Loading...
HomeMy WebLinkAboutBUILDING PLANS 101 -1108 14 1E1 L K 71 N Eno PLUMBING ROUGH IN / FINAL CONNECTION SCHEDULE RO" IN CONNECTION REMARKS RI. I TYPE SIZE HGT • DESCRIPTION SIZE HGT ITEM REMA S P-01 Direct Drain I-IR' 412" 4brd Blrk 1-IR" -IS- M13 verify w/ supplier P-02 Not and Cold Luster V2' 41, Hand Birk In' .30° 113 Verify w/ supplier P-03 Direct Drain I-W" 442" Nand Birk 1-IR" -101 M13 verify w/ supplier P-04 Hot and Ca1d Water 1/2' .120 Nand Birk 1/2' 430" MB Verify u✓ supplier P-05 Floor Sink 2" .on Thee Compartment Sink 1-1/2" .24" 4819 (3) ea Corrections P-06 Cold Ulster in. .124 A Ice Maker 1124 412" 111 1-ID F IG, filtered to A2' P-01 Floor Sink 2" On AlFreezer Coll 1• .12" 'M 3/4 Grate -Haft Taped B Cooler Coll 1' .12" 42708 P-08 Floor SING 2" On Two Compartment Sink I-IR" 424" 'Ml 2 as connections P-09 Hot and Cold Water in. .12. Two Compartment Sink 1/2' -40' 6021 P-10 Floor 51* 2" 40" A Ice Maker 3/8" 4524 VW BI Ice Maker 3/8" 452" Willi C Ice Bin 1' .b" 4007 P-II Hot and Cold Water - V7' .12" Thee Compartment Birk 1/2, 440• 0019 2 "on correctlons PA Flow Sink 2" 40" A DiO wsher 2" $' 40n Extra deep moor slrk B Dierimair r 2" .8" don C Booster Neater 3/4" Relief Valve d Dirty Dish Table IR" 4-24"23 013 Drain Trough E Dirty Dish Table 1.1/2" 013 Re Rinse Birk P-13 Cold Water. 0.412.Dish Machine 1/2' .74 4011 P-14 Hot and Cold water V7` .@" Re -Rinse 5pray 1/2• A, 9016 P-15 Hot and Cold Ulster in. .12. Silver soak Sink 1/2' .36" 405 P-16 Gas • In 47° fryer 1' 40' W58 Note 1 4 2 1w= btuhr P-11 Flow Birk 2' 1 .0" A Kettle Stand I' 46" 4046 Flexible Drain 51 Kettle Stand 1• .6" V46 Flexible Drain P-19 Not Ord Cold Water V2' .12. Kettle Stand tn' .40' 4846 Fill Faucet P-I9 Cold Water IA' .12. Steamer V2' 436" W43 P-20 Gae • 1-1/4" .12. Range 1-1/4' 433' 4042 Nola 4 4 2.60008 Muter P-21 � Hot Luster 3/4" 412° Booster Htr/Disheasher 3/4" 433" OV23 1140 F. Connect to OW P-22 Gas • In- .Q" Pressure Pyer In' 40" W41 Note M 4 2. BOOM buster P-23 Gae• V2' 412" Fryer 1/7' 49' V52 Note M 4 2. 920M bW,h P-24 Gas- IQ' .12" Pyer 1/2' A' V52 Note 4 4 2.172088 btuk P-25 Gas- 3/4" .R" Grooved Grill 3/4" 430' 4053 Note • 1 4 2 BOOM DIUM P-76 Flow SING 2" 40" Steamer 1-1/2" AV 4043 PJl Gas- 3/4" .12" Grill 3/4" d0' 4054 Note 4 4 2. B10M bLAr P-78 Gas- 3/4" .12. Four Burner Hot Plate 3/4" 430' W51 Note 14 7. wow bush P-25 Gas, 3/4" 412" Grill 3/4" .30' 4054 Note 14 2. 620M btukr P-30 Flow Sink 2" .0" counter Sink 1-1/2' .24" V13 Half Grate Top P-31 Flow Sink ,2' •0" A Food Winner I' .29" V64 Half Grate Top B Gaunter Sink 1-I/2" .24' WW C Refrigerated Base I' •8" 4065 D P Flow Sink 2" 40" A Silver Soak Sink 1-I/2" .28" B Glass Dunn Birk 1-IR" .28" P-33 Hot and Cold Ulster /2" 42' Corner Sick IQ" .36" P-34 Flow Birk 2' .0" A Counter Birk 1-1/2" .24" nw/ B Ice Tea Dispenser 1/2' -36 In C Coffee Maker 1/2' 436" P-35 Hot and Cold aster 1/2' 412" Counter Birk IR' .36' '013 P•36 Cold Luster IR' 4124 A Soda Dispenser U2' 42" 4082 B water Filler In' .36" 4063 C tee Tea Dispenser 114° 436' 4085 P-31 Flow Sink 2" .0' A Dipper well 1/4" d0' VW Half Grate Top B Hot Cocoa Dispenser VY .36" 4061 ' C Flavor Ralf V2' 430" V% DI Ice Cream Cabinet I' 42" 1094 P-38 Cold Luster /2• 412" Coffee Maker 1/4' .36" VW 14-31 Hot and Cold Luster in. 42' A Sink IR' 436" 410 Cold Ghly B Water Filler 1/2" .36" W83 C Ice Tea Dlepereer 114" 436' AM P-40 Flow Birk 2' -On A Soda Dispenser 1' 4" 4082 Half Grate Top B Water Filler I' •30' W3 c I Cold Beverage Plop. 1/2, .36" 4a54 Variry w/ S.ppller D Juice Disperser In' 36" W6 Verify w/ Supplier P-41 Flow Sink 2" .0" A Soda Dispanss - 1' 42" 4087 Waif Gate Top B Water Filler 1' 436" 4L83 C Ice Tea Dispenser 1/7, +36" em _ P-42 Flow Sink 2" 40" A Sink 1-1/2" 24" 110 Half Grate Top 8 Luster Filler I• 436" 4083 ClIce Tea Dispenser IQ' 436" 4085 01 Ice Bin 1' 44" MM P-43 Cold Water V2' 412" A Soda Disperser IR' 1 412" 0082 B water Filler IR' d6' OM3 G Cold Beverage Plop. 1/4" 436' 0064 D Ice Tea Dispenser 1/2' .36" '0B5 P-441 Hot and Cold Water IR' .12" A Dipper Wall 114" .36" 40% B Hot Cocoa Dispenser V4" .36" 4081 C Coffee Maker 1/4" 436" •BOA P-45 Hot and Cold Worts 1/2. 412" A Food Warmer 1/2, 4401 4164 Hot Ukter Onl B Counter sink 1/2' 436" 4a62 P-46 Floor Sink 2" 4" A Hot Food Ukrmer I" Q8" '908 B Ice Pan 1" 48" '855 P-41 are • P-46 Not and Colt Meter 17' •12" AlBirk 1/2' 4364 0110 B Ulster Filler Iq' .36" 4083 Cold Cnl P-49 Gas ' 314" 412. Steamer IA' 430' 4043 Note M 4 2. 788D00 P-50 Gas ' 1/2' .12" Convection Oven in, .30, 4041 Note 4 4 2. 801000 btuhr P-51 Gas • in, .12. Convection oven 1/7' •66" 1041 Nob 4 4 2. WOW btukr P-52 Direct Drain 1.1/2" 46" Mop Birk 1-1/2' .12" 114 Verlry w/ supplier P-53 Hot and Cold Water 112' .12" Mop Birk 1/2' .30' MI4 Verify w/ supplier P-54 Floor Sink 2" 40" A Sink 1.1/2" .24" NO Half Grate Top B Water Filler V 36" IM3 C Ice Bin 1' .24" Mn P-55 Floor Birk 2" •0" A Ice Pan P 428" 1 -NA B Ice Pen I' 426" 089C C Ice Pan 1' .28" 'BSA DI Soup alarms Ina Q4" 824 P-56 Spare ' P-51 Floor Sink 2" .0' A Hot Food Warms 1' 428" 1BBM B Hot Food Warmer 1' .28" 0906 P-58 Flow Sink 2" .0' A Hot Food Warmer 1' .28" -0A B Hot Food alarmer 1' 428" •SOB P-55 Cold Ulster 112' Q. Coffee Maker 114" .36" 11 REFRIGERATION ROUGH -IN EX'G COOLER PI02 PB3 FAST Il'-9 comecl with R-01 Refrigeration Lines Noted DFA Ula kt In Peszs:Suctton 1/8" 415" •0439 I Inter :Liquid 3/8" 410" 4M remot e rnhigeration FLUB 5INe FLAN <ITCHEN _1 a _7 . C {� I iu;i a SERVICE :p i it I I P23 �I I -I Ili F'25 R4 C `71 j .o Wig .a^1� L SERVICE 4-J BUFFET E P39 PINING ENERr4L PLUI" iBfNG NOTES M I ALL OUTLETS AND CONIgGTICNS SHOWN RELATE 10 FOOD SERVICE FIX1l1RE5 AND EGUIFMENr CNLT. REFER TO Al7GHITECTURAL/1'ffGaA1dICAL FLANS FOR ADDITIONAL REQUIRErENrs Arm IrFORIanoN 2 THIS, PLAN IS NTErmED TO SHOW ROUGH-M LOCATIONS, COidJEGfICN 511E5, POSITIONS, NEKsHTS AND LOADS REQUIRED UNTN FINAL CGNECTIONS. ALL Dp1EN51CN5 ARE TO CENTER FROM FMI544ED BOOR WALLS. 3 FINAL COMNECTICNS TO Bf BY PLII'iBp'Ye DIVISION, MCLUDIN,'i RELMIIRED MATERIALS. 4 ALL WOW, IS TO BE PERFORMED M ACCORDANCE WITH ALL CURTkT17 CODES L AND AS SPECIFIED BY THE PLUMBMG DIVISION- 5 PLUi'®MG DIVISION TO MTERf.GMECT DISH MAGHME AND BOOSTER CATER WATER TYPE VENTILATORS WITH C04T1a0L PANELS AND UTILITY DISIRIBUTICN SYSTEMS W/ EQUIPMENT A5 PER MM9FAGNTa'ER5 INSTRUCTIONS WHEN APPLIG48LE 6 ALL VENT PIPES ARE TO BE CONGEALED M WALLS OR COLU?! CHASES. USE LOOP -VENTS FOR ISLAND FIXNRES. l ALL EXPOSED PIPIr15 AND FITTp•YSS TO BE CONGEALED M WALLS OR COI CHASES. USE LOOP•vENTS FOR ISLAND FIXTURES. K , 8 ALL LMES ROUTED T'r1ROI1CiN EQUIPMENT SHALL NOT MTEFFERE WITH THE RJIENDED USE OF OR SERVIGMG OF EQUIFMt?TT. 9 PLU'BNG DIVISION TO HlTddISN AND MSTALL THE FOLLOWMG: A ALL WATER WASTE, GAS AND STEAM SERVICE i0 PONT OF RWGN-M AS SNIOIIN ON THE PLAN. ROIYsH-M5 TO EXTEND 4' CUT OF pkLLS AT THE FEIGFiT INDICATED. BOOR ROUGH -INS TO STUB 2'ABOVE FMISHED FLOOR OR CURB. ALL OPENMCiS ARE TO BE SEALED WATER TIGHT. J B PFtEssllR£ REDUCMG AND/OR REreuLATMG VALVES FOR DISHWASHERS, BUSTER HEATERS AND AS OTHERWISE NOTED. C ALL FLOOR SMKS, COMPLETE WITH TOP GRATES AS MDICATED AND REMOVABLE SEDIMENT BUCKETS, SET FLUSH WITH FMISNED FLOOR UNLESS NOTED OTHEFSUSE D ALL WASTE LINES, DIRECT OR pJDIRECT. MAINTAIN DRAMS AS HIGH AS POSSIBLE ABOVE FLOOR ALL WASTE LINES SHALL HAVE ADEQUATE GLEAM -OUT PROVISIONS. N E MDIRECT WASTE LINES FOR WALK -MS PITCHED 10 WITH A'P' TRAP AT END OVER FLOOR SW COPPER DRAM LMES ARE NOT ACCEPTABLE M WALK -MS. F HEATER TAPE WITH 36 WATiS/LMEAL FOOT OF DRAIN LNE AND MSULATIGN OF ALL DRAM LINES MSIDE FREEZER COMPARTMENTS. G ALL RE(:11RED GREASE TRAPS AS SPECIFIED BY THE ARGHITECNRAL/ MEOIANICAL PLANS. H INSTALL FIRE CONTROL GAS 541T OFF VALVE(5) AS SUPPLIED BY THE FIRE PROTECTION SYSTEM CCN1RACi0R -- I I YAOJIM BREATHERS AS REGllIRED EXCEPT FOR TNCSE F'Fc10YIDED WITH , DISPOSERS. J M5l1LATI04 ON ALL STEAM, NDi WATER Arm CONDENSATE LINES COLOR � CODED AS PER APPLICABLE CODES. , - _ K GLEAN CUT VALVES FOR STEAM,POENSAIE AND AIR LMES. A 1- ABBREVIATION $-?L'I50I, DESCRIPTION NW �1 NOT WATER ROUGH -IN AND CONNECTION CW 0- --b COLD WATER ROUGH -IN AND CONNECTION SERVICE III o-� MDIREGT WASTE AND CONNECTION W o--O DIRECT WASTE AND CONNECTION G 0-­0 GAB ROIIGN-IN AND FINAL CONNECTION SS 6­� STEAM SUPPLY ROUGH -IN AND CONNECTION SR 0­0 STEAM RETURN RDl1fiH,IN AND GONWECTION FS ® FLOOR SINK WITH APPROPRIATE GRATE PINING FD ® FLOOR DI PLUMBING ROl1CsH.IN /FINAL CONNECTION SCHEDULE CONTINUED ROWH M CONNECTION REMARKS RI• TYPE 517E HGT • DESCRIPTION SIZE REMARKS P-6 Flow Sink 7" .0 A Synp Warmer I" Half Gate Top. B °vOUP Warmer I" P-61 Hot 1 Cold Water IR" .12" A B Syrup Warmer Sap warmer V2' V2' 1-28'0114 Cold Water For Future Fleet Correct Not Ulster OnlP-61 Fat Water IR" .17" Sap Warmer In' P-63 Flot Water IR` Stub Not Food Wenner V7' .78 ia90 (2) Each Connections. P-64 Hot wets I!2" Stub Not Food Warmer IR' QB" 4a'e0 f2) Eech Connections. P-65 Not wets /2° 417" Not Food Warmer V7' QB° 4090 PIOI Gee • 3/4" .17' A Pizza Oven 3/4" 30" FF-2 Note 14 7. 40l300 15TU4 B Plae Oven 3/4" «48" FF-2 Note 14 7. 40p00 61114 P101 Direct Drain I-112" •I7• Nord 91nk I-1/7' .IB° FF-B verify with supplier P103 Hot and Gold wets I!1" .I2' Nand Birk I/2" 430' FF-8 verity with {uppaer 1*I04 Floor 91dc 1" .0' Chinese Range I-V2n 417' 4FF-6 1-05 as • 1-I/4" 417" Chinese Range I-I/4" .17" 4FF-I5 Nola 14 2. K26C0 B1W4 PI06 Not and Cold Ukter IQ" .12" Chinese Range IR" •30' 4M-0 (7) Ea. Cam Pi01 Not Uead PIOB Flow Sink 7" 40" Thee -Comp Sink I•117' •18' ff44 PI09 Hot and Cold wale IR" .17" Mes-Comp Birk I/2" .36" 'FF-14 P•110 Fbl ulster IQ" .U" A Food Worms I/2' .78' ff-7 Food Warmer IR' .18' 4F-7 PIII Floor Sink 2" 40" A Food Warmer I° 4m-2 Food Weimer In 4�-7 PII2 Flow Sink 2" 40" Food Warms I" d-28' 'fF-16PiB Not wets IR" Btub Food UJanner U7' 4FF-Ib •Gee Note M: All gee comectlone to be by quick disconnect. Verify gee type 4 altitude end adjust as required. Note 4: Gee lines to be connected by quick disconnects from main gee Ilse located under return air d^aee. 14 ID No. I REVI5IONS/51.1E3MISSION5 Date G a design build company 60 WEST 890 SOUTH, BRjI�G�HAM CIITY, UTAH84302-8I78 (801) 734/-8407 B JONAME V T I Q�/--1 Y I 1- sr. LucIE, FLORIDA DRAWING TITLE FOOD SERVICE EQUIPMENT g , PLUMBiNG fiREQUIREMENTS SEAL DF2AU)N PROJECT NO. DID CHECKED SERIES � 1_15-208-L-02 REVIEWED DRAWING NO. ' �2' DATE SCALE NOTED-- 131 I� 2 '0 I - - 11 I 12 I 13 14 I Y 111 L K J N C7 1� E 1J L IJ ELECTRICAL RoLnS 4 IN / FINAL CONNECTION 5CHEDULE F6CUGH N CONNECTION I REMAFaCb RI' TYPE WIT N7. DESCRIPTION VLT/CY/P LOAD 0" ITEM E-01 Junction Box •48" Ice Maker I10-208/60A 1625 amp J-Box "M Correct w remote M. E-02 Jvotlon Box .06' Fraezm Coil 208/60A 133 amp J-Box 4009 Cacrrecn WithFAMOUS rN. E-03 Junction Box •106' Cooler coil 120/60A 5.1 amp J-Box '00B Larriact with rerola ref.1D01 As Par E-a74 .kmietlon Box 406' A WeYc-In Box (Cools) 115/60A 0B amp J-Bax 1rJ04O Dear A Iighta B Wak-In Box (Cools) 115/60/1 OB amp J-Box 4006 Heated air vent E-05 Junction Box 49W A Ita9t-In Box (Freezer) 115/60A 1.2B amp J-Box 4006 Door A 4g^u :- Wslk-In Box (Fraazs) 115160A 0B amp J-Box r006 Heated air vent E-O6 Cultist 43" Fc"d Cutts 115160A 14b amp COP V28 E-0l 0AISUflex) SUh slice 115/60A 1/3 HP COP 4031 Note 9 E-08 Qnlet (flea) Stub Convenience Outlet Ilru/b0A Yrerify CAP 10i9 NOW 4 (2) each locations. E-09 JurCtIon BAR stub Mixer 2OW60/3 3/4 HP J-Box 4032 Nose R. E-10 Outlet 48" Convenience Outlet 115160A verify CAP 4021 E-11 kmtlon Box DFA Food Lights 113leCA OW matt J- Box 4039 sae oElle�clttrriicral correct Plans for IIa9Ma Food cW,L E-12 -AAAxkmBe(W 48" TIH Kettle 206/60A 54b amp J-Box '044 Note V E-13 Oule .I0. Steams 115/60A 100 matte CAP 4043 E•14 Outlet (flax) •18" Convenience outlet 115/60A Verify GAP 3 NOIS 9.