL TYPES
Area X
BSPM =
Points
Type
R-Value
Area X
SPM =
Points
Adajcent
232.0
0.7
162.4
Concrete, Int Insul, Exterior
82
1365.0
0.68
928.2
Exterior
1365.0
1.90
2593.5
Frame, Wood, Adjacent
11.0
232.0
0.70
162.4
Base Total:
1597.0
2755.9
As -Bunk Total:
1697.0
1090.6
DOOR TYPES
Area X
BSPM =
Points
Type
Area X
SPM =
Points
Adjacent
17.0
1.60
27.2
Exterior Insulated
36.0
4.80
172.8
Exterior
49.0
4.80
235.2
Exterior Insulated
13.0
4.80
62.4
Adjacent Wood
17.0
2.40
40.8
Base Total:
66.0
262.4
As -Built Total:
66.0
276.0
CEILING TYPES
Area X
BSPM =
Paints
Type
R-Value
Area X
SP7 =
Points
Under Attic
2008.0
0.60
1204.8
Under Attic
19.0
2083.0
1.10
2291.3
Base Total:
2008.0
1204.8
As -Built Total:
2083.0
2291.3
FLOOR TYPES
Area X
BSPM =
Points
Type
R-Value
Area X
SPM =
Points
Slab
234.0(p)
-31.8
-7441.2
Slab -On -Grade Edge Insulation
0.0
234.0(p)
31.90
-7464.6
Raised
0.0
0.00
0.0
Base Total:
-74412
As -Built Total:
-7464.E
EnrrouGaunr.0 DCA Fnrrn 60OA-97 EnPmvGaunPd01FIaRES'97 FLRCNA-200
FORM 60OA-97
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS:...
PERMIT #:
BASE
AS -BUILT
INFILTRATION
_ Area X_BSPM = Points-
- — --
-
Area X SPM
= Points
2008.0 14.31
28734.5
2008.0
14.31
28734.6
Summer Base Points:
40724.9
Summer As -Built Points:
34787.9
Total Summer
Points
X System =
Multiplier
Cooling
Points
Total X
Cap
X Duct X
System X
Credit
= Cooling
Component
Ratio
Multiplier
Multiplier
Multiplier
Points
40724.9
0.3577
14567.3
34787.9
1.00
0.971
0.341
1. 000
11517.7
EnaravGaunaw DCA Form 60OA-97 EnernvGaunPR/RaRES'97 FLRCNA-200
FORM 60OA-97
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS:...
PERMIT A
BASE
AS -BUILT
GLa_ss TYPES
_
.18 X Conditioned X
BWPM
= Points
Overhang
Floor Area
Type/SC
Ornt
Len
Hgt Area
X WPM X WOF
= Points
.18 2008.0
4.79
1731.1
Single, Clear
E
2.0
5.0 15.0
9.96
1.04
155.7
Single, Clear
E
2.0
6.0 42.9
9.96
1.03
440.4
Single, Clear
E
9.0
0.5 10.0
9.96
1.32
131.5
Single, Clear
N
2.0
4.5 13.0
12.32
0.99
159.3
Single, Clear
N
2.0
1.5 4.9
12.32
0.99
59.6
Single, Clear
W
2.0
4.5 13.0
10.74
1.04
144.7
Single, Clear
W
2.0
6.5 36.0
10.74
1.02
393.7
Single, Clear
W
10.0
7.5 60.0
10.74
1.10
707.7
Single, Clear
W
12.0
5.0 18.3
10.74
1.11
218.9
Single, Clear
W
12.0
7.5 33.0
10.74
1.10
391.5
Single, Clear
W
10.0
7.5 29.0
10.74
1.10
342.1
Single, Clear
s
2.0
1.5 9.6
7.73
2.05
151.8
Single, Clear
S
2.0
5.5 11.6
7.73
1.14
102.6
As -Built Total:
296.3
3399A
WALL TYPES Area X
BWPM
= Points
Type
R-Value
Area X
WPM =
Points
Adajcent 232.0
1.8
417.6
Concrete, Int Insul, Exterior
8.2
1365.0
2.06
2811.9
Exterior 1365.0
2.00
2730.0
Frame, Wood, Adjacent
11.0
232.0
1.80
417.6
Base Total: 1597.0
3147.6
As -Built Total:
1697.0
3229.E
DOOR TYPES Area X
BWPM
= Points
Type
Area X
WPM =
Points
Adjacent 1 17.0
4.00
68.0
Exterior Insulated
36.0
5.10
183.6
Exterior 49.0
5.10
249.9
Exterior Insulated
13.0
5.10
66.3
Adjacent Wood
17.0
5.90
100.3
Base Total: 66.0
317.9
As -Built Total:
66.0
350.2
CEILING TYPES Area X
BWPM =
Points
Type
R-Value
Area X
WPM =
Points
Under Attic 2008.0
0.60
1204.8
Under Attic
19.0
2083.0
1.00
2083.0
Base Total: 2008.0
1204.8
As -Built Total:
2083.0
2083.0
FLOOR TYPES Area X
BWPM =
Points
Type
R-Value
Area X
WPM =
Points
Slab 234.0(p)
-1.9
-444.6
Slab -On -Grade Edge Insulation
0.0
234.0(p)
2.50
585.0
Raised 0.0
0.00
0.0
Base Total:
.6
As-BuiR Total:
585.0
EnarnVGaunWA MCA Form 60OA-97 En .mvGaunaQ1FIaRES'97 FLRCNA-200
FORM 600A-97
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS:...
