Loading...
HomeMy WebLinkAboutPLANSRfOeftD SFP 18 ?O1g Pefmltting p® St. l.ucle C6Unlyent • STATE OF FLORIDA CERTIFIED BUILDING CONTRACTOR: DR HORTON HOMES 1430 CULVER DRIVE NE PALM BAY, FL 32907 TEL: (321) 733-7092 FAX: (321) 733-7972 • STATE OF FLORIDA PROFESSIONAL ARCHITECT: MICHAEL C. ANDERSON AR NO. 17305 A.B. DESIGN GROUP, LLC 551 S. APOLLO BLVD. SUITE 202 MELBOURNE, FLORIDA 32901 Tel: (321) 802-3591 Fax: (407) 774-4078 I DRAWING / CONTRACT DOCUMENT I REVIEW BY BUILDER THE BUILDER ASSUMES ALL LIABILITY FOR INTERPRETATION OF THE CONTRACT DOCUMENTS. IF ANY ASPECT OF THE CONSTRUCTION (AS DESCRIBED IN THIS DRAWING SET) ARE UNCLEAR AND IN NEED OF FURTHER DETAILING OR EXPLANATION IN ORDER TO BUILD THIS PROJECT BASED ON THIS DRAWING SET, THE CORRECT PROCEDURE IS FOR THE BUILDER TO SUBMIT A WRITTEN R.F.I. (REQUEST FOR INFORMATION) TO THE ARCHITECT OR ENGINEER FOR CLARIFICATION. AB DESIGN GROUP WILL RESPOND TO ALL WRITTEN RFI's IN WRITTEN/DRAWN FORMS IN A TIMELY MANNER: AB DESIGN GROUP TAKES NO RESPONSIBILITY FOR INTERPRETATIONS OF CONSTRUCTION BY THE BUILDER WHEN NO RFI's HAVE BEEN GENERATED FOR UNCLEAR ASPECTS OF THE CONSTRUCTION BASED ON THE DRAWING SET. lug 1430 CULVER C>RIVe NE, PALM BAY, FL 32907 Tal= (321) 733-7002 Fax: (321) 733-7972 DESIGN CRITERIA: • FBC RESIDENTIAL 6TH EDITION (2017) ABV. A/C • FLORIDA FIRE PREVENTION CODE 6TH EDITION AD.I. • NATIONAL ELECTRICAL CODE (NEC) — 2014 EDITION nnlP. *ALL LOCAL AND STATE CODES BD CL CAB. • OCCUPANCY — RESIDENTIAL, GROUP R3 CLG. • CONSTRUCTION TYPE — VB C COONN C. • MIN. INTERIOR FINISH — CLASS B CPT. • BASIC WIND SPEED — Vult=160 MPH C.r. D. Vasd=124 MPH DBL. -EXPOSURE — C DG PIA. • 1—STORY RESIDENCE — DIM. • 2—STORY RESIDENCE —MAX. HEIGHT AS PER LOCAL DISP. DP. AND STATE CODES DR, D.S. SQ.FT. CALC.'S D.W. I, A, LIVM 1612 SQ. FT. ELEV. QARAGE 432 SQ. FT. EQ. ENTRY 38 SQ. FT. EXH. EXT. LANAI 96 SQ. FT. F.G./FX T.G. TOTAL 2238 SQ. FT. FIN. FUR. A/C VOLUME 14381b CU. FT. FLUOR, FR. DR FTG. GA. GAR. DISP. G.F.I. GL. GYP. BD. H.B. H.C. HDR. HGT. OR HT I.NSUL. INT. LAV. LUM. M.C. ABBREVIATIO S ABOVT, MFR. MANUFACTURER AIR CONDITIONING} MN. MINIMITM ADJUSTABLE M.T. METAL THRESHOLD ALTERNATE MTD. MOUNTED AMPERAGE MTL. METAL, BOARD N.T.S. NOT TO SCALE CENTER LINE O.C. ON CENTER CABINET PL PROPERTY LINE CEILING P.B. PUSH BUTTON CLEAR PH, PHONE CONCRETE, PLT. PLATE CARPET PLYWD. PLYWOOD CERAMIC TILF PR. PAIR DRYER P.T. PRESSURE TREATED DOUBLE R. RISER DUAL GLAZED RAD. RADIUS DI:AMETER R.A.G. RETURN AIR GRILL DIMENSION REP. REFRIGERATOR DISPOSAL RM, ROOM DEEP R.O. ROUGH OPENING DOOR S.C. SOLID CORE EXT DR DOWNSPOUT S.D. SMOKE DETECTOR DETAIL S.H. SINGLE HUNG DISHWASHER SHE. SHEET EACH SHTHG. SHEATHING ELEVATION SHWR. SHOWER EQUAL SIM. S54B.AR EXHAUST SI_ SLIDING EXTERIOR SL. GL. SLIDING GLASS FIXED GLASS STD. STANDARD FUEL GAS SWS SHEAR WALL FINISH SECTION FLOOR TEMP. TEMPERED GLASS FLUORESCENT THK. THICK FRENCH DOOR T.O.C. TOP OF CURB FOOTING T.O.P. TOP OF PLATE GAUGE T.O.S. TOP OF SLAB GARBAGE DISPOSAL TYR TYPICAL GROUNDFAULTU.N.O. UNLESS NOTED CIRCUIT INTERRUPTER OTHERWISE GLASS V.P. VAPOR PROOF GYPSUM BOARD W. WASHER HOSE BIB W/ WITH HOLLOW CORE WD. WOOD HEADER WDW. WINDOW HEIGHT W/H WATER HEATER INSULATION W.I. WROUGHT IRON INTERIOR LAVATORY LUMINOUS MEDICINE CABINET REVISIONS DATE DESCRIPTION 01/08/18 BID SET ISSUED OIA5/18 201-1 FBC UPDATE 01/29/18 BID SET RE -ISSUED 04118AS FOOTING REVISION FIER M. SOWES 02/22/19 PLAN MAINTENANCE 03/28/19 REVISED LINTEL SIZE AT FRONT ENTR7 DOOR 04/24/19 ADDED ADDITIONAL RECEPTACLE IN GARAGE PER WILL BATSON 04/24/19 REVISED HVAC VOLUMES ON SQFT CALC SCHEDULE 06MAS I ADDED LED LIGHTS B KITCHEN t BATHROOMS PER MARK SORES INDEX OF DRAWINGS ARCHITECTURAL SHEET PG CS -COVER SHEET PG GN-GENERAL NOTES PG Al -FLOOR PLAN PG A2C-ELEVATION "C" PG E1-ELECTRICAL PLAN PG P1-PLUMBING PLAN PG D1-DETAILS PG D2-DETAILS PG WAl-WALL ASSEMBLY DETAILS PG WA2-WALL ASSEMBLY DETAILS PG WA3-WALL ASSEMBLY DETAILS PG WA4-NOT USED PG WA5-NOT USED PG WA6-WALL ASSEMBLY DETAILS STRUCTURAL SHEET DESCRIPTION REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY soccer PG S1-FOUNDATION PLAN PG S1.1A-DETAILS PG S1.2-DOWEL PLAN PG S1.2A-DETAILS PG S2-LIFT BEAM PLAN AND NOTES PG S2.1A-DETAILS PG S3-FRAMING PLAN PG S3.1A-DETAILS PG S3.113-DETAILS PG S3.1C-DETAILS PG SN1-DETAILS PG PAI -PRODUCT APPROVALS FILE COPY DESCRIPTION SCANNED BY St. Lucie County 551 S. APOLLO BLVD. MELBOURNE, FL 32901 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 W U O E. C.� 4 F A F ti svaazsv. ee LOT: CREEKSIDE LOT 70 PROJECT 4321.000 070R1 MODEL: 4EAB "1672- ARIA" GARAGE s'VfMG: LEFT PAGE: COVER SHEET 60 MPH EXP. JC ARCHITECT- STATE OF FLORIDA I(WII MCHAEL C. ANDERSON AR NO 17305 rsul'l A 08 5 19 DATE: / / SCALE: 1/4"=1'-0" SHEET c s GENERAL NOTES 1. ALL WORK DONE UNDER THIS CONTRACT SHALL BE IN COMPLIANCE WITH THE FLORIDA BUILDING CODE RESIDENTIAL (FBCR) 6th EDITION, (2017) .AND IN CONJUNCTION WITH ASCE 7-10. ALL REFERENCED CHAPTERS, CODE SECTIONS AND TABLES STATED IN THESE DOCUMENTS ARE UNDER FBCR 6TH EDITION (2017) UNO. 2. WHERE BUILDING LOCATIONS ARE DETERMINED TO BE IN WIND BORNE DEBRIS REGIONS, ALL EXTERIOR BUILDING OPENINGS SUCH AS WINDOWS AND DOORS SHALL BE PROTECTED AGAINST WINDBORNE DEBRIS BY THE INSTALLATION OF STRUCTURAL PANELS OR IMPACT -RESISTANT GLASS. THESE OPENING PROTECTIONS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH CHAPTER 3, SECTION R301.2.1.2. 3. DO NOT SCALE DRAWINGS, THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO WORK PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND, 4. THE CONTRACTOR SHALL BRING ERRORS AND OMISSIONS WHICH MAY OCCUR IN CONTRACT DOCUMENTS TO THE ATTENTION OF THE ARCHITECT IN WRITING AND WRITTEN INSTRUCTIONS SHALL BE OBTAINED BEFORE PROCEEDING WITH THE WORK, THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY ERRORS, DISCREPANCIES OR OMISSIONS IN THE CONTRACT DOCUMENTS, OF WHICH THE CONTRACTOR FAILED TO NOTIFY THE ARCHITECT BEFORE CONSTRUCTION AND/OR FABRICATION OF THE WORK. 5. THE ARCHITECT/ENGINEER SHALL NOT BE RESPONSIBLE FOR THE SAFETY AND CONSTRUCTION PROCEDURES, TECHNIQUES, OR THE FAILURE OF THE BUILDER TO CARRY OUT THE WORK IN ACCORDANCE WITH THE DRAWINGS OR THE REQUIRED CODES, 6. THE STRUCTURAL DESIGN IS BASED ON THE INTERACTION OF ALL PARTS OF THE COMPLETED BUILDING. THE CONTRACTOR SHALL SOLELY BEAR THE RISK FOR PROVIDING ADEQUATE STABILITY AND SAFETY OF THE STRUCTURE DURING CONSTRUCTION UNTIL PERMANENT MEMBERS ARE COMPLETELY INSTALLED. 7, DETAILS SHOWN ON THE DRAWINGS ARE TO BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS. 8. THE CONTRACTOR SHALL MAKE NO STRUCTURAL CHANGES WITHOUT WRITTEN APPROVAL FROM THE ARCHITECT/ENGINEER, 9. NO STRUCTURAL MEMBERS ARE TO BE CUT FOR PIPES, DUCTS, ETC. UNLESS SPECIFICALLY DETAILED. GARAGES AND CARPORTS 1. GARAGE DOOR A. ENGINEERED FOR MIN, WIND LOAD, LISTED ON COVER SHEET B. DETAIL TO BE SUPPLIED BY GARAGE DOOR SUPPLIER C. DETAIL TO BE ATTACHED TO PERMIT PACKAGE BY BUILDER 2. AS PER SECTION R302.5.1: OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING PURPOSES SHALL NOT BE PERMITTED, OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN 1 3/8 INCHES IN THICKNESS, SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN 1-3/8 INCHES THICK, OR 20-MINUTE FIRE -RATED DOORS. 3. AS PER SECTION R302.5.2: DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO, 26 GAGE (0,48 MM) SHEET STEEL 1" MIN. RIGID ON -METALLIC CLASS OR CLASS 1 DUCT BOARD OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE, 4. AS PER SECTION R302.6 & TABLE R302.6: THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT LESS THAN '/2 -INCH GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LESS THAN 5 / 8 -INCH TYPE X GYPSUM BOARD OR EQUIVALENT, WHERE THE SEPARATION IS A FLOOR -CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL ALSO BE PROTECTED BY NOT LESS THAN '/2-INCH GYPSUM BOARD OR EQUIVALENT. SITE WORK 1. REFER TO THE SOILS REPORT FOR SPECIF IC DESIGN REQUIREMENTS (IF REQUIRED BY BUILDING DEPARTMENT), 2. REFER TO THE CIVIL DRAWINGS FOR LOCATION OF BUILDING WORKING POINTS, ROUGH GRADING, ON -SITE UTILITIES, SITE IMPROVEMENTS, SITE RETAINING WA LS, AND SPECIFIC GENERAL NOTES. THE SOILS REPORT AND CIVIL DRAWINGS SHALL OVERRIDE CONFLICTS V lITH SITE WORK NOTED HERERSEE LANDSCAPE DRAWINGS FOR FINAL FINISH GRADES, PLANTING AND IRRIGATIOP 1. 3. ELEVATIONS SHOWN ON THE SITE DRAWIN GS ARE MINIMUM REQUIRED DEPTHS, IF DIFFERENT CONTACT THE ARCHITECT. 4. NO EXCAVATION SHALL BE MADE WHOSE I EPTH BELOW THE FOOTING IS GREATER THAN 1/2 THE HORIZONTAL DISTANCE FROM THE NEAREST EDGE OF TI iE FOOTING. 5. ALL BACKFILL AT STRUCTURES, SLABS, STEPS, AND PAVEMENTS SHALL BE CLEAR OF GRANULAR FILL. PLACE IN 8" LAYERS AND COMPACT TO 95% MAXIMUM MRY DENSITY DETERMINED IN ACCORDANCE WITH ASTM D1557. THE BUILDING SITE SHALL BE KEPT DRY SO TH T EROSION WILL NOT OCCUR IN THE FOUNDATIONS. 6. COMPACTION BY FLOODING OR JETTING ISS STRICTLY PROHIBITED, 7. DO NOT BACKFILL UNTIL SLABS HAVE CUR D OR HAVE BEEN PROPERLY BRACED. (WHERE APPLICABLE) 8. EXCAVATIONS TO BE A MINIMUM OF 3'- 0" EYOND NEW FOOTING LINE, 9. THE GENERAL CONTRACTOR MUST TAKE K EASURES TO CONTROL SOIL EROSION AS PER ALL LOCAL AND STATE REQUIREMENTS. 10. THIS BUILDING IS NOT DESIGNED TO BE CC INSTRUCTED WITHIN A FLOOD ZONE, UNO. CONTRACTOR IS TO VERIFY THE ELEVATION OF THE FINISHED FLOOR SLAE WITH THE SIGNED AND SEALED SURVEY WHICH COMPLIES WITH ALL LOCAL CODES HAVING JURISDICTION, INCLUDING LL APPLICABLE STATE, CITY, AND COUNTY BUILDING AND ZONING CODES, 11. SWIMMING POOL, DECK, SPA, AND ASSOCIATED WORK IS TO BE PERMITTED SEPARATELY BY ENGINEERED SHOP DRAWING, 12. TERMITE PROTECTION SHALL BE PROVIDE BY REGISTERED TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES, BAITING SYSTEMS AND PESTICIDES APPLIE D TO WOOD, OR OTHER APPROVED METHODS OF TERMENT PROTECTION LABELED FOR USE AS A PREVENTATIVE TR ATMENT TO NEW CONSTRUCTION. UPON COMPLETION OF THE APPLICATION OF THE TERMITE PROTECTI TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED EST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: "THE BUILDING HAS RECEIVED A COMPLET TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES, TREATMENT IS IN ACCORDANCE WITH RUL S AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." TIMBER 1. ALL WOODS AND WOOD CONSTRUCTION SHALL COMPLY WITH SPECIFICATIONS AND CODES MODIFICATIONS AS SPECIFIED HEREIN: A. AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (STANDARDS MANUAL) B. NATIONAL FOREST PRODUCTS ASSOCIATION: I. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION C. SOUTHERN PINE INSPECTION BUREAU: I. STANDARD GRADING RULES FOR SOUTHERN PINE LUMBER D. TRUSS PLATE INSTITUTE: I. NATIONAL DESIGN STANDARDS FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES (TPI-2014) E. APA - THE ENGINEERED WOOD ASSOCIATION: I. ENGINEERED WOOD CONSTRUCTION GUIDE F. AMERICAN WOOD PRESERVERS ASSOCIATION STANDARDS 2. ALL LUMBER EXPOSED TO WEATHER, OR AGAINST SOIL, CONCRETE OR MASONRY MUST BE PRESSURE TREATED, 3. MINIMUM NAILING PER CHAPTER 6- WALL CONSTRUCTION AND TYPICAL NAILING SCHEDULE ON PLANS. 4. NOTCHING OR CUTTING OF FRAMING MEMBERS SHALL COMPLY WITH CHAPTER 6- WALL CONSTRUCTION. 5. WALL SHEATHING SHALL BE PER STRUCTURAL, SEE ROOF/WALL/FLOOR SHEATHING FASTENER SCHEDULE ON SHEET SN1. 6. MINIMUM DIMENSION OF ANY PLYWOOD SHEET SHALL BE 24" AND THE MINIMUM AREA SHALL BE 8 FT . SO. PLUMBING 1. SANITARY LINES SHALL BE OF CAST IRON OR PVC (SCHEDULE 40) AS APPROVED BY THE BUILDING OFFICIAL. 2. WATER SUPPLY LINES SHALL BE CPVC OR UPONOR PEX "A" (CROSS -LINKED POLYETHYLENE) WITH F1960 FITTINGS. 3. CONDENSATION LINES SHALL BE MINIMUM'/4" PVC (SCHEDULE 40), INSULATED WITH 1/2" AMAFLEX. 4. SHOWER HEADS SHALL HAVE A FLOW CONTROL DEVICE TO GIVE A MAXIMUM FLOW OF 3 GPM EACH, 5. ALL CLEANOUTS SHALL BE FLUSH WITH GRADE, 6, NO VENT STACKS SHALL PASS THROUGH ROOF CRICKETS, VALLEYS, OR RIDGES, 7. SIZE AND LOCATION OF CLEANOUTS SHALL CONFORM TO SECTION P3005.2. 8. FIXTURE SUPPLY SIZES SHALL CONFORM TO SECTION P2903. 9. THE PLUMBER IS TO DIVERT ALL VENTS TO REAR ELEVATION WHEN POSSIBLE. 