Loading...
HomeMy WebLinkAboutTRUSS PAPERWORK4451 ST. LUCIE BLVD FORT PIERCE, FL 34946 af "t 0 Vic PH: 772-409-1010 FX: 772-409-1015 www.AlTruss.com TRUSS ENGINEERING BUILDER: PROJECT: COUNTY: LOT/BLK/MODEL: JOB#: MASTERM OPTIONS: 4 MORNINGSIDE ST LUCIE LOT:108 / MODEL:BERMUDA 1796 / ELEV:B3/ GAR L 77613 WRMSBMB3 LANAI 135 SQ FT W/ VALLEYS Lumber design values are in accordance with ANSIrl-PI 1-2014 section 6.3 A-1 ROOF These truss designs rely on lumber values established by others. = TRUSSES A FLORIDA CORPORATION RE: Job WRMSBMB3 A-1 Roof Trusses 4451 St Lucie Blvd Site Information: Fort Pierce, FL 34946 Customer Info: RENAR DEVELOPMENT CO. Project Name: MORNINGSIDE Lot/Block: 108 Model: BERMUDA 1796 Address: 9760 PALM BREEZES DRIVE Subdivision: City: County: St Lucie State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017[TP]2014 Design Program: MiTek 20/20 8.2 Wind Code: ASCE 7-10 Wind Speed: 160 Roof Load: 37.0 psf Floor Load: 0.0 psf This package includes 48 individual, dated Truss Design Drawings and 16 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003,section 5 of the Florida Board of Professional Engineers Rules. No. Seal # Truss Name Date No. Seal # Truss Name Date No. Seal # Truss Name Date 1 A0133434 ANG 8115119 13 A0133446 B02 8/15119 25 A0133458 CJ3B 8/15119 2 A0133435 A02 8115/19 14 A0133447 C01G 8/15/19 26 A0133459 CJ5 8115119 3 A0133436 A03 8/15/19 15 A0133448 CO2 8/15119 27 A0133460 CJ5A 8115/19 4 A0133437 A04 8/15119 16 A0133449 CO3 8/15/19 28 A0133461 CJ5B 8115/19 5 A0133438 A05 8/15/19 17 A0133450 C04G 8/15/19 29 A0133462 D03G 8115/19 6 A0133439 A09 8/15/19 18 A0133451 C05 8/15/19 30 A0133463 D04 8115/19 7 A0133440 A10 8/15/19 19 A0133452 CJ1 8/15/19 31 A0133464 D05 8115/19 8 A0133441 All 8/15/19 20 A0133453 CAA 8/15/19 32 A0133465 E01SGE 8115/19 9 A0133442 Al2 8/15/19 21 A0133454 CAB 8/15/19 33 A0133466 E02 8115119 10 A0133443 A13 8/15/19 22 A0133455 CJ1C 8115/19 34 A0133467 HJ2 8115/19 11 A0133444 A14G 8/151119LI 23 A0133456 CJ3 8115/19 35 A0133468 HJ3 8115/19 12 IA0133445 I B01G 8/15119 24 IA0133457 I CJ3A 8115/19 36 AM33469 HA 8115(19 'he truss drawing(s) referenced have been prepared byW hole House Engineering, Inc. undermydirectsupervision based on the parameters provided byA-1 Roorriusses, W. NOTE. -The seal on these drawings indicate acceptance of professlonalengineering responsibTnysok:lyforthe truss components shown. The suitablityand use of components forany padicularbulding Lsthemsponslbilityofthe building desgner,pv ANSIrrPL1 Seel The Truss Design Diawing(s)(I'DD[s)) referenced have been prepared based on the construction documents (also referred to attunes as'Structural Engineering Documents') provided bythe Building Designerindkating the nature and chamaterof the work The design cdW&therein have been transferred to the Truss Design Englneerby [Al RoofTnrsses or specific location]. These TDDs (also referred to attunes as'Structural Delegated Engineering Documents') am, specialty stnrcturalwmponent designs and maybe part of the pmject's deferred or phased submittals. As a Truss Design Engineer (Le, Specialty Engineer), the seal hem and on the TDD represents an acceptance of professional engineering responsibPnyforthe design of the single Tmss depicted on the TDD only. The Building DeelgnerIs responsible forand shall coordinate and review the TDDs for compatibililywlth thelrwdlten engineering requirements. Please review all TDDs and all related notes. Awelf W aA (LAICh IL` !rw&W-4,sN Page 1of2 FL L.LC, /tK-00(130i i �P7 �LCENSF ..O No. 62809 —_ STATE OF -----__...._.�.... .,,off, . •...... N� %. /onlbt E ��•• Tmss Desgn Engineers License mnewaldate! ! I I I I III l 1 ty\ forthe state of Florida's February 28,2021 SERIAL# 5f05498050098feb 19a649f 4451 St. Lucie Blvd. Fort Pierce, FL 34946 ROOF *=--TRUSSES ARORIDACORPORATION RE: Job WRMSBMB3 No. Seal # Truss Name Date HJ5 8115/19 37 A0133470 38 A0133471 HJ7 8/15/19 39 A0133472 HHA 8/15/19 40 A0133473 J2 8/15/19 41 AO133474 J4 8/15/19 42 A0133475 J4A 8/15/19 43 A0133476 J5 8/15/19 44 A0133477 J7 8/15119 45 A0133478 J7B 8/15/19 46 A0133479 VO4 8115119 47 A0133480 V08 8/15119 48 A0133481 V12 8/15/19 49 STDL01 STD. DETAIL 8/15/19 50 STDL02 STD. DETAIL 8/15/19 51 STDL03 STD. DETAIL 8115/19 52 STDL04 STD. DETAIL 8115/19 53 STDL05 STD. DETAIL 8/15/19 54 STDL06 STD. DETAIL 8/15/19 55 STDL07 STD. DETAIL 8/15/19 56 STDL08 STD. DETAIL 8/15/19 57 STDL09 STD. DETAIL 8115/19 58 STDL10 STD. DETAIL 8/15/19 59 STDL11 STD. DETAIL 8/15/19 60 STDL12 STD. DETAIL 8/15/19 61 STDL13 STD. DETAIL 8/15/19 62 STDL14 STD. DETAIL 8/15119 63 STDL15 I STD. DETAIL 8/15119 64 1 STDL16 I STD. DETAIL 8115119 r Lumber design values are in accordance with ANSIffPI 1-2014 section 6.3 These truss designs rely on lumber values established by others. ixa.lw�. �emeen.c u s1 ai s Page 2of2 R Fame.RNB18 09e: Ofl�lYA18 ,fob Truss Truss Type City Ply RENARMORNINGSIDE WRMSBMB3 A01G Roof Special Structural Gable 1 1 A0133434 Jos Reference (optional) A-1 Roof Twsses, Fort Pierce, FL 34946. design(caltruss.mm LOADING (Pat) SPACING- 2-M TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 ' Rep Stress Incr NO BCDL 10.0 Code FBC2017/rP12014 LUMBER - TOP CHORD 2x4 SP No.2 BOTCHORD 2x4 SP N0.2 *Except* B2,B5: 2x4 SP No.3 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-6-8 oc pudins. BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing. Except: 10-0-0 oc bracing: 23-25, 18-20 JOINTS 1 Brace at Jt(s): 20 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 0-8-0 except (jt=length) 21=0-10-4, 22=0-10-0. (lb) - Max Horz 2=197(1-C 13) Max Uplift All uplift 1001b or less at joint(s) except 2=-136(LC 12), 21=-577(LC 13), 22=-474(LC 12), 13=-239(LC 13) Max Grav All reactions 2501b or less at joint(s) except 2=470(LC 23), 21=1076(LC 24), 22=822(LC 23), 13=756(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-0=-480/390, 4-5=0/254, 8-9=0/251, 10-11=321/453, 11-12=-4301432, 12-13=-1016/672 BOTCHORD 2-26=-108/380, 4-23=0/423, 22-23=1 0 1 /360, 22-50=-265/355, 21-50=265/355, 20-21 =-1 251455, 9-20=-184/619, 16-17=-411/837, 15-16=-411/837,13-15=-011/837 WEBS 23-26=1031418, 3-23=-388/446, Continued on page 2 Run: 8.310 s 21 May 18 2018 Print: 8.210 s May 18 2018 MTek Industries, Inc. Mon Sep 17 11:33:34 2018 Page 1 6.00 F12 516 = 3x4 G 3x6 i 2x4 It 8.8 = 3x4 = CSI. TC 0.79 SC 0.68 WB 0.66 Matrix -MS 7 8 4.6 A-n\ 9 19 18 2x4 II 17 3x8= 3x6= Dead Load Dell. = 1/8 in DEFL. in (too) I/defl Ud PLATES GRIP Vert(LL) 0.1515-49 >999 360 MT20 244/190 Vert(CT) -0.25 1S-49 >928 240 Horz(CT) 0.01 13 n/a n/a Weight:292Ib FT=10°/ WEBS 23-26=103/418, 3-23=-388/446, 17-20=0/390, 10-20=-434/584, 5-22=-445/225, 10-17=-289/290, 8-21=-433/131, 9-21=577282, 4-22=-370/2, 12-17=-644/542, 12-15=0/328 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) C-C vend load user defined. 4) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/rPI 1. 