HomeMy WebLinkAboutPLANSSHEET CATALOG I TONY PROFETA - 8.140kW DC, 8.200kW AC I VICINITY MAP
INDEX NO.
DESCRIPTION
SITE PLAN LAYOUT
T-1 COVER PAGE
PNO RMICS Slvd
M-1 MOUNTING DETAIL
M-2 STRUCTURAL DETAIL 75 ii�� TT �8206Sarde
1�01 Clara Boulward
E-1 SINGLE LINE DIAGRAM l�
L Clara Bird 9arda CSara Blvd Sarvo cia•
E-2 LOAD CALCULATIONS PROPERTY LINE
PL-1 WARNING PLACARDS`
SS SPEC SHEET(S)
GENERAL SYSTEM INFORMATION:
SYSTEM SIZE:
814OW DC, 820OW AC
MODULES:
(22)SONALI SOLAR SS M 3370
INVERTER:
(1)FRONIUS PRIMO 8.2-1
APPLICABLE CODES
•ELECTRIC CODE: NEC 2014
• FIRE CODE: FFPC 2017
• BUILDING CODE: FBC 2017
• RESIDENTIAL CODE: FRC 2017
GENERAL NOTES
1.MODULES ARE LISTED UNDER UL 1703 AND
CONFORM TO THE STANDARDS.
2.INVERTERS ARE LISTED UNDER UL 1741 AND
CONFORM TO THE STANDARDS.
3.DRAWINGS ARE DIAGRAMMATIC, INDICATING
GENERAL ARRANGEMENT OF THE PV SYSTEM AND
THE ACTUAL SITE CONDITION MIGHT VARY.
4.WORKING CLEARANCES AROUND THE NEW PV
ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN
ACCORDANCE WITH NEC 110.26.
5.ALL GROUND WIRING CONNECTED TO THE MAIN
SERVICE GROUNDING IN MAIN SERVICE PANEL/
SERVICE EQUIPMENT.
6.ALL CONDUCTORS SHALL BE 600V, 750C
STANDARD COPPER UNLESS OTHERWISE NOTED.
7.WHEN REQUIRED, A LADDER SHALL BE IN PLACE
FOR INSPECTION IN COMPLIANCE WITH OSHA
REGULATIONS.
&THE SYSTEM WILL NOT BE INTERCONNECTED BY
THE CONTRACTOR UNTIL APPROVAL FROM THE
LOCAL JURISDICTION AND/OR THE UTILITY.
9.ROOF ACCESS POINT SHALL BE LOCATED IN
AREAS THAT DO NOT REQUIRE THE PLACEMENT
OF GROUND LADDERS OVER OPENINGS SUCH AS
WINDOWS OR DOORS, AND LOCATED AT STRONG
POINTS OF BUILDING CONSTRUCTION WHERE THE
ACCESS POINT DOES NOT CONFLICT WITH
OVERHEAD OBSTRUCTIONS SUCH AS TREES,
WIRES OR SIGNS.
10.PV ARRAY COMBINER/JUNCTION BOX
PROVIDES TRANSITION FROM ARRAY WIRING TO
CONDUIT WIRING
3' FIRE SETBACK -
PHOTOVOLTAIC ARRAY ON THE ROOF
CONDUIT RUN
(N) PV INVERTER (INTERIOR)
(N) AC DISCONNECT (INTERIOR)
(E) ELE.CTRICAL METER (INTERIOR)
SCALE:1"=20'-0"
SANTA CLARA BLVD
MIN. SETBACK REQ.
VRONT
SIDES_ _
r'NR S1r1FS
awl
BT,LUCIE COUNTY
PLAN REVIEW
SLDG:
DATE:
ELE
DATE
PLUMS:
DATE:
MECH:_
DATE: _
9MAM
CUSTOMER INFORMATION
NAME:TONY PROFETA
ADDRESS:8206 SANTA CLARA
BOULEVARD, FORT PIERCE, FL 34951
27033'08.7"N 80024'28.6"W
APN:130160800540006
AHJ:FL-SAINT LUCIE COUNTY
UTILITY: FPL
PRN NUMBER:REN-004583
COVER PAGE
DESIGNER/CHECKED BY:
S N/AJ
0111wv � �D
H
SCALE:AS NOTED REV:A
DATE:8/29/19 I T-1
INSTALLATION NOTES
1.STRUCTURAL ROOF MEMBER LOCATIONS ARE
ESTIMATED AND SHOULD BE LOCATED AND
VERIFIED BY THE CONTRACTOR WHEN LAG BOLT
PENETRATION OR MECHANICAL ATTACHMENT TO
THE STRUCTURE IS REQUIRED.
2.ROOFTOP PENETRATIONS FOR SOLAR RACKING
WILL BE COMPLETED AND SEALED WITH APPROVED
SEALANT PER CODE BY A LICENSED CONTRACTOR.
3.LAGS MUST HAVE A MINIMUM 2.5" THREAD
EMBEDMENT INTO THE STRUCTURAL MEMBER.
4.ALL PV RACKING ATTACHMENTS SHALL BE
STAGGERED BY ROW BETWEEN THE ROOF FRAMING
MEMBERS AS NECESSARY.
5.ROOF MOUNTED STANDARD RAIL REQUIRES ONE
THERMAL EXPANSION GAP FOR EVERY RUN OF RAIL
GREATER THAN 40.
6.ALL CONDUCTORS AND CONDUITS ON THE ROOF
SHALL BE MINIMUM 2.5" ABOVE THE ROOF
SURFACE (INCLUDING CABLES UNDERNEATH
MODULES AND RACKING).
7.THE PV INSTALLATION SHALL NOT OBSTRUCT ANY
PLUMBING, MECHANICAL OR BUILDING ROOF
VENTS.