10. DRILLING & NOTCHING OF WOOD FRAMED STRUCTURAL MEMBERS SHALL FOLLOW PROVISIONS OF SECTION P2603.2. EXTERIOR WALL COVERINGS 1. ALL EXTERIOR WALL COVERINGS AND SOFFITS SHALL BE CAPABLE OF RESISTING THE DESIGN PRESSURES SPECIFIED FOR THE WALLS FOR COMPONENTS AND CLADDING LOADS IN ACCORDANCE WITH TABLE R301.2(2) AS MODIFIED BY TABLE R301.2(3), MANUFACTURED SOFFITS SHALL BE TESTED AT 1.5 TIMES THE DESIGN PRESSURE EXTERIOR FINISHES 1. WHEN PLASTERING WITH CEMENT, PLASTER SHALL NOT BE LESS THAN THREE COATS, %" THICK, OVER FRAMED WALLS APPLIED OVER PAPER BACKED METAL LATH OR WIRE FABRIC LATH AND WITH TWO LAYERS OF VAPOR BARRIER, NOT LESS THAN 2 COATS, 1/2" THICK, WHERE APPLIED OVER MASONRY OR CONCRETE. 2. STUCCO OR PORTLAND CEMENT PLASTER SHALL BE INSTALLED, PROPORTIONED AND MIXED IN ACCORDANCE WITH ASTM-C926 & ASTM-C1063-12a. 3. LATH & ACCESORIES PER ASTM-C-1 063-1 1A & R703.7.1. ALL STUCCO APPLICATION DETAILS, INCLUDING BUT NOT LIMITED TO: ALL STUCCO CONTROL JOINTS KICK -OUT DETAILS "L" FLASHING HORIZONTAL LATH AND PAPER DETAILS PIPE PENETRATION DETAILS VENT PENETRATION DETAILS WEEP SCREED DETAILS CONDUIT PENETRATION DETAILS CASING BEAD DETAILS DRIP EDGE DETAILS CANTILEVER DRIP EDGE DETAILS CORNER BEAD DETAILS WINDOW CASING DETAILS STUCCO TO SIDING TRANSITION DETAILS WINDOW FLASHING DETAILS 4. SHALL BE INSTALLED PER ASTM-C1063-11AAND R703.7. FIRE RESISTANT CONSTRUCTION UNDER STAIR PROTECTION: 1. ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2" GYPSUM BOARD. R302.7. CONSTRUCTION OBSERVATION CONSTRUCTION OBSERVATION SERVICES / CONSTRUCTION ADMINISTRATION SERVICES ARE NOT A PART OF AB DESIGN GROUP'S SERVICES FOR THIS PROJECT. IT IS UNDERSTOOD AND AGREED THAT AB DESIGN GROUP'S SCOPE OF SERVICES DOES NOT INCLUDE PROJECT OBSERVATION OR REVIEW OF THE BUILDER'S/CONTRACTOR'S PERFORMANCE OR ANY OTHER CONSTRUCTION PHASE SERVICES, AND THAT SUCH SERVICES WILL BE PROVIDED BY THE BUILDER, THE BUILDER ASSUMES ALL RESPONSIBILITY FOR INTERPRETATION OF THE CONTRACT DOCUMENTS, AND FOR CONSTRUCTION OBSERVATION. EXTERIOR CEILINGS 1. EXTERIOR CEILING TO BE 1/2" GOLD BOND BRAND EXTERIOR SOFFIT BOARD INSTALLED PERPENDICULAR TO THE FRAMING MEMBERS. THE 1/2" GOLD BOND BRAND EXTERIOR SOFFIT BOARD IS TO BE SECURED TO THE FRAMING MEMBERS WITH 1 1/4" TYPE "W" DRYWALL SCREWS AT 12" O.C. (PER MANUFACTURER'S SPECIFICATIONS) REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC FILE COPY CONTROL DATE: 07/23/19 (CM) 551 S. APOLLO BLVD. MELBOURNE, FL 32901 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 U w 0 F D3 w C F A SiTBDIV. 8e LOT: CREEKSIDE LOT 70 PROJECT# 4321.000 070R1 MODEL 4EAB "1672- ARIA" GARAGE S WING: LEFT PAGE: GENERAL NOTES 60 MPH EXP. C ARCMTECT. STATE: OF FLORIDA MMAEL C. ANDERSON AR NO 17305 DATE 08/5/19 1 SCALE: 1/4"=1'-0" 1 SHEET GN OOWOMNr AND CLADDM WIND LOADS BASIC WIND EVOSM FOR 3 SECOND GUSTS OPBow AND TYPE SOUAFE FOOTAGE ZONE 180 WH WM M RBMM MIN. WINDOW 10 5 34/-45 CRITERIA EXTERIOR SWING 21 5 32/-42 DR. MIN. CRITERIA S.G.D. MIN. 12 5 30/-31 CRITERIA 8010 O.H.D. 56 5 32.5/-38.0 16010 O.H.D. 112 5 30.9/-34.4 SOFFIT N/A 5 31b/-388 -682S/ IF ROOF TILE N/A 3 -582S APPLICABLE BASIC WIND SPEED MPH = 160 (Vult) INTERNAL PRESSURE COEFFICENT = f 0.18 BLDG. CAT.=II, EXP.=C, MEAN ROOF HT. = 15'-9" PRESSURES HAVE BEEN MODIFIED PER FBCR 6TH ED. (2017) R301.2.1 TO MEET TESTED ALLOWABLE OR NOMINAL WIND LOAD VALUES FROM THE PRODUCT MANUFACTURER. CONpOL DATE 03/20/2 V m oil 12'-0" OND (2) 3052-5H OWNER'S 8'-V CLG. (2) 3052-SH 711 -`r�------------- LANAI DININ� 8 -8 CLG. ROOM I 8'-8' CLG. I I l2J 3052-SH I 6'-6" 3'-10" 3'-4" i G. JIR Ti.�0. 9 ¢x. �I I GREAT ROOM �� W-8' CLG. ---�� O ° ° �— C•V.� ,� -- Ba. CLG KITCHE >A3' 0" 3'-10" i3'-0" 11 3'-9" 3' 8" " 4'-4" 41' 1 Q uu._� i 1- I J N I 2X6 - -- I 0. BATH 3-sH j�4i�C�j `^ BDRMA3 8'-8' CL& LAv. S'-8' CLG. ® il I il I LL----J � _4 LAY. iiif 1 -, Al vlI 36'x60' ii u� i SHWR PAN 3-SW wH. LA . 1R=15H 8'-8' CILG. I ATTIC I I I 1 a BATH #2 L —4CCE56L J B l y e W-8' CLG. VII Al V j2d)-t' Av. VBOLLARD r all , AS REQ. PER BLDG. v C I I IR-1SH CODE`- V. — — DYER s GARAGE -8' CLG.; 8'-S' CLG. � 3068 W 3'-5 2'-4' 6' 8° � 36'XI2" NS. F� . _--_ - F .T. HB BDRM.#2 6 8'-8' CLCx NTRY (2) 3052-5H 16 -0 X7 -0 O.HD. EGRESS - - - - - - - - - - - - - - - F. ARCH 2' 4'_4 '_01 2'-61 S 6 8'-4" 11 u EXTERIOR MASONRY WALL BRCS. HEIGHTS I-1 8'-8' BRCrt. DBL. TOP PLATE SQ.FT. CALC S LIVING GARAGE ENTRY LANAI 1612 432 38 96 SQ. FT. SQ. FT. SQ. FT. SQ. FT. TOTAL 2238 SQ. FT. A/C VOLUME 14381.6 CU. FT. I BAR DETAIL A SCALE: BAR ARCH ITL. B SCALE: I/2 1'-0' REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC FILE COPY FLOOR PLAN SCALE: 1/4' NOTE- -2-8 LOUV. DOOR W/ AIR HANDLER ON METAL ,STAND OR 2-8 SOLID DOOR W/ RETURN PLENUM AND RETURN AIR GRILLE. - VERIFY CONDENSER PAD LOCATION WITH SITE PLAN. -OTHER OPENINGS 5ETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH 50LID WOOD DOORS NOT LESS THAN 1 3/8' (35 MM) IN THICKNESS, SOLID OR HONEYCOMB -GORE STEEL DOORS NOT LESS THAN 1 3/8' (35 MM) THICK, OR 20-MINUTE FIRE-RATI=D DOORS. S. APOLLO BLVD, MELBOURNE, FL 32901 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 W w 0 F G �1 Q ti a 64 ti SVBDIV. 8e LOT: CREEKSIDE LOT 70 PROJECT# 4321.000 070R1 MODEL 4EAB "1672-ARIA" GARAGE STING: LEFT PAGE: FLOOR PLAN 60 MPH EXP. C ARCH'11=C STATE OF FLORID MICHAEL C. ANDERSON AR NO 17305 PRINT 08 5 19 DATE: / / SCALE: 1/4"=1'- 0" SHEET Al BLDG. HGT.$ 1�6 4' RAISED SAND 0p OPT. COACH LIGHT g � A 0'-0" FIN. FLR- ^ �1 VM I if TILES A� FJDL%,ONT ELEVATION SCALE: 1/4 = I'-0' TEXTURED FINISH NOTE: WALL FENESTRATION FLASHING AS PER FSCR R-I03.4 8'-8" BRCS, HGT. 1'-0" 4B A Tom. II 0'-0" FIN. FLR. . 8'-8" BRCn. I-IC�T. 0'-0" FIN. FL OFF RIDGE VENT 1�6 I-ICsT. 8_8" Bi2Cs. I-ICsT. BRCS. H4GT. 1'-0 -0" FNi FLR. 0'-0" FIN. FLR. OFF RIDGE VENT 1�6 REAR ELEVATION SCALE: 1/4 = 1'-0' TEXTURED FINISH ---------------s------------- i--------------------- --- LEFT EL VATION SCALE: 1/4 = 1'-0' TEXTURED FINISH I OFF RIDGE VENT OFF RIDGE RIGHT ELEVATIION 8'-8" BRG. H4GT. Il_o" I 415 A li {,0' FIN. FLR- BRCi- HGT. BRCY. HGT. 48 TYP. II _ Y01_0" FIN. FLiR. REVIEWED FOR I CODE COMPLIANCE \ 8' ST. LUCIE COUNTY - BOCC DECO. DETAIL �0'-0" FIN. FLR. FILE COPY MODEL 1672-ARIA AREA OF ATTIC = 2318 SQ. FT. NET FREE VENTILATION AREA REQUIRED 1/ 300 REQUIRED VENTILATION AREA = 2318 /300 = 7.73 SQ. FT. 7-73 = 1112.64 SQ. IN. MIN. REQUIRED VENTILATION IN = AX 1112.64 UPPER PORTION OF ATTIC = 445.056 SQ. IN. (BALANCETO BE PROVIDED IN SOFFITVENTS) OFF RIDGE VENTILATION AREA = 138 SQ. IN. PER VENT(netfree area) TOTA{ #OFVENTS REQUIRED = 3.23 TOTAL#OFVENTSPROVIDED = 4 sOFFITVENTP:A'TION AREA 7 SQ. IN. PER LINEAR FT (net free area) LINEAR FEET OF SOFFITREQUIREC 63.58 551 S. APOLLO BLVD. MELBOURNE, FL 32901 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F hW 0 4 I SVBDIV. 8e LOT: CREEKSIDE LOT 70 PROJECT# 4321.000 070R1 MODEL: 4EAB "1672—ARIA" GARAGE SWING: LEFT PAGE: ELEVATION "C" tt,160 MPH EXP. C mmmmmommoor ARCHITECT STATE OF FLORIDA r21���� MICHAEL C. ANDERSON AR NO 17305 D TE 08/5/19 SCALE: 1/4"- l' — 0" SHEET A2 C s . ELECTRICAL LEGEND SYMBOL DEFINITION NOTES - e 125V OUTLET 20 AMP SINGLE POLE 110V OUTLET 110V OUTLET T/! OF OUTLET WIRED TO SWITCH GFI 110V OUTLET EOWPED WK~ FAUL INTERUPTER (TAMPER RESISTANT TYPE) 220V OUTLET (4) WIRE CON'IECTION F T GFI OUTLET IINTERRUPTERGROUND SWITCH SWITCH 3-WAY OPE . t�4 SWITCH 4-WAY OPER t�i� WALL MOIPITED I� LIGHT CEILING LIGHT O LED CLG LIGHT O VP VAPOR PROOF LIGHT ORECESSED CAN WALL SCONCE PRE -WIRED eVENT. FAN I OEM PER sa FT. VENT. FAN W/LIGHT I CFM PER Sd FT. YAFIIT LraHT FIXTURE (SPEC'S TTSD BY IXIILDEIV MSCENT FLUORE WRAP ® LIGHT AROUND ADD (RECESSED) ® 41X2' FLUORESCENT LIGHT 2-BULB WRAP AROUND (SURFACE MNT.) T FLUORESCENT W FLUORESCENT p p�� AAa E 4' TRACK LIGHT m PANEL OWN METER OSMOKE SD. DETECTOR BAIT. BACK-UL" ul/ HARDWIRE WALL MOUNTED BATT. BACK-UP_ SU7. SMOKE DETECTOR W/ HARDWIRE ® S/CO CARBON MONOXIDE,HARDWIRC BMOCE DETECTOR BATT BACK-T IP V INTER -CONNECTED SHALL BE A DISTANCE COMBD OF NOT LESS THEN 4' FROM WALL PENDANT LIGHT L� fl/ NATURAL GAS OUTLET ` TELEPHONE JACK WATER HEATER TO BE ELEVATTE2 DISCONNECT AIR CONDITIONING DISCONNECT TV TELEVISION JACK CEILNG BOX;SMIRE OJ-BOX TO BE SUPPORTED N AC 01il GE W/ BOX MARKED AS SUCH FOR CTION CEILING BOX N 70 15E SUPPORTEDlIN CEILING FAN/LIi ACCORDANCE W/ BOX MARKED AS SUCH FOR INSPECTION AnA•Q 24' INCANDESCENT LIGHT STRIP nno 36' INCANDESCENT LIGHT STRIP nnnnnnnn 0 48' INCANDESCENT LIGHT STRIP FLOOD LIGHT oPT. SECURITY KEYPAD HE P.B. PUSH-BUTTON FOR CHIMES ��► Ue6 Poor • LOCATION OF TV JACKS 4 PHONE OUTLETS 4 FANS TO BE VERIFIED • HOMEOWNER Pam -CONSTRUCTION MEETING. • ALL 15 4 20 AMP BRANCH CIRCUITS TO ME ARC FAULT PROTECTED PER ELECTRICAL PROVISIONS OF FMCR 6TH EDITION (2011) 4 NEC 210.12 2014 EDITION. • 20 AMP DEDICATED LAUNDRY CIRCUIT. • GPI a ISLAND (NOT ON KITCHEN CIRCUIT) • DISHWASHER DISCONNECT TO BE LOCKOUT IN PANEL • BATHROOM EXHAUST FAN TO HAVE MN. CAPACITY OF 50 CFM INTERMITTENT PER ELECTRICAL PROVISIONS OF SECTION M15013 FBCR 6TH EDITION (2011). • LAUNDRY ROOM RECEPTACLE SHALL BE GROUND FAULT CIRCUIT -INTERRUPTER PROTECTION FOR SONNEL ON FMDRS • WIR HOD SHALL BE NON METALLIC CABLE PER ELECTRICAL PROVISIONS OF FBCR 6TH ED (2011). • ALL WORK TO COMPLY WITH ELECTRICAL PROVISIONS OF THE FBCR ETA ED (201V • ALL LAMPS SHALL BE SELECTED BY BUILDER AND 1516 OF LIGHTING MUST BE ENERGY EFFICIENT TYPE PAR F5, ENERGY CNWRVATION (RESIDENTIAL ENERGY EFFICIENCY) 2011. 6th EDITION R404.1 METER FIELD VERIFY LOC. ---------- - I PRE -WIRED CEILING CLG FANL. MTO. LIGHT OWNER'S I TO BE SUITE INSTALLED, PROVIDE I J-BOX FOR OPT. FAN \\ s®o DINING PRE -WIRED �� ROOM �lv CLG FAN HOOD WIRE W/ OUTLET FOR S.D. / FUTURE MICRO. Q _, / GFI Lr ;�\ L EIS GPI• a + I1 �( PRE -WIRED SWITCH IN W.I.C. \1 —¢ I CABINET ,�� T CLG FAN \ KITCHEN / � GREAT ROOM Z I ( — AGFI 0. _-BATH IL BDRM.#4,11 �\ A- F1� \ GFI LAiCJ LAUN. a / PRE -WIRED 0 CLG FAN ]I � G42' GFI �j • - I ;� i� ------ C WH "�';o,�.F. �44 AFF, r �PAB. FORGARAG I r —'� DOOR E j BATH #�j I I 1 BOLLARD AS REQ. WALL MOUNTEDPER COPE BLDG. LIGHT W/SWITCH IN ,/ L ATTIC y i KEYLESS S/C FIXTURE FOYERI I 1w GFI \ \ Q CLG. O S.D. IL OUTLET i �\ BDRM.#2 IRRIGATION I D r [ \ OUTLET a /F.P.---FOR 48' Ai / I � C; c GFI GARAGE �� j PRE -WIRED CLG FAN - ENTRY OPT. COACH _� ������ LIGHT ---------- ELECTRICAL PLAN SCALE: 1/4' = I'-0' LED LIGHTING WP Panel MAIN - A PANEL: 6116wp crt. breaker VOLTAGE: 12D7240V-1Ph MAIN: 150 Amp M.C.B FEEDER'.3-#1 Cu THWN&1-#6Cu(G)m111 C. OR 3-#2f0ALTHAN&1-#6Cu(G)in11/ C. Description I watts I Circuit 1 1 circuit 1 Wales 1 Description #v t �n r.-y,l.odb sr ,-[Ti = I 1 . , I #t: ? �n;nnl' mn Fii�nu PANEL - A PANEL: 42 crt. bri V OLTAGE: 1201240 V -1 Ph MAIN: 150 Amp M.L.O. FEEDER. 3 #1 Cu THWN & 1- #6 Cu (G) in 1 12" C. OR 3- #210 AL THM & 1- #6 Cu (G) in 1 12" C. Wire Pole Skr Description Warts Circuit Circuit watts Description Bkr Pole Wire 6 12 1 J omall Ap111a oe 'I ';u 8000 Nanye bu 2 48 #t2 1 ,n mill-, -. Iluu.l"1 1. nn a - #1i 1 '0 '•.=,p:ais1°" 00 451.0 'N:dar '.al ei 25 J *10 #7' 1 10 R-tit, l I 1 8 012 0Ii 01_' 1114 1 1 1 1 'u it A, rininu1 eva-leeAFC _ ks r rt _ J1rot l r Lanai T in: L 9ri:s _ u 1200 'I A, 9 .. 18 I : '': _ In )u 1"Cu tn0 L.1sal°F" LI a herBFl _ DryerGFl 21) 2u 4V 1 _ 1 2 02 #11 #10 v 8 1500 W-'c"'GrI PO #tt #14 1 --TA (j J 41-1 n 19 ll 00 t rauor ,i . Poneri FI ,0 1 *12 #1: 1 0 1 r- I sRecepl les GFl 20 'I #12 _ 1 1 e_ s 1 _ b00 u0!I " c:-e ut6AFCl _ Vwnafs e lo%= AF 'I _ C a it 1 ndRe, 11GF1 ♦rev. -t n 11 15 16 211 , 1 1 , #14 111Li I'll 10 SlN GLE LAV . ® BATH 02 — A AH I Load 5u4ec:o dema d Is", :dlUel Demi Factor Ca Iati< r a1 Ibie:tt dnn:'mb;r I 1 .rtF v i5l I ntalnina watt= at F . n .ota: L a::.:-.ts I_ I � 1 I I I I a I I I I � I LED LIGHTING C60 DOUBLE LAV. OWNER'S BATH 150 AMP ELECTRICAL RISER NOT TO SCALE. GENERAL NOTES: A. ELECTRICAL MATERIALS AND INSTALLATIONS SHALL COMPLY WITH ELECTRICAL PROVISIONS OF THE MCR 6tH EDITION (2011 LOCAL CODES, AND ALL LOCAL POWER COMPANY REQUIREMENTS. B. ALL CONDUCTORS SHALL BE TYPE THHN/THWN UNLESS NOTED OTHERWISE. POWER COMPANY TRANSFORMER GRADE PROVIDE 150 AMP, 120/240 VOLT, I PHASE SECONDARY ELECTRICAL SERVICE. PROVIDE 3 01 COPPER (CU) IN 1-1/2" DIA SCHEDULE 80 PVC CONDUIT OR PROVIDE 3 *2/0 ALUMINUM (AL) IN 2" DIA SCHEDULE 80 Pi CONDUIT UNLESS SERVICE 15 PROVIDED BY THE ELECTRIC COMPANY. COORDINATE WITH THE ELECTRIC COMPANY PRIOR TO BID. 5120 A v=c- hna rv'e ,uL Load SLtr:ttO Clenloni kCtnr oalaulahunsll Una '!'