5)All plates are 1.5x4 MT20 unless otherwise Indicated. 6) Gable studs spaced at 2-0-0 Do. 7) This truss has been designed for a 10.0 pat bottom chord live load nonconcurent with any other live loads. 8)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 136 lb uplift at joint 2, 5771b uplift at joint 21, 474 lb uplift at joint 22 and 2391b uplift at joint 13. 10) Load cese(s) 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16,17 hasihave been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. LOAD CASE(S) Standard Except: 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Standard Except: Uniform Loads (plf) Vert: 1-7=-54, 7-14=-54, 25-44=-20, 24-25=-20, 20-23=20, 18-19=-20, 18-47=-20 4) Dead + 0.6 C-C Wind (Pos. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pig Vert: 1-2=95, 2-7=56, 7-13=56, 13-14=48, 25-44=10, 24-25=10, 23-50=10, 21-50=74, 20-21=-10, 18-19=-10, 18-47=-10 Horz: 1-2=-103, 2-7=65, 7-13=65, 13-14=56 5) Dead +0.6 C-C Wind (Pos. Internal) Case 2: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=48, 2-7=56, 7-13=56, 13-14=95, 25-44=-10, 24-25=-10, 23-50=10, 21-50=74, 20-21==-10, 18-19=-10, 18-47=10 Horz: 1-2=-56, 2-7=65, 7-13=65, 13-14=103 6) Dead +0.6 C-C Wind (Neg. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert 1-2=0, 2-7=36, 7-13=36, 13-14=28, 25-44=-20, 24-25=-20, 23-50=-20, 21-50=64, 20-21=20, 18-19=-20, 18-47=20 Horz: 1.2=-14, 2-7=22, 7-13=-22, 13-14=-14 7) Dead +0.6 C-C Wind (Neg. Internal) Case 2: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=28, 2-7=-36, 7-13=36, 13-14=0, 25-44=20, 24-25=-20, 23-50=20, 21-50=64, 20-21 =20,18-119=-20, 18-47=20 Horz: 1-2=14, 2-7=22, 7-13=-22, 13-14=14 8) Dead + 0.6 MWFRS Wind (Pos. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plt) Vert: 1-2=24, 2-7=5, 7-13=21, 13-14=13, 2544=-10, 24-25=-10, 23-50=-10, 21-50=74, 2(1-21=10, 18-19=10, 18-47=-10 Horz: 1-2=33, 2-7=13, 7-13=29, 13-14=21 9) Dead +0.6 MWFRS Wind (Pos. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) rntlq.hmRa,y�lrmmm'H110fa9n(tWffyIXU14IF116t(061M6�(HAm1lal:afxAarbnicryb„PpeWmefrtiMn m,Lml,ep Rmgi[P,dm4brLie�4li ld 4GYmuliue�.Iv mNmmtn.ir YR,ImalxmmOmmrbm now F Mwrh wphg )mKor hp4k f gNO4iq„um„nwm, Jaw eondp PE sxeov tleuaNiautrurl4Yghmn;ry&VtCmMKmPrmxasmlrFlrmielD,Onk*JmvlaAmR.mCWmhlbttgol.edRl bPindtlmmidekY LmimcaSSlmfftLL'Y afl90btlM98IDhmnTSlid N+wb nmm tnGirwAnvGs,sf4 mtrkpregadfwem.leuasylw mrodmPm,tl�lmnnm 'k...tf'fminelMlG.v^m/rmrmm�MVlmlAavaKvmlbr=�Ais lnim5meb,np¢fwtdmnf4i trtlpr LntlnP6p^mrlm�v ltl.e`.4n us, mi,ue xPwe..as,s,e01 fravld tlMrm,evbaeenaahmlaruTa,anei�wrok�aemmsaiwwaa,nu:�rr a N [paurmrhAiR agdicJhnmmlAal�ml. ox: om,srzms J//////��■•�\\\\\\ � u bppytt®1016A i Wdinsses-Anlo r1.Iocbep4 P.E pep ddmior dbitdommem mv�form,ispioh3dedxaEtmne vMeepe�musrooM1om! 1 &dtnsi'e; ImM1oorldomliO,Pi Jot Truss Truss Type cry Ply RENAR MORNINGSIDE A01334+34 WRMSBMB3 A01G Roof Special Structural Gable 1 1 Job Reference o 8onal A-1 Roof Trusses, Fort Plerce, FL 34946, design@altmssAom Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MITek Industries, Inc. Mon Sep 17 11:33:35 2018 Page 2 ID:tW YXbtUG W VXBg9MPyEYwl7zgtLudbfUW uP3RT5ayYK3CvTwpN410AkWnE3oDvBi CyclYk LOAD CASE(S) Standard Except: Uniform Loads (plf) Vert: 1-2=13, 2-7=21, 7-13=5, 13-14=24, 25-44=10, 24-25=-10, 23-50=-10, 21-50=74, 20-21=10, Horz: 1-2=-21, 2-7=-29, 7-13=13. 13-14=33 10) Dead +0.6 MWFRS Wind (Neg. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-9, 2-7=18. 7-13=-1, 13-14=7, 25-44=-20, 24-25=20, 23-50=20, 21-50=64, 20-21=20, 18-19=20, 18-47=-20 Horz: 1-2=-5, 2-7=4, 7-13=13, 13-14=21 11) Dead +0.6 MWFRS Wind (Neg. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Unifoml Loads (plf) Vert: 1-2=7, 2-7=-1, 7-13=18, 13-14=9, 25-44=20, 24-25=20, 23-50=-20, 21-50=64, 20-21=-20, 18-19=20, 1 a-47=-20 Horz: 1-2=21, 2-7=13, 7-13=4, 13-14=5 12) Dead + 0.6 MWFRS Wind (Pas. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pIf) Vert: 1-2=24, 2-7=32, 7-13=17, 13-14=9, 25-44=10, 24-25=10, 2350=-10, 21-50=74, 20-21=110, 18-19=10, 18-47=-10 Horz: 1-2=32, 2-7=41, 7-13=26, 13-14=17 13) Dead + 0.6 MWFRS Wind (Pas. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=9, 2-7=17, 7-13=32, 13-14=24, 25-44=10, 24-25=-10, 2350=-10, 21-50=74, 20-21=10, 18-19=10, 1847=-10 Horz: 1-2=-17, 2-7=26, 7-13=41, 13-14=32 14) Dead + 0.6 MWFRS Wind (Pas. Internal) 3rd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plo Vert: 1-2=24, 2-7=32, 7-13=17, 13-14=9, 25-44=10, 24-25=10, 23-50=-10, 21-50=74, 20-21=10, 18-19=10, 18-47=-10 Horz: 1-2=-32, 2-7=41, 7-13=26, 13-14=17 15) Dead +0.6 MWFRS Wind (Pas. Internal) 4th Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=9, 2-7=17, 7-13=32, 13-14=24, 25-44=10, 24-25=10, 23-50=-10, 21-50=74, 20-21=-10, 18-19=-10, 18-47=-10 Horz: 1-2=-17, 2-7=26, 7-13=41, 13-14=32 16) Dead +0.6 MWFRS Wind (Neg. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plo Vert: 1-2=18, 2-7=10, 7-13=5, 13-14=3, 25-44=-20, 24-25=20, 23-50=-20, 21-50=64, 2D-21=20, 18-19=20, 1847=-20 Horz: 1-2=-32, 2-7=-24, 7-13=9, 13-14=17 17) Dead + 0.6 MWFRS Wind (Neg. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=3, 2-7=-5, 7-13=10, 13-14=18, 25-44=-20, 24-25=20, 23-50=-20, 21-50=64, 20-21=20, 18-19=20, 18-47=-20 Horz: 1-2=-17, 2-7=-9, 7-13=24, 13-14=32 pemp Yxdn,dpnm.mYir�f ln4a(0��j6¢11LNWLrpQ31pl5�ipY}ry-,q_;L4glaaal`h¢Tigfeu�ra,mndndvm feilrta0npeny�RCtltrLlmrL4+h41E1Eem 9elih+rs+. Mu,�durd=YR9a5 ' d.404 Vr4¢d�plurmtrimllhntll,Wa.lno,®.mm�,N.+PtrPd+m�n' iit.+i+dMtrfm le,PAmuNrna Hms wn,lcoe�p NebH tifaPuwM+khdyumvaica.A1 a.meou,nmrE vzam rmdG'stuutruTldLgkmn,PaftiWdY�aLYOmi bvplyeieYMggpnl,DhmWdYH:YRrmrrir'JgW,s2Pk116gpMiYWi pLm,lYlnrttYgtaiY;.RystlO�fnrh¢ip 89gdhQrui9fjd w� tla�racnstel5 YYig6xlp,'remmctAs4dir mrmtlm�mvelmfeUA3nYmagr�y,mtempevevPelpiadhm iaummvtvrLwvWvalrvlsm,m,�pnbOwraaapw Yim.l,mo-,L+:upn+mrwYmd.ai n.v .RNUI nu„ntcdh.tvaamdyadieahvl(vm�n�,.tin wo-,.