HomeMy WebLinkAboutELECTRICAL SITE PLANProject: a Ih m N 0. Q n N 4 r rN- O m N W d 0 I r- I 0 m U Z In a U Zn N a 0 z w z a z w J z a Ir Q U PANELBOARD SCHEDULE " r VOLTAMP 111iES "` BUS r` AO B0 LOAD DESCRIPTION qyW; PdES AMPS x A B x AMPS LOAD DESCRIPTION Ig500 Ig500 I TOTAL CONNECTED VA SUB -TOTAL VA TOTAL CONNECTED AMPS TOTAL DEMAND VA TOTAL DEMAND AMPS SUB -TOTAL VA PANELSOARD RATINGS PANELSOARD FEATURES VOLTAGE 0120/208 10,3W ■120/240 10,3W ❑ BUS AMPS 0100A 0400A ■200A 0600A 0225A ❑-_A MAIN DEVICE ❑MAIN LUGS ONLY ■200A CIRCUIT BREAKER ❑__A FUSED SWITCH ENCLOSURE ❑FLUSH ■SURFACE ENEMA 3R EHINGED DOOR ■KEYED LATCH ❑DOOR -IN -DOOR ❑STAINLESS STEEL ■PAINTED STEEL ■NAMEPLATE BRANCH 012 ■18 024 POLES 036 042 ❑_ BRANCH DEVICES ■CIRCUIT BREAKERS ❑FUSES ❑-_TO BE GFCI BREAKERS ❑LOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) 010,000A 030,000A 065,000A 014,000A 042,000A ❑100,000A ■22,000A 050,000A ❑_.00OA ❑SERIES RATING PERMITTED ❑SERVICE ENTRANCE RATED Q1 Q2 Q3 Q NOTES NEUTRAL BUS SOS MATERIAL 050% 0200% EC=OUPER E100% ❑__% ❑ALUMINUM EGROUND BUS REQU?RED ❑- PANELS IN PARALLEL - ❑ THROUGH FEED LU aREWIRED VOLTAMP AO SO PAN. LOAD DESCRIPTION AViC ARD SCHEDULE X 8US 7 S �6Y A 8 Y AMPS Pal LOAD DESCRIPTION VOLTAMP Ala F BO euL- TOTAL CONNECTEj ,� „� 25 "" 25 �TCT I A ' DEM D I 1UUUSUS-TOTAL TOTAL DEMAND AMPS SUB -TOTAL VA PANELBOARD FEATURES SUh-TOTAL I� r ENCLOSURE BRANCH POLES BRANCH DEVICES VA TOTAL CONNECTED AMPS []FLUSH❑12 ❑36 MCIRCUIT BREAKERS []FUSES PANELBOARD RATINGS VOLTAGE BUS AMPS MAIN DE\ICaR ■SURFACE 018 ❑42 MALL TO BE GFCI BREAKERS 0120/208 10,3W E100A 0400A ❑MAIN LUGS ONLY 0120/240 10,3W 0200A 0600A ■60A CIRCUIT BREAKF ❑ ❑225A ❑_A 0e4 FUSED SWITCH ENEMA 3R ❑24 ❑- "El TAT CENTER PERMITTED INTERRUPTING RATING (AIC SYM) ❑SERVICE ENTRANCE RATED ■HINGED DOOR NOTES E10,000A ❑30,000A 065,000A NEUTRAL BUS BUS MATERIAL EKEYED LATCH Q1 014,000A 042,000A 0100,000A ❑50% 02DOX ❑COPPER ❑DOOR -IN -DOOR 02 022,000A ❑50,000A 0-.°000A E1DOX ❑_-X ■ALUMINUM ❑STAINLESS STEEL Q3 ❑SERIES RATING PERMITTED EGROUND BUS REQUIRED ■PAINTED STEEL ❑ PANELS IN PARALLEL 10 THROUGH FEED LUGS REWIRED ENAMEPLATE I Q PANELBOARD SCHEDULE ,S' VOLTAMPS LOAD DESCRIPTION q� Pas AMPSI '"` � BUSWIIES AMPS LOAD DESCRIPTION VOLTAMPS AO SO A 0 AWG A0 BO SUB -TOTAL VA TOTAL CONNECTED VA TOTAL CONNECTED AMPS TOTAL DEMAND VA TOTAL DEMAND AMPS CIIR-TnTAI VA PANELSOARD RATINGS PANELBOARD FEATURES VOLTAGE 0120/208 10,3W 0120/240 10,3W ❑ BUS AMPS 0100A 0400A 0200A 0600A 0225A ❑-_A MAIN DEVICE ❑MAIN LUGS ONLY E60A CIRCUIT BREAKER ❑�A FUSED SWITCH ENCLOSURE ❑FLUSH ESURFACE ENEMA 3R ■HINGED DOOR EKEYED LATCH ❑DOOR -IN -DOOR ❑STAINLESS STEEL ■PAINTED STEEL ENAMEPLATE BRANCH 012 E18 024 POLES 036 ❑42 ❑_ BRANCH DEVICES ■CIRCUIT BREAKERS ❑FUSES MALL TO BE GFCI BREAKERS ❑LOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) 010,000A 030,000A 065,000A 014,000A 04Z000A 0100,000A ❑22,000A 050,000A ❑_,000A ❑SERIES RATING PERMITTED ❑SERVICE ENTRANCE RATED ( Q Q3 QQ NOTES NEUTRAL BUS 050% 0200% ■100X ❑_�6 BUS MATERIAL ❑COPPER EALUMINUM ROUND BUS REQUIRED ❑ ___PANELS IN PARALLEL 10 THROUGH FEED LUGS REWIRED EXISTING FPUA PAD MOUNT TRANSFORMER i DRY TYPE TRANSFORMER - 37.5kVA, 4BOV, 1 # TO 12D/24OV, 1#, 3W IN NEMA 3R CABINET SERVICE