Loading...
HomeMy WebLinkAboutPLANSAerial View: Plan View: REVISIONS: Location Map: Index; C-1 I., COVER El R.A ELECTRICAL DIAGRAM & CALCULATIONS S-1 I.g STRUCTURAL DIAGRAMS S2: STRUCTURAL CALCULATIONJ M a) oc) _ N Q � co CcJ C 7 L.L O a) c- c .� W > J f0 U 0 a> W w o U) (n I M O IL O M O N 00 Q) qq- } M � _j Lp LL 0) OMCD > U > Lo L (omo0 LL1 > 00 c) L " ) op 00 ry 0 t, ,cam �,� •a, ; iZr _Sr` O~ Q //// • 1bEJ����CC N M M 2 N O N H W rn tyj*W �nm0 a0QW=w W C6z > ~ = W U u, LL WNM�HILZ LLv=02 W U u. QWMaI'25 0 Sol W E U. U O J LL DATE: 8/22/2019 SCALE: NTS DRAWN BY: J.B PAGE: cmi e SYSTEM DESCRIPTION CODE SUMMARY m GRID -TIED PHOTOVOLTAIC SYSTEM STATE BUILDING ELECTRICAL (8)AP SYSTEMS QS1 MICRO -INVERTER --� - a (32) S-ENERGY 305W MODULES FLORIDA 2017 FBC, 6TH 2O14 NEC Y SYSTEM (32) PHOTOVOLTAIC MODULES ARE CONNECTED INTO (8) MICRO -INVERTER • (8) MICRO -INVERTER CONNECT INTO (3) CIRCUIT OF (2&3) MICRO -INVERTER WHICH FEED (3) 2-P 240V 20A CIRCUIT BREAKERS ® TOTAL PHOTOVOLTAIC SYSTEM STC RATED DC ENERGY POWER PRODUCTION OF 9,760 WATTS INVERTER HAS MAXIMUM POWER POINT TRACKING (MPPT) INVERTER MEETS REQUIREMENTS OF 3-P POWER INVERTER MEETS IEEE 1547 INVERTER MEETS U11741 • ALL ELECTRICAL EQUIPMENT INSTALLED ARE UI., LISTED FBC ADMINISTRATION CODES NOW IN EFFECTNEC 2014; FBC 2017" F 1 FBC ADMINISTRATION "ALL ELECTRONICS, SOLAR PANELS AND ASSOCIATED ELECTRICAL EQUIPMENT TO BE INSTALLED ARE UL LISTED." SYSTEM AUTOMATIC OPERATION 1. GRID POWER IS PRESENT, PHOTOVOLTAIC SYSTEM FEEDS THE LOAD AT DAY TIME,. 2. GRID POWER IS LOST, PHOTOVOLTAIC SYSTEM AUTOMATICALLY DISCONNECTS FROM TIC; GRID. 3. PHOTOVOLTAIC SYSTEM WILL AUTOMATICALLY RESUME FEEDING POWER TO THE GRID. WHEN THE PROPER GRID VOLTAGE AND FREQUENCY IS RESTORED (IEEE STANDARDS) AND THERE IS ENOUGH SUNLIGHT PV Array I� III Micro Inverter Point of Utility Connection (see options) 0 Revenue Me Item Manufacturer Model Listing / Compliance PV Modules S-ENERGY 305W UL Inverter AP SYSTEMS QS1 UL All disconnects AP SYSTEMS DC & AC UL All overcurrent protection AP SYSTEMS DC & AC UL FSEC CERTIFICATION # S-ENERGY AP SYSTEMS 305W QS1 RV-16-0106A NeSmFOLAR M BONDING CONNECTION GROUND PATHS: AS 7� MOUNT INSTALLATION GUIDE PA6 7 I I AV ass S-Energy Monocrystalline PV Module S��`> SNM SNM SNM SNM tn`Y ----------- _____________W______.W__-------------------- ___r_---------------- _----------- _------- Electrical Characteristics Rated Power (iPd4 Voltage at Ran, (Barnet Current atd?:(hnp) Warranted Minimutm,5k _............ Short -Circuit Gurriousup Open Circuit Voltagri Module Efficiency .... Operating Module Temperature Maximum System Voltage Maximum Series Fuse Rating Maximum Reverse Current Power Tolerance 395W 295W 305W •, 306W 32.OV 32'.4V 32.8V 33.2V 9.05A�9.10A 8.14A ---- 9.18A - ---------- 305W - ---- 295W 305W 305W 9.63A 9 66A 9 68A _ - 9.71A 396V 397V 1 399V 40.1V 17.8% 181/a 1 18.4/ I 18.7 /0 -40°C to + 851C -- - 1,000VIIEC) 11,000V(UL) - 20A 20.25A 0-+5W NH1NerD EX I ERNAL LOAD I IMPACT SadwLfi.d: s,aadv ,3ar aaaa Ra loop W a L d i g 400 p I30 5,a00 Pa (a0 Had impact �30] (spend 11 990 JUNCTION BOX Mount to, hole BEA 6^ IF ONE fide of BEA 8.5 T ---- Temperature Characteristics Temperature coefficicurl1 0.046 %/'C Temperature coefficient sf V -0.282 % /'C Temperature coefficient of power -0.394 % I rC _.. ca no ry_ NOCT(T20`C - o n a: Wind Iris). -./ 45+2 'C Packing Configuration 30T 40T Container _ 40' H!C 40' H1C Modules Per Pallet 25pce 25pcs m: Pallets Per Container 28pailets 28paliets 1 Modules Per Container 700pes 700prs Remarks : ai-,S nrlalt ,A lz 1­r , SS,c a v e'.' , z - i, f i .o, S rV v u 0 N _. b 1- E'y Ar C 1 N S-Energy Co„ Ltd. end FI. Miraeasset lower, 20, Pangyoyeok-ro 241beon-gil, Bundari Seongnam-sI. G,veonggl do, KO: EA 1S4£4 Tel. +82-70-43 r1QC Fax. 8270-43390 9 E-mail. nLi i, serer "�Y� gY .com SEAT America, Inc. 20 Gorporkre i a k A'U fis 190 Wire CA 02606. US.A. Idea. sP,crdy Amen al Tel. -1949-281 89 Fax '1940281-7893 E-mail, es us is eregy com S-Energy Japan Co., Ltd, 1 -6c. Koojfn ach CiTyada-W Tokyo, D K Koil na hi building 3F A J ?an Tel. 8'I-3-626a75£I Fax r813 6261-3769 E-mail. tL L gas ..a(aIs enagy.com SAFETY LABELS PHOTOVOLTAIC POWER SOURCE AC OPERATING VOLTAGE 240VOLTS AC OPERATING CURRENT=AMPS MICROINVERTERS