(2) each canetlon. E-15 Outlet .18" - Pressure Frye 110/60A 5 amp CAP a0441 E-16 Outlet Convection Oven 115/60A 9 amp CAP 4041 E-11 outlet Convection over 115/60A 9 amp CAP 9041 E-18 Junction soot JA Hood Lights 115/60A 1000 Watt J- Box '050 Sae Electrical Plea For fan req htscorract lights Food controls. E-19 Outlet Frye Filter 115160A I/! HP GOP 4052 E-20 outlet: Fryer Heat Lamp 115/6011 4B amp CAP V5,2 E-21 Outlet •18. Refrlgsated Base 115/60/1 1 65 amp CAP V% E-22 Outlet .20-1 Refrigerator 115160A 2A amp CAP 00" E-23 outlet .12' Microwave Oven 208/60/1 20 amp CAP 4069 E-24 Outlet 46" Waffle Iron 120/60/1 VWIN CAP W02 vsify load With auppller. E-25 Gullet -.W Waffle Iron 120160A Verify CAP 922 verlfy load with supplier. E-2(a outlet' 101. Rafrigsated Cabinet 120/60A 4 amp CAP 4053 E-21 Junction Box .18" Food Warmer 208/60/3 145 amp J-Box W64 Intmwmect controls. E •28 outlet •12' Geese Melts 20B/60A 1400 watt COP 4010 E-29 AAdiaim MK,I M, Heat Lamp 120160A 1800 watt J-Box 4068 � opqnmaqq side paw— undar pplaei•"if to Juictidn box at Mal lamp. E-30 cutlet .W- Waning Holding Caorat 120160A 24 amp CAP M26 E-31 Outlet 40' Toaster 208/60A II amp CAP '061 E-32 Outlet 48" Coffee U)armer 120/60A 260 watt CAP fiO3 E-33 Outlet .18" Roll Warms 125/60A a amp CAP V63 E-34 Outlet (flail &lib Roof Box 120/60A 10 amp CAP 024 Note 1 E-35 Jurctlon Box .I9" Rafrlgerated Basa 115/60A .4 amp J-Box W65 Carract w/ remote ref AM E-36 t0ullet 48' Convenience outlet 115/60A Vmlfy GAP 4067 4091 (5) each locations4012 E-31 Not Ikad E-38 Outlet .I6" Grooved Grill 115160A 4 amp C41- W53 E-39 Junction Box •IB' Freezer Base II5/60A 4B amp J-box W60 Correct w/ remote ref r001 E; 40 Outlet .90" Refrigerated Cabinet 115/60A 2A amps CAP 0125 Contact w/ ramous ref. WI E-41 Outlet 48" Toaster 208160A• II amp CAP 4018 n (3) each locations, E-47 Outlet •18" —Roll canner 125/60A 8 amp GOP 4016 E•43 Outlet 45" Ice Tee Disperser 115/60A 15 amp GOP 4065 E-44 04let 401. Grill 115160/1 4 amp CAP 4049, E-45 Outlet .I9" Grill 115/60A 4 amp CAP 4054 E-46 Outlet (flex) Stub Refrigerated Base 115160A 4 amp CAP 4091 Nob 5 E•41 Outlet 46W Coffee Makm 00-205/ 60A 30 amps CAP 430 vslfgg toed with Fie: 4 Wee E-48 outlet IW soda Dispenser 120/60/1 6 amp CAP AM £-45 cutlet .I6" Soda Nstan•future 120/60/1 Verlfy CAP Future requirement. E-50 Cutlet .18. Soda Dispenser 120160A 6 amp C4P 4082 E-51 Outlet 45" Cofraa Brewer 16200-206/ 30 amps CAP 4080 Verifyy load with supplier. 4 Wirer. E-52 Outlet 48" Coffee Maker 120-208/ 60/1 20 amps G4P WA Verify load with supplier. 4 Wire E-53 outlet 48" Hot Cocoa Dlspanear 120/60/1 14 amps GAP 4061 Verify load w/ supplier. E-54 Outlet 48" Mlk Dispenser 115/60A 14.6 amp CAP 4081 Varlfy load W/ suppllar. E-55 Outlet I.W. Melt Mixer 120/60A 3 amp CAP VW E-56 Outiat .12' Microwave 120/60/1 1400 watt CAP 4099 E•51 Junction Box .IB" Ice Cream Freezer 115/60A 33 amp - CAP 4094 E-55 Outlet stub Coffee Weimer 120160A 260 watt CAP e03 Note %. (2) aaoh location. E-59 Outlet 48, converlence Outlet 120160A Verify CAP W13 (3) each location. E-60 Junction Box .18" silver Saver 115160A 5 Amp CtP 4014 vwirg load E-61 ,Alndlon Box •'8" DleFwasMr, Motor 208/60/3 143 Amp J-Box 4011 E-62 Junction Box W. Dishwasher, tank Feat 208/60/3 44.9 amp J-Box eon E-63 Junction Box .18" Booster Heater 208/60/3 21 KW J-Box 4023 RAxvlda Diecorrnxt E-64 Junction Box Ve Remote ReFrlgaration 200/60/3 90 amp J-Box owl vsify location E-65 Outlet 48" Juke Dope err 115/60A 20 amp CAP AM Verify load w/ supplier E-66 Outlet 45 Convenience Outlet 120/60A YwIN G4P 'IR (4) each location E-6l Outlet (flex) 48" A B C F'09 stem Gash lets Pra- Register PrIrRs Verify vaniry fill aae'�llas awcirial 'dninetc end elioo crawxps and Alec lcal plan' for Sun tan rsgwlrwa Notes E-66 Outlet Stub Call system IV2160A 1 amp CAP fib Note'9 Outlet (flax) Stub Code and Fold 220/60A 26B amp CAP 115 Note `1 utlet 48" Ice Tea Dispenser 115/60A 15 amp CAP 4085 Verify load w/ supplier. cutlet 45" Hot Fudga Dlsp. 115160A 350 watt GAP IN Junctlon Box Stub Hot Food Wanner 205/60/3 5B Nip J-Box OWB (2) w location. karcarnect Controls. outlet .12' Rafrig. Dlepiay Case 15/60/1 55 amp CAPJunctlon I Box .IB" Soup Warmer 20B/60A 10 amp J-Box 4024 Junction Box Stub Hot Food Weimer 208/60/3 103 amp J- Box 50A (2) w location. karcorract Jrdla Ba FIaU W Tilt Kettle 208/60A 54b amp J-Box '044 Note'4 a Outlet 48" Ice Tea Disperser 115160A 15 amp CAP 4085 verlfy load w/ supplier Outlet 4V Cold Beverage Dlsp. 115160A 10 amp CAP '054 Vmlfy load w/ supplier Junction Bp .I8" Warmer 120/60A 10 amp J-Box 908 Interconnect controls Outlet .Is' Ice Cream Machim 203160A 40 amp GAP AID E-81 Junction Bo 418" Hot Food Wormer 200/60/3 5B Am J-Box '90B Interconnect controls E-52 Junction Box .W3" Soup Warmer 120/60/1 10 amp J-Box 4024 kitmcornect controls E-83 cutlet 401, Range oven 115/60A 9 amp GAP 0042 E-84 Outlet •IB" Fryer 115/60A 5 amp C4P 4058 E-8F Outlet •IB" Fryer 115160A 5 amp CAP 4056 -BOX O JUNCTION BOX ROUGH- IN AND CONNECT -BOX (JC JUNCTION BOX PROVIDED IN EQUIPMENi )CO DUPLEX CONVENIENCE OUTLET 'O-I ® POLUER OUTLET, I PHASE :)CO) f DUPLEX CONVENIENCE OUTLET PROVIDE IN EQUIPMENT PO-1) (C POWER OUTLET PROVIDED IN EQUIPMEN O $ FLOOR OUTLET, FLUSH OR PEDESTAL UJ 4; SUATCH 'P ® VAPOR PROOF LIGHT )FA -<)— DROP FROM AIE5OVE, TYPICAL EX'G COOLER ELECTRiCA4L ROLeH- IN I=LA N <I TCHEN 3 4 5ERVICF BUFFET ID NI DINING GENERAL ELECTRICAL NOTES M I. ALL OUTLETS AND CONNECTIONS SHOWN RELATE TO FOOD SERVICE FIXTURES AND EQUIPMENT ONLY. REFER TO ARCHITEGTURAL/MECHANICAL PLANS FOR ADDITIONAL REOWIRET-ENTS AND INFORMATION. 2. THIS PLAN 15 INTENDED TO SHOW ROUGH-N LOCATIONS. CONNECTION SIZES, POSITIONS, HEIGHTS AND LOADS REQUIRED FOR FINAL CONNECTIONS. ALL DIMEN51ONS ARE TO CENTER FROM FINISHED FLOOR AND WALLS. 3. FINAL CONNECTIONS TO BE MADE BY ELECTRICAL DIVISION, INCLUDING REQUIRED MATERIALS. 4. ALL WOW IS TO BE PER OR IED N AGCOFDANCE WITH ALL CURRENT "ODES AND AS SPECIFIED BY ELECTRICAL DIVISION. 5. ELECTRICAL SYSTEM TO BE: 120/108 VOLT 1/3 PHASE _ &V HERTL 6, ALL ELECTRICAL WORK FOR FABRICATED FOOD SERVICE EQUIPMENT SHALL BE COMPLETELY WIRED BY KITCHEN EQUIPMENT DIVISION TO A JUNCTION -BOX OR PULL -BOX MOUNTED ON THE EQUIPMENT IN AN ACCESSIBLE POSITION. FINAL C.ONNECTICN5 TO EQUIPMENT AND ALL ELECTRICAL WOW FROM PANEL BOARDS K TO BE BY ELECTRICAL DIVISION 1. ELECTRICAL DIVISION TO PROVIDE CONDUIT AND WIRING, INSTALL ELECTRICAL COMPONENTS PROVIDED BY KE.0 AND INTERWIRE BETWEEN THE FOLLOWING: A REMOTE REFRIGERATION EQUIPMENT TO EVAPORATOR COILS. B. CONTROL PANELS TO WATER TYPE VENTILATORS AND EXHAUST/SUPPLY FANS AS PER MANUFACTURER'S NSTRUCTION5. C. KITCHEN EXHAUST HOODNENTILATORS TO FIRE CONTROL SYSTEM AND SHUT OFF5. J 8. ELECTRICAL DIVISION TO PJW15H AND INSTALL THE FOLLOWING: A ALL JUNCTION -BOXES, ELECTRICAL OUTLETS, COVER PLATES, SWITCHES, AND CONDUIT NOT BUILT INTO FIXTURES OR EQUIPMENT. ALL OUTLETS, JUNCTION - BOXES, COVER PLATES N D15HROOMS OR AS INDICATED MUST BE VAPOR PROOF. B. ALL FL'U65 AND COF05 A5 NOTED. ALL CORDS SHALL BE NEMA. RATED AND U1.APPROVED. 1 C. SHUNT TRIP BREAKERS OR DISCONNECTS FOR FIRE CONTROL SYSTEM SHUT OFF OF } EQUIPMENT BELOW HOODSNENTILATORS AS REQUIRED BY NPPA-56 LOCAL CODES. D. DISCONNECTS OR OTHER DEVICESkQUIRED BY CODES. 9. ALL ELECTRICAL WOW TO ROUGH-IN5 TO BE CONGEALED IN AND SET FLU514 WITH THE FINISHED WALL AND/OR FLOOR No. I REVI5ION5/SU5M15510N5 1 Date G a E N C a design build company 50 WEST 990 SOUTH, BRIGHAM CITY, UTAH 8'4302-678 (801) 734-6407 JOB NAME FLYING J TRAVEL PLAZA ST. LUCIE, FLORIDA DRALJING TITLE B (FOOD SERVICE EQUIPMENT \ ----- -_ DFA: Drop from above/ CAP: Cord and plug/ J-Box: Junction box/ ELEGTRICAI REQUIREMENT,,:) Stub: Stub up from Floor/flex: Utilize Flex to final connection. \ Note fi: Run flex from stubbed rough -in J location to outlet mounted on work table. SEAL DRAUJN PROJECT NO, J Note a2: Run flex from stubbed rough -In locatlon to Junction/alectrical connectlon at equipment. CASHIER J Nute -,: Rrn flex from rough -in location to outlet mounted In backeplaeh. DB Note 04: Run flex from rough -In location to Junction/alectrical connection at equipment. , CHECKED SERIES Note 5: Run flex from stubbed rough -In location to outlet mounted In backepla6h of counter. \b m ,J EII3 / Note '6: Run flex frostubbed rough -In location to outlet mounted In counter base. RL15-2�8-L -tat EII3 I' REVIEUJED DRAWUIN6G NO. . F I =DATERI =J . F;;� A " = I'-0 � SCALE NOTED 13 lm 11 12 13 14 ELECTRICAL ROUGH IN / FINAL CONNECTION SCHEDULE - CONTINUED ROUGH IN C20ECTJCN REMARKS E100 ' Ref. Pine Table 1"""1 V3 HP. CAP FF-I E-101 ' Ovan 120/60A 1 4 p CAP FF-2 E102 . Ovan 12m/60A 1 Amp CAP IF -2 E03 aUsad A Hood 120160A 500 Watt J•Box FF-3 See Electrit I Plan. knacorrect Iq,U to fan hood controls. E104 E105 ' Conv.Outlet 120/60A 10 kip CAP FF•1 (4)ea. loatian E101 Outlet 48 Thermal Shelf 120/60A 4.2 Amp CAP FF-9 (2) as, location Eftoutlet (Flat .I5, Cash Register Verify Velfy COP fF•tl Nds i. seer ad slat er}saUa ra der aid rts. l piss fa auct r�e wreeat EIN Outlet 48' j Ref Prep Table 115/60A V3 hp. Cap 4F-FI EIV J-Box (Fla) •I8' Fist Food Warmar 120/60A 10 Amp J•Box 4f-16 kaecornect corarois. Note EIII Outlet Buh Freezer Base 15/60A 6 Amp CAP 'FF•20 E112 Not Used - EII3 Jxctlon Box .19' Food Wane 206/60/3 H5 Nip J-Box AT-23 W ealoatiait Wtecomect controls 1 2 3 4 5 6 8 9 10 11 12 1 13 14 71 MATERIAL KEYING LEGEND I r T I I CONVENIENCE STORE EQUIPMENT [REFERENCE LIST — BAJQJET I C-I SLUSH MACHINE C-2 POPCORN POPPER • I — C-3 4' ELFGASE C-4 HOT FOOD MERCHANDISER G-5 SAFE -- C-6 SOILED TOWEL CART C-1 6' CIGARETTE RACK C-8 NOVELTY CASE T T T - I L --� C-1 HOT DOG MERCHANDISER I C-11 CAPPUCCINO ••,• C-12 MICROWAVE ' ® _ _ C-13 ICE TEA MAKER C-14 CUP DISPENSERS ® J J 13 ® ® 11 - I L _ _ _ ___ G-I6 �NOE AK .. R ® 0 ®irr C-11 ICE CREAM MACHINE Mt MAINTENANCE C-IS DECAFFENATED COFFEE WARMER E f STORAGE x _jK /'l� N __ n ELECT. - 33 _ - I G-le POST MIX DISPENSERS N Ma © MEGH. /0 lJ ©I i -.I ; C_2m DEND��AAP��LEAg SHELVES ® J 12 J I ® ( ) I I - -I - I C-23 3' X 3' DISPLAY CASE_ K \� __ C-22 •'• NOT USED •••' DISPLAY ® J 0 JEY:To ® 3 DISH. C-25 ELECTRON C DISPLAY CASE STORAGE - TER I C-26 3 DOOR FREEZER C_ 2 WALK- IN COOLER E _ = -- �- %'�ZZAAIME --- I ® �_, I. C-28 COOLER DOORS HALL J - 1 .. C-30 •.