!I ABBREVIATIONS: AFCI: ARC FN Ur CRCLIR NTERRUPTER NC: NONCONCDFNTLOAD 24U GFI: GR.;+UND FAULT INTERPUP TER woo LOAD CALCULATION IS SASED ON A/C NON -COINCIDENT LOAD in ra. L:s e I 5016 Hl- 1ts _ 1 M 6ow/Light at 100%_ _ 65 ' t - n a L t �.' att=� I An., REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC FILE COPY PROVIDE 302/0 CU, THWN + 1% CU IN 2' CONDUIT OR 3 04/0 AL, THU N + 1% CU IN 2' CONDUIT. (CONDUIT TO TERMINATE ABOVE SOFFIT • OVERHANCs.) COMBINATION SERVICE 150 AMP DISCONNECT SWITCH AND 120/240 VOLT M ELECTRIC METER IN I PHASE NEMA 3R ENCLOSURE MLO PANEL 150A/2P MCB TELEPHONE SERVICE ENTRANCE EQUIPMENT INTERSYSTEM BONDING TERMINAL AT LOW VOLTAGE CONNECTIONS GABLE TELEVISION SERVICE ENTRANCE EQUIPMENT 1 #4 CU SERVICE GROUND CONNECTED TO CONCRETE ENCASED FOOTER STEEL PER ELECTRICAL PROVISIONS OF THE FBCR 6tH EDITION (201.1). 5/8" DIA X 8 FT LONG COPPER CLAD GROUND ROD 551 S. APOLLO BLVD. MELBOURNE, FL 32901 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 rQ W jai V In In yF R 03 Q E A V [SUBDIV. 8g LOT: CREEKSIDE LOT 70 PROJECT: 4321.000 070R1 MODEL: 4EAB "1672—ARIA" GARAGE SUING: LEFT PAGE: ELECTRICAL PLAN 60 MPH EXP. C ARCH(i STATE OF FLORIDA V �v MICHAEL C. ANDERSON AR NO 17305 PRINT ]DATE: 08/5/19 SCALE: 1/4"=1' — 0" SHEET El lio 0 0 L- m N a F — - it +I- PLUMBING PLAN SCALE: 1/4 = P-0' 0 2'-g" 2'-9" a KITCPEN SINK W/ AUTO VENT 2' V.T.R JIB 2 2, I I/2 ,1 11/2' i I 1 1/2° i 11/2' , �,I - 2 2 1 1/2' --- �1 E/2' I i REVIEWED FOR CODE COMPLIANCE S T . LUCIE COUNTY BOCC FILE COPY 2' V.T.R J!� 2 � 11/2'� 1 1/2'->�' I / / I �1 1/2' r 21 I TUE3 I 3, TO 3' MAIN 4' PLUMBING RISER DIAGRAM 551 S. APOLLO BLVD. MELBOURNE, FL 32901 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F V W O y� U Gl W 4 F A ti IF tMDIV. 8e LOT:CREEKSIDE LOT 70 ROJECT# 4321.000 070R1 ODEL: 4EAB "1672—ARIA" GARAGE SWING: LEFT PAGE: PLUMBING PLAN 60 MPH EXP. C so ARCHITECT. STATE OF FLOM el�lcl-� MICHAEL C. ANDERSON AR NO T7305 NP ATTE: 08/5/19 ALE: 1 /4"=1' - 0" SHEET 1 F W y U Z F 4 D3 4 � c A 0 FF sysDIV. 8e LOT: CREEKSIDE LOT 70 PROJECT 4321.000 070R1 MODEL: 4EAB "1672-ARIA" GARAGE SWING: LEFT PAGE: H VAC PLAN 160 MPH EXP. C rrcaan-a 08 5 1 DATE: 9 SCALE: 1/4"=1' - 0" SHEET 1/2' CLG. DRYWALL SURE BT. — ATE TO SLAB 10d MASONRY IL s 32' O.G. -0' d. FLR. nvw CI At= 1SS 2X4 WOOD STUDS 624' O.C. SLAB NU I >_- 0 1 ULJS IN PARTITIONS SUPPORTING WALL HUNG PLUMBING FIXTURES AND WALL CABINETS SHALL BE NOT LESS THAN 2x4, WHERE SPACED NOT MORE THAN lb" O.G. OR, NOT LESS THAN 2x6, WHERE SPACED NOT MORE THAN 24" O.G. TYP. INT. WALL (NON— BRG. SCALE: 3/4' = I'-C' FIBERGLASS SHINGLES OVER 030 FELT PAPER OR SYNTHETIC PRODUCT, INSTALLED PER SECTION R905.1.1 ON in OS$. SHEATHING OR J' CDX PLYWOOD SECURED PER FASTENER SCHEDULE PRE-ENG TRUSS MTL. DRIP EDGE 2x FASCIA PER77Y 11 11 ELEVATIONS VENTED SOFFIT 1/2' THICK, 2 COAT PORTLAND- CEMENT PLASTER APPLIED DIRECTLY TO MASONRY 0'-0' FIN. FL 5/8' GYPSUM BOARD ; OR 1/2' HIGH STRENGTH CLG. BOARD PER ELEVATION1-7 _ SEE ENERGY CODE FORMS INSULATION R-VALUES REFERENCE STRUCTURAL PER ELEVATION J _ - - — R-4.1 INSULATION WINDOW ATTACHMENT SPECIFICATIONS PER MANUFACTURES SPEGIFIGATIONS REFERENCE STRUCTURAL 1x2 P.T. FURRING STRIPS 0 24' O.C. S' CMU 1/2' GYP. WL. BD- WOOD BASE I FIBERGLASS SHINGLES OVER 030 FELT PAPER OR SYNTHETIC PRODUCT, INSTALLED PER SECTION R905.1.1 ON O.S.B_ SHEATHING OR COX PLYWOOD SECURED PER FASTENER SCHEDULE STRUCTURAL PRE-ENG TRUSS MTL. DRIP EDGE 2x FASCIA PER ELEVATIONS VENTED SOFFIT 1/2' THICK, 2 COAT PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY 0'-0' FIN. FLR I ti W/ WINDOW OPENING B TYP. WALL SECTION NO OPENING NOTE: PER SECTION c305.1.1 - FOR ROOF SLOPES 2:12 TO LESS THAN 4:12, A (-5�1—STORY HIP BLOCK WALL (2) LAYER UNDERLAYMENT SYSTEM SCALE: 3/4' = I' -O' IS REQUIRED. FOR ROOF SLOPES OF 4:12 OR C3REATER, (I) LAYER UNDERLAYMENT IS PERMITTED BUT MUST BE PER ASTM D226 TYPE II, ,45TM D 486S TYPE IV, OR ASTM D 6151 CAUuc AND SEAL GAS LINE i' PVC SLEEVE FOR GAS LINE a Cm tog GYP. U - BD. -WOOD DASE 2 GAS LINE THRU BLOCK D1 SCALE: v.'.r_o FIBERGLASS SHINGLES OVER 030 FELT PAPER OR SYNTHETIC PRODUCT, INSTALLED PER SECTION R905.1.1 ON �j' O.S.B. SHEATHING OR is CDX PLYWOOD SECURED PER FASTENER SCHEDULE MTL. DRIP EDGE jj" 2x FASCIA PER ELEVATIONS I VENTED SOFFIT J PRE-ENG. GABLE TRUSS WEEP SCREED 2x P.T. SECURED PER STRUCTURAL DETAILS 1/2' THICK, 2 COAT—L--- PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY 0'-0" FIN. FLR, S' CMU 1/1' THICI(, 7 COAT - PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY GALV.STEEL` TRACK BRACKETS FASTENED TO WOOD JAMB PER PRODUCT GALV. STEEL APPROVAL REa VERTICAL TRACK 1' MIN. BY MAUF. SLIDE FASTENED TO ROOM TRACK BRACKETS W/PRODUCT APPROVAL REQ. COINER BEAD a' CHU SEE STRUCTURAL FOR REINFORCEMENT 2x& P.T. WD ATTACHED TO FILL CELL AS PER PRODUCT APPROVAL REa. SEALANT BACKER ROD USATHER STRIP MOULDING ALL AROUND (BY DOOR MANUF.) OVERHEAD DOOR BY OTHERS GARAGE DOOR JAMBS SCALE: 1 1/2"= V -0" 2x BLOCKING BETWEEN TRUSSES PER STRUCTURAL DETAILS --- STIFFBACK AT ALL UPRIGHTS i PER STRUCTURAL DETAILS I -m PRE-ENG Wp. TRUSS TYF'. O.N. PER ELEVATION 7 CONT. 2x RAT RUN SECURED PER STRUCTURAL DETAILS SEE ENERCsY CODE FORMS FOR — INSULATION R-VALUES PER ELEVATION 5/8' GYPSUM BOARD OR 1/2' TRENGTH CLG. BOARD A W WINDOW OPENING R-4.1 INSULATION WINDOW ATTACHMENT AS PER MANUFACTURES SPECIFICATIONS REFERENCE STRUCTURAL lx2 P.T. FURRING STRIPS o 24' O.G. 1/2' GYP. WL. BD. WOOD BASE FIBERGLASS SHINGLES OVER 030 FELT PAPER OR SYNTHETIC PRODUCT, INSTALLED PER SECTION R905.1.1 ON �,' O.S.B. SHEATHING OR J' COX PLYWOOD SECURED PER 0, FASTENER SCHEDULE TYP. MTL. DRIP EDGE O.N. 2x FASCIA PER ELEVATIONS VENTED SOFFIT PRE-ENG. GABLE TRUSS WEEP SCREED 2x P.T. SECURED PER STRUCTURAL DETAILS n TYP. WALL SECTION No OPENING 1—STORY GABLE BLOCK WALL SCALE: 3/4' = I'-O' 1/2' THICK, 2 COAT PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY CMu 0'-0' FIN. FLR REVIEWED Fc)R CODE CCMp-LjANC ST. LUCIIE COUNT' R0CC FILE 'COP' RECETVEg NOV 01 2019 ST_Lucie county, Perm 551 S. APOLLO BLVD. MELBOURNE, FL 32901 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 W vi 914 w o a a� U w � q w F M A 9 ti SVBDIV. 8e LOT: CREEKSIDE LOT 70 PROJECT# 4321.000 070R1 MODEL: 4EAB "1672—ARIA" GARAGE SWING: LEFT PAGE: DETAILS 60 MPH EXP. C 00 ARCHrmcT: STATE OF FLORIDA OCT "17 2di MIC HAEL O. ANDERSON AR NO 17305 DATE 08/5/19 1 SCALE: 1/4"=10-0" SHEET SECURE 2x6 MIN. W/ 2'X2'Xlb WASH# GARAGE DOOR I 0 L LI C] I ELK W/ (2),151W A -BOLTS 4' EMBEDMENT MIN. AND NUT SPACED EVENLY FROM FLOOR IN JOINTS PRIOR TO FILLIksp- I 'SECURE 2x4 ON 1 FLAT TO BLK W/ CUT NAILS. SIDES: 2X6 GARAGE DOOR BUCK W/ (5) VXS' A -BOLTS 4' EMBEDMENT MIN W/ 21X2'XIk WASHER AND NUT SPACED EVENLY FROM FLOOR TO GARAGE DOOR PDR. IN JOINTS PRIOR TO FILLING. 1-2X6 PT BLOCK • CENTER OF DOOR HEADER W/n))vx8' J-BOLTS 4' EMBEDMENT W/ 2'X2'XK' WASHER AND NUT. ALL ANCWORS SHALL BE IN ACGOFlDANCE TO MANUFACTURER'S NSTALLATION INSTRUCTIONS WHET SUCH INSTRUCTIONS AID MORE STRINGENT GARAGE DOOR BUCK ATTACHMENT D SCALE: VJ'•I'-®' 8' CMU ii' DRYWALL 1'X4' OR I'X2' P.T. NAILER ❑ lx4 P.T. OR b/4'X4' MIN. SECURE THRU FRAME 4 EXTEND 1-Y4' INTO BLOCK ❑W/ %(6' TAPCONS F(MIN- SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT I-Y4' WITHIN 8' OF EACH END 4 18' O.G. MAX SPACING \`DOOR CASING DOOR JAMB OR WINDOW ATTACH TO 2X PER MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED Y41) DOOR JAMB TO BLACK +3/4 OR +5/4 (WINDOW TO BLOCK +3/4 OR +5/4 " SCALE: N.TS. 2X4: SECURE TO BLOCK W/ 3f5 TAPCONS OR (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT I Y4') WITHIN 8' OF EACH END 4 IS' O.G. MAX SPACING. 2X6:® SECURE TO BLOCK W/2-%- TAPCONS(MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT I Y4') — WITHIN 8' OF EACH END 4 IS' O.G. MAX SPACING. 2X&:cm SECURE TO BLOCK W/2-n6' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT I Y4') WITHIN 8' OF EACH ENDY 18' O.G. MAX SPACING. 8' CMU ❑" DRYWALL I'X4' OR I'X2' P.T. NAILER r-DOOR CASING DOOR JAMB OR WINDOW ATTACH TO 2X PER MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED Y4') DOOR JAMB TO BLOCK +1-1/2" WINDOW TO BLOCK +1-1/2" " SCALE: N.TS. 2X4= SECURE TO BLOCK W/ TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 Y4') WITHIN 8' OF EACH END 4 18" O.G. MAX SPACING. NOTE: STRUCTURAL 2X 2X6>� MUST BE ON OUTSIDE 4 SECURED THROUGH SECURE TO BLOCK W/2-3i{ti TAPCONS NON-STRUCTURAL,' (MIN. SHANK SIZE TAPCON MIN. I-Y4' .145 MIN. HEAD SIZE .300 EMBEDMENT INTO BLOCK. MIN. EMBEDMENT I Ya') 8' CMU )�' DRYWALL WITHIN 8' OF EACH END 4 18' O.G. MAX SPACING. 1'X4' OR 11X2' P.T. NAILER 2X8:® ❑ SECURE TO BLOCK W/2-){6' -X" O.S.B. X 4' MIN. TAPCONS (MIN. SHANK SIZE .145 DOOR CASING MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 Y4') DOOR JAMB OR WINDOW WITHIN 8' OF EACH END ; ATTACH TO 2X PER 15' O.C. MAX SPACING. MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED V4') DOOR JAMB TO BLOCK +1-15//16" i1 WINDOW TO BLACK 4" SCALE: N.TS. 2X4:® SECURE TO BLOCK W/ Wb, TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE .300 MIN. EMBEDMENT 1 Y41) WITHIN 8' OF EACH END 4 NOTE: STRUCTURAL 2X 18' O.G. MAX SPACING. MUST BE ON OUTSIDE 4 2X6am SECURED THROUGH SECURE TO BLOCK W/2--Xg NON-STRUCTURAL ' TAPCONS TAPCON MIN. 144' (MIN. SHANK SIZE .145 EMBEDMENT INTO BLOCK. MIN. HEAD SIZE 300 MIN. EMBEDMENT I Y4') WITHIN 8" OF EACH END 4 8' CMU 18' O.C. MAX SPACING. DRYWALL 2X8 ❑' I'X4' OR I'X2' P.T. NAILER SECURE TO BLOCK W/2-1(6' DOOR CASING: TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 DOOR JAMB OR WINDOW MIN. EMBEDMENT I Y4') ATTACH TO 2X PER WITHIN 8" OF EACH END 4 MANUFACTURES DETAILS. V O.G. MAX SPACING. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED Ya') DOOR JAMB TO BLOCK +2 1�4' �— WINDOW TO BLACK +2 1/V �" JSCALE: N.TS. 2X4= SECURE TO BLOCK W/ Ws' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT I Y4') WITHIN 8' OF EACH END 4 NOTE: STRUCTURAL 2X 18' O.G. MAX SPACING. MUST BE ON OUTSIDE 4 2X6cm SECURED THROUGH SECURE TO BLOCK Ul/2_W..NON -STRUCTURAL W%' TAPCONS TAPCON MIN. 1-Y4' (MIN. SHANK SIZE .145 EMBEDMENT INTO BLOCK MIN HEAD SI ZE 300 8' CMU MIN. EMBEDMENT 1 Y4') V DRYWALL WITHIN 8' OF EACH END 4 18' O.G. MAX SPACING. I'X4' OR I'X2' P.T. NAILER ❑2X8 SECURE TO BLOCK W/2-W6' TAPGONS DOOR CASING (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 Y4') DOOR JAMB OR WINDOW WITHIN 8" OF EACH END 4 ATTACH TO 2X PER 18' O.C. MAX SPACING. MANUFACTURES DETAILS. NOTE: SWIM AS NEEDED TO Mlrft JAMS, = NOT EXCEED X.) DOOR JAMB TO BLOCK +3" WINDOW TO BLOCK +3- 'ALE SCALE: N.T.S. 2X4= SECURE TO BLOCK W/ �16' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT I V4') WITHIN 8' OF EACH END 4 NOTE: STRUCTURAL 2X IS' O.G. MAX SPACING. MUST BE ON OUTSIDE 4 2X6:® SECURED THROUGH SECURE TO BLOCK W/2-%' NON-STRUCTURAL 3{e TAPCONS(MIN. SHANK SIZE TAPCON MIN. I-Y4" .145 EMBEDMENT INTO BLOCK. MIN. HEAD SIZE 300 MIN. EMBEDMENT I Y49 WITHIN 8' OF EACH END 4 8' CMU 18' O.C. MAX SPACING. %(t° DRYWALL 2X8:® ❑ -I'X4' OR I'X2" P.T. NAILER SECURE TO BLOCK W/2-%- - 2ND 2X SECURE TO TAPGONS(MIN. SHANK SIZE STRUCTURAL MEMBER .145 W/(2)l2d WITHIN 8' OF EACH MIN. HEAD SIZE 300 6 END 4 ' TO 8' O.G. MAX MIN. EMBEDMENT I Y4') DOOR CASING WITHIN 8" OF EACH END 4 DOOR JAMB OR WINDOW 18' O.C. MAX SPACING. -ATTACH TO 2X PER MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED Y4') DOOR JAMB TO BLACK +T WINDOW TO BLACK +T SCALE: N.TS. 2X4cm SECURE TO BLOCK W/Y4' TAPCONS(MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT I Y4') NOTE: STRUCTURAL 2X WITHIN 8' OF EACH END 4 MUST BE ON OUTSIDE 4 18' O.G. MAX SPACING. SECURED THROUGH 2X6:® NON-STRUCTURAL 3/(6" SECURE TO BLOCK W/1-1/4' TAPCON MIN. I-Y4' TAPCONS(MIN. SHANK SIZE EMBEDMENT INTO BLOCK. .145 MIN. HEAD SIZE 300 8" GMU MIN. EMBEDMENT I Y4') 8 DRYWALL WITHIN 8' OF EACH END 4 18' O.G. MAX SPACING. ❑ I'X4' OR I'X2' P.T. NAILEREVIEWED FOR 2X8 CODE COMPLIANCE SECURE TO BLOCK W/1-1/4' X6' OSB. X 4' MIN. TAPGONS ST. LUCIE COUNTY (MIN. SHANK SIZE .145 DOOR CASING BOCC MIN. HEAD SIZE 300 MIN. EMBEDMENT i Y4') DOOR JAMB OR WINDOW WITHIN 8' OF EACH END 4 ATTACH TO 2X PER IS' O.G. MAX SPACING. MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMP JAMS, (DO NOT EXCEED