Loading...
HomeMy WebLinkAboutA.M. ENGINEERING PAPERWORK� . M. ENGINEERING AND TESAA� G, I RECEIVED 590 N.W. MERCANTILE PLACE PORT ST. LUCIE, FLORIDA 34986 LOCAL OFFICE: (772) 924-3575 FAX: (772) 924-3580 JUN 14 2007 Public Works . L. Lucie County FL REPORT OF FOUNDATION PAD COMPACTION Client: Lorraine Lewis 315 Southwest Salerno Road SCANNED Stuart, Florida 34997 BY Site: 594 Hidden River Drive st.-LIJ A 0111911sv Port St. Lucie, St. Lucie County, Florida Foundation Pad Report Date: June 13,.2007 Project No: 11742 �w Lab No: Permit No: 0611-0030 Density tests and Hand Cone Penetrometer (HCP) readings were made at a minimum of three locations in the building pad. Density tests were performed in the upper one foot of fill. HCP readings were taken in hand auger boreholes at one foot intervals from slab grade through the depth of fill. The density tests were performed in general compliance with ASTM D 2922. The HCP test, in conjunction with information about the soil type, is empirically correlated to the relative. density of subsurface soils. Density Test No. Date Tested Location Elevation feet D Densi s Percent Compaction In Place Proctor 1 6/13/07 Northwest Comer 0-1 121.2 122.1 99.3 2 Center Area 0-1 120.2 122.1 98A 3 Southeast Comer 0-1 118.6 122.1 97.1 * All elevations are below bottom of slab. The depth of the fill was approximately 4 feet. The fill should extend at least five feet beyond the building perimeter. At the time of our testing no information was available regarding the foundation pad setbacks. In the locations and depths that were tested, the fill has been compacted to a minimum of 95 percent of the modified Proctor maximum dry density (ASTM D 1557). Distribution: Client - 3 Bldg. Dept. - 1 PCM/ah Submitted by: A. M. ENGqINEERING AND TESTING, INC. -De .1/13A 7 Paul C. Martin, P.F,. Florida Registration No. 65051 S:IFort'Pierce OJfzceWeL4pps1L=E LOG BOOKICommercial JobALewis, Lorraine1594 Hidden River Drive, PSLI17742 - Pad W. Fill.doc A. M. ENGINEERING AND TESTING, INC. 3504INDUSTRIAL 33PD STREET FT. PIERCE, FLORIDA 34946 LOCAL OFFICE: (772) 461-7508 FAx: (772J 461-8880 REPORT OF FOUNDATION PAD COMPACTION Client: Lorraine Lewis SCANNED Report Date: 1/27/06 By Project No: S� L OVAI,f inh, Report No: 8184 Site: 584 Hidden River Drive Permit No: St. Lucie County, Florida Foundation Pad Density tests and Hand Cone Penetrometer (HCP) readings were made at a minimum of three locations in the building pad. Density tests were performed in the upper one foot of fill. HCP readings were taken in hand auger boreholes at one foot intervals from slab grade through the depth of fill. The density tests were performed in general compliance with ASTM D 2922. The HCP test, in conjunction with information about the soil type, is empirically correlated to the relative density of subsurface soils. Density Test No. Date Tested Location Elevation (feet) Dry Density (pcf) Percent Compaction In Place Proctor 8184 1/24/06 SW Comer 0-1 118.8 122.1 97.3 Center 0-1 117.4 122.1 96.2 NE Comer 0-1 116.1 122.1 95.1 * All elevations are below slab grade. The depth of the fill was approximately 5%a feet. The fill should extend at least five feet beyond the building perimeter. At the time of our testing no information was available regarding the foundation pad setbacks. In the locations and depths that were tested, the fill has been compacted to a minimum of 95 percent of the modified Proctor maximum dry density (ASTM D 1557). No soil borings were performed below the recently placed fill. Distribution: Client — 2 Submitted by: A. M. ENGINEERING AND TESTING, INC. Rebecca Grant scoli, P.E� A. Florida Registration No. 51863 S.lForr Pierce 0fficeWet,4ppsV7TLE LOG BOOKWouse JobslMisc. House JobASaint Lucie Coun04Lmis(8184)584 Hidden River Dr..doc