HomeMy WebLinkAboutSOLAR SYSTEM PLANSA SOLAR PV SYSTEM IMPROVEMENT FOR0 : SEP 112019 ST. Lucle County, Permittln9 WRIG -H T RESIDENCE SOLAR IMPROVEMENT CONSTRUCTION DOCUMENTS FOR THE EXISTING RESIDENTIAL GRID TIED ELECTRICAL /:TynA'�- VICINITY MAP f \Y¢aIOHOPe Rp � ',•}EYI¢SpCID¢ORtl ' Wealheibee NuneryQ 5 v, PROJECT SITE LOCATION FOR SOLAp IMPROVEMENT I� f. jj44 Y4609 PinBLree;Orive oYna Ava ST.LUCIE COUNTY PLAN REVIEW BLDG: DATE: .{]� �/ ELE;gg:{,E�N DAT . -13-/QT PLUMB: DATE. MECH: DATE: u, o �w SYSTEM o in -III z =o FILE COPY �� w �k W � M INDEX SHEET DRAWING NAME w a w w00 CV COVERSHEET o -- (A LL d LL. ;¢ SLR SOLAR SYSTEM EQUIPMENT LOCATION PLAN C Z � DATE 08/22/2019 PVR-SS ROOF ATTACHMENT DETAIL -SOLAR ELECTRIC DRAWN BY: 1LL EW.uh nR SLR2 ELECTRICAL 3-LINE DIAGRAM WITH CALCULATIONS s o CHKD BY. ILA: oREC. NO. # 29127 s s' SCALE AS NOTED - -------- APPENDIX -------- St. DRAWING# HB1021 NEW PROVISION + LETTER L 111 9 HELIENE 30OW MODULE DATA SHEET `\c�i s ub AN ENPHASEIQ7+ MICROINVERTER DATA SHEET LN.`.'1.MPf a� a4 vets f�ou' ou, �€• 'n P6 • DYAI�EP L3I� ^ - .n � i ,� E AL \���• �7j11j I 6-1 I" 17•-10" I 4' 0" IRONRIDGE XR1 DO SOLAR RAIL LYP 2 PLCS PER MODULEARRAY HEUENE 300 W MODULETYP. APPROXIMATE LOCATION OF S-51 PR07EA BRACKET CONNECTIOM SEE SHEET PVRSS FOR DETAILS. ROOFTOP JUNCTION BOX APPROXIMATE LOCATION FOR WIRE TRANSITION. SEE SHEET SLR2 WIND ZONE 3 LOCATION TYP. ITAPPROXIMATE LOCATION OF DISTRIBUTION PANEL LOCATED INSIDE BUILDING. OF ENPHASE (MATE ENVOY SON OF ENPHASE ENVOYS c COMBINER BOX RESIDENTIAL ROOF LAYOUT - WIND ZONES - PV MODULE LAYOUT AND EQUIPMENT LOCATION PLAN SCALE: N.T.S. MATERIALS REQUIRED: (22) HEUENE 30OW MODULES W/ (22) ENPHASE IQ7+ MICROINVERTERS (11) IRONRIDGE MICROINVERTER MOUNTING KITS (NOTE: EACH KIT COMES WITH 2 BOLTS) (8) l l' XR100 RAIL (4) 17' XR100 RAIL (4) XR1 00 INTERNAL SPLICE KITS (4) GROUNDING LUGS FOR ARRAY CONNECTIONS OF #6 BARE COPPER (70) WIRE MANAGEMENT CLIPS (84) S-51 PROTEA BRACKETS (16) IRONRIDGE UFO SLEEVES (16) IRONRIDGE END CAPS FOR RAILS (52) IRONRIDGE GROUNDING UFO CLAMPS (22) LANDSCAPE OR PORTRAIT ENPHASE ENGAGE CABLE CONNECTORS (2) ENPHASE 6 FT EXTENSION CABLE (2) ENPHASE END CAPS (2) NEMA 3R RATED ROOF MOUNTED JUNCTION BOXES DISCLAIMER: MATERIALS REQUIRED LIST FOR CONCEPTUAL USE ONLY THE INTENT IS TO AID CONTRACTOR FOR ORDERING REQUIRED MATERIALS FOR THE PROJECT. CONTRACTOR RESPONSIBLE