HomeMy WebLinkAboutGENERATOR INSTRUCTION16/20/22 kW
INCLUDES:
• True Power'" Electrical Technology
• Two Line LCD Multilingual Digital
Evolution'm Controller (English/Spanish/
French/Portuguese)
• Two Transfer Switch Options Available:
100 Amp, 16 Circuit Switch or
200 Amp Service Rated Smart Switch.
See Page 4 for Details.
• Electronic Governor
GENERAC®
ST.LUCIE COUNTY
PLAN REVIEW
BLDG:
GUARDIAN® SERIES
DATE.
Residential Standby Generators
EL .
i
Air -Cooled Gas Engine
DATE:
PLUMB:
MECH: Standby Power Rating
DA'lldpdels G007036-0, G007037-0 (Aluminum - Bisque) - 16 kW 60 Hz
Model G007035-0 (Aluminum - Bisque) - 16 kW 60 Hz
Models G007039-0, G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz
Models G007043-0, G007042-0 (Aluminum - Bisque) - 22 kW 60 Hz
MAI(�NED
St L-W&CM1741
• System Status & Maintenance Interval LED Indicators
• Sound Attenuated Enclosure
• Flexible Fuel Line Connector
• Direct -To -Dirt Composite Mounting Pad
• Natural Gas or LP Gas Operation
• 5 Year Limited Warranty
• Capability to be installed within 18" (457 mm)
of a building*
FEATURES
O INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of
GENERAC'S success in "IMPROVING POWER BY DESIGN." But it doesn't
stop there. Total commitment to component testing, reliability testing,
environmental testing, destruction and life testing, plus testing to applicable
CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC
POWER SYSTEMS with the confidence that these systems will provide superior
performance.
O TRUE POWER" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave
form produce less than 5%Total Harmonic Distortion for utility quality power. This allows
confident operation of sensitive electronic equipment and micro -chip based appliances,
such as variable speed HVAC systems.
O TEST CRITERIA:
• PROTOTYPE TESTED v NEMA MG1.22 EVALUATION
• SYSTEM TORSIONAL TESTED v MOTOR STARTING ABILITY
GENERAC`
G&Us QUIEf-FES-T-
LISTED
Note: CUL certification only applies to unbundled units and units packaged with limited circuit
switches. Units packaged with the Smart Switch are UL cerrifed in the USA only.
-Only if located away from doors, windows and fresh air intakes, and unless other-
wise directed by local codes.
O SOUDSTATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. Thisstate-
of-the-art power maximizing regulation system is standard on all Generac models. It
provides optimized FAST RESPONSE to changing load conditions and MAXIMUM
MOTOR STARTING CAPABILITY by electronically torque -matching the surge
loads to the engine. Digital voltage regulation at ±1%.
O SINGLE SOURCE SERVICE RESPONSE from Geneac's extensive dealer network
provides parts and service know-how for the entire unit, from the engine to the
smallest electronic component
O GENERAC TRANSFER SWITCHES. Long lifeand reliabilityare synonymous
with GENERAC POWER SYSTEMS. One reason for this confidence is that the
GENERAC product line includes its own transfer systems and controls for total
system compatibility.
FILE COPY
Lu GENERAC
* * Mobile n
PROMISE `•�DYEPr'�p �9HflPH, LIIII( I
-B.'a N NeU u ,p Oomrshandl ;,' .
GENERAC°
16/20/22 kW
features and benefits
Engine
•Generac (OHVI) design
Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings
helps the engine run cooler, reducing ail consumption resulting in longer engine life.
• Quiet Test"
Greatly reduces sound output and fuel consumption during bi-weekly exercise.
•"Spiny-lok" cast iron cylinder walls
Rigid construction and added durability provide long engine life.
-Electronic ignition/spark advance
These features combine to assure smooth, quick starting every time.
-Full pressure lubrication system
Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life.
Now featuring up to a 2 year/200 hour ail change interval.
-Low oil pressure shutdown system
Shutdown protection prevents catastrophic engine damage due to low oil.
-High temperature shutdown
Prevents damage due to overheating.