LOCATED UNDERNEATH MODULES FOR SERVICE CALL (PV COMPANY &7 LABEL FOR EACH J-BOX LABEL SIZE: 4" x 2" NOTE: INSTALLER MUST FILL IN AC OPERATING CURRENT ON LABEL. BONDING MIDCLAMP ASSEMBLY ENDCLAMP ASSEMBLY BONDING RAIL SPLICE BAR RAILTO L-POOTwBONDING T-BOLT Stainlace steel Mauling points, 2 per module, piano module frame anodization to bond Serrated flange nut bonds aluminum Endttamp to stainless steel T-bolt Stainless ,test self dolling screws doll antl tap ' into splice bar and rail creating bond between Serrated longs nut removes L-foot anodization to bond L-Froth stainless steal T-bolt module to module through damp 5enatetl T-bolt head rp to splice bar and each mil section .,^� penetrates rgroun led Serrated x,ft,olt heanut, Serrated f4�nge not bonds stainless sisal clamp Endtas grounded to bond T-bott, nut, and Entlrlemp to grounded and s Aluminum splice bar spans across rail gap to and Bems ro bond Y Iwlt, nut, and L-fool to grounded S to stainless steel 1'-bolt SM it g create rail to mil bond Rall on at least one side rail Serrated Track head penetrates it anodization _4°r' 1r, of splice will be grounded. ie bond T-bole nut, clamp, and modules to cart "^i "'illin hill grounded SM rail. " PHOTOVOLTAIC MICROINVERTERS �s tp p LOCATED UNDERNEATH a}015MICa0NV#InR ; ,g 111 �, �� tt �� � PV MODULE ON ROOFTOP ARRAY muuar '1 tL . �Fi '>_sk ��... " SA. ;ak l FOR SERVICE PLEASE CALL (PV COMPANY#) BONDING MICROINVERTER MOUNT RACK SYSTEMGROUND Hex not with glock washer bonds metal WEEB weather dimples pierce anodized mil to m m «nverte RPtaudge to stainless steel T bolt oreate bond belweeo Tull and lug Berated T bolt head penetrates mil eradication S"3 Solid mppor wire connected to lug is routed to to bond T bolt nut antl. Later en grounded SM mil 4;a_ caul (naiad{rfi .rya .. m.b.iw, ' provide final system ground connection, d q se ad >min iirr 8.;,'d p,ni. IJ.n'I a+ao d:n spaoyAi vcmi iamr"Asmv .,_ .• sear S>Hjr, credit r, r The I\FC orves you the choice of tom methods for ensurin electrical co thi at stivme equipment sci fee rac eyes sad service conductor enclosures(250926m) 113omhnr junipers Bond metal parts to the service neutral conductor. This requires It main boudnngjumpei lz50.24(B) and 250.28). Because lire Service neutral conductor prm ides the effi sine grotmd-fault currentpath to the power supply (2503402)j, you don't have to install an equipmentgrounding conductor within PVC conduit conlaunmg service -entrance conductors [2aG.14_(A)(!) and 152.v. d Le uj. d Fhreoded ittards 'terminate m .talraeewal s to metal enclosures by threaded hubs on enclosures Ni' made wrenchtight). 3.Threudlr ss jir`Ro s femmnate metal raveyvays to metal enclosures by threadless luting, (if made tight) 4 Othet llshd der Tees.'These include bonding -type locknuts, bnshnigs, wedges, or bushings wuh bondingjumper9. It 1l • f 8 ! i M AM-Mw ■ 2 c i• •' i * far BONDING idlIDCLAMPASSEMBLY Stainless steel Midclamp points, 2 per module, NOTE: pierce module frame anodization to bond (8) MICRO -INVERTERS TOTALAMPS: 40A module to module through clamp. TOTAL 2P 240V 20A BREAKERS: 3 Serrated flange nut bonds stainless steel clamp SYSTEM TOTAL BACK FEED RATING: 60A to stainless steel T-bolt Serrated T-bolt head penetrates rail anodization ELECTRICAL BREAKER RATING: 200A to bond T-bolt, nut, clamp, and modules to ELECTRICAL PANEL RATING: 200A grounded SM rail. LABEL FOR SOLAR AC COMBINER BOX LABEL SIZE: 5-1/2" x 2" PV SOLAR BREAKER DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL FOR SOLAR CIRCUIT BREAKER INSTALLED IN MDP LABEL SIZE: 2" x 1 PHOTOVOLTAIC SYSTEM COMBINER PANEL DO NOT ADD LOADS LABEL FOR SOLAR AC COMBINER BOX LABEL SIZE: 4' x 2" z�, A, CAUTION SOLAR POINT OF CONNECTION LABEL FOR MAIN DISTRIBUTION PANEL LABEL SIZE: 4" x 1" ® WARNING DUAL POWER SUPPLY SOURCES: UTILITY AND PV SOLAR ELECTRIC SYTEM LABEL FOR MAIN DISCONNECT OR METER LABEL SIZE'. 