HomeMy WebLinkAboutPLANS51 '- !l 114 "
20' 6" 22' 0"
52 6 7/6"
160 '-11 "
57= 0112"
16:2„
_ _55'- 9 114 "
4TY WALL, SHEET -ROCK EACH SIDE w/ 5/611FIRECODE TYPE `C' TO
DECK.
7
Roof
Framing
Plan
SCALE118 = 1 '- 0"
TRUSS MFGR.
SHALL SUBMIT
LAYOUT DRAWINGS PRIOR
TO FABRICATION
DESIGN LIVE
LOAD 20 PSF
of
SWED
13Y
�Jot Lucie county
.q)
(„) E
0
o LL
J �
E
� o
_ cJ
�c
E
G U
7
Q �
� w
w
w
x
to
e
Y3
(P _
2 Bedroom Model A
RANGE
AC & HEAT
STRIP
HW HEATER
6
BATHROOM G.F.I.
Kld APPLIANCES
SHWASHER
REFRIGERATOR
(GENERAL LIGHTING
GENERAL LIGHTING
DINING ROOM
l Bedroom Model A
RANGE
AC. & HEAT
STRIP
HW HEATER
'LEX RECEPT w/
, TYP. ALL UNITS
BATHROOM G.F.I.
KITCHEN APPLIANCES
DISHWASHER
LREEgnG RATOR _
GENERAL LIGHTING
GENERAL LIGHTING
1.
�PC.
RC.
1"J
j30 GAL.!#WH
PANEL "A„
I � I
I
I
WP
I \ll'�LL�IdI,-p
LDW
�+ RGE. 8
TO UNDER
YYY CAB LTS. YYY
tt
II
II
II
II
l Bedroom Model B
SUB FEED
TO H, P. #2
HOUSE LIGHTS
SPARE
SPARE
SPARE
N
R£F.
Legend
110 v. DUPLEX RECEPTACLE
110 V. DUPLEX RECEPTACLE, TOP 112 SWITCHED
==eWP 110 v. DUPLEX RECEPTACLE, WEATHERPROOF GFI
220 v. RECEPTACLE
TV PRE - WIRED TELEVISION OUTLET
SINGLE POLE SWITCH
3 THREE- WAY SWITCH
CEILING FIXTURE
WALL BRACKET FIXTURE
PC PULL- CHAIN
PHONE JACK
® EXHAUST FAN
FS] SMOKE DETECTOR
DISP. o GARBAGE DISPOSAL
I
HOUSE LIGHTS
HOUSE LIGHTS
HOUSE LIGHTS
SPARE
SPARE.
SPARE
,- -----
THIS PHONE JACK ROUGH —IN AT
48" ABOVE FLOOR
2 Bedroom Model B
DRYER
DRYER
HW HEATER
Typical I Br. Panel
Typical 2 Br. Panel
House Panel
House Panel #2
100 A MLO 1201240V 10 13WISN
100 A MLO 1201240 V 1 0 13WISN
100 A MLO 1201240V I0 /3W/SN
I00 A MLO 1201240V I 0 /3W!BN
12 CIRCUIT FLUSH MOUNT
12 CIRCUIT FLUSH MOUNT
12 CIRCUIT SURFACE MOUNT
12 CIRCUIT SURFACE MOON-
NASHER
WASHER
HOUSE LIGHTS
HOUSE LIGHT;
SPARE
SPARE
Electrical Plans SCAi.E 114"=
2 Bedroom Model A
6
I Bedroom Model A
1 Bedroom Model B
Air Conditioning Plans
2 Bedroom Model B
Equipment Schedule
Apartment Model
2 Br. A
1 Br. A
1 Br. B
2 Br. B
CONDENSING UNIT
let FLOOR
2 TON
1.5 TON
2 TON
1.5 TON_
1.5 TON
2 TON
2 TON
2nd FLOOR
2 TON
AIR HANDLING UNIT
let FLOOR
2 TON
2.5 TON
1.5 TON
1.5 TON
1.5 TON
2 TON
2.5 TON
2nd FLOOR
2 TON
HEAT STRIP
let FLOOR
8 KW.
—__..--
10 KW.
5 KW.
---._.... _ ..
8 KW.
_ 5 KW.
5 KW.
8 KW.
10 KW.
--------
2nd FLOOR
O INDICATES THERMOSTAT AT 60" ABOVE FIN. FLOOR
SCALE: 114"= 1'-0"
b
240 LB. ASPHALT SHINGLE ROOF
SCREEN DI►J ALUM.
G SAND FINISH 1_
�1 STUCCO -
HE=
Front Elevation SCALE :I/B"=1'-0"
Right Side Elevation SCALE: 118"
LEFT SIDE SIMILAR , OPPOSITE HAND.
12
4
Rear Elevation SCALE /B
FINISH GRADE
o1
W
G
w
w
0
i
C1
0
i
Meter Center
600 A. 3P MAIN CIRCUIT BREAKER
w/(16) - 100 A 2P METER SOCKETS
9 15 100 A.2P CIRCUIT BREAKERS.
TYPICAL
APT
PANEL �
5 l 9 J /3
MAIN
SWITCH
�
�J
.` �6 �
CIRCUIT
l
!`
BREAKER
1201240
10 /3 W/SNI
J
// 1 '. H 1
511- 11 1/4 "
20'- B' --
NOTE: LOCATE METER ROOM
AT END OF BUILDING
CLOSEST TO TRANS-
FORMER.
MAILBOXES
26' 0 "
2 Bedroom Model A 2 Bedroom Model B
52'- 6 7/8"
I20V PHOTO 20A, 4 POLE LIGHTING CONTACTOR
CELL PC FOR HOUSE LIGHTING CKTS.
JJ TEST SWITCH
OUSE HOUSE
IPOI NO
NEL PANEL
1
CU'GROUNDING ELECTRODE
>UCTOR TO DRIVFN GROUND
' � =- _
Building Service
2 PARALLEL 3 CONDUITS w/ THE FOLLOWING IN EACH:
(4)-250 MCM AL CONDUCTORS
(I)-250 MCM AL NEUTRAL CONDUCTORS
Y
(2)-#1 THW AL.,(1)-#2 THW AL. e
(1) - #8 THW CU. BOND 1N 1 1/2" PVC COND.