Generator
-Revolving field
Allows fora smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
-Skewed stator
Produces a smooth output waveform for compatibility with electronic equipment.
-Displaced phase excitation
Maximizes motor starting capability.
-Automatic voltage regulation
Regulates the output voltage to ±1 % prevents damaging voltage spikes.
• UL 2200 listed
For your safety.
Transfer Switch
• Fully automatic
Transfers your vital electrical loads to the energized source of power.
-Remote mounting
Mounts near your existing distribution panel for simple, low-cost installation.
• NEMA 3R
Can be installed inside or outside for maximum flexibility.
Evolution" Controls
-Auto/Manual/Off illuminated buttons
Selects the operating mode and provides easy, at -a -glance status indication in any condition.
•Two-line LCD multilingual display
Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences.
-Sealed, raised buttons
Smooth, weather -resistant user interface for programming and operations.
-Utility voltage sensing
Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage.
-Generator voltage sensing
Constantly monitors generator voltage to ensure the cleanest power delivered to the home.
• Utility interrupt delay
Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5
seconds by a qualified dealer.
-Engine warm-up
Ensures engine is ready to assume the load, selpoint approximately 5 seconds.
-Engine cool -down
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
• Programmable exerciser
Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5
minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and
potentially lower fuel costs to the owner.
-Smart battery charger
Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM -style batteries.
-Electronic governor
Maintains constant 60 Hz frequency.
Unit
-SAE weather protective enclosure
Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up
to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance
items. Electrostatically applied textured epoxy paint for added durability.
• Enclosed critical grade muffler
Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
-Small, compact, attractive
Makes for an easy, eye appealing installation, as close as 18" away from a building.
Installation System
• 1 ft (305 mm) flexible fuel line connector
Absorbs any generator vibration when connected to rigid pipe.
• Direct-lo-dirt composite mounting pad
Complex lattice design prevents settling or sinking of the generator system.
• Integral sediment trap
Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life.
16/20/22 kW
GENERAC`
specifications
Generator
Model
6007035.0, G007036-0,
G007038.0, 0007039-0
0007042-0, G007043-0
G007037-0 (16 kW)
(20 kW)
(22 kW)
Rated Maximum Continuous Power Capacity (LP)
_ 16,000 Watts'_
20,000 Wa6*
_ 22,000 Wafts'
Rated Maximum Continuous Power Capacity (NG)
16,660 Watts-
18,000 Watts-
19,500 Wags-
RatedVoltag_ - _ - - - -
- -240
- --_
240
- __ - 0
24e_
Rated Maximum Continuous Load Current -240 Volts (LP/NG)
66.6/66.6
83.3/75
91.6/81.3
_ _
Tota Harmonic Distortion _ _ _
_
Less than 5%
_
Less than 5%_
_
Less than 5%
Main LI_ne Circuit Breaker
70 Amp
100 Amp
100 Amp_
Phase —_ --. -- . _ _ __ __ - - - _ _ .__ _
- 1
1
1
Number of Rotor Poles
-Hated
_
2
_ _ _
2
_ _ _
- 2 '_
_ _
AC Frequency , _ _ _ _
- --
_ _ _
60 Hz _.. ' - _
__ -1.0
_ _ _ _
. 60 Hi -
- -tA-
_ - _
_- - Hi
Power Factor
_-6D
1.0-
_ . _ _
6attery,Requlrement (no[included) _-' _ _ _
_
-' 12 VO is, Group 26R 540 CCA Mi_n mu_m or G_ r_o_up 35AGN
_. _. .
- CCA_Mi_ni_mum _
Unit Weight(Ib/kg)
409/186
44g/203
466/211
_ _ _ _ _
Dimensions(L. WxH)_iymm_- _-- __ _
_
48x25x29/1218x638x732,_
Sound output in dB(A) at 23 it (7 m) with generator operating at normal load"
66
65
67
.__ _._ .__ _ __..._.._...___-__ _. _.
Sound output in dB(A) at 23 it (7 m) with generator in Quiet -Test- law -speed
_ _ __.__. _ _.
58
_ . __. __.