•. NOT USED •••• A,DOVE C-211 DONUT CASE J ® J 8 g R'/ _ H `� ELE -- F - C-31 ICE MACHINE - ^ l LC-32 COLD STORAGE SHELVINGT15 U® C-33 - ' NOT USED •••• I G-35 LID t DCONDIMENTT TRAY _IR HALL I C-36 BAG IN BOX RACK FOR P05TMIX .. - - ___ I FUEL DESK ® ETMG REST. I ] EQUIPMENT REFERENCE LIST --_ MENS J (� Ms I I OFFICE l .. 4 __ . l I HALL Imo] �' ® I r- _.- g _ F-I P.O.S. TERMINALS MI5 _ F-2 TELEPHONE PRINTERS - ( ® - - I � <ell -_ __ -_ ____ F-3 tELEPHONE (CASHIERS) 2IM Iegos F-4 ADDRESSOGRAPH CARD IMPRINTER F-5 AMERICAN EXPRESS IMPRINTER N I I D - - ---- - ( [ ] — 77 F-6 MICROFICHE READER E J _ I BI.IFFET [� F-8 TS IMPRINTER -� ENS _ /^� E ��y7 - - R _ AREA I, I F-S COM- CHECK PRINTER 'Pill � - _--- \YJII - - ,--- /-''ems; FREEZER L © B _ F-11 TRAN5GEIVER SDI - --.- F-10 COM. DATA CONTROL 4 ��I ® F$ MENS / ® ITRE S I F-12 SCALE PRINTER STATI F-I3 SCALE DATASOURCE ® RESTAURANT - F-14 P-OS. CPU ® I qp F-15 P-O.S- WORK STATIONS � T F _ _ I I I STORAGE �. __ (�.� _._ _ I I r� ❑ [�9 v I \ � L T- -- 1`115CELL,4NEOUe ® EQUIPMENT REFERENCE LIST Cs K t N5 COOLER I - M-1 COIN OP. DRYERS C N G31 --- - - - _-®-� - I WASHERS M-3 MONEM-2 COIN Y SAFE W/ HOPPER L RY _- _.� ---- M-4 CLOTHES DRYER M-5 CLOTHES WASHER M-6 READER BOARD CONTROL COMPUTE LULL-_ _-_ R M-1 FLYING J WALL MAP M-8 STEAM GLEANER J I cjf M 9 18' CEDAR Sf-IARREL TRASH REGEPTIGAL e WALK-N COOLER ER FART FOOD M-10 12' CEDAR BARREL ASH URN J M-II OFFICE CHAIRS W/O ARMS DRI MI4 MI5 L ® ® ® - --- M-12 2-DRAWER LAT. FILE LOL_ _ _" M-13 4 DRAWER UPRIGHT FILE M — — ._ __— _.-___.__ -- __. M-14 DESK Eli 05�. _ _ _ _ I M-15 OFFICE CHAIRS W/ ARMS M-I6 SIDE CHAIRS '- OFFICE - - - - - - --° --_--- j1_ - _ -_1 I I I M-I1 RAPIDPRINT TIME TAKER My , -D '--I_-�' -- M-111 WALLL MOUNTED MARKER BOARD I 0 Q M-211 A.TM. M-21 COPY MACHINE - 2 � M-22 TIME CLOCK ,� f f IC 1 M-23 TIME CANE RACKS _.! LI I I M-24 PROP - 6'-1 U1' �. 4,_ 0, 4,_m, 0' d,_m. �. { _®. , O' 4'^O' ®. _5. I I 10'-0' I 5'-6 V4' STAU T ) f- 1 -- n 25 1�3 vc , L _J \ GA R PLAYER ----------_------ --- -- _ - -- - O'M-21--------- NOT USED ------------ .� _ -- - M-28 --------- NOT USED ------------ M-21J EMPLOYEE LOCKERS \ O < I I M-30 INTERIOR FLOOR SCRUBBER CAME HALL - ROOM 6 \ FAST FOOD -�� - _ 5'-4 I!1' M-31 TON SERVICES WAITING ® t ST �\ 00 0SEATING AREA VEST. ® I 8 151aED 5RA55 HAN RAIL rum 1 7 1 1 WI 3' F'05T AT 6'-O'c c. mAJ(- 1] ®EAtNG AREA o o RAIL ISHEO BRa sc TOP H a H e Q C C 10 A HALL® N JAN. CM No. REVISIONS/SUBMISSIONS Date N I R A ® (— — a _] �, g MEWI I C 's 3 31!C t.. G 1 CrI LElI s aoL REFERS To BUILDING JOB NAME Ea design AM build Company 60 WEST 990 SOUTH, RIGCITY, UTAH 8 02 878 (801) 734 8407 — -- — — -- = CASHIER AREA 1 1 ,,`, I SIGN PANEL TYPES, SEE SPEC. FL 1' f NCB J TRAVEL PLAZA ® SECTION 10440 IL43 a � ®1 I SAINT LXIE, FLORIDA _ DRAWING TITLE F4 FACILITY FI FI F EQUIPMENT PLAN 77� I SEAL DRAWN PROJECT NO. Si84 ©f M JKP L — -- — — — — — — — — —I CHECKED SERIES -- --� El � �-- — —s rt� DK L15L-AI 15 TRASH REGPTICALS PROPANE $GALE REvIEWED DRAWIWC NO. AT THE FUEL ISLANDS TO BE LOCATED WD A 4 SEE SHEET GIJ AT T44E PROPANE DATE ' J DISP. • 09-04-51 SCALE ? 3 4 5 6 8 9 10 111 12 13 1 14 1 2 3 4 5 b 7 8 9 10 11 12 13 14 i DOMESTIC WATER FIXTURE UNITS 659 = 265 GPM (FLUSH VALVE ) (INCLUDES 100 GPM IRRIGATION) GENERAL NOTES CONT. KEY NOTES TO SHEET P-1 PLUMBING SYMBOL' SCHEDULE /=� (IRRIGATION WILL BE DONE IN OFF PEAK HOURS.) HIGHEST FIXTURE LEVEL ABOVE WATER MAIN = 10 FT. STATIC HEAD) 8 THE PLUMBING CONTRACTOR SHALL NOT INSTALL EXPOSED PIPING SYMBOL R \A I N nYPIGAU ( tO CONTINUED MAIN LEVEL PLUMBING FLOOR PLAN 1/P-2. SEE ISO 5HEET5 / PRESSURE AT WATER MAIN: 58 PSI; REGULATED AT 50 PSI; SYSTEM DESIGN: 50 PSI. (BOOSTED PRESSURE) ABOVE OR WITHIN THE CODE REQUIRED WORKING CLEARANCES OF M " - CW COLD WATER LINE ! ANY ELECTRICAL PANEL BOARD OR SWITCH GEAR (30' WIDE OR THE n M - - HOT WATER UN FOR Ew>wrT / / PRESSURE LOSS (STATIC HEAD) 10 FT x 0.43 = 4.3 PSI WIDTH OF THE PANEL, WHICHEVER IS GREATER AND 36" IN FRONT- 0 EXTEND 6" DRAIN LINE TO 5' BEYOND CONNECTION OF BUILDING DRAIN & CAP — HMR HW RECIRCULATION UNE LOCATIONS. / y / / PRESSURE LOSS THRU 4 ' METER AT 250 GPM = 5 PSI FLOOR TO COUNG). COORDINATE WITH ELECTRICAL CONTRACTOR. FOR CONNECTION AND EXTENSION TO UTILITY SANITARY SEWER MAIN UNDER - - — L / / PRESSURE REQUIRED AT MOST REMOTE FIXTURE = 25.00 PSI CIVIL CONTRACT. - - - - LINE UNDER L 13 3/4' / J PRESSURE LOSS THRU 4 ' BACKFLOW PREVENTER = 4.3 PSI O9 PLUMBING CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS HWR / ° / TO OWNER SUPPLIED EQUIPMENT REQUIRING PLUMBING CONNECTIONS. 0 GREASE INTERCEPTOR, SEE DETAIL (11/P-D2). SAN ANiTARY WASTE LINE IRFIOW FLOOR OR GRADE,SAN SANITARY WAS UNE a F OR (TYPICAL) / / / / SUB -TOTAL PRESSURE LOSS 38.6 PSI SEE SHIM 15 EQ IA / � g }{E 10 PROVIDE AND INSTALL MANUAL SHUTOFF COCKS AT ALL GAS SANE EXISTING SANITARY WASTE UNE ,. / kl/2• EXTEND $ DOMESTIC WATER LINE ENCASED IN 6" PVC SLEEVE TO 5' BEYOND VENT UNE d EQ I_> FOR EXACT ^ `/ / CONNECTIONS TO GAS FIRED EQUIPMENT. BUILDING PERIMETER. EXTEND &CONNECT TO YARD MAIN AS SHOWN ON CIVIL (TYPICAL) ( ) ) PLANS. DEPTH TO BE 36' BELOW FROST UNE. (ALL DONE UNDER THIS CONTRACT) C � . COND A C CONDENSATE UNE SIZED TODISCHARGE)_PLIJ�IN6 CONTRACTOR SHALL LOCATIONS. � \ SYSTEM DESIGN 50 PSI -SUBTOTAL PRESS. LOSS 38.6 PSI = 11.4 PSI AVAILABLE FOR FRICTION LOSS UP PIP RISER UP MEWED CEILING TOY' SEE `' L 11 UNDER FLOOR PLUMBING LINES SHALL NOT BE ROUTED UNDERNEATH ON PIPE RISER DOWN MEWED CEILING TO FLOOR EN511RE THAT ALL COPPER \ / T/ d EQ 15 FOR E>� LONGEST RUN OF PIPE : 800 FT. x 1.4 (FITTINGS) = 1120 FT. TOTAL DEVELOPED LENGTH FREEZERS. L SOv Gv - TUBIN6 ON TH15 PROJECT 6 / �/ / O LOGATIOW O5 2" DOMESTIC WATER LINE FROM INSIDE BUILDING TO ISLAND HOSE L V v U - vaL ALL vaL REAMED TO THE FULL INSIDE / PRESSURE AVAILABLE; 11.4 PSI / LENGTH: 1120 FT. x 100 FT = 1.0 PSI AVAILABLE FRICTION LOSS 1Q ALL WATER LINES LOCATED IN OR NEAR OUTSIDE WALLS SHALL BE RUN CONNECTIONS. DEPTH TO BE 36" BELOW FROST LINE. (ALL DONE UNDER SOV GV NC SOV GV NORMALLY DIAMETER OF THE PIPE OR / — V V N So BV NORMALLY CLOSED, gpT}{ THE INSIDE d ° / / J PER 100 FT. OF PIPE. BETWEEN WARM SIDE OF WALL AND BUILDING INSULATION TO HELP THIS CONTRACT). SOv GC SHUT-OFF NORMkME Gas COCK PREVENT FREEZING OF LINES. THE OUTSIDE MAY REQUIRE / / / -- - ----- 1Q EXCAVATION OF TRENCHES SHALL COMPLY WITH SECTION 315.0 OF UPC. 1' COMPRESSED AIR LINE FROM INSIDE BUILDING UNDERGROUND TO _y N UNIONREMOVAL OF THE BURR, / /� ? / N!D : WATER PRESSURE INFORMATION SUPPLIED BY 4 ISLAND SUPPLY POINTS. (ALL DONE UNDER THIS CONTRACT). v / PIPE SIZING BRAD COWER - FT. PIERCE UTILITIES � INSULATION SHALL HAVE FLAME SPREAD NOT TO EXCEED 25 AND A SMOKE PQT SS. & M . FL F VALVE �/ 11/�. (904)279-2242 + DEVELOPED RATING NOT TO EXCEED 450. C7� RISE WITH 1/2' COMPRESSED AIR UNE AND 1/2' COLD WATER UNE TO / t HYDRANT FLOW TEST 9-27-95 68 PSI STATIC R R GAUGE / \ / / DEMAND TYPE : FLUSH VALVE RESIDUAL PRESSURE = 54 PSI, 1180 GPM FLOW 1Q PIPE HANGER SPACING FOR PIPES LESS THAN 2" DIA. SHALL NOT EXCEED HOSE REEL BOX AT ISLANDS. SEE FUEL PIPING DRAWINGS FOR EXACT FIR GA / 6'-0' CENTERS. LOCATION. SEE DETAIL 8/P-D3. ■WTR MIR WATER METER / .. / / c GAS MtR GAS METER MAXIMUM FIXTURE UNITS PER PIPE SIZE AT 1.0 P51 AVAILABLE FRICTION LOSS PER 100 FT OF PIPE. / / , � GAS PIPING SHALL BE PRESSURE TESTED AT 10 PSI PER UPC SECTION (B� RISE WITH 3/4' COLD WATER TO NB3 AT ISLANDS. SEE FUEL PIPING TRW— RW RAIN WATER UNE ABOVE FLOOR DIESEL : / 'FLUSH VALVE }�' _ - FU's = 2 FU's 1' = 6 FU's ; tJ�' = 12 FU's ; 3 FU's ; 120a.3. PRESSURE SHALL BE MAINTAINED FOR A LENGTH OF TIME DRAWINGS FOR EXACT LOCATIONS. SEE DETAIL 9/P-D3. K G— G NATURAL PROPANE GAS LINE ISLANDS / / / �4' FIXTURES UNITS. 15' 69• 186' " 775� SATISFACTORY TO THE ADMINISTRATIVE AUTHORITY (MIN. 15 MIN.). WELDED K t}�' = 21 N's 2" = 58 FU's 2)F = 155 FU's ; 3' = 315 FU's ; 4' = 1668 FU's ; PIPE SHALL BE TESTED AT 60 PSI (MIN) FOR 30 MINUTES (MIN). L COORDINATE PIPING WITH UNDERGROUND FUEL PIPING THIS AREA (TYPICAL). Sw SOFT WATER LINE/ - DO NOT RUN PIPING UNDER FUEL ISLANDS. A a I o _ / / / NO SCALE 2 i t7 ALL GAS APPLIANCES SHALL BE CONNECTED PER UPC 1212.o. - - — — / / / WATER PRESSURE FRICTION LOSS CALCULATIONS C� R.V. SANITARY DUMP ISLAND STATION. 4' 0 PIPE WITH 4" DEEP SEAL _ _ = DW DEDICATED WASTE UNE 3/4,(TTr) 7 CLEAN OUTS TO BE SIZED PER, TABLE 7-6 SEC. 707.0 UPC. TRAP AND HINGED CAP. SEE DETAILS 11/FP-3 ON FUEL PIPING DRAWINGS SOV IN YB SHUT-OFFVALVE IN YARD X / / AND 10/P-D3. CAP TO BE SUCH AS OPW-269 WITH DPW �633-T-8075 FM FIRE HYDRANT r 4 "- 'F' °i•- r SYMBOL REFERENCE 1 VENTS UNDER FLOOR - OFFSETS HORIZONTALLY LESS THAN 6' ABOVE THE FIRE T CONNECTION / / I CONTINUED THIS PIPE ADAPTER. FLOOD RIM SHALL BE INSTALLED IN SAME MANNER AND MATERIAL AS WATER MOTOR WNG�'` �/ / / TRAVEL PLAZA BUILDIN 9 I I i SHEET 6EfERA1_ NOTE 5YM30L DRAINAGE PIPING. 11 EXTEND 4' PIPE 5' BEYOND PAD FOR CONTINUATION AND CONNECTION TO —�i-W PIV POST INDICATOR VALVE / / 1! I �~� I (EXAMPLE: NOTE #I) SANITARY SEWER PROVIDED INSTALLED UNDER CIVIL CONTRACT. POC POINT OF CONNECTION UTILITY WATER MAIN - SIZE/ / / J - I I N KEY NOTE STI-WL 22 THE PLUMBING CONTRACTOR SHALL PROVIDE & INSTALL ALL FIXTURES AND J - - - - / / 97F_ - J I lO # EQUIPMENT SHOWN ON THE 'P'(PLUMBING) DRAWINGS. 