Loading...
HomeMy WebLinkAboutPRODUCT EVALUATION REPORTForce Enginecring & Testing Inc. 19530 Pa blood Drive Humble,TX 77338 Product Evaluation Report CARPORTS ANYWHERE Hampton Rib Wall Panel over open framing Florida Product Approval # 27403.1 Florida Building Code 2017 Per Rule 61G20-3 Method: 2-8 Category: Structural Components Subcategory: Structural Wall Compliance Method: 61G20-3.005(2)(b) NON HVHZ Product Manufacturer: Carport Anywhere 10858 S.E. County Road 221 Starke, Florida 32091 Engineer Evaluator: Terrence E. Wolfe, P.E. # 44923 Florida Evaluation ANE ID: 1920 Validator: Gary Hartman, P.E. #73227 Contents - Evaluation Report Pages 1-4 SCANNED BY. QW11.Lucie County ``E!,F, rfYr�r', � 'fit C E F4NO i° • STATE OF : q se.mrbm, S •. 1 FIAT 27403.1 JI 41 & 18, 2018 Force Engineering & Testing Inc. 19530 Ramble od DA. HumblgTX 77339 Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1709.2. Product Description: Hampton Rib 26 Ga. and 29 Ga. Steel Wall Panel, 36' Wide, through fastened structural wall panel. Structural Application. Panel Material/Standards: Material: 26 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 50 29 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 80 Conforming to Florida Building Code 2017 Section 1405.2. Panel Dimension(s): Thickness: 26 Ga.: 0.0185" min. order thickness 29 Ga.: 0.0142" min. order thickness Width: 36" maximum coverage Rib Height: VV major rib at 9" O.C. Panel Rollformer: MRS Metal Rollforming Systems Panel Fastener: #12-14 x Y." HWH SD#3 with 14mm neoprene bonded washing or approved equal. Corrosion Resistance: Per Florida Building Code 2017. Substrate Description: Minimum 14 Ga. (Grade SO) Steel framing, Minimum 16 Ga. (Grade 50) Steel framing, or Minimum 18 Ga. (Grade 50) Steel framing. See Table A & B for steel gauge. Framing must be designed in accordance w/ Florida Building Code 2017. Allowable Design Pressures: Table 'A' 26 Ga. Nameten Rib Wall Paunl Maximum Design Pressure: -57.3 psf .72.9 psf -67.7 psf a46.9 psf ♦54.7 psf Panel Fastener Pattern: 2-1-2-1 2-1-2-1 2-1-2-1 2.1.2.1 2-1-2-1 Panel Span: 51-V O.c 4'-0' O.C. 4'-0' O.C. 51-0' O.C. 4'-0' O.C. Substrate: MN. 14 Ga. Steel Framing Min. 14 Ga. Steel Framing Min. 14 Ga. Steel Framing Min. 18 Ga. Steel Framing Min. IS Ga. Steel Framing Design Pressure Includes a Safety Factor - 2.0. FL# 27403.1 aaaaaal 111111 rII�� ,�aa�E M C E, E h,O r•�• A4,q- CENSF <,o• v A' STATEOF F tm•• QUA. W6 I� S 1 03 011" O N i *- %\ JU41,.IS, 2018 Force Engineering & Testing Inc. 19530 Ramblewood Drive HumblgTX 77338 Table "Re 79 re Maximum Design Pressure: -573 psf -1509 psf +39.0 psf +143.1-p5f Fastener Pattern: 6'-3"-6'-3"•6"-3"-fi'1 6'-3--V.3" "-3--6" 6'-3'-6 -3--6'-3'{' Fastener spacing: 4'-0"D.C. r-0"O.C. 4'-0"-0.r 2'-0'O.C. oogn rressum mauaes a sarery racior= z.u. Code Compliance: The product described herein has demonstrated compliance with The Florida Building Code 2017, Section 1709.