ROOF ACCESS PATHWAYS AND SETBACKS:
IFC 605.11.1.2.2 HIP ROOF LAYOUTS
PANELS AND MODULES INSTALLED ON GROUP R-3
BUILDINGS WITH HIP ROOF LAYOUTS SHALL BE
LOCATED IN A MANNER THAT PROVIDES TWO,
3-FOOT WIDE ACCESS PATHWAYS FROM THE EAVE
TO THE RIDGE ON EACH ROOF SLOPE WHERE
PANELS AND MODULES ARE LOCATED. THE ACCESS
PATHWAY SHALL BE AT A LOCATION ON THE
BUILDING CAPABLE OF SUPPORTING THE FIRE
FIGHTERS ACCESSING THE ROOF.
IFC 605.11.1.2.3 SINGLE -RIDGED ROOFS
PANELS AND MODULES INSTALLED ON GROUP R-3
BUILDINGS WITH A SINGLE RIDGE SHALL BE
LOCATED IN A MANNER THAT PROVIDES TWO,
3-FOOT WIDE ACCESS PATHWAYS FROM THE EAVE
TO THE RIDGE ON EACH ROOF SLOPE WHERE
PANELS AND MODULES ARE LOCATED.
IFC 605.11.1.2.4 ROOFS WITH HIPS AND
VALLEYS
PANELS AND MODULES INSTALLED ON GROUP R
BUILDINGS WITH ROOF HIPS AND VALLEYS SHALL
NOT BE LOCATED CLOSER THAN 18 INCHES TO A
HIP OR A VALLEY WHERE PANELS/MODULES ARE TO
BE PLACED ON BOTH SIDES OF A HIP OR VALLEY.
WHERE PANELS ARE TO BE LOCATED ON ONLY ONE
SIDE OF A HIP OR VALLEY THAT IS OF EQUAL
LENGTH, THE PANELS SHALL BE PERMITTED TO BE
PLACED DIRECTLY ADJACENT TO THE HIP OR
VALLEY.
EXCEPTION: THESE REQUIREMENT SHALL NOT
APPLY TO ROOFS WITH SLOPES OF TWO UNITS
VERTICAL IN 12 UNITS HORIZONTAL (2:12) OR
LESS.
SITE INFORMATION - WIND SPEED: 157 MPH AND SNOW LOAD: 0 PSF
AERIAL VIEW
SR.
NO
AZIMUTH
PITCH
NO. OF
MODULES
ARRAY AREA
(SQ. FT.)
ROOF TYPE
ATTACHMENT
ROOF
FRAME TYPE
FRAME
FRAME
MAX RAIL
OVER
EXPOSURE
SIZE
SPACING
SPAN
HANG
TV
" +
MP-01
2700
140
11
2,29.7
METAL ROOF
S-5 SOLAR
ATTIC
PRE -FABRICATED TRUSSES
2 X 4
2'-0"
4'-0"
2'-0"
FOOT
MP-02
900
140
11
229.7
METAL ROOF
S-5 SOLAR
ATTIC
PRE -FABRICATED TRUSSES
2 X 4
2'-0"
4'-0"
2'-0"
FOOT
ALUMINA
ARRAY MFI-01
2 X 4 PRE -FABRICATED
TRUSSES@ 2'-0"SPACI:NG
CUSTOMER INFORMATION
NAME:TONY PROFETA
ADDRESS:8206 SANTA CLARA
BOULEVARD, FORT PIERCE, FL 34951
27033'08.7"N 80024'28.6"W
APN: 130160800540006
AHJ:FL-SAINT LUCIE COUNTY
UTILITY: FPL
PRN NUMBER: REN-004583
MOUNTING DETAIL
DESIGNER/CHECKED BY:
SN/AJ
SCALE:AS NOTED I REV:A
SCALE:1/8" = V-0" I DATE:8/29/19 I M-1
DEAD LOAD CALCULATIONS ATTACHMENT DETAIL— S-5! SOLARFOOT MODULES DATA
BOM QUANTITY LBS/UNIT TOTAL WEIGHT SONALI SOLAR SS M 3370
(LBS)
MODULES 22 49.60 1091.20 SOLAR MODULE T1111 MODULE DIMS 77.16"x38.97"x1.57"
MID -CLAMP 38 0.170 6.46 SOLARFOOT RAIL LAG SCREWS 5/16 x3.511. I 11 .2.511 MIN
6 MAX EMBEDMENT
END -CLAMP 12 0.300 3.60 I
RAIL LENGTH 146 0.790 115.34 I
SPLICE BAR 8 0.650 5.20
S-5 SOLAR 40 0.248 9.92
FOOT�'
TOTAL WEIGHT OF THE SYSTEM (LBS) 1231.72 "' I ® S-5 SOLARFOOT
TOTAL ARRAY AREA ON THE ROOF (SQ. FT.) 459.39 ®4
WEIGHT PER SQ. FT.(LBS) 2.68
WEIGHT PER PENETRATION (LBS) 30.79
MID —CLAMP AND END —CLAMP ANATOMY
MODU'
""T^'''-AMP
END" ""'^
"""JDULE
MODULE TO MODULE & MODULE TO RAIL
SS BONDING PIN
F/ I
i
GROUNDING MID -CLAMP
SCALE: NTS
MID CLAMP
ASSEMBLY
MODULE
FRAME
RAIL
CHANNEL NUT
BACK LEFT FRONT RIGHT
M8-1.25 THREADED STUD
FACTORY APPLIED
BUTYL SEALANT
GENERAL NOTES: �-
1. SOLARFOOT
2. M8-1.25 STAINLESS STEEL IHEX FLANGE NUT (13MM SOCKET)
3. METAL TO METAL:1/4-14 SELF DRILLING SCREW 1-1/2" TO 2-1/2"
METAL TO WOOD:1/4-14 TYPE 17 AB MILLED POINT 1-1/2" TO 2-1/2"
4.EXAMPLE ROOF
GROUNDING
GROUNDING DETAILS
i-12 AWG BARE
COPPER WIRE
a,
1.
4.
C /i G11 18 SS BOLT
IT LOCK WASHER
JE TO 16FT-LBS)
3.