12 GAS METER AND SERVICE TO METER BY GAS COMPANY. P.0 SHALL MAKE - - _ - - - __ _ - _ - _ - (EXAMPLE: NOTE I) - - - . f- LITHITY CAS MAIN( / // _ L J - - SPECIAL NOTE SYMBOL O ONLY BALL VALVES SHALL BE PERMITTED TO BE USED FOR ZONE & AREA i ARRANGEMENTS FOR SERVICE. CONFIRM EXACT LOCATION. / /7 (EXAMPLE: NOTE #I) VALVES. CJ RISE WITH 1/2' COMPRESSED AIR LINE TO HOSE REEL BOX AT DIESEL ISLANDS. I DETAIL SYMBOL SEE FUEL PIPING DRAWINGS FOR EXACT LOCATIONS. SEE DETAIL 8/P-D3. EXAMPLE: DETAIL I, SHEET P-3) ALL TRENCHING SHALL BE THE RESPONSIBILITY OF THE INDIVIDUAL CONTRACTOR, COORDINATED WITH THE GENERAL CONTRACTOR, 14 MAKE GAS CONNECTION AT GAS METER. RISE NTH GAS LINE INSIDE BUILDING 3 hffiOL / 1 A3 SECTION SY�: SECT ON A, SHEET P-3) ' GENERAL NOTES INDICATED (*) SHALL SUPERSEDE SPECIFICATIONS. (15� FIRE SPRINKLER CONTRACTOR SHALL CONNECT TO TEE IN YARD MAIN IN THIS EXAMPAREA. CONFIRM EXACT LOCATION. ONER SUPPLIED EQUIPMENT SYMBOL A -I SEWER DISCHARGE SUMMARY WATER LOAD SUMMARY H /7 PIS I O (EXAMI'IF: ITEM A -I) C6� FIRE LINE TO BUILDING SHALL BE PROVIDED &INSTALLED BY FIRE SPRINKLER H / - . DOMESTIC WATER FIXTURE UNITS - 659 CONTRACTOR CONFORMING TO ALL LOCAL, STATE, AND NATIONAL CODES ROOM NUMBER SYMBOL WASTE FIXTURE UNITS - 422 (EXAMPLE: ROOM #100) EST. PEAK DISCHARGE - 165 GPM EST. PEAK FLOW - 165 GPM INCLUDING NFPA 13. / RT MECHANICAL EQUIPMENT SYMBOL EST. AWE. DAILY DISCHARGE - 17,000 GPO + 100 GPM IRRIGATION ,� FUEL FARM ; / GOT57 e (EXAMPLE: ROOFTOP UNIT #D EST. MAX. DAILY DISCHARGE - 26,000 GPD EST. AVERAGE DAILY FLOW - 17.000 GPD CJ RISE UP COLUMN TO 8'-0" AFG WITH 1/2" AIR LINE TO AIR REEL. PROVIDE BALL q PLIR 1BIN6 EQUIPMENT (*UPC FIXTUE UNITS) EST. MAXIMUM DAILY FLOW - 26,000 GPD SHUT-OFF VALVE AT AIR REEL. SEE EQ SHEETS FOR MORE DETAILS. SOFT WATER DEMAND: (EXAMPLE: FIXTURE E 01) I)L EST. PEAK FLOW - 75 GPM; 5 GPH; 15,000 GPD / ; 7 roNNEGT TO 517E REFERENCE SYMBOL LEGEND 55 AT MANHOLE GENERAL NOTES TO ALL SHEETS e . NORTH _ UNIT GAS LOAD SUMMARY LOAD WATER HEATER - - - - - - - - - - - - - - - 500 CFH O CONFIRM THE EXACT LOCATION OF ALL EQUIPMENT PRIOR TO WATER HEATER - - - - - - - - - - - - - -- 500 CFH MAKING PLUMBING ROUGH -IN. PROPANE ` ; PARTIAL SITE PLAN— GREASE INTERCEPTOR LOCATION ' s20�o' P31 WATER HEATER - -- - - - - - - - - - - - - - 500 CFH • � ALL- WATER AND DRAIN LINES OUTSIDE OF THE BUILDING STRUCTURE / DRYER P17 STACKED - - - - - - - - - - - - -105 CFH SHALL BE A MINIMUM, OF THIRTY-SIX INCHES BELOW AVERAGE ANNUAL DRYER P17 STACKED - - - - - - - - - - - - -105 CFH FROST UNE REFERENCED TO FINISHED GRADE (MINIMUM DEPTH 60" WHERE /(�� DRYER P17 STACKED - - - - - - - - - - - - -105 CFH AVERAGE ANNUAL FROST LINE IS LESS THAN 30".) �J Ob AN 1 `� 5 2' 6 I' 9 �(TyP) DRYER P17 STACKED - - - - - - - - - - - - -105 CFH GW- - - - - _- - - - - - - - _�- ROOFTOP UNIT RT-1 - - - - - - - - - - - - - -250 CFH O3 CONFIRM THE EXACT LOCATION WHERE SEWER, WATER AND F -- _ ROOFTOP UNIT RT-2 - - - - - - - - - - - - - -250 CFH GAS LINES LEAVE THE BUILDING. F - - - - J- - - - - - • -- GA- - ---- - -GA-- � �� -- - GA - - -- --- � _ ROOFTOP UNIT RT-3 - - - - - - - - - - - - - - 350 CFH - OO } -- �t' \�� i _- _:-. r-� t-==-- f --� ROOFTOP UNIT RT 4 - - - - - - - - - - - - -250 CFH O4 THE PLUMBING CONTRACTOR SHALL INSTALL WATER PIPING -!� - ROOFTOP UNIT RT-5 - - - - - - - - - - - - -350 CFH ABOVE THE CEILING SUCH THAT THE PIPING WILL BE BETWEEN - L I ROOFTOP UNIT RT-6- - - - - - - - - - - - - -350 CFH THE BUILDING INSULATION AND THE CEILING TO PREVENT R.V. L ❑ I f I I ROOFTOP UNIT RT-7- - - - - - - - - - - -135 CFH FREEZING. SEE DETAILS AND SPECIFICATIONS. ISLANDS l I it - I ROOFTOP UNIT RT-8- - - - - - - - - - - - - -250 CFH - 11 k-&4 I 1 f, - I I TRASH AREA DRAIN MAKE-UP AIR UNIT MU-1 - - - - - - - - - - -600 CFH O THE TERM "ROUGH-IN"INCLUDES AT PROPOSED FIXTURE LOCATIONS 4, I G - I I I 5 2' J.R SMITH NO. 2233 MAKE-UP AIR UNIT MU-2- - - - - - - - - - - -600 CFH 1) SHUTOFF VALVES OR STOPS AT HOT AND COLD WATER STUB rj- - - y�-,�- - -� - I• I CONNECT TO STORM DRAIN SYSTEM MAKE-UP AIR UNIT MU-3- - - - - - - - - - - -600 CFH ID 3/4 I I/2 f I J MAKE-UP AIR UNIT MU-4- - - - - - - - - - - -250 CFH OUTS. _ 1�3 KITCHEN LOAD - - - - - - - - - - - - - - - 1110 CFH 2) VENT PIPE THRU ROOF OR CONNECTED TO VENT SYSTEM, /48 LXA T-5TAT I I I 1 I , LABEL 3) DRAIN LINE, TRAPPED AND VENTED, STUBBED THRU WALL, "� HA - - - - - - -7265 CFH OR FLOOR, AND CAPPED. E IT C RV �I q I I 16� O. MY" TOTAL O6 ANY PENETRATIONS THRU OR TRENCHES IN CONCRETE FLOORS PUMP I 1 i1 1 L I ; -h:II TOTAL DEVELOPED LENGTH- - - - - - - - - - - - -120 tt. I- OR PARTITIONS SHALL BE SAW CUT OR CORE DRILLED. Q 2 PSI GAS REQUIRED DOWNSTREAM OF METER 8� i ; I i b 1 IRRI6AnoN SYSTEM CURB STOP O7 ANY PENETRATIONS THRU FIRE RATED PARTITIONS SHALL BE I d WASTE GAP FOR FUTURE CONNECTION GAS PRESSURE REGULATOR SCHEDULE SEALED WITH SCOTCH-3101 (FS195 WRAP AND /CP25 CAULK - 13Y LANDSCAPE CONTRACTOR AS PER MANUFACTURER'S RECOMMENDATIONS. 1-.. S.�@� LQAQ REGULATOR DESCRIPTION P21 1 ( I I SEE DETAIL IO/P-DI. I ` GPR y1 1500 CFH FISHER 5202, 2" BODY, �" DIA. PORT GPR /2 1110 CFH FISHER S202, 2' BODY, }�" DIA. PORT GPR 13 1585 CFH FISHER S202, lh- BODY, Y8' DIA. PORT F it I GPR 14 3075 CFH FISHER S202, 2' BODY, Y4 DIA. PORT D 4' TOTAL 7265 CFH SHEET P-1: PLUMBING 51TE PLAN �, �� i i TRAVEL PLAZA ; 4' I UTILITY LOAD SUMMARY "° RI_vlsloNs/sueM15510Ns DateNN SHEET P-2: PLUMBING FLOOR PLAN I I I I r /4• WATER- FT. PIERCE UTILITIES AUTHORITY GAS - FT, PIERCE UTILITIES AUTHORITY If SHEET P-3: PARTIAL PLAN 5HOWER5 AREA, PLUMBING I DIVE RT JOHN RUSSEN 206 SOUTHOUTH 6TH 5T. 206 SOUTH 6TH ST. I J I- -IIW- i FT. PIERCE, FL 34950 FT. PIERCE, FL 34950 SHEET P-4: PARTIAL PLAN KITCHEN I 9 70 - / ' I C0MMECT DRAIN FROM CAN WASH (561)466-1600 EXT. 3423 (561)466-1600 EXT. 3307 G f �_�,� TO STORM DRAIN 5Y5TEM IN TH15 FIRE PREVENTION - ST. LUCIE CO. FIRE DISTRICT t PLUMBING GAS 1 ) ` AREA. CONFIRM EXALT LOCATION. JOHN HAYDEN (561)462-2312 ISLANDS �® ®O I L I 6 2400 RHODE ISLAND AVE., FT PIERCE, FL 34950 5HEET P-5: PARTIAL PLAN KITCHEN I I ib a design build company ROUGH -IN I t L F T6 UTILITY CONTACTS _ - 60 WEBT 890 SOUTH, BPoOHAM CITY, IJTAH 84302 1801D 794-8607 — 5HEET P-b: PLUMBING SCHEMATICS I I ` J S NAME ei HB3 1 1 FLY I NC .1 TRAVEL LODC E _ _ , L 12 I I FLORIDA • SHEET P-'I: PLUMBING SCHEDULES � _��� _ 1 1 120 North Twelfth Avenue SAINT LUCIE, B d DETAIL5 F �' 14 1 I " — Pocatello, Idaho 53201 ----- - - - B �® -- ®0 I PHONE (208) 232-25-n MRAHIN6 TITLE SHEET P-8: PLUMBING ROOF PLAN r� 11 Nielson Engineering, Inc.. FAX (208) 234-0918 PLUMBING 517E PLAN SHEET P-DI: PLUMBING DETAILS ( :, 2Y-,� \3y Consulting Engineers SEAL- DFFA1•W GDH F'ROJEGTNO. gb515 ' SHEET P-D2: PLUNGING DETAILS I I ! �. ONPER5HIP OF DOCUMENTS c t5c<w °SERIES L_14 200 SHEET P-D3: PLUMBING DETAILS 1 1 This document and the ideas and designs incorporated herein, as an instrument of GDH j I professional service, is the property of NIEL50N ENGINEERING, INC. and Is not to be used, REVIEKV ORAHIN6 NO. A A I L I 1 1 NORTH in whole or in port,for any other roject without the written authorization of an authorized p 1 ; representative of NIEL50N ENOINEERIN6,INC. j ! ) << ATE _ � GONT. 31P-I. � ,j Unauthorized use will be prosecuted to the fullest extent of the Law. r ._ - - - - - - - - ._ _ - _ - - = JAWARY Iggb DRAWING SCHEDULE L_� --� PLUMBING SITE PLAN i S2o o PCALE ' �P,it ©I}}� by: NIELSON EN6INEERIN6, INC. i SGALEI =20-0 1 .-. -- ° r n n .1 of I 2 3 1 4 5 b l 8 G 10 I I 12 13 14 t' I I 2 3 I 4 I 5 I 6 I l I 8 I 9 f 10 I II 12 FOR PIPINCs IN THIS AREA SEE 5NEET. P-3 04 --t - -_ - --- -__- -� FOR PIPINCs IN THIS AREA SEE SHEETS P4 4 P-5 PLUMBING VALVE BANCdET ZONE "4 O (D L • B I - t� - _ Ii _s l �_ _ �_ -� --® OO 4II i II 4O D, CD O OTCS —C ,OTG R0 3 3 J K LEGT. I II FL �eING VALVE III II III —IMAINTENANCE 2GJ ®DISH. ZONE tSTORACE MECH. z G o o © ® COFFEE ® ChSTORAGE °II'15MVALVE COI3NBTE R � Ib ACCE MEZZANINE C- HALL R ABOVE P YA ELECT. --- P UMBINCs — - - -- - - — ZONE 02 O I I I(25m ) I HALL © HALL �� ®� �® o (350 CR1) — — — — — — 14 G - 2 Il2Ys 9 I �.T a4 . ,, GI�1 I , ® I ® - l I I 21G G Z,=,GOF�ICE � G —a. - --J I I ACCOUNTING BREAK I 2� 3 ,, ?�, G7N n] 4$ H I I I I I I © 2Ys ----- WAITRESS ® BUFFET ® I FM---- —__ - STATION lFIMAREA 7376 oar ® I 9 600 cFH) PREP I . G GPR�3 \ 15 e PLNEB10 V�ALyE 6 Ci4UT FREEZER KITCHEN ZONE �0 Ib 1 ®�� ® I © o LGOOK CIPH) INE oo IRESTAURANT 1 ST® III (�O o I 135 HALL - -- I V� ILISTORAGEP UMBIW VA COOLER®� IYs -I I �. ZON 16 I ® (250 CFH) (315 CRO _ i- I� \\\\^ I � 14z'G I/1 E --- PLUMBINCsyaLVE I LAUNDRY ( __ _ — - -- —_— —_—------------ - 9 ZONE Ib ® 12 -- - _- t I WALK-IN � — --� FAST F0 VE .14 WALK-IN COOLER COOLER ® z 34'6 �I'4G - C DRIVERS IO6 ® 114Ys I a FREEZER 1135 GFH) 9 I -FM -- -- 1250 CFH/ OFFICE FF62 �----------- z.W.------- (350a44) 11----PLUMBINCs VALVE . ZONE MI �J MAGIC 0 -- :. \ ... , ,. � DRAGON 4 O I� FAST FOOD STAURANT I - - ' \ 1 � SEATING CASHIER 38B FT3TD I (3 E GAME I BARBER q L CONVENIENCE STOREROOWAITING 06 I 3 C) ® I I 0I -- _ _ - i5 ®j44 G AREA Ii4'G (250 CF+1) 39 ----- -_ PLUMBIC VALVE L — _ _ �J I ® G — ® 4 11 HALL ZONE �6 / w I (350 CFI) :. O 1)EATING AREA b. 1' i5 �— AI. • HALL ® PLUMS LYE MEWS FOR PIPINCs IN ZONE �V2 ('�) THIS AREA SEE WOMEi I NSFIWJ IN ® I i THIS AFOR IREA SEE - —�_— SHEET P-3 SHEET P-1 G - I I I � I I I 2 B PLUMBINCs VALVE ZONE SUMMARY VALVE ZONE GCNTROL AREA Fl 6HOWER5 > R REST ROOMS 04 LAINDRY/51-10LllER6 5 PUBLIC LAUNDRY/5610WER5 % BARBER 51a0P "T MAINTENANCEMIECHANICAL (W '8 BREAK AREA 9 KITCHEN 0I5WIASW W KITCHEN hl FAST FOOD 92 PUBLIC RE5TR0015/C-5TORE_ I 2 3 12 CASHIER AREA FUAI �� II _ I El I 3 V C%. SCALE I/8'=1T'-0' 1 I M 3 O L] —J — 4 5 9 1 10 I --J VEST. IW it F— — -- __1 13 14 ABBREVIATION SCHEDULE KEY NOTES TO SHEET P-2 SYMBOL OCONTINUED PLUMBING SITE PLAN 1/P-1. DESCRIPTION A/C AIR CONDITIONING O CONTINUED PARTIAL PLAN PUBLIC REST ROOM PLUMBING SHEET P-7. M ASR AUTOMATIC SPRINKLER RISER AVG AVERAGE O CONTINUED PARTIAL PLAN KITCHEN PLUMBING SHEET P-4. AFF AVERAGE FINISED FLOOR BFF O CONTINUED PARTIAL PLAN 6ARBERSHOP PLUMBING SHEET P-3. BELOW FINISHED FLOOR BFP BACKFLOW PREVENTER BTU BRITISH THERMAL UNITS O AUTOMATIC DRY PIPE SPRINKLER RISER ASSEMBLY W/EXTERIOR- GONG; INTERIOR - CATCH BASIN CB ALARM (CONFIRM EXACT LOCATION INAOCAL AUTHORITY), ALARM VALVE, CFH CUBIC FEET PER HOUR CHECK VALVE, ETC. REFER TO FIRE SPRINKLER SHOP DRAWINGS FOR CL CENTERLINE LAYOUT. (SEE DETAIL I/FS-I). PROVIDE & INSTALL IN FIRE CO CLEANOUT RISER A SUPERVISORY ELECTRIC VALVE TAMPER SNATCH AND FLOW CONC CON T CONCRETE CONTINUED - INDICATOR. THESE SHALL REPORT NA TELEPHONE LINES TO CITY L CONTR CONTRACTOR APPROVED MONITORING SERVICE COTG CLEANOUT TO GRADE O GAS METER PER GAS COMPANY. DOWN DN DS DOWNSPOUT 7 2" COLD WATER AND t' COMPRESSED AIR LINES FOR OUTSIDE SERVICE ELECTRICAL CONTRACTOR EC ISLANDS. ELEV ELEVATION O DROP WITH ROOF AND OVERFLOW DRAINS RAIN WATER PIPING AND EXIST EXLSTING DISCHARGE ONiO PAVEMENT AT 6" AEG. SEE DETAIL 13/P-D1. FLOOR CLEANOUT FCO Ug DROP THRU CEILING NTH GAS LINE TO GAS APPLIANCES BELOW. FD FLOOR DRAIN (CONFIRM EXACT LOCATION) FE FIRE EXTINGUISHER K FEC FE & CABINET ip LOCATION OF FIRE SPRINKLER SYSTEM SIAMESE FIRE DEPARTMENT FHB FLOOR HOSE BOX CONNECTION. FHC FIRE HOSE AND CABINET FL FLOOR 11 REFER TO FIRE SPRINKLER CONTRACTOR SHOP DRAWINGS & SHEET FS-1 FOR FPS FEET PER SECOND CONTINUATION. (SEE SPECS.). FS FT.HD FLOOR SINK FEET OF HEAD 12 CONTINUED PARTIAL PLANS SHOWERS AREA PLUMBING SHEET P-3. FTR FLUE THRU ROOF 13 NOTE NOT USED FU FIXTURE UNIT 14 RISE WITH 2 1/2" MEDIUM PRESSURE (2 PSI) GAS LINE OUTSIDE BUILDING THRU G NATURAL GAS WALL AT APPROX. 