Electrical Riser Diagram
NTS
160'- ll "
57 "-__0 1/2"
I Bedroom Model A
Walk or Balcony
55'- 9 I/4 "
l9'-2" _
l Bedroom Model A
J
'0 (3) A/C CONDENSERS (TYR)
O
26 0 —
2 Bedroom Model B
40 GAL.LO - BOY HWH ON
SHELF ABOVE.
(BOTH FLOORS)
24 8„
2 Bedroom Model A
52 - 6 7/ 8 „
F-001
(2)-A/C CONDENSERS (TYP.)
Building Floor Plan - House Electrical Play! SCALE 1/8 C"
BOTH FLOORS SIMILAR EXCEPT AS NOTED
Legend
BRACKET LIGHT FIXTURE
RECESSED CAN LIGHT IN SOFFIT (CENTER ON BLOCK WALL)
-(PC PULL CHAIN LIGHT
L� EXIT LIGHT (SECOND FLOOR ONLY)
OF FIRE EXTINGUISHER
0
If
I,_ 4„
24'-8
O '
T-I-H PLYWOOD- ___-- -UNFINISHED(TYP
II Screened Porch Storage
I
W O
Bedroom Q y Bedroom
ll 4 1/2" o W 13'0"
J—t_
C - 23
- J
LU
N Q
a MI U
• ;
O n'
O O
t^ 1p Z U
2•-4„ y W FS-
_ y 1 W y O
� . (3) / � C3;' o o
- ill L11'(11
I �r -- t ,C/os.awe 5 v�" . 5'_ 1
4 —
f Both • 3 0 1?✓a k ; In -Clos Bath
CT
j
R J l F18ERGLA55 SH
RE 4 5 SH. p — — --
w 4- a
LivingRoom
(A�, Kitchen
I i M I
_ M
_ti I
ry
20"x 44° MICA COUNTER, J2"HIGH
-_-__ 8 '- 11 I/2.. _--------- i5 - 5-'
Dining
m
.—_�jug1• ,Ir. i. II',i r'. -- I.IjIi 1111iIWlj-�
2 Bedroom Model A
o
e
24"x �24"ACCESS SCUTTLE
2n& FLOOR ONLY, TYP ALL
STORAGE CLOSETS.
M
i
0
19'-2"
-- 6 O
O
Storage
5_4" O
SCREEN ON ALUMINUM FRAMING, TYPICAL
I
Screened Porch
Bedroom
16 '- 6 1/4
q
5 S nH.
�i
)31Wdern 4) Bath U3
y
h O �4
oZvi
to AHU
l / DROP T
y.. HIM 1
UNDER j IDW
44. -
Kitchen
_L_..
Living Room '
N
Ot "1
I
Dining
1 �/l
-O
. „
- 23 [1
•
Room Finish Schedule
area
floor
base
Wo/Is
ceiling remarks
LIVING ROOM
CARPET
WOOD
SHEETROCK
SHEETROCK
DINING AREA
CARPET
WOOD
SHEETROCK
SHEETROCK
HALL
CARPET
WOOD
3HEETROCK
SHEETROCK
ICLNG. HT.
st.
al. FLOOR ONLY
BEDROOM NO.1
CARPET
WOOD
SHEETROCK
SHEETROCK
BEDROOM NO.2
CARPET
WOOD
SHEETROCK
SHEETROCK
CLOSETS
CARPET
WOOD
SHEETROCK
SHEETROCK
SHEETROCK
SHEETROCK
KITCHEN
BATH NO.I
VINYL
WOOD
WOOD
SHEETROCK
VINYL
SHEETROCK
BATH NO
VINYL
WOOD
SHEETROCK
SHEETROCK
SCREENED PORCH
CONCRETE
NONE
SCR./STUCCO
CONC.orUPSOM
NOTE, 5/8" FIRECODE TYPE "C" SHEETROCK,ALL INTERIOR CEILINGS.
1/2" REGULAR SHEETROCK ALL INTERIOR WALLS, SPRAY w/ORANGE PEEL PRIMER.
SMOOTH FINISH KITCHEN& BATH CEILINGS, ACOUSTIC SPRAY ALL OTHER CEILINGS.
/ Bedroom Model A
a
07
-16,-2"
O
Storage I Screened Porch
-- 5--4�� -_ 09
o
Bedroom
2 i41/ 6 13 '- 6 114
\6
3�
W COATED SH S _-- Bath r ' .._..._.
> 4 h
q
- W AS SHOWN114
..._
M AHU_-r
HWH VNVR i t DROP
CLNG.
—4'_9114 3 2
40
Dinin Kitchen
U
i
12"WIDE MICA COUNTER,
42" HIGH.
• -- T ! 73 4
M
01
Living Room
7F
Bn 2,-en
l Bedroom Model B
Door Schedule
mark
size
type
material
finish
frame
remarks
1
3066
FLUSH
METAL
PAINT
WOOD
INSULATED
2
2868
FLUSH
WOOD
PAINT
WOOD
FULL LOUVERED
3
2668
FLUSH
WOOD
PAINT
WOOD
4
2068
FLUSH
WOOD
PAINT
WOOD
5
1666
FLUSH
WOOD
PAINT
WOOD
_
6
4068
91-FOLD
METAL
FACTORY
NONE
FULL LOUVERED
7
6068
8068
SL.GLASS
GL./ALUM.
FACTORY
ALUM.
TEMPERED GLASS
8
SL. GLASS
GL./ALUM.
FACTORY
ALUM.
TEMPERED GLASS
9
3068
FLUSH
SCR/ALUM.
FACTORY
ALUM.
Ist FLOOR ONLY
10
3068
FLASH
METAL
PAINT
METAL
BOT PANEL LOUVER
26,-0„ `
i
I
(9)
Storage_ �I
- 5 4., l2)
Bedroom
13 '- 2 112
M
tb
N
Screened Porch �illj
I ofI
Living Room ••
�I -
I
I
m
5, " 4�-21/2" _ 3,-2•• -I i
Bath' W /k-In•Cl
--_-.__ ` CROP CLNG,
F— Lj
I _
_OW��(
--_I Y AHU ---
7
/ \ HYt1"tl UryiDER
—J 0
' - DROP C.d.Nbl I i
Batt( 4)
C.� Dining I
C 1 `J
"•mil 6 - 1� 2 G s, 13-
25"HIGH OPEIW AG40 �-- 0
-
3% ABOVE FLO _
•
-,� 9 W
MI
.S ELF
--- �. 91-----------
REF
L_DW-
M
o
i--
aI
�,,
•
b'
KitchenOA
Bedroom
�
�
M
0Q
- _-
i>
41�
4"
NOTE: LAYOUT DIMENSIONS ARE FROM FACE
OF BLOCK
WALLS.