4" x 2" PHOAC TO DIOSCONNECTTEM/L ZL PHOTOVOLTAIC SYSTEM EQUIPPED `- AD OPERATING VOLTAGEE::��VOLTS WITH RAPID SHUTDOWN AC OPERATING CURRENT AMPS ---- NEC 690.12 LABEL FOR SOLAR DISCONNECT LABEL FOR SOLAR DISCONNECT LABEL SIZE: 4" x 2" LABEL SIZE: 4" x 2" NOTE'. INSTALLER MUST FILL IN AC OPERATING C'JRRENI' ON LABEL. NOTE FOR ALL LABELS'. LABELS SHALL BE UV RESISTANTAND SHALL, HAVE WHITE LETTERS ON A RED BACKGROUND. SHARPIE EXTREME OR EQUIVALENT UV RESISTANT MARKERS SHALL BE USED FOR WRITING ON LABELS REQUIRING INSTALLER -WRITTEN VALUES. Grid voltage: 1-240 V !NF'UT l[VOA fD MPPT Voltage Range 22V-48V 32x S-ENERGY 305W (PV-array 1) Operation Voltage Range 16V-55V Maximum Input Voltage 60V Inverters: Startup Voltage 20V 8 x QS1 - 240VAC (Inverter efficiency: 95 %) Maximum Input Current 12A x 4 Maximum DC short circuit current 15Ax4 Evaluation of design 240V 208V Maximum Continuous Output Power 1,20OW 1,100W Nominal Output Voltage/Range 240V/211 V-264V 208V/183V-229V Ambient temperature: Nominal Output Current 5.00A 5.29A Record Low Temperature: 35.00 OF Nominal Output Frequency/Range 60Hz/59.3Hz-60.5Hz Average High Temperature: 78.00 OF Power Factor >0.99 Part project 1 Record High Temperature: 98.00 OF Total Harmonic Distortion <3% �- Inverter: 8 QS1 - 240VAC EFFICIENCY Peak Ef?ciency 96.5% PV-module: A: (Piro -array 1) Nominal MPPT Ef?ciency 99.5% S-ENERGY Night Power Consumption 30mW 305W _ Mounting type: Roof Operating Ambient Temperature Range -40'F to +149°F(-40'C to +65'C) Technical data Storage Temperature Range -40'F to +185`F(-40"C to +85'C) PV Peak power: 9.761 Dimensions (W x H x D) 11.V x 9.1" x 1.6"(281 mm x 231 mm x 41.3mm) Total number of PV modules: 32 Weight 9.91bs (4,5kg) Number of inverters: 8 Max. DC power: 330 W AC Trunk Cable Maximum Current 20A Max. AC power: 230 W Enclosure Rating NEMA 6 Grid voltage: 240 V Q Cooling Natural Convection - No Fans Nominal power ratio, 95 % d' r� yv, Input A: PV-array: PV-array 1 Communication Wireless (Zigbee) Transformer Design High Frequency Transformers.. Galvanically Isolated Number of Inverter: 8 Monitoring Via EMA" Online Portal Number of PV modules: 32 Peak power (input): 305Wp Warranty 10 years standard. extendable to 25 years MPP PV voltage: 32.6 V Q OC PV voltage: 40.0 V Q CERTIFICATE COMPLIANCE Min. DC voltage (Grid voltage 240 V): 22.0 V Max. PV voltage: 40.0 V Q Safety and EMC Compliance FCC Part 15:ANSIC63.4JCES-003 Max. DC voltage (Inverter): 48 V Certi?cate & Compliance UL1741" CSAC22. 2No.1 07.1 -01, Max. current of PV: 9.83 A Q Grid Connection Compliance IEEE1547 Max. DC current: 15.0 A Rapid Shutdown Meets NEC 2014,12017 690.12 "- Meets the standard reav remaus for Distributed Energy Resources PV/Inverter compatible R- (UL 17c1) and idenV^ed with the CSA Listed Mark ,,�; i PV array and type of inverter are compatible. The SpecOra[ons subject to changO witbaut nohce -please ensure you are 1.6.19 G All Rights Reserved nominal power ratio (max. DC power of the inverter using the most recent update found at vranv.APsysteirs coin - - divided by the peak power) is within the recommended AP �' n s .....,..-v.. .. range (80% - 120%). A, E N r-HGY n0 A E Rdown 004 ,... 1 NOTE: PER FL. STATUTE 377.705 (REVISEL) 7/1/2017), 1 MANUEL E. SIQUES PE #20233 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. #8 Bare Copper Ground Wire 1" PVC SCH80 CON[ 6 #10 THWN-2 1 #8 THWN-2 GROI SYSTEM RISER WIRING DIAGRAM I EQUIPMENT LOCATION 1 2 3 4 5 6 7 8 9 10 11 12 t- t r t- t 7 ++ 7 t 7 t 7 t 7 t 7 t- t r NOTE: LINE SIDE TAP MAX RATING MAIN SERVICE ENTRANCE CONDUCTOR SIZE (PV)AC DISCONNECT SPECIFICATIONS (MINIMUM 60AMP RATED PER NEC 230.79(D) TAP CONDUCTOR SIZE (MINIMUM 6 AWG COPPER OR 4 AWG ALUMINUM PER NEC 230.42(B) AND 310.15(B)(7) OR 310.15(B)(16) CONDUCTOR ROUTING IN RACEWAY AND INSIDE PANELBOARD INCLUDING THE GROUNDED CIRCUIT CONDUCTOR (NEUTRAL) PEF NEC 300.3 AND 250.240. TAP CONDUCTOR LENGTH LIMITATION OF 10 FEET PER NEC 705.31 GROUNDING AND BONDING CONNECTIONS FROM THE (PV) AC DISCONNECT CONNECTION TO THE SERVICE PANELBOARD, AND GROUNDING ELECTRODE CONDUCTOR AS APPLICABLE. AP SYSTEMS Microinverter TYP. v,�,.�, C AC INTERCONNECT CABLE ATTACKED UNDER MODULE A NEC 690.12 CODE COMPLIANT ROOF ARRAY NOTE: EXXIISTING METER WILL BE CHANGED 1" PVC SCH40 CONDUIT ALL LOAD CALCULATIONS FOR THIS PANEL TOANET METER BY FPLAFTER THE 2 #6 THWN-2 1 #6 THWN-2 NEUTRAL HAVE BEEN DONE AND THIS CHANGE WILL NOT EXCEED CODE. FINAL INSPECTION i 1 #8 THWN-2 GROUND NOTE: SOLAR 1" PVC SCH40 CONDUIT COMPLIANCE WITH NEC 250.58 ELEC, PANEL 2 #6 THWN-2 EXISTING ONLY ONE GROUNDING ELECTRODE 240V 100A 1 #6 THWN-2 NEUTRAL MDP EXISTING WIRING FOR ALL ELEC. EQUIP. CONDUCTOR 1 #8 THWN-2 ROUND 240V 200A 3 3/0 THWN (NOTE: LINE SIDE TAP CONNECTION IN MDP WITH PIERCING TAPS BETWEEN METER 240V 60A 200A METER LOAD SIDE AND EXISTING MAIN DISCONNECT SOLAR EXISTING NOTE 020A FDISC U ED ! ------I SERVICENEC 690.12. CODE COMPLAINT 240V 200A N240V 60A� Lt L2SERVICE L2 EXISTING i 5/8" GROUND ROD EXTERIOR OF BUILDING INTERIOR OF BUILDING EXTERIOR OF BUILDING REVISIONS: Z O J M 600 U a) U) >rn Q M Q U J 06 LL C.