GROUNDING LUG
BOUNDING
CHANNEL NUT
RAIL
NOTES:
• ALL HARDWARE IS :INCLUDED FROM MANUFACTURER
• A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY CONTINUOUS
ROW OF MODULES
• GROUNDING LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL
• GROUNDING LUG MAY BF INSTALLED SO GROUND WIRE IS PARALLEL OR
PERPENDICULAR TO RAIL
• ENSURE SPLIT LOCK WASHER IS INSTALLED ON TOP OF COPPER WIRE.
SCALE: NTS
2
TOP
RAIL TO RAIL
SCALE: NTS
g,CALE: NTS
^r1T1 ' '"IG SCREW
RAIL
11V 1 LI\1 Y/"lL �./l L1 L.L
renvu
CUSTOMER INFORMATION
NAME:TONY PROFETA
ADDRESS:8206 SANTA CLARA
BOULEVARD, FORT PIERCE, FL 34951
27033'08.7"N 80024'28.6"W
APN:130160800540006
AHJ:FL-SAINT LUCIE COUNTY
UTILITY: FPL
PRN NUMBER:REN-004583
STRUCTURAL DETAIL
DESIGNER/CHECKED BY:
S N/AJ
SCALE:AS NOTED I REV:A
DATE:8/29/19 I M-2
SINGLE LINE DIAGRAM: DC SYSTEM SIZE - 8140W, AC SYSTEM SIZE - 820OW
INVERTER-1 SPECIFICATIONS
MODULE SPECIFICATION
SYSTEM CHARACTERISTICS
MODEL
FRONIUS PRIMO 8.2-1
MODEL
SONALI SOLAR SS M
3370
DC SYSTEM SIZE
8140 W
MAX OPEN CIRCUIT VOLTAGE
517.43V
POWER RATING
820OW
MODULE POWER. @ STC
370W
OPERATING VOLTAGE
419.65V
MAX OUTPUT CURRENT
34.2A
OPEN CIRCUIT VOLTAGE:Voc
47.00V
MAX SHORT CIRCUIT CURRENT
25.38A
CEC WEIGHTED EFFICIENCY
96.5%
MAX POWER VOLTAGE:Vmp
38.15V
OPERATING CURRENT
19.40A
MAX INPUT CURRENT
18A
SHORT CIRCUIT VOLTAGE:Isc
10.15A
MAX DC VOLTAGE
600V
MAX POWER CURRENT:Imp
9.70A
EXISTING 120/240V 1PH 60HZ
I METER#:FPL
UTILIT
GRID
(E)200A END FED
MAIN PANEL
z oc
Q w�
� Y
Q
Qw
Lnry
Nm
` 50A 2P
PV BREAKER
PV BREAKER AT THE (EELECTRODE
OPPOSITE END OF =
BUSBAR
(N)60A AC
DISCONNECT
SQUARE D DU222RB AC
DISCONNECT NON FUSED
60A, 120/240V, 2P
MAIN BREAKER DERATE:REPLACE EXISTING MAIN
BREAKER WITH NEW 175A MAIN BREAKER
(N)SONALI SOLAR SS M 3370,
370W MODULES
PV MODULES
MODULES WIRED IN (1)
ail SERIES OF 11 MODULES
(N)FRONIUS PRIMO 8.2-1, 820OW itINVERTER
INVERTER-1
AC
DC
DC DISCO
DUAL_ MPPT STRING COMBINER &
LOAD RATED DC DISCONNECT
G
I(N)JUNCTIONI
BOX OR EQUI.
CONDUIT SCHEDULE
TAG ID
CONDUIT SIZE
CONDUCTOR
NEUTRAL
GROUND
1
NONE
(2) 10AWG PV WIRE
NONE
(1) 10 AWG BARE COPPER
2
3/4" EMT OR EQUIV
(4) 10AWG PV WIRE
NONE
(1) 10 AWG BARE COPPER
(2) 18AWG WITHIN TC-ER
3
3/4"EMT OR EQUIV
(4) 10AWG THHN/THWN-2
NONE
(1) 10 AWG THHN/THWN-2
(2) 16AWG THHN/THWN-2
4 1 3/4"EMT OR EQUIV
(2) 6 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2
DC WIRE SIZING CALCULATIONS BASED OF FOLLOWING EQUATIONS»
• REQUIRED CONDUCTOR AMPACITY: 125% PER 690.8(A)(1) X Isc(A) X #OF
PARALLEL STRINGS = MAX CURRENT PER 690.8(A)(1) X 125% PER
690.8(B)(2)(a)=MAX CURRENT PER 690.8(B)(2)(a)
• CORRECTED AMPACITY CALCULATIONS: AMPACITY X TEMPERATURE DERATE
FACTOR X CONDUIT FILL DEBATE = DERATED CONDUCTOR AMPACITY
• DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(B)(2)(2) <
DERATED CONDUCTOR AMPACITY
AC WIRE SIZING CALCULATIONS BASED OF FOLLOWING EQUATIONS >.>
• REQUIRED CONDUCTOR AMPACITY: INVERTER OUTPUT CURRENT X #OF
INVERTERSXMAX CURRENT PER 690.8(A)(3)X125% PER 690.8(B)(2)(A)
• CORRECTED AMPACITY CALCULATIONS: AMPACITY X TEMPERATURE DERATE
FACTOR X CONDUIT FILL DERATE = DERATED CONDUCTOR AMPACITY
• DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(B)(2)(2) <
DERATED CONDUCTOR AMPACITY
0
(N)RAPID
SHUTDOWN BO
2
c-
SUNNY BOY SMA
RAPID SHUTDOWN
ROOFTOP BOX AND
DISCONNECT SWITCH
600V,10' OF ARRAY
ELECTRICAL. NOTES
1.CONDUCTORS EXPOSED TO SUNLIGH
SHALL BE LISTED AS SUNLIGH
RESISTANT PER NEC 310.0(D).