TO VERIFY PRIOR TO SOLAR EQUIPMENT ORDERING. C�Q` V IN. SETBACK REQ. FRONT a SIDES CNR SIDES `J REAR ZNG. TECH. I PROJECT: I d u � Z w u, jzj w w Z � a O O z 'q N h 0` La W V W G 0 > Za uT N H H U K W W w O 00 a DATE OB/22/2019 DRAWN BY: 1LL CHKD BY: 11A REC. N0. # 29127 SCALE AS NOTED \XY 411f7 ROOF LAYOUT NOTE: N .; '_ SOLAR PANEL LAYOUT IS CONCEPTUAL, BUT AS PROVIDED, CONFORMS WITH THE REQUIREMENTS SET IN _ 0. 813 ir, SHEET PVR-SS FOR SPECIFIED ADDRESS. CONTRACTOR MAY ADJUST PANEL LOCATION, BUT SHALL CONFORM TO THE REQUIREMENTS ON SHEET PVR-SS. SOLID AREAS ON CORNERS OF ROOF ARE WIND '0 _ ZONE 3AREAS. -0 TATE OF z �; '�7,�YJ J AL 1Y1XX�� NOTES: 1. APPUCABLE CODE: 2017 FLORIDA BUILDING CODE (6TH EDITION( & ASCE 7-10 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES. 2. ALL SELF DRILLING SCREWS THIS SHEET SHALL BE STAINLESS STEELa" - 14 DP3 UNLESS OTHERWISE NOTED. 3. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR TYPICAL HIP AND GABLE ROOFS, CONSIDERING FROM A 7" TO A MAXIMUM 27" ROOF SLOPE IN SCHEDULE CONTRACTOR SHALL FIELD VERIFY THAT EXISTING FACILITY HEIGHT IS LESS THAN OR EQUAL TO 30 FT. 4. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511, AND IS THE RESPONSIBILITY OF THE CONTRACTOR TO PILOT FILL ALL HOLES. 5. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TO MANUFACTURER MANUAL FOR ALL ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND SOLAR SPECS. 6. ALL ALUMINUM COMPONENTS SHALL BE ANODIZED ALUMINUM 6105-T5 UNLESS OTHERWISE NOTED. 7. ALL 39" X 65" 60 CELL MODULES MAY BE INSTALLED PER THIS CONNECTION DRAWING. B. ALL MODULES AND SOLAR RAIL SHALL BE INSTALLED PER MANUF. INSTRUCTIONS. 9. ALL DISSIMILAR MATERIALS SHALL BE SEPARATED WITH NEOPRENE OR SIMILAR. _ 10-CONTRACTOR SHALL ENSURE ALL ROOF PENETRATIONS TO BE INSTALLED AND SEALED PER 2017 HAS BEEN INSTALLED PER RAS 133 STANDARDS. ULTIMATE V"wWIND VmeWIND V",a WIND WIND ZONE I&2 WIND ZONE WIND SPEED PRESSURES PRESSURES PRESSURES MAX SPAN, MAX MAX SPAN, MAX V.(MPH) ZONE 1 PST) ZONE 2 (PSFI ZONE 3 (PSF) CANTILEVER CANTILEVER 160 26.6,-42.0 26.6,-73.2 26.6,.108.2 24"O.C., 9"O.C. 12"O.C., 5"O.C. - SCHEDULE REFLECTS COMPONENTS AND CLADDING (C&C) NOMINAL WIND PRESSURES WITH EXPOSURE "D", RISK CATEGORY II, ENCLOSED BUILDING AND h < 60'-0" PER ASCE 7-10 "MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES" AND 2017 F.B.C. NOTE: ATTACH S-51 PROTEA BRACKET AS SHOWN