(I) a) Q J M U ~ Q L) () J LU Q O U) U) a- ItT -tf J �a U_ U W J W 0 CO N � �CO� U) U-) LL G)i > U CO L 0 M Ln U mmoU W 00 U) C0 0) 00 00 Ad a III IIII111 M M N C) N H W rn LLiF- (o CL(n oU) =U C Z>~ W LU W Z fn _1.2 � H W O Jz�,�=0� WOt:=J~OUW Z W,I-l_L>- - QQeMQ F-JC� �0Co� WL=W L' O U J LL DATE: 8/22/2019 SCALE: NTS I DRAWN BY: J.B PAGE: E-1 S-ENER J6 305W i I i ,- i I I I I I � � Ili i p I I • I • I ! I I II ROOF MOUNTS TYP. SOLAR MODULE! T r-. " I I ALUMINUM ROOF MOUNTS MEASUREMENTS PHOTOVOLTAIC POWER SOURCE AC OPERATING VOLTAGE 240VOLTS AC OPERATING CURRENT=AMPS MICROINVERTERS LOCATED UNDERNEATH MODULES. FOR SERVICE CALL (PV COMPANY #) LABEL FOR EACH J-BOX LABEL SIZE: 4" x 2" NOTE: INSTALLER MUST FILL IN AC OPERATING CURRENT ON LABEL. PHOTOVOLTAIC O LOCATED UNDERNEATH ® MODULE ON ROOFTOP ARRAY - SERVICE PLEASE CALL (PV i LABEL FOR SOLAR AC COMBINER BOX LABEL SIZE: 5-1/2" x 2" PV SOLAR BREAKER DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL FOR SOLAR CIRCUIT BREAKER INSTALLED IN MDP LABEL SIZE: 2" x 1 PHOTOVOLTAIC zk� AC DISCONNECT W-\ LABEL FOR SOLAR DISCONNECT LABEL SIZE: 4" x 2" NOTE: INSTALLER MUST FILL IN AC OPERATING CURRENT ON LABEL. M LABEL FOR SOLAR AC COMBINER BOX LABEL SIZE: 4" x 2" z�, A CAUTION SOLAR POINT OF CONNECTION �ti . .I ® WARNING A� DUAL POWER SUPPLY SOURCES: UTILITY AND PV SOLAR ELECTRIC SYTEM LABEL FOR MAIN DISCONNECT OR METER LABEL SIZE: 4" x 2" NEC 690.12 LABEL FOR SOLAR DISCONNECT NOTE FOR ALL LABELS: LABELS+ RESISTANT ♦ i SHALL HAVE WHITE LETTERS ON A RED BACKGROUND, - s ELEC. & DISC ` MET t ,� .. MDP k H ALLOWABLE Load: (5400Pa) 113 psf 39.34" NOTE: Install mid clamps between modules and end clamps enI AD nnnr,i II C: at the end of each row of modules. NOTE: ALUMINUM RAILS SHOULD ALWAYS BE SUPPORTED BY MORE THAN ONE FOOTING ON BOTH SIDES OF THE SPLICE." ROOF AREA EXISTING SHINGLE ROOF TOTAL ROOF AREA: 3,574 sq.-ft TOTAL PHOTOVOLTAIC AREA: 774 sq.-ft PERIMETER WIDTH: 4.3' PRESSURE ZONE: 1 & 2 MEAN ROOF HEIGHT. 14' ROOF SLOPE: 3:12 TOTAL MODULES: 32 MIN. ROOF MOUNTS: 64 TOTAL POINT OF CONNECTIONS PER MODULE: 4 ALUMINUM RAILS: 2 co ¢v D J p a) i a J -J co U J W LU o CO a W U) CO O I I O M O N CO N l ..//�� c / A l'1 J LO N LL O > U OCO L0 L W �; (C)CO oU W 00 C 0 O V) A �a'otiM� M M N O N L- W 0 W U F �- tnQMtOU) W fn LU W> a'MtiHZ iY M ~ qq CO = w 0 W L— M ^ W W N MOH d Z JZ`-Lei==2LU LU OZtn — LU>- ZLU I-LL>- aaMa I=�CY �cooXOW EE WLLar U J LL DATE: 8/22/2019 SCALE: NTS DRAWN BY: J.B PAGE: smi IRON RIDGE XR100-RAII-SPAN TABLE {Inches) FOR 72 CELL MODULES (EXPOSURE C) ATTACHMENT DIAGRAM REVISIONS: . , 60PSF - 70PSF 2 ROWS OF RAILS PER Pz1 Pz2 Pz1 Pz2 Pz3 MODULE 49 49 XR10 Rail XR100 Rail XR1000 Rail Internal Splices 47 4l 41 47, 47 4 4" SS 18-8 BOLT 4�.a__ 1/4" SS SERPATED FLANGE NUT ALUMINUM 18OMPH: - END CLAMP & MID CLAMP Z 30DEc s eaS SOLAR MODULE: 18.05 sq-ft DISTRIBUTED LOA 3 8 Ib ALLOWABLE LOAD• 6,010 Ibs _ „ _.. _ _. 36 s ALLOWABLE LOAD: 529 Ibs 49 49 Q „a 52 57 _ DISTRIBUTED LOAD. 363.8 Ibs I A low -profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices - _ __- Q `�' U for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. -- 5 J of$ • 6' spanning capability 8' spanning capability 12' spanning capability • Self -tapping screwsC kEM A 3/8" SS 18-8 BOLT ALUMINUM RAIL a) ca 0 Cr °' • Moderate load capability • Heavy load capability Extreme load capability • Varying versions for rails YS if J U 3/8" SS SERRATED FLANGE NUT ALLOWABLE LOAD SPAN @ 180MPH: 51" I` 3 Q • Clear &black anod. finish •Clear &black anod. finish Clear anodized finish •Grounding Straps offered "f' --DISTRIBUTED LOAD SPAN @ 180MPH: 48" 0? U) p tt1' ALLOWABLE LOAD: 11 ,930 Ibs. ALUMINUM FLASH FOOT2 lr _J CHEM LINK Brands Last Revision: 05/19/14 MAX. DISTRIBUTED LOAD: 532 Ibs ALLOWABLE LOAD: 707lbs. v a X -- attachments --'---'-- '_"`� `"""""" """' Telephone: 800-826-1681 Document No. L1274 „ � , ~ Fax. 269-679-4448 5/16 SS LAG BOLT MAX. DISTRIBUTED LOAD: 532 Ibs 353 East Lyon Street - FlashFoot Slotted L-Feet Standoffs Tilt Legs Schoolcraft,Mi49087 ;r _. 