PERMIT #:
BASE
AS -BUILT
INFILTRATION
Area X BWPM = Points
Area X
WPM
= Points
2008.0
-0.28 -562.2
2008.0
-0.28
-562.2
Winter Base Points:
5394.6
Winter As -Built Points:
9084.8
Total Winter X
Points
System
Multiplier
= Heating
Points
Total X
Cap
X Duct X
System X
Credit
= Heating
Component
Ratio
Multiplier
Multiplier
Multiplier
Points
5394.6
1.0730
5788.4
9084.8
9084.8
1.000
1.00
0.989
0.989
1.000
1.000
1.000
1.000
8981.2
8981.2
EnerwGaunp- DCA Fnrm 60OA-97 EnP..rmiGauneW/RaREVQ7 FLRCNA-200
• FORM 60OA-97
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
ADDRESS:...
PERMIT A
BASE AS -BUILT
WATER HEATING
Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total
Bedrooms Volume Bedrooms Ratio Multiplier
3 2664.00 7692.0 50.0 0.93 3 1.00 2426.15 0.84 6113.9
As -Built Total: 6113.9
CODE
COMPLIANCE
STATUS
BASE
AS -BUILT
Cooling + Heating +
Points Points
Hot Water
Points
= Total
Points
Cooling
Points
+ Heating + Hot Water = Total
Points Points Points
14567.3 5788.4
7692.0
28047.7
11517.7
8981.2 6113.9 26612.8
PASS
EnermGaimP DCA Fnrm 60OA-97 EneravGaunr:WlFlaRES'97 FLRCNA-200
FORM 60OA-97
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS: , , ,
PERMIT #:
6A-21 INFILTRATION REDUCTION COMPLIANCE CHFCKI IST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
Exterior Windows .& Doors
606.1 ABC.1.1
Maximum:.3 cfm/s .ft, window area .5 cfmis door area.
CHECK
Exterior & Adjacent Walls
606.1.ABC.12.1
.ft,
Caulk, gasket, weatherstrip. or. sea[ between: windows/doors & frames, surrounding wall;
foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility
penetrations; between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infittration barrier is installed that extends
from and is sealed to the foundation to the to late.
Floors
606.1.ABC.1.2.2
Penetrations/openings>1/8" sealed unless backed by truss orjoint members.
EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
to the perimeter, penetrations and seams.
Ceilings
606.1 ABC.1.2.3
Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
Recessed Ughting Fbrtures
606.1 ABCA 2.4
installed that is sealed at the perimeter, at penetrations and seams.
Type IC rated with no penetrations, sealed; or Type IC or non installed
-IC rated, inside a
sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
conditioned space, tested.
Multi -story Houses
606.1ABC.12.5
Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts
606.1 ABC.1.3
Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
have combustion air.
6A-22 OTHER PRFRC92IPTI1rP eeonennec ._.._..
COMPONENTS
SECTION
un ure[ or exceeaea Dv an residences.
REQUIREMENTS
CHECK
Water Heaters
Swimming Pools & Spas
612.1
612.1
Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit
breaker (eleqtrkcj or cutoff as must be provAided. E demal or builtin heat tra re uired.
Spas & heated pools must have covers (except solar heated). Non-commercial pools
must have a pump timer. Gas spa & pool heaters must have a minimum thermal
efficient of 78%.
Shower heads
Air Distribution Systems
HVAC Controls
Insulation
612.1
610.1
607.1
604.1, 602.1
Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min. insulation.
