HomeMy WebLinkAboutPLANS*CONTRACTOR TO VERIFY LOCATION OF ALL UTILITIES AVAILABLE AT SITE BEFORE PROCEEDING W/ CONSTRUCTION. *CONTRACTOR, SUBCONTRACTOR, MATERIAL SUPPLIER, ETC. SHALL MAKE THEMSELVES FAMILIAR WITH THE CONTRACT DOCUMENTS AND SHALL VERIFY ALL DIMENSIONS, CONDITIONS AT JOBSITE, PLANS, SPECIFICATIONS, ETC. AS APPLICABLE AND REPORT ANY DISCREPANCIES, ERRORS OR OMISSIONS TO THE ARCHITECT PRIOR TO ANY WORK BEING PERFORMED. OTHERWISE, THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR ANY ERRORS AND THE CONTRACTOR, SUBCONTRACTOR, MATERIAL SUPPLIER, ETC. SHALL ASSUME FULL RESPONSIBILITY FOR ERRORS AND/OR DELAYS AND CORRECT THEM AT THEIR OWN EXPENSE. LANCE A VOGL SHALL NOT BE LIABLE FOR ANY LOSS, DAMAGE OR INCONVENIENCE ARISING FROM INACCURACIES. *THE ARCHITECT HAS NOT BEEN RETAINED FOR THE SUPERVISION OR THE ADMINISTRATION OF THE EXECUTION OF THE WORK OF THIS PROJECT. *EACH CONTRACTOR SHALL BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES FOR SAFETY PRECAUTIONS AND SHALL COMPLY WITH THE REQUIREMENTS OF O.S.H.A, APPLICABLE BUILDING CODES, AND ALL GOVERNMENTAL AGENCIES HAVING JURISDICTION. *EACH CONTRACTOR SHALL MAKE ALL ARRANGEMENTS FOR, OBTAIN AND PAY FOR ALL PERbIITS, TESTS, INSPECTIONS, AND APPROVALS REQUIRED FOR HIS PORTION OF THE WORK *CAULKING USING A ONE -PART URETHANE PRODUCT SHALL BE APPLIED AT ALL JUNCTIONS OF WALL AND WINDOW AND DOOR FRAMES WITH ABUTTING WALL SURFACES TO PROVIDE A WEATHERTIGHT, WATER-RESISTANT INSTALLATION. *CONTRACTOR(S) TO COORDINATE WALL BLOCKING REQUIREMENTS W/ CABINETRY AND SHELVING LOCATIONS. *ALL WOOD IN CONTACT WITH MASONRY TO BE PRESSURE TREATED SYP MEETING AWPA STANDARDS TO A MINIMUM 0.4 PCF RETENTION. ALL METAL CONNECTORS, NAILS, & SCREWS IN CONTACT WITH PRESSURE TREATED LUMBER SHALL BE HOT -DIPPED GALVANIZED AND CONFORM TO ASTM STANDARDS. CONCRETE: *SHALL MEET A MINIMUM COMPRESSIVE STRENGTH OF 3000PSI @ 28 DAYS. *SLUMPS SHALL BE 4" MIN AND 6" MAX. *MIN 3% AIR ENTRAINMENT. *MAX WATER/CEMENT RATIO OF 0.55. REINFORCING: *SHALL MEET ASTM STANDARDS FOR 60 GRADE. *ALL REINFORCING STEEL SPLICES SHALL BE LAPPED A MINIMUM 40 BAR DIAMETER ALL HOOKED REINFORCING BARS SHALL HAVE AN EXTENSION OF 12 BAR DIAMETERS BEYOND BEND. *ALL OUTER BARS IN FOOTERS SHALL HAVE CORNER BARS WITH A MINIMUM 40 BAR DIAMETER LAP. ALL FOOTER BARS SHALL HAVE A MIN. 3" CONC. COVER WHERE THE CONC. IS CAST AGAINST EARTH, OR 1r1111 WHERE CONC. IS FORMED AND EXPOSED TO EITHER WEATHER OR EARTH. WOOD: *ALL LOAD BEARING STUDS TO BE: #2 SOUTHERN YELLOW PINE, #2 DOUGLAS FIR -LARCH, #2 SPRUCE -PINE -FIR, OR BETTER. GENERAL SITE NOTES: CONTRACTOR TO HAVE CERTIFIED FLORIDA SURVEYOR LAYOUT BUILDING ON LOT TO ASSURE THAT NO SETBACKS OR EASEMENTS ARE ENCROACHED AND TO VERIFY LOCATIONS OF EXISTING/ADJACENT, WELLS, SEPTIC SYSTEMS, AND TREES. THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR EXISTING CONDITIONS ON THE LOT INCLUDING, BUT NOT LIMITED TO, HAZARDOUS MATERIALS, UNSTABLE SOIL, OR ANY OTHER UNFORESEEN CONDITION. IMMEDIATELY PRIOR TO REINFORCING STEEL PLACEMENT, ALL BEARING SURFACES OF ALL FOOTINGS AND FLOOR SLAB AREAS SHALL BE COMPACTED USING HAND OPERATED MECHANICAL TAMPERS. ALL LOCALIZED AREAS WHICH HAVE BEEN LOOSENED BY EXCAVATION OPERATIONS SHALL BE ADEQUATELY RE -COMPACTED. POSITIVE DRAINAGE SHALL BE MAINTAINED AT THE SITE DURING CONSTRUCTION. REMOVE FREE WATER FROM EXCAVATIONS BEFORE CONCRETE. 