2.CONDUCTORS EXPOSED TO WE
LOCATIONS SHALL BE SUITABLE FOR USE
IN WET LOCATIONS PER NEC 310.8(C).
3.MAXIMUM DC/AC VOLTAGE DROP SHALL
BE NO MORE THAN 2%.
4.ALL CONDUCTORS SHALL BE IN CONDUI
UNLESS OTHERWISE NOTED.
5.BREAKER/FUSE SIZES CONFORMS T
NEC 240.6 CODE SECTION.
6.AC GROUNDING ELECTRODE
CONDUCTOR SIZED PER NEC 250.66.
7.AMBIENT TEMPERATURE CORRECTIO
FACTOR IS BASED ON NEC 690.31(C).
8.AMBIENT TEMPERATURE ADJUSTMENT
FACTOR IS BASED ON NE
310.15(B)(2)(C).
9.MAX. SYSTEM VOLTAGE CORRECTION I
PER NEC 690.7.
10.CONDUCTORS ARE SIZED PER WIR
AMPACITY TABLE NEC 310.16.
renivu
(N)SONALI SOLAR SS M 3370,
1, 370W MODULES
PV MODULES CUSTOMER INFORMATION
MODULES WIRED IN (1)
ail SERIES OF 11 MODULES NAME:TONY PROFETA
NOTE:
MAIN PANEL RATING:200A, MAIN BREAKER RATING:175A
120% RULE: (200AX1.2)-175A=65A =>ALLOWABLE BACKFEED IS 65A
OCPD CALCULATIONS:
INVERTER OVERCURRENT PROTECTION= INVERTER O/P I X CONTINUOUS LOAD(1.25)
=34.2xl.25=42.75A=>PV BREAKER = 50A
ALLOWABLE BACKFEED 65A =>50A PV BREAKER
THE DESIGNED INTERCONNECTION MEETS THE 705.12(D)(2) REQUIREMENTS.
(1) 10 AWG THHN/THWN-2
ELECTRICAL CALCULATIONS
DC WIRE CALCULATIONS:- MATERIAL:COPPER & TEMPERATURE RATING:901C
TAG ID
REQUIRED CONDUCTOR AMPACITY
CORRECTED AMPACITY CALCULATION
DERATED CONDUCTOR AMPACITY CHECK
1
1.25
X
10.15
X
1
=
12.69
X
1.25
=
15.86A
40
Xj
0.58
1 X
1 1
1 =
23.20A
15.86A
I <
I 23.20A
2
1.25
X
10.15
X
1
=
12.69
X
1.25
=
15.86A
40
X
0.71
1 X
1 0.8
1 =
122.72AI
15.86A
I <
22.72A
AC WIRE CALCULATIONS:- MATERIAL:COPPER & TEMPERATURE RATING:900C
TAG ID
REQUIRED CONDUCTOR AMPACITY
CORRECTED AMPACITY CALCULATION
DERATED CONDUCTOR AMPACITY CHECK
4
34.2
X
E1
=
34.20
X
1.25
=
42.75A
75
X
0.87
X
1
=
65.25A
42.75A
<
65.25A
ADDRESS:8206 SANTA CLARA
BOULEVARD, FORT PIERCE, FL 34951
27033'08.7"N 80024'28.6"W
APN: 130160800540006
AHJ:FL-SAINT LUCIE COUNTY
UTILITY: FPL
PRN NUMBER:REN-004583
SINGLE LINE DIAGRAM
DESIGNER/CHECKED BY:
SN/AJ
SCALE:AS NOTED I REV:A
DATE:8/29/19 I E- 1
RESIDENTIAL LOAD CALCULATION
Residential Optional Calculation
by: John SckoGk Version 2011 L
STEP 1 Article 220.82 (B) (1)7(2)
sq. ft • 1206 General Lighting load
2 Small Appliance
1 Laundry circuit
Gen.Lgt, Sm App.& Laun. Load
STEP 2
Article 220.82 (C) 0
A/C Condenser & Fixed
Electric Space Heating
5 ton
•
7,130 VA
AHU 1 Select •
2 ton
•
2,850 VA
AHU 2 Select •
A/C #3
•
VA
AHU 3 Select •
A/C #4
•
VA
AHU 4 Select •
A/C #5
•
VA
AHU 5 1 Select •
STEP 3
Article 220.82
(B) (3)
GAS
•
1
Water Heater
1,400 VA
•
1
Refrigerator
600 VA
•
1
Freezer
1,030 VA
•
1
Dishwasher
690 VA
•
1
Disposal
400 VA
•
1
R / Hood
1,630 VA
•
1
Microwave
❑
4,000 VA
•
Microwave
170 VA
•
Mini Refrig
❑
400 VA
•
Wine Clr
❑
5,000 VA
IF
Insta Hot
1,500 VA
•
Ironing Center
❑
select • Jacuzzi Tub
❑
select • Sprinkler Pump
❑
select • Well Pump
•
Fountain Pump
Fselect
select •
Elevator
Pool Equip. Panel
7200
Condenser
r�]
10800
Gen
STEP 4 Article 220.82 (B) (3)
Electric Clothes Dryers
STEP 5 Article 220.82 (B) (3)
Electric Ranges 5,400 W
or Number of appliances
3,618 VA
3,000 VA
1,500 VA
8,118 VA
9/25/1997
Residential Load Calcs
Tony Profeta
8206 Santa Clara Boulevard
Fort Pierce FL 34951
0
8/21 /2019 9:48
General lighting, Sm. Appl. & Laundry
QTY Total 2
VA 1
VA 1
VA Qty
VA Qty
VA Qty
• Heating Load
• CU Load
VA
9,980 VA
RIEN-004583
8,118 VA
• Electric Space Heat @ 65% <4, 40% >3, vs. A/C @ 100% 95980 VA
0
VA
1,400 VA
600 VA
1,030 VA
690 VA
400 VA
1,630 VA
VA
VA
VA
VA
VA
VA
VA
VA
VA
VA
VA Apply Demand
7,200 VA No Demand
10,800 VA No Demand
9,000 VA
Col C demand
Appliance Demand Load
Cooktop 5,400 W Col B demand
Check Box for Gas Range Cooktop Col B demand
Ovens) 5,400 W Col B demand
Oven(s) Col B demand
Number of appliances 2 Dem. Factor
Cooktop & Oven Demand Load
Dryer Demand Load
Range Demand Load
Service Demand
Demand Load
Neutral Demand
Min.Service Req.