[a�u[rtYuv.r�w eG,4N.enaemou¢wmveae�nnu.demy w,e vvnsrsole � Opyrgt®10I611 Ye1Tnms-Amwpl.pvmbv N,P.L kpmdvAmalaisdvfvmem,movy luquylvAl'ArQnMvmik vmpvyeimumvhemAI laE7Lvstft»dmdvvyi:ivaholO,Pi Job Truss TmssType Qty PlY RENARMORNINGSIDE WRMSBMB3 A02 Roof Special 4 1 A0133435 Job Reference (optional) r nun:o,us May io4ulornnca.zius Mavin4uiomji 6.00 12 3.6 = 2x4 II 6 7 Inc. Men Jm it il:J9:Jb 2uiu Dead Load Defl. =118 In 3xfi 4 4 4z6 5 3z4 q 8 Us 3z4 4 9 3 11 we 3z4 10 1 1 2 0 21 2a 19 6x8 8 14 1) q N q — 8xe = 32 Y 3x6 = X4 2x4 II 16 15 13 3z6 = 3x6 II 3x8= 3xfi= 1.5x4 II LOADING(psf) SPACING- 2-" CSI. ❑EFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC '0.55 Vert(LL) 0.11 21-24 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.52 Vert(CT) -0.18 21-24 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.66 Horz(CT) 0.02 11 n/a its BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 226 Ib FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP N0.2'Excepta B4,B2: 2x4 SP No.3 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or4-8-13 oc pudins. BOTCHORD Rigid ceiling directly applied or 4-2-7 oc bracing. Except: 1 Row at midpt 6-17 10-0-0 oc bracing: 18-20 WEBS 1 Row at midpt 8-17 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 58510-8-0 (min. 0-1-8) 16 = 166910-3-8 (min. 0-2-0) 11 = 73210-M (min. 0-1-8) Max Horz 2 = -197(LC 13) Max Uplift 2 = -153(LC 12) 16 = -365(LC 12) 11 = -256(LC 13) Max Gmv 2 = 590(LC 23) 16 = 1669(LC 1) 11 = 785(LC 24) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=-084/406, 3-4=290/208, 4-5=56/300, 5-6=461386, 7-8=-40/375, 8-9=-4351409, 9-10=574/406, 10-11=-1130/637 BOTCHORD 2-21=-113/561, 17-18=-2/299, 16-17=-1603/1041, 6-17=637/392, 14-15=-401/948,13-14=-4011948, 11-13=-401/948,4-18=-189/485 BOTCHORD 2-21=-113/561,17-18=-2/299, 16-17=-1603/1041, 6-17=637/392, 14-15=401/948,13-14=-401/948, 11-13=-001/948,4-18=-189/485 WEBS 18-21=99/595, 3-18=-4231451, 4-17=640/464, 8-17=-7267705, 8-15=172/426, 15-17=0/468, 10-15=-580/495,10-13=0/282 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; VUIt=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip OOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 4) •This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 153 Ito uplift at joint 2, 365 to uplift at joint 16 and 256 Ib uplift at joint 11. LOAD CASE(S) Standard rvlq.heela,gllnMm'nt1011Rr56((DIa1,rRiLLIB16t Gk"i®na{IOtl(61n jImCiVp'JfR6eluElhtlpSa,WmdrzirtlaM1lLrub¢4mq�tl@, 41pr11v441itCaem4.MYnu WIUINu ➢vdoi4Rq.gN WretmaAilknfi9G a1mmID144 Y1i iNrB1?IgvuQ 1xd%bF>IOI pJ WN111Wyb6tm!ve�.madmVmlWdl4�m'%n4 Im14m41R1@u{Aa1T+BIm4ID4Wf rbiM 7minl+wergm,H9telml.witri. Jaw BPmIm PEBteW dnllSa lnutrgitlYvlEmn,rc6YTlmMmmOmisr6rc1g1nmlNmlp14T,6netYlhOLLY.aiO,hIGY3{WevdOFL lo4Trt11mI0Be3a&l 1411mtW27WS42V'IefleNotl6v9ddhhnyrvl3�Id xxYxwu [Nneuui0 G91B16 ' m mhrlayvmirmescas4)YY hi0ldmpomiofytl!IvsYm4dpS4gxmYC%S'vmu��mlllamrflevlMr�AilmYplm.iMh9asLml®i Sstbleelpl ihilpr imlm4hlm m1muYN ae.eYu �I6n'u'ene' Rnerte,R91Be6 Iiermlblln44V M��nm9hmil®id,eLOflm,0.v4fgem6liihlxl5mPmrtmaSIRB4Y Em14ih Wq�kumm1Ym141M11. OYa 04152BIB � LppiAM D 70i{A I lvdimsm Jsivgl.ivmtvm,ri Repmlelevviau WmmenS®myfuquptv63Ne{x'YEvan6evMeefelw]dvv6vmA-I kdlnsieS�IvRvvrL.TvoRelarF Job Truss Truss Type Dty Ply RENARMORNINGSIDE �WRIVISBIVIB3 A03 ROOF SPECIAL 2 A0133436 Job Reference (optional) H-1 Hom i ruses, ron rierce, rL araab, cesigntmanruss.com Hun: u.ziu s May 6.00 12 516 = 18 2018 MiTek Industries, Inc. Mon Sep 17 l l:33:36 2018 Pagel 3x6= ex°— 15 14 13 11 3x6= 1.5x4 II 6x8 = 3x6 = 3x4 II 1.5m II Dead Load Deft. =1/4 in a0 '4 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (too) I/deb L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.64 Vert(L-) 0.2218-24 >999 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.99 Vert(CT) -0.4416-18 >999 240 BCLL 0.0 • Rep Stress Ina YES WB 0.78 HOR(CT) 0.13 9 n/a We BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Wetght:20811b FT= 10% LUMBER - TOP CHORD 2x4 SP M 30 •Except• T3: 2x4 SP No.2 BOT CHORD 2x4 SP N0.2 `Except* B4: 2x4 SP No.3 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-7-9 cc pudins. BOT CHORD Rigid ceiling directly applied or 2-2-0 cc bracing. Except: 1 Row at midpt 5-16 10-0-0 cc bracing: 14-16 WEBS 1 Row at midpt 6-16, 3-16 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 9 = 148710-8-0 (min. 0-1-12) 2 = 1487/0-M (min. 0-1-12) Max Horz 2 = -197(LC 13) Max Uplift 9 = -381(LC 13) 2 = -357(LC 12) Max Grav 9 = 1487(LC 1) 2 = 1487(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-2612/1590, 34=-1824/1223, 4-5=-170611241, 5-6=1784/1255, 6-7=-2002/1427, 7-8=2142/1424, 8-9=-2678/1651 BOTCHORD 2-18=113712261, 17-18=-1137/2261. 16-17=1137/2261, 12-13=131012333, 11 -1 2=1 310/2333, 9-11=-1310/2333, 5-16=-711/1145 WEBS 8-13=562/482, 8-11=0/272, WEBS 8-13=562/482, 8-11=0/272, 13-16=868/1806, 6-16=488/484, 3-16=-8391704, 3-18=0/397 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 381 lb uplift at joint 9 and 3571b uplift at joint 2. LOAD CASE(S) Standard em4im e..prmwo-uu5ctnnu(ways¢ueree.mua�mmmmslartoywet+oaxmr+nsoa,mow=awd.d.en.muwo.wvwntmo-eawLkaRitAd.ms,ak5n.�. mu„mw,myemmo. } I Wrew.artewu,wmo-mswraa.H 1 rm4Wo-xp+ymdha�c4esm nrm�mwm&pmao-ra.omd.pymp„nad^vro-axwsaaewFr,.nttmnamoM a.tw ur�*.wpawk`3wueenuurW u,.ea.�w resxaos tlwdV NutvmreYvyxffimr JaryahoartbPndi.Amtly�vmraXq Otl�..hmmau0[lC�Iw MllzYgmtlnH&yp�ahmululevwabrux.tLSgtrloymyeeNmdstlq dffimee>fauiryd � ��baenroc�s�ais 8WLi�+pvdfevi�nebsLwx6lCLdtiPm9rmlWtloJaG�4JEA r?{aYRLi:smrfN.la6lnldiWlmiJuciE6�mtll�.filC9rssb+M�b'�+ss3tle6YUw A!R..L,ubi44pmetlrm�Omfineatii RP+Re,Rarsu r:xaxla..uhvusamav���4hemmwa,:imtmsWTrgm„pmm7xwreuym,.tiwf�.4+.amavAa �•'B�rmnmlmomr. D.oaovzma • 6ppigAr0 p0IN lPvdinuei-lcasryp.iomheN, I.L IepmduQavdW6doiomevl;mmrlmeEu�oGEileQriWpn MerutlseyeemuwehooAlHeA7nsasAeRvv7i:7emFolll,pE Job Truss Truss Type Oy PlY WRMSBMB3 A04 Roof Special �RENARMORNINGSIDE A0133437 Job Reference (optional) A-1 Rcxur Trusses, Fort Pierce, FL 3494b, aeslgn(dal truss.com i Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek 6.00 F12 6x6 = Inc. Mon Sep 1711:33:36 2018 Page 1 Dead Load Deft. = 5116 in 1.Sx4 O 3x6 G 3x4G�W5 II 4zfi45 8 3x4 C 9 W7 7z10 — 17 16 24 15 14 3x4=3x6= 4r8 2x411 12 1.5z4 II 3.00112 48 9-1-4 17-8-0 23-0-6 29-1-12 38-0-0 9-1-4 8812 6-1-6 8-10-0 Plate Offsets (X.YI-- [6:0-2-0 0-1-121 [8:0-3-0Edgel. [10:0-1-14 Edgel [13.0-4-4 0-3-81 LOADING(psf) SPACING- 2-0-0 CS]. DEFL. in (loc) 1/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.83 Vert(LL) 0.42 12-13 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.93 Vert(CT) -0.78 12-13 >588 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.64 Horz(CT) 0.39 10 We n/a BCDL 10.0 Code FBC2017/rP12014 Matrix -MS Weight: 2081b FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 *Except* T1: 2x4 SP M 30 BOTCHORD 2x4 SP No.2 *Except* B3: 2x4 SP No.3, 84: 2x4 SP M 30 WEBS 2x4 SP No.3 *Except* W5: 2x4 SP No.2 WEDGE Right: 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-2-0 oc pudins. BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 4-15. 6-15. 6-13 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (Ib/size) 2 = 1482/0-8-0 (min.0-1-12) 10 = 148210-M (min.0-1-11) Max Hom 2 = -197(LC 13) Max Uplift 2 = -360(LC 12) 10 = -383(LC 13) Max Grav 2 = 1482(LC 1) 10 = 1482(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=-2646/1667, 3-4=2447/1598, 45=-1766/1252, 5-6=1691/1272, 6-7=-3621/2344, 7-8=3574/2163, 8-9=-3672/2142, 9-10=-4588/2708 BOTCHORD 2-17=1237/2327, 16-17=-903/1933, 16-24=903/1933, 15-24=-903/1933, 7-13=-302/396, 12-13=-2287/4129, BOTCHORD 2-17=-1237/2327, 16-17=-903/1933, 16-24=-903/1933, 15-24=-903/1933, 7-13=302/396, 12-13=-2287/4129, 10-12=-2290/4132 WEBS 3-17=308/382, 4-17=233/505, 4-15=-611/558, 13-15=-537/1602, 6-13=154312694. 