11 MINIMUM SOIL BEARING CAPACITY SHALL BE 2500 PSF. N 1 SITE PLAN 3/32 —P-0" INDEX OF DRAWINGS Al PROPOSED SITE PLAN & PROJECT DATA aecEtvED A2 FLOOR PLAN, ELECTRICAL PLAN & ELEVATIONS 1t11a A3 FOUNDATION PLAN, ROOF FRAMING PLAN & DETAILS Npy' 2 vrl st, lU SCOPE OF WORK 1. NEW DETACHED POOL CABANA ADJACENT TO EXISTING POOL. AREA CALCULATIONS PROPOSED COVERED POOL CABANA............................................................551 S.F. *ALL AREAS CALCULATED TO OUTSIDE DIMENSIONS LOT COVERAGE LOT SIZE (PER S.L.C. TAX RECORDS)............................................................25,700 S.F. (.59 ACRES) PROPOSED BUILDING COVERAGE...............................................................4,362 S.F. (17%) PROPOSED TOTAL IMPERVIOUS......................................................................7,638 S.F. (30%) PROPOSED TOTAL OPEN SPACE.....................................................................70% DATA &DESIGN PRESSURE SCHEDULE LWIND LOADS BASED ON 2017 FLA. BUILDING CODE 2. TYPE OF CONSTRUCTION: CBS 3. BUILDING DESIGN: OPEN 4. WIDTH OF END ZONE: 4' 5. ULTIMATE WIND SPEED: 160 MPH 3 SECOND GUSTS 6. BUILDING CATEGORY: II 7. BUILDING MEAN HEIGHT: 131011 8. EXPOSURE CATEGORY B 9. ADJUSTMENT COEFFICIENT: 1.0 10, COMPONENTS & CLADDING WIND PRESSURE ON: 10A: ROOF ZONE: 1) +13.1 / -20.8 2) +13.1 / -36.1 3) +13.1 / -53.4 10B: WALL ZONE: 4) +22.7 / -24.6 5) +22.7/ -30.4 1OC:GARAGE DOOR:— _r„� 6) N/A SC BNNED t;t I uriai':npontV � T REV EWER FOR CODE COMPLIANCE ST. LUCIE CO Tl°.(��JIoj BOCC t I� J z J C) \I W CP% Z Q H N LLJ 0 O U- .J U- C3 C) cn D N w V) I Q vi U Q t`. (8) CN (y) U L d' 0 00 I`e E a O ICI OF FLOC, f .O ;E A. VOGQ AR96414 L.� PROPOSED SITE PLAN & PROJECT DATA PROJECT NO.t HUNTER I DRAWN BY, LV DATE, 2.1.19 REVISIONSi Q 11/20/19 PERB.D. SHEET NO. VA DocuSian Envelooe ID: DD3FC77C-A184-4CD1-BB5E-164AA42401C3 J EXISTING HOUSE SERVICE LOADS EXIST. 5284 SQ/FT(@ 3 WATTS/SF) APPLIANCE CIR.(2 @ 1500 EACH) LAUNDRY CIR. (1 @ 1500 EACH) OVEN RANGE EXHAUST HOOD DISHWASHER DISPOSAL MICROWAVE WATER HEATER REFRIGERATOR WASHER DRYER POOL PUMP ELECTRIC POOL HEATER IRRIGATION PUMP SUB -TOTAL TOTAL PANEL LOAD: HVAC #1(9.5kw HEATSTRIP) HVAC #2(9.5kw HEATSTRIP) 1ST 10,000VA @ 100% REMAINING @ 40% TOTAL EXISTING SERVICE: TOTAL AMPS: NEW CABANA SERVICE LOADS =15,852 WATTS GENERAL LIGHTING =1,000 WATTS =3,000 WATTS GFI APPLIANCE CIR. =1,500 WATTS =1,500 WATTS U.C. REFRIGERATOR =1,200 WATTS =1,500 WATTS GAS FIREPLACE IGNITER =1,200 WATTS -5,000 WATTS =500 WATTS CABANA SUB -TOTAL =4,900 WATTS =1,500 WATTS =1,500 WATTS NEW SUB-TOTAL =56,952 WATTS =2,000 WATTS =3,000 WATTS TOTAL PANEL LOAD: =1,500 WATTS HVAC #1(9.5kw HEATSTRIP) =9,500 WATTS =1,500 WATTS HVAC #2(9.5kw HEATSTRIP) =9,500 WATTS =5,000 WATTS 1ST 10,000VA @ 100% =10,000 WATTS =2,200 WATTS REMAINING @ 40% =18,781 WATTS =5,000 WATTS =1,500 WATTS TOTAL COMBINED SERVICE: =47,781 WATTS =52,052 WATTS /240V TOTAL AMPS: =199 AMPS =9,500 WATTS =9,500 WATTS EXISTING METER/SERVICE: =320 AMPS =10,000 WATTS (*CONTRACTOR TO FIELD VERIFY & NOTIFY =16,821 WATTS ARCHITECT IF EXISTING SERVICE IS 200 AMPS OR LESS) =45,821 WATTS /240V =191 AMPS *NOTE: CALCULATED LOADS ARE BASED ON GENERAL EQUIPMENT LOAD REQUIREMENTS. ELECTRICAL CONTRACTOR TO VERIFY & ADJUST ALL LOADS, WIRE SIZE & BREAKER SIZE WITH EQUIPMENT MANUFACTURERS SPECIFICATIONS PRIOR TO INSTALLATION. I N PROFILE ELEVATION FYPON BKT8X29X4 (MATCH EXIST. HOUSE TRIM COLOR) - ELECTRICAL NOTES: *ELECTRICAL CONTRACTOR SHALL COMPLY WITH 2O14 N.E.C. AND ALL OTHER APPLICABLE CODES. *ELECTRICAL CONTRACTOR SHALL VERIFY ALL ELECTRICAL LOADS, RISER DIAGRAM, PANEL SCHEDULE & ELECTRICAL PLAN & NOTIFY THE G.C. OF ANY ERRORS OR DISCREPENCIES PRIOR TO INSTALLATION. *ELECRICAL CONTRACTOR IS TO SIZE BRANCH CIRCUITS. A MAXIMUM VOLTAGE DROP OF 3 PERCENT IS PERMITTED. *ALL OUTLETS, SWITCHES/DIMMERS, AND LIGHT FIXTURE LOCATIONS TO BE VERIFIED BY OWNER ON WALK-THRU WITH ELECTRICAL CONTRACTOR *ALL DEVICES SHALL BE SMOOTH TYPE (WHITE) UNLESS OTHERWISE NOTED. *ALL RECEPTACLES INSTALLED OUTDOORS, BATHROOMS, GARAGE, LAUNDRY, AND KITCHENS TO HAVE GROUND FAULT CIRCUIT INTERRUPTER BRANCH CIRCUITS THAT SUPPLY *ALL 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUN -ROOMS, RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED PER NEC 210.12.