Min. Feeder size
Min. Neutral size
Eq. Girding Cond.
Total Appliance Load 23,750 VA
23,750 VA
%000 VA
10,800 VA
36,647 VA
153 A
141 A
175 A
1/0
1/0
6
Copper
»»»»»»»»»»»»»»»»»»»»»>CCCCCCCCCCCGCCCGCGGGGGG<G<GGGGG<GCGCCGGCGC<CGGCGC
Pool Panel Feeder Calculation
Continuous Motors
Non -continuous
Spa heater 11 kVA
Pool heater 3.5 ton
Pool heater 5 ton
Pool Light select •
Blower select -
other load
other load
❑ Min.Copper Pool Feeder
0
0
0
0
0
0
(see Note)
......
..... _
.... _ .
......
❑ 240v
❑ 240v
❑ 240v
AWG
A
B
N
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
A
A
A
Minimum Panel Rating
A
Phase Amperes
Neut. load
Continuous
Motors
select •
❑
240v
select •
❑
240v
select •
❑
240v
select •
❑
240v
select •
❑
240v
Non-continuot.is
Motors
select •
select •
Max.Unbalanced Neutral Load
select •
select •
select •
❑ 240v
❑ 240v
❑ 240v
❑ 240v
Lj 240v
Motor Neutral Load
renVLI
CUSTOMER INFORMATION
NAME:TONY PROFETA
ADDRESS:8206 SANTA CLARA
BOULEVARD, FORT PIERCE, FL 34951
27033'08.7"N 80024'28.6"W
APN: 130160800540006
AHJ:FL-SAINT LUCIE COUNTY
UTILITY: FPL
PRN NUMBER:REN-004583
LOAD CALCULATION
DESIGNER/CHECKED BY:
S N/AJ
SCALE:AS NOTED I REV:A
DATE:8/29/19 E-2
WARNING PLACARD
I WARNING
ELECTRIC SHOCK HAZARD
THE DC CONDUCTORS OF THIS PHOTOVOLTAIC
SYSTEM ARE UNGROUNDED AND MAY BE
ENERGIZED
LABEL LOCATION
DC DISCONNECT, INVERTER
[PER CODE: NEC 690.35(F)]
[To be used when inverter is ungrounded]
I A WARNING
ELECTRIC SHOCK HAZARD
DO NOT TOUCH TERMINALS
TERMINALS ON BOTH LINE AND LOAD SIDES MAY
BE ENERGIZED IN THE OPEN POSITION
DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR?.
MODULES ARE EXPOSED TO SUNLIGHT
LABEL LOCATION
AC DISCONNECT,POINT OF INTERCONNECTION
[PER CODE: NEC 690.17(E)]
A WARNING
ELECTRIC SHOCK HAZARD
DO NOT TOUCH TERMINALS
TERMINALS ON BOTH LINE AND LOAD SIDES
MAY BE ENERGIZED IN THE OPEN POSITION
LABEL LOCATION
AC DISCONNECT, POINT OF INTERCONNECTION
[PER CODE: NEC 690.17(E)]
LABEL LOCATION
INVERTER, JUNCTION BOXES(ROOF),
AC DISCONNECT
[PER CODE: NEC 690.13.G.3 & NEC 690.13.G.41
LABEL LOCATION
CONDUIT, COMBINER BOX
[PER CODE: NEC690.31(G)(3)(4) & NEC
690.13(G)(4)]
INVERTER
LABEL LOCATION
AC DISCONNECT , IPOINT OF INTERCONNECTION
[PER CODE: NEC 690.54]
LABEL LOCATION
POINIT OF INTERCONNECTION
(PER CODE: NEC 705.12(D)(7)
[ Not Required if Panel board is rated not less than sum of ampere
ratings of all overcurrent devices supplying it]
CAUTION: SOLAR CIRCUIT
LABEL LOCATION
MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT,
RACEWAYS, ENCLOSURES AND CABLE ASSEM13LES AT LEAST EVERY
10 FT, AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALL
COMBINER/JUNCTION BOXES.
(PER CODE: IFC605.11.1.4)
LABEL LOCATION
DISCONNECT, POINT OF INTERCONNECTION
[PER CODE: NEC690.13(B)]
WARNING
DUAL POVVER SOURCE SECOND
SOURCE IS PHOTOVOLTAIC
SYSTEM
LABEL LOCATION
POINT OF INTERCONNECTION
[PER CODE: NEC705.12(D)(4)]
CAUTION: SOLAR ELECTRIC
SYSTEM CONNECTED
LABEL LOCATION
WEATHER RESISTANT MATERIAL, DURABLE ADHESDIVE,
UL969 AS STANDARD TO WEATHER RATING (UL LISTING
OF MARKINGS NOT REQUIRED), MIN %$" LETTER HEIGHT
ARIAL OR SIMILAR FONT NON-BOLD,PLACED WITHIN
THE: MAIN SERVICE DISCONNECT,PLACED ON THE
OUTSIDE OF THE COVER WHEN DISCONNECT IS
OPERATED WITH THE SERVICE PANEL CLOSED.
(PWER CODE: NEC690.15 ,690.13(B))
LABEL LOCATION
AC DISCONNECT , DC DISCONNECT, POINT OF
INTERCONNECTION
(PER CODE: NEC690.56(C))
WARNING: /!