9-13=-83Of/30, 9-12=0/303 NOTES- 1) Unbalanced roof live loads have been considered for this design. - 2) Wind: ASCE 7.10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 4) *This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 1 O.Opsf. 5) Bearing at joint(s) 10 considers parallel to grain value using ANSUTPI 1 angle to grain formula. Building designer should verify rapacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 360 lb uplift at joint and 383 lb uplift at joint 10. LOAD CASE(S) Standard srvpn,mamryrmwbwianrresa(uurPjmiiltruivama�ammztimryammicaarr�imryaamr,,.,imm„tam.mtmutmcda.Pll�mbbrtua,4itWmx,aiVn,n. mtis,m and am:.y Wutmmrrn+�hwkblflmNa4 a.t mlmptrpf P,.LmtlnW*mEkmJ erRampmm,mm¢p,dmm4mmfy �:qn+wnk,tmapibs.kmmbwnauomt.artht tmm�vaw�u3�wdo�.nc1 .�ma,.w Pe cxem edaslktkuknlldBinmrt�ry3WtlbMm.bdmisr&Ndptxmltl[dluyvJknCNda rdae ma Ydlrxnm,edP.t NmpndtlbiY]mwfm rim Wtes'elam3gm,p WmBlmhvt YShmmpt;dh( wrc. Nwvn P+4imart+ewm6i5 ustfl�aM, ' ba+�dgRurmalrufam. ramti,mM alrOmbPtlalmiptlYnntlmCae!!(vismYgtiaxs',�pdJnitl6lil1m911ad,mlhpvtl AtlmmIMalai&,ryr,+lMse16ai64Lm kupr.lm,pnpfipacvJl Y�nrGdai - RPWu.Rmm4 sp J9s xdtph Pam ktliai rAYYbW+maN,si a mn6 4 m,y31�x'cm Lnlro1RL� pudvldrdMsaam h� a 'h,tlrcLhlnu xmaldlb yp [q mr ap om: Ov�YNte • [vppipd107616Alfedinssn-,iddogl.ivmlv6l.l.L repadotliorofabtomcnm ma/IorgisjioL3irtdkuhom@e mrib,pnmi'swahvmll&aliiessei Inhwli iomkem, lJ. Job Truss Truss Type Dry MORNINGSIDE A01334$8 WRMSBMB3 A05 �Ply Roof Special 9 1 �RENAR Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946. design@altruss.com 6.00 12 Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 5x8 = Inc. Man Sao 17 11:33:37 2018 48 4x8 8-2-1 1354 16-0-0 V-15-0 22-11.4 28-9-5 38-0-0 8-2-1 F 53-3 12-10-121 5-1-0 1� s-z-11 Dead Load Dart. = 91161n Plate Offsets (K Y)— f2:0-1-14 Edgel f4:0-3-0Edgel, f8:0-3-0 Edgel f10:0-1-14 Edael LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Lld PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.79 Vert(LL) 0.55 12-14 >833 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.94 Vert(CT) -1.03 15-17 >443 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.77 Hom(CT) 0.66 10 n/a We BCDL 10.0 Code FBC2017[rP12014 Matrix -MS Weight: 219lb FT=10% LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30'Except' B3: 2x4 SP No.2, F2: 2x4 SP No.3 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-2-0 oc pudins. BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, In accordance with Stabilizer Installation guide. REACTIONS. (fib/size) 2 = 1482/0-8-0 (min.0-1-11) 10 = 148210-8-0 (min.0-1-11) Max Horz 2 = -197(LC 13) Max Uplift 2 = -360(LC 12) 10 = -382(LC 13) Max Gran, 2 = 1482(LC 1) 10 = 1482(LC 1) FORCES. (III) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4727/2872, 3-4=-441212421, 4-5=-4348/2437, 5-6=-349111945, 6-7=3449/2077, 7-8=-425612573, 8-9=4320/2558, 9-10=-4693/2889 BOTCHORD 2-17=-2406/4271, 16-17=-1831/3792, 15-16=-181713815, 14-15=-914/2610, 13-14=-1800/3598, 12-13=1816/3577, 10-12=-2488/4243 WEBS 6-15=905/2008, 6-14=-710/937, WEBS 6-15=905/2008, 6-14=-710/937, 7-14=643/667, 7-12=288/595, 9-12=334/496, 5-15=718l704, 5-17=73/521. 3-17=-306/555 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C.Extedor(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are 1.5x4 MT20 unless otherwise Indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 2, 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 360lb uplift at joint 2 and 382 lb uplift at joint 10. LOAD CASE(S) Standard rmay iiwmrr�lrm;hm�•urwrr�a(ururfaesuleiurwm¢armimri'ans7l.mesa,earrm iomamPl�rdml.remmmlmomva,+.gtmvidm+�rt maRriun�wnm.,m. titikmwaedkk,lce;mr ' WrellovoWlMuss@4mimmlTiPkdlblLuhq,IN+^W.Wmf a7s�4&,C nrsam rcmepmamr�mdq.em!}*lammmkw+im*d.txsbmuummoWrwnP.mtl�enapmyY4wmmxasY .ta�ea,�wreusm dm,d�7�mimmlk�ikmiuraPtgbmmkym O.vlirhedg4rmmcgR�m.4,C'dYmmWm(mim MkmndekeOLL Mpprm,lb)Wiia[eBwamlmsl�'1YiII'{m@.6,sA6uAkdy d,44m¢gaps➢9i. �,q���sOGSiets bNyle¢mtl{®�Nsk•EMImRiUdmPmululYm�r'dmktlmlaysaSGrL'n'e�Ju�PgdNbUd�m�tlumlmlmYP�mlYvt4,�dSeuelpti/yLef Mnp Art�lniy4}mmllanPSEbarw�dl p,ry a. Ft s,us ❑eukgtidh I.Bmmdrai!ie,lhxrvk�lvlrtL.rotwW7(9'+=6rme.tr'Wkgrvfausrm.rgav[nkE€a Nwvlv4eev,mxxlkmr. ocx aensrmly � (vppi➢hIDP0113Itviliresses�Am6v pi.ivmSvAl,Pi tepmdvdim AlEudvmmevl,®mplmvykpivh3AeAiudpmlty xriOevje®sowhmmkl GNrigie; AcAvpt.phAo111,4E Job Truss Truss Type CityPIY RENARMORNINGSIDE WRMSSM133 A09 Hip 1 A0133439 Job Reference (optional) N-i Rcor i russes, ran rierce, rL ansno, cesign(daiiruss.com r Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Mon Sep 1711:33:38 2018 Page 1 ID:tWYXbtUGW VXBg9MPyEYwl7zgtLu-2ALdDLxHMMrfRQHvkKSAYS7cjEBuj3yWUB7reXyclYh 6.00 12 Sx8 II 5z6 = Dead Load Detl. =12 in 48 a.uul r[ 16 1514 3z4= 3x6= 4.6 = 2.4 It 6.6 = 3x4 = LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (roc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.76 Vert(L-) -0.53 12-14 >855 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.91 Vert(CT) -1.02 12-14 >448 240 BCLL 0.0 Rep Stress Incr YES WB 0.98 Horz(CT) 0.59 10 We n/a BCDL 10.0 Code FBC2017/rP12014 Matrix -MS Weight: 228 Ib FT = 10% LUMBER - TOP CHORD 2x4 SP N0.2 *Except* Tt: 2x4 SP M 30 BOTCHORD 2x4 SP M 30 •Except• B2: 2x4 SP No.3, B3: 2x4 SP No.2 WEBS 2x4 SP No.3 *Except* W4: 2x4 SP M 30, W3: 2x4 SP No.2 WEDGE Left: 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-5-7 oc puffins. BOTCHORD Rigid ceiling directly applied or 4-10-10 oc bracing. WEBS 1 Row at midpt 8-14 2 Rows at 113 pis 6-15 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 14821041-0 (min. 0-1-11) 10 = 148210-8-0 (min.0-1-12) Max Hom 2 = -192(LC 13) Max Uplift 2 = -356(LC 12) 10 = -079(LC 13) Max Grav 2 = 1482(LC 1) 10 = 1482(LC 1) FORCES. (lb) Max. CompdMax. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=-4672/2642, 3-4=-3755/2053, 4-5=-3623/2066, 5-6=-3658/2231, 6-7=-1356/1155, 7-8=-1605/1195, 8-9=-2405/1531, 9-10=-2711/1754 BOTCHORD 2-18=-2157/4213, 17-18=2167/4227, 5-17=-326/425, 14-15=-477/1356, 13-14=95311868, 13-25=-953/1868, BOTCHORD 2-18=-2157/4213, 17-18=-2167/4227, 5-17=-326/425, 14-15=-477/1356, 13-14=953/1868, 13-25=-953/1868, 25-26=-95311868,12-26=-953/1868, 10-12=1437/2400 WEBS 3-18=01273, 3-17=8611764, 6-17=-203814513, 6-15=24751782, 15-17=-107113096. 8-14=-720/659, 8-1 2=1 73/560, 9-12=-385/482, 7-14=-233/467 NOTES. 1) Unbalanced roof live loads have been considered forthis design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpl=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcumenl with any other live loads. 