24' AND RISE TO TRUSSES. PROVIDE AND INSTALL A GC GPM GENERAL CONTRACTOR SHUTOFF VALVE IN THE VERTICAL RISER OUTSIDE THE J GR GALLONS PER MINUTE GRADE BUILDING. SEE DETAIL 11/P-D3. HB 15 RISE WITH GAS LINE INDICATED TO ROOF. CONTINUED PLUMBING ROOF HOSE BIBS HD HUB DRAIN PLAN SHEET P-8. HTR HEATER 16 PLUMBING VALVE ZONE. SEE SHEETS P-3, P-4 & P-7 FOR ZONE BALL VALVE INVERT ELEVATION IE LOCATIONS. COORDINATE WITH ARCHITECT. SEE DETAIL 5/P-D3. IW INDIRECT WASTE 17 6" PVC BEVERAGE CONDUIT EXTENDED 4" THRU FLOOR AT BOTH ENDS LP LIQUID PROPANE & TEMPORARY CAP. INSTALL WITH PULL CORD, SEE DETAIL 2/P-D3. e MAXIMUM THOUSAND BTU'S PER HOUR MAX MSH 18 GAS PRESSURE REGULATING VALVE TO REGULATE GAS PRESSURE FROM 2 PSI H MC MECHANICAL CONTRACTOR TO 8" WC. VENT THRU ROOF SIMILAR TO SANITARY VTR. SEE DETAIL 18/P-02. MECH MECHANICAL i MH MANHOLE MIN MINIMUM NIC NOT IN CONTRACT OD OVERFLOW DRAIN 1. DOMESTIC WATER: TYPE 'K' SOFT COPPER BELOW FLOOR OR PC PLUMBING CONTRACTOR GRADE. TYPE. V HARD DRAWN COPPER PIV POST INDICATOR VALVE TUBING w/ WROUGHT COPPER SOLDER JOINT POC PSI POINT OF CONNECTION POUNDS PER SQUARE INCH FITTINGS ABOVE FLOOR OR GRADE. PSIL PSI LOSS BELOW GRADE: 3/4" - 2 1/2" TYPE "K" SOFT COPPER 3" + DUCTILE IRON OR RD ROOF DRAIN PVC CONFORMING TO AWWA STANDARDS REG REO'D REGULATOR REWIRED 2. WASTE & VENT, SERVICE WEIGHT=NO-HUB CAST IRON w/ RI & C ROUGH -IN AND CONNECT RAIN WATER 'MG' OR 'IDEAL' FITTINGS. SCHEDULE 40 GALV. STEEL FOR EXPOSED VENT LINES. STA STATION (ABS/PVC PIPING CONFORMING TO IAPMO AND VEL ASTM SPECIFICATIONS WILL BE ACCEPTABLE VELOCITY VTR VENT THRU ROOF WHERE PERMITTED BY LOCAL CODES. ALL DRAINS & TRAPS TO BE CAST BRASS, w/ WITH CAST IRON OR GALV, STEEL. WCO WF WALL CLEANOUT WALL FAUCET 3. GAS: SCHEDULE 40 BLACK STEEL w/ BLACK F WTR WATER MALLEABLE IRON SCREWED FITTINGS. 4. CONDENSATE DRAINS: TYPE V HARD DRAWN COPPER w/ WROUGHT COPPER SOLDER JOINT FITTINGS. SCH. 40 PVC FOR WALK-IN COOLER/FREEZER DRAINS 5. AIR: GALV. SCHEDULE 40 STEEL w/ GALV STEEL SCREWED FITTINGS ABOVE FLOOR OR GRADE TYPE V HARD DRAWN COPPER w/ WROUGHT COPPER SILFOS JOINT FITTINGS ABOVE FLOOR OR GRADE. NO GALVANIZED PIPE BELOW GRADE. E ALL UNDERGROUND PIPING SHALL BE INSULATED W/IMCOA INSULATION. PIPE 5PECIFICATION5 No. I REVI510N$/5U5MISSI0NS I Data Fol C, a design build company 50 WEST 990 SOUTH, BRIGHAM CITY, UTAH 84302 (801) 734-6507 JOBNAP'IE FLYING J TRAVEL PLAZA — 120 North Twelfth Avenue SANT LUCIE, FLORIDA Pocatello, Idaho 03201 B Nie sore En ineeri�l , Inc.PHONE (208) 232-2511 DUNG TITLE g g FAX (208) 234-0918 PLUM51% Gcrosultfng Engineers FLOOR PLAN - SEAL DRAUNI PROJECT NO. cDH 96515 OWNERSHIP OF DOCUMENTS CHECKED SERIES This document and the ideas and designs incorporated hmen ereln, as an instrument of CDH L-15-200 ofessional service, is the property of NIEL50N ENGINEERING, ING. and 15 not to be used, REVIEWED DRAWING NO. A whole or 'in part,for ar other project without the written authorization of on authorized cow representative of NIEL50N ENGINEERING, INC. DATE Unauthorized use will be prosecuted to the Fullest extent of the Law. JANUARY 1998 Goff ight © Iggg by: NIEL50N ENGINEERING, IW_ SCALE 2 of it 12 13 14 1 M K J G Ii E. I n 2 I 3 I 4 I 5 6 l g g 10 II 12 I 13 I 14 PLVALVES FOR ZONE M O PLUMBIWz VALVES FOR ZONE •4 O PI �k ® o Pl "PI ® 1 /�\ O 8 3/4Ys 13 13 W H Q h P5 114 PIb 2' ¢ 2 11/4' I ' O --- 3/4'-_ P� I - 3/4• - - C. - - 3/4' — 4 13 3/� -- - I _ 1 13 2V7' PI _ I - -- -- -- _ w1Io -- ., 1�11f/ U 1 PI 3/4 11/41 3/4' - 1 3/4' 1 CFSI) PLUMSIW3 VALVES FOR ZONE 02 �I I P5 13 PI I O �2, _ 2 I I O 1 ; 13 PLUM W4 VALVES O ® I FOR ZONE I0 i 1Vt' 1 1 4. 2' p1 _ -2 - 1� � I 2Vi' 1 IV3 13 I a® P6 1 /3/4' 3/4 , O - P6 - L- z - 2 ® Q 111 nl 03 O U 3/a' IYa - - - - Pll M1 PARTIAL PLAN SHOWER AREA WATER �' SCALE 114' = 1'-0' 3/4' /4' ® M1 1 i PLUMBIW4 VALVES C j FOR ZONE '6 i 2 3 4 5 6 8 1 Co L Q - Q I 13 r I. • e � I SI II y •I� KEY nAN NO SCALE i 3 KEY NOTES TO SHEET P-3 z OCONTINUED PARTIAL PLAN PLUMBING FLOOR PLAN SHEET P-2. M OCONTINUED PARTIAL PLAN KITCHEN PLUMBING SHEET P-4. U3 MOUNT THIS FIXTURE AT 17' AFF TO LIP TO MEET HANDICAP CODES. PROVIDE & INSTALL WOODFORD MODEL 24 HOSE BIRD WITH METAL WHEEL HANDLE AT S-6- AFF (HW & CW) FOR JANITOR CLEANING SYSTEM. MOUNT SERVICE SINK FAUCET AT 24" AFF. PROVIDE & INSTALLL WATTS NO, L7.DOUBLE CHECK VALVE IN EACH HW & CW LINE TO SERRVICE SINK. 0�5 DROP BELOW FLOOR WITH WASTE LINE. �J CONTINUED PARTIAL PLAN SHOWERS AREA WATER. L 0 CONTINUED PARTIAL PLAN BARBER SHOP THIS SHEET. 0 DROP THRU CEILING WITH GAS LINE THRU COCK TO GAS APPLIANCE INDICATED. O9 WASHER VALVE BOX TO BE INSTALLED 0 37h7 CENTERLINE FROM FINISHED FLOOR. O PLUMBING ZONE BALL VALVES FOR INDICATED ZONE EXPOSED AT CEILING. SEE DETAIL 5/P-D3. SEE SHEET P-2 FOR ZONE LOCATIONS. 11 NOT USED I K ODROP FROM ROOF MATH COPPER CONDENSATE DRAIN LINE. DROP IN WALL TO LAVATORY & CONNECT TO LAVATORY TAILPIECE 13 PROVIDE & INSTALL WATER HAMMER ARRESTOR AS REQUIRED TO PREVENT WATER HAMMER. SEE DETALJ. 10/P-D1. 1 f-11 d L--- - O 3/4' 34' - 3'UlCO 1 T- I PI9 I I p I 3{./ 4, 14 I u PIS ul G PARTIAL PLAN BARBER SHOP Iill 0' F Am 120 North Twelfth Avenue _ 'mm- � Pocatello, Idaho 63201 Nielson Engineering Inc. PHONE 8)234206) 0910 1 FAX (208) 234-0918 C.onsuiting Engineers OUNERSHIP OF DOC11ENTS (� This document and the ideas and designs Incorporated herein, as an Instrument of professional service, is the property of NIEL50N EN6INEERIN6, INC. and Is not to be used, E in whole or in port,for any other project without the written authorization of on authorized representative of NIEL50N EN6INEERIN6, INC. Lhouthorized use will be prosecuted to the fullest extent of the Low. Copyright ©1498 by: NIEL50N EN6INEERIN6, ING. II 12. 13 14 g 10 No. f�V1510NS/SUBFt1551ONE, I Ddte D C a design build company 50 WEST 990 SOUTH, BFUGHAM CITY, UTAH 84302 f801 734-6507 JOB NAME FLYING J TRAVEL PLAZA SAINT LUCIE, FLORIDA DRAWNG TITLE T PARTIAL PLANS SHOWERS AREA PLUMBING SEAL DRAUN PROJECT NO. 96515 GDN CHECKED SERIES L_15-200 GDN _ REVIEWED DRAWING NO. A GDH � P DATE JANUARY M% eCAL.E 3 of 11 I/a'=r-m' 1 2 3 DROP BELOW FLOOR WITH CW 4 EXTEND TO 5' BEYOND BUILDI% PERhETER ROOF 4 OVERFLOW INSTALL STOP 4 WASTE FOR CONNECTION DRAIN DOWN SPOUTS BY LANDSCAPE CONTRACTOR SEE M � DETAIL 10/P-DI. ALARM GGNCi FIRE DEPARTMENT CONNECTION a CA L 21 PIPE SPRINKLER VALVE GOMBUSTIIO AIR D MECH.SHTS • -CONTIRED FIRE CONNTRNIIACTOR FD3 SHOP DRAWING6 �--� MAINTENANCE t STORAGE 4131 2-VA 1 MEZZANINE ABOVE 1 HALL jL�._1 ----------------- --- 1 - ' I.] 91 HALL Ind] 2V2 - 200 CF14 V3 50 CFH 1 80 CFH 2Ys 62 CFH 80 CFH 80 CFH 60 CFH 131 CFH 122 CFH 122 CFH 10 CFH 2Ys 50 CFH 2 Ys 122 CFH GAS PIPING SCHEMATIC NO SCALE 2 3 4 I 5 I (0 PIPING IN MECHANICAL ROOM IS 01 `T' r)Idf.;IAMATir RIN PIPINr, M TWF I 1 8 9 10 11 12 13 14 I I I I I - - - --- /CAN WASH STATION. ./ 5EE DETAIL II!) (_1 01/ = 4' Div ! 3' �3'V 4' II SCI f L--- -- -----•�!Tv 3'1ITR 3 \I 2, I -I F51 FD2 O 1 I °1--2 STORAGE ❑u] 1"I L - C 62 ( I h3o. 23 yz, WALK-IN COOLER 9 4' -�� 1 FCO 25 FSI FREEZER 1 1018 j I - --- ---- ---- — _ -_-_ _ _ _ _ _ —— — — — PEPPERONI'S �Yv I I � LARGE 5CAL-E KITCHEN PLUMBING PLAN T �_ —_ ACCESS SCALE 114'=1'-0' II � COVER 24' 1- - J 1 L - BALL MT- - _ u OFF VALVE (TYP) PLUMBING ZONE VALVE Sox NO SCALE 4 5 6 1 8 F52 l I FCO �y I I I L b 2 3, I' DISH. p I -- I - COFFEE COUNTER 1 131E -0 F51 KEY NOTES O CONTINUED PLUMBING FLOOR PLAN SHEET P-2. M ODROP BELOW FLOOR WITH COLD WATER AND HOT WATER & RUN UNDERFLOOR TO FIXTURES INDICATED. SEE DETAILS 4 & 5/P-DI.INSULATE RISE WITH VENT WITH 1/2' IMOCOA INSULATION, NO JOINTS UNDERFLOOR. IN COLUMN / 3� 6" PVC BEVERAGE CONDUIT EXTENDED 4' THRU FLOOR AT BOTH ENDS & - - - -- - - - - - 1� TEMPORARY CAP. INSTALL NTH PULL CORD. SEE DETAIL 2/P-D3. COORDINATE _��- 21V - ROUTING WITH FOOTINGS. 2 FS (_ GAS LINE FROM ABOVE. RUN THRU OWNER PROVIDED P.C. INSTALLED AUTO SHUT- bT�' OFF ELECTRIC SOLENOID (N.C.) GAS VALVE. DROP CONCEALED IN WALL, TEE & MANIFOLD ON EACH SIDE OF HOOD WALL. SEE DETAIL 16/P-D2. ? I INDIRECT WASTE LINES FOR WALK-INS SHALL BE PITCHED 1/3'/FT. L 1 s4 l bJ PROVIDE AND INSTALL HEAT TAPE ON ALL DRAIN LINES IN WALK-IN FREEZER. - - - GW HEAT TAPE TO BE SUCH AS RAYCHEM AT-180-8XL TAPE. INSULATE ALL DRAIN -Hw - �4, J LINES INSIDE FREEZER COMPARTMENT WITN h" ARMAFLEX INSULATION. Oj PROVIDE PRESSURE REDUCING &/OR REGULATING VALVES FOR DISHWASHER, BOOSTER HEATER AND AS REQUIRED BY KITCHEN EQUIPMENT CONTRACTOR, ROUGH -IN FOR FUTURE DISPOSER. ODO NOT RUN WASTE FROM THIS FIXTURE THRU GREASE INTERCEPTOR. (:S) MAKE CONNECTION TO COOLING COIL CONDENSATE DRAIN PAN & RUN TO FLOOR SINK. SEE DETAIL 13/P-D2. K 100 DROP TO 6" ABOVE COOLER FLOOR AND THRU WALL TO FLOORSINK. SEAL PENETRATION. SEE DETAIL 13/fs-D2. 10, E PROVIDE & INSTALL WOODFORD MODEL 24 HOSE'BIBB WITH METAL WHEEL HANDLE AT S-6" AFF (HW & CW) FOR JANITOR CLEANING SYSTEM. MOUNT SERVICE SINK FAUCET AT 24' AFF. PROVIDE & INSTALLL WATTS NO. 6 CHECK VALVE IN EACH HW & CW LINE TO SERRMCE SINK. SEE SHEET P-5 FOR EXACT PLACEMENT OF FLOOR SINKS & OTHER ROUGH -IN REQUIREMENTS. 