POWER
TO
THIS BUILDING
IS ALSO
SUPPLIED
FROM THE
FOLLOWING
SOURCES WITH DISCONNECTS LOCATED
AS SHOWN
SOLAi
PHOTOVOLTAII
ARRAYS ON ROO
(N) PV INVERTER (INTERIOR
(N) AC DISCONNECT (INTERIOR)
(E) ELECTRICAL METER (INTERIOF
ALL PLACARDS SHALL BE OF WEATHER PROOF CONSTRUCTION, BACKGROUND ON ALL PLACARDS SHALL BE
RED WITH WHITE LETTERING U.O.N.
PLACARD SHALL BE MOUNTED DIRECTLY ON THE EXISTING UTILITY ELECTRICAL SERVICE.
FASTENERS APPROVED BY THE LOCAL JURISDICTION
renlv,u
CUSTOMER INFORMATION
NAME:TONY PROFETA
ADDRESS:8206 SANTA CLARA
BOULEVARD, FORT PIERCE, FL 34951
27033'08.7"N 80024'28.6"W
APN:130160800540006
AHJ:FL-SAINT LUCIE COUNTY
UTILITY: FPL
PRN NUMBER:REN-004583
WARNING PLACARDS
DESIGNER/CHECKED BY:
SN/AJ
SCALE:AS NOTED
REV:A
LABEL LOCATION
DC DISCONNECT[PER CODE: NEC690.14(C)(2)]
DATE:8/29/19
PL-1
SPEC SHEET
US Office:
Sonali Energees USA LLC.,
409 Grand Avenue, Suite 3,
Englewood, NJ 07631
Tel: 201-568-1424
Toll Free: 1.888.58.SOLAR
info@sonalisolar.com
"ENERGY INSPIRED BY NATURE"
SS M 350 - 370 Series
Quality Product
All Manufactured Modules are tested 100% by EL (Electroluminescence)
during the Production Process and Free from Micro Cracks.
Our high-performance modules are highly efficient, reliable, and provide
optimal output. The company manufactures solar modules in compliance with
global standard including MNRE, IEC 61215, 61730-1, 61730-2, 61701,
UL 1703 ISO 9001:2008 and ISO 14001:2008 and 18001:2007.
High Efficiency
High Module efficiency is obtaining top performance even in diffused light
conditions. We are leaders in providing out customers with maximum sunlight
conversion.
Application Possibilities
Residential and Commercial Rooftops, Car Ports, Solar Farming, Balconies,
Awnings, Street Lights Fences, Canopies, etc.
Our Team
We have a team of qualified experts and engineers making sure that modules
produce maximum powe. We pride ourselves in caring for each individual
customer needs with detailed attentions. Our end goal is to give a highly efficient
product with exceptional customer service.
Guarantee
Our product is durable and has a 25 year performance warranty. Integrated
manufacturing of cells and modules in one production line guaranteees optimum
performance.
RFID
RFID is an Radio Frequency Identification Technology - enables every individual
modules to be uniquely identified. We can provide RFID tag as per customer's
request.
SS M 350 - 370 Series
Electrical Specifications
Models
WSW-350
WSW-355
WSW-360
WSW-365
WSW-370
Nominal Maximum Power (Pmax)
350 W
355 W
360 W
365 W
370 W
Optimum Operating Voltage (Vmp)
37.50 V
37.65 V
37.90 V
38.05 V
38.15 V
Optimum Operating Current (Imp)
9,35 A
9.43 A
9.50 A
9.60 A
9.70 A
Open Circuit Voltage (Voc)
46.40 V
46.60 V
46.80 V
46.90 V
47.00 V
Short Circuit Current (Isc)
9.80 A
9.85 A
9.90 A
10.00 A
10.15 A
" Maximum System Voltage: 1000v IEC/UL
• Measurement Power Tolerance on Power 00/ +%
• Under Standard Test Conditions (STC) of irradiance of 1000W/m2, spectrum AM 1.5 and cell temperature of 25 C
• Normal Operating cell temperature (NOCT) of irradiance of 800W/m2, spectrum AM 1.5 and ambient temperature of 20°C, ± 2°C
Mechanical Specification
Module Specifications
(1960 X 990 X 40 mm) / (77.16 X 38.97 X 1.57 inch)
Weight
22.5 kgs / 49.60 Ibs
Junction
Weatherproof PPO / IP67 rated enclosure with bypass diodes
Cable & Connectors
Solar Cable 1200mm length with 4.Omm2cross section, MC4 compatible or IP67 rated
Cell Arrangement
72 (6 x 12)
Front Cover
Tempered & Low Iron Glass, 3.2 mm
Encapsulate
EVA
Back Cover
Composite Sheet
Frame
Anodized Aluminum Alloy
TemDerature coefficient
Product Guarantees
Coefficient of Current
0.0118
Product Warranty
12 Years
Coefficient of Voltage
-0.2627
Performance Warranty
First 10 Years up to 90%, next 15 years up to 80%
Coefficient of Power
-0.3677
Approvals & Certificates
IEC 61215, 61730-1, 61730-2 & 61701 UL 1703
MCS, MNRE
Tested Operating Conditions
Temperature Cycling Range
.40 to 85
Humidity Freeze, Damp Heat
85% RH
Europe Office: Manufacturing Facility:
Sonali Solar Europe Limited Plot No. 180-199
Moore Stephens (South) Surat Special Economic Zone
City Gates, 2-4 South Gate, Sachin-Dist. Surat 394230 E
Chichester, W. Sussex, Gujarat, India 0
PO 19 8 DJ Tel: + 91 0261 2399910/2398007
saleseurope@sonalisolar.com sales@sonalisolar.com
' SETA
Vv!Ni ISO 14MISM
Rev 02.W-09.14.2018
Dimensions
Front View Side View
• JUNCTION --
BOX
4-1,2x8 )
MOUNTING
SLOTS
0
0
O
N
2-04