Y,') DOOR JAMB TO BLOCK +3-7/16" %r1 WINDOW TO BLOCK +3-7/16" " SCALE: N.TS. 2X4= SECURE TO BLOCK W/)/4- TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 Y4') ENE) WITHIN 8' OF EACH E4 NOTE: STRUCTURAL 2X 18" O.C. MAX SPACING. MUST BE ON OUTSIDE 4 2X6:® SECURED THROUGH SECURE TO BLOCK W/1-1/4' NON-STRUCTURAL 3(6° TAPCONS TAPCON MIN. 1-Y4' (MIN. SHANK SIZE .145 EMBEDMENT INTO BLOCK. MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 Y4') -8' CMU WITHIN 8' OF EACH END 4 }�' DRYWALL O.C. MAX SPACING. ❑ I'X4' OR I'X2' P.T. NAILER 2X8» ' SECURE TO BLOCK W/1:JiTTACH ' P.T. X 4' MIN. TAPCONS OOR CASING (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 Y4') WITHIN 8' OF EACH END DOOR JAMB OR WINDOW IS° O.G. MAX SPACING. TO 2X PER MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED Y4 ) DOOR JAMB TO 13LDCK +3 3/4" %r1 WINDOW TO BLOCK +3 3/4" ,, SCALE: N.T.S. FILE COPY 551 S. APOLLO BLVD. MELBOURNE, FL 32901 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F W h U W Dl- F U W C F A SLT7B3DIV. 8e LOT: CREEKSIDE LOT 70 PROJECT* 4321.000 070R1 MODET : 4EAB "1672-ARIA" GARAGE SWING: LEFT PAGE: DETAILS 60 MPH EXP. ARCHITECT- STATE OF FLORIDA MICHAEL C. ANDERSON AR NO 17305 08/5/19 I SCALE: 1,/4"=1'-0" 1 SHEET 0 REVIEWED FOR O1. FOLD IN"ND • IM A O 1. FOLD INWARD • PT. A CODE COMPLIANCE 2. CREAN * Fr. 0 KIC KO UT ST. LUCIE COUNTY ® DETAIL BOCC FOLD .,b. ® 1/16' ZIP SHEATHING SYSTEM (INSTALLED PER MANUF. SPECS.) OR OL FOLD nNIuARP • O 1. F04-D ,,,,,,,,,, V . PT. A - WOOD SHEATHING OR CMU Pr. A :. CREAM • It. B WR5 LAYER 01, 7. CREASE • Pr. ° s. cIFAeE • Pr. c STUCCO WRAP (FRAME ONLY) FILE COPY 9. CREASE • Pf. C 4. FOLD Pr. C OVER M. B TILL PT. C TOUCFES °OTTOM FLANGE ® pI THICK, 3 COAT CEMENT PLASTER (FRAME), 1/2" 2 COAT CEMENT PLASTER (CMU)76 EGEN METAL LATH (FRAME ONLY) Lij ® ®�D ® LAP WR5 4 TAPE OVER DRAINAGE f=LANE (UJR5 • m. BOTTOM ROOF/WALL SCREED FLANGE ARWnw-rr LA1I� fR#1, STUCCO WRAf=) NOTE: SEAl.- FOLD, Ma elina,T. IF ZIP SHEATHING SYSTEM 15 INSTALLED,PLEA5E SEE PTRITER3COATCEMENT 5AL 'L' TYPE CONTINUOUS WR5 ,�A, rER � ifORTIf15ER — — — — — PLASTER PLASTER (U, 1/2' s soar GALV. METAL FLASHING r /� MANUFACTURERS CtM L,°CASTER FO Z (NAIL TO ROOF DECK, NOT 5U I L D INCB 'AFE R) INSTALLATION PROCEDURES U1R0 LAYER 4, FORTIPfBER �n � BUILDING PAPER aW E ONLY) WALL SHEATHING) U1RB LAYER M, CAP SHINGLE - DO NOT NAIL, 1" IETAL LATH X X X X STUCCO aWRAP (PRN-E ONLY) INSTALL WITH ROOF CEMENT ' 4\'i: •i� �" �' LAP LAYERS OF BUILDING WUP 4,i, ? OVER NAILING FLANGE, STOP fJ e�;i'.~i„s USE AFFRPX Ili' ABOVE BSTUCCO BUNGLES (FRAI'E ONLY/ p, - - PRAM OR CM .•KGB•• EXTERIOR \ a �I ROOF CEMENT _ - u1oLL FLASHMG c ROOF PER ELEVATIONS WOOD SHEATHING o %— /OR 7/16' ZIP SHEATHING SYSTEM ' c P �'LOIU1i FLASI-ZING (NM b, t�1 S � L � ` I!~t a../ �f E V 1 Y E 1— L A S I� NG � — NOTE: IF ZIP SHEATHING SYSTEM IS NOTE: INSTALLED, PLEASE SEE MANUFACTURERS 1IETAL LATH: LATH TO BE FER SECTION FELTUNDERLAYMENT y� INSTALLATION PROCEDURES — WATER TIGER SEAL (BEND OR BOLDER. DO NOT GIUTU R1O3.-I.1 / ,4ST1�I C-8��'-O9, 1�'IN, 2.5 LDS. dQ¢� INSTALL KICKOUT SHINGLE RDOFMG 8R0 ING AT]JAI 11 �IONOM 6 OF ROOF 4 i# DRIP ED: OYEIRLAP 9', 1=ER ea. `rARD (UTILITNr, OR N01�-IINAL E)REJD 1/2' BF10IU 0 EAT44M MECHANICALLY FASCIA WRAP L T DOES NOT 1"I T S C I I C,� T I ON S) !FASTEN 4'°`-MAX c� " L" FLASHING 0 N.T.S. 5515. APOLLO BLVD, MELBOURNE, FL 32901 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 W W 0 F U y W O F A SL7BDIV. 8e LOT: CREEKSIDE LOT 70 PROJECT# 4321.000 070R1 MODEL: 4EAB "1672-ARIA" GARAGE SWING: LEFT PAGE: WALL ASSEMBLY DETAILS 60 MPH EXP. C ARCHrrECT- STATE OF FLORIDA / " MICHAEL C. ANDERSON AR NO T 3305 Dpp 08/5/19 SCALE: 1/4"-1'-0" )4i_i;: STUCCO FINISH L' SELF ADHESIVE OVER TOP 4 SIDES 'I/16' ZIP SHEATHING SYSTEM SELF INSTALLED PER MANUF. SPECS.) OR FLASHING WOOD SHEATHING WRB LAYER *I, UNIT STUCCO WRAP PREMANUF. DRYER WRE LAYER "2, FORTIFIBER _ VENT CAP (SET IN BUILDING PAPER CONT. SEALANT) METAL LATH WOOD T/e' TEXTURED Ii FINISH OOD CONSTRUCTION SEALANT g FASTEN TO WOOD STRUCTURAL TOP 4 SIDES MEMBER • l' Or, MAX a' crn.t � i �' Ye' TO 1i' MID -WALL WEEP SCREED �B DRYER VENT (BLOCK) _ Z� Za J 6' WIDE STRIP SELF ADHESIVE FLASHING, CLEAN MASONRY BEFORE APPLYING - — — BUILDING PAPER TEXTURED OVER FINISH • MASONRY FLASH' QUICK B HORIZONTAL WEEP SCREED FLASH' r — — — � � � FRAME TO BLO C K� PIPE THROUGH WALL NOTE: IF ZIP SHEATHING SYSTEM IS INSTALLED P LEAS E SEE MANUFACTURERS 6' SELF ADHESIVE INSTALLATION PROCEDURES FLASHING: (INSTALL PER MANUF. SPECS.) BUILDING PAPER all UNDER 'QUICK FLASH' NOTE: WRB LAYER 01, ► IF ZIP SHEATHING SYSTEM IS CUT OPENING IN STUCCO WRAP INSTALLED, PLEASE SEE APPROVED HOUSEWRAP MANUFACTURERS FOR BOX INSTALLATION Au INSTALLATION PROCEDURES CUT "XI INTO A VENT PENETRATION RB LAYER "1, SELF -ADHERING \x REVIEWED FOR SCALE: N.TS. STUCCO WRAP MEMBRANE FLASHING DE COMPLIANCE APPLY SELF -ADHERING: • LUCIE COUNTY WOOD SHEATHING MEMBRANE FLASHING: BOCC I OVER BOX AND OVER APPROVED WRB LAYER _ - S T F #1 e T � #2 FILE COPY - APPROVED - HOUSEWRAP — BELOW WRB LAYER *I, ELEC. METER 'FIELD 1 stucco WRAP VERIFY LOCATIONELEC. METER FIELD VERIFY LOCATION CUT SUCH THAT APPLY 60 MIN SELF -ADHERING: NO MEMBRANE GRADE 'D' FELT MEMBRANE FLASHING: ENTERS BOX, OVER APPLY STUCCO SCRATCH COAT AF LY TO FACE SELF -ADHERING: a E AND ON (1) FLASHING E A NGs o LAYER OF PAINT VER PRIOR TO INSTALLING ELEC. APROVED i METER HOUSEWRAP WRB LAYER 02, FORTIFIBER • CAVITY TO BE FILLED .BUILDING PAPER WITH RIGID POLYMERIC 5TEF #3 LEGEND- ISOCYANOTE-POLYBLEND FOAM _ ('GREAT STUFF" OR SIMILAR) DRAINAGE PLANE (WR5 APPLY A SILICON ELASTOMERIC BASE SEALANT AT POINT COATING: OVER LAYER #1, STUCCO WRAP) THAT ELEC. WIRE PENETRATES STUCCO/ C.V. FINISH APPLY E-Z BEAD .,,,,,,, o�A (SEE TYPICAL WALL WRB LAYER 02 (FORTIFIBER - - - - _ OVER 60 MIN b•e-�� sEcTlow BUILDING PAPER) AREA TO RECEIVE . STUCCO SCRATCH COAT FELT -PROVIDE « METAL LATH 00 SEALANT AT ALL o' a� METAL LATH X—X—x—X 4 1 COAT OF PAINT W/BACK- SEALANT JOINTS AND o� ROLL PRIOR t0 INTERSECTION: ;° "�.a a.Q.`s�. STUCCO _� EC. METER INSTALLATION ,� �_PROVfIDE STUCCO SCRATCH COAT LARGER THAN THE ELEG. WOOD SHEATHING _ METER CAN OR METER CAN OR TALL ZIP SHEATHING SYSTEM COMBO OR METER CAN AND (INSTALLED PER MANUF. SPECS) SELF-ADHESIVE FLASHING - - DISCONNECT NOTE: 5TEF #E� 5TEF #(o METAL LATH: LATH TO BE PER SECTION ELECTRICAL RECEPTACLE R-fm3.7.i / ASTM c-S4-f-m�J, MIN. 2.5 LESS. � ELECTRICAL CONDUIT PENETRATION PER SQ. YARD (UTILITY OR NOMINAL LATH DOES NOT MEET SPECIFICATIONS) 551 S. APOLLO BLVD. MELBOURNE, FL 32901 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 W W O F U A r a mmmmmmmmmm CREEKSIDE LOT 70 4321.000/070R1 WODEL: 4EAB "1672—ARIA" wAlRAGE SWING: LEFT PAGE: WALL ASSEMBLY DETAILS 60 MPH EXP. ARCHITECT STATE OF FLORIDA MICHAEL C. ANDERSON AR NO 17305 ?EtINT 08 5 19 DATE: / / SCALE: 1/4"=1' - 0 " SHEET WA2 EJ LGEN-T DRAINAGE PLANE (I.URB LA4rER #1, STUCCO UJRAP) WRB LATER *2 (FORT11=I5ER - - - - - BUILDING PAPER) METAL LATH x x x x STUCCO - UJOOD SHEATHING OR XIP SHEATHINGSYSTEM (INSTALLED PER MANLIF. SpEcS. ) REVIEWED FOR SELF-ADHESIVE 1=LASHING — — — CODE COMPLIANCE ST• LUCIE COUNTY Bocc FILE COPY 2 1/2 BEAD (I=ASTENER 4 5PACING I" O.C.) cv L47CORNER (V —CMu V THICK, 3 COAT CEMENT PLASTER APPLIED DIRECTLY TO MASONRY 14B CORNER BEAD @) BLOCK 551 S. APOLLO BLVD. MELBOURNE, FL 32901 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 W U W O F U r W 4 F A F ti CREEKSIDE LOT 70 4321.000/070R1 MODEL: 4EAB "1672-ARIA" GARAGE SWING: LEFT PAGE: WALL ASSEMBLY DETAILS [60 MPH EXP. ARCHrrECT- STATE OF FLORIDA MICHAEL C. ANDERSON AR NO 17305 ram"&' ` OS 5 19 DATE: / SCALE: 1/4"=l'-0" SHEET Zh`A3 WOOD CONSTRUCTION BEYOND WOOD SHEATHING WEATHER RESISTIVE BARRIER 7 WEATHER RESISTIVE — BARRIER •1 X 1 Ya' LAP SIDING /6' REVEAL 6' SELF -ADHERING — FLASHING STARTER GALV'D METAL ' FLASHING im 6' SELF -ADHERING FLASHINGs I I d WEATHER RESISTIVE \ BARRIER 01 / \ \ WEATHER RESISTIVE \ / BARRIER 02 6' SELF -ADHERING FLASHING \ GALV'D METAL \ i T FLASHING DO NOT CAULK OR __ SEAL OPENING I Yi X 6' SIMULATED WOOD TRIM MEMBER SEAL GAP W/GAULKING / OR APPROVED SEALANT SIDING TO STUCCO Ca? BLOCK TO FRAME TRANSITION NOTE: METAL LATH: LATH TO BE PER SECTION R103.1.1 / ASTM C-84-1-09, MIN. 2.5 L88. PER SQ. YARD (UTILITY OR NOMINAL LATH DOES NOT MEET SPECIFICATIONS) REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC FILE COPY LEGS D DRAINAGE PLANE (WR5 LAYER 01, STUCCO WRAP) WRB LAYER 02 (FORTIF15ER — — — — BUILDING PAPER) METAL LATH x—x—x—x STUCCO 1 WOOD SHEATHING OR 1/16' ZIP SHEATHING SYSTEM (INSTALLED PER MANUF. SPECS.) SELF-ADHESIVE FLASHING — — 551 S. APOLLO BLVD. MELBOURNE, FL 32901 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F N U3 V W O F 0. U h 4 F A StMDIV. & LOT: CREEKSIDE LOT 70 PROJECT 4321.000 070R1 MODEL 4EAB "1672-ARIA" GARAGE SWING: LEFT PAGE: WALL ASSEMBLY DETAILS 60 MPH EXP. C ARCHIT STATE OF FLORIDA 9161�`c MICHAEL C. ANDERSON AR NO 17305 DATE: 08/5/19 SCALE: 1/4"=l'-0" SHEET 2x6 SUS -BAND W/1 "x4" NOTCH a END, WRAPPED PEEL 4 STICK DRIP EDGE 1/8" TEXTURED FINISH -a WOOD 1/2" TEXTURED FINISH e CMU METAL FASCIA WRAP YS' FROM STUCCO, I" FROM WOOD WALL \ i EXTERIOR WALL (FRAME OR CMU �\\ NOTE: NOTCH FOR 2Xrio SUS BAND ONLY �\ I ( )ELEVATION - 1/8' TEXTURED FINISH o WOOD, 1/2' TEXTURED FINISH a CMU I `—METAL LATH IN METAL FASCIA WRAP WOOD SHEATHING ' OR CMU Iv i r WR5 LAYER *1, 1 STUCCO WRAP (FRAME ONLY) 1 = WRE5 LAYER "2, FORTIFI5ER ........ \ WILDING PAPER (FRAME ONLY) i 1 - I \` 2X(o SU5 BAND ROOFING CEMENT I ` / \ / 1 DRIP EDGE 1 METAL KICK OUT 1 1 1 ROOF KICK OUT REMOVED 1` FOR CLARITY \ ROOF DECK (BEYOND) DRIP EDGE, 1" OFF WALL NOT INTO STUCCO) 11/8" TEXTURED FINISH / WOOD, 1/2' TEXTURED FINISH a CMU 2xro SUB -BAND W/1"x4" NOTCH a 1'7 END, WRAPPED IN PEEL 4 STICK METAL FASCIA WRAP 1" OFF WOOD WALL. SUB BAND 2" OFF WOOD WALL NOTE: IF ZIP SHEATHING PLEASE SEE M4 PRE-ENG'D TRUSS TO BE CUT 6 WALL LINE TO AVOID CONTACT W/TEXTURED FINISH 2 "x4 "x4' - O' SCABBED TO TRUSS W/126 NAILS 61-8" O.G. MAX. 2x SUS -BAND W/lY"x4" NOTCH a END METAL FASCIA WRAP DRIP EDGE EXTERIOR WALL 'FRAME OR CMU) SUB BAND DETAIL @ WALL SUB BAND DETAIL ® WALL W/KICK-OUT FRAME OR CMU FELT PAPER DRIP EDGE (REFERENCE POINT ONLY, FOR WALL OFF SET OF COMPONENTS) METAL FLASHING, WRAPPED MIN. Y4" ABOVE BOTTOM OF DRIP EDGE 2x SUB -BAND JJ/lY "x4" NOTCH a END, WRAPPED IN PEEL 4 STICK ,ROOF CEMENT a ROOF EDGE OMITTED FOR CLARITY REVIEWED FOR CODE COMPLIANCE CE ST. LUCIE CGU Bocc FILE COPY FRAME OR CMU WALL KICK -OUT FLASHING FELT PAPER DRIP EDGE (REFERENCE POINT ONLY, FOR WALL OFF SET OF COMPONENTS) -lETAL FLASHING, WRAPPED '11N. Y4" ABOVE BOTTOM OF DRIP EDGE 2x SUB -BAND tJ/1Yx4" NOTCH a =ND, WRAPPED IN FEEL e STICK ROOF CEMENT a ROOF EDGE OMITTED FOR CLARITY 551 S. APOLLO BLVD. MELBOURNE, FL 32901 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 ti w U w 0 F w Q q sVBDIV. 8a LOT: CREEKSIDE LOT 70 PROJECT# 4321.000 070R1 MODLE 4EAB "1672-ARIA" WI GARAGE SNG: LEFT PAGE: WALL ASSEMBLY DETAILS: SUB -BAND 60 MPH EXP. I ARCHrrECT- STATE OF FLORIDA MICHAEL C. ANDERS0N AR NO 17305 DATE: ` 08 5 19 SCALE: 1 /4" =1' - 0" SKEET WA6 FOUNDATION NOTES 1. SEE SLAB SCHEDULE FOR SLAB REQUIREMENTS. SEE GENERAL NOTES FOR COMPACTING REQUIREMENTS. 2. TOP OF FINISHED SLAB SHALL BE+-0'-0". 3. COLUMN AND FOOTING CENTERLINES, SHALL COINCIDE UNLESS DIMENSIONED OTHERWISE. 4. REFERENCE ELEVATION +44% SEE SURVEY PLOT FOR NGVD. 5. PROVIDE A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT SHOULD BE IN ACCORDANCE WITH THE RULES AND LAWS AS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES. 6. PROVIDE ISOLATION JOINTS BETWEEN INTERIOR AND EXTERIOR SLABS ON GRADE: PROVIDE 1/2" FELT PAPER AT THE JOINT. 7. COORDINATE SLAB ELEVATIONS, STEPS, AND SLOPES WITH ARCHITECTURAL DRAWINGS. 8. SEE ARCHITECTURAL DRAWINGS FOR THE ORIENTATION OF THE BUILDING. 9. WINDOWS, DOORS AND ROUGH OPENINGS ARE TO BE COORDINATED WITH THE WINDOW/DOOR TYPES AND LOCATIONS NOTED ON THE ARCHITECTURAL DRAWINGS AND WITH THE MANUFACTURES SPECIFICATIONS, 10. SEE ARCHITECTURAL DRAWINGS FOR WALKWAY SLAB LAYOUT. 11.1INDICATED #5 BAR, EIINDICATES #6 BAR,OINDICATES #7 BAR VERTICAL REINFORCING BAR IN CELLS FILLED WITH GROUT. ENDS OF REINF. BARS SHALL BE HOOKED INTO FOUNDATION BOND BEAM OR TIE BEAMS WITH AN ACI STANDARD 900 HOOK. BARS SHALL BE PLACED AS SHOWN IN HE PLANS. 