5/16" SS FENDER WASHER Product Description ' ALLOWABLE LOAD: 798 Ibs. - - - lw hgmlink. comp MAX. DISTRIBUTED LOAD: 532 Ibs -1 Marine is a moisture cure polyether sealant formulated for applications above the water low ine and in d' line or after curing solvent basedematerhals are nater lot tolerated. The product is solvent free and contains no isocyanates SEALANT ALUMINUM FLASHING SHINGLE It will not shrink upon curing will not discolor when exposed to ultra violet light, and will not out-gass' or` • in, AN i bubble on damp surfaces as urethane sealants often Ii;^ do. The sealant has resilient elastomeric properties ell and excellent adhesion to most substrates. It can co ¢�(h •: Anchor, flash, and mount Drop -in design for rapid rail Raise flush or tilted Tilt assembly to desired be used effectively in many difficult conditions, cures ? • a=,alPi ,.,i,, s,,,,, ,e+. ' i O 00 with all -in -one attachments. attachment. systems to various heights. angle up to 45 degrees. rapidly in wet re dry climates, and low temperatures N r compared to urethane based materials. Advantages ROOF DECK '� tv � P •100%VOCCompliant 3" �2X4 RAFTERS 24 O.C. r` • Ships with all hardware • High -friction serrated face • Works with vent flashing • Attaches directly to rail Tough elastomeric bonds SLOPE: 18.05 DEGREES U_ Lc) Standards and Compliance • Solvent Free a(D • IBC & IRC compliant • Heavy-duty profile shape • Ships pre -assembled • Ships with all hardware • Conforms to OTC Rule for Adhesives •Fast Setting aj u- °1 rn • Certified with XR Rails • Clear & black anod. finish • 4" and 7" Lengths • Fixed and adjustable Meets requirements d California Regulations: • High adhesion O o g 1 CARS, SCAOMD, and BAAQMD • Paintable within 24 hours Q U CO � • Conforms to California Proposition 65 • Gun grade, no special tools or mixing required LAG BOLT WITHDRAWAL LOADS (Ibs) ) C ( F 0 Bolt Tension And Shear < � Ln ; Clamps &Grounding VOC Content Less than 15 grams per liter m plied at temperatures as low as CD O U e.._...,__. ASTM D-2369, EPA Method 24 32 S„ rUCe' Pine' Fir c0 Strength Chart Lag screw speci7cations U) M End Clamps Grounding Mid Clamps T Bolt Grounding Lugs (j) Accessories Applications Substrates colors va° Stainless Steel Bolt Speci?c 5/16? shaft, wflod -- Tension strengm(ib): 6,010 per inch thread depth o to fiberglass : Teak deck planking White „ 00 Shear Stren th(lb : 5,300 ravit g ) gravity `Additional colors available by special order. Portlights Fiberglass p ,('1 _ 318" Stainless Steel Bolt " AIR Deck fittings Gelcoat Tension Strength(lb): 14,830 0.50 266 { �r ki ' Fiberglassfosnerglass Metal PackagingShear Strength(lb). 11;930 y-; .Moldings Glass 12 cartridges/carton, 105 cartons/pallet Struts and planking Polycarbonate 20 oz (600 mp available by special order * Rails, L-Foot, Mid -clamps & End -clamps are extruded using one of the following aluminum alloys: 6005-T5, 6105-T5, 6061-T6 Sources: American Wood Council, NDS 2005, Table 11.2A, 11.3.2A. _L - 12 sausages/carton, 45 cartons/pallet its Most plastics' . 5 gallon ails or 50 gallon drums �i 9 P 9 ASCE 7-10 Velocity Pressure Lag Screw Installation Guidelines Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and `rest all plastic substrates for bond strength and available by special order compatibility before application. q-10 0.00256K A i 6 d 12 ■i`I/1■ modules at ends of rails. in the middle of the rail. rail's top slot. organized look for rails. 