13 PLUMBING ZONE BALL VALVES FOR INDICATED ZONE EXPOSED AT CEILING. SEE DETAIL 5/P-03. SEE SHEET P-2 FOR ZONE LOCATIONS. J 14 1 1/4" ROOFTOP UNIT CONDENSATE DRAIN LINE FORM ABOVE. DROP IN WALL TO 6" AFF, PENETRATE WALL, TURN 90' DOWN AND DISCHARGE IW INTO - ------------, RECEPTOR SHOWN. CONFIRM EXACT LOCATION. SEE DETAIL 17/P-D2. — 2' - --I-J BUILDING MAIN DOMESTIC WATER SHUT-OFF VALVE, PRESSURE REGULATOR 3, VALVE &DOUBLE CHECK BACKFLOW PREVENTER ASSEMBLY. SEE DETAIL 3/P-Dt. 2' PLUMBING ZONE VALVES O CONTINUED PARTIAL PLANS SHOWERS AREA SHEET P-3. ZONE No. 9 (�J IT ENCASE 4" DOMESTIC WATER LINE BELOW FLOOR IN 6" PVC PIPE FROM 4" �34V 24 ABOVE FINISHED FLOOR TO 5' FROM BUILDING PERIMETER. SLOPE PIPING �I _ TOWARD OUTSIDE OF BUILDING. , L T 1 O RISE TO CEILING WITH 4' WATER LINE. RUN AT CEILING. Frjlrr ) COMBINATION WASTE & VENT SYSTEM SEE DETAIL 14/P-D3 1 8 O �y�� 20 PLUMBING ZONE BALL VALVES FOR INDICATED ZONE IN WALL BEHIND J.R. p 12-V I SMITH No. 4760 LOCKING ACCESS COVER (18x24). SEE SHEET P-2 FOR FSI 1ZONE LOCATIONS. SEE DETAIL THIS SHEET. WAITRESS __ STATION1 8Oo18 2 21 RUN COMPRESSED AIR LINE TO DRY PIPE FIRE SPRINKLER VALVE TO INSTALL 2'V 2'v 2I I 2 24 BALL SHUT OFF VALVE & UNION. FIRE SPRINKLER CONTRACTOR SHALL MAKE \ I I E CONNECTION TO SPRINKLER VALVE. SEE DETAIL 1/FS-3. \2' 2' FSI I 25 3'p 22 DROP DOWN WALL THRU BACKFLOW PREVENTER WITH WATER & COMPRESSED AIR \ \ I 25 & RUN TO ISLAND HOSE & AIR OUTLETS. SEE DETAIL 6/P-DI. 1-__- \\\� I V;z 3v ( may' 23 GAS APPLIANCE CONNECTION. SEE SHEET P-5 FOR ROUGH -IN REQUIREMENTS. 1 7 1/2'_ _ �3'V _ _ _ _ _ _ _ 43'V- C_I _ I 1- - - - - _ MAKE CONNECTION THRU SHUT-OFF VALVE. CW4V � I 1=Gw4V 24 SUPPLY & INSTALL HOSE BIBB ON WATER LINE. (WOODFORD MODEL No. 24P 'V 24 O ®1 FCA I WITH TEE KEY HANDLE, POLISHED CHROME & VACUUM BREAKER) 2, I FSI q I SUPPLY & INSTALL BALL SHUT OFF VALVES ON ALL BUFFET & FAST FOOD PAN BIDET I I 25 2 DRAINS. CONFIRM EXACT LOCATIONS & NUMBE WITH KITCHEN EQUIPMENT CONTR. IFD2 2' \ \ FD2 AREA I I — F j 2'Fr3TC —I 25P00 I I - ; ,� -CW- - - - - - J 120 North Twelfth Avenue F51 2 I 'v 1 Pocatello, Idaho 83201 \ \\ - O ; RESTAURANT PHONE (206) 232 -2511 cools \\ I i Nielson Engineering, Ir FAX (208) 234-0916 1-L 11 \ \ I O F51 O (n P) � 2 Gonsulting Engheers �2v F51 • _ - !'_cw- - -- - ; - OIWERSNIP OF DOCUMENTS - -- -Hw- — �i' O This document and the Ideas and desq)5 Incorporated herein, a6 an Instrument of ILL -n professional service, Is the property of NIEL50N EWNNEtrRINI INC. and Is not to be used, E 4 �JO i 2 25 �j In whole or in partlor arty other project without the written authorization of an authorized �J representat ve of NIEL50N ENGINEERING, INC. 3 1 Unwthorized use will be prosecuted to the fullest extent of the Law. P2 4 CONTRACTOR SHALL MAKE GoNrL3ht ©1998 by: NIEL50N ENGINEERING, INC. _ FSI 1 r 2'V I • II , I PLUMBING ZONE VALVES 4' ZONE No. 10 20 I , FAST FOOD VENDORS 1 FCO. I 2 3' I FSI C 1 I � 2FS R,90FD2 , 2I I MAGIC DRAGON RISE TO b' AFF. MIN ` .17*V WITH VENT& BEFORE \ OF&ETTNG. RUN VENT IN MILLWOI (TYP.) RESTAURANT i CASHIER 2 ' atp ALLOWANCE FOR UNDER FLOOR VENT R15E IN THIS AREA VENT 544ALL SLOPE THE SAME AS THE DRAIN BUT IN TI$ OPP061TE DIRECTION. -- — -E I 1 I! D 9 10 11 12 1 13 I 14 No. I REVISIONS/SUBMISSIONS 1 Date C a design build company 50 WEST 990 SOUTH, BFUGHAM CITY,. UTAH 84302 (801) 734-6607 - JOB NAME FLY NG J TRAVEL PLAZA SAINT LUCIE, FLORIDA DRAWINCs TITLE PARTIAL PLAN KITCHEN P_ LUMBIWj SEAL DRALLN cDH }'ROJECT NO. 96515 CHECKED SERIES cDH L-15-200 R.EVIEWED DRAUWI NO. A CDH DATE — JANUARY 1598 eGALE 4 of 11 1 2 3 4 5 6 1 8 9 l0 it 12 13 14 PLUMBING ROUGH- IN SCHEDULE GENERAL NOTES TO SHEET P-5 ROUGH IN CONNECTION REMARKS 1 ALL REFRIGERANT PIPING TO BE PROVIDED AND INSTALLED BY M RI TYPE SIZEH T # DESCRIPTION SIZE H T ITEM REMARKS O REFRIGERATION CONTRACTOR. ALL REFRIGERATION LINES SHALL KI DIREGT DRAIN IF +12" HAND SINK IF +18" #113 VERIFY W/ SUPPLIER BE INSULATED WITH 1/2- ARMAFLEX INSULATION. M K2 H4C WATER fit" +12" HAW SINK +30" #113 VERIFY H/ 9JPPLIER O SEE SHEET P-4 FOR PIPING ROUTING AND SIZING. K3 DIRECT DRAIN i +12" HAND SINK i +12" #113 VERIFY H/ SUPPLIER O3 SEE KITCHEN EQUIPMENT DRAWINGS FOR EXACT EQUIPMENT K4 H4G WATER +12" HAND 51NK +30" #113 VERIFIMU SUPPLIER LOCATIONS AND DESCRIPTIONS. VER V� J G K5 FLOOR SINK 2" +0" 3-COMP. 51W IF +24" #19 3 EA. GONNEGTION5 K57 K53 T g B GOLD WATER +12" A IGE MAKER +72" #2 1-113 P516, FILTERED O4 VERIFY GAS TYPE (tE. NATURAL OR PROPANE). ALL GAS UNITS TO +0 FREEZER COIL + HEA 7 PED HAVE PRESSURE REGULATOR AS REQUIRED AND ADJUSTED FOR 2-0 A� B COOLER COIL 1" +72" #8 3/4 GRATE LOCAL ALTITUDE AND ENVIRONMENTAL CONDITIONS. GAS BE 5'-b" 5'-b" K3B A CONNECTED WITH QUICK DISCONNECT FLEXIBLE HOSE CONNECTIONS. KB FLOOR 51NK 2" +0" 2-6OMP.51NK IF +24" #27 2-GONNE6TION5 KII - Kq H4C WATER +12" 2-6OMP. 51NK " +40" 27 O ALL PIPING INTO AN INDIRECT WASTE SHALL BE SEPERATEK BY A FULL L JAR KS 2 -2" KIO FLOOR SINK A ICE MAKER +52" #2 AIR GAP. PER UPC 601 (b) ALL WATER CONNEC110NS TO KITCHEN L 0 G 5'-b" EQUIPMENT (IE DISHWASHER, GARBAGE DISPOSER, ETC.) SHALL K21 B ICE MAKER 3/8" +52" #2 BE THRU APPROVED VACUUM BREAKERS. ELECT. G ICE BIN 1" +6" #2 6 ALL SUCTION & LIQUID REFRIGERATION LINES SHALL BE INSTALLED & G KII H4G WATER }�" +12" 3-COMP. 51NK }1" +40" #19 2-CONNEGTION5 [� 3" 4-0^ O INTERCONNECTED WITH REMOTE REFRIGERATION UNIT #001 AS REQUIRED. B 1, KI2 FLOOR 51NK 2" +0"' A D15HHA94FR 2" +8" #17 EXTRA DEEP F.5. B ' 13DISHWASHER 2" +8" #17 STp�¢ Ku A K41 G 6005TER HEATER +24" 23 RELIEF VALVE REFRIDGERATION NOTES J F-j3� 02 _3' D DIRTY D15H TABLE+32" #13 DRAIN TROU&H a DIEM A K13 NOT U5ED E DIRTY DISH TABLE+32" 3 PRE RINSE 51NK I (- �I 5'-b" COFFEECOUNTR K14 HdG WATER " +12" PRE -RINSE SPRAY +40" #16 1. GENERAL CONTRACTOR K15 6A5' +12" FRYER +9" #58 10000 BTUH' A. CONTRACTORS SHALL VERIFY ALL DIMENSIONS AND COORDINATE K WITH OTHER TRADES. KIb 6A5' +12" FRYER 4" +9" 58 122,000 BTUH' KI-1 FLOOR SINK 2" +0" A T TA 1" +6" 46 F End E DRAIN B. GENERAL CONTRACTOR SHALL PREPARE AND WEATHERPROOF THE PLATFORM AND CURBED OPENINGS. E K B +6" 46 FLEXIBLE DRAIN 2. REFRIGERATION CONTRACTOR KIOT KI8 H4G WATER +12" TT TAN . +40" 46 FILL FAUCET A. ALL COPPER TUBING TO BE REFRIGERANT GRADE A.C.R. OR TYPE ELECT, K4`1 ® , KIq GOLD HATER +12" A R ' +3 " 43 L". ELECT, K20 6A5' 1 " +12" RA 11" +33" 42 60 BTUH' B. SILVER SOLDER AND/OR SIL-FOS SHALL BE USED FOR ALL ® 00 -- 3" K21 HOT HATER +12" R H +33' 23 1400E CONNECT TO D.W REFRIGERANT PIPING. SOFT SOLDER IS -NOT ACCEPTABLE. - _ C. ALL PIPING TO BE PRESSURE TESTED NTH NITROGEN AT 300 r-q• 5'-b' K22 6A5' +1 Y +18" 41 50 BTUH' PSI. AFTER THE CONDENSING UNIT AND COIL HAVE BEEN K23 GAS' +12" FRYER +9" #52 122 BTIAT' CONNECTED, THE BALANCE OF THE SYSTEM SHALL BE LEAK TESTED J 7r-Y m� ® K24 +12" FR R +9" 52 122 BTTIH' WITH ALL VALVES OPEN. - -- A�G K25 0A5' " +12" GROOVED GRILL 4" +30" 53 50,000 BTUH• D. THE COMPLETE SYSTEM SHALL BE EVACUATED WITH VACUUM PUMP. '�T- - - - E. CHARGE, TEST, AND ADJUST EACH UNIT TO.:BE IN AN OPERATIONAL 4'-0" _ -- K26 FLOOR SINK I +0" STEAMER 1 +12" 43 i7 K27 6A5' i' +12" GRILL 4" +30" 54 131BTUH' SYSTEM. K28 GA5 " +12" 4-BURNER HOT PL " +30" 57 80 I3TUH+ F. REATER IN FREEZER CONTRACTOR TO PROVIDE AND INSTALL DRAIN LINE HEALER IN FREEZER TO BE CONNECTED BY ELECTRICAL CONTRACTOR K2g GA5' 4" +120 GRILL 4" +30" #54 62 B7U1+' 3. PLUMBING CONTRACTOR K30 FLOOR SINK 2" +0" COUNTER SINK 1 +24" #73 LF GRATE A. PLUMBING CONTRACTOR TO PROVIDE DRAIN AND OVERFLOW LINE K31 FLOOR 51W 2' +0" A FOOD WARMER 1" +28" #64 HALF GRATE FROM THE EVAPORATIVE COOLER TO APPROVED RECEPTOR. Kb4 O 1 B COUNTER SINK 1 +24" 62 B. PLUMBING CONTRACTOR TO PROVIDE & INSTALL SCH. 40 PVC 1 I _ 3 C D B O G REF BASE 1" 65 DRAIN LINES FOR WALK-IN REFRIGERATION AND FREEZER, }� _ PITCHED 1/4" PER FOOT OF RUN. IN FREEZER, UNHEATED DRAIN 1411 K32 NOT U�fD D FREEZER BASE 0 MAIN GA5 -�-�- I'-Q' LINE MUST BE OUTSIDE OF INSULATION TO PREVENT FREEZING. FEED K3T G 4'-0' K33 HIG WATER )1" +12" COUNTER SINK " +36" #91 TRAP DRAIN LINE OUTSIDE OF REFRIGERATED SPACE TO AVOID BEAK SST K50 I'-3" �pp 4'-0° K_54 FLOOR SINK 2" +0" A COUNTER 51NK 1 +24" #91 HALF GRATE ENTRANCE OF WARM AND MOIST AIR. OFFIM K81 Z5 p 2'-0" 2'-0' g B IGE TEA 015P. +36" 85 VERIFY W/SUPPLIE-R C. PLUMBING CONTRACTOR TO PROVIDE INDIVIDUAL DRAIN LINE FOR K2Y 2 3" _- A D K61 \ 1'-30 G COFFEE MAKER +36" 80A VERIFY TER EACH EVAPORATOR UNLESS OTHERWISE CALLED FOR. 2 g' `J ( > K35 d R " +36" 73 D. ALL PLUMBING INSTALLATIONS SHALL BE IN ACCORDANCE WITH LOCAL CODES. K70 p 3' b^ b'_3" g O g K36 GOLD WA +1 A SODA DISPENSER +12" 82 4. PRE -PIPING 2'-2 WATER FILLER 8 A. ALL REFRIGERANT LINES SHALL BE EXTENDED TO ONE SIDE OF . --- - O b K19 B A K6m B K65 G ICE TEA DI5P. . +36" 85 THE PACKAGE IN' A NEAT. AND ORDERLY MANNER. -- -- B G 8-0 q HALF CRATE B. ALL TUBING SHALL BE SECURELY SUPPORTED AND ANCHORED WITH B K6t K4ti A A � B HOT COCOA DISP. " +36" 81 CLAMPS. PAP b' b" 5' b" COOK G G 3'-0" 3'-0• G FLAVOR RAIL F +30" #96 C. ENDS OF LINES SHALL BE CAPPED AGAINST CONTAMINATION AFTER _ KITCWEN • D D ICE (REAM GAB. 1' +12'. #94 THE UNIT IS COMPLETED. THESE CAPPED ENDS ARE TO BE OPENED 5' O' �� LINE 1 0" K38 R + ONLY AT FINAL CONNECTION OF THE PACKAGE TO FIXTURES. K34 f� K39 WOI' NB IF- 7 KB A �I A K33 A K55 5 8 AF�E i LEI] B K3q ' B FILLER I ^ +36" GOLD ONLY t� ® q - F EZERR KIl KY8 �T_31C_I c K59 G ICE TEA D15P. I " +3C 5 COLD ONLY J 101-0" B C I'-3" Ri 1 3-0. A 3'-0. WAIT1RE85 m _ K40 FLOOR SINK 2" +0" A SODA DISP. +12" 82 HALF GRATE R O L_ -1 K49 K3l STATION = B HATER FILLER 1" +30" 83 K36 V1-O 0_� KYl r T36] C GOLD BEV. D15P. +36" 84 F RESTAURANT 120 North Twelfth Avenue 2'-3" B D JJIGE DISP. +36" 6 VERIFY" W/ SUPPLIER KB B C' F" _A 8'0 8 �- T3� J K41 FLOOR SINK 2" +0" A 50PA D15P. }�" +12" 82 HALF GRATE Pocatello, Idaho 83201 -- 3'-0' 3-0. 3'-6' B WATER FILLER 1" +30' 83 PHONE (206) 232-2511 Op1 K15 c G ICE TEA D15P. %4" +24" 5 Nielson En Ineons°In(� Inc" 12" O K13 12 K42 FLOOR SINK 2" +0" A 51NK 1 +24" 110 HALF GRATE J' FAX (208) 234-0918 fib" - K�' �F-O 8 WATER FILLER 1" +36" 83 Consulting Engineers 2' 6" TZ3 B C IGE TEA D15P. 14" +36" 85 F- D ICE BIN 1" +24` 109 WeRSNIP OF DOCUMENTS 5' b" O - K24 b" K43 4'_2, 1 �6. O # B p K� K43 GOLD HATER j�' +12" A SODA DISP. +12" 2 this document and the Ideas and desk3ns Incorporated hereh, as an Instrument of E ® ® COOLER K9 2'-0" R4 b" A OO K63 O B WATER FILLER " +36" 83 rofessbnal service, is the property of NIEL50N ENGINEERING, INC. and 6 not to be used, E 4�-3" K3 � _ K25 2,_3" - G GOLD BEV. D15P. y4" +36" 4 In whole or In port,fdr my other pra)ect without the written outhorizotbn of an authorized I KB 6" - 2' 3" II' 3" 1' ly' 8' q" D ICE TEA DISP. +36" 85 representatNe of NIEL50N EK&WERIN6, INC. 71_ -1 5'-0' 3'-3" ®� ® -._ _ ______-__ __-_ -__ - __�-.