*PROVIDE/INSTALL TAMPER -RESISTANT RECEPTACLES IN ALL AREAS AS SPECIFIED BY NEC 210.52. *VERIFY ALL CONDUCTORS AND BREAKERS W/ EQUIP. MANUF. SPECS. *ALL ELEC. SWITCHES SHALL BE 48" A.F.F. AND ALL RECEPTACLES SHALL BE 12" A.F.F. UNLESS OTHERWISE NOTED. *ALL ELECTRICAL DEVICES LOCATED IN NON -CONDITIONED SPACE TO BE OUTDOOR "WEATHER RESISTANT" RATED. ALL ELECTRICAL FIXTURES LOCATED IN NON -CONDITIONED SPACE SHALL BE MARKED "SUITABLE FOR WET LOCATION" OR "SUITABLE FOR DAMP LOCATION". *ELECTRICAL CONTRACTOR SHALL PROVIDE DISCONNECTS AT ALL EQUIPMENT (WATER HEATER, A/C UNITS, AND ANY OTHER EQUIPMENT AS REQUIRED BY N.E.C. 440.14.) *A MINIMUM OF 75% OF LAMPS INSTALLED SHALL BE HIGH EFFICACY LAMPS. ELECTRICAL LEGEND 110 VAC DUPLEX OUTLET $ LIGHT SWITCH LIGHT FIXTURE 110 VAC DUPLEX OUTLET $... THREE/FOUR-WAY LIGHT SWITCH (Recessed) UNDER -COUNTER LIGHT (1 /2-switched) n I 4 110 VAC DUPLEX OUTLET DIMMER SWITCH o STEP LIGHT 4D FLOOD LIGHT WR (GFI-ground fault interrupt) I Ds DOOR SWITCH (MOTION SENSOR) (OUR=weather resistance rated) FLOOR OUTLET { LIGHT FIXTURE FLOURESCENT FIXTURE (owner to approve location) (Ceiling -Mounted) (WP = Weatherproof) * Refer to Manufacturer's Specifications (Height/Voltage) I LIGHT FIXTURE (Wall -Mounted) CEILING FAN Xw/ht) ELECTRICAL PANEL �-- LIGHT FIXTURE (Pendant/Chandelier) ELECTRICAL METER EXH. FAN EXH. FAN/LIGHT GAS LINE DB DOORBELL ® CABLE/DATA RECEPTACLE s� SMOKE/CARBON DETECTOR �n GARAGE DOOR OPENER 1 FRONT E ELEVATION 1/4"=V-0" 3 REAR (S ELEVATION AZ 1/4"=1'-0" tu 10' 0 (TOP OF BEAM) 06 0' 0" (T.O.S.) 910' 0" (TOP OF BEAM) 0" (T.O. 2 SIDE AZ 1/4"=1'-0" ELEVATION SIDE (SE) ELEVATION 1/4"=1'-0" 0 ... HOOD TO BE - CENTERED OVER O I HOOD GRILL (LOW PROFILE R CEILING MOUNT) � I _ 3V CA& l i0I TN%SIL 9NK I IRFf11l O N�NR I REIRAE- C.H. I ---- !- -- ---- - - / li I R lii I / I, --------- ------------ N 5 ELECTRICAL PLAN A2 1/4°=V-0° COLUMN LEGEND CMU COLUMN (xSEE WALL SECTION) 16'-0' __--- ___________ I I 1 I oq �j v I C S I J� ]i CAB. I I I ReCYC. j o I I SYMBOLS: x WALL SECTION .1� ELE;VATION L e DETAIL BUILDING SECTION x HOSE BBB uI 01 I i PROPOSED POOL CABANA I I Fo I a F00 I I I I a' TV EXTEEOOR Ajl RATED RATED4 02"GAS FIXEPLACE I pl �I C'.84. TABLE 8.00- D. a FLOOR PLAN I �I I I II I II II I N j I � O z z REVIEWED FOR v ODE COMPLIANClad T. LUCIE COUNT E O N U W `- Oo-- M-� O v� Z Q) ~ @�)\ V o } Q L0 U Q `/ 6 D00_ON C4 3 =t�0 Q Lu U 9 Cn o O L 0 O OF FLOOR PLAN, ELECTRICAL PLAN & ELEVATIONS PROJECT NO., HUNTER I DRAWN BY, LV DATE, 2.1.19 REVISIONS, SHEET NO. A2 B" (min.) STUCCO SOFFIT (W/ —� CONTINUOUS VENT) OVER 8" GALV. RIB LATH ATTACHED W/ GALV. RINGSHANK NAILS OR SCREWS W/ A HEAD DIAMETER NOT LESS THAN 3" W/ 1 J" MIN. PENETRATION INTO HORIZONTAL WOOD FRAMING MEMBERS. (*MATCH HOUSE SOFFIT STUCCO FINISH) BEAM PER SCHEDULE MATCH EXISTING HOUSE STUCCO FINISH 12"xI2" CMU W/ 4 #5 VERT. BARS HOOKED TO FOOTING STONE CAP (*TO BE SELECTED BY OWNER) STONE VENEER (CULTURED STONE SOUTHERN LEDGESTONE IN FOG OR COUNTRY LEDGESTONE IN ECHO RIDGE OR APPROVED EQUIV.) *SCREEN TRACK TO BE RECESSED INTO STONE. COPPER "EGG" 30"Wx20"Hx48"D CAP W/ COPPER SCREEN (DIAMOND PATTERN) EACH END (CHIMNEY KING #30B%OR APPROVED EQ. *VERIFY CHIMNEY/CHIMNEY CAP SIZE/ STYLE/FINISH W/ OWNER) VENT -FREE GAS FIREPLACE /YB�ELOW. SEALED CHIMNEY CAP W/ NO PENETRATION. \ COPPER CHIMNEY CAP TERMINITE CHIMNEY 2FT MIN. FLASHING — ABOVE ROOF RIDGE — — I ° 8" POURED SOLID TOP COURSE W/ (1) #5 BAR CONT. 1 r_r ING PER 1 y0 r� �e B ROOF / CHIMNEY8" CMU ' 4 4 F' p I / FLASI POURED SOLID 1'All*;II ' 1 SE • I1�� 14 O. FLASHING TILE ROOF 512 �SIMPSON HGA10 EACH TRUSS SIMPSON HU212Z EACH TRUSS % %!