Loading...
HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online Page 1 of 2 Florida r RZ=A�i� BOS Home I Log In 1 User Registration I Hot Topics I submit Surcharge I Stats a Facts I Publications I contact Us I BCIS Site Map 1 unks 1 searcb I a� Product Approval pp USER: Public User Product Approval Menu > Product or Application Search > Application ust > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) FL5374-R5 Affirmation 2017 Approved IN SCANNED BY St. Loopcinantia1 East Coast Metals, Inc. 2301 West 8 Lane Hialeah, FL 33010 (305)885-9991 acastellanos@eastcoast-metals.com Tom Castellanos acastellanos@eastcoast-metals.com Tom Castellanos 2301 West 8 Lane Hialeah, FL 33010 (305)885-9991 tcastellanos@eastcoasL-meLais.com Howard Callender Jr. 2301 West 8 Lane Hialeah, FL 33010 (305)885-9991 hcallender@eastcoast-metals.com Roofing Roofing Accessories that are an Integral Part of the Roofing System Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report - Hardcopy Received Robert Nieminen PE-59166 Architectural Testing, Inc., an Intertek Company 12/31/2020 John W. Knezevich, PE ❑ Validation Checklist - Hardcopy Received FL5374 R5 COI 2015 01 COI Nieminen.odf Standard YSBL FRSA/TRI April 2012 (04-12) 2012 RAS 118 1995 RAS 119 1995 RAS 120 1995 SBCCI SSTD 11 1997 TAS 101 1995 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtV Sv8n7ODFXffAz... 11 /22/2019 Florida Building Code Online Page 2 of 2 Equivalence of Product Standards Certlfied By Sections from the Code 2I affirm that there are no changes in the new Florida Building Code which affect my product(s) and my product(s) are In compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity Oyes O No ON/A Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products FL5374 R5 CDC 2017 09 AFFIRMATION ECM FL5374 6th Edition (2017).odf Method 1 Option D 09/06/2017 09/06/2017 09/10/2017 FL # Model, Number or Name Description 5374.1 East Coast Metals Channel Metals Preformed metal channels designed for use as a hip & ridge base to which roof tiles are bonded. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL5374 R5 II 2015 03 FINAL ER ECM Trim Lock FL5374- R4.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-178 Created by Independent Third Party: Yes Other: 1.) Refer to Evaluation Report Sections 5.2 and 5.3 Evaluation Reports for Limits of Use in HVHZ and non-HVHZ Jurisdictions, FL5374 R5 AE 2015 03 FINAL ER ECM Trim respectively. 2.) The design pressure herein pertains to use Lock FL5374-R4.odf in non-HVHZ Jurisdictions In conjunction with Table lA of Created by Independent Third Party: Yes FRSA/TRI April 2012 (04-12). Refer to Tables 2A and 2B In the Evaluation Report for all options and associated allowable design pressures. Back Newt Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. CopyHobt 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to section 455.275 (1), Florida statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click bg2. Product Approval Accepts: ® ® ® ILRt'A M securily�merlucs• https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtV Sv8n7ODFXfAz... 11 /22/2019 Florida Building Code Online Page 1 of 2 BOS Home 1 Log In I User Registration I Hot Tombs I Submit surcharge ! Stats B Facts I Publirauons I Contad Us EMS site Map j Unks search Flon pr r r Product Approval SCANNED � USER: Public User BY • ikoLad Approval Menu > Product or AoolKation Search > Aooilcatlon U > Application Detail LttciP\ I�iin�% FL # FL6021-R1 Application Type Revision Code Version 2017 Application Status Approved Comments Archlved ❑ Product Manufacturer Vande Hey Raleigh Roof Tlle Manufacturing, Inc. Address/Phone/Email 1665 Bohm Drive Little Chute, WI 54140 (800)236-8453 Ext 223 brucemuleau@vmtlle.com Authorized Signature Bruce Rouleau brucerouleau@vrmtlle.com Technical Representative Bruce Rouleau Address/Phone/Email 1665 Bohm or Little Chute, WI 54140 (800) 236-8453 Ext 223 brucerouleau@vrmtlle.com Quality Assurance Representative Bruce Rouleau Address/Phone/Emall 1665 Bohm or Little Chute, WI 54140 (800) 236-8453 Ext 223 bmcemuleau@vrmtlle.com Category Roofing Subcategory Roofing Toes Compliance Method Test Report Testing Lab American Test Lab of South Florida, Inc. Quality Assurance Entity QAI Laboratories Quality Assurance Contract Expiration Date 12/31/2021 Validated By Jesus Gonzalez, P.E. 0 Validation Checklist - Hardcopy Received Certificate of Independence FL6021 RI COI Certifcate of Independence - bottom of test rot odf Referenced Standard and Year (of Standard) Standard Year ASTM C1492 2003 FRSA/TRI April 2012 2012 TAS 101 1995 TAS 102, 102(A) 1995 TAS 112 1995 Equivalence of Product Standards Certified By https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDqubl p/o2bsAruL 1 YPz... 11/22/2019 Flofida Building Code Online Page 2 of 2 Product Approval Method Date Submitted ' Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option B 04/09/2018 08/27/2018 08/27/2018 10/08/2018 FL # Model, Number or Name Description 6021.1 Vande Hey Raleigh Architectural Shake -Slate -Custom Brushed -Cotswold Stone-Rlviem Flat Roof Tile style concrete roofing tile Limits of Use Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Installation Instructions FL6021 RS II Flat Drawina.odf FL6021 113 II Installation Drawing - Flat The odf FL6021 RI If Vandehev Raleiah TRI Letter.odf Verified By: American Test Lab of South Florida, Inc. Other: Refer to Test Report and FRSA/TRI Tile Installation Test Reports Manual 2012 for overturning moment limitations of FL6021 R3 TR Flat - Restoring Moment Aerodynamic Multiplier RT0803.01-18.odf FL6021 RI TR Flat Concrete Roof Tile TAS 112.pdf mechanically attached tile systems. The TAS 112 Standard Specification for Concrete Roof I'lles requires quarterly re- testing for code compliance. 6021.2 Vande Hey Raleigh Architectural Igh Bairel'Sp na ina isYt-Concrete Roof I Roof Tile Limits of Use Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Installation Instructions FL6021 R3 II Installation Drawing - Barrell Tlle.odf FL6021 R3 II Spanish Drawing.odf FL6021 RI 11 Vandehev Raleigh TRI Letterm f Verified By: American Test Lab of South Florida, Inc. Other: Refer to Test Report and FRSA/TRI Tile Installation Test Reports Manual 2012 for overturning moment limitations of FL6021 RI TR Spanish - Restoring Moment Aerodynamic Multiol.odf mechanically attached the systems. The TAS 112 Standard Specification for Concrete Roof Tiles requires quarterly re- FL6021 R1 TR Spanish Barrel Roof Tile TAS 112 odf testing for code compliance. Back Next Contact :: 2501 Blair Stone goad. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund statement Under Florida law, email addresses are public records. If you do not want your a -mall address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which on be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click bt . Product Approval Accepts: ® N il-N M M s 4 sCCUI'ItyAEaTRICti https://www.floridabuilding.org/pr/pr_app_dtl.aspx?paratn=wGEVXQwtDqubl D/`2bsAruLlYPz... 11/22/2019 PROFILE DRAWINGS filly HIGH DARAFt SPANISH FILE a VANDE HEY RALEIGH STANDARD WEIGHT CONCRETE HIGH BARREL SPANISH TILE TECHNICAL DATA TILE PER APPROX APPROX APPROX SQUARE W ITH EXPOSURE POUNDS KGS PER SOS PER DIMENSIONS 3°HEADLAP PERTILE PERSQ SQMETER PALLET 17'1W X 13' 86 14' X 12' 1000 476 2.65 iupport pads tedock :lot TOP VIEW BOTTOM VIEW American Test Lab of South Florida attests that the sketch and dimensions provided herein is representative of the tiles tested by ATLSF as reported m Reports: RT0618.02-18 & RT0803.02- 18. \\\►11 I I I I//// \fix\�- NE N IV * No 43951 LL 11 Stephen W. Warter, P.E. Reg. State of Florida # 54395 American Test Lab of South Florida ephenDate: �2018.08.06 a rte.r `�l �14 8:14-04'00' TILE ROOFING N S T I T U T E P.O. Box 40337, Eugene OR 97404-0049 From: Rick Olson, President February 1,2018 RE: Letter for VandeHey Raleigh Tiles in Florida To whom it may concern; This letter is to confirm that VandeHey Raleigh is a member in good standing with the TRI and as such has access to our industry -based testing and uplifts resistance -engineering data that is on file with the Miami Dade County as an official Data NOA. The tiles manufactured by VandeHey Raleigh fit within the length and width requirements covered by all our research and therefore will be covered by the wind uplift resistance values found within the 51 Edition FRSA/TRI installation Guide for Florida that has been recognized by the FBC and complies with the new IBC/IRC 2012 codes including the ASCE-7-10 provisions for the newer wind uplift requirements. The same information is found in our TRI Installation Guide that carries a formal ICC/IBC code evaluation approval under Uniform ES ER-20165. These values are the same as found in the 5th Edition of the FRSA/TRI Installation Guide for Florida that is specifically named in the Florida Building Code. Copies of both guides may be downloaded from our website www.tileroofing.org under publications. The values for uplift resistance and the fastener options will meet the ASCE-7-10 provisions. VandeHey Roofing tiles are covered by these provisions and are acceptable products for use in Florida. I hope this helps to answer your question. Please feel free to contact me if you require any additional information. Sincerely, Rick Olson President & Technical Director P: 541-689-0366 F: 541-689-5530 E: Rolson@tileroofing.org