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61G20-3. Performance Standards: The product described herein has demonstrated compliance with: • ASTM E 1592-05 (2012) Test method for structural performance of sheet metal roof and siding systems by uniform static air pressure difference ' Reference Data: 1. ASTM E 1592-05 (2012) Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 667-0060T-18A-E, 667-0061T-18A-D 2. Certificate of Independence By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc. (FBC Organization # ANE ID: 1920) Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Installation: Install per manufacturers recommended details. Insulation: Manufacturer's approved product (Optional) Panel Fire Classification: Fire classification is not part of this acceptance. amarmu ens •YRi FL# 27403.1 aaaaaa It, 1111 "r l CE ttSe;�• ORAL rt 111 N Ji tvw 18, 2.018 Force Engineering & Testing Inc. 19530 Jtamble ad Drive Humble,TX 77338 Shear Diaphragm: Shear diaphragm values are outside the scope of this report. Design Procedure: _ _ _ __.Based on the.dimensions of the structure, appropriate wind loads are- - — — - — - — - -- determined using Chapter 16 of the Florida Building Code 2017 for wall cladding wind loads. These component wind loads for wall cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and. pullover. Support framing must be In compliance with Florida Building Code 2017 Chapter 22 for steel, and Chapter 16 for structural loading. ' V `••% V'L No. 449 vJ) STATE OF a: 'rrro �in3� J,, FL# 27403.1 jMh%t'sa, zoos 26 GA. HAMPTON RIB FASTENER PATTERN 2-1-2-1 `R12-14 v 3/4' WNH S03 W/ 14MM BONDED NEOPRENE WASHER 29 GA. HAMPTON RIB FASTENER PATTERN 6"-3"-6 3"-6"-3"-6" 6. 3' 6- 3'—.— 6- _ . - 3 - . - 6' 3. #12-14 [ 3/4" HWH S03 W/ 14MM BONDED NEOPRENE WASHER %ft o4 podd9 CAA glam No.44923 STATM 04 10182618 FL# 27402.1 R1 �y Force ErigIncering & Testing Inc. 19530 R mbl.od Ddv. HumbIgTX77338 Product Evaluation Report CARPORTS ANYWHERE Hampton Rib Roof Panel over open froming Florida Product Approval # 27402.1111 Florida Building Code 2017 Per Rule 61G20-3 Method: 1—D Category: Structural Components Subcategory: Roof Deck Compliance Method: 61G20.3.005(1)(d) NON HVH2 Product Manufacturer: Carport Anywhere 20858 S.E. County Road 221 Starke, Florida 32091 Engineer Evaluator: Terrence E. Wolfe, P.E. # 44923 Florida Evaluation ANE ID: 1920 Validator: Brian Jaks, P.E. #70159 Contents: Evaluation Report Pages 1-4 SCANNED BY St.Lucia County J @ • !vo O n �Q�Vt cE JfSF�� JQ� *� C STATE OF ; it oN tttt>'`tttt August 8, 2019 Force Engineering & Testing Inc. 19530 Ramblesvood Drive Humblc,TX 7733E Compliance Statement: The product as described In this report has demonstrated compliance with the Florida Building Cade 2017, Sections 1504.3.2, 1504.7. Product Description: Hampton Rib 25 Ga. and 29 Ga. Steel Roof Panel, 36" Wide, through fastened structural roof panel. Structural Application. Panel Material/Standards: Material: 26 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 50 29 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 80 Conforming to Florida Building Code 2017 Section 1507.4.3. Optional paint finish. Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507.4.3. Panel Dimension(s): Thickness: 26 Ga.: 0.0185" min. order thickness 29 Ga.: 0.0142" min. order thickness Width: 36" maximum coverage Rib Height: Y." major rib at 9" D.C.