IN DETAILS 2&3 AND INSTALL PER MANUF. RECOMMENDATIONS. RAIL AND SOLAR PV MODULE ATTACHMENT NOT SHOWN FOR CLARITY. CONTRACTOR RESPONSIBLE TO FIELD VERIFY DIMENSIONS AND CONDITIONS SHOWN FOR EXISTING ROOFING. S-51 PROTEA BRACKET ASSEMBLY W/ (4) 6mm x 25mm SELF DRILLING SCREWS (OR EQUAL FASTENERS) TYP. EXISTING 26 GA GALVALUME METAL ROOF TO REMAIN S-5! PROTEA BRACKET ATTACHMENT ISOMETRIC SCALE: N.T.S. WIND ZONES ARE INDICATED BELOW ON ROOF PLAN. "a" DIMENSION PER ASCE 7-10 IS 7.1 BASED ON THE LEAST HORIZONTAL DIMENSION OF THE BUILDING PER 2017 FLORIDA BUILDING CODE (SIXTH EDITION). I GABLE END BUILDING ROOF WIND AREA ZONES .dE IC 51 Ya alp �r*,hI IMIui LNnU7uIIr �Li4 iT EClt,, �1ir ]Y31XaIE IJ,101L ,i€lt 71Ms �1 ---------------------- / HIP END BUILDING ROOF WIND AREA ZONES / / I _ / I'I �1"RC ilL1GsL��IZP134 1��r=F�l'aBL ^�Ift°�-,cuter% i f 3Iit`�E#Li TR'kI'lli ur U VirS6. t mf S �417 hiV{11 a iIT h75n SPACING OF RAIL CONNECTION TO MODULE SHALL BE FASTENED TO MODULES TYP. 2 PLCS. PER MODULE ARRAY AND BE CONNECTED LESS THAN 25% OF MODULE LENGTH. USE MAAN AND TIGHTEN TO TORQUE PER MANUF. INSTRUCTIONS S-5! PROTEA VERTICAL L BRACKET ASSEMBLY TYP. MODULE TYP 16 HEX CAP ST STL BOLT AND ST ST SERRATED FLANGE -NUT TYP. IRONRIDGE — XR100 SOLAR -a RAIL TYP. IRONRIDGE UFO LAMP END SLEEVE TYP. (4) 6mm x 25mm SELF DRILLING SCREWS SLEEVE SIZE VARIES. (OR EQUAL FASTENERS) TYP. INCLUDED WITH S-5 CLAMP AND TO BE INSTALLED EXISTING 26 GA GALVALUME PER MANUF. RECOMMENDATIONS CORRUGATED METAL ROOF TO REMAIN TYP. TYPICAL PV SOLAR RAIL END CONNECTION DETAIL SCALE: 1 2"'=V-0^ PVR S-5! PROTEA VERTICAL L PHOTOVOLTAIC BRACKET ASSEMBLY TYP. MODULE TYP. 16 HEX CAP ST STL BOLT AND ST STL SERRATED �IRONRIDGE UFO CLAMP TYP. FLANGE NUT TYP. TYPICAL HIP AND GABLE ROOF - PHOTOVOLTAIC PANEL ROOF LOCATION PLAN SCALE: 16"=1' 0" (4) 6mm x 25mm SELF DRILLING' SCREWS (OR EQUAL FASTENERS) TYP. INCLUDED WITH S-5 CLAMP AND TO BE INSTALLED PER MANUF. RECOMMENDATIONS IRONRIDGE XR100 SOLAR RAIL TYP. \-EXISTING RIGID INSULATION TO REMAIN TYP. C EXISTING 26 GA GALVALUME CORRUGATED METAL ROOF ` TO REMAIN TYP. TYPICAL PV SOLAR RAIL MID CONNECTION DETAIL SCALE: 1 ;"=1' D" 0 a CD O VZ wp ,iO U. Ov 0, az �d .O a U �Z NE _0 3rim O Cno 4<LL < 11— �Q www di 0uLL DATE 8-22-2019 DRAWN BY I JUL CHKD BY: I ILA RECORD #: 29121 SCALE: AS NOTED DRAWING # 77j1VNAI-` 0 'OWER TABLE: SYSTEMA SYSTEM B UtNtKAL YHUI