5) t This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/rPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 356 lb uplift at joint and 379 lb uplift at joint 10. LOAD CASE(S) Standard fMi M1¢etaryNPP�..d'mllf4fird5aa[$IFS,®:YL®16t(011i16a0{tOtl(pdJ'11�,f,6`.,tfml'dt4ehbmTW^�PtlrelNnPb lrtulugXvegll[ijtlbltlaxr.i<44r1Wvcm9Mkn vCW,rfe.hrb'd bIDA.cij I WIe4a9nkbfbpbrt,fbbP.9Pp,A111ff1,RIh9p IryCNQ1.1rJe'llaxAj mf Ptl PIiDJPPlPd RPY,Nlf mdpmwvirgPu.11P9stOprbd W4ltlbfi�.e1„f1LydNWblOUltlltl 1n1.NrAjfeusppµ¢�tlC6prs,5:lRi1. JeMepnlp PE6tBCB d,um4{I,uvtu11k0ircb,egzCmmdMu4dOmi,rAeCtleFmhbld494es¢xt.dMamd BGNC.ol6efuml�Neel Il4LM1pP,Kdd�Odm&J ntlO, Inrt4Y.9x�+iRW.P�.II�P1treYydAYhnga�tihf vnvienouwe+.4meaxq G9es,s dWldlie(m¢rev'mcIDWSY'NPdI[OddP.,mialPdmmdb4Ylxurns�mlt4s�u:1�f&uFNhiPltlBembbevltii�P'6e•-1M1lefaebe,Vmtln,dM.e641wb!W 1mh 4bFanmllmtYM.eaa,sE¢ u5�5,lutle&w. rxmdda dh emmmmw5i�'wharvP�dm d:Iuim, hredr' m•x4 gfA6} v nr+=m,ns.vw � dwfq.m urae+r ub,s1 h.m m aaitnee mmamPfit.. mx:: aensrm,v Gppitm®ShcEdlledinssn-Am1ag1.1vmEeiO,Pl IepvdvEivvahlicdomgm,maglo,�is�ivE3ihAiokvt@e nNeepnmiecov5vmlliealinsus, AmLvvyl.rvvlom,Pi Job Truss Truss Type Oty PIY RENKR— O INGSIDE A01334'40 WRMSBM83 A10 Hip 1 1 Job Reference o 8onal A-1 Roof Trusses, Fort Pierce, FL 34946, design@a1truss.com 6.00 12 Run: 8.210 s May 18 2018 Print: 8.210 s Mav 18 2018 MiTek 500 MT20118; 54 = 11.33:38 Dead Load Defl. = 7116 in 3x4 i 4 5 3xd 1.5x4 J 8 B 1 5x12 —• 0 1 2 17 3 0 1.5x4 11 12 84 9 r� 0 q 9 4x8 3.0012 14 15 73 17 3x6= 2x4 II 34 — 1.5x4 II 4x10= 1112 26-1 38-0-0 781 I 4) 7470&6 - -7-0 I2 9-1-0 Plate Offsets (X Y}- 12:0-1-14 Edgel f4:0-3-0Edmel f6:0-6-0,0-2-81 (7:0-3-0 Edoel 116:0-5-12 0-2-121 LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.95 Vert(LL) -0.41 16-17 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.96 Vert(CT) -0.8216-17 >558 240 MT20HS 187/143 BCLL 0.0 ' Rep Stress Incr YES WB 0.93 Horz(CT) 0.46 9 n/a n/a BCDL 10.0 Code FBC2017/rP12014 Matrix -MS Weight: 2101b FT = 10% LUMBER - TOP CHORD 2x4 SP M 30.'Except T3: 2x4 SP No.2 BOT CHORD 2x4 SP N0.2 *Except* Bt: 2x4 SP M 30, B3: 2x4 SP No.3 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied. BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. Except: 10-0-0 oc bracing: 14-16 WEBS 1 Row at midpt 6-13, 8-13 JOINTS 1 Brace at Jt(s): 18 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1484/0-8-0 (min. 0-1-11) 9 = 148310-M (min.0-1-12) Max Horz 2 = -177(LC 13) Max Uplift 2 = -340(LC 12) 9 = -066(LC 13) Max Grav 2 = 1484(LC 1) 9 = 1483(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-4690/2609, 3-4=3730/1954, 4-5=-3641/1979, 5-6=-3199/1834, 6-7=-169111224, 7-8=180911205, 8-9=-2596/1582 BOTCHORD 2-17=2128/4231, 16-17=2138/4245, 12-13=-1223/2246, 11-12=-1223/2246, 9-11 =-1 223/2246, 5-16=-55211264 BOTCHORD 2-17=-2128/4231, 16-17=2138/4245, 12-13=1223/2246, 11-12=-1223/2246, 9-11=-122312246, 5-16=-552/1264 WEBS 3-17=0/274, 3-16=-896/828, 16-18=79112099, 6-18=-793/2103, 6-13=-822/276,13-16=-776/2009; 8-13=8331718, 8-11=0/383 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf, h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 6)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7)Bearing at joint(s) 2 considers parallel to grain value using ANSIrrPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 340lb uplift at joint 2 and 366 lb uplift at joint 9.- LOAD CASE(S) Standard wmgra,um"�rmwm•a•t4drmxw[vsa1[ssiamsemrtmusrmruir(crtaye.uenmauraa sJhm�gm.�m,onoaml*a,asv�at!i9dm+,s.�ru:xlCih�es�xm.,.: r�n,d� dea mmmry MRv4nmamYn9dY a1mp10dnkvrik Lmlmp s>•�„aN! 9^a�l6ssr}�5d4arN0ePv%+isvamPnaARi�#relvgwrrrg 9z0LgS.mlegeOmWernaHV9aM10Uu4�sll4lTeEK�mspmk4dafm0uv6woYW.}. Ja�eamim PEexeas �OtlaS)54k`WMYvghmm(bN$IEeml[4hMw�i.fi'vY�R1 �AYaiO�^Rkm�tlNdm QfhMl&GNhiITS°4vtifil64}rgiddm6�WwnYeUdmiWi,Ol YQ6cehR'4e fi{690baf}�/3flShtlM1�S%d; M�51 °yytv5e 0�6 onnGG9�6,6 I mauyr�eumU.Jn«Mwr.msmmmw>�odyudgrtmgeem�Srncc,ea.w+r+�:Kymmuooeme�ams�P�"nu�,�g��w#+>•+apurs oww.,Brd,.pn�.QeemuxmwvMFd xr,m.a�.ere ra,iui�ak.rl�aeam9msdvhmr�Jkm�LiiEm a,�r�eramuuuam srtaar�smdsar mamo�e�v.macdnmc o,�,��sa�,a try}T9d�®POIdA7PeefLesses-Xmdovri.iomdalltpi bpietcdjmaifdudomvea vngvyloio�up�odThp®�polMexnthvpe�misvnhomklYaaipEsus Atihooyl. iem1611[pi Job Truss Truss Type Qty WRMSBM83 A11 Hip �PIY 1 1 �RENARMORNINGSIDE A0133441 Jab Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, deslgn(lDaltnuss.com 8.210 s May 18 2018 MiTek Industries, Inc. Mon Sep 1713:26:13 2018 Page 1 ID:tWYXbtUGW VXBg9MPyEYwl7zgtLu-Ij1Hy6gSYrvCLWAAyVBEpyHwfDc6wAxnodxnEVycjv8 tsdw 1 616d 130-0 147.6 18-a11 22il 29314 W— 39bo r1n a-t64 I at-12 1-]-6H 3511 I a1a5 ~ all-1d a&2 tip 0410 6.00 12 5xlo= 21411 5x1O= 2x411 6x8= 1.5x411 15-a0 aia4 13-1.8 14-] 22d 29316 3e-a0 al od aid 11-a14 ]-FO I all-16 I BA-2 a 10 Dead Load Dell. = 3181n Plate Offsets (X Y)-- 12:0-1-14 Edgel 13:0-3-0 0-3-01 I6:0-8-0 0-2-81 17:0-3-0Edgel 112:0-2-00-3-41 114:0-2-8 0-3-01 115:0-4-0 0-2-81 LOADING(psf) SPACING- 2-" CST. DEFL. in (loc) I/deg Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.98 Vert(LL) -0.41 15-16 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.92 Vert(CT) -0.78 15-16 >584 240 MT20HS 1871143 BCLL 0.0 Rep Stress Incr YES WB 0.88 Horz(CT) 0.45 9 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 211 Ib FT =10% LUMBER - TOP CHORD 2x4 SP M 30'Except' T3,T4: 2x4 SP No.2 BOT CHORD 2x4 SP N0.2 *Except' B1: 2x4 SP M 30, B3: 2x4 SP No.3 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied. BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 12-14.6-14.8-12 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1482/0-8-0 (min. 0-1-11) 9 = 1482/0-8-0 (min. 0-1-12) Max Horz 2 = -162(LC 13) Max Uplift 2 = -325(LC 12) 9 = -353(LC 13) Max Grav 2 = 1482(LC 1) 9 = 1482(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=4658/2567, 34=3996/2133, 4-5=3706/2115, 5-6=3717/2133, 6-7=1834/1285, 7-8=-1937/1261, 8-9=-2598/1569 BOTCHORD 2-16=209414201, 15-16=2114/4223, 11-12=-1211/2247, 9-11=1211/2247, 5-14=354/294, 14-15=-1440/3506 WEBS 3-15=617/623, 4-15=542/1205, WEBS 3-15=-617/623, 4-15=-542/1205, 12-14=792/1875, 6-14=-997/2299, 6-12=-477/190, 4-14=-283/581, 8-12=705/612, 8-11=01336 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise Indicated. 5) This trusshas been designed for a 10.0 last bottom chord live load nonconcument with any other live loads. 6)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 2 considers parallel to grain value using ANSIrrPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=325. 9=353. LOAD CASE(S) Standard taYq�!laz4a,vr+Ymh.b•41 Nmmm(1wa1®'3LLtunt(ommtnrmibrwta7tmGRnulrrnm ed[6,plvoa,didms.mtmrla@aagN'4;dbre.yt.t�4rl mrcu,Rnb+nu me,ma.u, mtlneeme.aj Wletmv�IhsJilbmtlbh199YYNx.A„im,InphpmwpY.j.th4JY�tiutle�lA4npmne®padbpb,Yetlyunln4^tl'nlebl,sp6b,e7,innlgmNo6144ej.tleAI. L,Inpwyl:,nhEgm]¢ay,cLNq .ianmB Ouu�aE 53BOs dM1dG5IM4(fa11Y'G91,bNW9JUChOW,.hON/4dFN1c�Bbllelh{4pC^.YhO]O601Y1.5,SdN4'sl{sri1f11,P111n Ta�N�lf R9d,wFe110dC, INLY9991ffiL4®gg6N:'ibdk916>A�hn,P+4liuld WTaie lbYb 6iGlreainY W31615 ��6iwG aW. h MYgln@nd(u,oY.Nex,dYtYbII0db1'�Ialpi,loe4,l0,PJfi�fm{anYeplhnaYlm'?WluklgtedlVJmMuemlfv@W@6m 1MY5mYeegmilm,4dhm64Ln,Aup.lm,hupOp,eellm,ISM,4.