1. Determine location for the L-Bracket on roof by ,here t he�✓ • Mill finish &black anod. •Parallel bonding T-bolt •Easy top -slot mounting =Snap -in Wire Clips iscE --mo eWctr, prei,,uree,aln:acda[mem root hei_hitpstl' drilling through the center of truss from bottom rvsxrru'rr. `. I he rtc pressure cuetlicien[ p ,el, ,resra • Sizes from 1.22" to 2.3„ p • Reusable up to 10 times • Eliminates re-di,lling • Perfected End Caps r K-i « io ahie factor with 5/32"drill bit. ARRAY WIND LOAD CALCULATIONS LAG BOLT PULL OUT CALCULATIONS ed Inddirecticm,hn factor 2. Mark mounting holes for L-Bracket on underlayment. • Optional Under Clamps • Mill & black stainless • Swivels in any direction • UV -protected polymer I - basic,c indspeed nnph, ftom atfF dU ivapsrefenrd Ina, - SOLAR PANEL 9 Spruce, Pine, per inch Thread Depth 2661bs. ul°matewfndspeedmapsin-ut tec y MountingDri l15 olepilot holes should . centered on the trusses. Total Area (SF) 162.45 SS Lag Bolt 5/16"x4" Min. Thread Depth 3" `s'i'es[irde. foran ina, hao;n m,reaof c8.04, ft_ r' r Resources _ thet taluprfengnr ultan[Iforce con onfi[earra, 4. Apply sealant to bottom of L-Bracket. Wind Load PSF -58.9 Wood Strength x Thread Depth = Pull Out Strength could be .I pst, s.04,y. ft. v I;g.;<u it, .nooinp this ( ) g p g 5. Place L-Bracket over roof underlayment resu tan[ torcr. the desi n eneinrer can nue determine lI i (i I" ,t om ' • the number of utmchmen: rots and the size of ti,e ei Total Wind Load (Ibs.)-9568.305 266lbs. x 3 in = 798Ibs. with holes in roof. mountine hardirare nrcessan to snfel) eanq this load. Design Assistant A NABCEP Certified Training Total Roof Mounts (#) 18 Allowable Pull out Strength per Lag Bolt 798Ibs. t coeds: 6. Apply sealant to bottom of L-Bracket, apply sealant to lag screws, and fasten L-Bracket securely to trusses. Go from rough layout to full Vz Earn free Continuing education credits, Tension Force per Mount (Ibs.) -531.6 Max. Pull Out Strength Required per Lag Bolt -531.6 p 7. Apply additional sealant to top assembly to be sure g Y Y9, lneloads as , iateA «i[h ho „IWic ssmn ,rc t11111171p Jr, while learning more about Our systems. Tension Force per LAG-BOLT(lbs.) 31.f Lag Bolt Pull Out Strength Safety Factor 1.5 usual, assumed toledistributed undonnl and ,re,tcoll ra, engineered system. For free. 9 Y „ ,�^� onmrorderoflpsrorlr„- all penetrations are sealed. \\�\ a,? a..:"nRid�Ai'ai.vwoRt €a yam: - p �'i 'nge f.a- i 4 // ugy a� 3�y p � \ / \.,Y6 a4,d ,PBfb .CS'u.=1inntSC S hS:S.d Ati[ Q • ry40^:, d IRONRIDGE ` FlashFoot2 ABOUTTHSTOOL: oo: This tool is based on the C&C Wind Loads for Enclosed h�P Installation Features Q�•' s ; buildings. Design wind pressures are calculated using ASCE 4•••,• �QV Fyo: The Strongest Attachment in Solar DESIGN WIND PRESSURE CALCULATIONS 7-10 equation 306-1All notes inFigures 30.4-1and 30.4- �'.� s' FOR SOLAR MODULES INSTALLED ON ROOFS 2(A.B,and C) have been incorporated Meanroofheight 'O,pROFEs '` must be less than 60 feet W gtfpq lilts iiiti Ito nRidge FlashFoot2 raises the bar in solar roof protection. The unique water seal design is both , I Lag null -out (withdrawal) eanacifies (Ibs) in typical roof lumber (A= elevated and encapsulated, delivering redundant layers ;li f3� uickly align the flashing with chalk lines to find pilot holes. of protection against water intrusion. In addition, the l 4 SITE INFORMATION -- - - twist -on Cap perfectly aligns the rail attachment with the ' FBC VERSION 2017 RISK CATEGORY I I STAINLESS STEEL Lag screw speei?cations lag bolt to maximize mechanical strength. a MEAN ROOF HEIGHT (ft) 14 ESPOSURE CATEGORY C M Speci?c 5/16?shalt, 1, Makes it easier to handle and insert under the roof shingles. LENGTH (ft) 57 ROOF SLOPE(-) 18.05 N WIDTH (ft) 46 ROOF TYPE GABLE N W W o gravity per inch thread depth I_, "" c' �PARAPET HEIGHT (ft) 0 ULTIMATE WIN DSPEED 175 mph ILj LIJ �d � ul Twist -On cap +' `i �un`y A R elp to stiffen the flashing and prevent any bending or MODULELENGTH(in) 65 NOMINAL WIND SPEED 136 mph ILfA Q c i ce 2 W Douglas Fir, Larch 0.50 266 „ FlashFoot2'sunique Cap design sumps ulalee i v crinkling during installation. Z M n � 1- Z j the lag bolt and locks into place with a simple , i ; Three -Tier water seal .. MODULE WIDTH (I n 1 39.38 K 0.85 W W twist. The Cap helps FlashFoo 2 deliver h 'r FlashF,arl ..at architecture utilizes three D U Q a 3: LL superior structural strength, by aligning ! : layers of protection. An elevated platform W Douglas Fir, South 0.46 235 narailandlagboltina concentric diverts water away, while a stack of rugged #OF MODULES IN ROW 1 KZT 1.0 d J H Re W 2 to O load path. 3 components raises the seal an entire Inch, i/J v r W (n The seal is then fully-encapuslated by the w.__.__-_ _ ......._ _._.... ...._._. 