- Panel Rollformer: MRS Metal Rollforming Systems Panel Fastener: 912-14 x Y.." HWH SDp3 with 14mm neoprene bonded washing or approved equal. Corrosion Resistance: Per Florida Building Code 2017, Section 1507.4.4. Substrate Description: Minimum 14 Ga. (Grade 50) Steel framing, Minimum 16 Ga. (Grade 50) Steel framing, or Minimum 18 Ga. (Grade 50) Steel framing. See Table A & B for steel gauge. Framing must be designed in accordance w/ Florida Building Code 2017. Allowable Design Pressures: Table "A" 26 Ga- Hamvtnn Rib Renf Pan"I Maximum Design Pressure: -57.3 psf -72.9 psf -673 psf -46.9 psf ♦54.7 psf Panel Fastener Pattern: 2-1-2-1 2-1-2-1 2-1-2.1 2-1-2-1 2-1-2.1 Panel Span: 5'-0. O.C. 4'-T O.C. 4'-0" O.C. 5'-0" O.C. 4'-0. O.C. Substrate: Rn.14Ga. Steel Frdming Min. 14 Ga. Steel Framing Min. 18 Ga. Steel Framing Min. 18 Ga. Steel Framing Min. 18 Ga. Steel Fmming Design Pressure Includes a Safety Factor= 2.0. FL# 27402.1 RI August 8, 2019 Ponce Engineeriring & Testing Inc. 195J0 Rambicw99d Ddve Humbic,T7t 77338 Table "8" 79 na. Namntnn Maximum Design Pressure: - -573 psf -150.9 psf 39.0 psf +143.1 psi Fastener Pattern: 6"-3"-6•-3"-6•-3•-6• 6"-3•-6•-3•-6.3•-6• 6+ 3•{^-3•-6"-3={• 6�3•-6•-3•-6 -3•{• FastenerSpacing: 4'-0"O.C. 2'-0. O.0 4'-0"O.C. 2'-0"O.C. Substrate: Min. 16 Ga. Steel Framing Min. 16 Ga. Steel Framing Min. 16 Ga. Steel Framing Min. 16 Ga. Steel Framing -Design Pressure Induces a Safety Factor = 2.0. Code Compliance: The product described herein has demonstrated compliance with The Florida Building code 2017, Section 1SO4.3.2, 1504.7. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61G20-3. Performance Standards: The product described herein has demonstrated compliance with: • ASTM E 1592-05 (2012) Test method for structural performance of sheet metal roof and siding systems by uniform static air pressure difference • FM 4471-92- Foot Traffic Resistance Test Reference Data: 1. ASTM E 1592-05 (2012) Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 667-0060T-18A-E, 667-0061T-18A-D 2. FM 4471-10, Section 4.4 Foot Traffic Resistance Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 667-006OT-18F, 667-0061T-18E 3. Certificate of Independence By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc. (FBC Organization # ANE ID: 1920) Test Standard Equivalency: The FM 4471-10, Foot Traffic Resistance test standard is equivalent to FM 4471-92. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for ttttp S1tt1itrtt,' N G E. E ?�Vt CENSF,<�+ �NO. 41* / (� STATE OF ; e _ i�0;7 AtO It. ID=�.�44 MIMI FL# 27402.1 RI August 8, 2019 Force Engineering&Testing Inc. 19530 Rombl.00d Drive Humb],TX 77338 manufacturing under quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slopeshallcomply with Florida Building Code 2017, Including Section SS07.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per manufacturer's recommended details. Insulation: Manufacturers approved product (Optional) Roof Panel Fire Classification: Fire classification Is not part of this acceptance. Shear Diaphragm: Shear diaphragm values are outside the scope of this report. Design Procedure: Based an the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2017 for roof cladding wind loads. These component wind loads for roof cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2017 Chapter 22 for steel, and Chapter 16 for structural loading. FL# 27402.1 RI t H 'Z. r C. EI Q H cE � C; • `, 1 S August 8, 2019 1 >' 26 GA. HAMPTON RIB FASTENER PATTERN 2-1-2-1 `#12-14 . 3/1' ITNII SDJ VI/ MpA BONDED NEOPRENE WASHER 29 GA. HAMPTON RIB FASTENER PATTERN 6"-3"-6"-3"-6"-3"-6" 6- _ 3-_ . _ 6 3- 0. 3 6. 3' ` a12-14 x 3/4' 14VH SUS Vl/ 14MM BONDED NEOPRENE WASHER 8181001FIOdd9 O.OA. 928710 No.44923 d+rr STATE OF August 8, 2019