2
Bedroom
Model
B
Window Schedule
mark
designation
type
frame
glazing
unit size
masonry openin
A
23
SING, HUNG
ALUM.
CLEAR
37"x 38 3/8
38" x 47"
54"x 47"
B
33
SING. HUNG
ALUM.
CLEAR
53 1/8"x 38 3/8"
C
(2)- 23
SING. HUNG
ALUM.
CLEAR
74"x 38 3/8
75 "x 47" _
D
34
SING. HUNG
ALUM.
CLEAR _
53 I/8 "x 50 5/8 °
54"x 55
E
_-
(2) - 3063
SING. HUNG
ALUM.
CLEAR
6l" x 63."
62"x /O
F
(2) - 24
SING. HUNG
ALUM_-
CLEAR
74"x 50 5/8 " — _
75".x 55 "
G
(2) - 25
SING. HUNG
_.
ALUM.
CLEAR
74"x 63"
75 11 x 70°
NOTE: WINDOWS SHALL BE HARCAR OR EQUAL
FRAMES ARE MILL FINISH
I
3018
APT.
APT.
APT.
103
104
105
203
204
205
l BR: A
I BR.-B
I BR. -A
APT.
I APT.
APT.
APT.
101
102
106
107
201
202
206
207
28R. -A
28R,-B
2 HR.-B
2 BR -A
Typical Building Layout
APT.
NO.
TYPE
KITCHEN
_ MASTER
VANITIES
BATH BATH
NO. 2
I01
&
201
2 BR. -A
NO.
3
HT
RIG_
NO. I
NO.3
102
&
_
202
2 BR. -B
N0.
I
LEFT
____
N0. 7
NO
103
!3
003
/ 8R. -A
N0.
2
RIGHT
_ ND. 8
104
$
204
1 BR. -B
NO.
2
RIGHT
NO. 7
-
-NO.
-7
105
9
205
1 BR. -A
N0.2
LEFT
N0.7
/06
A
206
2 BR. -B
NO.
--,
l
RIGHT
NO. 8
N0.
6
107
&
207
2 R.
N0.
3
LEFT
N0.4-::74
N0.2
Vanity and Kitchen Schedule
TYP. MICA BACK & SIDE SPLASH
0 1
i
I
I
836 1 BIB
No.
Ir
ICDI
B18 1 - 836
No. 2
No. 5
848 - -- ------
I
No. 6
No. 3 No. 7
MICA TOP
I
END PANEL TO MA
WALL CABINET
It1IL:
"
n
24"DW.
3"FILL ER
W
J
J
LL
2114
REF
2"FILLER
l "" FILLL. ER 2 1/2"FILER
I 1835 1 30"RANGE 2135
B'-0• F. ---
- __r -�
13/4_R. _ �r�31/2
Kitchen No. I - Left
36"FL.
2430 SC
C78ACK PANEL
CSHELF 33I8
48" FL.
2730
L O
D.C.
.--- 3635 S
24" DW.
D �
11/2"FILLER
m
3' FILLER
W O
M
2
n
MLn
X
h In
W�
0
M
In
—I" FILLER
`j II
3'- 0 "
7'- 6 " F
7'- 7 3/4" R.
Kitchen No. 2 - Left
I BR. MODEL A
cc
W
4
a
4W,
N
W
2
m
¢
a
a
N k
a
m
M
i
4
-
x
I
\I
I�
xi
�I
I
No_8 No. 9 -- -- - —
20 x 44 MICA BAR �ON
TOP OF KNEE WAL ro
3'- 4 1/2"
8'- 11 1/2"R. �3 112"
Bathroom Vanity Layouts SCALE 1/2 -0"
Kitchen No. 3-Left
2 8R. MODEL A
Kitchen Layouts SCALE 1/2"= I'-O"
rik
NOSING EA TREAD
R4 BAAS#' f-0/L.
1
m i \
`ND 51NL 01 TPLAO
(Bl-a1 soldf E-o.'C
a NI
\�r
J
.Ow EL S or 6 <✓<. 2+� lONO
1 >e' . • w . Jr R S f4!# P 2 Al SIPR
FCfSS SLAB 12l •Y •-
-
S+oir Section - Lower Run
0 10•
-- 6 tR FADS PI 10
6EGONO FtI
.NOSING [A iREAp -1 L
1
__-- -{-- is
•4 BARS o18b/c
09 BARS S-B'LONGI
398`RADIGS, FRONT (8).R4 BAR3e16.0,O 1
EDGE OF ALL TRE40S -
'NANFER
R�—.
:
:I
R8 BAR VENT PEOESTAL Of INFO i
12
r
201
1
Stoir Section- Uppe
SCALE 9.A-•1'. O` r ---
4I�$
1
I I
° p
I la
i 111I
°
I •
1
I � � I OI I ` � I �-
I I d �o-
_-_jj
�
I LLu,
V!"I%F-117I7-�
kit
1 I ,
i
if
1 /
I
I
,I
---1—
,Y
,l
., "of: I
-o�d loll 19 A-t�Lt�)kv 4,T
l C nd CN RFi a'.g' �
I
t
y
#2 Tor VVH,
rJ6CL5 (e S 0/c,
ale
J
1' (2R1 #M I�hfPfs �I'
- . I> P�,wr-h a$CJ % 111' Lvw7 � �
I I
w SHIM rA t ,.Z.
He
If _ ° ° l/rV?,PV f-T eWr-fzOH ZLVI j 6Z&pD
'TG 'fs D6F41H TU 51 G� d��l L�v��j .
i
.` ._
IfT -...r r _.
I II
h{iOf2'T I I - aj -ib � pjv(Lh , C t2 GTs•) . --� � -- - — _--_. __
Il f
t2' pl'
STAIRWAY SECTION
Lao
f2PV�i2bG ��I-►�.{1.Ca t-b'j�,p -
i
IL
4
t-
W
LL
L
w
0
i
TOP OF TIE BEAM
ROOF TRUSSES
325 FIBERGLASS SHINGLE ROOF OVER
5/8"CDX PLYWOOD SHTNG.