Separate readilyaccessible manual or automatic thermostat for each s em.
Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides.
Common ceiling & floors R-11.
EneravGahme- DCA Form 60OA-97 EnernvGauaeQ/RaRES'97 FLRCNA-200
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE* = 82.5
The higher the score, the more efficient the home.
JOHNSON RES., , , ,
1. New construction or existing
New _
12. Cooling systems
2. Single family or multi -family
3. Number of units, if multi -family
Single family _
a. Central Unit
Cap: 48.0 kB[u/hr _
4. Number of Bedrooms
1
- 3
SEER: 10.00
5. Is this a worst case?
_
No
b. N/A
-
6. Conditioned floor area (ft2)
_
2008 112
c. N/A
7. Glass area & type
-
a. Clear -single pane
296.3 112 _
13. Heating systems
b. Clear - double pane
c. Tintlother SC/SHGC - single
0.0 ft2 _
a. Electric Strip
Cap: 34.0 kBtu/hr
p -
pane
d. Tint/other SC/SHGC - double pane
0.0 ft2 _
0.0 ft2
COP: 1.60 _
8. Floor types
b. N/A
-
a. Slab -On -Grade Edge Insulation
R=0.0, 234.0(p) It
c. N/A
b. N/A
-
_
a N/A
9. Wail types
14. Hot water systems
a. Concrete, Int Insul, Exterior
-
R=8.2, 1365.0 ft2
a. Electric Resistance
Cap: 50.0 gallons _
b. Frame, Wood, Adjacent
R=11.0, 232.0 W
b. N/A
EF: 0.93
c. N/A
-
_
e.. N/A
e. N/A
-
c. Conservation credits
HRU-AC
10. Ceiling types
(HR-Heat recovery, Solar
_
a. Under Attic
_
DHP-Dedicated heat pump)
R=19.0, 2083.0 ft2
15. HVAC credits
b. N/A
_
_
fan, CV -Cross ventilation,
c.
HF-Whole hoe fan,
home
11. Ducts
Ducts
_
PT -Programmable Thermostat,
a. Sup: Une. Ret: Con. AH: Interior
Sup. R�.q 75.0 ItRB-Attic
_
radiant barrier,
b. N/A
W-C-Multiwne cooling,
W-H-Multizone healing)
I certify that this home has complied with the Florida Energy Efficiency Code For Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
'NOTE: The home's estimated energyperformance score is only available through the FLARES computer program.
This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPAIDOE EnergyStartr'desig:atiorr),
your home may qualify for energy efficiency mortgage (F,F,h4) incentives if you obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 4071638-1492 or see the Energy Gauge web site at www.fsec. ucf edii for
information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction,
contact the Department of Community Affairs at 8501487-1824.
F.nerevCTangp.Q Wersioo- FLIZMA-2001
WATER 3
HOLIDAY PINES SUB PHASE I LOT 158 METER I
PLAT BOOK 18, PAGE 16 (OCCUPIED) FIND. CM
Ln �mz 1311,FINCM N 90000'00" W 50.54' (MEAS.) FFE=11.89 FI DIA. 1 � I
CO NJ Z 00 N 4 DIA.
H ¢ ml� S IRRkakf �� ELL �p I15U ' a 29.90
0 00 � � » ,coca 38 00
J
t
• - Prz�� w BOX
ui
�cf)
I�ZOFOED 2c�8 20-I -
w + .5 3� 2/2 I�il�a= DIzI�G N w �
� v I�
Q_ ICo• I 00�
Ln z p
� 1
cn
4 O I
In
N
Ln _ I U7
CN
O
O
POLE AD��1
ANCHOR� �gDO01Cb
,�
—R W AND. 2" IP ET IR&C Ob'I/���
OHW OHW OHW
° N 90000 00 E 125.00 (MEAS.)--- �IWOOD r-
1 6,6�/
o (.0 16' ORARY DRAINAGE EASEMENT POLE [)
O
— — ;Fcb'
FND. N&TT
FLOOD ZONE: °X'
FRONT_ EDGE OF PAVEMENT
SIDES__ S
CNR SIDES �-- -
/5' SUS01V LANE
REAR
!7s::::(20' ASPHALT PAVEMEP
SURVEYOR'S CERTIFICAT TECH.
