Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
60 CELL MODULE MANUAL
MONO POLY 0 HELIENE 60m 60-CELL MONOCRYSTALLINE MODULE SCANNED By % J uria/'nnnh, COMBINING PROVEN EUROPEAN TECHNOLOGY I WITH NORTH AMERICAN INGENUITY ALLOWS HELIENE TO MAKE A REAL COMMITMENT IN I PROVIDING SMARTER ENERGY CHOICES FOR I THE FUTURE. HELIENE www.heliene_com GUARANTEED POSITIVE POWER SORTING: [-0 : +4.99 WP) DESIGNED FOR 1500V OC APPLICATIONS f MANUFACTURED ACCORDING TO INTERNATIONAL �J QUALITY SYSTEM STANDARDS:IS09001 H-BLACK INTEGRATION AVAILABLE (ALL -BLACK MODULE) LINEAR PERFORMANCE GUARANTEE us Ours n lMusuy Slaueard ,00.ea% ADDED VQIUCFR041 fJEU f AF WA S EAR Rggpn, MIEE us •. •. •- —« n Vear sar . ■ ELECTRICAL DATA(STC) Peak Rated Power P." (W) 305 300 295 299 285 Maximum Power Voltage V,(V) 33.44 33.14 32.84 32.537 32.236 Maximum Power Current Impp (A) 9.196 9.127 9.06 8.989 8.92 Open Circuit Voltage Vx (V) l 39.981 39.83 39.68 39.528 39.38 Short Circuit Current Isc(A) -9.673 9.59 9.51 9.424 9.34 Module Efficiency * Eff (%) 18.9 18.6 18.3 16.0 17.7 Power Output Tolerance - _L-0,+4.991 Wp STC - Standard Test Conditions: Irradiation 1000 W/m2 - Air mass AM 1.5 - Cell temperature 25 °C * Calculated using maximum power based on full positive output tolerance (-0,+4.99) Wp MECHANICAL DATA Dimensions(L x W x of 1650 x 992 x 40 mm(65 x 39 x 1.6 inch) Weight* 20 k9(43.9 lbs) Output Cables 1.1 on (43.3 inch) symmetrical cables with MC4 type connectors Junction Box IP-67 rated with bypass diodes Frame Double webbed 15 micron anodized aluminum alloy Front Glass Low -iron content, high -transmission Pit solar glass Solar Cells 60 Monocrystalline cells (156 x 156mm) " Calculated using 3.2mm PV glass, if 4mm profile is requested weight load will vary CERTIFICATIONS UL Listed ULC/ORO-C1703-1 , 111.1703, UL1703 Fire Classification Type 1 IEC Listed IEC 61215, IEC 61730 All Relieve modules are certified under the California Energy Commision (CEC) Listing Report TEMPERATURE RATINGS PACKAGING CONFIGURATION Nominal Operating Cell +4� 5 Temperature(NOCT) j Temperature Coefficient of Pm„ -0.39%/°C Temperature Coefficient of Va -0.31%/`C Temperahue Coefficient of Ip 0.045%/°C MAXIMUM RATINGS Operational Temperature-40°C-+85°C Max System Voltage_ 1590V(UL/IEC) Max Series Fuse Rating 15 A WARRANTY 10 Year Manufacturer's Workmanship Warranty 25 Year Linear Power Guarantee (Refer to product warranty page for details) Maddesper box:. 25 pieces Modules per 53'trailer. 750pieces CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. p * © 2016 Heliene Inc. All rights reserved. Specifications included in this datasheet are subject to HELIENE — change without notice. Data Sheet Enphase Microinverters Region: AMERICAS Enphase IQ 7 and IQ 7+ Microinverters To learn more about Enphase offerings, visit enphase.com The high-powered smart grid -ready Enphase IQ 7 Micro'" and Enphase IQ 7+ Micro'"' dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy"', Enphase IQ Battery'", and the Enphase Enlighten'" monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. Easy to Install • Lightweight and simple Faster installation with improved, lighter two -wire cabling Built-in rapid shutdown compliant (NEC 2014 &2017) Productive and Reliable Optimized for high powered 60-cell and 72-cell* modules More than a million hours of testing Class II double -insulated enclosure UL listed Smart Grid Ready Complies with advanced grid support, voltage and frequency ride -through requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) -The IQ 7+ Micro is required to support 72-cell modules. n ENPHASE. Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA (DC) I07-60-2-US/IQ7-60-B-US IQ7PLUS-72-2-US / IQ7PLUS-72-B-US Commonly used module pairings' 235'W-350 W+ - - 235W-440W+ Module compatibility 50-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27V-37V 27V-45V dperating range 16 V-48 V 16 V - 66 V Min/Max start voltage 22 V / 48 V 22 V / 60 V Max DC short circuit current Isc) 15 A 15 _(_module 6vervoltage class DC port II 1 _ bC port baclfeed current 0 A _ 0 A_ PV array configuration 1 x 1 ungrounded array; No additional _ DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter Peak output power - - 250 VA _ - 295VA Maximum continuous output power _ _ 240 VA _ 290 VA 'Nominal (L L)Joltag_e%renge' 240V/ 208V/ � 240V! 208V% 183-229 V V Maximum continuous output current _2_11-264V _ 1.0 A (240 V) 1.15 A (208 V) _ _211_-264_V _ _183-2_29 1.21 A (240 V) 1.39 A (208 V) Nominal frequency 60 Hz � 60 Hz, ' Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault current over cycles 5:8 Arms 5.8 Arms _ Maximum units per 20 A (L-L) branch circuit' __ - 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (2-08 VAC) Overvoltage class AC port AC port backfeed current 0 A 0 A ' Polder factor setting 1.0 1.0 Power factor(adiustable) 0.85 leading... 0.85 lagging 0.85 leading... 0.85 lagging CEC weighted efficiency 970 % 970 % 97.0 MECHANICAL DATA 'Ambienttempera turerange _ _ -40-Ct6+65°C Relative humidity range 4%to 100%(condensing) Connectdrtype(IQ7-60.2 _US'&iQ7PLl1§72-2d1S) PA(or Amptierol H4.UTX Withad_dtlonal Q.DcC_5..ad-aap'tei - C4 6onnectortype(IQ7-60-B-US&IQ7PLUS-72-B-US) Friends PV2(MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: - PV2 to MC4: order ECA-S20-S22 - PV2 to UTX: order ECA-S20-S25 _ ,- _ ._. Dim_ensiona (WxHxO)_ _ _ � _._ _ .__. _,,,__ _____ ._..-.,__- _._...._. _212 mm x 175 mmx.30.2 mm (without bracket) , Weight 1.08 kg (2.38 lbs) i Cooling Natural convection -No fans I Approved for wet locations Yes r 15ollution degree - PD3 Enclosure Class II double -insulated, corrosion resistant polymeric enclosure __._____. ______...—____._ . —_ ' Environmental category/UVexposure rating ___—____._____—._..___._..�_._.._ NEMA T_ype6/outdoor FEATURES " Communication Power Line Communication (PLC) - I Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. N— __-._ ___ ___ _______ means --k-- d—b.ezisconnecting ' disconnect required by NEC 690. Compliance CARule21 (UL1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. 1. No enforced DC/AC ratio. Seethe compatibility calculator at httos'//enphase.com/en-uststipport/module-compat b lity. 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com v EN P HAS E. © 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2018-11-19