2"x 8" SUB - FASCIA
1"x8"R.S. CEDAR FASCIA
1"x2" R.S. CEDAR DRIP
/ 26 GA. GALV DRIP CAP
FIELD
APPLIED LEVEL RETUR\
SOFFIT
ED UPSOM
O
O" CANTILEVER
1-00"
Balcony Overhang and Foscia Detail 2
A-5
SCALE: I"= I'- 0 "
LEVEL RETURNS,._24'0/C :..
J,7
PT. NAILER
UPSOM SOFFIT w/SCR. VENTS
2•-0„ I 6 10„
I
I
I
at 36 " 5/8" STUCCO ----
�kt `
p CANTILEVERED PORCH
? SEE SHEET A-6 FOR\REINF.
a 3/4" STEP
R
E-- 11/2 " SLOPE
f
� I
Q I 6'-0"
a I
I
W
4 I
N I
_w _
3
A-5
22'- 0"
11'.9 L
y
a
a
Q
,.
-'
STAIRS UPLL
P
LL
4
(4) -
I/2" ANC ORB LT
C
12"
SEI
IN SLA
O
4
I
EDGE
OF
SLA ON GRADE
I
c
I
I p
4
P
LANDING TO C
LUM
N
HOR
R.
FINISH SECOND FLOOR 7
31/4"of BEARING / THICK SLAB
(I)-#6 BARS CONT
L 1 %IN
LV.
BLOCK TOP COURSEHAMBRO STL. J01 �
w \ W - N
2 SPLIT COUR h w
W -j p •
J A J
o
4 O CAVITY CAP I/
o ro
CM
m _
m n
Party Wall Detail at 2 nd Floor
SCALE: I1/2 1' O" e
o 01)
rr
APT. FIN. FLOOR
-- - ao
NOWN /
WHERE S ��/
ROOF VEEE
-� 5N
PRE -ENGINEERED ROOF TRUSSES
at 24O/C
LOCK- - ANCHOR EACH TRUSS, EACH END
8 "x 17 CONC TIE BEAM w/(4) - # 5 BARS CONT
RAISE BOTTOM OF BEAM 2" IN WINDOW AND DOOR OPENINGS
8"x8"x 16" CMU
I "x 2" PT FURRING 24 "0/C
1" FIBERGLASS INSULATION BATTS BETWEEN FURRING,
1/2" DRYWALL
— 325 LB. FIBERGLASS SHINGLE ROOF
W/ 30 LB. DRY -IN FELT OVER 5/8" CDX PLYWOOD SHTNG.
\ `\ 12
14
5/8" FIRECODE TYPE "C "DRYWALL
EACH SIDE OF TRUSS AT PARTY WALL \-\
FIBERGLASS INSULATION BATTS, OR 4EQQU.AAL.�R-30�
-5/8" FIRECODE TYPE "C" DRYWALL
WOOD BASE
THICKEN SLAB TO 5"
AS SHOWN
3" CONC.
SLAB w/ 6x6::
8/8 WWF
THICKEN SLAB TO 5" AS SHOWN
3000 PSI
CONC.
C
-s -HAMBRO
JOISTS, SEE SHEET
A-6 —
'J
'-- -7/8"x
25 GA. GALV STEEL FURRING
CHANNEL w/4A18 GALV STL. TIE WIRE
- 8'x 15 1/2" POURED CONC.
INTERMEDIATE BEAM
-- 5/8"
FIRECODE TYPE "C" DRYWALL
w/(4) - #5 .BARS CONT.
DROP TIE BEAM IN
WINDOW AND DOOR OPENINGS
� 4"STEP
F 11/2" SLOPE _
8"x 8 " x 16 " CMU
I"x 2" P.T FURRING 24"O/C
I" FIBERGLASS INSULATION BATTS BETWEEN FURRING
1/2 " DRYWALL
WOOD BASE
14"x 20" CONCRETE FOOTING w/
(4) - #- 5 BARS CONTINUOUS
4"CONC. SLAB w/6x6::10110 WWF
OVER 6 MILL VISOUEEN VAPOR BARRIER
J
CLEAN COMPACTED FILL
TERMITE TREATED
Building Cross - Section
SCALE- 3/8 1'-0"
-5
CORIAN WINDOW SILL, OR EQUAL
4� II„ L 5r-4n
8"x 8" FILLED
• III 11111 Ill
_p 40 GAL.
_ LO-BOY
�\ WH JBOVF
• _ DRYER
286SELF-L-E VER PANEL
NOTES DOOR 'OCATION
VARI SEE
SH T A -I
-rWASHER
• I •
LLI w/(I) - # 5 BAR VEI
• P
= V•
F(2)-/ 3'x2"x 3/16"
54"LONG, SET IN
MORTAR JOINT
CUT VERT.(3") FLAA
BACK 3"EA. SIDE.
�8"x 16" COLUMN BLOCK AND 8"x "HALF BLOC1wer
ALTERNATE DIRECTION EACH COU�S£, REINF.MN BLOCK w/(2)- # 5 BARS VERTICAL
w/(3) -#5 BARS VERT. AS SHOWN.
St 'r n
4'-3 I/2" 6.'- 11/2 " 10' 3"
7 TREADS at 10 I/2" I 5 I/2'THICK P UR D CONC. SLAB w/#5 B RS at
6'0/C EACH WAY IN CENTER OF SLAB_
3/8"x 6"WELD PLATE ST IN 3/4"STEP `\
FRONT EDGE OF BEA FOR '..
STAIR ATTAEDGE ME - -r •T•�-•T• T� r" T� -ram p
CONC. BEAM w/
8"x 12" BEA OURE ~ (4)- #5 BARS
� w/ S T
/ INTEGRAL B CONT.
I/2" ANCHOR BOLTS INTO GLUM S 5/8"PLYWOOD Sf EL ABOVE
2 EACH CORNER STEEL ANGLES
CIOx 8.4 STRINGERS EACH SIDE
3
LANDING
C 8x8.5
tu
ti
-_
PRCFABRICATED METAL STAL
y
POUR' TREAD PANS w/ CCWC.
W
THICK CONC. SLAB
- V0 I � - SEF- SHEET
- 12..
OD
O
/#4 BARS at 6'O/C E. ..
.
F D.Z �T A 17- DE.TA I L
..
m
p
IN MIDDLE OF SLAB.
N
-8"
3
FINISH GRADE
—
—r
STAIR TOWER FTNG.
SEE FOUNDATION PLAN
-
THICKEN EDGE I2"x 12 "
Sectio 3
A'S
Note / See sheet A-l2
for revised stair details
Stair Tower Detail
SCALE 3/8"= I'-0"
1 "x 8 " R. S.