DISCONNE CT PROVIDE MAIN BONDING JUMPER 1M2 100 0 CONNECT PANEL PROVIDED WITH CONSTRUCTION TRAILER 120/24OV, 1#, 3W, 125A T r--� I I N S n II I I I uI 1 1 /2"- 3,1'1+6G 1 1/2"-3#1/0 (AL) L1"-2#3+6G L2'-3#3/0+6G RUN THROUGH METERING CTs TEMPORARY POWER RISER DIAGRAM SOURCE = 4SOY/277V, 3�, 4W 1"-3#5+BG 1"-3#6+BG ELECTRICAL NOTES THESE NOTES APPLY TO ENTIRE PROJECT: A. CODES. ALL ELECTRICAL WORK SHALL COMPLY WITH THE DRAWINGS AND SPECIFICATIONS, THE NATIONAL ELECTRICAL CODE AND APPLICABLE LOCAL CODES, WHICHEVER IS MORE STRINGENT. 8° POWER COMPANY. THE ELECTRICAL CONTRACTOR IS TO COORDINATE ALL SERVICE REQUIREMENTS WITH THE POWER COMPANY BEFORE BIDDING TO BE CERTAIN ALL WORK NECESSARY TO MEET POWER COMPANY SPECIFICATIONS IS IN THE BID. ALL ELECTRICAL GEAR SHALL BE APPROVED BY THE POWER COMPANY. THE ELECTRICAL CONTRACTOR SHALL MEET WITH THE POWER COMPANY PRIOR TO BIDDING TO DcTERMINE ALL FEATURES, FUNCTIONS AND LOCATIONS OF SERVICE FURTHERMORE, THE ELECTRICAL CONTRACTOR IS TO MAINTAIN CONTINUOUS CONTACT WITH THE POWER COMPANY DURING THE PROJECT, AND IS TO NOTIFY THE ENGINEER IMMEDIATELY OF ANY CHANGE PROPOSED. THE ELECTRICAL CONTRACTOR SHALL (X)ORDINATE THE SERVICE THOROUGHLY AND DOCUMENT THE COORDINATION. C. SCALES. DO NOT SCALE OR TAKE DIMENSIONS FROM ELECTRICAL DRAWINGS. D. GFCI. OUTLETS INSTALLED OUTDOORS, WITHIN 6° OF A SINK, AND OTHERWISE REWIRED BY CODE ARE TO BE ON GFCI TYPE CIRCUIT BREAKERS. APPLICABLE BUILDING CODES FLORIDA BUILDING CODE, 6TH EDITION (2017) NFPA 70, NATIONAL ELECTRICAL CODE (2014) FLORIDA FIRE PREVENTION CODE, 6TH EDITION (2017) FLORIDA ENERGY CONSERVATION CODE, 6TH EDITION (2017) MATERIALS AND WORKMANSHIP SHALL COMPLY WITH ALL APPLICABLE CODES AND ORDINANCES IN THEIR LATEST REVISIONS. CONTRACTOR TO COORDINATE SPECIFIC REQUIREMENTS OF EQUIPMENT WITH MANUFACTURERS' SHOP DRAWINGS. ALL EQUIPMENT SHALL BE INSTALLED STRICTLY IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS. I i l l I a I EXISTING FPUA PAD MOUNT TRANSFORMER l I I l SERVICE TOEXISTING FPUA TRANSFORMER -- tttttl.l'I ' t CONNEX BOX CONSTRUCTION -� NEW MAIN TRAILER- - TRANSFORMER II, -- - PANEL 'T 1 � 1 Ed - 44 ° I I I V i I {{ I r I i :777177 r ' It I h C�•LJ PAN E4 N 0 I 7" ` II t 4 1 � - _ - �.1 d r' ' J 17 -d- J _r L JJ , it P J, PANEL S '•' /`"/ / , T"" ' // 77 /. i x- ~ /-47,///!!! -. - /, T. 7-,1'7 J ' / 7 ITT 71/7-7 l z-, .�. -7 l� J�-,r IA IL ! ALL J.J / /1./ // "/! /f-Gj/ / ''/ /d / %- ->`rr�---'`1�� -/. "tT�` • . i -.. -�_ 1 R -- rFI , s r � h \ -N f a \ I �.-- -- I__ ------IL Vjm ELECTRICAL SITE PLAN � Callbeorreyo�dig. N � S SCALE : 1" = 50'-0" TEMPORARY CONSTRUCTION POWER FOR FUR51JIT 50AT5 5901 5T. LUCIE DLVD. FORT FIERCE, FLORIDA Key Plan \ \\\11111111 7 • FR ���i \\ 0 L // L , STATE Of _� ``///SSONA �55Ue5: No.: Date: DeScri Lion: Architect: DONADIO & Associates, Architects P.A. 619 17,h Sma.t VeroB xh 14-104A) 'J 772 794-N29 V.x 772-562 HMNI mww.tltmu,hu �nitctn, !'on5uftant: CARDInRL 675 NW MERCANTILE PLACE SUITE 2D6 PORT ST. LUCIE FL 34986 T.561.746.6343 F.561.746.3602 irTFo@CEAengineers.com CA LIC. 31555 ✓rawing Title: 5iTE PLAN MD9 DU3a Job Nc^t:'1 SC�i�rAWD �Ilf`ePYii11111i1/ Drn: PrawH6 91c: rho: XREF Flk: PL Project No.: P:ot Fire: 2011542 5hee; No.: ,m No.: atec-pneo: E-01 0= 1