12. SPLICES IN REINFORCING BARS SHALL NOT BE LESS THEN 48 BAR DIAMETERS (#5 = 30", #6 =36"), AND REINFORCING SHALL BE CONTINUOUS. 13. RATIONAL ANALYSIS WAS PERFORMED TO DETERMINE SIZE AND STEEL REINFORCING FOR ALL FOUNDATIONS. DESIGNED WAS BASED ON ALL ALLOWABLE SOIL BEARING CAPACITY OF 2,000 PSF. TRANSFER REINFORCING (TOP STEEL) HAS BEEN DELETED UNLESS NOTED OTHERWISE, 14. VERTICAL REINFORCING IN CMU SHALL BE #5'S AS SHOWN ON THIS PLAN, UNLESS OTHERWISE NOTED IN THE PLAN. ONE REINFORCING BAR SHALL BE: A) IN ALL WALL INTERSECTIONS B) CHANGES IN ELEVATION C) EACH SIDE OF ALL OPENINGS D) ALL CORNERS 15. STRUCTURAL DESIGN IS IN ACCORDANCE WITH A.C.I.530-13/ASCE 5-13, BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES AND THE COMMENTARY. CONSTRUCTION SHALL BE IN ACCORDANCE WITH A.C.1.530.13/ASCE 5-13, USING: F'm = 1,500 PSI, TYPE "M" OR"S" MORTAR, ASTM C476 GROUT (3000 PSI), UNITS LAID IN RUNNING BOND. 16. WIRE WELDED MESH LOCATED IN THE MIDDLE TO UPPER s OF SLAB SUPPORTED 3'-0" O/C MAX. SEE PLAN FOR WWM SIZE. INSPECTOR NOTE: 1. STRUCTURE WAS DESIGNED BASED ON THE 2017 FLORIDA RESIDENTIAL BUILDING CODE, RESIDENTIAL, 6th EDITION SLAB SCHEDULE SLAB THICKNESS REINF. REMARKS 8x6 W1.4XW1.4OVER GENERAL 3 1/2" 6 MIL VAPOR COMPACTED FILL BARRIER FOOTING SCHEDULE PROVIDE CORNER BARS, SAME SIZE QUANTITY AS BARS IN FOUNDATION WITH 30" LEG EACH WAYWREINF.TOP MARKMWIDTHJLENGTHTTHICKNESS. TOP REINF. T.O.GFM-12x185's FMC-12x18's #5 IN CURB VARIES F-24x24's FM-12x12's TE-1's H0'-0" REVIEWED FUR CODE COMPLI A ^ ST. LUCIE C UFI-v'&'Y BOCC FILE COPY FOUNDATION PLAN SCALE: 1/4" = 1'-O" 551 S. APOLLO BLVD. MELBOURNE, FL 32901 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 ti W U W 0 h 4 rl w O A ti SLTBDIV. k LOT: CREEKSIDE LOT 70 PROJECT# 4321.000 070R1 MODEL: 4EAB "1672-ARIA" GARAGE SWING: LEFT PAGE: FOUNDATION PLAN 60 MPH EXP. C ARCHR'ECT- STATE OF FLORIDA MICHAEL C. ANDERSON AR NO 17305 OB/5/19 I SCALE: 1/4"=1'—O" 1 SHEET s l 30" MIN. EACH WAY MONOLITHIC FOOTING STEEL REINFORCING IN GROUTED - --' - STEEL REINFORCING GROUTED r CELL SEE PLAN FOR SIZE AND Q CELL SEE PLAN FOR SIZE AND �1 SPACING REQUIREMENTS } I SPACING REQUIREMENTS _I = r `'�_— GARAGE DOOR F m Q Il w I I w RECESS O7U va aC �� �FM <D a p 00 a 8" CMU WALL - CORNER BARS, SAME SIZE AS BAR w mw 8" aC e7 - z — $" CMU WALL z - I I IN FOUNDATION WITH 30" LEG EACH W U O -- M m — — +- 0'-0" _ WAY AT ALL CHANGES IN DIRECTIONS cA Co TOP OF SLAB TOP OF SLAB I ) SO THAT THE STEEL REINF. IS CONTINUOUS x MATCH AMOUNT OF CONTINUOUS BARS CURB FOR MASONRY J VARIES I L N f SEE SLAB SCHEDULE I (" UNITS SET EXT. PORCH SLAB 4" CHAMFER (1-STORY) W/ 1/2" ISOLATION 6" CHAMFER (2-STORY) JOINT (WHERE • • APPLICABLE) z SEE SCHEDULE FOR WxD, BAR SIZE IN AND BAR QUANTITY BAR SIZE 48 BAR DIA. #3 18" #4 24" #5 30" #6 36" #7 42" SEE SLAB SCHEDULE TOP OF GARAGE o CONTINUOUS STEEL MONOLITHIC EXT. PORCH SLAB 4" CHAMFER (1-STORY) FOOTING REINFORCEMENT SEE SCHEDULE T Q„ OATOELEV: W/ 1/2" ISOLATION 6" CHAMFER (2-STORY) JOINT (WHERE • • SEE SCHEDULE WHEN TRANSITIONS ARE MADE FROM FOUNDATIONS HAVING APPLICABLE) Z FOR WxD, BAR SIZE DIFFERENT NUMBER OF CONTINUOUS BARS PROVIDE THE LEAST AND BAR QUANTITY NUMBER OF BARS (ie. 2 TO 3, PROVIDE 2 BARS), UNO CV MONOLITHIC FOUNDATION RECESS AROUND GARAGE EXTERIOR MONO -FOOTING IOR MONOFOOTING 1 )EXTER- 2 CORNER BARS DETAIL DOOR OPENING SCALE:3/4"=V-0" GARAGE SCALE:3/4"=1'-0" 3 SCALE: 3/4"=1'-0" SCALE: 3/4"=1'-0" Lu I 2" CAPPED j co NEW REINF. BAR GALVANIZED PIPE O a SECURED W/ 2- PART W/FLANGE @ BASE p� I EPDXY. MIN. EMBED o Q 8", LINO Q p FOLLOW ALL MANF. m I SPECIFICATIONS FOR Q USE AND SECURE FLANGE TO H 00 PREPARATION OF v 4„ 411 SLAB W/(4) 1/4" X 2 1/4" HOLE. Z lcxc TAPCONS Jco o �¢Q `7 PEVIEWED FOR CAE COMPLIANCE 4" CHAMFER (1-STORY) 6" CHAMFER (2-STORY) m LUCIE COUNTY " BOCC BOLLARD ADDING BAR TO 5 SCALE:3/4"=1'-0" MONOLITHIC FOUNDATION FILE COPY 6 SCALE: 3/4"=1'-0" STEEL REINFORCING IN GROUTED CELL SEE PLAN FOR SIZE AND SPACING REQUIREMENTS z �I ¢EL -I o} aW m V 0 J p 8" CMU WALL _ Z POURED LINTEL CONT. (TYP.) - +- 0'-0" a,, 8" CMU FILLED CELL (TYP.) TOP OF SLAB zo 2X WAIL FRAMING SEE SLAB SCHEDULE 1/2" DIA. USP 7250SD BOLTS 5" Z ? MINIMUM EMBEDMENT INTO "ISOLATED" COLUMN PAD GROUTED CELL, 4" FROM ENDS AND CENTERED UNDER WALL AND 16" O-C. VERTICALLY MAX co —� POURED MONOLITHICALLY WITH r — — — — — — FOUNDATION AND SLAB SEE SCHEDULE • r • FOR WxD, BAR SIZE AND BAR QUANTITY COMBINED EXTERIOR MONO- INTERIOR FRAME BRG WALL TO FOOTING AND COL. PAD BLOCK WALL CONNECTION 10 11 SCALE:3/4"=1'-0" SCALE:3/4"=1'-0" 551 S. APOLLO BLVD. MELBOURNE, FL 32901 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 y U W O F V W 4 F A F ti SVBDIV. 8e LOT: CREEKSIDE LOT 70 PROJECT# 4321.000 070R1 MODEL: 4EAB "1672-ARIA" GARAGE SVFMG: LEFT PAGE: DETAILS 60 MPH EXP. ARCHrrECT- STATE OF FLORDA WCHAEL C. ANDERSON AR NO T7305 rxs4jm a 195 DATE: 08 / / SCALE: 1/4"=1'-0" SHEET Slot L I VAI 001 Anil DOWEL PLAN SCALE: 1/4" = V-0" REVIEWED FOR )DE COMPUANCE -JT. LME COUNTY Bocc 91 iA 551 S. APOLLO BLVD. MELBOURNE, FL 32901 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F W U W 0 R U W 4 F A Cv ti SUBDIV. 8e LOT: CREEKSIDE LOT '70 PROJECT# 4321.000 070R1 MODEI.a 4EAB "1672-ARIA" GARAGE SWING: LEFT PAGE: DOWEL PLAN L60 MPH EXP. C ARCHfTECT- STATE OF FLORIDA MICHAEL C. ANDERSON AR NO 17305 DATE: 08/,i/19 I SCALE:1/4"==1'-0" SHEET si. TIE VERTICAL REBAR TO HORIZONTAL REBAR W/ 10" HOOK GROUTED BOND BEAM VARIES PER ELEV. T — #5 BARS T FEI � -- 0 CLEAN OUT REQUIRED FOR INSPECTION 1 -0 m Ir co- — O I �� a I 0'-0" FIN. FLR. 1'-0" TIE ERTICAL REBAR TO HORIZONTAL = REBAR W/ 10" HOOK _Z LLJ U • CMU UNIT DIMENSIONS ARE NOMINAL SIZES �/y` r� MASONRY SYMBOLS HORIZONTAUVERTICAL 3 SCALE:3/4"=v-o,, 1 REINFORCING SCALE: 3/4"=1'-0" REVIEWED FOR 'DDE COMPLIANCE . LUCIE COUNTY BOCC FILE COPY BAR SIZE 148 BAR DIA. #3 18" #4 24" #5 30" #6 36" #7 42" 551 S. APOLLO BLVD. MELBOURNE, FL 32901 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F U rA 0 F y 4 A ti SUBDIV. 8a LOT: CREEKSIDE LOT 70 PROJECT# 4321.000 070R1 MODEL: 4EAB "1672-ARIA" GARAGE SWING: LEFT PAGE: DETAILS 60 MPH EXP. C ARCHITECT= STATE OF FLORIDA i WCHAEL C. ANDERSON AR NO 17305 DATE 08/5/19 SCALE: 1/4"=1' — 0" SHEET S1• 2A FRAMING NOTES: 1. U.N.O. ALL STRAPS FOR ROOF TRUSSES TO BE CONCRETE TO WOOD ROOF: USP HTA16 W/ (9) 1 Od x 1 1/2" HDG NAILS. CONCRETE TO WOOD FLOOR: USP LPTA W/ (10) 10d x 1 1/2" HDG NAILS, WOOD TO WOOD: USP RT16A OR LUGT2 W/ 1 Od x 1 1/2" HDG NAILS, FILL ALL HOLES, 2. ALL PLYWOOD FOR WALL AND ROOF SHEATHING IS TO BE PER FASTENER SCHEDULE. 3. ALL PLYWOOD FOR FLOOR SHEATHING SHALL BE PER FASTER SCHEDULE MEETING THE REQUIREMENTS OF AFG-01 AND APPLIED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 4. ALL NAILS FOR TRUSS TO BEAM AND TRUSS TO TRUSS METAL CONNECTORS ARE TO MATCH CONNECTOR FINISH. 5. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON LINTEL MANUFACTURER SHOWN IN STRUCTURAL PLANS. 6. BOTTOM OF LINTELS ARE TO BE PLACED AT TOP OF WINDOW, DOOR AND CLEAR SPAN OPENINGS. 7. LINTELS SHALL HAVE 4" NOMINAL BEARING (4"). 8. THE TRUSS FRAMING SHOWN IS SCHEMATIC IN NATURE. HOWEVER THE SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRUSS DESIGNERS LAYOUT. SUBMIT FINAL TRUSS DRAWINGS FOR THE ENGINEER'S REVIEW AND APPROVAL. 9. PLACE 2x4 PT TO ALIGN WITH TOP AND BOTTOM CHORDS OF ROOF TRUSSES SECURE 2x MEMBERS TO WALL WITH HILTI X-ZF, POWDER ACCTUATED FASTENER, ZF 72 P8S36, .177" ° x 2 7/8" LONG, WITH WASHER r7a 16" O.C. 10. TRUSS REACTIONS AND UPLIFTS SHOWN ARE THE SAME ON EACH END UNLESS OTHERWISE SHOWN DIFFERENT. 11. WOOD BEARING WALLS AND HEADERS HAVE BEEN DESIGNED BASED ON RATIONAL ANALYSIS. 12. ALL ELEVATIONS ARE REFERENCED FFIOM U-0", FINISH FLOOR. UNLESS NOTED OTHERWISE. HEADER SCHEDULE MARK SIZE S DESCRIPTION REMARK 1D (2) 2X8 BEAM SCHEDULE INDICATES OPENING BELOW / T.O.B. = TOP OF BEAM / B.O.L. = BOTTOM OF LINTEL/T.O.A. = TOP OF ARCH /T.O.S = TOP OF SLAB ABBREVIATIONS E.E. = EACH END, O/C = ON CENTER, F.E.S. = FROM EACH SUPPORT, T.O. = THROUGHOUT MARK DESCRIPTION f'c (psi) SIZE W'xH' REINFORCEMENT STIRRUPS REMARKS BTM. TOP MID SIZE SPACING BB1 MASONRY 3000 8x8 — (1) #5 — NIA — GROUTED SOLID "CAST-CRETE" SAFE LOAD TABLES SAFE GRAVITY LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS SAFE LATERAL 8" PRECAST & PRESTRESSED LOADS FOR U-LINTELS SAFE UPLIFT LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS �4m" SAFE LOAD POUNDS PER LINEAR FOOT 40~74m r SAFE P TOAD C_._-/►m" --1---- 1�11► SAFE LOAD - POUNDS PER LINEAR FOOT TYPE LENGTH sU8 8F8-08 BF12178 SF76-0B BF20.06 BF24-OB BF28-0B BF32-08 TYPE LENGTH Sus 8F6 RCMu LENGTH TYPE 8F8-1T BF12-iT 3F16-1T BF20.1T BF24-1T BF281T 8F32-1T 8F8-1B BF12-1B 8Fi6-18 BF20-1B BF24.16 8F28-18 8F32-18 BF8-2T 8F12-2T 8F16.2T BF20.2T 8F24-2T BF28-2T 8F32-2T T-6" 42" PRECAST ( ) 2231 3069 3719 5163 6607 8054 9502 10951 T-6" (42") PRECAST 1025 1024 1598 T-6" (42") PRECAST 1569 2655 3524 4394 5263 6132 7001 3069 4605 6113 7547 8974 10394 11809 lssa 2655 3524 4394 5263 6132 7001 4'-0" 48" PRECAST ( ) 1966 2581 2751 3820 4690 5961 7034 8107 4'-0" (48") PRECAST 765 763 1309 4'-0" (48") PRECAST 1363 2305 3060 3815 4570 5325 $079 2693 4005 6113 7547 e974 0394 t18o9 1363 2305 3060 3815 4570 5325 6079 4'-6" (54") PRECAST 1599 7969 2110 2931 3753 4576 5400 6224 4'-6" (54") PRECAST 592 591 1073 4'-6" (54") PRECAST zo7 z0ao 2707 3375 4ag3 g711 s37s 2189 4375 6113 7547 p) 8672 10294 11809 1207 2040 2707 3375 4043 4711 5379 5'4" (64") PRECAST 1217 1349 1438 1999 2560 3123 3686 4249 5'4" (64") PRECAST 411 411 745 5'4" (64") PRECAST 1016 171$„) 227614, 2838 3399 3961 4522 1663 3090 5365 7547(35) 7342„9) 873311.1 10127p9) 1016 1715 2276 2838 3399 3961 4522 5'-10" (70") PRECAST 1062 1105 1773 1631 2090 2549 3009 3470 5'-1D" (70") PRECAST 340 339 616 5'-10" (70") PRECAST 909 1567(,e) 208Q13) 2593 �� 3107,l 3620,°) 4133(s) 145t 2622 4360 7168,°5) 6036„9) 7181pe) 8328 ��, 929 1567 2060 2593 3107 3620 4133 6'-6" (78") PRECAST 908 1238 2177 3480 3031 3707 4383 5061 6'-6" (78') PRECAST 507 721 490 6'-6" 78" PRECAST ( ) 835„zl t407rz9) 16sljzu 232s," 27sgs) 3251,a1 3712nz; 1238 2177 3480 5381 8360 10394s7) 8825„4, 835 7407 1868 2329 2790 3251 3712 T-6" (90") PRECAST 743 1011 1729 2661 2698 3191 3885 7'-6" (90") PRECAST 424 534 363 T-6" (91 PRECAST 727 �z31 106 s) 7624,3p 2025ia, 2426(2n) 2827,251 3228124) 1017 1729 2661 3898 3696 5681 8467,w) 6472„51 727 1224 1624 2025 2426 2827 3228 9'4" (112") PRECAST 554 689 1160 1625 2564 3486 2818 3302 9'-4" 112" PRECAST ( ) 326 512 230 9'4" (112") PRECAST sst 708 ) 113six1 1474ixi 1815,3v 2157, m 2500i3ni 752 1245 11143 2564 3486 4705,3a 639D,,,, 591 862 1318 1 1643 7969 2294 2619 10'-6" 126" PRECAST ( ) 475 535 a90 1247 2093 2777 2163 2536 10'-6" (126") PRECAST 284 401 160 10'•6" (126") PRECAST 530 575(z°) 916 ") 11881n: 1461,331 1736(,, 2011 i i s43 lost 1533 2os3 27a1 3sa3,35) a75a,u, 530 695 1180,eJ 1472,°) 1763,z) 2055 2346 1V4" (136") PRECAST 362 58z 9a5 1388 gas 2423 3127 4006 11'4" (136") PRECAST 260 452 154 11'4" 136" PRECAST ( ) 474 504(n) 8D0,3z, 1037(u, 127a,3z) 1513,3z) 1753(3z) 582 945 1366 1846 2423 3127 4006 494 607 104Z1o1 1372m) 1643,3) 1915,1 2187 (s) 12'-0" 144" PRECAST ( ) 337 540 673 254 684 2193 2805 3552 12'-0" (144") PRECAST 244 402 137 12'-0" (144") PRECAST 470 ,9) 458, 3) 724 , 938 1 i 1153,3z) 1369 1585 n Sao 873 1254 1684 2193 2805 355z 470 550 949„0) 1302(, 1560u3) 1818(n, 2075„0l 13'4" 160" PRECAST ( ) 296 471 755 1075 1428 B38 2316 2663 13'4" (161 PRECAST 217 324 110 471 755 1075 1428 1338 2316 2883 13'4" (160") PRECAST 418 „s/ 386,) 607,301 785 30) 964,s0, 1143,s, 1323 3,) aze 460 Teo 1159121 tata,zcJ 185$19) 1687pn 14'-0" 168" PRECAST ( ) 279 424 706 1002 1326 1697 2127 2630 14'-0" (168") PRECAST 205 293 100 14'-0" (168") PRECAST 384 „5) 358,z,) (9) %0,z9) 724 (30) 889,3m 1054,30) 1220,3o) 442 706 1002 1326 1697 2127 2630 410 425 717 (9) 10631zn 1358(23J 1582¢) 1807¢,) 14'-8" 176" PRESTRESSED ( ) N.R. NR NR NR NR NR NR NR 14'-8" (176") PRESTRESSED N.R. 284 91 14'-8" (176") PRESTRESSED 239 248 334R,) 395 520(29) 663 672(z9) 980,z0) 825,m1 1303,zs) 978(z9) 1518,zs) 11313o) 1734,za) 458 78a 1370 1902 