CEDAR FASCIA
I "x 2" R. S
CEDAR DRIP
SEE DETAIL
12
_5 TOP OF TIE BEAM
-
UPSOM SOFFIT w/SCR. VENTS
5'-0" OVHNG.
O
�o
- 42" HIGH ALUMINUM RAILING
w/ PICKETTS 6"0/C.
" STEP _
CANTILEVERED BALCONY, SEE SHEET A - 6
II/2"SLOPE-> FOR REINFORCING
N
5,-0"
4"STEP
FINISH GRADE
I I/2SLOPE-').
0
W)
FIN. SECOND FLOOR
I�,I:V►S��r
ST. LUCIE COLINTY
BUILDING DIVISION
REVIEWED
FOR CODE COMPLIANCE� ,,,,� pppp
REVIEWED BY A) P"f OATS-L-�6Q-`bb-
PLANS & PERMfi'
MUST BE KEP"f ON JOB
FIN, FIRS FLOOROR NO INSPECTION' `A11LL BE MADE
aun�peon CAxn91F,1 on%`�
a
c
v
:3
EE
o
J
E
a
v
•v,
�
a
�
W
N
~ Q
W
W
' E
I
a' 5 /SAKS V.//'2 bloc las 3"
Thlc'Ke.nce Edge "A„
'.,-k0.17c Slcrf` :,B„
cr I A I '
�i
_ (41+-RS /SAZ5 W1 Z gGors5 1_3o"
C:d EL:7`,
00
141
m o
C. 0.
sr- 11 %4" 57'- 0 r/2 ••
r O
C �7
a 6 B m.o.2/I C C.' 2, 4' O, , e, 6•-8•,
N I I I
I I.
'G I 4" CONC SL,q ' II'�/6k G:: 10/10 WWF I -
OVER CLIEAP{' COMPACTED FILL
C.0. ,,
d I 10v wclov. we tub
20 -7/4 5'-4 4„HB_#ub W.C. lov. wc. lOv/Ov. wc. i
-
sink
• I sink I I Sink
• I I I I I I'
SEE NOTE AT R16NT
�• I I I I�I I
m . r a
U1 0)
/' 4^ /O' 8" G'-3" I N 4'-6" / 3' 4" / 6 3 3, 4„ 6..3„ 2:�" I _
I i I ro
..m.0. nr. 0. m.o. m.o.o c I I I j
po
I
r- - ----
�A. U 4" CONC. SLAB W/ GXG^IO/lO WWF
CONST. /T. 'h �- C. J. ,: 4 STEP DOWN FROM FINISH FLRS.
°moo. C. o. CI,-- -.- ---
51'- 11 %4•, -
I
�I
�I
I
I
C.o. I
.� NOTE: DOOR LOCATION MAY VARY WITH ALTERNATE LOCATION
OF LAUNDRY ROOM
I I
Owasher
-1 I--� I �
C. J. I Aq', -.
km 8„ - — -
sink) N ° p 2 B' I" 3' 4' 5'•2" 5'-4"
rn iz sink m. o. m.o.
_ _ " I - 1N DICATF 8"x 8" FILLED CELL w/
-- I I o I I (I)- 1F5 BAR VERT RE/NF
tn h
I I I �SiTk
sink
I fah
tub /ov. sh. I I W.0 lay. C.O. c.O. - 4"PVC SOIL LINf IOv. wc. I sh. ov. tub c.o.
4" PVC SOIL LINE
w.c W.C.
sh. N.B. a H.B. sh.l wC. N
I W I
C
WC
W.C.
lay. ] I 7 NOTE: LAYOUT DIMENSIONS I I lay. I
ay.
AORO➢POSI7EB ENOMCUBE 1Ov.
ICI I
I _ I [k-1 I
ci
I i I I I I I
a _ I INDICATES 8"x/6" POURED CONCRETE
4" CONq. A W/Gx G:: 10/10 WWF 4"CONC. 1 1 W/ 6 r 6 :: /O//O WWF COLUMN iW,/(4)- At 5 BARS VERTICAL
A OVER MEAN COMPACTED FILL �J ,; ,. L `A, f OV6R CL 1COMpACTED FILL - - ' _ -� 7k2 T1E 2401C.
- -- --- J I-- - - - _ _ - _ �/ ..
6'-2" I _ II r; 6=2" 6'-2" l I
_ ,�_—. STEP PORCH FLOORS DOWN 4" I� I
FROM FIN. FLOORS L— L---
.- - ---
__ TO SEWAGE COLLECTION SYSTEM, REFER L __ - - -- - _ __.._.- _ - _ J _ _ - _ -
' TO ENGINEERING DRAW/N65 FOR 5EWE11
Ca ", -- --
'` SERVICE LOCATION
I I
i
6, 0„ 6, 0„ 6, 0„
25'-35/8„ 2(0'_75/8„ 7S/8: 260° 24' 8" r75/g„TYF
If 1
52'- G 7/8 " I 55'- 9 //4" 52. G, 7/8 „
-
u 1G '� T— - - -� o •�` Fl NI$H GRADE
!.. __._ .._. :.__. .. �•► . z c f„�. Z'.., v, °2 h'x.7PY ty �O" O„
• a°
h,lc li tined Slab "D
IO"x 20" POURED CONC.
FTNG w/(4)-403 BARS CONT
A.
--'8"x8"x16"CMU-
4 " CONC. SLAB w/ 6 x 6:: l0//0 WW4
�— OVER, CLEAN COMPACT FILL, -----j�
-- TERMITE TR£ATfjD
o'I I
I
Footing "E "
Foundation Plan - Plumbing Plan SCALE 1/8"=1'-0"
(---SLOPE 1 1/2;.
e
a
e /
4 0
,lee
a �B"x 10 THICKENED EDGE
6„ r
I
Thickened Edge "F x
SCREENED PORCH
Foundation Details
F
l`Fvlefto✓l
ST. LUCIE COUNTY
BUILU:N(s DIVISION
REME=WED
FOR CODE OMPLIANCE
REVIEWEDBY- AV �
PLANS & PERMIT
MUST BE KEPTON JOB
OR NO INSPECTION WILL BE MADE
Alo .S*U.t uKM)I` C po�rl
_ v -SLOPE ! I/2"-hA/°� Old�f
_ A 1 �— d d '.
