Loading...
HomeMy WebLinkAboutSURVEYS0J WQ L) ¢of JLLJ a.� 00 H0 ZO ZV LEGEND: CMP = CORRUGATED METAL PIPE CNS = COULD NOT SET CONIC = CONCRETE FFE = FINISHED FLOOR ELEVATION FND = FOUND IR = 5/8" IRON REBER IRC = 5/8" IRON REBAR WITH PLASTIC CAP PCOR = PROPERTY CORNER PCP = PERMANENT CONTROL POINT PL = PROPERTY LINE UE = UTILITY EASEMENT R/W = RIGHT-OF-WAY R = RADIUS OF CURVE L = LENGTH OF CURVE A = DELTA OF CURVE 0 = SET 5/8" IRON REBAR WITH PLASTIC CAP "AJP PSM 6330" jj. = PROPOSED GRADE Ho? tioea? Jig @ ('p'`aq 3a1-a,'& R Zo _n CO. F� _ n RECEIVED ved = Q DEC 0 6 2D19 b Permitting Departmen• St. Lucie County LEGAL DESCRIPTION: LOTS 4 & 5 IN BLOCK 1 OF CARDINAL GLADES, ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 11, PAGE 14. OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. SURVEY NOTES: 1. UNLESS OTHERWISE NOTED ONLY PLATTED EASEMENTS ARE SHOWN HEREON. 2. NO UNDERGROUND UTILITIES OR IMPROVEMENTS WERE LOCATED UNLESS OTHERWISE SHOWN. 3. THIS SITE LIES WITHIN FLOOD ZONE "X", ACCORDING TO THE FLOOD INSURANCE RATE MAP. COMMUNITY PANEL NO. 12111CO189 J, EFFECTIVE DATE FEBRUARY 16, 2012. 4. FLOOD ZONE SHOWN HEREON IS AN INTERPRETATION BY THE SURVEYOR AND IS PROVIDED AS A COURTESY. THE FLOOD ZONE SHOULD BE VERIFIED BY A DETERMINATION AGENCY. 5. BEARINGS SHOWN HEREON ARE BASED ON THE NORTH LINE OF LOT 4 ASSUMED TO BEAR S89'19'19"E. 6. ALL LOT DIMENSIONS SHOWN ARE PER PLAT UNLESS OTHERWISE NOTED. ALL SURVEY MEASUREMENTS ARE IN FEET. 7. ALL MAPPED FEATURES SHOWN HEREON ARE UNDER THE DIRECT SUPERVISION AND RESPONSIBILITY OF ALEXANDER J. PIAZZA PSM, INC. 8. SURVEY MAP AND REPORT OR THE COPIES THEREOF ARE NOT VALID WITHOUT THE ORIGINAL SIGNATURE AND SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. 9. ADDITIONS OR DELETIONS TO THE SURVEY MAP OR REPORT BY OTHER THAN THE SIGNING PARTY OR PARTIES IS PROHIBITED WITHOUT CONSENT OF THE SIGNING PARTY OR PARTIES. IFIED TO: GROZA BUILDERS, INC. J SUNNED BY St. Luciprnitr ALEXANDER J. PIAZZA PSM, INC. K:\BUILDERS\DNG2019\19 4687.DWt; W�.5 Surveying Mapping Consul8ng REF K:\ _ 619 SW BOtmore Street FLD CJM / RP �• �• JOB 19-4687 ® Port St Lucie, Florida 34963 Phony (772) 340-7770 1 OFF CJM ATE 7-15-19 XANDERR' P'P LBFM Fax (772) 340-2250 Pro �s`�dgal ' r ieygl',&*pper DATE REVISIONS: dBY. ICKD AdP SHEET 1 OF 1 DWG �934 F 1 or rya ShyQ7•t,l,(,j,gat•e, No.