2245 2517 2712 15'4" 184" PRESTRESSED ( ) N.R. NR NR NR NR NR NR 15'4" (184") PRESTRESSED N.R. 259 83 15'4" (184") PRESTRESSED 224 230 3131zo)t 368 9 7,z9) 759,zs) 1240, 911(a9) 1460,z7) 1054R9) 1668(26) 1" 472 710 1250 1733 zosa 23z0 zs13 1T4" (208") PRESTRESSED N.R. NR NR NR NR NR NR NR 17'4" (208") PRESTRESSED N.R. 194 64 7T4" (208^) P 87 92 263 ry9)12i1 306 ,z0) p9) 1 638 127) 1005,z:) 756 ,zD 1271,3,7 873 ,ny 1473,3p19'4" 3DD Sae s5o 132s 609 18as 2Da7 232" ( )PRESTRESSED N.R. NR NR NR 19'4" (232") PRESTRESSED N.R. 148 52 z3s 42 ago 75 7so 1037 03 tzez 1515 51 nts 19'4" (232") P66 62 229,,,7,z) 253 (u) 547,25) 841 ,,) 647(z3) 1059(30 747,zn 1227,3o) 21'4" 256" ( )PRESTRESSED N.R. NR NR NR NR NR NR NR 21'4" (256") PRESTRESSED N.R. 125 42 180 Sao 598 845 a 1359 lase 21'4" (256") P 2 4124 204 ne) 307,3) 393 >) 480 ,z3) 568 ) 655,m) 2 232 373 (1) 537 I,p 721 ,1 905,zv 1048(, 22'-0" (264") PRESTRESSED N.R. NR NR NR NR NR NR NR 27-0„ 264" ( )PRESTRESSED N.R. 116 40 165 315 550 784 1041 1285 139s 22'-0" (264") P 7 37 197„s) 223 295,) 358 ,7 379 3) 513 „7) 462,z3) 6881, 546,37 863 o) 630,z3) 999 (25) 24'-0" (288") PRESTRESSED N.R. NR NR NR NR NR NR NR 24,-0„ (288") PRESTRESSED N.R. 91 33 12 25 45 654 1092 22 1222 24'-0" 288" P24 ( ) 4 ns"°, 202 2s7,z„ 319 (7)1 3az,z,) 455 i,el ats(z„ 606,z37 492 ,) 757 ,u)l 567 , 876 ,zn (#) THE NUMBERS IN PARENTHESIS REDUCTIONS FOR GRADE 40 FIELD ARE PERCENT ADDED REBAR. (#) THE REDUCTIONS NUMBERS IN PARENTHESIS FOR GRADE 40 ARE FIELD ADDED PERCENT REBAR. - ALL VALUES TAKEN FROM "SAFE LOAD TABLES" BY CASTCRETE MAY 2015 EDITION - ALL PRECAST PRODUCTS ARE TO BE INSTALLED PER MANUFACTURES SPECIFICATIONS - PRECAST PRODUCTS BY OTHERS TO MEET OR EXCEED VALUES STATED ABOVE - PROVIDE MINIMUM 4" OF BEARING PAST EACH SIDE OF WINDOW OPENING PRODUCT CONTROL NOTICE OF ACCEPTANCE F.E.C.P. CORPORATION-CASTE-CRETE DIVISION ACCEPTANCE #: 16-01<36.03 0 r. Ir�.__— _ 8F161T/0M/0B--___8F16-1T/0M/0B —__. —� — — 8F16-1T/OM/OB ° 1 1 - ♦♦♦ 2 0 ° of mmm 1 ♦ S2.1 ° 1 1 ♦♦ o °° 01 ♦ GT co°° 001 1 - I ♦ 1 T/0M/0B 1 i� - I- I -_ 1 1 ♦♦♦ - 1 1 ♦ °° 1 ♦♦ °° 1 1 ♦ ♦ 1 1 ♦♦♦♦ 1 I ♦♦♦ I°° 1 I I 1 I ♦♦♦ 1 I y 1 I 1 1 REVIEWED FtJR j I 1 I CODE COMPLIANCH 1 ST, LUCIE COUNTY I BOCC, 1 � I 1 I 1 1 1 �1 1 L1 1 1 1 1 1 UNO, PROVIDE B131 WHERE 1 1 ROOF TRUSSES BEAR, TOP 1 1 OF WALL EL. 8'-1 UNO. 1 I 1 1 1 1 1 I 1 r I 1 1 1 ♦ 1 1 ♦♦ 1 1 1 ♦♦♦ , ' ILE COSY 1 % I ♦♦ 1 ° ♦� 1 8F8- ° 1 T,/OM/OB GT ° 1 ° 1 40 I 1 1 8F28-1 T/OM/0B 1 ° 1 1 _ 8F16-1T/0M/0B 1 1 1 LIFT BEAM PLAN SCALE: 1/4" = V-0" 551 S. APOLLO BLVD. MELBOURNE, FL 32901 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 1014 03 U W 0 4 A F p ti svaDly ag LOT: CREEKSIDE LOT 70 PROJECT#_ 4321.000 070R1 DdODEL: 4EAB "1672-ARIA" GARAGE SWING: LEFT PAGE: LIFT BEAM PLAN AND NOTES 160 MPH EXP. C ARCHITECT STATE OF FLORIDA MICHAEL C. ANDERSON 4.AR NO 17305 r,,. ` 08 5 19 DATE: / / SCALE: 1/4"=1'-0" SHEET S 2 NOTES TO THE INSPECTOR/CONTRACTOR TYP.8"x8" 1. PLACE LINTEL ACROSS TOP OF OPENING. BOND BEAM-1#5 2. IF BOTTOM STEEL IS REQUIRED PLACE #5 BAR IN LINTEL. PLACE STEEL 3. HEIGHTE MASONRY UNITS AS REQUIRED TO ACHIEVE THE REQUIRED BEARING REINFORCING (L2) 4_ THE LAST COURSE WILL BE A BOND BEAM WITH (1) #5 BAR CONTINUOUS AROUND AS DEPICTED HEREIN. STRUCTURE. A DOUBLE BOND BEAM MAY BE SPECIFIED SO THAT THEN THE LAST - - 1#5 TWO COURSES ARE BOND BEAMS WITH A #5 BAR IN EACH COURSE. TYP. 8"x16" - �QP 5. SHOULD THE DOUBLE BOND BEAM COINCIDE WITH A LINTEL THE BOTTOM BOND BEAM #5 CORNER BAR W/ 30" LAP FOR EACH OJ COURSE OF BOND BEAM IS OMITTED AND A LINTEL IS PLACED. THE STEEL COURSE OF BOND BEAM / REINFORCING FOR THE BOTTOM BOND BEAM IS TO BE CONTINUOUS THROUGH THE 1#5 TOP OF THE LINTEL. VERTICAL REBAR W/ 10" HOOK / 1' \�' Q 6. LINO COMPOSITE MASONRY BEAM IS TO BE NOT LESS THAN 16" DEEP. B 8x16 DBL. BOND TOP OF \p(\� $ QP BEAM W/ (1) #5 BAR = BOND BEAM EACH COURSE OQ��\�O • W8(BON BAR BOND TOP OF 30 TYPICAL F F =FILLED W/ GROUT -(Y\O EAM U =UNFILLED BEAM COURSE GROUT SOLID FROM TOP NOMINAL LINTEL TO TOP OF BOND OF OPENING #5 BAR IN BOND BEAM WIDTH # OF #5'S, IN 2ND BOND BEAM � SEE NOTE 5 16-1 T/ 1 M/0 B 8x8 PRE -CAST CONCRETE NOMINAL —�' LINTEL W/ (1) #5 BAR (L2) CORNER g"Q HEIGHT #OF#5'S,TOP OPENING NGTOFBAR=WIDTHOF MASONRY BOND BEAM COURSE ORIT IS n BEAM DESIGNATION 1 REINFORCING O F BOND BEAM THAT HIS ENGINEER'S INDICATES A DOUBLE BOND BEAM # OFPLA#5'SNBONTOM 8x8LINPRE-CAW/O STECONCRETE EL REFER SCALE: 3/4"=1'-O' AND XFXX - 1T/OM/06 INDICATES A SINGLE BOND BEAM TO PLAN FOR LOCATIONS - TOP OF OPENING PRECAST HEADER(MIN) 2x4 (MIN 2 X 3)1-3/16 TAPCON OR DRIVE PIN (MIN SHANK SIZE.145 MIN HEAD WINDOW SIZE .300 MIN EMBEDMENT 1 1/4") 8" FROM EACH END AND 18" O.C. MAX. MIN 1-1/4" EMBEDMENT 2x6 MIN 2 X 3 2-3/16 TAPCON ( GO 1 ) /4" PRE -CAST eN WINDOW OR DRIVE PIN ( MIN SHANK � SILL Z - - SIZE.145 MIN HEAD SIZE .300 MIN EMBEDMENT 1 1/4") 8" 'ESLOPE FROM EACH END AND 18" O.C. MAX. MIN 1-1/4" cl' EMBEDMENT - 2x8 (MIN 2 X 3) 2-3/16 TAPCON OR DRIVE PIN (MIN SHANK SIZE.145 MIN HEAD SIZE .300 MIN EMBEDMENT 1 2X4 SOLID BLOCKING 1/4") 8" FROM EACH END AND SECURE TO SHEATHING W/ 18" O.C. MAX. MIN 1-1/4" MIN. 2-12d PER BLK. EA. END EMBEDMENT TYPICAL MASONRY WINDOW 7/16" OSB SHEATHING SILL CONSTRUCTION CMU WALL SCALE:11/2"=1'-0" 5 ARCHWAY FRAMING DETAIL SCALE: 3/4"=1'-0" RE 'ZWED FOR JOUE uOMPLIANOE a k.10CIE COUNTY BOCC I FILE COPY C 5515. APOLLO BLVD. MELBOURNE, FL 32901 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 W U W 0 F U O F Q ti sVBDIV. 8e LOT: CREEKSIDE LOT 70 PROJECT# 4321.000/070R MODEL: 4EAB "1672-ARIA" sARAGE SWING: LEFT PAGE: DETAILS 160 MPH EXP. ARCHITECT. STATE OF FLORIDA AMCHAEL C. ANDERSON AR NO T7305 PRINT 08 5 19 DATE: / / SCALE:1/4 t1=1 - 0" SHEET Ste 1 FRAMING NOTES: 1. U.N.O. ALL STRAPS FOR ROOF TRUSSES TO BE CONCRETE TO WOOD ROOF: USP HTA16 W/ (9) 10d x 1 1/2" HDG NAILS. CONCRETE TO WOOD FLOOR: USP LPTA W/ (10) 10d x 1 1/2" HDG NAILS, WOOD TO WOOD: USP RT16A OR LUGT2 W/ 10d x 1 1/2" HDG NAILS, FILL ALL HOLES. 2. ALL PLYWOOD FOR WALL AND ROOF SHEATHING IS TO BE PER FASTENER SCHEDULE. 3. ALL PLYWOOD FOR FLOOR SHEATHING SHALL BE PER FASTER SCHEDULE MEETING THE REQUIREMENTS OF AFG-01 AND APPLIED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 4. ALL NAILS FOR TRUSS TO BEAM AND TRUSS TO TRUSS METAL CONNECTORS ARE TO MATCH CONNECTOR FINISH. 5. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON LINTEL MANUFACTURER SHOWN IN STRUCTURAL PLANS. 6. BOTTOM OF LINTELS ARE TO BE PLACED AT TOP OF WINDOW, DOOR AND CLEAR SPAN OPENINGS. 7. LINTELS SHALL HAVE 4" NOMINAL BEARING (4"). 8. THE TRUSS FRAMING SHOWN IS SCHEMATIC IN NATURE. HOWEVER THE SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRUSS DESIGNERS LAYOUT. SUBMIT FINAL TRUSS DRAWINGS FOR THE ENGINEER'S REVIEW AND APPROVAL. 9. PLACE 2x4 PT TO ALIGN WITH TOP AND BOTTOM CHORDS OF ROOF TRUSSES SECURE 2x MEMBERS TO WALL WITH HILTI X-ZF, POWDER ACCTUATED FASTENER, ZF 72 P8S36, .177" ° x 2 7/8" LONG, WITH WASHER @ 16" O.C. 10. TRUSS REACTIONS AND UPLIFTS SHOWN ARE THE SAME ON EACH END UNLESS OTHERWISE SHOWN DIFFERENT. 11. WOOD BEARING WALLS AND HEADERS HAVE BEEN DESIGNED BASED ON RATIONAL ANALYSIS. 12. ALL ELEVATIONS ARE REFERENCED FROM 0'-0", FINISH FLOOR. UNLESS NOTED OTHERWISE. TRUSS MANUFACTURER / ENGINEER NOTES: 1. ROOF GIRDERS W/ UPLIFT IN EXCESS OF 2,500 LBS SHALL BE FABRICATED W/ A 2x6 BTM. CHORD (MIN.) 2. COORDINATE ANY TRAY/COFFEREC) CEILINGS, AND ATTIC ACCESS WITH THE ARCHITECTURAL PLANS TRAYS AND COFFERS ARE NOT SHOWN ON THIS PLAN IN ORDER TO AVOID CONFUSION AND MISTAKES. 3. TRUSS COMPANY / ENGINEER IS RESPONSIBLE FOR ALL TRUSS TO TRUSS CONNECTIONS. 4. AVOID PLACING A TRUSS PERPENDICULAR TO A STEEL COLUMN. MAINTAIN AT LEAST 8" FROM THE CENTER OF THE COLUMN. CJ1 o CJ3 � CJ5 A 1A 3.1 CJ5 CJ3 CJ1 2X4 BLOCKING BETWEEN TRUSSES 24" O.C. TOE NAILED TO ADJACENT TRUSSES W/ (2) 16d COMMON NAILS & SECURE TO BM. W/ USP HLPTA75 USED TO U U U BRACE TOP OF WALL. 11 1 1111 - -1r 11 - 11 11 '- - 11 ii EJ7 11 11 11 n n u u u n II II II II II II ATTACH 4'-0" LONG 2x SCAB TO TRUSS W/ 10d NAILS @ 6' O (4" FROM EA. EN.C.D) GT 1111 II II A3 ATTIC _ — _ - ACCESS A4 �e Al A6 W II III �I WII p u u U U 0 CJ1 CJ3 CJ5 1A / L- - '�'. -- - - . J -- - /- PRE -FABRICATED R OF _- TRUSSES @24"O.C. ----- _-- A7 /� 53.1 = AV4 8GGT a II II II II II II I III 1A -� = II II 11 II II II II II %' 3.1 II II II I� II EJ7 II II coC1GE U U U to w 7 8 c� CE FRAMING PLAN SCALE: 1/4" = V-0" 1A 1A REVIEWED FOR CODE COMPLIAr I , LUCIE CO UN z : '' BOCC FILE COPY 551 S. APOLLO BLVD. MELBOURNE, FL 32901 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 W W 24 113 0 U W 4 r4 q I ti SU13DIV. & LOT: CREEKSIDE LOT 70 PROJECT# 4321.000 070R1 MODEL: 4EAB "1672-ARIA" GARAGE SWING: LEFT PAGE: FRAMING PLAN 60 MPH EXP. C ARCHITECT - STATE OF FLORIDA MICHAEL C. ANDERSON BAR NO 17305NO 17305 0 r� &N ` OS 5 19 DATE: / / SCALE: 1/4"=1'-0" SHEET S 3 ENGINEERED WOOD TRUSSE PLYWOOD SHEATHING, SEE @ 24" O/C, SUBMIT SHOP "ROOF/WALLIFLOOR DRAWINGS FOR REVIEW SHEATHING AND APPROVAL FASTENER SCHEDULE" PLYWOOD SHEATHING, SEE (2) USP HTA16 TRUSS ANCHOR # 1175 UPLIFT USP "ROOF/WALL/FLOOR WITH (9) 10d x 1 1/2" NAILS TO HTWM20 W/10 10d TO SHEATHING TRUSS EA. PROVIDE 4" MINIMUM NOTE: FOR (A) WJ SINGLE TRUSS AND (4) 1/4" x 2 1/4" FASTENER SCHEDULE" CONCRETE EMBEDMENT. DBL PLY, A PT SYP #2 2"X6"X4'-0" TAPCONS TO CONT STRAP, 1 EACH SIDE WRAPS UP MAY BE ADDED W/ 10d POURED LINTEL A-(1)USP HTA16 TRUSS ANCHOR WITH (9) AND OVER TRUSS (NOT NAILS, 2 ROWS, 3" O/C TO 10d x 1 1/2" TO TRUSS. FL#17680 SHOWN) FACILITATE 2-PLY # 1900 UPLIFT (2) USP B-(2) USP HTA16 TRUSS ANCHOR WITH (9) USED IN CONJUNCTION WITH CONNECTOR. HTWM20 INSTALLED ON PRE-ENG TRUSS 10d x 1 1/2" TO TRUSS EA STRAP. FL#17680 HEAVY UPLIFT CONNECTOR OPPOSITE FACES OF DBL STRAP, 1 EACH SIDE WRAPS UP AND FL#17680 BLOCK WALL W/10 10d TO OVER TRUSS (NOT SHOWN) (A) USP LUGT2 W/ (5) 1/4"x3' POWERS TRUSS AND (4) 1/4" x 2 1/4" TAPCONS TO CONT CONTINUOUS BOND BEAM 1x2, 2x WOOD FASCIA WEDGE BOLT& (16) 16 GALV. NAILS TO POURED LINTEL SEE ARCHITECTURAL TRUSS (2PLY) #FL17240 (NOT SHOWN) 2x SECURED W/ (3) 16d(B) Xil USP RFUS STEEL CONNECTOR WITH (4) GALV. COMMON NAILS. ENGINEERED WOOD 3/4"x6" WEDGE BOLTS AND 1x2 SECURED W/ 10d TRUSSES @ 24" O/C, 1x2, 2x WOOD FASCIA (12) WS3 SCREWS FL#6223 GALV. COMMON NAILS - SUBMIT SHOP DRAWINGS SEE ARCHITECTURAL 12" O/C FOR REVIEW 2x SECURED W/ (3) 16d IF 4 BOLTS ARE USED AND APPROVAL GALV. COMMON NAILS. Ix2 SECURED W/ 10d MASONRY BOND ENSURE THAT CELLS ARE GROUTED GALV. COMMON NAILS BEAM SOLID. 8" EACH WAY OF BOLTS MASONRY BOND BEAM 12" O/C SEE SCHEDULE SEE SCHEDULE A ALLOWABLE UPLIFT = U:3980 LBS, L:1785 LBS (2PLY) A ALLOWABLE UPLIFT = LIA 870 LBS, L:710LBS (1 STRAP) B ALLOWABLE UPLIFT = U:9000 LBS, L:1310 LBS (4 WEDGE BOLTS IN RFUS) TAP CONS MIN. 2" B ALLOWABLE UPLIFT = U:2430 LBS, L:1310LBS (2 STRAPS) COVER 2" APART REPAIR OF MULTIPLE TYPICAL TRUSS/ TYPICAL ROOF MISPLACED EMBEDDED TRUSS ANCHOR 1 a 1 b GIRDER CONNECTORS) SCALE:3i4"=1'-0" 2a () 2b SCALE:3/4"=1'-0" GIRDER CONNECTOR(S) SCALE:3/4"=1'-0" (2) 2X4 Not SYP DIAG. 2x4 BLOCKING BETWEEN BRACE W/ (3) 12d @ EA. TRUSSES WHERE TRUSS (DIAG. BRACE TO X-BRACING IS PRESENT AT COVER 5 TRUSSES) 4'-0" O.C. (AT SHEATHING 0'-0" TO 30'-0" (1) "X" BRACE SEAMS) 30'-1" TO 60'-0 (3) "X" BRACE SECURE 2x8 PT. PLATE (1) "X" BRACE @ CENTER 11r TO BLK W/ 1/2" DIA. (2) "X" BRACE DIVIDED EQUALLY 74 ANCHOR BOLT W/ 2" 6-0" MAX (W/1 X4) FROM CENTER TO END. WASHER SET IN HIGH OR 10'-0" MAX (W/2X4) 2x WOOD FASCIA, STRENGTH EPDXY 6" V SEE ARCHITECTURAL MIN. EMBED. AT 32" OC MAX. 1x4 DIAGONAL PRE-ENG GABLE TRUSS SECURE GABLE TO2x8 P.T. PLATE W/ 12d's 8" BTM. CHORD BRACING, SEE STIFFBACK (AS PER O.C. MAX PLAN FOR LOCATION TRUSS ENG) CONT. 2x4 SECURED W,' w U o a- MAY NOT BE (2) 10d's @ EACH TRLISS OC J } REQUIRED - TO BE INSTALLED @ iv F a 1 U-0" O.C. MAX. BTM. CHORD OF WOOD ROOF TRUSSES SEE SCHEDULE FOR BOND BEAM REQ. y' _ REVIEWED FOR `ODE COMPLIANCE ST. LUCIE COUNTY BOCC 1x4 BTM. CHORD BRACING 6'-0" O C END WALL OR OTHER MAX., OR 2x4 BTM. CHORD BRACING END TYPE CONDITION, IF 10'-0" O/C MAXSECURED W/ (2) 10d DEPICTED SEE PLAN BLOCK WALL W/ GABLE END COMMON NAILS AT EACH CHORD 0-NOT INTERSECTION TYP. BTM. CHORD BRACING PRE-ENG'D TRUSS SCALE:3J4"=1'-0" 6 USED SCALE: 3/4"=V-0" 5 FILE COPY NOT USED 4 THE USE OF ALTERNATE MATERIALS MAY BE NOTCH DEPTH 1/4'D USED S AS THEY CONFORM T THE HOLE EDGE >5/8" FOLLOWING HOLE DIAMETER <2/5'D SGL. STUD 1. METAL STRAPS FOR ROOF AND FLOOR CONNECTIONS OUTER 1/3 OF A) AN ALTERNATE STRAP MAY BE USED SO LONG AS THE NEW STRAP HAS SPAN ONLY EQUIVALENT OR GREATER UPLIFT AND LATERAL (F1 AND F2) LOAD CAPACITIES AS THE ONE SPECIFIED, CONCURRENTLY. IT SHOULD BE NOTED FLOOR AND HOLE EDGE >5/8" ROOF TRUSSES ARE SUBJECT TO LATERAL LOADS DUE TO WIND AND REQUIRE THE CONNECTIONS INDICATED. A FLAT OR TWIST STRIP IS NOT EQUIVALENT TO A USP RT16A (FL#17236) OR LUGT2 (FL#17240). ROOF TRUSSES ARE SUBJECT TO UPLIFT. Fl. AND F2 FORCES ALL AT THE SAME TIME. FLOOR TRUSSES NOT EXPOSED TO WIND ARE SUBJECT TO F1 AND F2 FORCES. BTM. HOLE DIAMETER PLATE < 3/5"D DBL. STUD ALTERNATE MATERIALS STUD NOTCHING NOT USED NOT USED 11 SQALE:3/4"=1'-0" AND BORING LIMITS g 10 8 SCALE: 1 1 /2"=1'-0" 551 S. APOLLO BLVD. MELBOURNE, FL 32901 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F19 W 0 0. w 4 A E4 ti SUBDIV. 