L)VULIAIL- 3-LIN[ UTAUKAM 3E'CUDII. fLAU I' OBTAIN ALL PERMITS AND APPROVALS FROM GOVERNING AGENCIES PRIOR TO THE COMMENCEMENT OF WORK DC -SIDE A B C 1 ST BRNCH C 2ND BRNC AC -SIDE t PV MODULE 1 1 12 10 INVERTER MANUF HELIENE 9NPHASE.IQ7+ EQUIPMENT SHALL BE INSTALLED PER THE 2014 NATIONAL ELECTRICAL CODE (NEC), ALL APPLICABLE OR GOVERNING CODES, MANUFACTURER REQUIREMENTS OF AND PER THE GOVERNING UTILITY COMPANY . MODEL 60M 295 W 3540 W 2950 W PEAK POWER POWER 300 Wp-dc 290 W 3480 W 2900 W CONT. POWER USTING AGENT NAME AND NUMBER SHALL BE INDICATED PER NEC 110.3(B). ENPHASE MICROINVERTER SYSTEM 15 RAPID SHUTDOWN COMPLIANT PER NEC 690.12. VOC 39.83 VDC 240 VAC 240 VAC 240 VAC VOLTAGE ISC 9.59 A 1.21 A 14.52 A 12.10 A CURRENT VMP 33.14 VDC 60 HZ 60 HZ 60 HZ FREQUENCY TO PREVENT AN INCREASE IN AC VOLTAGE LEVEL AND AVOID ANY NUISANCE FAULTS, IT IS RECOMMENDED TO SIZE CONDUCTOR FOR A 4 TOTAL VOLTAGE DROP OF 2%OR LESS PER INVERTER MANUFACTURER. IMP 9.127 AMP '—SIC: CELL TEMPERATURE @ 25' C, SPECTRUM AM1.5, IRRADIANCE @ 1000 W/M2 — AABEL DEVICE PER NEC 690.14(CI(2), AND SECURE PER NEC 690.7(D). 3Q A B ENPHASE DROP CABLESYSIEM C IM/ DOOR U NDITIO011TCABIf Q ONDOORCONgHONS 0 DRUAWG, WSULA110W PIIM/THWN2 SYSTEMA - oR6110AV p) # 10 AW G, GROIPJD CONDOCf00. _ rCONWRMM4NUM INDOOR CONDITIONS 10-2 W RONEX CABLE, Ui CABIA OR EQUAL ENPMSE107i — P 5 — — — W/#IOGROUND NJCROINVFAR0.TTP. "- ONEN OFUNN WSTAIIED Q Q ONENATODNPHASEAIJUED 5 B LI CARE SYSTEM u Q 6 FNPHASEOCABLE SYSTEM P'PHASEOCAIU: SYSiDA AWG SOLD CU EQUIPMENT ROUNp PO0. CONT RUNT GROUNDING 0 7 NEC 2014 LABELING REQUIREMENTS PHOTOVOLTAIC AC DISCONNECT MAXIMUM AC OPERATING CURRENT: 26.62A CAUTION MAXIMUM AC OPERATING VOLTAGE: 240 V IPEFMCO.-P.WNAIEXTERWIAC SOLAR ELECTRIC SYSTEM OSCONNECRM N SERNR PANEVNFWSERVICEMNEL MR sOIMPY6P➢ruuelLl LABEL PER NEC 90.25&NC 69D.1D MAIN PV SYSTEM 3(B). PROVIDE AT DISCONNECTNEW OR EXISTING SUB PANEL OR SERVICE PANEL WARNINGPER NEC 69D.15&NEC 690.131B)-PROVIDE AT PHOTOVOLTAIC SYSTEM DEDICATED SOLAR PANEL DO MAIN SERVICE PANEL OR NEW SERVICE PANEL FOR EQUIPPED WITH RAPID NOT CONNECT ANY LOADS SOLAR PV FOR SUPPLY SIDE CONNECTION SHUTDOWN LABEL PER NEC RSERVI SERVICE JDE AT (IF REQUIRED) SUB LABEL PER NEC SERVICE PANELF PROVIDE SHUTDOT NEW WN PANEL DR SERVICE PANEL (IF REQUIRE0) PANEL ORSERVICE PANEL FOR RAPID SHUTDOWN WARNING COMPUANTSYSTEMS. WARNING CAUTION ELECTRIC SHOCK HAZARD. DO