2 ly = P cap FlaehFoot2isthe first solar attachment ___ �� "" EFFECTIVE WIND AREA (ft) 18.0 KZ 0.85 LU H Engelmann Spruce, Lodgepole Pine to pass theTAS-tee wind-bdveaRain Test. LLl W CV M n H a Z (MSR 1650 f & higher) 0.46 235 ;I,' I`Illlll; a Benefits of Concentric oading Z J M = W t# nxri J K ..� r g j Traditional solar attachments have a r' DESIGN CALCULATIONS W �_ J W Hem Fir Redwood (close grain) 0.43 212 horizontal offset between the rail and lag „„ E 2 Z Ui W O r r F i bolt, which introduces leverage on the lag sa: ! iVELOCITYPRESSURE(q)= .00256*KK K V Z T I bolt and decreases uplift capacity. s i 2 2T D a W M Q l- LL J I,I '' VELOCITY PRESSURE(ASD) 33.9 Q M J ci Hem, Fir (North) 0.46 235 f FlashFoot2isthe only product toalign the 0Do W W rT,� r k rail and lag bolt. This concentric loading - V ILL J11Tead E °dill "'��° 'id='r l.,d,�Id '"`fliv '„ design results in a stronger attachment for * _ , , Southern Pine 0.55 307 depth I the system. kaia=a-;5o?rg�u.o IWIDTH OF PRESSURE COEFFICIENT 46 10% - 4.6 WIDTH 48 0 l y, ' 14' * 40°/ - 5 6' L . Spruce, Pine, Fir 0.42 205 fd, 4ah Testing Certification EXTERNAL PRESSURE COEFFICIENT ZONE 1 0.9 -0.9 Spruce, Pine, Fir ZONE 2 0.9 -1.6 DATE: 8/22/2019 (E of 2 million psi and higher "l; , „ i , I iiil tat, h'h, , ! Designed and Certified for Compliance with the International uilding Code ASC is 1-7. SCALE: NTS grades of MSR and MEL 0.50 266 g ) i ZONE3 0.9 2-4 - a o Single Socket Size Er "' ' I; `f$° 'r' Aoustom-design lag bon allows �3 :, ' you to install FlashFoot2 with I the same 7/16' socket size ' used on other Flush Mount °m. Water Sealing Tested to ILL 441 Section 27 "Rain Test" and TAS 100-95 "Wind Driven Rain Test" by intertek. Ratings applicable for composition shingle roofs having slopes between 2:12 and 12:12. UL 270 i INTERNAL PRESSURE COEFFICIENT 0.18 _ _ -_ _ _ ___ _ .r .I Sources: American Wood Council, NDS 2005, Table 19.2A, I I.3. ZA. DRAWN BY: J.B Notes: (1) Thread must be embedded in the side grain of a Trusses or other structural member integral with the building structure'. system components. , '�'•• "' Water Shedding Design Requirements. See Flush Mount Install Manual for full ratings. Conforms to UL 270 Mechanical and coding Re 9 DESIGN PRESSURES (2) Lag bolts must be located in the middle third of the structural member. An elevated plafformdivedswater away from the wafer seal. ROOF ZONE DOWN UP PAGE: (3) These values are not valid for wet service. PQ ON '� � 1n_ (4) This table does not include shear capacities. If necessary, contact a local engineer to specifiy lag bolt size aT 35.8 35.8 p S=2 with regard to shear forces. 35 8 58 9 (5) Install lag bolts with head and washer flush to surface (no gap). Do not over -torque. 3 35.8 -88.6 psf (6) Withdrawal design values for lag screw connections shall be multiplied by applicable adjustment factors if necessarv. See Table 10.3.1 in the American Wood Council NDS for Wood Construction. Location Map: Aerial View: r ' :,ct��tG.m1slk��a�:itr�M1�+;rf�d �llt�S4'rFr�Fli4 t.d„�t+��tl� n f'w Cs e+CL �rc Mi[r �aiaJ !RMII ;r r "1 r _. ...w:...,_.....:w,......w.....,,......�,..w:4................�..,..W4......,.,�.,„..,r�....:..WW...�".. �' .•���7�kG��'ei .�.......�....:,..,,,....�.,a..�..m.m.,....»-.W.,..... 'd'B;?�^�'9.1° nmWmrw- �'Pe� ��i4� neon ndex: Llk mill 11"JIFEW16 "IL US 1 �.l 5CACu i� LL L LL LL �a w CO N 00 _ O Q V M C J 7 LL O Cr LLJ (1) J C .� HJ > O a LU o d U) u; CO o va (9 COO CO CO ._ CO J LL O N LL O > Z O O c�moU W/J 00 CO r W OD ry O V yv" d 4i . 2 — ry 4 C j;. � N * Cl) M N O LU N W a LLj LLI4 mmt0 avWiQ f 6 W W M>~ LLJ C�JJW CO O NW�M^~Jf— W W N M p a Z Jz�-J2=2w w0� -J�OW Q W M Q~ LL J O D W UJ O UW� J U- DATE: 9/6/2019 SCALE: NTS DRAWN BY: J.B PAGE: C=1 H, S-ENE 305W 65.7" REVISIONS: N 0 I I r r , • I I -- —--.-.