58
__.. _ __._... _.
58 '
exercise mode"
Fxemise duration
5 min
5 min
5 min
Engine
' Type of Engine. _ -__ _ . _ _ �_. _ � � 4 _
_ � 6ENEHAC OHV_I VPMN_ _
_ _GENEH_AC OH_VI VN_JIN _�
� �- 6ENEHAC_OtiVl V-T4YIN___ j
Number of Cylinders
2
2
2
Displacement-
999 cc
_ _ _
999 cc
_ _
� 998 cc �
Cylinder Block
w7 Cast Iron Sleeve__
_ __ _ ___ __ _
'Valve Agangemenl__ -,_ _ �� �����
_ _
Overhead Valve -- -
_ _A_lu_m_inum
Overhead Valve
Overhead Valye
Ignition System
Solid-state w/ Magneto
Solid-state W/ Magneto
Solid-state ray Magneto
_
, Governor Syatem, _, � -
_
-Electronic �
Electronic
Electronic -
Compression Ratio
9.5:1
9.5:1
9.5:1
12-Vdc
._.._ .-12 Vdc ---
- - - -12 Vdc -
0il Capacity Including Filter
Approx. 1.9 gV1.8 L
Apfamx. l.9 gV1.8 L _
Approx. 1.9 gV1.8 L _
- _
___3,600
Fuel Consumption
Natural Gas ga/hr (m3/hr)
1/2 load
193 (5.47)
205 (5.8)
184 (5.21)
Full Load
312 (8.83)
308 (8.72)
281 (7.96)
Liquid Propane ft3/hr (gal/hr) [I/hr]
1/2 Load
69 (1.9) [7.2]
81 (2.23) [8.45]
78 (2.16) [8.16]
Full Load,__
116 (3_19) [12.071
(3.85) [14.57]�
134 (3.68) [13.94]
_._ _ _-_ - -- _ .----, _- _140
i Note: Fuel pipe must be sized for lull load. Required fuel pressure to generator fuel inlet at all load ranges 3.5-71 water column (7-13 tam mercury) for natural gas 10 12 water column (19-22 tam _
'mercury)for,LP gas For Btu content muitiplytl3/hrx 2500(0)orfl3/hr x 1000 ING). For Megajoplecontenl mulllply_ma/hrx 9315(LP)prma/hrx 37.261NG)_-_
-_- __". ______ __1
Controls
12_Line Plain TeM Multilingual LCD-Oi_splzy___ _ _ _ _
-_ __. .__. _Si_mple user Interface for ease of opeafon.____
Mode Buttons:_ Auto
Automatic Start on Utility failure.7 day exerciser.
- _
Manua(_ __ _
_ _ -_
Start with starter control, unit stays on_ If utility fads, transfer to load takes place_
_ _
0g
_ _ _ _ _ _
Stops unit. Power is removed. Control and charger still operate.
Standard
Engine Run Hours
SlandaN
_d_lation
Programmahle;lad delay be2-1500 seconds
_ SWndartl(programmable bydealeronly)_____
Utility Voltage LosOeturn to Utility Adjustable (Brownout Setting)
From 140-171 Wl90-216V
Future Set Capahle Exerciser/Eeerclse Set Error Waning
_
_ _ _ _
AuNAla mNaintenance logs
_ _ _ _Standard__
50 Events Each
',Engine Start Sequence __. -__
___
-_, _ Cyclic canting 16see on, 7rest (90 sec maximum duration).
Starter Lock-om
_,_ _-
Slader cannot re-engage until 5 sec after engine has stopped.