-- I Vista St. Lucie
4"xe" THICKENED EDGE A Condominium Community
4 St. Lucie County, Florida
i C. CALVERT MC IU MERY ASSOCIATES, INC.
Thickened Edge "G � Engineers
• PROFESSIONAL EXCHANGE BUILDING . . . STUART, FLORIDA
SIDEWALK
DRAWN BY:_ DATE: 112718E PROJECT NO. SHEET
CHECKED: SCALE: AS SHOWN
Foundation Plan • Plumbing
SCALE: /"=1".0" NO DESMIPT14 DAB Plan • Foundation Details OF
REVISIONS
TO SEWER SYSTEM
2 Bedroom B
Jgfr
2
JIN
PN 0
2 Bedroom A
Plumbing Riser Diagrams NOT TO SCALE
P"
0
fJ�N� s
2
2
�10Ifo
4" SOIL LINE
l Bedroom B
Wafer Supply Line Schedule
PIPE SIZE
HOT
COLD
FIXTURE
3/4"
WATER HEATER
WASHER
LAV.
1/2"
KITCHEN SINK
I/2"
•
TUB B SHOWER
1/2"
WATER CLOSET
HOSE BIB
1/2"
'JtN
3
, PO
2 g 2
� PJ. 001
ti LPN,
I Bedroom A
O
0
v
E
o
�
_
U
c
�O
U
O .O
O
C 5
�
U J
Q �
J� R
P
0 J'S
GGGPN
TO SEWER SYSTEM
4” SOIL LINE
2
2 Bedroom B 2 Bedroom A
JqR
Plumbing Riser Diagrams NOT TO SCALE
PJ —
S�RV� „ 9`
2 „
2
2
�PJ �PJ
G .roe
ARK .
4" SOIL LINE
l Bedroom B
Wafer Supply Line Schedule
PIPE SIZE
HOT
COLD
FIXTURE
3/4"
WATER HEATER
f12
0
0
0
0
WASHER
LAV.
KITCHEN SINK
TUB & SHOWER
WATER CLOSET
1/2"
1/2"
112"
0
1/2"
•
HOSE BIB
b
I Bedroom A
01
0
GAR PR ,
COUNTY
DIVISION
=VVED
OMPLIANCE
I'ERiVIII'
A OiN,JQB
---- -._ Vigt L BE.jy7ADE
160 ll ,
e
:03
r`
m
SEE NOTE ---
=RL=-�
r-
-_--- '' _ llt •p' I 1, �11-4, 11-4m -
1' 4"� 10'.8„ 6-3' --I -- - I _ _ 1 6-3"
, � N 4-6 3-4�
fli�o
I m.o. - -
z It
-
I .. lIDTlfAIfT. CONST. ✓T u�
i
d
i
I •M E I I
mmat
-.-._ o ID
ZaL
sink
sink
� r
tub o to
W.C. C. n.
= tub fav sh. IOV 4" PVC SOIL LINE
°p W.C.
WC. sh. H. B.
-v .O I
- 7'
W.
- law. Ali
T
a 6 4" CONG'S.LAB W/6x6:: 10/l0 WWF-' _
--� OVER $AN COMPACTED FILL
O
r--
6'-2" 6 2 y 1 6 2 L 8 2.'
co 1.4" m0. �12'0° _} mo. I L- m.o il2'-0" 2(8
mo
- ---J _ i
- _ __I_-TlTi1L[lil�Ii.
119
I
I6, O„ s: 0
IN
O E
NOTE: DOOR LOCATION MAY VARY WITH ALTERNATE __OCATION
OF LAUNDRY ROOM.
I/
-- .-- - --- M 7__ I_ L - - 4
E
-�/
- - -- --
_- :. 7tO//O
-- --C.J.44°STEPDOWN FROM-LRS. -�✓-- -_--- - i - l washer J�
-:f—l11AI1AWILJ _
m.o3,/- 2-8,8 8�-�� ml o. m o X-.•1-5 -4
2 1L {
sink
_ INDICA7 8"x 8" FILLED CELL w/
O � (U- #5 �AR VERT. REINF
� IIICCC
c� = sink
v fu
C.D. IaV W.C. - lay. C.O.
_ 4 ° PVC SOIL LINE sh' to a'
INDICATES HOSE to
BIB --� —"'sh -- w. c. -
- W.C,, _
W.C.
NOTE: LAYOUT DIMENSIONS III-+ - lav
FOR THIS CUBE SAME
AS OPPOSITE END CUBE. - -
I
�� -Em I
- /-11VDIGATf�S 8"x16" POURED CONCRETE
OVER CL _ 1 COMPACTED /F W W F-- - J %/ COLUMN Iw/(4)- # 5 BARS VERTICAL,
#2 TIES 24"0/C.
I STEP PORCH 1-
`�' FLOORS
I FROM FINISH OWN 4
ORS
TO SEWAGE COLLECTION SYSTEM, REFER TiilffTl iTQITty' _.._
TO ENGINEERING DRAWINGS FOR SEWER
SERVICE LOCATION. LC `/� C
6,
0 I
24' 8" 75/8"TYP
24-8
26-0
75/8 TYP
52'- 6
7/8"
55'- 9 1/4°
_I
52-6 7/8"
Foundation Plan - Plumbing_Plan SCALE: 1/8 1'_0"
__---- 8 "x 8 "x 16 ° CMU
�- 4 ' CONC, SLAB w/ 6 x 6:: 10//0 WWI
OVER; CLEAN COMPACT FILL,
-- -- --- TERMITE TREAT - I -
Oi E-----.SLOPE 1 1/2" E--SLOPE l 1/2"
FINISH GRADE �� e � I, -
---- - - DOWEL WHERE
k- 6' SHOWNONON PLAN
L4„x 8 " THICKENED EDGE
• .�. !� "•.• " _ ��- _ \\`` 6"x IO" THICKENED EDGE
v
4
10 x 20 POURED CONC.
FTNG. w/(4)-#5 BARS COIN - -- -----�- 12"x 24"CONC. FTNG. w/ Thickened Fdge "C" Thickened Edge "D °
I
T — -
1.I (4) - # 5 BARS CONT. SCREENED PORCH SIDEWALK
I
Footing "A" Footing 19rr
Foundation Details SCALE: 1"- l'-0"
3Y
N
S. CE
D B`r
OR NU i:-, MADE
O
_O
N
N
EU-
U
� o
J Q)
O
O
-I
Q tr
U
y
W
m �
3
W �
Uj
W
a Z o
s
Scale : I 50'
�-- S.L.F. D.D. CANAL No. 28 —
(85' R/W) \�
— Z
60.00" i
N.890 52' 00" W.