�4a 6330 C:\BUILDERS\DWG2019\19-4687.dwG. 12/6/2019 8:42:21 AM C` FDOH in St. Lucie County Environmental Health Site Plan Approved for Construction Supersedes All Previous Site Plans for OSTDS #5lonF-19` L1-1- l 8 Well # - % LEGEND: CMP = CORRUGATED METAL PIPE CNS = COULD NOT SET CONC = CONCRETE FFE = FINISHED FLOOR ELEVATION FND = FOUND IR = 5/8" IRON REBER IRC = 5/8" IRON REBAR WITH PLASTIC CAP PCOR = PROPERTY CORNER PCP = PERMANENT CONTROL POINT PL = PROPERTY LINE UE = UTILITY EASEMENT R/W = RIGHT—OF—WAY R = RADIUS OF CURVE L = LENGTH OF CURVE A = DELTA OF CURVE 0 = SET 5/8" IRON REBAR WITH PLASTIC CAP "AJP PSM 6330" ts.s = PROPOSED GRADE vile COP y MIN. SETBACK REQ. _ ?M FRONT Ld SIDES 'n 5 I JN y^ CNR SIDES o REAR q C ZNG.1�i� TECH. LEGAL DESCRIPTION: LOTS 4 & 5 IN BLOCK 1 OF CARDINAL GLADES, ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 11, PAGE 14, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. SURVEY NOTES: 1. UNLESS OTHERWISE NOTED ONLY PLATTED EASEMENTS ARE SHOWN HEREON. 2. NO UNDERGROUND UTILITIES OR IMPROVEMENTS WERE LOCATED UNLESS OTHERWISE SHOWN. 3. THIS SITE LIES WITHIN FLOOD ZONE "X ACCORDING TO THE FLOOD INSURANCE RATE MAP, COMMUNITY PANEL NO. 12111CO189 J, EFFECTIVE DATE FEBRUARY 16, 2012. 4. FLOOD ZONE SHOWN HEREON IS AN INTERPRETATION BY THE SURVEYOR AND IS PROVIDED AS A COURTESY. THE FLOOD ZONE SHOULD BE VERIFIED BY A DETERMINATION AGENCY. 5. BEARINGS SHOWN HEREON ARE BASED ON THE NORTH LINE OF LOT 4 ASSUMED TO BEAR S89'19'19"E. 6. ALL LOT DIMENSIONS SHOWN ARE PER PLAT UNLESS OTHERWISE NOTED. ALL SURVEY MEASUREMENTS ARE IN FEET. 7. ALL MAPPED FEATURES SHOWN HEREON ARE UNDER THE DIRECT SUPERVISION AND RESPONSIBILITY OF ALEXANDER J. PIAZZA PSM, INC. 8. SURVEY MAP AND REPORT OR THE COPIES THEREOF ARE NOT VALID WITHOUT THE ORIGINAL SIGNATURE AND SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. 9. ADDITIONS OR DELETIONS TO THE SURVEY MAP OR REPORT BY OTHER THAN THE SIGNING PARTY OR PARTIES IS PROHIBITED WITHOUT CONSENT OF THE SIGNING PARTY OR PARTIES. CERTIFIED TO: SCANNED FND 4 GROZA BUILDERS, INC. Lay 6,� CONC MONUMEENTNT St. LucieC®univ 0.1 WE LAST FIELD DATE: 7-16-19 �sw' Is?- i ALEXANDER J. PIAZZA PSM, INC. Surveying • Mapping • Consulting 619 SW B➢tmore Street ® Port St Lucie, Florida 34983 Phone: (772) 340-7770 LB/7280 Fax (772) 340-2250 """' K:\BUILDERS\Dwc2019\79�6B7.t)WG `e e N ,% sa o 's 'S ,(E OF ® Al AN RWA e Prg�s,oq, Sur eygr�t�1ppper I orr'��`'C'�Cta,(,i,gpdC NokN: 6330 REF K:\ FLD CJM / RP FB. PG. JOB 19-4687 OFF CJM DATE 7-15-19 DATE REVISIONS: BY: CKD AJP SHEET 1 OF 1 DWG C-893 J I S7, L4(zlo G6uFItp1=c�(