__
Smart Bagery Charge
_
_ _. _ _._._Standard_
LOW, Battery/Bagery_Prahlem Pmtectiod and Battery Cariditlon lndlcation
�'� Standard
Automatic Voltage Regulation with Over and Under Voltage Protection
Standard
Under-Frequenq/Ovedoad/Stepper Ouercurre_n_t P_rolec_[io_n_ _ _ -., _
_ _ _ _ _ Standard
Safely Fused/Fuse Problem Protection
Standard
_-__-.___ —._
Aulpmaliclnw Oil PressureMlgh Oil Turn undone Shutdown ,- _ _,. _ - _ --- - ---
-
_ _ ___ __ _ ___
-, _ - Standard _ _-. _ -_
_ - - �Standard
OvercumWOverspeed ((@ 72 Hz)/rpm Sense Loss Shutdown
_ _
High Engine Tempeature Shuldowq
_
Internal FaultAncorrect Wiring Protection
---Standard
Standard
Common Eatemal Fault Capability _
Standard
Fluid Upgradable Homage
Standard
-Sound 1welsare taken from the had olthe generator. Sound levels loan from other sides of me generator maybe higher depending on insWhdw coronaries. Rating dehninom-Seenuby: Applicable for supplying emergency punier forme duration
eltleufilih eoutage. NoovekadcapabiliyisauailableformisaWg (All ratingsln acwnfanceath BS5514, IS03046 and D146271). •Maimum urage and curtail are subject to and limited by surd news a fuel BWmegajoule wnten(
amblemlempealuM al ilude, engine paver and wndiu'on, etc Ma4mum poserdeueasesabom 15 percemfor earl 1.000 feel (304.8 meters) above sea level; and dsavin dewase about perrourtfor each 6 `C (10'M above 16 Z (60'M.
GENERAC•
16/20/22 kW switch options
Limited Circuit Switch
• 16 circuits.
Electrically operated, mechanically -held contacts for fast, positive connections.
Rated for all classes of load,100% equipment rated, both inductive and resistive.
• 2 pole, 250 VAC contactors.
• 30 millisecond transfer time.
• Dual coil design.
• Rated for both copper and aluminum conductors.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA 311 aluminum outdoor enclosure allows for indoor or outdoor mounting
flexibility.
• Multi listed for use with 1" standard, tandem, GFCI and AFCI breakers from
Siemens, Murray, Eaton and Square D for the most flexible and cost effective install.
Model
G007036-0 (15 kwt
____. ______..__
—__ ._ -__ .
Current Rating (Amps)_ _- _ _ -_ _
_ _ 10o
Voltage luting (VAC)__ -__
120/240,:10 : - _ 1
Utility Voltage Monitor (Fixed)'
-Pick-up
80%
-Dropout
65%
_app_ioix_15
Exercise bi-weekly for 12 minutes"
Standard
___—_ _
Utal
of
Total of Pre -wired Circuits
16
No. 15A 120V
5
No. 20 A 120 V
5
No. 20A 240V
1
No. 30A 240V
-
No. 40 A 240 V
1
No. 50 A 240 V
1
'Tandem Breaker Capability
_ _. .._._..
'8 spaces
Circuit Breaker Protected
Available RMS Symmetrical
Fault current @ 250 Volts
10,000
*Function of Evolution Controller
Exercise can be set to weekly or monthly
Dimensions 200 Amps 120/240, 1e
Open Tam ition Service Rated
Height Width Depth -
H1 112 f W2
7.24 IQ 230.0 11.4 13.5 7.09
mm 692.0 762.4 1 289.0 343.0 180.0
Wire Ranges
Conductor Lug Neutral Lug I Ground Lug
210-#14 210-#14 2/0-#14
Service Rated Smart Switch Features
6007037.0 (16 kw4/G007039-0 (20 kM/
• Includes Digital Power Management Technology standard (DPM).
Model
0007043-0 (22 k"
• Intelligently manages up to four air conditioner loads with no
additional hardware.
Cunent flating(Amps)
200
,Voltage Rating,(VAC)�_ -,�.
1201240 19_
• Up to four more large (240 VAC loads can be managed when used In
9
Utility Voltage Monitor (Fixed)'
conjunction with Smart Management Modules (SMMs).
-Pick-up
80%
• Electrically operated, mechanically -held contacts for fast, clean
-Dropout
65%
connections.