\9
6
' 1c
6 SppCE�
ES'
0 52' 00" E. 1977. 00' To Northeast Property Corner
w,�
-- 50' WIDE DRAINAGE EASEMENT �, z
YTREEATMENT
wvl
ATERIn
29
\ ACES-, '.
9
x
Al
II SPD��y
1 �
c
0
0 2
� t t
O 90' T
p 2 P Y
r W/ 2 SID
g 'U tR �
9
6N`"
J!
PAGES,
O IT
15R+ rc 5{ 44 'I
0—
2 cW II SPACES LD' 10. s
LLI
to
LJLLJ
s
J
Q 1, I
4,
C) r
- .. IZ2' 'q
LL1
5 QPcgs p''
s
yTAO SQp�
I x i
6
Qo
3
STORMWATER
RETENTION AREA
H�1 ` 114 0 _ i
m
+ 122 iq
it
I �• 1�i7' SPA*SI
WIN
DK
QP
h
v
PLANT SITE - J
- 41
0 W
� I �
a
ACES —
ISP E -- - - -
Q v \
Q) i
O / L
o
a m, 30
R N
— o0 4a — _ ✓ r
II SPACES
u -N 'j 8 3n 9`L �5 14
NS4pC
. 85' 35' W.mI .ai I ` �-
�
n SPACES 52. �k� �a� C�s 1
1141
S
N
9
Q
32
J
3-1 e
N
X"I I
a I ST. LUCIE COUNTY
' H FACE I: I ` I, I BUILDING DIVISION
I1 REVIEWED
_ 4-----'�� FOR CODE COMPLIANCE
�F N I42
A4� h I III I DATE
!1I SPAE3 1' ; I ! �i{)�, I l 1�, SPT•CO �'i I I STRUCTURAL
i PLUMBING
ELECTRICAL n
.jI SUBJECT TO: U
112 4 — 1. SOUTHERN STANDARD BLDG. CODE 1
SPACES 42. - 12. NATIONAL ELECTRIC CODE p
Ii I I N I, I 13. ALL LOCAL AMENDMENTS
3t I 1
° I DCOD
�
I
184
3
oa
y L I I
—y 63.0' _/ ' -
�
�. S. 88• o E.
214.0'
/ 125'000 G
r \ sewag Treatment an ! r I
pumping station w
w
toe of berm at pond bottom UjUj
SEWAGE TREATMENT PLANT AND 1z ,
PONDS rSITE -
U
1
1
water line--� 1 1 — - — — (T_
}I!
ST. LUCIE COUNTY •FORT PIERCE
FIRE DISTRICT 0J�],'I
FIRE PREVENTION BUREAU
APPROVED.
SUBJECT TO:/v// /` 5w-6-t/On-(i
1. SOUTHERN STANDARD BUILDING CODES,
2. NFPA NO. 101 LIFE SAFETY CODE.
Date
zj),
Fire Marshal %
ALL FIRE PROTECTION EQUIPMENT
SHALL BE APPROVED BY THE FIRE
PREVENTION BUREAU.
Notify dire PrevOti�eilg gs•
one Bur-
eau bpboc465.6655
FIRE MARSHAL
DATE InSPECTOR
Framing
Fire Stopping
--
Fire Wall
Final
CENTERLINE
CURVE DATA
No
RADIUS
DELTA
ARC
TANGENT
01
156.25'
51" 17'
139.85'
75.00'
0
526. 00'
310 50'
292. 24'
150.00' "
V
280.63'
56015'
275.51'
150.00'
®
548.42
250 05'
240.09'
122.00'
15
187.57'
71005'
232.71'
134.00'
16
701 .42'
190 25'
237.70'
120.00'
17
1606.03'
I
�— 80 20'
233.59'
117.00'
Road and Building Layout Scale:I"=50'
MAR 31332
Vista St. Lucie
A Condominium Community - St. Lucie County', Fla.
Vista Properties of Vero Beach Inc.
C. CALVEI<T 4"-FCCMERY ASSOCIATES, INC.
Engineers
PROFESSIONAL EXCHANGE BUILDING STUART, FLORIDA
DRAWN BY: DATE: 7 2 - el PROJECT NO. SMBET
LE °50GHB'
Road & Building Layout
OF
TOP OF TIE BEAM
ROOF TRUSSES
CONC, TIE BEAM
-FIBERGLASS SHINGLE ROOF OVER
5/8"CDX PLYWOOD SHTNG.
ALUM. DRIP CAP PREFINISHED(COLOR SELECTION BY OWNER)
FORMED ALUM.FASCIA
2"x10" SUB -FASCIA
.G I. I CI
VI I11.I 11I111
-- --- STUCCO
- _ 3'-0"
CANTILEVER-
5 101.
Balcony Overhang and Fascia Detail 2
SCALE: I I'-O" A -5
EE SHOyIN
NNR
gODf 0ECT lam/
i '---PRE- ENGINEERED ROOF TRUSSES
at 24 " D/C
LOCK-1,�IANrHOR EACH ?'PUSS, EACH END \\
\\ 2'k 4 LEVEL RETURN3124"OIL
PT NAILER--'
---UPSOM SOFFIT w/SCR. VENTS
1
I
I
roP Rd1/ at 36 5/8" STUCCO
-�
ky �
2 �-CANTILEVERED PARCH
b SEE SHEET A-6 FOI\REINF
i \\ 3/4"3TEP--
4 f - 11/2 " SLOPE
D
2
I
f 1
Q I 6.0"
O I
W i
h I
I
I
I
I
I
I
1
�1 4"STEP _.
1
I E-- 11/2" SLOPE
__- 12 "x 24" CONCRETE FOOTING w/
2=011 (4) - tl 5 BARS CONTINUOUS
------8"X17" CONC .TIE BEAM w/(4)-#5 BARS CONT.