�j�%!' ! �!� Ix6 T&G CEILING SIMPSON HU212Z EACH TRUSS 8"x8" LINTEL @ CHIMNEY OFFSET W/ (1) #5 BAR CONT. 1 CHIMNEY DETAIL A3 3/4°=1'-0" — - CONC. TILE ROOF (*MATCH EXISTING) ON PEEL-N-STICK UNDERLAYMENT ON 8" CDR PLYWOOD SHEATHING. ENGINEERED WOOD ROOF TRUSSES @ 24" O.C. W/ 51" TOP CHORD SEE TRUSS CONNECTION SCHD. FOR TIE -DOWN CONT. DRIP FLASHING OVER P.T.1x2, OVER 2x8 SMOOTH CEDAR FASCIA FIELD 12 VERIFY/MATCH EXISTING) 5 10' 0" T.D.B. e 2,-0" Li 4r 0' 0" T.O.S THICKENED SLAB EDGE 18" DEEP X 16" WIDE W/ (2) #5 BARS CONT. -1x6 T&G CEILING REMOVABLE HARDIE_PANE4 OR T&G FIpR SCREE9ftbIOTOR ACC& (*VERIFY W/ MANUF. SPECS & OWNER) RETRACTABLE SCREEN - AS SELECTED/APPROVED BY OWNER (INSTALL PER MANUF. SPECS) TYP. WALL SECTION 3/4"=1'-0" 6x6 16'-0' ---- ----------I--- 1--------I---- ---- -I�I- 2'-0' I i 2'-0' _ N1n 'I- -j�I�11 I I I O W — — — — — — — — = — — — — — — 1 — '--- —'— -- '—---'—'—' T-1— I I I N_ —.------- .—,— —,—. I 1 I I-1— I 0.l � I I 1 A3 I I I 1 5/12 5 12 I 1 1 I 1 I I I I I I I I L-1 3.5,12 CRICKET 1 J ZA I I m L1 1 I 1 0 I I I I I I I I i I I i I I I I I I I I I I �1 1 I I I I I _I_T 1� ------------- - - I F�Fi I I o I N N '2 ROOF FRAMING- PLAN A3 1/4`-P-0" CONCRETE BEAM / LINTEL SCHEDULE BEM ID SIZE REINFORCING STIRRUPS TIE & SPACING TOP OF WALL OR BEAM NOTES BOTTOM MIDDLE TOP B-1 8"x16" (1) #5 - (1) #5 10, 0" LINTEL BEAM (CASTCRETE OR APPROVED EQUAL I 1 UP TO CT W OPENINB 8"x8n 1 #5 () - - VERITYCHIMNEY PRE -CAST (CASTCRETE OR EQ.) OFFSET SHEATHING NAILING SCHEDULE ITEM NAIL: SIZE EDGE FIELD NOTES SPACING SPACING " CDX ROOF ZON11 L 2, & 3 (8d ROUND ZONE 1: 4" O.C. ZONE 1: 6" O.C. SHEATHING HEAD (RING SHANK) ZONE 2. 4" O.C. ZONE 2: 4" O.C. ZONE 3: 3" O.C. ZONE 3: 3" O.C. ROOF SHEATHING 8d ROUNDHEAD TJNG 4" O.C. N/A NAIL 2x FASCIA TO TRUSS TO TOP OF FASCIA SHANK) ENDS W/ (2) 16d NAILS (MIN.) 32' CDX WALL 8d 4" O.C. 6" O.C. SHEATHING *NOTE: SHEATHING NAIL SPACING SFLALL NEVER BE LESS THAN 3" O.C. ROOF SHEATHING NAILING ZONES " aO mfi e 2 ° Aa7l i0 0 a "m O O O a a a "e' = WIDTH OF END ZONE (*SEE. DATA AND DESIGN PRESSURES SCHEDULE SHEET Al) TRUSS CONNECTION SCHEDULE TYPICAL CONNECTION NOTES: ALL MEMBERS ARE ANCHORED TO CONCRETE BEAM WITH SIMPSON HHETA20 UNLESS NOTED OTHERWISE. ALL MEMBERS ARE ANCHORED TO FRAME WALLS WITH (2) SIMPSON HTS20 UNLESS NOTED OTHERWISE ON LAYOUT. TRUSS ID SIMPSON CONNECTOR ID FASTENERS MAX ALLOWED UPLIFT NOTES TRUSS TO CONC. BEAM HETA20 PER MANUF. SPECS 1810 GIRDER TO CONC. BEAM HETA20 PER MANUF. SPECS 1810 (EACH) (2) EACH GIRDER END NOTES: - - - - -TRUSS DRAWINGS TO BE PROVIDED TO THE ARCHITECT BY THE TRUSS MANUFACTURER FOR REVIEW PRIOR TO RELEASE OF FINAL SIGNED AND SEALED TRUSS DRAWINGS. -TRUSS MANUFACTURER IS RESPONSIBLE FOR FINAL LAYOUT, SPANS, & ALL TRUSS & HEADER ENGINEERING. -TRUSS MANUFACTURER TO INDICATE UPLIFT REACTIONS @ TRUSS/GIRDER ENDS & PROVIDE HANGER CALLOUTS FOR TRUSS TO GIRDER & GIRDER TO GIRDER CONNECTIONS. TRUSS MANUFACTURER TO NOTIFY THE ARCHITECT IF ANY UPLIFT REACTIONS EXCEED THE SPECIFIED VALUES ABOVE. -SIMPSON CONNECTORS SHALL BE ATTACHED PER MANUFACTURER STANDARDS. VERIFY WITH MANUFACTURER PRIOR TO INSTALLATION, -INSTALL MOISTURE BARRIER BETWEEN CONCRETE AND ALL NON PRESSURE -TREATED WOOD FRAMING. -SUBSTITUTION OF ANCHORAGE HARDWARE W/ EQUAL OR GREATER VALUES IS PERMITTED WITH APPROVAL FROM ARCHITECT. ARCHITECT ASSUMES NO RESPONSIBILITY FOR SUBSTITUTIONS WHICH DO NOT MEET THE LOAD REQUIREMENTS. 