GROUNDING
SLOTS
Negative(-)
(!)positive
4-DRAINAGE SLOTS
942mm
990mm
REAR VIEW
IV Curve
I-V Curve Variation with Irradiance I-V Curve Variation with Temperature
Cell temp. 26 C
10
1000 W/m :
10
`7
t3
8
800W/m 2
:
6
600 W/m z
<
6
a�i
4
z
4
Incident Irrad = 1000 W/m2
400 W/m
U
Cell temp. = 10°C
U
2
200 W/m 2
2
Cell temp. = 250C
Cell temp. = 40 C
Cell temp. = 55 `C
Cell temp. = 70 `C
0
0
0
10 20 30 40 50
0
10 20 30
Voltage (V)
Voltage (V)
a
2
40mm a
SIDE VIEW
REBFI MAMCE WARRANTY
rcsr,rdvuW t !11 y.V�T%.1, falY�ad
40 50
Rev 02.W-09.14.2018
renvu
CUSTOMER INFORMATION
NAME:TONY PROFETA
ADDRESS:8206 SANTA CLARA
BOULEVARD, FORT PIERCE, FL 34951
27033'08.7"N 80024'28.6"W
APN:130160800540006
AHJ:FL-SAINT LUCIE COUNTY
UTILITY: FP
PRN NUMBER:REN-004583
MODULE SPEC SHEET
DESIGNER/CHECKED BY:
S N/AJ
SCALE:AS NOTED I REV:A
DATE:8/29/19 1 SS-1
SPEC SHEET
lergy / Perfect Charging AP%f,
/ Open data
communication
/ Smart Grid
Ready
/ Arc Fault Circuit
Interruption
s
SHIFTING THE LIMITS
as Primo is the ideal compact single-phase inverter for residential and small-scale commercial
ategories from 3.8 to 8.2 kW. In accordance with ESA rules for residential applications, the
efficiently at a maximum input voltage of 600 V. And for increased efficiency and additional
1 applications, the Fronius Primo can operate at the maximum input voltage of 1,000 V. Industry -
standard with the Fronius Primo, including: dual maximum power point tracking, arc fault
less monitoring and SunSpec Modbus interfaces for seamless monitoring and datalogging via
platform, Fronius Solar.web.
FRONIUS PRIMO 3.8 - 8.2 FRONIUS PRIMO 10.0-15.0
M•
16.9x24.7x8.1in. /42.9x62.7x20.6cm 20.1 x 28.5 x 8.9 in. / 51.1 x72.4x20.6cm
47.4 lb. / 21.5 kg 82.5 lbs. / 37.4 kg
NEMA 4X
< I W
Trans formerless
Controlled forced ventilation, variable speed fan
Indoor and outdoor installation
-40 to 131 F / -40 to 55 C -40 to 140 F / -40 to 60 C
0-100`90
2x DC+1, 2x DC+2 and 4x DC- screw terminals for solid: copper 4x DC+1, 2x DC+2 and 6x DC- screw terminals for copper (solid /
and aluminium stranded / fine stranded: copper and aluminium stranded / fine stranded) or aluminum (solid / stranded)
Screw terminals 12 - 6 AWG
Optional (ANSI C12.1 accuracy)
UL 1741-2015, UL1998 (for functions: AFCI, RCMU and UL 1741-2015, UL1998 (for functions: AFCI, RCMU and
isolation monitoring), IEEE 1547-2003, IEEE 1547.1-2003, isolation monitoring), IEEE 1547-2003, IEEE 1547.1-2003,
As ANSI/IEEE C62.41, FCC Part 15 A & B, NEC 2014 Article 690, ANSI/IEEE C62.41, FCC Part 15 A & B, NEC Article 690-2014,
C22. 2 No. 107.1-01 (September 2001) , UL1699B Issue 2 -2013, C22. 2 No. 107.1-01 (September 2001) , UL1699B Issue 2 -2013,
CSA TIL M-07 Issue 1 -2013 CSA TIL M-07 Issue 1 -2013
STANDARD WITH ALL PRIMO MODELS
Ycs
4onitor y„.
Ycs
AVAILAB
Standard
Standard
ebserver Optional
Optional
irk of the Wi-Fi Alliance.
AVAILABLE WITH ALL FRONIUS PRIMO MODELS
Datalogging and inverter update via 11SB
Fronius Solar Net'iin�terface protocol
Wireless standard 802.11 b/g/n / Fronius Solar.web, SunSpec Modbus TCP, )SON / SuuSpec Modbus RTII
External relay controls
INPUT DATA
Max. permitted PV power (kWp)
Max. usable input current (MPPT 1/MPPT 2)
Total max. DC current
Max. admissible input current (MPPT I/MPPT 2)
Operating voltage range
Max. input voltage
Nominal input voltage
Admissible conductor size DC
MPP voltage range
Number of MPPT
I .1111II1Jw-1
Max. output Power
240 V
208 V
Max. output fault current / Duration
240 V
Max. continuous output current
240 V
208 V
Recommended OCPD/AC breaker size
240 V
208 V
Max. efficiency (Lite version)
CEC efficiency (Lite version) 240 V
Admissible conductor size AC
Grid connection
Frequency
Total harmonic distortion
Power factor (cos (par
It1:111spill /J
Max. i)(11I IIed PV power (kWp)
Max. usable input current (MPPT I/MPPT 2)
Total max. DC current
Max. admissible input current (MPPT 1/MPPT 2)
Operating voltage range
Max. input voltage
Nominal input voltage
Admissible conductor size DC
MPP Voltage Range
Number of MPPT
OUTPUT DATA
Max. output power
Max. output fault current / Duration
Max. continuous output current
Recommended OCPD/AC breaker size
Max. efficiency (Lite version)
CEC efficiency (Live version)
Admissible conductor size AC
Grid connection
Frequency
Total harmonic distortion
Power factor (cos (Pats)
PRIMO 3.8-1
5.7 kV\/
18A/ISA
410 V
200 - 800 V
PRIMO 3.8-1
3,800 W
3,800 W
584 A Peak / 154 ins
15.8 A
18.3 A
20 A
25 A
95.5
