Loading...
HomeMy WebLinkAboutSLC FIRE DEPT - PLAN REVIEWP.O. BOX 3030 i' FT. PIERCE FL. 34948-3030 2400 RHODE ISLAND AVE. Fr. PIERCE FL. 34950 I: I ST. LUCIE COUNTY FIRE DISTRICT BUREAU OF FIRE PREVENTION TELEPHONE (561)462-2312 FAX NO. (561)-462-2323 PLAN REVIEW • I' JURISDICTION: St. Lucie County OCCUPANCY: Flying "J " Travel Plaza ADDRESS: 100 N.jktngs Hwy. CONTRACTOR: Mathews Corp. ARCHITECT/ENGINEER: P.D.G. BUILDING OWNER: OCCUPANCY TYPE: Assembly "B" GROSS SQ FT: 19,320 sq ft OCCUPANT LOAD: Indicated below CONSTROCTION;TYPE:( NFPA-220) Type: II (III) SCANNED BY St. Lucie COW% F.P.B. NO: 6696 BUILDING DEPT. NO: TBA. NO. OF STORIES: One PHONE NO: (813)-871-3710 PHONE NO: (801)-734-6407 REVIEW DATE: 9-22-97 AUTOMATIC SPKLRS: Yes NET SQ FT: 18,320 sq ft. BASED ON: Indicated Below SBCCI: Type: IV - Protected New Construction;, X Automatic spklr: Contractor: Tenant Improvement: Fire Alarm: X ' Contractor. Shell Only: Fixed Fire suppression: X Contractor. Addition: j I Hood & Duct System: X Contractor: Renovation: ;; Fuel Storage: X Contractor: 1. All revisions must be In compliance before the final Inspection. 2. The Fire Marshal requires 24 hr. notice on all Inspections. 3. The Building Departments schedule all final inspections by the Fire Marshal. li 1. Separate safeguards and occupancy separation are impractical with this mixed occupancy, so the building must be classified as the most restrictive type and that being Assembly, Class "B". ( i ' 2. ' The Occupant Load is based on the following: 3. F Proper 288 persons Based on 15 sq ft per person p 11 Based on 15 sq ft per person 32 Based on 15 sq ft per person Store 56 Based on 30 sq ft per person nge 35 Based on 15 sq ft per person rea 42 Based on 100 sq ft per person ant load 424 " an additional fire extinguisher for the kitchen area. Mount between to F. appliances and the exit access door. Flying "J" Travel;Plaza February 18,1998 Page 2. 4. Permitting: a. A separate permit and review is required from the Fire Marshal's office and artment for the installation of the automatic Sprinkler system. (See Building Dep attached requirements). b. A separate permit and review is required from the Fire Marshal's office and the Building Department for the installation of the fire alarm system. (See attached requirements). I, c. A separate permit and review is required from the Fire Marshal's and the Building Departmentoffice for the hood and duct exhaust ventilation system in the kitchen. d. A separate permit and review is required from the Fire Marshal's office and the Building Department for the fixed fire protection system that is required for the hood, duct and suifiace protection system. e. A separate permit and review is required from the Fire Marshal's office and the Building Department for the installation of the underground flammable and combustible liquid storage tanks. Four (4)Sets of plans and specifications shall be submitted to The St. Lucie County Department .of Environmental Health for their review and ;stamp. (See attached requirements). 5. Panic Hardware Note 2. Material key legend, sheet A- 9.1 referring to signage that the doors must remain unlocked. ThelLife Safety Code NFPA 101, permits a lock or latch only if they are panic hardware when serving an occupant load in excess of 100 persons. The exception being, that,the panic hardware is not required for the main entrance/exit when serving an ;occupant load of less than 200 persons. Because the occupant load is over 200 persons, panic hardware will be required on all of the following doors. 101-01, 101-02, 138-63, 139-63, 37A-62, and 115-37. 6. Automatic Sprinkler system: a. ;Fire Department Connection. The F.D.C. is indicated in two locations. One is wall mounted near the riser and the other is free standing. The F.D.C. may be either free standing or wall mounted but, a dry pipe system requires that the F.D.0 be connected to the system riser between the system control valve and the dry pipe valve as indicated on sheet FS-2 Flying "J" Travel February' 18, 19! Page 3. 7. b. The automatic sprinkler plans and calculations shall be signed and sealed by the architects engineer of record. The architect shall forward a letter to the Fire Marshal's office indicating who the engineer of record will be. The engineer of record shall indicate the Point of Service on the Site Plan. The Point of Service shall be where the underground piping becomes exclusively for the automatic sprinkler system. This will be at the Tee separating the domestic and fire main. The sprinkler, calculations shall be carried back to the point of the fire flow test hydrant. Thelcontractors plans need not be signed or sealed by the engineer of record if the design has not changed. Provide additional information on the dry pipe valve, indicating the pressure pump, accelerators l'. etc. The system indicated is a manual system with a internal audible alarm and visual indicating appliances. N.F.P.A. 101 requires a voise evacuation system in accordance with 101-8-3.4. a. lhitiatioh' shall be by manual means (pull stations) provided with a emergency powe, source. The initiating device shall be capable of transmitting an alarm to a receiving station, located within the building, that is continuously attended when the assembly occupancy is occupied. b. Notification: The required fire alarm system shall sound an audible alarm in a constantly attended receiving station within the building when occupied for the purpose of initiating emergency action. c. „Occupant notification shall be by voice announcements, either live or pre-recorded, initiated by the person in the constantly attended location. d. The announcement shall be made via an approved voice communication or public address system, provided with an emergency power source, that is audible abo�e the ambient noise level of the assembly occupancy. e. ,A single manual pull station will be required at the constantly attended location which, when activated will initiate the visual indicating appliances.