___ __ -- Unouthorized use will be prosecuted to the fullest extent of the Law. K44 GOLD WATER +12' A DIPPER WELL +36° 95 q -0" B HOT COCOA D15P. 14^ +36" 72 Copyright © Igg5 b9: NIEL50N ENGINEERING, INC. 3'-0„ 3' Y-3' PLUMBING ROUGH -IN SCHEDULE G COFFEE MAKER W +36" jaOL K45 HdG WATER " +12" A FOOD WARMER F +4040" #62 HW OUTLET --------- ROUGH IN CONNECTION REMARKS B GOl1NTER 51NK +36" Z I TIP H T IPTI N I T I M MARK - ----- -- I' b" K46 FLOOR SINK 2" +0" A HOT FOOD WARM 1 +28" 906 SLFPLY BALL S.O.V. C) KI00 GA5 ' a +12" PIZZA OVEN 4" +48" FF-2 B ICE PAN 1" +28" 898 SUPPLY BALL 5.O.Y. ® -- KI01 6A5 • 4" +12" PIZZA OVEN 4" +4B" FF-2 K4-t FLOOR 51W 2" +0" COUNTER 51NK IF +24" HALF GRATE TOP D I�KIO2 DIRECT DRAIN IF +12' HAND 51NK IF +18' FF-8 VERIFY H/ SUPPLIER K48 H4 1 " 110 WALK-IN i K103 NtG HATER �!" +12" HAND SINK }�" +30" FF-8 VERIFY H/ SUPPLIER No, REVISIONS/SUBMISSIONS Detee WALK-IN COOLER COOLER K10Z K104 FLOOR SINK 2" +0" GHINESE RANGE 1 +12" FF-18 B TER DI P. GOLD ONLY 3' 6" r-6" 8' 4" - K4g GA5 +12" STEAMER +30" 43 BTUH' l I KI03 FAST FOOD VENC)OR$ K�1 K105 KI04 K105 GA5• 1 " +12" GHINE5E RANGE 11 " +12" F-18 I60/200 BTU/HR• ° K50 GA5' +12" T N +30" 47 80 NH' BUD] ] " GHINESE RAKE " F-181 q ® K51 6A15 I 1coNVIECTION 0 KI@ H d G HATER +12" SINK +30" II'-q" K1O& FLOOR SINK 2" +0" 3-COMP. SINK IF +18" --F- 14 K52 DIRECT DRAIN 1 VER MOP SINK I VER 114 VERIFY 90R K53 HIG WATER +12 MOP SINK vER 114 VERIFY i R 1'-3" KIOq HIIG HATER F +12" 3-WMP SINK +36" f-14 K54 FLOOR 5INK 2" + " A 1 " + 110 HALF GRATE TOP C II-, 4 KILO HdG WATER }�" +12" A FOOD HARMER 1" +28" F-23 FREEZER K108 B FOOD HARMER 1" +28° F-23 � 1 +34_ 1 4 -I iKI09 KIII FLOOR SINK 2' +0" A FOOD HARMER 1" +28" F-23 SUPPLY BALL SO.V. �5 FLOOR SINK 2" +0" A ICE PAN 1" +28" 9A SUPPLY BALL 5.0.V. - --- --_ D p B FOOD HARMER 1" +28° F-23 SUPPLY BALL SO.V. PEPPERONIS �13 K� b B ICE PAN 1" +28" 9B 3' g° KI12 FLOOR SINK 2" +0" FOOD HAR,1ER 1" +28' f-16 SUPPLY BALL 5.O.V, a design build com an G ICE PAN 1" +28" #89C 9 P Y E3 SYMBOL LEGEND SYMBOL ABBREVIATION DESCRIPTION HW HOT WATER Q CW COLD WATER O D.D. DIRECT DRAIN '�-O GAS GAS CONNECTION FS FLOOR SINK 0 1W INDIRECT DRAIN ® REF REFRIGERANT LINE (PROVIDED & INSTALLED BY REFRIGERANT CONTR.) �r 2 e 0 MAGIC � 13 60 DR4,GON\ A A . RESTAURANT LARGE SCALE KITCHEN ROUGH -IN PLAN 1'-3" CA5"IER KIIV 1315 SCALE: 3 1 4 1 5 1 6 1 1 8 K113 HOT HATER " STUB FOOD HARMER +28" F-16 g0" 5011P WARMER }�" +24" #24 80 WEST 990 SOUTH, BFIGHAM CITY. UTAH 84302 (801 784-6507 REFRIGERATION ROUGH -IN SCHEDULE K5b]COLD WATER }1IGE PAN +12" 89A JOBNAME FLTING J TRAVEL PLAZA K57FL SINK 2" 1" +28" 909 9IPPLY BALL V. ROUGH IN _ CONNECTION _ REMARKS T F HARM 1" +28" 908 SUPPLY BALL 5.0.V. SAINT LUCIE, FLORIDA RI TYPE SIZE HGT DESCRIPTION SIZE H GT ITEM _REMARKS FLOOR SINK 2" HOT FOOD HARM I" + 8" 90A SUPPLY BALL 5.O.V. Pi RI REFRIG. LINES TE z " DFA WALK IN FREEZER S+78' #009 INTEREF CONNECT w RRIG. B HOT FOOD WARM 1' +28" 906 91PPLY BALL 5.0.V. DRAWING TITLE l " +78' #009 5Y5. ITEM 0001 A5 REOD K5q GOLD HATER " +12" COFFEE MAKER +36" D PARTIAL PLAN KITCHEN Fa REFRIG. LINES qOTEU DFA WALK IN COOLER ST " +78" #008 INTERCONNECT w/REFRIO. Kb0 FLOOR 51NK 2" +0" A Y R R 1" +28" #108 HALF GRATE TOP ROUGH- IN L +78° OB 5Y5. ITEM IOoI AS REGtb B 50UP WARMER 1" +28" #24 I H4G WATER +12" A +28" 108 REAL DRAWN PROJECT NO. R3 REFRIG. LINES TE +90" REFRIG. BA5E S " +18" 65 INTERCONNECT WREFR16. CDN 515 L ' +18" 65 SY5. ITEM •001 A5 REOb B 8" 24 COIN. T ONLY _ R4 REFRIG. LINES +90" FREEZER BA5E S " +18` 60 INTERCONNECT w/REPRIG. K62 HOT WATER }�" +12" SOUP WARMER }1" +28" #24 HOT WATER ONLY CHECKED SERIES 60 SY5. ITEM A001 A5 REOb K63 HOT WATER }�" STUB HT FOOD WARMER +28" #90 HW ONLY (2) CONN. CDN L-15-200 R5 REFRIG. LINES TE +90" REFRIGERATION S3j;" +90" #129 IKIIERGONNECT w/REFlZ6. Kb4 HOT HATER W STUB HT FOOD WARMER F+28" #90 HW c�Y (2) CONN. REVIEWED DRAWING NO. Q L " +9C' 129 SY5. ITEM A001 A5 READ K65 HOT HATER ' +12" HT FOOD WARMER h1 +28" #90 HOT WATER ONLY COW Rb REFRIG. LINES 40TEL +48' ICE MAKER SW +52' 02 INTERCONNECT w/REFRI6. DATE s #002 5Y5. ITEM 0001 A5 REOV JANW4Rf 191 �✓/ 'GAS NOTE: ALL GAS CONNECIIONS TO BE QUICK DISCONNECT. VERIFY GAS TYPE & ALTITUDE AND ADJUST AS REO.O. R1 REFRIG. LINES TE +48" REFRIG. BASE S%" +90" #066 INTERCONNECT wNEFRI6. GAS LINES TO BE FED FROM MAIN GAS FEED UNDER RETURN AIR CHASE TO WICK DISCONNECT AI LOCATIONS INDICATED SALE 5 Of 11 L%" +90" 1466 5Y5. ITEM "I A5 REO9 9 l0 II 12 1 13 1 14 1 2 3 4 5 b l 8 S 10 11 12 13 14 M '�'41 ® `\ O z,yI / �zv j \ f I P8 M II Z I I/i O 32 CO 21. 2 IFDsx' 2 /2'Vldv vi O PI ®FDI O/'I1 d OJI< rPSP3 22t�IP2 2'= Zi=]' P'7i FD1t+ Pj I lIdV 4 2 TS 2 O'V �t LPI 1 �. �r�� 21 1 �I I I `• � UM' V .. � ��\J �, � I z' � 1 I Fpl 2,y'V II I I \ � y'I I� � I� \ 2t,=,V L l P1 1 2' -' 2' �i'J 'S '�,' ,� �r 11 I FD► PI / ; f ,, z. 2' /I I lC 2v�/I _ CO In (Pi) I 144' ,r" . (PI� "� I mill 2 Y O I' IFDI U21d, FDI I t� r '' �`'I^ 2k" \\, �" PI1 2���; �'' PI. I; n �� zv� �i�l'P!� UP2�k��4 ��} z f - I I� IFDI P6 j P5 w°j+' ! P5 3/4' U� z�= I� dv \ I 1 I z FCO lPl I1� ' Pl� I z- j` (� V 1 \ z \l" �J Pl z' 9�' 3/' �I� i '�i' ( �j OO + • P9 ® y 2 FDI /I I I FDl I I �PS� �i v� _ i i ®i \ \ \,\ ^ J PI P5 z' IFDI II I � P� t�'v FBI \ O PS I I PI. 1f51 zk '�\ PI % IFDH 2 �>I\ �: /' 1 2' 2' T r Plb Pl I \ I 1� 01 O d'U1C0 z FDl 2 l P2 K O ,5 2� 2 JI PW 1 I 1 PI \'v/ / O z �I PI 1 I I FDI K . I O O O' i 2�i' z I I z P16 4 O �v PI I z 1 I P' z z�`'v� 3'yz� P9 WCO / z' 0 Pl r 'S � � � ,,,I� >y, 'a' z'y T' I I I r FDI / \ \ ` �� � I PI6 s - O z,I 2 2�,V \ \ \� �> / PPS PUB�!C TOILET ROOMS WASTE SCHEMATIC p? PS �y 2�i'� e *V�II \I O�'( I I \ P� 2' �I NO SCALE fitO I/ ��J 2 z PI �i P8 I P8 1 3 I 1 \\ SHOWER AREA WATER SCHEMATICZ�I + O PI UKO P8 1 \� 1 U1G0 P4 FDI tR NO SCALE l P3 12 1 P3 �' O I 1 L\I O zv�' 2' O P4 SHOWER AREA l:: ATE SCHEMATIC r I I>\ FDI (P2) II� NO SCALE 1 pl 2 I _2'YiR 2 I I T C I O 114' 2. 34 4. L' P5 3 YiR ,>� 1, PI PI � � PI Od 1 i � 14'L � I.162 L I j PI PI d' Od WCO PI9 L P4 PO OL N WO O Pi 1 P:12 rl 3v I I 1 \'r2 V %� uq PI P1 PI 2 2V36V FSI i T\\\\ IV IV/�i� GI I +' ,+, O PI PI �' ��1 \ O Cs 2'V ��\ I I iT r] \ \ �3'v KI PI j 4 / \ \ \ / / �E, i �, 3/4' ' , I GIS O O I 26V \ I I rF-51/' FGd / \ \ 3 v� ' ^ FBI FDI 2'V / r a' ,,4. �4 , ,,+. cl3 d' QOTCs I IFSI z'v FD3,- FBI '. FCO KI ��/3' z'�� I' a' FBI13' �� FBI 2'V�/ .- 2/' r P9 2'v 2' / FBI FBI ' ' r F51 1r�2' ' / '+' / i WATER I 1..t n rim O PCp FBI / 1 �d �2,V 1 wcc) o PZ� IC TOILET ROOMS WA I ER SCEs I A 3' � 1 PI / / _ CAN WA5H z V%� 2'1/rR �� /' 1 I \UICO 1 FBI 13' FCO 2' I 2v ® r KII P22// NO SCALE - F I l \ / / FBI yt K 21 K4 , , 4' 1V I z'y I 2y2'YiR J �'- / J z 1 z.1 __ _ -�y,'_ _ Cw__ _ - _ , , 1 4 !/ co -F 2 v� I Jt I fSll J ' WGO 94'J _ - / 120 North Twelfth Avenue I I 2v 1 I (P6� v v / 1 Klo FSI 2ti�� I IT J� , / / —' 1 I FD3 I FSI I \ \ FBI �J 2' 2 I I / / Pocatello Idaho 83201 1JCO I 1 FD2 1C0 ©Fsl�f FAST FOOD WATER SCHEMATIC �`' ' Nielson En lneerin Inc, PHONE (208)232-2511 g g� FAX (208) 234-0918 FD3 F61 2' I 2.V� / FD2 2 3, FBI 3, FAST FOOD WASTE SCHEMATIC t StATION$5 NO SCALE J Gonsulting Engneers FD3 4! 4' 1 FD2 3 3. I' �z v NO SCALE OI11NERSHIP OF DOCUMENTS E P6 I This document and the Ideas and designs Incorporated herein, as an Instrument of FBI 3' i \ professional service, is the property of NIEL50N ENGINEERING, INC. and is not to b-- used, E _ > Crn3' 1 I`'►�I ` 3 �/� in whole or In pertjor any other project without the written authorization of an authorized r ;4 4' \ ' \ \ \ zi ((! I representative of NIEL50N ENGINEERING, INC. d' d, I �� \ \ \ I `1 FCO ,,4,�� I I ( Lhauthorized use will be proseated to the fullest extent ol` the Law. FDI I FDI (O T JFSI '� �f> l ' FCO Pj 2'v \ \,,4. e�34, 1 �. Gopyrot © IG98 by: NIEL50N ENGINEERING, ING. 4' F UJAITRE55 OS l/ Pl\l O L n , �� I i i\ \ I i% / I�'4' STATION �I D {�� + A114. lid' KITCHEN WASTE SCHEMATIC •�,,' I,°{� I'�' �� BUFFET . \ 4' 1�' It'=' TABLES I NO SCALE 2 \ 14=' %' No. REVISIONS/SUBMISSIONS Date \ I N 0 i ROOF DRAIN LINE SCHEMATIC_ NO SCALE 2 3 I:I 15A0KFLOW/PRE55URE REGULATOR 4. FT.) D 1.1 r=7 O3/4' 2' I' III 'J/ ----- 1 '/4 , L ll2I' J r = - P13 . t OP13 ' a design build company / 80 WEST 900 SOUTH, BRIGHAM CITY, UTAH 84302 1801 734-6807 " NAME FLYING J TRAVEL PLAZA ' /4' SAINT LUCIE, FLORIDA r DRAWING TITLE ----- 6 PLUM IWG oftSC EMMATICS O / SEAL DRAWN PROJECT NO. cDH 96515 h' r 2-GOMP�'4 4' CFIECIKED SERIES SINK CDH L-15-200 REVIEWED DRAWINCs NO, A KITCHEN WATER SCHEMATIC DATE. ICE MAKER DAl'!=• NO SCALE JANUARY 1998 - SCALE I.I 6 of ll 1 8 9 10 1 11 12 13 14 c I , ? . 3 , . 4 5 KEY NOTES TO SHEET P-7 INSULATION SCHEDULE I CONTINUED MAIN LEVEL PLUMBING PLAN SHEET P-2. O SYSTEM TYPE FLUID TEMP. RANGE (' F) INSULATION TYPE M ODROP IN WARM WALL WITH HOT & COLD WATER LINES. DOMESTIC HOT & COLD 40' - 180' 1" FIBERGLASS w/ VAPOR O3 HOLD WATER LINES TIGHT TO UNDERSIDE OF COUNTER TOP. WATER ABOVE FLOOR BARRIER OR IMCOA ODROP DOWN WALL WITH CW & HW TO BELOW FLOOR, RUN TO FIXTURES DOMESTIC HOT & COLD 40' - 180' 1/2" IMCOA INDICATED. INSULATE UNDERFLOOR LINES WITH %' IMCOA. NO JOINTS WATER BELOW SLAB UNDERFLOOR. SEE DETAILS 4 & 5/P-DI, ROOF DRAIN & 35" - 100' 1" FIBERGLASS w/ VAPOR PLUMBING ZONE BALL VALVE FOR INDICATED ZONE EXPOSED AT CEILING. SEE O OVERFLOW DRAIN BARRIER DETAIL 5/P-D3. SEE SHEET P-2 FOR ZONE LOCATIONS. REFRIGERANT 35' - 140' 1/2" IMCOA L O PROVIDE & INSTALL WOODFORD MODEL 24 HOSE BIBB NTH METAL WHEEL HANDLE AT 3'-6' AFF (HW & CA) FOR JANITOR -CLEANING SYSTEM. MOUNT SERVICE SINK FAUCET AT 24' AFF. PROVIDE & INSTALL WATTS NO. L7 DOUBLE CHECK VALVE IN EACH HW & CW LINE TO SERRVICE SINK. OINSTALL FLUSH VALVE HANDLE ON WIDE SIDE OF STALL ON THIS FIXTURE. O NOT USED OINSTALLISLAND LOOP VENT ON THIS FIXTURE, SEE DETAIL 1/P-D3. K 10 6' PVC BEVERAGE CONDUIT EXTENDED 4" THRU FLOOR AT BOTH ENDS & TEMPORARY CAP. INSTALL PULL CORD. SEE DETAIL 2/P-D3. II PROVIDE & INSTALL HANDI LAV-GUARD No. 102G TRAP AND SUPPLY INSULATION KIT ON THIS FIXTURE. J Cs I: E F• Ce IQ A 9 0 2 3 z C13 C19 GI Cll C15 ICE POST MIX 5LU&4 HOT MACHINE CHOCOLATE MAKER CE DppNQT TEA DIwvPE1.11iER a CA31:: — — -- o MACHINE MICROWAVE ILL 0000 0000 on io of no 3 DELI COUNTER ELEVATION e SCALE: 1/4' = I'-O' 4 9 6 I 1 I 8 9 10 II 12 13 14 CONVENIENCE STORE EQUIPMENT EDULE PLUMBING FIXTURE SCHEDULE 71 ' S (EQ). ALL PLUMBING EQUIPMENT AND INSTALLATION BY PLUMBING CONTRACTOR * UNIFORM PLUMBING CODE FIXTURE UNITS. EQUIPMENT SUPPLIED & SET BY SUPPLIER INDICATED ON FACILITIES EQUIPMENT DR- ROUGH -IN & FINAL PLUMBING CONNECTIONS BY PLUMBING CONTRACTOR. REFER TC DRAWINGS FOR EXACT _ PROVIDE SPECIFIED ITEMS OR APPROVED EQUALS. (REFER TO SPECIFICATIONS) M ROUGH -IN, CONNECTION REQUIREMENTS LOCATIONS & DIMENSIONS. ALL HOT & CO,, ,TER CONNECTIONS TO - -- ---- — WATER WASTE WATER WASTE EQUIPMENT SHALL BE MADE THRU VALVES OR STOPS AND BRAIDED STAINLESS STI FOR PLUMBING FIXTURES. ONNECTORS EQUAL TO ISYMBOLDESCRIPTION GW HW V W R THOSE SPECIFIED SYMBOL DESCRIPTION _ CW HW V W UNITS T UNITSR UNITSR UNITS WASHER CONNECTION - GUY GRAY 0-200. PROVIDE w/ 2-WATTS MODEL N0. 