--- ----- b._------- — ROOF MOUNTS TYP Imo! SOLAR MODULE TYP. ALUMINUM tOOF MOUNTS MEASUREMENTS AC OPERATING VOLTAGE 240VOLTS AC OPERATING CURRENT=AMPS MICROINVERTERS LOCATED UNDERNEATH MODULES FOR SERVICE CALL (PV COMPANY #) LABEL FOR EACH J-BOX LABEL SIZE: 4" x 2" NOTE: INSTALLER MUST FILL IN AC OPERATING CURRENT ON LABEL. PHOTOVOLTAIC MICR• LOCATED MODULEPV ON • •. ARRAY FOR SERVICE PLEASE CALL (PV O . - PV SOLAR BREAKER DO NOT RELOCATE THIS OVERCURRENT DEVICE INSTALLED IN MDP PHOTOVOLTAIC DISCONNECTzi� AC III► NNgwelm ♦ r LABEL FOR SOLAR DISCONNECT LABEL SIZE: 4" x 2" NOTE: INSTALLER MUST FILL IN AC OPERATING CURRENT ON LABEL. F 10M WINNOW LABEL FOR SOLAR AC COMBINER BOX LABEL SIZE: 4" x 2" o CAUTION c SOLAR POINT OF CONNECTION LABEL FOR MAIN DISTRIBUTION PANEL LABEL SIZE: 4" x 1" WARNING 0 DUAL POWER SUPPLY SOURCES: UTILITY AND PV SOLAR ELECTRIC SYTEM LABEL FOR MAIN DISCONNECT OR METER LABEL SIZE: 4" x 2" �" 4 s It I % • NEC 690.12 LABEL FOR SOLAR DISCONNECT LABEL SIZE: 4" x 2" NOTE FOR ALL LABELS: LABELS SHALL BE UV RESISTANTAND SHALL HAVE WHITE LETTERS ON A RED BACKGROUND. 2FT OFFSET I 39.34" ALLOWABLE Load: (5400Pa) 113 psf NOTE: Install mid clamps between modules and end clamps c at the end of each row of modules. NOTE: ALUMINUM RAILS SHOULD ALWAYS BE SUPPORTED BY MORE THAN ONE FOOTING ON BOTH SIDES OF THE SPLICE." ROOF AREA EXISTING SHINGLE ROOF TOTAL ROOF AREA: 3,574 sq.-ft TOTAL PHOTOVOLTAIC AREA: 774 sq.-ft PERIMETER WIDTH: 4.3' PRESSURE ZONE: 1 & 2 MEAN ROOF HEIGHT: 14' ROOF SLOPE: 3:12 TOTAL MODULES: 32 MIN. ROOF MOUNTS: 64 TOTAL POINT OF CONNECTIONS PER MODULE: 4 ALUMINUM RAILS: 2 SOLAR ELEC. PANEL & DISC. ROOF PLAN m aS o0 > rn Q I— comJ O c Z3LL Q 0 S aj _J _I (6 U I— J 2i W a) LU s U) U) a M p CO V� (0 M O N 00 V CV) LL 0)> U CID L N �moU COCo 00 V L `/ Do 0 V) 042 � ti„• S M M N O N W W LLI*W zt to a(nQ;CDV =U f 6 Z M^�~ W LU W ti Z =)V W acccn�iLL aJF-4002w0 W W N M L O a. z tn=J~OUW �QQ00 ��W WLL� 0 _ LL I DATE: 9/6/2019 I SCALE: NTS DRAWN BY: J.B PAGE: smi REVISIONS: T os Aerial View: Ma\\q C�o� oc�q e ° i El ELECTRICAL Sl E. STRUCTURAL DIAGRAMS S2'1. STRUCTURAL CALCULAFIONS ,. B o � W i H W c W U v �u J n % � ttt llll 0 l Q qT J C 7 W [Y S N O > J f6 U O J U W _�; o a Un U) M � O N 00 (e ti •- co J LLf) N LL 0) > c 0 CD L � cOmoL) BUJ 00 r 00 ry 0 V ! '41:2 N O.6"W i� M M N O Lu N W CD uj*W N�cD n fnQMcp�2 W cli z > ~ Z W a� ?UWQIu. f1J�_4000 =w Fn W i j� X J H W W NchoF-0.Z JZ�_j 21 W53:LL UW ZLI.ILu>- a Q M a H J O W LL U O J U. DATE: 9/6/2019 SCALE: NTS DRAWN BY: J.B PAGE: cmi MOUNT LAYOUT L I I 1 I i i t � I I I i I I I i I I T I I C I I I I I I I • I I • I i -1------- ------- _ --------- a ROOT MOUNTS TYP. - I I I " I �- SOLAR MODULE TYP. I I I I I I ALUMINUM ROOF MOUNTS MEASUREMENTS PHOTOVOLTAIC POWER SOURCE AC OPERATING VOLTAGE 240VOLTS AC OPERATING CURREN r�]AMPS MICROINVERTERS LOCATED UNDERNEATH MODULES FOR SERVICE CALL (PV COMPANY #) LABEL FOR EACH J-BOX LABEL SIZE: 4" x 2" NOTE: INSTALLER MUST FILL IN AC OPERATING CURRENT ON LABEL. PV SOLAR BREAKER DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL FOR SOLAR CIRCUIT BREAKER INSTALLED IN MDP LABEL SIZE: 2" x 1 PHOTOVOLTAICAC DISCONNECT AC OPERATING VOLTAGEVOLTS AC OPERATING CURRENIAMPS LABEL FOR SOLAR DISCONNECT LABEL SIZE: 4" x 2" NOTE: INSTALLER MUST FILL IN AC OPERATING CURRENT ON LABEL. A• • '10i " LABEL FOR SOLAR AC COMBINER BOX LABEL SIZE: 4" x 2" At CAUTION o SOLAR POINT OF CONNECTION LABEL FOR MAIN DISTRIBUTION PANEL LABEL SIZE: 4" x 1" DUAL POWER SUPPLY SOURCES:AND SOLARPV - LABEL FOR MAIN DISCONNECT OR METER LABEL SIZE: 4" x 2" NEC 690-12 LABEL- SOLAR DISCONNECT LABEL NOTE FOR ALL LABELS: LABELS SHALL BE UV RESISTANT AND SHALL HAVE WHITE LETTER:+ ON A RED BACKGROUND. SHARPIE EXTREME OR EQUIVALENT UV RESISTANT MARKERS SHALL BE USED FOR WRITING ON LABELS REQUIRING INSTALLER -WRITTEN VALUES. 2FT OFFSET S-ENER J 305W 65.7" ALLOWABLE Load: (5400Pa) 113 psf 39.34'L_� NOTE: Install mid clamps between modules and end clamps AD nnnnl 11 1= at the end of each row of modules. NOTE: ALUMINUM RAILS SHOULD AL«'AYS BE SUPPORTED BY MORE THAN ONE FOOTING ON BOTH SIDES OF THE SPLICE." ROOF AREA EXISTING SHINGLE ROOF TOTAL ROOF AREA: 3,574 sq.-ft TOTAL PHOTOVOLTAIC AREA: 774 sq.-ft PERIMETER WIDTH: 4.3' PRESSURE ZONE: 1 & 2 MEAN ROOF HEIGHT. 14' ROOF SLOPE: 3:12 TOTAL MODULES: 32 MIN. ROOF MOUNTS: 64 TOTAL POINT OF CONNECTIONS PER MODULE: 4 ALUMINUM RAILS: 2 SOLAR ELEC. PANEL & DISC. ROOF PLAN M Q c co - J J I— W U a) J LU I_ U) s 0 viU) CO p } 'Z d C� o� N qt N M `= co J LO N LL M > U cflm00 UJ 00 co M `. op 00 LMLS w i� * _ F. O vl �i wC M M N O N H W �j � W . 0 to W W M ti>~ z :DvWav LL CiJI-400=WU) �W1--M^~JH WWNM0�_az W03 _JFOW aWMa''��� 200,02 x5LL, W LL 0 _ LL DATE: 9/6/2019 SCALE: NTS �]1XIIII .L I'A" fl PAGE: S=1