I HEREBY CERTIFY THAT THIS SURVE �"^6RiPStON
AND IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE AND BELIEF
AS SURVEYED IN THE FIELD. I FURTHER CERTIFY THAT THIS SURVEY
COMPLIES WITH THE MINIMUM TECHNICAL STANDARDS SET FORTH IN
CHAPTER 61G-17-6 BY HE FLORIDA BOARD OF LAND SURVEYORS
PURSUANT TO SECTIO 27 RID9STATUTES, AND THAT THERE
ARE NO ABOVND EACf{MENT�QTHER THAN SHOWN.
R R AND MAPPER
iTION #4572
P.S.M.
LEGEND:
IN —FOUND CONCRETE MONUMENT
• —FOUND IRON ROD
O -SET IRON ROD AND CAP
NUMBER 4572
-CENTER UNE
FFE -FINISH FLOOR ELEVATION
PSM -PROFESSIONAL SURVEYOR
AND MAPPER
R/W -RIGHT-OF-WAY
PC -POINT OF CURVE
D -DELTA ANGLE
A -ARC LENGTH
-TYPICAL ELEVATION
RIGHT -OF -WA
Is I
'K&D
AED 10.00
EDGE OF PAVEMENT
FRED W. REPASS
LAND SURVEYING & MAPPING
706 BUCK — HENDRY WAY
P.O. BOX 3424
STUART, FL 34995
PH. (561) 692-3827 FAX: (561) 692-9529
LEGAL DESCRIPTION:
ALL OF LOT 366, HOLIDAY PINES, PHASE IIB
ACCORDING TO THE PLAT THEREOF, AS
RECORDED IN PLAT BOOK 20 PAGE 12-0
OF THE PUBLIC RECORDS OF ST. LUCIE
COUNTY, FLORIDA.
STREET ADDRESS: SUSON LANE
SURVEY NOTES:
1.
NOT VAUD UNLESS SEALED WITH AN EMBOSSED
SURVEYOR'S SEAL
2.
LANDS SHOWN HEREON WERE NOT ABSTRACTED
FOR RIGHTS -OF -WAY, EASEMENTS OR OWNERSHIP.
3.
LAND DESCRIPTION HEREON WAS PROVIDED BY
THE CUENT.
4.
BEARINGS SHOWN HEREON ARE BASED ON THE
CENTERUNE OF SUSON LANE AS PLATTED.
I/) 5.
THIS SURVEY NOT TO BE USED FOR FENCE
�k
INSTALLATION, SPRINKLER SYSTEMS, SHRUBS OR
ANY OTHER UTIUTIES WITHOUT REVERIFICATION OF
PROPERTY CORNERS.
B.
ELEVATIONS SHOWN HERON ARE BASED UPON
ASSUMED DATUM.
CERTIFIED TO:
SHERON JOHNSON
HARBOR FEDERAL SAVINGS & LOAN
SCANNED
BY
St: b inia Pnil ',w •
SITE PLAN
PECK CONSTRUCTION
LE: DRAWN BY: FILE No.:
1" = 20' W.B.B. 99-756
0
HOLIDAY PINES SUB PHASE 1 WATER 3 LOCATION MAP
LOT 158 METER f y
PLAT BOOK 18, PAGE 16 o : HOLIDAYi11"'NES
Ln �1D. CM (OCCUPIED) FND. CMo °4" oiA. N 90000'00" W 50.54' (MEAS.) FFE=11.89 4" oiA- ^ lb °, ^o. 3 PRoPc�ir>v_ C~FND. PK&D4-5 IRRVskfla� `A `ELL >0 1 r2o I T29.90M°
�r' ASS MED 10.00 s x�
i- Q aZ 14rw•.�0, �9 • p 0 3r 30.00 6 qai . c, �t-INDIAN PINES
v�c'i r Ca.� I cc in I BELL I, {a %-OOLFICOURSE
%7i0.2 rc BOX F- I aWI z i TpROVOi p WLN 1-4 :2 Q ./TONfA��C
N Lr-/L Ln-� J %
Q t"" ' fr. ! '/ �•I N �, Q I D- O ' PNWV 1 . '' a
�1 , :� I z $ v •a `EAGLE'ORLL L 0) 00'
- 11 o.am5.o Q _ Q 2 ��'��19�f0 PINES Clfl RAILEVR 0R p'9�ocF -- —
U I�•�'; a ( �_;LJL MIaAMAx PINES DR Qrr) oo O I CD
i!�-IQ0
Ly — LEGAL DESCRIPTION:
0
a
ALL OF LOT 366, HOLIDAY PINES, PHASE IIB
Of I C,a �• I ACCORDING TO THE PLAT THEREOF, AS
I 1 �o I ^OJ RECORDED IN PLAT BOOK 20 PAGE 12-D
N
K.3 W .�O' -� �•J OF THE PUBLIC RECORDS OF ST. LUCIE
_ COUNTY, FLORIDA.