1 1,6'-0' 4. x$ GUT CONTROL JOINTS ("xl') AS SOON AS POSSIBLE AE ER TROWELING FILL JOINTS W/ LIQUID SEALER. I- — — — — — — — — --' — — - II I su�x �u rnmo�� I I THICKENED SLAB EDGE 18' DEEP X 4 16' WIDE W/ (2) A3 THICKENED SLAB 45 BARS CLINT. EDGE 18' DEEP X 36' WIDE W/ (4) corrrnoxmarr #5 BARS CONT, ewes I I S0' U" SLAB EATION �(nPAVERS ❑VERLEVSLAB TO BE .m B, LEVEL W/ EX.) o I ® £ . 4' THICK CONCSLAB WITH ip v A3 6x6 WWM OVER 6 MIL M VISQUEEN VAPOR BARRIER, i o r-s' OVER CLEAN, COMPACTED, TERMITE TREATED FILL. 9 HIM o Irll I I rnmaocOomT COLUMN SYMBOLS: 8"x8" GROUT FILLED CELL J WITH 1 #5 VERTICAL BAR 12"x12" CMU COLUMN WITH 4 #5 VERTICAL BARS. THICKENED SLAB o ® EDGE IS' DEEP X 16#5WBARS CONT. WALL SYMBOLS: ® FULL HT. WALL 40"H CMU WALL L INTERIOR WALL LOCATION 3 FOUNDATION PLAN N A3 1/4"=1'-0" - oll- PLUMBING LEGEND VENT PIPING O STUDOR VENT (S.V.) 1 ROOF VENT CA. CLEAN OUT PLUMBING NOTES, & ALL WORK SHALL COMPLY WITH 2O17 FLORIDA PLUMBING CODE, 2017 FLORIDA GAS CODE, AND ANY OTHER APPLICABLE CODES, B. PLUMBING PIPING & VALVES -COPPER TYPE 'K" PIPING AND FITTING BELOW SLAB. -COPPER TYPE "L" PIPING AND FITTINGS ABOVE SLAB. -LEAD FREE SOLDERED JOINTS, -SCHEDULE 40 PVC SANITARY SEWER & VENTS. CVENT TO REAR OF STRUCTURE D. CONTRACTOR TO VERIFY ALL PIPE SIZES/SPECS PER EQUIPMENT AND APPLICABLE CODE, E. CONNECTION TO EQUIPMENT SHALL BE VERIFIED WITH MANUF.'S CERTIFIED DRAWINGS, F. BEFORE FABRICATION, VERIFY AND COORDINATE ALL DIMENSIONS IN FIELD. G. ALL EQUIPMENT SHALL BE SUPPORTED AS REQUIRED TO PROVIDE A VIBRATION FREE, RIGID INSTALLATION. H, PROVIDE WATER HAMMER ARRESTORS AT EACH BRANCH LINE. I. SEE FLOOR PLAN FOR HOSE BIB LOCATIONS 2" SINK TO SEPTIC W/DISP. �\ 3" I '" &DISH. S. V. POOL CABANA 5 PLUMBING RISER A N,T S U) z E 1 rf1 0 RECENEz J D U z 21019 0 } Perm, ntV Ll J a- 5t. Luc(e W .0 �-- = U I- i i •O U 0 C 0 O, 0) W �..� 0 Z U Q to @� O �1 � U < III uLO Q on 0 UN tt ) f-' < ` Lu U z 4-O U O N u- C*4 t�- O O U a z z > 0)z 0 z U) uJ U 0 z Q -_ Q t� OF FL0 ;'LANCE A. VOGQ AR96414 ' U I-- �T- --------- RED AR vl z 0 U O lv W Ll LL�+ < (IJ ((� Q Q _J LLJ zId O Z cz FOUNDATION/ F ROOF FRAMING z PLAN & DETAILS Q I-- U REVIEWED FOR Q PROJECT NO.t HUNTER 1 CODE COMPLIANCE Uf� DRAWN BY, LV ST. LUCIE COUNTY z 0 DATE, 2.1.19 BOCC U REVISIIDN& Al 11/20/19 PERB.D. U I1J _ SHEET NO. '00�r zA3 Q Q DocuSign Envelope ID: 451BE5FD-5482-404D-B442-6552725E7DC8 EXISTING HOUSE SERVICE LOADS NEW CABANA SERVICE LOADS EXIST. 5284SQ/FT(@ 3 WATTS/SF) 15,852 WATTS GENERAL LIGHTING =1,000 WATTS APPLIANCE CIR.(2 @ 1500 EACH) =3,000 WATTS GFI APPLIANCE CIR. =1,500 WATTS LAUNDRY CIR. (1 @ 1500 EACH) =1,500 WATTS U.C. REFRIGERATOR =1,200 WATTS OVEN =1,500 WATTS RANGE =5,000 WATTS EXHAUST HOOD =500 WATTS DISHWASHER =1,500 WATTS DISPOSAL =1,500 WATTS MICROWAVE =2,000 WATTS WATER HEATER =3,000 WATTS REFRIGERATOR =1,500 WATTS WASHER =1,500 WATTS DRYER =5,000 WATTS POOL PUMP =2,200 WATTS ELECTRIC POOL HEATER =5,000 WATTS IRRIGATION PUMP =1,500 WATTS SUB-TOTAL =52,052 WATTS TOTAL PANEL LOAD: HVAC #1(9.5kw HEATSTRIP) 1 =9,500 WATTS HVAC #2(9.5kw HEATSTRIP) =9,500 WATTS 1ST 10,000VA @ 100 %=10,000 WATTS EXISTING METER/SERVICE: =320 AMPS REMAINING @ 40%=16,821 WATTS (*CONTRACTOR TO FIELD VERIFY & NOTIFY ARCHITECT IF EXISTING SERVICE IS 200 AMPS OR LESS) TOTAL EXISTING SERVICE:=45,821 WATTS /240V TOTAL AMPS: =191 AMPS *NOTE: CALCULATED LOADS ARE BASED ON GENERAL EQUIPMENT LOAD REQUIREMENTS. ELECTRICAL CONTRACTOR TO VERIFY & ADJUST ALL LOADS, WIRE SIZE & BREAKER SIZE WITH EQUIPMENT MANUFACTURERS SPECIFICATIONS PRIOR TO INSTALLATION. N N 1 I nJ to PROFILE ELEVATION FFYPON BKT8X29X4 (MATCH EXIST. HOUSE TRIM COLDR) ELECTRICAL NOTES: *ELECTRICAL CONTRACTOR SHALL COMPLY WITH 2O14 N.E.C. AND ALL OTHER APPLICABLE CODES. *ELECTRICAL CONTRACTOR SHALL VERIFY ALL ELECTRICAL LOADS, RISER DIAGRAM, PANEL SCHEDULE & ELECTRICAL PLAN & NOTIFY THE G.C. OF ANY ERRORS OR DISCREPENCIES PRIOR TO INSTALLATION. *ELECRICAL CONTRACTOR IS TO SIZE BRANCH CIRCUITS. A MAXIMUM VOLTAGE DROP OF 3 PERCENT IS PERMITTED. *ALL OUTLETS, SWITCHES/DIMMERS, AND LIGHT FIXTURE LOCATIONS TO BE VERIFIED BY OWNER ON WALK-THRU WITH ELECTRICAL CONTRACTOR. *ALL DEVICES SHALL BE SMOOTH TYPE (WHITE) UNLESS OTHERWISE NOTED. *ALL RECEPTACLES INSTALLED OUTDOORS, BATHROOMS, GARAGE, LAUNDRY, AND KITCHENS TO HAVE GROUND FAULT CIRCUIT INTERRUPTER. BRANCH CIRCUITS THAT SUPPLY *ALL 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUN -ROOMS, RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED PER NEC 210.12.*PROVIDE/INSTALL TAMPER -RESISTANT RECEPTACLES IN ALL AREAS AS SPECIFIED BY NEC 210.52. *VERIFY ALL CONDUCTORS AND BREAKERS W/ EQUIP. MANUR SPECS. *ALL ELEC. SWITCHES SHALL BE 48" A.F.F. AND ALL RECEPTACLES SHALL BE 12" A.F.F. UNLESS OTHERWISE NOTED. *ALL ELECTRICAL DEVICES LOCATED IN NON -CONDITIONED SPACE TO BE OUTDOOR "WEATHER RESISTANT" RATED. ALL ELECTRICAL FIXTURES LOCATED IN NON -CONDITIONED SPACE SHALL BE MARKED "SUITABLE FOR WET LOCATION" OR "SUITABLE FOR DAMP LOCATION". *ELECTRICAL CONTRACTOR SHALL PROVIDE DISCONNECTS AT ALL EQUIPMENT (WATER HEATER, A/C UNITS, AND ANY OTHER EQUIPMENT AS REQUIRED BY N.E.C. 440.14.) *A MINIMUM OF 75% OF LAMPS INSTALLED SHALL BE HIGH EFFICACY LAMPS. ELECTRICAL LEGEND 110 VAC DUPLEX OUTLET LIGHT SWITCH LIGHT FIXTURE 110 VAC DUPLEX OUTLET S 14 THREE/FOUR-WAY LIGHT SWITCH (Recessed) UNDER -COUNTER LIGHT (1 /2-switched) D DIMMER SWITCH uHU 110 VAC DUPLEX OUTLET' o STEP LIGHT aD ROOD LIGHT R (GFI-ground fault interrupt Ins DOOR SWITCH OTION SENSOR) ® (VUR=weather resistance rated) FLOOR OUTLET LIGHT FIXTURE FLOURESCEl) FIXTURE (owner to approve location) (Ceiling -Mounted) (WP = WeatheVroo fl Refer to Manufacturer's Specifications (Height/Voltage) LIGHT FIXTURE (Wall -Mounted) C! CEILING FAN (w/light) ELECTRICAL PANEL LIGHT FIXTURE (Pendant/Chandelier) ELECTRICAL METER EXH. FAN -K� EXH. FAN/LIGHT GAS LINE DB DOOR BELL ® CABLE/DATA RECEPTACLE �n GARAGE DOOR OPENER s� SMOKE/CARBON DETECTOR 1 FRONT (NE) ELEVATION A2 1/ t =1'-0° 10' 0" (TOP OF BEAM) 9 0' 0" (T.as.) 10- 0" (TOP OF BEAM) ., 0' 0" (T.D.S.) 2 SIDE A2) 1/4"=1'-0" ELEVATION 3 REAR (S ELEVATION 4 SIDE (SE) ELEVATION A2 i/ r'=1'-0" A2 1/4"=1'-0„ J (.-- CENTOERO OOVER # GRILL (LOW PROFILE (yR�) CEILING MOUNT) j HOOD 1 ...._ . Z RELk'C� lb CAB 24 FRIti4i fB G 5� 1 il- CRE (TRW/MR / TO II I� O SW1T0 * / RETRANSABL[ C.H. li II I 1 j I I I I � I % xl� I I i I _ I N ELECTRICAL PLAN � 1/4"=1'-0" l COLUMN LEGEND FCMU CDLUMN (wSEE WALL SECTION) V J U_ -C b 01 iV O V) 0 0 LU LIJ u CN �nn U OF Fj,Q 5 / LANCE A. V( 7'_'k AR96414 Coar"siB".a nY:_'/�/yJ� 4884�4C,' SYMBOLS: WALL. SECTION ELEVATION L BUILDING SECTION ROSE BIB 16'-0° w 01.x40111LCm WALL WlrRSTON6VENEER& I I I CI I ppp�666Imol I CAB. IO" S4^ FRIDGE ?`-8° CAB. I. ��,,jSW I SRlK I I pp11I BECYC. o i �j R ,I r- II II I PROPOSED POOL CABANA I I I I II I � ❑ II I II I I I I I I I � I I P QQ I I I I I � I I I• TV0VEREXCERIORGAS EATE.B LINEAR GAS MEIILACE 1'•PO RE SEI.ECTEB/APPBOVBD BY I I OWCIEIp I• 42'x84" TABLE II II II II II II LI II /ALL W/2"R SfONE VENhERY AP -- o N � FLOOR PLAN EVISIO file Copy Jjo f61jel T FLOOR PLAN, REVIEWED FOR 7' ELECTRICAL )DE COMPLIANC PLAN & r. LUCIE CO .