NOT TOUCH PHOTOVOLTAIC SYSTEM Cl RCU IT DUAL POWER SOURCE TERMINALS. TERMINALS ON BOTH THE LINE WARNING IS BACKFED SECOND SOURCE IS PV SYSTEM AND LOAD SIDES MAY BE ENERGIZED IN THE INVERTER OUTPUT CONNECTION - DO NOT LABEL PER NEC 705.12I01(3-0)&NEC 690.64 LABEL PER NEC 705.12(D)(3)&NEC 690.64- OPEN POSITION RELOCATE THIS OVERCURRENT DEVICE PROVIDE AT NEW OR EXISTING SUB PANEL OR PROVIDE AT MAIN SERVICE PANEL OR TAP BOX LABELPER NEC WO.OIE)- PROVIDE AT MIN SERVICE PANEL )ARM PER NEC70S]21011E)ON- PROVIDE AT MAIN 5ER00E MNCE SERVICE PANEL LOCATION COMSWERBOX OUTPIRCIRCUTT CAELE OUTDOOR CONORIOM 13198 AWG, INSULIPON� THHN/RIWN-2 OR SIMILAR 11)#10 AWG, GROUND CONDUCTOR i-mmMMIMMUM NEW BOA RATED RNPMSE IQ COMBINER 20A/2P BOX RUNG 2DCA MAW SERVICE PN CONN CDNG TO U M METER (REND VERIFY) NEW 9A NON FUSED DISCONNCC IF RED BY URUT11 SYSTEM B SYSTEXBGIDS'llm TO SYSTENA SEE POWER TABLE FOUNDAllCRORNFRRR COUNT.NT. IY LABEL BREAKER PER NEC 690.54, 705.12(D) AND 705.10. ��§s o Oo 0 Ug PV BACKFEED CURRENT PLUS MAIN BREAKER RATING MUST BE LESS THAN OR � EQUAL TO 120%OF MAIN SERVICE BUS RATING AND BREAKERS MUST BEZL MOUNTED AT OPPOSITE END OF MAIN BREAKER PER NEC 705.12. ZLENPHASE Q CABLE SHALL BE KEPT I' ABOVE ROOF SURFACE MINIMUM a AgENPHASE Q CABLE SYSTEM DOES NOT CONTAIN A NEUTRAL AND IS NOT REQUIRED I MANUFACTURER. IQ6+MICROINVERTER DOES NOT REQUIRE EQUIPMENT BONDING FOR GROUNDING. SEE MANUFACTURER'S INSTALLATION MANUAL FOR DETAILS. J 10 TO EXISTING GROUNDING ELECTRODE ZL SUPPLY SIDE CONNECTION OPTION TO MIRY GRID 120/240 VAC SINGLE PHASE TOMANI BI-OIRCFONAL DISTRIBUTION PMR WITHMAW 11YP.) MIRY BREAKER KWHWER 30N D #10 A W G OB TO EXISPNG GRONNDWG EIECIROOE SUPPLY SIDE CONNECTIN COMPLY WIIR NEC705.12(A) DISCONNECT OUTPUT CIRCUIT (3) # 6AWG, WSLUVOR TMN/THWN-2 00141 TSM 'MINIMUM 60 AMP FUSED DLSCONNECT. LOCATE OUTDOOR AS SHOWN ON SHEET SIX.S G "I'VVICE RATED EWIPMEM 10 BOXODULTIORCM (3)A 6A W (1)#6AWG, ROUND CONDUCTOR 11I # TIRING, GROUND CONDUCTOR CONDUR SQL {' MINIMUM 0 7 NEW BOA RAT®ENPWSE 20A/2P IOCOMBINWI BOX 20 2P DA 2P SYSTEM A SYSTEM B I PROJECT: I C V � Z w DID o i— w Z rr IQ- 1— 1— Cf OO 1— LY cd 3 vR La C 0 Q N Z < LL N F H U Q LL W 04 uJ O � it u M- d LL DATE OB/22/2019 DRAWN BY: ILL CHKD BY: JIA REC. NO. # 29127 SCALE AS NOTED DRAWING # i No. 81 0 - _— — DOCIae NOul y]A. ¢ 10 WL*TELW:Lc a�'�� iO E#81305 Y` /7e NAt `� \ / ,ll ''/' 1 / 1 j L%LA••