8e LOT: CREEKSIDE LOT 70 PROJECT* 4321.000 070R1 MODEL: 4EAB "1672—ARIA" GARAGE SWING: LEFT PAGE: DETAILS L60 MPH EXP. JC ARCHITECT - STATE OF FLORIDA 161� MICHAEL C. ANDERSON AR NO 17305 DA 08/5/19 SCALE: 1/4"=1'-0" SHEET Sae 1A PRE-ENG GABLE TRUSS 2x4 BLOCKING BETWEEN TRUSSES AT FIRST TWO BAYS 4'-0" O.C. (AT SHEATHING SEAMS) (BLOCKING NOT SHOWN FOR CLARITY) 2X4 DIAGONAL BTM. CHORD BRACING. SEE PLAN FOR LOCATION SECURE 2x6 PT. PLATE TO BLK- W/ 1/2" DIA. ANCHOR BOLT W/ 2" WASHER SET IN HIGH STRENGTH EPDXY 6" MIN. EMBED. AT 32" OC MAX. SECURE GABLE TO 2x8 P.T. PLATE W/ 12d's 8" O.C. MAX n PRE-ENG'D WOOD TRUSS (TYP) @ 24" O.C. MAX FOR STRAPPING VERIFY W/ TRUSS PLAN CONC.POURED LINTEL COURSE CONT. 2x4 SECURED W/ (2) 10d's @ EACH TRUSS TO BE INSTALLED @ 10'-0- O.C. MAX. GABLE END BRACING W/ PRE-ENG GABLE TRUSS @a CMU WALL SCALE: 3/4"=1'-U' -IEVIEWED FOR DE COMPLIANCE i'. LUCIE COUNTY BOCC FILE COPY 551 S. APOLLO BLVD. MELBOURNE, FL 32901 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F WW y 0 V W O F U y W 4 E� A SVBDIV. 8e LOT: CREEK7 E LOT 70 PROJECT# 4321.000 070R1 MODEL: 4EAB "1672-ARIA" GARAGE SWING: LEFT PAGE: DETAILS 60 MPH EXP. JC ARCHrrECT- STATE OF FLORIDA WCHAEL C. ANDERSON AR NO T7305 DATE: 08/'5/19 SCALE: 1 /4"=1'-0 SIMET S3. 1B (2) 2X4 No.2 DIAL. BRACE W/ (3) 12 EA. 2x6 OUTLOOKER @ 24" SECURED W/ USP R A L I '\ VTT SPACING (1) AT EACH END II (', pggpppppp ppppgpppp pppplpupu ppppppppp TRUSS (DIAL. BRAC 0 VTT AND 6-0" O.C. MAX. COVER 5 TRUSSES) 2x SUB -BAND 0'-0" TO 30'-0" (1) "X" BRACE 30'-1"TO 60'-0 (3) "X" BRACE (1) "X" BRACE @ CENTER PRE- G GABLE TRUSS pggplpqpl (2) "X" BRACE DIVIDED EQUALLY A TALL " I I l l ppgplllp FROM CENTER TO END. UPRIGHTS O 4'-10' H UPRIGHTS p p p p p p l l p E; (AS PER TRUSS ) I I pgVpppppV 0 PLYWOOD SHEATHING, SEE —� "ROOF/WALL/FLOOR SHEATHING FASTENER SCHEDULE" SEE TYP. TRUSS CONNECTOR DETAIL FOR STRAPPING INFO.CONNECTION PE 1x2, 2x WOOD FASCIA TRUSS MFG. SEE ARCHITECTURAL 2x SECURED W/ (3) 16d ENGINEERED WOOD SIDE VIEW GALV. COMMON NAI TRUSSES @ 24" O/C, 1x2 SECURED W/ d _ SUBMIT SHOP DRAWINGS GALV. COMM NAILS FOR REVIEW CONT. 2x4 RAT RUN 12" O/C AND APPROVAL SECURED W/ (2) 12d's @ M NRY BOND BEAM EACH TRUSS ESCHEDULE GABLE END PRE-ENG'D TRUSS PRE-ENGINEERED 1 W1 HIP RETURN SCALE:3/4"-1'-0" VALLEY TRUSS CONNECTION 2 SCALE: N.T.S. P'711EWED FOR fir` OV,, OMPLI.ANCE CIE CCM,,, `tT BOCC r COPY 551 S. APOLLO BLVD. MELBOURNE, FL 32901 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F R4 P3 U W 0 F ON V W A A mmmmmm SUBnIV. 8e LOT: CREEKSIDE LOT 70 PROJECT# 4321.000 070R1 MODEL: 4EAB "1672- ARIA" GARAGE SWING: LEFT PAGE: DETAILS 60 MPH EXP. C ARCHITECT STATE OF FLORIDA 08/5/19 I SCALE: 1/4"=1'-0"' SHEET S3.IC . s u A. a a� A GABLE -END HIP ROOF ROOF WIND DESIGN PRESSURES NET (GROSS) ASCE 7-10 ZONE 1 = 23.79 PST (33.79) ZONE 2 = 39.48 PSF (49.48) ZONE 3 = 67A6 PSF (77.16) "A"= 4'-0" END ZONE DISTANCE BASIC WIND SPEED: 160 MPH WIND EXPOSURE: "C" RISK CATAGORY: II APPLICABLE INTERNAL PRESSURE COEFFICIENT +- 0.18 ROOF DIAPHRAGM FOR ASPHALT SHINGLE ROOF, USE MIN 7/16" O.S.B. OR 1/2" CDX EXT. PLYWOOD, FOR CEMENTITIOUS TILE AND METAL ROOFING, USE MIN. 5/8 CDX EXT. PLYWOOD, WITH 8d RING SHANK GUN NAILS AT 4" O.C. AT SUPPORTED PANEL EDGES AND 8d RING SHANK GUN NAILS AT 6" O.C. AT INTERMEDIATE SUPPORTS. SEE DETAIL. ROOF SHEATHING TO GABLE END FRAME USE 8d GUN NAILS @ 4" O.C. EDGEWISE 2x4 BLOCKING ALL PANEL JOINTS W/ IN 4' OF GABLE END. ROOF/ WALL/ FLOOR SHEATHING FASTENER SCHEDULE NAIL SCHEDULE SIZE TYPE MIN. LENGTH MIN. DIA. SHANK TENSILE STR. SHANK - 8d RING SHANK, 2 1/2" 0.120" 170.000 RING SCREW SHANK (16-20 RINGS PER INCH) 8d SCREW SHANK 2 1/2" 0.120" PNEUMATIC SCREW -NAILS 1. NAIL SIZE PER ASTM F1664 2. INTERNATIONAL STAPE, NAIL & TOOL ASSOCIATION (]SANTA) ESR-1539 EXTERIOR SHEATHING USE 1/2" CDX OR 7/16" O.S.B. PLY WITH 8d RING SHANK GUN NAILS AT 4" O.C. AT PANEL SIDES AND 8d RING SHANK GUN NAILS 4" O.C. TOP & BOTTOM PANEL AND 8d RING SHANK GUN NAILS AT 6" O.C. AT INTERMEDIATE SUPPORTS OR 7/16" ZIP SHEATHING SYSTEM (INSTALLED PER MANUF. SPECS.) SEE DETAIL. J Z (LU Z Q W Y @U Q U =O C3 Z E 00 8dRING SHANK GUN NAILS @ 4" O.C. TOP & BOTTOM EDGES „ J a / i Z Z D O . LU m Z 2 Co Z U 0 CO In o @J Z j m U Y Z Q x U) C7 Z F . co @J J Q Z LU Z2 CD LU Y =U Ud Z 00 J Q Y Z fn aw Lu N W J U `� 0 .) U n< O X3 Li Z a TOP CORD BLOCKING AT 4' O.C. MAX. IN FIRST 2 FRAMING SPACES AT EACH END. RAFTER OR TRUSS——, ROOF SHEATHING z x 0 0 m BUILDING LENGTH n ROOF SHEATHING LAYOUT AND ENDWALL BRACING FOR GABLE END FRAMING C8d RING SHANK GUN NAILS C& 6" O.C. IN FIELD: TYP. EXT. SHEATHING ATTACHMENT FOR ROOF SHEATHING (O.S.B. TO BE STRUCTURAL GRADE) C8d RING SHANK GUN NAILS @ 12" O.C. IN FIELD or 8d x 2 1/2" SCREW SHANK PNEUMATIC SCREW -NAILS @ 12" 0.6�(N FIELD TYP. 3/4" T&G SUB -FLOOR DECKING GLUED TO ALL EXPOSED MEMBERS GENERAL NOTES: STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND SITE DRAWINGS. CONSULT ARCHITECTURAL DRAWINGS FOR SLEEVES, DEPRESSIONS, AND OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS. APPLICABLE BUILDING CODE STANDARDS: FBC-R 2017,6th EDITION ACI 318-14 BU ILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE, ACI 530-13/ASCE 5-13 AISI SPECIFICATION FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS 2011, ASCE 7-10 AND AISC SPECIFICATIONS ALL DETAILS AND SECTIONS SHOW ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT, EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. DO NOT SCALE THE DRAWINGS. FOLLOW WRITTEN DIMENSIONS ONLY. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO PROCEEDING WITH THE AFFECTED PART OF THE WORK. THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND SEQUENCES TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS DURING ERECTION. THIS WORK INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, TEMPORARY BRACING, GUYS OR TIE -DOWNS. THE CONTRACTOR SHALL SUPPLEMENT THE MINIMUM REQUIRED FOUNDATION AND SITE PREPARATION REQUIREMENTS AND SLAB -ON -GRADE THICKNESS TO HANDLE CONSTRUCTION LOADS. ALL AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C33. MAXIMUM AGGREGATE SIZE SHALL BE 3/4", PROVIDE 6% AIR ENTRAINED CONCRETE EXPOSED TO EARTH OR WEATHER ALL EXPOSED ED GES OF CON CRETE CHAMFERED 3/4" PROVIDE 6-MIL CONTINUOUS POLYETHYLENE VAPOR BARRIER MEMBRANE UNDER ALL SLABS -ON -GROUND WHERE INDICATED ON DRAWINGS. SEAMS LAPPED 6 INCHES AND SEALED WITH ADHESIVE TAPE, FORM -WORK: FORM -WORK, SHORING, AND BRACING FOR ALL CONCRETE BEAMS, SLABS, COLUMNS, WALLS, AND FOOTINGS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH ACI 347, "RECOMMENDED PRACTICE FOR CONCRETE FORM -WORK. WOOD: NON -BEARING WOOD WALLS TOP PLATES & STUDS CAN BE SIFF. ALL WOOD FOR BEA MS, BEARING WALLS , SO LE PLATES TOP PLATES , BRACING, LEDGERS, BLOCKING, CRIPPLERS, SILLS, ETC., SHALL BE SOUTHERN PINE NO. 2 OR BETTER. Fb = 1100 PSI AND A MODULUS OF ELASTICITY = 1,400,000 PSI. ALL WOOD IN CONTACT WITH CONCRETE OR CONCRETE BLOCK SHALL BE PRESSURE TREATED. PRESSURE TREATED BOTTOM PLATE REQUIRED. WOOD FOR NON-STRUCTURAL USES SHALL BE RATED TO RETENTION LEVELS OF 0.25 PCF OF A BORATE PRESERVATIVE TREATMENT: DISODIUM CORROBORATE TETRAHEDRAL (DOT). WOOD FOR STRUCTURAL USE THAT SHALL BE TREATED FOR ANY REASON SHALL BE RATED TO RETENTION LEVELS OF 0.42 PCF FOR DOT OR MORE. NAILS, SPIKE, BOLTS USED W/ DOT SHALL BE HOT DIPPED GALV. FOR STRUCTURAL USES, AVOID BUYING TREATED LUMBER THAT CONTAINS MORE THAN 1/2" OF HEARTWOOD, EXCLUSIONS FROM THESE PLANS: MINIMUM NAILING PER FBCR 2017, 6th EDITION. SEE NAILING SCHEDULE ON PLANS. WATERPROOFING, FLASHING, SOUND ISOLATION, FIRE SEPARATION, OR OTHER NON STRUCTURAL ITEMS ARE NOT PART OF THE STRUCTURAL PLANS AS THEY ARE NOT CONSIDERED TO BE STRUCTURAL. DEPENDING PROVIDE SOLID BLOCKING UNDER ALL POINT LOADS AND WOOD COLUMNS WITH 2x STRUCTURAL LUMBER ON THE TYPE OF CONSTRUCTION THESE ITEMS SOME OR ALL MAY BE REQUIRED BUT ARE BY OTHERS. SYP #2. WELDED WIRE MESH: WELDED WIRE MESH, SHALL BE ASTM A185,. GRADE 65 AND BE PLACED IN ACCORDANCE WITH THE ACI TYPICAL DETAILS. MINIMUM LAP SHALL BE ONE SPACE PLUS TWO INCHES. WIRE MESH FOR SLABS SHALL BE SUPPORTED WITH 2" CHAIRS SPACED T-O" OC, EACH WAY. DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR REINFORCING STEEL: TO WORK PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND. REBAR SHALL BE ASTM A615 GRADE 40 IN CONCRETE DEFORMED BARS, REBAR SHALL BE ASTM A615 GRADE 60 IN MASONRY DEFORMED BARS, FREE FROM OIL,.. SCALE, AND RUST AND PLACED IN ACCORDANCE DESIGN LOADS: W/ THE TYPICAL BENDING DIAGRAM AND PLACING DETAILS OF THE ACI STANDARDS AND SPECIFICATIONS. CONTRACTOR SHALL SUBMIT REBAR SHOP DRAWINGS FOR REVIEW PRIOR TO FABRICATION. HORIZONTAL ROOF: LIVE LOAD FLOOR: LIVE LOAD 40 psf AND VERTICAL BARS SHALL LAP 8 X BAR NO. UNSCHEDULED FIELD LAPS ARE SUBJECT TO ENGINEER'S 20 psf TOP CHORD -non-concurrent REVIEW. 10 psf BTM CHORD -non-concurrent DEAD LOAD DEAD LOAD 15 pef TOP CHORD 20 psf TOP CHORD (7 psf w/ ASPHALT SHINGLES) (10 psf w/ No GYPCRETE) 10 psf BTM CHORD 5 psf BTM CHORD DEAD LOAD TO RESIST WIND UPLIFT: 1 Opsf BALCONY LIVE LOAD 60 psf STAIRS LIVE LOAD 40 psf WIND: DEAD LOAD SPEED =160 MPH 3- SECOND GUST (ASCE 7-10 (FBC R2017) EXPOSURE C, RISK CATEGORY II) LIVE LOADS: UNINHABITABLE ATTIC WITHOUT STORAGE: tOpsf, UNINHABITABLE ATTIC WITH LIMITED STORAGE:20psf, HABITABLE ATTICS AND ATTICS SERVED WITH FIXED STAIRS: 30psf, BALCONIES (EXTERIOR) AND DECKS: 40psf, GUARDS AND HANDRAILS: 200psf, GUARD IN -FILL COMPONENTS: 50psf, PASSENGER VEHICLE GARAGES: 50pef, ROOMS OTHER THAN SLEEPING ROOM: 40psf, SLEEPING ROOMS: 30psf, STAIRS: 40psf SHOP DRAWING REVIEW: SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGNING INTENT OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY COMPLIANCE WITH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS, ETC. TYP. MIN LAPS SHALL BE AS FOLLOWS: #4 BAR - 25" #6 BAR - 36" #5 BAR - 30" #7 BAR - 42" PROVIDE 36" x 36" CORNER BARS, BOND BEAM ONLY, LAPPED AND TIED TO EACH BEAM REBAR, SEE DETAILS FOR ADDITIONAL INFORMATION. UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE. SEAT PLATES SHALL BE PROVIDED AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES. WOOD TRUSSES: TO BE DESIGNED AND FABRICATED IN ACCORDANCE WITH THE "NATIONAL DESIGN SPECIFICATIONS FOR STRESS -GRADE LUMBER AND. ITS FASTENINGS" BY THE NFPA. TRUSS DESIGNS SHALL BE SIGNED AND SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN FLORIDA. SEE NOTED FOR SHOP DRAWINGS. CONNECTOR PLATES SHALL BE A MINIMUM THICKNESS OF 0.036" AND BE MANUFACTURED FROM STEEL MEETING THE REQUIREMENTS OF ASTM A446, GRADE A, AND SHALL BE HOT -DIPPED GALVANIZED. DESIGN, FABRICATE, AND ERECT WOOD TRUSSES IN ACCORDANCE WITH TPI-14, "DESIGN NATIONAL STANDARDS FOR METAL -PLATE -CONNECTED -WOOD TRUSS CONSTRUCTION:, AND "TPI/WTCA BCSI 1" COMMENTARY AND RECOMMENDATIONS FOR HANDLING, INSTALLATION BRACING METAL -PLATE -CONNECTED WOOD TRUSSES. TRUSS MANUFACTURER WILL PROVIDE CALCULATIONS INDICATING ADDITIONAL DEAD LOADS FOR THE ROOF LOCATIONS WITH GUSSETS, CRICKETS AND VALLEY LOCATIONS REQUIRING ADDITIONAL ROOF FRAMING FOR INTERSECTIONS OF HIGHER OR LOWER ROOFS IN ACCORDANCE WITH ANSI A58.1-1982, ALL VERTICAL REINFORCING BARS IN CMU CELLS SHALL BE ANCHORED