PRIMO 10.0-1
15.00 kW
PRIMO 5.0-1
PRIMO 6.0-1
PRIMO 7.6-1
7.5kW
9.0kW
11.4kW
18A/18A
18A/18A
18A/18A
36 A
27 A
80 V - 1,000 V
1,000 V
420 V
420 V
420 V
AWG 14 - AWG 6
240 - 800 V
240 - 800 V
250 - 800 V
PRIMO 8.2-1
12.3 kW
18A/18A
420 V
270 - 800 V
5,000 W
6,000 W
7,600 W
8,200 W
5,000 W
6,000 W
7,600 W
7,900 W
584 A Peak / 154 ins
584 A Peak / 154 ins
584 A Peak / 154 ins
584 A Peak / 154 ins
20.8A
25.0A
31.7A
34.2A
24.0A
28.8A
36.5A
38.0A
30A
35A
40A
45A
30 A
40 A
50 A
50 A
97.9 %
96.5 %
96.5 %
97.0 %
97.0
AWG 14 - AWG 6
208 / 240 V
60 Hz
< 5.0 %
0.85 - 1 ind./cap
PRIMO 11.4-1 PRIMO 12.5-1 PRIMO 15.0-1
17-10 kW 18.7.5 kW 11.50 k%V
33.0 A / 18.0 A
51A
49.5A/27.0A
80 V - 1,000 V
1,000 V
655 V 660 V 665 V 680 V
AWG 14 - AWG 6 copper direct, AWG 6 aluminum direct, AWG 4 - AWG 2 copper or aluminum with optional input combiner
220 - 800 V 240 - 800 V 260 - 800 V 320 - 800 V
2
PRIMO 10.0-1
PRIMO 11.4-1
PRIMO 12.5-1
PRIMO 15.0-1
240 V
9,995 W
11,400 W
1? 00 W
15,000 W
208 V
9,995 W
11,400 W
12,500 W
13,750 W
240 V
916 A Peak / 6-46 ms
916 A Peak / 6.46 nrs
916 A Peak / 6.40 ins
916 A Peak / 6.46 ins
240 V
41.6 A
47.5 A
52.1 A
62.5 A
208 V
48-1 A
54.8 A
60.1 A
66.1 A
240 V
60 A
60 A
70 A
80 A
208 V
60 A
70 A
80 A
90 A
97.9 %
240 V
965 `Z,
96.5 0/o
96.5 %
97.0 %
AWG 10
- AWG 2 copper (solid / stranded /
fine stranded)
, AWG 6 - AWG 2 copper (solid / stranded)
208 / 240 V
60 Hz
< 2.5 %
0-1 ind./cap.
Fronius Canada Ltd. / 2875 Argentia Road, Units 3 - 6 / Mississauga, ON L5N 8G6 / www.fronius.ca / 905-288-2100
SPEC SHEET
�ioiart-ootTM Mounfinafor Exnosed (Fastener moots n
The SolarFoot is a simple, cost-effective pedestal for L-Foot (not included)
attachment of rail -mounted solar PV. The unique design is compatible with
all rail producer L-Foot components. The new SolarFoot assembly ensures a
durable weathertight solution for the life of the roof. Special factory applied
butyl co -polymeric sealant contained in a reservoir is The Right Way, allowing a
water -tested seal. Stainless integrated stud and Ilex flange lock -nut secure the
L-Foot into position. A low center of gravity reduces the moment arm commonly
associated with L-Foot attachments. Direct attachment of the SolarFoot to the
structural member or deck provides unparalleled holding strength.
Pmm]
�9x� 0.315in—7
.00n
wn
-®-
4 0
Patmrad
3.1]in
3.67m
*Fasteners sold separately. Fastener type varies with substrate. Contact 5-5! on how to purchase fasteners
and obtain our test results. L-Foot also sold separately.
Fastener Selection
Metal to Metal:
1/4-14 Self Drilling Screw
1-1 /2" to 2-1 /2"
Slyt � 9T+ram
Metal to Wood:
1/4-14Type 17 AB Milled Point
1-1/2"to 2-1/2"
To source fasteners for your projects, contact S-5!
When other brands claim to be "just as good as S-5! ; tell them to PROVE IT.
S-5!1 Warning! Please use this product responsibly!
The independent lab test data found at www.S-5.com can be used for load -critical designs and applications.
Products are protected by multiple U.S. and foreign patents. For published data regarding holding strength,
fastener torque, patents, and trademarks, visit the S-5! website at www.S-5.com. Copyright 2017, Metal Roof
Innovations, Ltd. S-5! products are patent protected.
Copyright 2017, Metal Roof Innovations, Ltd. Version 102017
SolarFoot Advantages:
Exposed fastener mounting
platform for solar arrays attached
via L-Foot and Rails
Weatherproof attachment to
exposed fastener roofing
Butyl sealant reservoir provides
long-term waterproof seal
M8-1.25x17mm stud with M8 hex
flange nut for attachment of all
popular L-Foot/rail combinations
Tool: 13 mm Hex Socket or 112"
Hex Socket
Tool Required: Electric screw gun
with hex drive socket for self -
tapping screws.
Low Center of Gravity reduces
moment arm commonly
associated with L-Foot/Rail solar
mounting scenarios
Attaches directly to structure or
deck for optimal holding strength
S-5! Recommended substrate -
specific (e.g. steel purlin, wood
2x4, OSB, etc.) fasteners provide
excellent waterproofing and pull-
out strength
Fastener through -hole
locations comply with NDS
(National Design Specification)for
Wood Construction
Distributed by:
renvu
CUSTOMER INFORMATION
NAME:TONY PROFETA
ADDRESS:8206 SANTA CLARA
BOULEVARD, FORT PIERCE, FL 34951
27033'08.7"N 80024'28.6"W
APN: 130160800540006
AHJ:FL-SAINT LUCIE COUNTY
UTILITY: FPL
PRN NUMBER:REN-004583
MOUNT SPEC: SHEET
DESIGNER/CHECKED BY:
SN/AJ
SCALE:AS NOTED I REV:A
DATE:8/29/19 I SS-3