8 P1 WATER CLOSET - KOHLER K-4350 WELLCOME LITE WATER -GUARD VITREOUS CHINA 1" - 2• 4' 10 6 NUMBER DESCRIPTION CW HW V W IOU REMARKS P16 VACUUM BREAKERS ON HOSE CONNECTIONS." �" 11/t" 2' 4 2 O SIPHON JET ELONGATED BOWL w/ 52048 BOLT CAPS, K-4670-C SEAT AND SLOAN ROYAL 110-1.5 1.5 GAL. FLUSH VALVE. O� Ct SLUSH MACHINE - _ - _ P17 DRYER CONNECTION - PROVIDE AND INSTALL 3/4" GAS DRYER CONNECTION THRU _ _ _ _ - - P2 HANDICAP WATER CLOSET - KOHLER K-4368-ET HIGHCUFF LITE WATER -GUARD 18" 1' - 2" 4" GAS COCK. HIGH VITREOUS CHINA SIPHON JET ELONGATED BOWL w/ K-4562 BOLT CAPS, 10 6 C3 SANDWICH MERCHANDISER - - - - 2" TO FS BARBER SINK - ELKAY BPSFR-1215 STAINLESS STEEL SINK (12 1/2" X 15") 18GA, K-4670-C SEAT AND SLOAN ROYAL 11G-1.5 1.5-GAL. FLUSH VALVE. (USE SLOAN 110- "WIDE P18 TYPE 302, SELF RIMMING, PROVIDE WITH BRASSCRAFT HCRX ANGLE STOP .& C FLUSH VALVE WITH HANDLE ON RIGHT WHERE REQUIRED FOR SIDE OF STALL") L C9 CAPPUCCINO" - - - - { BRAIDED STAINLESS STEEL SUPPLIES, ELKAY LH-4121 FAUCET 8' REACH 10" GOOSENECK WITH SINGLE LEVER,LK-8 GRID DRAIN, WADE W-5751-1/2SO-44 1 1 2 2 P3 URINAL - AMERICAN STANDARD NO. 6601.012 LYNBROOK 1.0 URINAL, VITREOUS CHINA 1" 2' 2' C11 HOT CHOCOLATE " - - - - HAIR AND SOLIDS INTERCEPTOR. BLOWOUT WITH SLOAN NO. 186-1 1/2' FLUSH VALVE AND WADE W-400 CARRIER, 5 6 BARBER SINK - #3800 ALPHA AS MANUFACTURED BY BELVEDERE CO. OF ROCKFORD, C13 ICE TEA DISP. Y4 IL. COMPLETE WITH #622-228-C TEMP. WITH DIVERTER, #39 FLOTROL PRESSURE BALANCE, #403 COMPLETE VACUUM BREAKER, #5090035B 'WHIZ SPRAY AND HOSE, P4 HANDICAP URINAL -SAME AS P3 EX CEPT MOUNT SO LIP OF URINAL IS 17" AFF. Y4" - 2" 2'5 6 C15 COFFEE MAKER Yy -- p218 STRAINER &TAILPIECE, BRASSCRAFT HCRX ANGLE STOP &BRAIDED STAINLESS STEEL SUPPLIES & WADE W-5751-yr-50-44 }�' }�" 1}�' 1)¢' p 2 P5 LAVATORY - KOHLER K-2214 LADENA LAVATORY 18" X 12" WITH 52047 CLAMP COLOR PER Yz" fit" 1j� 1}� C18 O _ ASSEMBLY FOR MOUNTING UNDERCOUNTER TOP. (NO EQUALS ACCEPTED). 2 2 DECAF. COFFEE MAKER' HAIR & SOLIDS INTERCEPTOR. COLOR SHOULD BE E018 BEIGE. ARCH. BRASSCRAFT HRC19ZSTOPS & SI-12A BRAIDED STAINLESS STEEL SUPPLIES, C19 POST MIX DRINK DISP. • - - YC AIR REEL — COXWELL NSRU-135 UNDERGROUND RETRACTABLE AIR REEL SEE EQUIPMENT (EQ) DRAWINGS FOR IN (W AIR). PROVIDE & INSTALL COXWELL - - - FAUCET WITH EXTRA LONG LEVER HANDLE, KOHLER K-7715 K-15598-5 CORALAIS LAV FFA --- _ ZO 7 GRID STRAINER & TAILPIECE, K-8898 1 1 4 CAST BRASS P-TRAP. C27 WALK-IN COOLER - - - 1" TO FS No. 10754 DUAL FOOT TRUCK AIR CHUCK. COXELL PH. 800-229- 335. AIR/WATER REEL - COXWELL #CRU-135-135 UNDERGROUND RETRACTING -AIR/WATER C31 ICE MACHINE" - - -•� TO FS HOSE REEL COMPLETE w/ 120V HEATER & HONEYWELL T-STAT CONNECTED IN P21 LINE, 250 PSI HOSE, /10757 RADIATOR BIBB STEM FOR WATER HOSE & COXWELL _ _ _ 5 _ P6 HAND SINK - KOHLER K-2005 KINGSTON VITREOUS CHINA WALL MOUNT LAVATORY • , 1j�' 1j * 2 2 Mt COIN OPERATED DRYER STACKED - - - - NT TO OUTSIDE No. 10754 DUAL FOOT TRUCK AIR CHUCK (WHERE WINTER TEMP. DOES w/ 4" FAUCET CENTERS DRILLED FOR CONCEALED ARM CARRIER. PROVIDE & INSTALL NOT FALL BELOW 32T HEATER SECTION MAY BE OMITTED. VERIFY w/ ENGINEER & COMPLETE w/ BRASSCRAFT HRCI9Z-C ANGLE STOPS & SI-12A BRAIDED STAINLESS M2 COIN OPERATED WASHER 2" P PLUMB. FIX. P16 COORDINATE w/ E.C.) 1/2' AIR, COXWELL PH. 800-229-7335. STEEL SUPPLIES, DELTA 501-HDF FAUCET, KOHLER K-7715 GRID STRAINER, K-9000-1- HANDSINK - ELKAY BLR-15 STAINLESS STEEL SINK WITH 2 FAUCET HOLES, 18 GA. 1/4' CAST BRASS P-TRAP AND WADE W-520-07 CARRIER. M4 HOUSE DRYER STACKED - - - - - 1" 1 Yt" Yt 2 2 1 NT TO OUTSIDE 22 TYPE 302 STAINLESS STEEL PROVIDE. &INSTALL WITH BRASSCRAFT HCRX ANGLE STOP HAND SINK - KOHLER K-2007 KINGSTON VITREOUS CHINA WALL MOUNT LAVATORY & BRAIDED STAINLESS STEEL SUPPLIES, LK-4121 SINGLE LEVER FAUCET, LK-8 NTH WALL BRACKET AND SINGLE FAUCET HOLE. DRILLED FOR CONCEALED ARM CARRIER. M5 HOUSE WASHER }�" �Z" 1>%7" 2' i- PLUMB. FIX. P16 2' C.P. GRID STRAINER KOHLER K-9000 P-TRAP. P6A SUPPLY AND INSTALL COMPLETE WITH KOHLER K-13816 WALL MOUNTED SELF -CLOSING 1/1" }�" 1Yz" 1Yz" 2 2 AIR REEL - COXWELL #EN150 ENCLOSED AIR REEL PATH 1 4 X 50 HOSE AND AIR FOOT CONTROL MIXING VALVE, K-13721 SUPPLY TO SPOUT WITH LOOSE KEY VOLUME P23 CHUCK SAME AS P20. SEE EO SHEETS FOR INSTALLATION. - - - REGULATOR, K-13760 HIGH GOOSENECK SPOUT WITH AERATOR, K-7715 DRAIN WITH FLOOR DRAIN - J.R. SMITH NO. 2005-B CAST IRON FLOOR DRAIN WITH 5'X5 SQUARE PERFORATED STRAINER, 1-1/4" TAILPIECE, K-9000 1-1/4" CAST BRASS P-TRAP, AND - - 2' 2• - 2 WADE W-520-07 CARRIER. FDt NICKEL BRONZE STRAINER. SHOWER - VANDAL No. RESISTANT, POST -TEMP SHOWER VALVE WITH STOPS, PRESSURE FLOOR DRAIN - J.R. SMITH NO. 2005-K CAST IRON FLOOR DRAIN WITH 50X5" SQUARE FD2 - 2" 2" - 2 P� BALANCED, VANDAL RESISTANT, WITH MOEN No: 12875 CHROME DELUXE SHOWER HEAD, �+' �" 1�. 2" 4 2 REINFORCED POLISHED BRONZE STRAINER 2. OUTLET. ARM & FLANGE 2.5 GPM NO EQUALS ACCEPTED PROVIDE & INSTALL FD1 FOR DRAIN FD3 FLOOR DRAIN - J.R. SMITH NO. 2010 C-10 CAST IRON FLOOR DRAIN WITH 10" P.B. - - 2" 2' - 2 HANDICAP SHOWER - BRADLEY HN-300-EF-3-THV-SF-LBJ w/ No. 780 FD4STRAINFIR AND 4" OUTLET, P7A EQUA—FLO PRESS. BALANCE MIXING VALVE, DIVERTER VALVE w/LEVER HANDLE, HAND FLOOR DRAIN — ACO POLYMER PRODUCTS INC. SYSTEM FS100 WITH CHANNEL NO. 412, HELD SHOWER SPRAY w/59" S.S. HOSE & POST MOUNTING BRACKET, IN -LINE BACKFLOW Y4" Y4" 1�' 2' 4 2 GRATE NO. 410, CLOSING END CAP AND OUTLET END CAP. (4" OUTLET) 2" 4" 1 PREVENTER w/QUICK DISCONNECT FOR HOSE, No. 442 DELUX SHOWER HEAD w/TEE FLOOR SINK - J.R. SMITH NO. 3150-12, 12'SQ. X 8" DEEP. CAST IRON FLOOR SINK. HANDLE VOL CONTROL & LOCKABLE BALL JOINT. GRAB BARS & SEAT BY ARCH. DRAIN FSl WITH ACID RESISTANT COATED INTERIOR, 1/2 NICKEL BRONZE RIM & GRATE, 2" OUTLET — — 2' 2' — 1 SHALL BE FD1 FS2 FLOOR SINK — J.R. SMITH NO. 3150-12, 12'SO. X 10' DEEP. CAST IRON FLOOR SINK. _ _ 2• 4" — 2 WITH ACID RESISTANT COATED INTERIOR, 1/2 NICKEL BRONZEI A 4' OUTLET HB1 HOSE BIBB - WOODFORD MODEL 865 AUTOMATIC DRAINING, FREEZELESS WALL HYDRANT - MOP SINK - KOHLER K-6710 WHITBY CONER FLOOR SERVICE SINK , ENAMELED CAST WITH INTEGRAL VACUUM BREAKER & BACKFLOW PREVENTER. Yi" 5 P9 IRON WITH K-8940 COATED WIRE RIM GUARD, K-9146 3" PERFORATED STRAINER, AND Y4' Y4' 2" 3" 4 6 HB2 HOSE BIBB - ACORN 8151 SINGLE TEMP. STAINLESS STEEL WALL HOSE BOX w/ Yy _ _ 5 K-8928 POLISHED CHROME SINK FAUCET WITH VACUUM BREAKER & HOSE. DOOR AND VACUUM BREAKER. SEE DETAIL 8 P-D1. WATER HEATER - A.O. SMITH BTC-500A (500MBH) GAS WATER HEATER, (ASME) 69 GAL HOSE BIBB - WOODFORD /W34 FREEZELESS YARD HYDRANT. DEPTH OF BURY pjD STORAGE X3=207 GAL. AVAILABLE. RECOVERY OF 455 GPH (EACH WATER HEATER) H83 TO BE 12" BELOW FROSTLINE. DRAIN AT BASE TO BE SET IN 24"x24•x24" PEA GRAVEL �" 5 X3=1365 GPH AT 100T TEMPERATURE RISE. SET DISCHARGE AT 130T. 9' FLUE EACH. 2' 2" - - SUMP. SEE DETAIL 9 P-D3. PROVIDE & INSTALL W CASH -ACME No. VB-222 VAC. BRKR PROVIDE & INSTALL w/ THERM-X-TROL fST-25V, 10.3 GAL. THERMAL EXPANSION SW HOSE BIBB - WOODFORD-MODEL NO. HC 865 HOT & COLD MIXER, AUTOMATIC ABSORBER, SEE DETAIL 1/P-DI. (PROVIDE PROPANE (L.P. GAS) MODELS WHERE H64 �i �i" - - 5 - AWING, FREEZELESS WALL HYDRANT WITH VACUUM BREAKER & BACKFLOW PREVENTER REQUIRED) (10" FLUE)O - ROOF DRAIN -J.R. SMITH NO.1010-RC-CID CAST IRON ROOF DRAIN W/ FLASHING CLAMP - - - - - - P11 205CIRWATTS, PUMP - GR2515 R UP 26-96 BF CIRCULATING PUMP, 1 FEET OF 115v, RD SUMP RELIEVER, UNDERDECK CLAMP &CAST IRON DOME, 4" OUTLET. SEE DETAIL 11/PD-1 CON WATTS, H1.H AMPS, 2515 RPM, MATH CAPACITY OF 5 GPM QUA FEET OF HEAD. CONTROL WITH HONEYWELL T-675A-1441 SURFACE MOUNTED AOUASTAT. OD OVERFLOW DRAIN - J.R. SMITH NO. 1080-RC-CID CAST IRON ROOF DRAIN WITH HAND SINK - HAND SINK SHALL BE INTERGRAL PART OF STAINLESS STEEL COUNTER FLASHING CLAMP, SUMP RECIEVER, UNDER DECK CLAMP, CAST IRON DOME AND 2' HIGH - - - - - - TOP. FAUCET AND DRAIN SUPPLIED BY OWNER, INSTALLED BY P.C. SUPPLY & INSTALL DAM. 4" OUTLET. SEE DETAIL 12/PD-1 P1 WITH BRASSCRAFT HCRX ANGLE STOPS & BRAIDED STAINLESS STEEL �" �" lYz" 1}67 2 2 SUPPLIES, CONNECT TO DRAIN AND EXTEND TO DRAIN INDIRECTLY INTO FLOOR SINK. ALL FINAL PLUMBING CONNECTIONS BY P.C. WATER SOFTENER PURCHASED THROUGH CULLIGAN NATIONAL ACCOUNT PROGRAM. EQUIP _ 2W P13 MENT PURCHASED & INSTALLED BY PLUMBING CONTRACTOR, START UP PERFORMED BY LOCAL CULLIGAN DEALER. PLUMBING CONTRACTOR SHALL CONTACT NATIONAL ACCOUNT -- REPRESENTATIVE FOR FLYING J: DAVID ROBERTS (801) 487-7528 FOR DETAILS & I' QUOTATION. ANTICIPATED FLOW RATES 60 GPM CONT, 75 GPM PEAK, 15,000 GPD. HALL I-�0) 3'� I I I OTHER ACCEPTABLE MANUFACTURERS: BRUNER, COLUMBIA, KINETICO, MARLO. PLL MEIN FOR Zoi PARTIAL PLAN PUBLIC TOILET ROOMS PLUMBING l SCALE: 1/4' =1'-C' A 1 G NIiRRED IT14 WATER AIR COMPRESSOR - INGERSOL-RAND MODEL 5N, 5 HP, 480 V. 3 0, 985 RPM, P14 19.7 CFM DISPLACEMENT, 15 ACFM 0 150 PSI MOUNTED ON 80 GAL VERTICAL ASME TANK. COMPLETE w/ STARTER, SAFETY VALVES, FLEX AIR CONNECTORS, • WILKERSON C26-04-000 COMBINATION FILTER, REGULATOR AND LUBRICATOR AND ALL OTHER EQUIPMENT REQUIRED FOR COMPLETE AND PROPER INSTALLATION. 3 4" AIR DISCHARGE. SEE DETAIL 14 P-D1. GREASE INTERCEPTOR - REFER TO DETAIL 11/P-D2. PRECAST OF SIMILAR P15 CONSTRUCTION & CAPACITY ACCEPTABLE (PROVIDE SHOP DRAWINGS). 4" INLET, 4' OUTLET, 2" RELIEF VENT, 3" LOCAL VENT. No. I PREVISIONS/$U15I`1165ION5 I Date a design build company 50 WEST 990 SOUTH, BRIGHAM CITY, UTAH 84302 (801) 734-6607 JO" FETING J TRAVEL PLAZA _ 120 North Twelfth Ave - SAINT LUCIE, FLORIDA Pocatello, Idaho 83201 ----- --- PIaDNE (208) 232-2511 DRAWMG TITLE Nielson Engineering, Inc. FAX(208)234-0918 PLUMBING 5CNEDULE5 Consulting Engineers AND DETAILS SEAL DRAWN cDH PROJECT NO. C36515 00ERSHIP OF DOCUMENTS CHECKED BERI96 This document and the Ideas and designs Incorporated herein, as an Instrument of a>W L-15-200 ofes5lonal service, is the property of NIEL50N EN6INEERIN6, LNG. and is not to be used, REVIEWED DRAWMG No. whole or in part,For any other project without the written authorizatlon of an authorized CD 4 representative of NIEL50N EN6INEERING,ING. DATE Uncwthorized use will be prosecuted to the fullest extent of the Law. JANUARY 1998 Gopyright © 199b by: NIEL50N ENCINEERIN6, INC. SCALE =1 of 11 12 1 13 1 14 K J 11 C: F E 9 C 0 112 ig(9