�, RPbv. R.t.ptB i mtlm x'@nh Woa uu@Fgam 91e�r.elm5p a N at Aeonmminmt ,fa.W ldul{.tCN Y tl mNrt NL,u 610tb1aM I@eEgme af�'a0. q ome: oalsav,9 � (vpplitM®7p16A41vv11nsses-AvlEmpt.iv@Iv Ig LL lepmdv4iudllisAvnvem,mvgln,v,itp�oltlueExilhvd W amlevperminivvhvm411edimses�AtlEvvp7.lvvlo N,li Job Truss Truss Type Oty Ply MORNINGSIDE A0133442 WRMSBMB3 Al2 Hip 1 1 �RENAR Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946. design@altruss.com 11:33:40 2018 5xia> Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2x4 II 46 = 5x6 = Dead Load Defl. = 3181n .,,•,� im �a azn= um= 2x4 It 6x8 = 3z8 = it-1-8 14-7-10 1 19-5-13 28-10-14 38-0-0 it-1-8 382 10 4-69 9S1 9-1-2 Plate Offsets (X,Y)— 12:0-1-14,Edge1 f7:0-3-0.0-2-01 18:0-3-O,Edeel f14:0-4-0,0-1-81 [16:0-2-8 Edoel, 117:0-3-0 0-3-3] LOADING(psf) SPACING- 2-M CS1. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.99 Vert(L-) -0.47 12-14 >973 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.26 BC 0.96 Vert(CT) -0.8512-14 >538 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.95 Horz(CT) 0.47 10 n/a n/a BCDL 10.0 Code FBC2017/rP12014 Matrix -MS Weight: 209 Ib FT = 10% LUMBER - TOP CHORD 2x4 SP N0.2 *Except* T1: 2x4 SP M 30 BOT CHORD 2x4 SP No.2 *Except* Bt: 2x4 SP M 30, B3: 2x4 SP No.3 WEBS 2x4 SP No.3 `Except* W4: 2x4 SP No.2 WEDGE Left: 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpl 6-14 MTek recemmends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 148210-8-0 (min.0-1-11) 10 = 148210-8-0 (min. 0-1-12) Max Horz 2 = -147(LC 13) Max Uplift 2 = -307(LC 12) 10 = -337(LC 13) Max Grav 2 = 1482(LC 1) 10 = 1482(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=4661/2664, 3A=4221/2231, 4-5=-4304/2417, 5-6=-4286/2412, 6-7=1957/1362, 7-8=2362/1564, 8-9=-2458/1547, 9-10=-2677/1656 BOT CHORD 2-17=-2189/4220, 16-17=-1586/3735, 13-14=-818/1782,13-24=818/1782, 24-25=-81811782, 12-25=-818/1782, 10-12=1336/2362 WEBS 3-17=-372/548, 4-17=-476/1172, WEBS 3-17=372/548, 4-17=476/1172, 4-16=-042/833, 6-14=1659/868, 14-16=112112493, 6-16>1215/2693, 7-14=1371453. 7-12=349/629, 9-12=-391/501 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load noncencurrent with any other live loads. 5) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Bearing at joint(s) 2 censiders parallel to grain value using ANSI/rPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 307lb uplift at joint 2 and 337 lb uplift at joint 10. LOAD CASE(S) Standard 9e,1�'ryyp^„allrpryBb'tIbN1�4T((tOfPyEeliL®ftftlV®tl{KIWI(nfe'JU➢ONpSM`b¢S¢phY�rsm6i,drtitlnBEuinuBnpFamf{fWjdrl�lled,O,lEbrur9NlCnm. rin ,te�Ix4NerID9; } I yR,lamNmlassil44Wbp6Rv¢bNE466vrmpfq.uN.Ymh6g:xdybWBB1>DtBI++^^OmitaiibptlrtV¢dgYLLbd^PNYryffib4upk4q,rnslpUtivbippA(d RN. rinye v�stbSgvtlem,gM�.i JmntB4m6>p PE6Ml9 d6L46.Mp^u4 I Ygkb � imebw,bd.m'(drN6;y¢mrd¢rp^imx 4,maxdg4Cdrbdb`lrr^rdVn 4pi^�ir1E'!d hl,uCriNtYYupt-C_'p6t'yl.YbAprBlhNgi1844Rq¢,bih6 m�e6W=^6M6i6anG W916,5 >y4xiao�dremtu¢a.,mw.rmommrmddwu'+Bnrw4r�4'm(�?I®`e�?4lndswmroboxrrm+w+=¢mien:,rnw�dgwmadieptmuw¢t�ns?4i^:'2^?mswvmm^,m a'n a,n��i6'a ' si^.bf{dh6esmy¢+v¢x+mdahmrmr,�m�a�nela^4,yrm�^prm4tt'WrgmBircssrow6*¢em6�dms uwi4arm.,BtrmciM. mme astivm,e Lprri'M®7016kI1vdTrvsses-AmhavYiaomdelll,/1 bpmdvAe6oitlisdvmo6m,mtvyfam bpaG3gedrYhaNM6 Bnve6peimiishvhemAlfv61/inuq�IWveri.Tavdom,PE TrussOty Pry RENARMORNINGSIDE AO133443 MSBMB3 F A13 1 1 _:::::Hip Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altiuss.com 5x8 = Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MTek Industries, Inc. 3x4 II 4x10 = 3.6 = SA = 2x411 5x6= 5x10= 9-0-0 9- -8 14-7-6 1 -0 18-5-14 26-0-0 38-0-0 9-0-0 0. -8 s-s-14 6 10 3-5-14 7-10-2 11-8-0 11:33:4U 2U1a Dead Load Defl. = 3181n Plate Offsets (X Y)- [2:0-1-14 Edcel [4:0-6-0 0-2-81 [6:0-4-12 0-2-01 [8:0-3-00-2-01 [10:0-8-4 0-0-141 [12:04-8 0-3-01 [15'0-3-0 Edeel [16:0-3-00-3-41 ' LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.84 Vert(LL) OAS 15 >946 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.82 Vert(CT) -0.8815-16 >520 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.74 HOrz(CT) 0.44 10 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 2041b FT - 10% LUMBER - TOP CHORD 2x4 SP M 30'Except' 'T4,T3: 2x4 SP No.2 BOT CHORD 2x4 SP M 30'Except' B3: 2x4 SP No.3 WEBS 2x4 SP No.3 *Except' W5,W4: 2x4 SP No.2 WEDGE Left: 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 4-10-10 oc bracing. WEBS 1 Row at midpt 6-13, 6-12 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1482/0-8-0 (min.0-1-11) 10 = 1482/0-8-0 (min.0-1-12) Max Horz 2 =-133(LC13) Max Uplift 2 =-296(LC 9) 10 =-319(LC 13) Max Gmv 2 = 1482(LC 1) 10 = 1482(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=4614/2580, 3-4=4407/2338, 4-5=-5132/2862, 5-6=-5053/2816, 6-7=-1976/1323, 7-8=-197611323, 8-9=-2295/1376, 9-10=-2698/1704 BOTCHORD 2-16=2118/4160, 15-16=-1743/3924, 13-23=112012312, 12-23=112012312, 10-12=1394/2399 WEBS 4-15=-76311426,13-15=-1486/3082. WEBS 4-15=-763/1426,13-15=-1486/3082, 6-15=-1534/3288, 6-13=-1979/1063, 6-12=-550/276, 8-12=2421658, 4-16=-457/1130, 3-16=-1581329, 9-12=-454/524 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load noncencument with any other live loads. 5)*This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 1 O.Opsf. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verity capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 296 Ib uplift at joint 2 and 319 lb uplift at joint 10. LOAD CASE(S) Standard rm.minm[mrr'hmb.m•ul'>ollcrw�iwassminunr.+aetmslawia^a3unonveaarcm iedavar+dim mm.l�o[rm+a,.alrtsjdm8anl fma,Rittenmsmm.,re. er�[r .moaJeb>W,nk 4Rhmvv Ikbil9MrslmmlWW§[di 4olirt[h+y h4?rsP 9[adAf haJ MN>Mbm�cmi�mvgkFdnMi4+K'9yrs9mEmtkO[4s�ntlb sva, NssHmJvblGHl ebllf) Ml eveW3 vi vlvd994. .ianm vee 9 mivd4si mvlkl9ntlrtpatlAlh9v2h0�(.t-¢d�i4. mldGtOm➢n. Pe�01G6CbRa(bi3kirRAevilM ThgpnldbN9vlwNl Pdhinit��in'4tm5AfitlN3yY96tlrtga�6i%d' u�Hsl gLme a�we916t5 ImGk90e5a'rd(<ohtor 111ak[WMICeRNW1LPY¢1NYtlhYRW�kitWa'�el,�mrmv@$.Pm !!r(Pd1On[dm�¢Ii RmUPA¢II'tY5vbmpmdiui�4bYb1 4ilVv.LmEei�.feinnNlnLLrcNme.¢kv Rama. 019 [SeVVivi£vdhmLds4ryHgv6�kvlivia`v�nl-1bim6L96i [KIGI46VprGyd 1nrz5�TevEy drolb3my a[g8citvb mfF ibR{L Om. oen52919 A! [oppiglrt®7AIDIlnotirenes-Mdee(J.femha lq P.LlepmluSnAl6alommpm,mvyfmm, zpmbttimE aham%e nNmepewTivvehem Al W&iresu`z AOMe�I:Tcmlem;P.E Job Truss Truss Type Dry Ply MORNINGSIDE WRMSBMB3 A14G Hip Girder 1 1 �RENAR A013344"4 Job Reference (optional) .. 