� ELEVATIONS SCANNED Q PROJECT NO., HUNTER 1 �+�, BY z DRAWN BY, LV si1wipromtv 0 DATE, 2.1.19 REVISIONS, 0 1/17/20 FIELD CHANGE U SHEET NO. A2 A% 1/4"=1'-0" ;Ign Envelope ID:451BE5FD-5482-404D-B442.6552725E7DC8 COPPER "EGG" 30"Wx20"1x48"D CAP W/ COPPER SCREEN (DIAMOND PATTERN) EACH END (CHIMNEY KING #30B OR APPROVED EQ. "VERIFY CHIMNEY/CHIMNEY CAP SIZE/ STYLE/FBYISH W/ OWNER) VENT -FREE GAS FIREPLACE 1 BELOW. SEALED CHIMNEY CAP W/ NO PENETRATION. S" POURED SOLID TOP COURSE W/ (1) #5 BAR CONT. 8" CMU CHIMNEY W/ #5 VERT. BAR POURED SOLID @ CORNERS & MIDPOINT EACH SIDE FLASHING PER TILE ROOF MANUF. SPECIFICATONS 12 SIMPSON HU212Z EACH TRUSS J 8"x8" LINTEL @ CHIMNEY OFFSET W/ (1) #5 BAR CONT. TERMINITE CHIMNEY 2FT MIN. ABOVE ROOF RIDGE — — FLASHING PER TILE ROOF MANUF. SPECIFICATONS 3.5:12 CRICKET CHIMNEY DETAIL 3/4"=1'-0" CONC. TH.E ROOF (*MATCH EXISTING) ON PEEL-N-STICK UNDERLAYMENT ON e" CDX PLYWOOD SHEATHING. ENGINEERED WOOD ROOF TRUSSES @ 24" O.C. W/ 51" TOP CHORD SEE TRUSS CONNECTION SCHD. FOR TIE -DOWN CONT. DRIP FLASHING OVER - P.T.1x2, OVER 2x8 SMOOTH CEDAR FASCIA FIELD VERIFY/MATCH EXISTING) ot 10' 0" T,O,B, 6 a III I nl 2'-D"- 1 e" (train.) STUCCO SOFFIT (W/ z CONTINUOUS VENT) OVER e" GALV. RIB LATH ATTACHED W/ GALV. _ RINGSHANK NAILS OR SCREWS W/ A HEAD DIAMETER NOT LESS THAN g" W/ I L'" MIN. PENETRATION INTO HORIZONTAL WOOD FRAMING MEMBERS. (*MATCH HOUSE SOFFIT STUCCO FINISH) BEAM PER SCHEDULE MATCH EXISTING HOUSE STUCCO FINISH 12"x12" CMU W/ 4 #5 VERT. BARS HOOKED TO FOOTING STONE CAP (*TO BE SELECTED BY OWNER) � II II STONE VENEER D STONE SOUTHERN LEDGES ONE IN FOG R I (I COUNTRY LEDGESTONE IN ECHO RIDGE OR APPROVED EQUIV.) *SCREEN o TRACK TO BE RECESSED INTO STONE. `+ 0' 0" T,U,S, THICKENED SLAB EDGE 18" DEEP X 16" WIDE W/ (2) #5 BARS CONT. 3" CLR, I HGA10 EACH TRUSS 1x6 T&G CEILING SIMPSON HU212Z EACH TRUSS Ix6 T&G CEILING REMOVABLE HARDIE-PANEL OR T&G FOR (*VERWY W/ MANUF. SPECS & OWNER) RETRACTABLE SCREEN -AS SELECTED/APPROVED BY OWNER (INSTALL PER MANUF. SPECS) 4" THICK CONC. SLAB WITH 6x6 WWM (OR FIBERMESH) OVER 6 MIL VISQUEEN VAPOR BARRIER, OVER CLEAN, COMPACTED, TERMITE TREATED FILL. 4 TYP. WALL SECTION A3 3/4//_j/_0// ACC& 16'-0' 1 N I ( I ®— --J,--- ---- - ---- -- I I I— 2 =o• � i I I I i� B'-o• I I \,nll ,- I � I , I , -----— — — — — —— I-1— � I I I I I 5 12 5/12 _ — —1 — I I I I I I I j_ T—. 2;-6• I I I L-1 3.5+12 CRICKET j I L-1 i I I I I I I I I I I I I I I I I I I I I I I I I I I — — — — — — — —NZI I — - � I ---- -------------� — ROOF FRAMING PLAN A3 % 1/4"=1'-0° CONCRETE BEAM CHEDULE BEAM ID SIZE REINFORCING STIRRUPS TIE & SPACING TOP OF WALL OR BEAM NOTES BOTTO MIDDLE TOP B-1 8"x16" 8"x8" (1) #5 (1)#5 - - (1) #5 10, 0" VERIFY arrfEL BI �IASI I.1 UP TO 67W OPENING, SHEATHING NAILING SCHEDULE ITEM NAIJ SIZE EDGE FIELD NOTES SPACING SPACING gI" CDX ROOF ZON1',, 1, 2, & 3 (8d ROUND ZONE 1: 4" O.C. ZONE 1: 6" O.C. SHEATHING HEAD (RING SHANK) ZONE 2: 4" O.C. ZONE 2: 4" O.C. ZONE 3: 3" O.C. ZONE 3: 3" O.C. ROOF SHEATHING 8d ROUND HEAD (RING 4" O.C. N/A NAIL 2x FASCIA TO TRUSS TO TOP OF FASCIA SHANKq ENDS W/ (2) 16d NAILS (MIN.) 32" CDX WALL 8d 4" O.C. 6" O.C. SHEATHING *NOTE: SHEATHING NAIL SPACING SHALL NEVER BE LESS THAN 3" O.C. o =W 200F SHEATHING NAILING ZONES " O2 " 3 3 O O 2 0 0 a m O wme O O 0 a 3 0 0 a ,a m Q2 3 I)TH OF END ZONE(*SEE DATA AND DESIGN PRF?SSURES SCI IIEDUI.E SHEET TRUSS CONNECTION SCHEDULE TYPICAL CONNECTION NOTES: ALL MEMBERS ARE ANCHORED TO CONCRETE BEAM WITH SIMPSON HHETA20 UNLESS NOTED OTHERWISE. ALL MEMBERS ARE ANCHORED TO FRAME WALLS WITH (2) SIMPSON HTS20 UNLESS NOTED OTHERWISE ON LAYOUT. TRUSS ID SIMPSON CONNECTOR ID FASTENERS MAX ALLOWED UPLIFT I NOTES TRUSS TO C. BEAM HETA20 PER MANUF. SPECS 1810 GIRDER TO CONC. BEAM HETA20 PER MANUF, SPECS 1810 (EACH) (2) EACH GIRDER END NOTES: -TRUSS DRAWINGS TO BE PROVIDED TO THE ARCHITECT BY THE TRUSS MANUFACTURER FOR REVIEW PRIOR TO RELEASE OF FINAL SIGNED AND SEALED TRUSS DRAWINGS. -TRUSS MANUFACTURER IS RESPONSIBLE FOR FINAL LAYOUT, SPANS, & ALL TRUSS & HEADER ENGINEERING. -TRUSS MANUFACTURER TO INDICATE UPLIFT REACTIONS @ TRUSS/GIRDER ENDS & PROVIDE HANGER CALLOUTS FOR TRUSS TO GIRDER & GIRDER TO GIRDER CONNECTIONS. TRUSS MANUFACTURER TO NOTIFY THE ARCHITECT IF ANY UPLIFT REACTIONS EXCEED THE SPECIFIED VALUES ABOVE. -SIMPSON CONNECTORS SHALL BE ATTACHED PER MANUFACTURER STANDARDS. VERIFY WITH MANUFACTURER PRIOR TO INSTALLATION, -INSTALL MOISTURE BARRIER BETWEEN CONCRETE AND ALL NON PRESSURE -TREATED WOOD FRAMING. -SUBSTITUTION OF ANCHORAGE HARDWARE W/ EQUAL OR GREATER VALUES IS PERMITTED WITH APPROVAL FROM ARCHITECT. ARCHITECT ASSUMES NO RESPONSIBILITY FOR SUBSTITUTIONS WHICH DO NOT MEET THE LOAD REQUIREMENTS, CUT CONTROL JOINTS ( 'xl') AS SOON AS POSSIBLE xSAWR TROWELING, FILL JOINTS W/ LIQUID SEALER. AFTER THICKENED SLAB EDGE 18' DEEP X 36' WIDE W/ (4) #5 BARS CONT. COLUMN SYMBOLS: u 8"x8" GROUT FILT-ED CELL WITH 1 #5 VERTICAL BAR. 12"x12" CMU COLUMN WITH 4 #5 VERTICAL BARS. WALL SYMBOLS: FULL HT. WALL 40"H CMU WALL INTERIOR WALL LOCATION 3 I—.— I ——.—.—._.—.—.—.� � I � I 2-6, I r21" PQmG6li s� I I I THICKENED SLAB EDGE 18' DEEP X ` 16' WIDE W/ (2) ��------ ■ #5 BARS CONT, ■ C""14"LH1INf I I 0' 0' SLAB ELETION (LI AV RS OVERVALA TO BE LEVEL W/ EX.) 4' THICK CONC SLAB WITH 6x6 WWM OVER 6 MIL VISQUEEN VAPOR BARRIER, ,--e• OVER CLEAN, COMPACTED, TERMITE TREATED FILL. I <x,Nm"cmarr I f p I THICKENED SLAB EDGE 18' DEEP X 16' WIDE W/ (2) I #5 BARS CONT. I L - ------ - - - - 3 FOUNDATION PLAN N A3 1/4N=1'-0' PLUMBING LEGEND VENT PIPING P STU➢OR VENT (S.V.) - ROOF VENT C.O. CLEAN OUT PLUMBING NOTES1 A. ALL WORK SHALL COMPLY WITH 2O17 FLORIDA PLUMBING CODE, 2017 FLORIDA GAS CODE, AND ANY OTHER APPLICABLE CODES. B. PLUMBING PIPING & VALVES; -COPPER TYPE 'K' PIPING AND FITTING BELOW SLAB. -COPPER TYPE 'L' PIPING AND FITTINGS ABOVE SLAB. -LEAD FREE SOLDERED JOINTS -SCHEDULE 40 PVC SANITARY SEWER & VENTS. C. VENT TO REAR OF STRUCTURE D. CONTRACTOR TO VERIFY ALL PIPE SIZES/SPECS PER EQUIPMENT AND APPLICABLE CODE, E. CONNECTION TO EQUIPMENT SHALL BE VERIFIED WITH MANUF.'S CERTIFIED DRAWINGS. F. BEFORE FABRICATION, VERIFY AND COORDINATE ALL DIMENSIONS IN FIELD. G. ALL EQUIPMENT SHALL BE SUPPORTED AS REQUIRED TO PROVIDE A VIBRATION FREE, RIGID INSTALLATION, H. PROVIDE WATER HAMMER ARRESTORS AT EACH BRANCH LINE, I. SEE FLOOR PLAN FOR HOSE BIB LOCATIONS 2" SINK TO SEPTIC W�DISP. & DISH. 2" 2„ S.V. LIFT STATION (LIBERTY PUMPS 380 SERIES OR APPR. EQ.) POOL CABANA 5 PLUMBING RISER A3 N T,S, File Copy REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC V C 0 z U C) NO O\ Dri CD ILJU ~ O� Z > N (W O BUJ<�()< QImo,/ 00C� Z< . • 1 1 , W O� l O CD U LJL ® _O Z 0 Q Z > z O uJ - u� O Z O U Q S� OF FLO�'I J LANCE A. VOG4 O ' 0', AR96414 ' U ,IC `PrgRED 'Ag , ^ Dmu�5.ig�nj Ly- 11O) E499dO48092B30C3... U LL) z O Z Q O Z Z U T_ a �-- Q C) Q tz uJ � W ul uJ FOUNDATION/ U) r ROOF FRAMING o PLAN & DETAILS 0 U iL 0 PROJECT NOd HUNTERI DRAWN BY, LV Z DATE, 2.1.19 U REVISIONS, Q 11/20/19 PER B.D. U Q 1/17/20 FIELD CFL1NGE � SHEET NO, Z Li A3