IN THE FOOTING, HURRICANE STRAPS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTIONS. THICKENED SLAB, BEAM OR LINTEL SUPPORTING THE WALL AT THE TOP AND BOTTOM WITH MINIMUM 10 INCH HOOKS OR BENDS AND SHALL BE CONTINUOUS THROUGHOUT THE HEIGHT OF THE CONTRACTOR SHALL SUBMIT SIGNED AND SEALED DRAWINGS FOR ALTERNATE CONNECTION DETAILS AT WALL. TRUSSES/GIRDERS TO COLUMNS AND WALLS FOR APPROVAL. RUN REINFORCING BARS CONTINUOUSLY LAPPED AT SPLICES AND AROUND CORNERS. DOWEL ROOF & FLOOR LAYOUTS PROVIDED ON THESE PLANS ARE TO BE USED AS A GUIDE FOR BEARING INTO INTERSECTING WALLS AND HOOK AT ENDS. STAGGER SPLICES WHEREVER POSSIBLE. DETERMINATIONS, FEASIBILITY & ARCHITECTURAL AIDE. TRUSS MANUFACTURER IS RESPONSIBLE FOR FINAL LAYOUT, SPANS & ALL TRUSS/ HEADER ENGINEERING. ANY DISCREPANCIES FROM THESE LAYOUTS THAT DO NOT CUT OR DISPLACE REINFORCING STEEL TO ACCOMMODATE THE INSTALLATION OF EMBEDDED ITEMS AFFECT THE STRUCTURAL BEARING AS CALLED OUT ON THESE PLANS SHALL BE NOTIFIED TO THE WITHOUT THE APPROVAL OF THE ENGINEER. STRUCTURAL ENGINEER OF RECORD PRIOR TO MANUFACTURE OF TRUSSES. THE TRUSS FABRICATOR SHALL PROVIDE ENGINEERED SHOP DRAWINGS OF EACH INDIVIDUAL TRUSS AND A FULLY DIMENSIONE MASONRY: MASONRY CONSTRUCTION AND MATERIALS SHALL CONFORM WITH ALL REQUIREMENTS OF THE "SPECIFICATION MASONRY STRUCTURES" (ACI 530/ ASCE 5/TMS 402, BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES AND SPECIFICATIONS FOR MASONRY STRUCTURES AND COMMENTARIES), AS PUBLISHED BY THE MASONRY STANDARDS JOINT COMMITTEE. ALL BLOCK WALLS SHALL BE TWO=CELL HOLLOW CONCRETE MASONRY REGULAR SIZE BLOCK ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTORS PRIOR TO SUBMITTAL TO THE ARCHITECT. MANUFACTURED IN CONFORMANCE WITH ASTM C-90, GRADE I'm - 1500 PSI. BLOCK SHALL BE PLACED USING DRAWINGS SUBMITTED WITHOUT REVIEW WILL BE RETURNED UNCHECKED. SHOP DRAWINGS IN THE FORM RUNNING BOND UNLESS OTHERWISE NOTED. LAY-UP MASONRY WALLS TO BOTTOM OF TIE BEAMS BEFORE OF REPRODUCIBLE SEPIAS OF STRUCTURAL DRAWINGS (CON -TRACT DOCUMENTS) ARE PROHIBITED PLACING CONCRETE FOR IN -WALL COLUMNS. GROUT USED TO FILL MASONRY CELLS SHALL COMPLY WITH WITHOUT THE EXPRESS WRITTEN PERMISSION FROM THE ENGINEER. IN ALL INSTANCES, THE CONTRACT ASTM C-476, AND SHALL PROVIDE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS, UNLESS DOCUMENTS WILL GOVERN OVER THE SHOP DRAWINGS CHECKED, UNLESS OTHERWISE SPECIFIED IN SPECIFICALLY NOTED OTHERWISE ON FOUNDATION PLAN. THE GROUT MIX SHALL HAVE A MAXIMUM 3/8" WRITING BY THE ARCHITECT. COURSE AGGREGATE, AND SHALL BE PLACED W/ A SLUMP OF 8" TO 10". USE ONLY MECHANICAL VIBRATION TO CONSOLIDATE GROUT. FOUNDATION/ SITE PREPARATION: FOOTINGS WERE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 psf, FOOTING EXCAVATIONS AND SLAB SUB -GRADE SHALL BE COMPACTED TO A DRY DENSITY OF AT LEAST 95%OF THE MODIFIED PROCTOR MAXIMUM DRY DENSITY, DETERMINED IN ACCORDANCE WITH ASTM D-1557. TREATALL SOIL FOR TERMITE PROTECTION, THE OWNER SHALL RETAIN THE SERVICES OF AN INDEPENDENT GEO-TECHNICAL ENGINEER TO VERIFY SUCCESSFUL COMPLETION OF SITE PREPARATION EFFORTS. LOCATIONS FAILING TO MEET THE GEO-TECHNICAL ENGINEER'S REQUIREMENTS SHALL BE RE -COMPACTED AND RETESTED AT THE CONTRACTOR'S EXPENSE, AND AS DIRECTED BY THE ARCHITECT. WRITTEN CERTIFICATION THAT THE MINIMUM DESIGN BEARING CAPACITY, AND THAT THE COMPACTION REQUIREMENTS HAVE BEEN MET SHALL BE MADE BY THE GEO-TECH. ENGINEER. CONCRETE: CONCRETE SHALL ACHIEVE MINIMUM28 DAY COMPRESSIVE STRENGTHSASFOLLOWS: 2,500 PSI REGULAR WEIGHT FOR FOOTINGS, AND SLAB -ON -GRADE 3,000 PSI REGULAR WEIGHT FOR BEAMS, COLUMNS;: AND 5" STRUCTURAL TERRACE SLAB. CONTRACTOR SHALL SUBMIT PROPOSED MIX DESIGNS, WITH HISTORICAL STRENGTH DATA FOR EACH SEPARATE MIX PRIOR TO CONCRETE PLACEMENT. CONCRETE SLUMP SHALL NOT EXCEED 5" +1- PRIOR TO THE ADDITION OF PLASTICIZER, CONCRETE SHALL COMPLY WITH ALL THE REQUIREMENTS OF ACI 301 AND ASTM C-94 OR MEASURING, MIXING, TRANSPORTING, ETC. CONCRETE TICKETS SHALL BE TIME -STAMPED WHEN CONCRETE IS BATCHED. THE MAXIMUM TIME ALLOWED FROM WHEN WATER IS ADDED TO THE MIX UNTIL IT IS DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED 90 MINUTES. IF FOR ANY REASON THERE IS A DELAY IN SUCH THAT A BATCH IS HELD FOR LONGER THAN 90 MINUTES, THE CONCRETE SHALL NOT BE PLACED, IT SHALL BE THE RESPONSIBILITY OF THE TESTING LABORATORY TO NOTIFY THE OWNER'S REPRESENTATIVE AND THE CONTRACTOR OF ANY NON COMPLIANCE WITH THE ABOVE REQUIRED CONCRETE COVERAGE OVER REBAR SHALL BE AS FOLLOWS: A. 3" FOR CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH (FOUNDATIONS): B, FOR CONCRETE E{POSED TO EARTH AND/OR WEATHER: MIT FOR #5 A JD SMALLER T FOR.#6 AND .ARGER C. FOR CONCRETE NOT EXPOSED TO WEATHER 3/4" FOR SLABS, WALLS AND JOISTS 1-112" FOR BEAM AND COLUMN PRIMARY REINFORCEMENT, TIES, STIRRUPS TYPE "M"OR"S" MORTAR SHALL BE USED EXCLUSIVELY ON. THIS PROJECT. MORTAR SHALL BE PROPORTIONED AND MIXED AS. OUTLINED UNDER ASTM C-270. HORIZONTAL AND VERTICAL MORTAR JOINTS SHALL BE 3/8" THICK UNLESS OTHERWISE NOTED. REMOVE MORTAR PROTRUSIONS THAT EXTEND INTO CELLS TO BE FILLED. FILL CMU CELLS SOLID WITH GROUT AT ALL CELLS TO RECEIVE EXPANSION ANCHORS AND/OR VERTICAL REINFORCING. LAP VERTICAL REBAR 6 X BAR NO. (48 BAR DIAMETERS)., U.N.O. STRUCTURAL STEEL: THE MATERIAL, FABRICATION, AND ERECTION OF STRUCTURAL STEEL SHALL COMPLY WITH THE SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS, 9TH EDITION, BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION. STRUCTURAL STEEL SHALL BE ASTM A36, Fy = 36 ksi FOR ANGLES, PLATES, AND W-SHAPES. STRUCTURAL TUBING SHALL BE ASTM A-500, GRADE B, Fy - 46 ksi. STRUCTURAL PIPE SHALL BE ASTM-53, GRADE B, TYPE E OR S, Fy = 35 ksi. TUBE AND PIPE COLUMNS SHALL BE CONCRETE -FILLED IN THE SHOP. ANCHOR BOLTS AT THE COLUMN BASES SHALL BE ASTM A307 BOLTS WITH DOUBLE -NUT LEVELING. ALL OTHER BOLTS SHALL BE ASTM A325-N BOLTS WITH WASHERS UNDER THE TURNED ELEMENT. BOLTS SHALL BE TIGHTENED IN ACCORDANCE WITH THE TURN -OFF -THE -NUT METHOD. ALL ANCHOR BOLTS SHALL BE GALVANIZED STEEL. J-BOLTS ARE TO BE STEEL. D ERECTION PLAN SHOWING COMPONENT LAYOUT. SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY A FLORIDA LICENSED PROFESSIONAL ENGINEER. THE HURRICANE STRAPS SPECIFIED ON THE WALL SECTIONS AND PLANS ARE PROVIDED TO FACILITATE THE CONSTRUCTION SCHEDULE, AND MAY CHANGE PREDICATED ON THE TRUSS AND GIRDER REACTIONS PROVIDED BY THE TRUSS ENGINEER. THE TRUSS TO STRUCTURE CONNECTIONS AND LOADS SPECIFIED ON THIS PLAN SHALL SUPERCEDE THOSE OF THE DELEGATED TRUSS ENGINEER. WIND UPLIFT VALUES HAVE BEEN BASED ON ASCE 7-10 COMPONENT AND CLADDING WIND LOAD PRESSURES. THE DELEGATED TRUSS ENGINEER SHALL BE RESPONSIBLE FOR ALL TRUSS TO TRUSS CONNECTIONS. ALL SHEET METAL FRAMING CONNECTORS SHOWN ON THE PLANS SHALL BE "USP STRUCTURAL CONNECTORS" BY USP, OR EQUAL UNLESS NOTED OTHERWISE ON PLANS, INSTALL CONNECTIONS WITH THE SIZE AND NUMBER OF BOLTS/NAILS AS RECOMMENDED BY THE MANUFACTURER IN THE LATEST CATALOG. "EWED FOR COMPLIANCE IE//++COUN"' Y -3OCC FILE COPY FASTENER SCHEDULE WINDOW AND DOOR BUCK FASTENERS FASTENER APPLICATION SIZE TYPE _ SPACING REMARKS PLICATION SIZE TYPE SPACING REMARKS 1.2 PT FURRING TO CASE HARDENED COIL 8 OIC E DOOR BUCK MASONRY/CONC. NAIL 1 1/2" LONG. SONRY/CONC. rlGARAGE SEE DETAIL SEE DETAIL SEE DETAIL SEE DETAIL SOD, AL. EXT. DOORS CASE HARDENED COIL 9" O,C WINDOW,IDOORI FASTENED DOOR BUCK ix PT, SEE NOTE 6 NAIL 1 14'Z' LONG. STAGGERED INTO MASONRY/GONG. SONRY.'CONC. SEE DETAIL SEE DETAIL SEE DETAIL SEE DETAIL WINDOW BUCK CASEHARDENED COIL 91 01C WINDOW/DOOR/FASTENED METAL STRAP TO CONTACT THIS ENGINEER FOR SPACING Ix PT, SEE NOTE NAIL 11!2"LONG. STAGGERED INTO MASONRY/GONG. MASONRYICONC. — REQUIREMENTS EXT. SWING DOOR (2)3116'DIA. 'TAPCON- 11;2"EMBED,8-END. NON -BEARING WOOD 1,"2"° iwolc EXPANSION 2+P O/C BUCK 2x PT, SEE NOTE 6 NO WASHER FASTNER DIST., 1 1/2"EDGE DIST. WALL TO CONC. SLAB W/ WASHER L 4'EMBED. 4"END BOLT DIST.. 3" EDGE DIST. 2x PT WINDOW BUCK O.i38' PAP x 2 VS- 9" O/C 4" END. DIST., 1 1/2" PT TO STEEL COL., SEE W/ WASHER STAGGERED EDGE DIST. NOTE 6 NOTES 1. STAPLES SHALL NOT BE USED FOR ANY STRUCTURAL APPLICATIONS 2. FASTENING OF GARAGE DOORS, WINDOWS AND EXTERIOR SWING DOORS TO FRAMING BUCKS SHALL BEAS PER MANUFACTURER'S SPECS AND I OR NOA 3. ALL FASCIA MATERIAL SHALL BE HAND FRAMED 4. PAF SHALL BE HILTI X-ZF HEAVY DUTY PINS OR EQUAL SAME DIAMETER AS SPECIFIED HEREIN 5. FASTENER SPACING FOR THE BUCKS SHALL BE THE STRICTER REQUIREMENT OF THE NOA OR THE SPACING DETAILED ABOVE 6. WINDOW AND DOOR BUCKS SHALL BE AS WIDE OR WIDER AS THE DOOR OR WINDOW FRAME EXPECT FOR AN EXTERIOR SWING DOOR WITH A WOOD,DOOR FRAME. lx MEMBERS ARE NAILED AND 2x MEMBERS ARE SECURED W7 TAPCONS OR PAF TO THE SUBSTRATE, 551 S. APOLLO BLVD. MELBOURNE, FL 32901 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F W h 1I U W O 64 y R v W 4 F A SUSDIV. 8e LOT: CREEKSIDE LOT 70 PROJECT# 4321.000 070Rl MODEL: 4EAB "1672-ARIA" GARAGE SWING: LEFT PAGE: DETAILS 60 MPH EXP. 00 ARCHITECT- STATE OF FLORIDA MICHAEL C. ANDERSON AR NO 17305 DATE: 08/5/19 SCALE: 1/4"- f — O" SHEET S�T � V I Planning & Development Services Department �COUNTY Building & Regulations Division Product Review Affidavit FL # or Miami -Dade FLORIDA PRODUCT OMPI�1ANQ`E_ COUN I I OCRE FILE COPY REVISION EXPIRATION product Model # Manufacturer Glass Description Method of Attachment Building Design Product Design APPROVAL REVISION DATE Pressure Pressure 1/4" concrete screw 6" edge distance @head, 4" edge distance @jamb, 4" each side of transom centerline to bucking. Fastener spacing @ 15" o/c max. @head and jamb. FL5891.2 R6 12/31/2021 Swing door Smooth Star Thermo-Tru N/A Min. embedment of all anchors to be 11/4" (+36) / (-47) (+67) / (-67) Type 1: 3/16" or 1/4" ELCO Ultracon anchor 6" max. from corners, 113/4" o/c atjamb, 16" @ head. 11/4" embedment. Type II: 3/16" or 1/4" ITW concrete tapcon anchor: 6" max, from corners, 7 1/4" o/c atjamb, 101/4" @ head. 11/4" embedment. Two additional tapcons midspan and one at lower frame required vertically each side. FL16103.1 R12 4/30/2020 SH Window Ply Gem 1500 Ply Gem Non Impact Install per manufacturers recommended requirements. (+38) / (-48) (+50) / (-50) Type 1: 3/16" or 1/4" ELCO Ultracon anchor 6" max. from corners, 14" o/c atjamb, 10" @ head. 11/4" embedment. Type II: 3/16" or 1/4" ITW concrete tapcon anchor. 6" max. from comers, 81/2" o/c atjamb, 6" @ head. 11/4" embedment. Eight additional tapcons top and bottom required horitontally, one midspan vertically each FL16100.1 IRS 6/30/2020 Vertical Mullion Ply Gem 1500 Ply Gem Non Impact side. Install per manufacturers recommended requirements. N/A N/A Type 1: 3/16" or 1/4" ELCO Ultracon anchor 6" max. from corners, 14" o/c atjamb, 16" @ head / sill. 11/4" embedment. Type II: 3/16" or 1/4" ITW concrete tapcon anchor. 6" max. from comers, 8 1/2" o/c atjamb, 101/2" @head / sill. 11/4" embedment. Five additional tapcons top and bottom required horitontally,two midspan vertically FL16104.2 RS 11/30/2022 Fixed Window Ply Gem 1500 Ply Gem Non Impact each side. Install per manufacturers recommended requirements. (+38) / (-48) (+55) / (-55) 1/4" concrete tapcon anchor. 2 1/2" minimum edge distance. 6" max o/c from corners Builders Series 4780 w/ and 20 3/4" max o/c elsewhere top, vertically and bottom. 2 1/2" min embedment. FL14634.1 R3 12/31/2019 Sliding Glass Door Ply Gem Non Impact (+33) / (-41) (+50) / (-50) Sill Riser 1/4" concrete screw 6" edge distance @head, 4" edge distance @jamb, 4" each side of transom centerline to bucking. Fastener spacing @ 15" o/c max. @head and jamb. FL20461.17 R4 12/31/2019 Opaque single Smooth Star Thermo-Tru N/A Min. embedment of all anchors to be 11/4" +36 ( ) / (-47) +47 ( ) / (-47) door with transom Double Garage 3/8" x 2-3/4" Hilti sleeve anchors 6" from ends 22" 0/C FL16107.3 R10 12/31/2020 551 S. APOLLO BLVD., SUITE 202 MELBOURNE, FLORIDA32901 PH: 321-802-3591 www.abd esigngroup.com AA #: 0003325 LLI W W 0 � Q � Ca o � � O (Y q z O u h m O =9 r LE-� LiLLI 9VHD1V. de LOT: ST LUCIE COUNTY MASTER PA 1�ROJECT* WOZiE? i EXPRESS SHINGLE GARAGE 971TlNG: PAGE: 160 MPH EXP. C ARCHITECT STATE OF FLORIDA IC HAEL C. ANDERSON AR NO 17305 � ` 07 16 19 DATE: I SCALE: 1/4"=1'-0" 1 SITMET Q L 1I