1 Roue nurses, run Pierce, FL 34546, DesignLaluuss.cem Run: mz1u s May 182u18 PnnC 8.210 s May 18 2018 MiTek Industries, Inc. Mon SeD 17 11:33:412018 5x6 = Dead Load Deli. = 3/16 in 6.0012 l y4 :4425 __ 35— 5A 75x6= 1.5x4 4 8 2 76 28 27 4 W y[ 1 6x8 0 6x8 —' 9 10Iq 91 3x8 a 3.00 ri2 74 13 11 0 11 Us3x8 = 12 Us = 3x6 = 3x6 = 7-18 -0 13-54 147115I -0-7-1 384)-0 2 13 3 94-078 Plate Offsets (X V)— I2:0-0-10 Edoel f3:0-3-00-2-71 (6:0-3-0 0-3-01 i7'0-3-0 0-2-01 r15:0.2-8 Edgel f16:0-3-0 0.1-121 LOADING (psf) SPACING- 2-0-0 CSI. in (loc) Udell Ltd PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.69 -0.1911-13 >999 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.99 FH) -0.3911-13 >747 240 BCLL 0.0 Rep Stress Incr NO WB 0.74 0.09 9 n/a nla BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight:196lb FT=10% LUMBER - TOP CHORD 2x4 SP N0.2 `Except' T2: 2x4 SP M 30 BOTCHORD 2x4 SP N0.2 `Except` B3: 2x4 SP No.3, B5: 2x4 SP M 30 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 3-6-11 oc pudins. BOTCHORD Rigid ceiling directly applied or 338 oc bracing. WEBS 1 Row at midpt 3-15 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 766/0-8-0 (min. 0-1-8) 14 = 2405/0-3-1 (min. 0-2-13) 9 = 889/0-8-0 (min. 0-1-8) Max Horz 2 = -118(LC 9) Max Uplift 2 = -281(LC 8) 14 = -704(LC 5) 9 = -293(LC 28) Max Grav 2 = 774(LC 19) 14 = 2405(LC 1) 9 = 889(LC 1) FORCES. (to) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1921/665, 3-23=-221/923, 23-24=-221/922, 24-25=-221/922, 4-25=-221/921, 4-5=277/1072, 56=-487/411, 6-7=941/395, 7-8=-1107/413,8-9=1386/490 BOTCHORD 2-16=537/1711, 16-26=-512/1645, 26-27=512/1645, 27-28=512/1645, 15-28=512/1645, 14-15=2390/709, BOTCHORD 2-16=537/1711,16-26=-512/1645, 26-27=512/1645, 27-28=512/1645, 15-28=51211645, 14-15=-2390/709, 4-15=622/416,12-13=-340/816, 11 -1 2=-340/816, 9-11=-354/1212 WEBS 3-15=2608/810,13-15=-293/660, 5-15=1498/465, 5-13=-90/414, 6-13�669/224, 6-11=9/260, 7-11=64/323,8-11=-323/224, 3-16=-94/963 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.0psf; h=13111; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) . This truss has been designed for a live load of 20:Opsf on the bottom chord in all areas where a rectangle 35-0 tall by 2-M wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSUTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 281 to uplift at joint 2, 704 lb uplift at joint 14 and 2931b uplift at joint 9. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 252 lb down and 251 lb up at 7-1-8, 114 lb down and 127 to up at 9-0-12, and 114 to down and 127 to up at 11-0-12, and 114 lb down and 127 lb up at 13-0-12 on top chord, and 349 lb down and 79 lb up at 7-1-8, 87 lb down at 9-0-12, and 87 lb down at 11-0-12, and 87 lb down at 13-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (pit) Vert: 1-3=-54, 3-7=54, 7-10=-54, 16-17=-20, 15-16=20114-20=-20 Concentrated Loads (lb) Vert: 3=-200(B) 16=349(B) 23=-114(B) 24=114(B) 25=-114(B)26=-68(B)27=-68(B)28=-68(B) /r at aewe ,pqm m uix;nma>•®s'}cmurtwsammimrmsiauRaa:uuc5,uaarem`mhm�w=+ms�vomne:,an4.c aiAAidm�rTu:tknmvmrumx.m+ e�mtes.mmd a rea..ry �\\ wr<lamarzs!mzamF.uammmoptrdil LmMgehr!eW 9mnathmx;.Y.utl mmwmwumpw+xmvd+vbdR'�nv"v�ogmmanpxm�vy tnstyW crmmo+tlr ansttYcsumx,srmedwad'mvtme9p aa,newmnaeazean / \ d9d5q$mlacl v3h6¢gmMR+tlb➢m46x+arsr�LtlS%ikmMka3anPv b,W¢dm PCmffio!&Ydktlgdxs+Vn -wob dW�dbla9sbufktl netmrmsh9rgtrd�3 'N,9rGAofmtlYi5a55dkmkRv+rs1A vm eoxouseenemren.e Gs,stS �/ •■ A� m.�Y�'im marmem mw„riendatm�aq�araavx�rta7aan�P�m,ucwd64FomsnenarmSy+ew.arumnQgmrom�.w,las`axxnm+n,�l�,mnau7?meu]mfvcrtma� n•utg�.ara emmu(�d&eM1mnrp,waa:,vrh6pvms,a.:t,lnfxivrlmarepm,t/rba�ahxsw im Sro®Newsmmlmy mw�aem exanmi: n.ays.e � one: oansane [nplrigtr@PhdAllodTmsses Amdav/LTvmEnN,PE Eeprn'vdiwAld'u{vroipjC,one%1em�lsp�oht'SeQiYhemMevmnetF,upupnM1vm/lAwtL rlit AMun(i.RmluN;PE Job Truss Truss Type DtY PlY WRMSBMB3 BO1G ROOF SPECIAL GIRDER 1 1 �RENARMORNINGSIDE AO133445 Jab Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, deslgn(rDaltruss.com ymy1 8' Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Mon Sep 1711:33:42 2018 Page 1 Dead Load Dell. = 3/16 in 3x6 = 1.5x4 11 5.6 = 5x10 = 4.611 7-0-0 12-11-1 18-8-8 24-7-10 7-0-0 5-11-1 I 5-9-6 I 5-11-2 Plate Offsets (X Y)— I3:0-5-0 0-2-01 I5:0-3-0 0-3-01 I7:Edge 0-3-81 (9:0-3-0 0-3-01 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) 1/deti L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.91 Vert(LL) 0.17 9 >999 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.96 Vert(CT) -0.32 9-10 >923 240 BCLL 0.0 Rep Stress Incr ' NO WB 0.90 Horz(CT) 0.09 7 n/a n/a BCDL 10.0 Code FBC2017/rP12014 Matrix -MS Weight: 125 lb FT = 10% LUMBER - TOP CHORD 2x4 SP M 30 -Except' T3: 2x4 SP No.2 BOTCHORD 2x4 SP M 30'Except• Bt: 2x4 SP No.2 WEBS 2x4 SP No.3 *Except* W2: 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 1-7-8 no pudins, except end verticals. BOTCHORD Rigid ceiling directly applied or 5-8-10 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 7 = 197410-3-0 (min. 0-2-5) 2 = 183910-8-0 (min. 0-2-3) Max Horz 2 = 166(LC 27) Max Uplift 7 = -658(LC 5) 2 = 585(LC 8) Max Grav 7 = 1974(LC 1) 2 = 1839(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=-3450/1117, 3-14=-3626/1226, 14-15=-3626/1226, 4-15=3626/1226, 4-16=-2645/884, 16-17=-2645/884, 5-17=-2645/884, 5-18=-2645/884, 18-19=2645/884, 19-20=2645/884, 6-20=-2645/884, 6-7=-1848/702 BOTCHORD 2-10=-1036/3016,10-21=-1037/3042, 21-22=1037/3042, 9-22=1037/3042, 9-23=-1236/3628, 23-24=-1236/3628, 8-24=-1236/3628 WEBS 3-10=-51/705, 3-9=274R71, 4-9=-92/264, WEBS 3-10=51/705, 3-9=274/771, 4-9=-92/264, 4-8=-1154/413, 5-8=-666/461, 6-8=-1015/3041 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf, h=13ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 658 lb uplift at joint 7 and 585 lb uplift at joint 2. 7) Hanger(s) or other connection devices) shall be provided sufficient to support concentrated load(s) 158 lb down and 187 lb up at 7-0-0, 110 Ile down and 122 Ib up at 9-0-12, 110 Ib down and 122 Ib up at 11-0-12 , 110 lb down and 122 lb up at 13-0-12, 110 lb down and 122 lb up at 15-0-12, 110 lb down and 122 It, up at 17-0-12, 110 lb down and 122 lb up at 19-0-12, and 110 lb down and 122 lb up at 21-0-12, and 110 lb down and 122 lb up at 23-0-12 on top chord, and 414 lb down and 144 lb up at 7-0-0, 86 lb down at 9-0-12, 86 lb down at 11-0-12, 86 lb down at 13-0-12, 86 lb down at 15-0-12, 86 lb down at 17-0-12, 86 lb down at 19-0-12, and 86 Ito down at 21-0-12, and 86 lb down at 23-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead +Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-6=54, 7-11=-20 Concentrated Loads (Ib) Vert: 3=111(F) 9=65(F) 10=414(F) 4=-110(F) 14=-110(F) 15=110(F) 16=-110(F)17=-110(F) 18=-110(F) 19=110(F) 20=-110(F)21=-65(F) 22=-65(F)23=-65(F)24=65(F)25=-65(F)26=-65(F) 27=-65(F) Nlxi1181J(RIIfP)6nillltlVirN1WIICRf61W6(61�'71mCn®:9fW�d¢IaSl4Yi Pltli^1drcJ6n¢h11mf1¢4lmvq(RL'Icih4As111aYh'rt4lvarRMlM1rtu MulCa.mL'�oMln a} Old. 1WS Wl6 1UW1.6PMY(EiilJ1iLYLMbriWKr Clft Jnro�BOunm PE6t009 ,ftq,eyiwpl.lptl9.6sas)kui¢NNEnPl+mtu6mp1WbkAW.1f1W X9 11tr ftWiRsa{,imst'!aM¢11 dMt'ak gNWeiMbRBsipnliA hR50,Idlli:hB IbRNlilerYle@�IXL iL9TNid®4tlN6etl W6L, InMv4lblailM9 Cs90brIM311�AL•L-nq'�md" Pi54tQkn rRl4rtlrybell 11;: Wk g"ho,'i'Wft'r BnnGW91615 Afrm!lWiE+ry1lMtlEx bMlry WgndReY.a NuhsYMr6NUd6ptli¢imlpdASAO'LYgly;.eeY4CxvmlppldN4l6rgml WJm�M®Ihpm'pinz.