N -~� - 3� I� s.o + i STREET ADDRESS:$2?I SUSON LANE
p 'N ! SURVEY NOTES:
(n POLE A5 ( 1. NOT VALID UNLESS SEALED WITH AN EMBOSSED
ANCHOR ��O ) ' 2• LANDS SURVEYSHOWN SEAL.
HEREON WERE NOT ABSTRACTED
cJ �J 0.O , FOR RIGHTS -OF -WAY, EASEMENTS OR OWNERSHIP.
_ _R W °FND. 2" �P ET IR&C _g �O O / I , 3. LAND DESCRIPTION HEREON WAS PROVIDED DY
OHW OHW OHW �� \ THE CLIENT.
____ e a e _ ___ __ __ _ __ __ _ __ _ �_- -- _ _ _
4. BEARINGS SHOWN HEREON ARE BASED ON THE
N 90"00 00 E 125.00 MEAS. I -- % — IS SURVEY
E OF SUSON LANE AS PLATTED.
6; — CE
^. � ( 1�WOOD ___ I� � � ��N 5. THIS SURVEY NOT TO BE USED FOR FENCE
1 - SWALE+ POWER _� 6, 6�� ) �k INSTALLATION, SPRINKLER SYSTEMS, SHRUBS -OR
POLE ��) ANY OTHER UTILITIES WITHOUT REVERIFICATION OF
'o (D 16 TEMPORARY DRAINAGE EASEMENT j PROPERTY CORNERS.
C7 CD q, (O.R.B. 290 PAGE 445) —� fi. ELEVATIONS SHOWN HERON ARE BASED UPON
• � � _ _ ASSUMED DATUM.Lc) Lcj
EDGE OF PAVEMENT CERTIFIED TO:
_ _ _ _ _ �• _ SHERON JOHNSON
FFND. N&TT S OSU N LANE HARBOR FEDERAL SAVINGS & LOAN n
FLOOD ZONE:"X' S�^1lN�
--PANE#:-12Ttt0007a-�— _ __ (20' ASPHALT PAVEMENT) BY
(70' RIGHT-OF-WAY) EDGE OF PAVEMENT Sf.I ilcipr.nLm1h,
SURVEYOR'S CERTIFICATE LEGEND: — -- _— -
I HEREBY CERTIFY THAT THIS SURVEY MAP IS PER RECORD DESCRIPTION ■ -FOUND CONCRETE MONUMENT Pool �116C
AND IS TRUE AND CORRECT TO TH T KNOWLEDGE AND BELIEF • -FOUND IRON ROD FIELD WORK COMPLETED: i1-21-99
AS SURVEYED IN THE FIELD.I ERTI THAT THIS SURVEY 0-SETIRON ROD AND CAPNUMBER ---
COMPLIES WITH THE MINI T CAL S DARDS SET FORTH IN q -CENTER LINE 2 FR E D W. REPASS FORM BOARD TIE-IN
CHAPTER 61G-17-6 TH ORIDA RD OF LAND SURVEYORS FFE -FINISH FLOOR ELEVATION
ARESNONABOO S RO_N EN.027 CRO �MENTS OTHER THAN S OWN A STATUTES, AND THAT THERE PSM-PROFESSIONAL
SURVEYOR LAND SURVEYING & MAPPING PREPARED ON THE ORDER OF:
R/W -RIGHT-OF-WAY
rn G706 BUCK - HENDRY WAY PECK CONSTRUCTION
—_DATE: _� `+ � PC -POINT OF CURVE
— D -DELTA ANGLE P.O. BOX 3424
PROFESSIONAL SU YOR AND MAPPER A -ARC LENGTH STUART, FL 34995 SCALE: DRAWN BY: FILE No.:
FLORIDA REGIS ON #4572-TYPICAL ELEVATION PH. (561) 692-3827 FAX: (561) 692-9529 1" = 20 W.B.B. 99-756
FIRE W. REP S P.S.M.
���•v� � .
E!
CN
O
0
m
_R
HOLIDAY PINES SUB PHASE I LOT 158
PLAT BOOK 18, PAGE 16
�N 4 DIAM N 90'00'00" W-A50.54' (MEAS.) (OCCUPIED) O n
91,
2_IP
•
.•
Im 22.1j'
LN
70 P (5;1-- I=matiil_�p m
I�"5 ��' II•C�
— D
I�o•-I'
WATER
METER
FND. CM
O
4" DIA.