�eturn to Ulf liry_''-V
_
eppmx. l_3 sec,_
• Rated for all classes of load,100% equipment rated, both inductive and
Exercise weekly for 12 minutes__ _
standard
resistive.
iUL Listed
Enclosure Type_
_
• Up to four more large If 20/240 VAC) loads can be managed when used in iwidistan_d @acing (Amps] `
_ _NEMANL3R�_
—__ 220b0 —_`_—_ -___'—
conjunction with 50 amp Power Management Modules (PMM••).
_
Lug Range
250 MGM - #6
• 2 pole, 250 VAC contactors.
'Functron of Evolution Controller
• Service equipment rated, dual coil design.
• Rated for both aluminum and copper conductors.
• NEMA 311 aluminum outdoor enclosure allows for indoor or outdoor
mounting flexibility.
• Main contacts are silver plated or silver alloy to resist welding and
sticking.
Dimensions
200 Amps
0 an Transition
120/24D, 1e
Service Rated
Height
Width
Depth
H1
H2
W7
W2
in
2Z24
30.0
11.4
13.5
7.09
mm
692.0
762.41
289.0
343.0
100.0
16/20/22 kW
GENERAC"
available accessories
Model#__ Product
Description j
Generac's Mobile Link allows you to check the status of your generator from anywhere that you have
G006463-3 Mobile Link-
' access to an Internet connection from a PC or any smart device. You will even be notified via e-mail
or text message when a change in the generator's status occurs. Available in the U.S. only.
G005819-0 26R Wet Cell Battery
Every standby generator requires a battery to start the system. Generac offers the recommended 26R
wet cell battery for use with all air-cooled standby product (excluding PowerPact@).
G007101-0 Battery Pad Warmer
The pad warmer rests under the battery. Recommended for use if the temperature regularly falls
below 0°F. (Not necessary for use with AGM -style batteries).
G007102-0 Oil Warmer
Oil warmer slips directly over the oil filler. Recommended for use if the temperature regularly
below 0°F.
- - - - -
G007103.0 Breather Warmer
-falls
--- - -- - --- - ---- -— - -- - -
The breather warmer is for use in extreme cold weather applications. For use with Evolution
controllers only in climates where heavy icing occurs.
Auxiliary Transfer Switch Contact I The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical
G005621-0 I
Kit
f{-
load you may not need. Not compatible with 50 amp pre -wired switches. i
I
Fascia Base Wrap Kit
f G007027-0-Bis
:The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers
ue
q (Standard on 22 kW)
3 a sleek, cordoured appearance as well as offerinH Protection from rodents and insects by covering the
g ng holes located in the base.
_
t -
_
If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect I
G005703.0- Bisque I Paint Kit
from future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a I
G006485-0 -16. 20 &
generator enclosure. f
I
Scheduled Maintenance Kit
22 kW I
scheduled maintenance kits provide all the hardware necessary to perform complete
routine f
I routine maintenance on a Generac automatic standby
generator.
Smart Management Module
I Smart Management Modules are used in conjunction with the Automatic Transfer Switch to ;
.
G006873-0 I
(50 Amps)
Increase its power management capabilities. It provides additional power management flexibility!
i not found in any other power management system.- '
_—
— ---g — -
dimensions & LIM
Oimenslonsshownareanuudmate. Refer to Installation manual for exact dimensions DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES,
L SIQEMEW
FRMTWEN/
Model
UPC
G007035-0
696471070354
G007036-0
696471070361
G007037-0
696471070378
G007038-0
696471070385
G007039-0
696471070392
G007040-0
696471070408
G007042-0
6964710710422
G007043-0
696471070439
GENERAC' Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com
"-'�- 02016 Generac Power Systems, Inc. An rights reserved. An specifications are subject to change without notice. Bulletin 10000000194-8 05ARAS
s
Automatic
Transfer Switches
GENERAC®
Service and non -Service rated
Automatic Smart Transfer Switches
100 - 400 Amps, Single Phase
C @US
LISTED
'CUL only applies to non -service rated switches
Description
Generac Automatic Transfer Switches are designed for use with single phase generators that utilize an Evolution'" or Nexus'"
Controller. The 100, 200, and 400 amp open transition switches are available in single phase in both service equipment rated and
non -service equipment rated configurations. The 150 and 300 amp open transition switches are only available in a service rated
equipment configuration.