RAISE BOTTOM OF BEAM 2" IN WINDOW AND DOOR OPENINGS
----`-- 8"x 8 "x 16 " CMU
---- I "x 2" P.T. FURRING 24 "0/C
-----I" FIBERGLASS INSULATION BATTS BETWEEN FURRING,
--1/2" DRYWALL_
IT - 9
I\-8"x 16" COLUMN BLOCK AND 8"x8"HALF BLOCK
ALTERNATE DIRECTION EACH COURSE, R£INF.
w/(3) -#5 BARS VERT. AS SHOWN. 8", x 16' COLUMN BLOCK w/(2)-# 5 BARS VERTICAL
Stair Tower Plan
h
W
N
01
N
Q,
0
J
h
�
a4
O
y
QC
z
q0
m
N
n'
b
o
¢
tu
\
P
60
APT. FIN. FLOOR
b
240 LB. FIBERGLASS SHINGLE ROOF
W/ 30 18. DRY -IN FELT OVER 5/8" CDX PLYWOOD SHTNG.
\\ 12
`-- 5/8" F/RECODE TYPE "C"DRYWALL _� 4
EACH SIDE OF TRUSS AT PARTY WALL
FIBERGLASS INSULATION BATTS , OR 4EQQUAAL, R�-30 �
-- -- --- - -lU tJ I� U LJ IL-/- --------
G5/8" FIRECODE TYPE "C" DRYWALL
__WOOD BASE
r THICKEN SLAB TO 5" AS SHOWN - 3" CONC. SLAB w/ 6x6:: 8/8 WWF THICKEN SLAB TO 5" AS SHOWN
\ 3000 PSI CONC.
E------------- - HAMBRO JOISTS, SEE SHEET A 6-- ----- -- -,!�_ -_ -- _ —
'�--'-7/8"x 25 GA. GALV STEEL FURRING CHANNEL w/#I8 GALV. STL. TIE WIRE
—8"x 151/2" POURED CONC. INTERMEDIATE BEAM ��--5/6" FIRECODE TYPE "C" DRYWALL
w/(4) - #5 BARS CONT. DROP TIE BEAM IN
WINDOW AND DOOR OPENINGS
----8"x 8"x 16" CMU
---1"x2" P.T FURRING 24"0/C
—I" FIBERGLASS INSULATION BATTS BETWEEN FURRING
— 1/2" DRYWALL
--- WOOD BASE
�- 4 " CONC. SLAB w/ 6 x 6:' 10//0 WWF
OVER 6 MILL VISOUEEN VAPOR BARRIER
J
CLEAN COMPACTED FILL
TERMITE TREATED
Building Cross -Section
S C A L E: 318 I_ 0 •• _. _._...--.._W___.__
-5
CORIAN WINDOW SILL, OR EQUAL
L21_ j 11
w
---. - ,
B"x 8" FILLED CELLI w/(l) - # 5 BAR VER
�IIIIIINIWUIINININ
J
1'40
I :I
DRYER.
�iilUlilB
illl�l
--_I�a
P
L
P
"x 3 116
54"LONG, SET IN
MORTAR JOINT.
CUT VERT.(3") FLAN,
BACK 3"EA. SIDE.
4'-31/2" 6.'- 11/2" 10 3"
7 TREADS of 10 1/2" 5 I/2" THICX P UR D CONC. SLAB w1*5 B RS at
6"0/C EACH AY /N CENTER OF SLAB-
(2) • I/2'� ANCHOR BOOTS SET IN \\�I Cy
FRONT EDGE OF BEAM FOR. • ' —
STAIR ATTACHMENT
CONG. BEAM w/
j B"x 12 BEAM POURS (4)- #5 BARS
INTEGRAL w/ SLAB I CONT. ----�
1/2" ANCHOR BOLTS INTO COLUM 5/8"PLY WOOD SiEL ABOVE
2 EACH CORNER III STEEL ANGLES
/ LAND/NO -7 CIOX 8.4 STRINGERS EACH SIDE
'
i
'I / PREFABRIC.ATED METAL STAINS
� POUR TREAD PANS w/ CONC. -
i
B" THICK CONC. SLAB / co
W/#5 BARS of 6' ,0/C £. o� m
1N MIDDLE OF SLAB.
GO
FINISH I I
---------- ----- -
I
FINISH GRADE
--- _ STAIR TOWER FTNG.
SEE FOUNDATION PLAN ,
___ THICKEN EDGE 12"x 12 "
Sectio
-5
Stair Tower Detail SCALE 3/8"= -0"
ALUMINUM DRIP CAP B FACIA
21.x 10" SUB -FASCIA, SEE DETAIL
z
UPSOM SOFFIT w/SCR. VENTS
5'-0" OVHNB.
TOP OF TIE BEAM
b�
-- 42" HIGH ALUMINUM RAILING
w/ PICKETTS 6" 0/C.
3/4"STEP ...._.- , -- SHEET
------ -
/---- CANTILEVERED BALCONY SEE SHEET A - 6 � FIN. SECOND FLOOR
1112 "SLOPE-4 1, FOR REINFORCING K - w - -- ---' -
- I
. F
O 8
-. -5 0 '
I �I
-4"STEP
I l/2"SLOPE-i
--FINISH GRADE
FLOOR
C3
10
L6 z
W
W
2 l)
cn O
CO
a
Q
U
N
19'2. I 16,-2 /9 -2.
3/4" STEP .\
SLOPE 11/2 y
6 -0"
6"AT BEAM
y
a:
Q
x
U
P
CANTILEVER REINFORCING
# 5 BARS 11 1 LONG at 16` 0/C
# 5 BARS B ' LONG of 16" 0/C
* 3 TEMP. STEEL of t0" O/C (14 BARS)
M -----HAMBRO STEEL JOISTS -- --
POURED CONC. BEAM w/(4) - # 5 BARS CONT.
1 '- 10 3/4 4 '- II 114
Section l SCREENED PORCH
--- a-s
1
I
" ., 26=0
24 B26:0
- - _ - - --- -- - ---- -- -- --- - -- — -- - - - -- — - - —.._ - -- - -.. - — - --- - $
Second Floor Framing Plan SCALE I/B
DESIGN LIVE LOAD:
APARTMENT FLOORS 40 PSF
BALCONY 100 PSF
TOTAL LOAD ON JOIST SYSTEM 105 PSF
CANTILEVER REINFORCING
8 5 BARS 10' LONG at 16"0/C
At 5 BARS 7' LONG at 16 0/C
# 3 TEMP. STEEL at 10" 0/C (13 BARS)
/'-3/4 "STEP
SLOPE 1 ri2"
6"AT BEAM
• • y
9EAM w/(4) - # 5 BARS CONT.1--
U
8" ~
Section A26 BALCONY
SCALE: l"= 1 '- 0 "
.00R REINFORCING
ALL CUBES)
J
I Q t!1
QO
/
zLu