29.90
.1
30.00,
BELL
F[:U2 'G' ;ap W BOX
20'
cn
12171 \1-r N-d a
U
0_
Ld O �O
I ^ +
In
POLE AD,\��
ANCHOR ��OOV '\:
IR&C
V, I rr - Uri YY UP11'V - +•'
- N 90000'00" E 125.00' (MEAS.)-----
---SWALE+ _ POWEf7__-9:� 66(
0 0+ 16' TEMPORARY DRAINAGE EASEMENT ROLE
Sri ri (O.R.B. 290 PAGE 445)
EDGE OF PAVEMENT
hFND. N&TT SUSON LANE
FLOOD ZONE:"X' (20' ASPHALT PAVEMENT)
--P NEt�:--l2rrreao�ef— -
(70' RIGHT-OF-WAY)_
SURVEYOR'S CERTIFICATE LEGEND:
I HEREBY CERTIFY THAT THIS SURVEY MAP IS PER RECORD DESCRIPTION ■ —FOUND CONCRETE MONUMENT
AND IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE AND BELIEF • —FOUND IRON ROD
AS SURVEYED IN THE FIELD. I FURTHER CERTIFY THAT THIS SURVEY 0 —SET IRON ROD AND CAP
COMPLIES WITH THE MINIMU L STANDARDS SET FORTH IN NUMBER 4572
CHAPTER 61G-17-6 B RID BOARD OF LAND SURVEYORS F —CENTER LINE
FFE —FINISH FLOOR ELEVATION
PURSUANT TO S 2.027�F ORIDA STATUTES, AND THAT THERE PSM —PROFESSIONAL SURVEYOR
ARE NO AB G D EN 4ACHMENTS OTHER THAN SHOWN. AND MAPPER
' IV[J " l R —RIGHT—OF—WAY
B_ _l Y: _ DATE: PC
—POINT OF CURVE
D —DELTA ANGLE
PROFESSIOI URVEYOR AND MAPPER A —ARC LENGTH
FLORIDA ISTRATON //4572—TYPICAL ELEVATION
FRED W PASS P.S.M.
rob I o0
o•� moo'
` FND.
MJ ASS
w Iw r
VI
-- Q>3
V 0
I
J
¢ 2
WIC
I¢o
O
N
,
0
PK&D
VIED 10.00
0
LEGAL DESCRIPTION:
ALL OF LOT 366, HOLIDAY PINES, PHASE IIB
ACCORDING TO THE PLAT THEREOF, AS
RECORDED IN PLAT BOOK 20 PAGE 12-D
OF THE PUBLIC RECORDS OF ST. LUCIE
COUNTY, FLORIDA.
STREET ADDRESS: 61cdj SUSON LANE
—_
SURVEY NOTES:
1.
NOT VALID UNLESS SEALED WITH AN EMBOSSED
SURVEYOR'S SEAL
2.
LANDS SHOWN HEREON WERE NOT ABSTRACTED
FOR RIGHTS -OF -WAY, EASEMENTS OR OWNERSHIP.
3.
LAND DESCRIPTION HEREON WAS PROVIDED BY
THE CLIENT.
4
BEARINGS HOFmSHEREON RBASED THE
6: � --
CENTERLINE SUSON LANEASPLATTED.
1 /Vk) 5.
\ �k
THIS SURVEY NOT TO BE USED FOR FENCE
INSTALLATION, SPRINKLER SYSTEMS, SHRUBS -OR
\
ANY OTHER UTILITIES WITHOUT REVERIFICATION OF
PROPERTY CORNERS.
6.
ELEVATIONS SHOWN HERON ARE BASED UPON
ASSUMED DATUM.
"D. 1z 1(%n I vIUI`� I IT
FRED W. REPASS
LAND SURVEYING & MAPPING
706 BUCK - HENDRY WAY
P.O. BOX 3424
STUART, FL 34995
PH. (561) 692-3827 FAX: (561) 692-9529
CERTIFIED TO:
SHERON JOHNSON
HARBOR FEDERAL SAVINGS & LOAN
SCANNED
St. �IICIP�1111'ft�/
TIE-IN
PREPARED ON THE ORDER OF:
PECK CONSTRUCTION
SCALE: DRAWN BY: FILE No.:
1" = 20' W.B.B. 99-756