Standard Features
Service rated (RTSW) Generac Automatic Transfer Switches are housed in an aluminum NEMA/UL Type 3R enclosure", with
electrostatically applied and baked powder paint. The Heavy Duty Generac Contactor is a UL recognized device, designed for
years of service. The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands. All
switches are covered by a 5 year limited warranty.
Non -service rated (RISC) switches are housed in a steel enclosure.
DPM Technology
Through the use of digital power technology (DPM), these switches have the capability to manage up to 4 individual HVAC (24 VAC
controlled) loads with no additional hardware. When used in tandem with Smart Management Modules, up to 8 more loads can be
managed as well, providing the most installation efficient power management options available.
GENERAC'
100-400 Amps, Single Phase Automatic, Smart Transfer Switches
Functions
All timing and sensing functions originate in the generator controller
Utility voltage drop -out..
Timer to generator start.
Engine warm up delay...
Standby voltage sensor.
Utility voltage pickup.....
Re -transfer time delay...
Engine cool -down timer
Exerciser ......................
The transfer switch can he operated manually without power applied.
'When used in conjunction with units utilizing Evolution'" controls
Specifications
10 second factory set, adjustable between 2-1500 seconds by a qualified dealer'
............................................................................................................. 5 seconds
................................................................................................ 60% for 5 seconds
...................15 seconds
...................60 seconds
12 minutes every 7 days
Model
RTSC10OA3
RrSW10DA3
RTSW15OA3
RTSC200A3
RTSW20OA3
firSW300A3
RTSG400A3
RTSW400A3
Amps
100
100
150
200
200
300
400
400
Voltage
120/240, 10
120/240, 1e
120/240, 10
120/240, 10
120/240, 10
120/240, to
120/240, 10
120/240, 10
Load Transition Type
(Automatic)
Open Transition
Open Transition
Service Rated
Open Transition
Service Rated
Open Transition
Open Transition
Service Rated
Open Transition
Service Rated
Open Transition
Open Transition
Service Rated
Enclosure Type
NEMA(UL 3R
NEMANL 3R
NEMAIUL 3R
NEMA7UL 311
NEMA UL 313
NEMA(UL 3R
NEMA(UL 3R
NEMArUL 311
UL Rating
UUCUL
UL
UL
UUCUL
UL
UL
UUCUL
UL
Withstand Rating
(Amps)
10,000
10,000
22,000
10.000
1 22,000
22,000
22,000
22,000
Lug Range
1/0-#14
250MCM-#6
600 MGM - #4 or 1/0 - 250 MCM
Dimensions
Model
RTSC10oA3
RTSW100A3
WSW150A3
RTSC20oA3
RTSW200A3
RTSW300A3
RTSC400A3
RTSW400A3
HeIgM
H1
17.241437.9
17.24/437.9
26.75/679A
17,24/437.9
25.75/679.4
42.91/1089.9
31.25/793.8
2.91/1089A
(InJmm)
H2
20/508
201508
30/762
20/508
301762
40/1219.2
361914A
48/1219.2
Width
W1
12.5/317.5
12.5/317.5
10.5/266.7
12.5/317.5
10.51266.7
16.69/423.9
19.18/487.2
16.691423.9
(in/mm)
W2
14.6/370.8
14.6/370.8
13.5/342.9
14.6/370.8
13.5/342.9
21.82J554.2
241609.6
21.82254.2
epth(in./mm)
7.09/180.1
7.09/180.1
6.3/160.1
7.09/180.1
6.3/1fi0.1
10.06/255.510.06/255.5
10.06/255.5
lghf (IhsJltllas)
Ll
20/9.07
22.5/10.21
39/17.69
20/9.07
39/17.69
140/63.5
133/60.33
140/63.5
oePrw
GENERAC Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI53189 • generac.com
—� 1 02015 Generac Power Systems, Inc. AlIfights reserved. AM specifications am subject to change whhuut notice. Bu9eM 0L3205-8 Pdmed In U.S.A. 07/28/15