➢H 65it4mpadixn=Id4i®¢L 1pnp l,ntGcyh¢+aelPauGo[�v.es[ 1�5161moa Bd. p.Pi,q �yyy 6fetllmlbdN lctelgetlyvbxNglimpmul,irt avlml0ugtgantllgOlaWqk;.a lmntrneae{amLglNIq WW»adc'tl, reul3xibRF1. ene: ¢LIYN18 [eppnphO101611fvdfmms-Amdahl.lomdv POPE Iepndedmvvhditivmvev4maophm,rspivllaednWvoWevmWvpgmiimvhvaAl Havliniu;•AeRm/r.lvmldN,lE Job Truss Truss Type Cry Ply RENARMORNINGSIDE A0133446 WRMSBM83 B02 HALF HIP 1 1 Job Reference (optional) A-1 Roof Trusses, Fort Plerce, FL 34946, design@altruss.com 46 6.00 12 Run: 8.210 s May 182018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Man Sep 17 11:33:43 2018 ID:tW YXbtUG W VXBg9MPyEYwl7zgtLu-O78WG2_QBvUyYB9U(@LF ViTnFW OSzFdTn 3x4 = DeaQpad Dell. =1141n 3x4 = 3x4 = 3x4 = 3z4 = 3x6 11 9-0-0 1G9-13 24-7-10 9-0-U I 7-9-13 7-9-13 Plate Offsets (X YI— I2:0-0-8 Edgel LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well L/d PLATES GRIP TCLL 20.0 Plate Gdp DOL 1.25 TC 0.68 Vert(L-) 0.26 9-12 >999 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.82 Vert(CT) -0.40 9-12 >736 240 BCLL 0.0 Rep Stress Incr YES WB 0.49 Hom(CT) 0.03 6 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 1221b FT = 10% LUMBER - TOP CHORD 2x4 SP M 30 'Except' T2: 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-1-5 oc puriins, except end verticals. BOTCHORD Rigid calling directly applied or 5-5-10 oc bracing. WEBS 1 Row at midpt 4-9, 5-7 MTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (Ib/size) 6 = 904/0-3-0 (min. 0-1-8) 2 = 98410-8-0 (min. 0-1-8) Max Horz 2 = 207(LC 12) Max Uplift 6 = -267(LC 9) 2 = -218(LC 12) Max Grav 6 = 904(LC 1) 2 = 984(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1447/761, 3-4=-1211f797, 4-5=-11321692, 5-6=-831/569 BOT CHORD 2-9=-800/1206, 8-9=69211132, 7-8=-692/1132 WEBS 3-9=0/313, 4-7=-512/503, 5-7=-784/1280 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exteror(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to beadng.plate capable of withstanding 2671b uplift at joint 6 and 218 lb uplift at joint 2. - LOAD CASE(S) Standard pry kummpsmam Nice;nmaPsnury¢rsu�stmamossmnprl!�m7umcoatirmnnrrm,�T,®x„m,dwr mmum,gm:m[�mm�mriw.asin.m�sMxd..m. mw,.m+meadamlW.� I Wlet�mmxrhmffikvlmmnrrEknFd hrimsrwpipevpyympyfixseymvi glnrtpr95mvrtpmxpmplMprdrprmq A e�urmmsmp,4msrf,ms LyMmmIDOCr matnt lb4Npwgm6WLgm9emL9tm19l. JamrBPmW PE6m09 mwpLlmvhmlgYvihmmM M.'fm0a4i0mf1rSiM HJIm4Yr3Ee4x. hw^Ytlmp[.mC.mp[6JfdYSo4 PdI1N.N4RnLdm141dahnNCm1wt69-itm'i1mR.tl0e0vmYn3d�bh¢�LLfin[ rxob Max 9MMe�✓q G91p19 mmmiwaaa[mar>o.x�ramvmmmvmmlomvp•o`nmrw.mr�mssapx�•^wkW°tihummre�®ss pmapmo.mia�sanvm+aaasmeaieaua pup.lmsoxo?asemrw+eevvcm rtv'w��.nv�'9 raeduMvJ{nfm+orri,psriRghmrvmewid.lbtmsttupfgmenrntileY,nhrgm elm,l�m6imvemm9pa Uamm(mmnmiinsbml. oms oenvmse • (rppiB31®7plldl Wdinssm-Adiagl.Iepir N,Pi lepmip0'iosdd'npmpFegr mrvptem,nyiohbile(s�rNlEevMeppeim svahoml lAwlinsus AelEevr7.TemEom,Pi Jab Truss Truss Type Ory Ply=RENARINGSIDE WRMSBMB3 CO1G GABLE 1 AO133447 onal A-T Root Trusses, ton vierce, FL Sri b,oeSlgn(rDal Wss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Mon Sep 17 11:33:44 2018 44 = 10 3x4.= 4x4 = 4.4 = 5.6 = 44 = 44 = 3x4 = LOADING(psf) SPACING- 2-0-0 CST. DEFL. in (loc) I/deft L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.14 Vert(LL) 0.05 24 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.37 Veit(CT) -0.08 24 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.34 HOrz(CT) 0.02 19 n/a n/a BCDL 10.0 Code FBC2017/rP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 5-1-2 oc pudins. BOTCHORD Rigid ceiling directly applied or 9-7-6 oc bracing. JOINTS 1 Brace at Jt(s): 9, 13, 7,15 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (Ib/size) 19 = 78310-8-0 (min. 0-1-8) 2 = 78310-8-0 (min. 0-1-8) Max Horz 2 = 90(LC 33) Max Uplift 19 = -162(LC 9) 2 = -203(LC 8) Max Grav 19 = 783(LC 1) 2 = 783(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 23=-1341/299, 3-4=-965/164, 4-6=-945/182, 6-8=966/218, 8-10=940/248,10-12=-940/258, 12-14=9661237, 14-16=-945/202, 16-18=965/183, 18-19=-13711217, 3-5=-411/194, 5-7=411/194, 7-9=-445/241, 9-11=445/241, 11-13=-414/242,13-15=-414/242, 15-17=-463/139,17-18=-463/139 BOTCHORD 2-25=-303/1241, 25-32=376/1228, 24-32=376/1226, 24-33=15/320, 23-33=15/320, 23-34=-15/320, BOTCHORD 2-25=-303/1241, 25-32=-376/1228, 24-32=-376/1228, 24-33=-15/320, 23-33=151320, 23-34=-151320, 22-34=-15/320, 22-35=-274/1202, 21-35=-274/1202, 19-21=-148/1213 WEBS 10-11=-1501665, 11-24=-347/909, 15-21=-10 11271, 11-22=-286/911 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vas.=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as perANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Gable studs spaced at 2-M oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 8) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 162 Ito uplift at joint 19 and 203 lb uplift at joint 2. 10) Graphical pudin representation does not depict the size or the orientation of the pudin along the top and/or bottom chord. PLATES GRIP MT20 2441190 Weight:1351b FT=10% 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 57 lb down and 35 lb up at 2-0-7, and 160 lb down and 73 lb up at 17-3-9 on top chord, and 76 Ito down and 35 lb up at 2-0-0, 16 lb down and 1 lb up at 4-0-12, 16 lb down and 1 to up at 6-0-12, 16 lb down and 1 lb up at 8-0-12, 16 lb down and 1 lb up at 9-8-0, 16 lb down and 1 lb up at 1.1-3-4, 16 lb down and 1 Ito up at 13-3-4, and 16 lb down and 1 Ito up at 15-3-4, and 76 lb down and 35 lb up at 17-3-4 on bottom chord. The designlselection of such connection device(s) is the responsibility of others. 12) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (pig Vert: 1-3=54, 3-1 O=54, 10-18=54, 18-20=54, 26-29=20 Concentrated Loads (Ib) Vert: 24=1 (B) 22=1 (B) 23=1 (B) 21 =3(B) 25=3(B) 32=1 (B) 33=1 (B) 34=1 (B) 35=1 (B) rwW r¢mavrhms n uisrnsv3(mmy¢e�ntlsinrwim2etml,>m(rnn ULr%evlal'mnicPrkvplvmAsd i.+n rssr�a:roh�vall�daaevvriu�tiir�xa�v=. �n .e.+wamtoaloo m� wr,.wo.lm:maeamemone,ant Nssrmp0panp W.Irnuvsmwil a,moromm�mnnAaa,,atrvuz:migv,m:�asrtsmRuyvAau7 urntlsm�+»alroy muu mrspw>rmse:twv�nueaxt aa".leo��wvrsxam d'wtlPRfdvacftv�OfRmvgmbAtlmOm4YeMs'ssffi9tlR3 btnllripmym,R4fmvdmfdmt e1m69Y.-0(9Med1r.3NgprAdaMdmbn vdmlrink!&h"9tl„ia'446tE�vthlvld9mhv9"!r3'y1Y wob xoux EigreennAG3fsf5 mm' RAmi MrmEC NvfsWWwalr0dalMvdalPtl'➢sdY ke%fvµreYtllKmmv:Oa,f�+Nl(]nldSPlrtflxmdf9�4Lv➢d Mmm 5lnsmb6MlSA>ti4f y'n�w,ollauMry'Wvv:� nV6 ._ OeCpw,l,m4n _ us Sua vh+L RP'u¢e Fi 3,918 I�IY�dM0I1d91 9wdSvEgC61h A1caf �reY$!n Wyfilen,hlDT4rAnryhzgm lmslpia[g3elLvrWkp aoprJnAhwmm2Wvnrl. oge Oyl5rzof9 • (vpyri9�mi01AA 1lvelTmfrrs-imdavyL7vmhelltl.E Ivplodu�ios Allbdaxmev5ivnvyfvro4isyioG3AeLvAmNkewmRepeiviisnvehv®A IBmlimsks, AelAvvy! iv®ldOt,LE Job Truss Truss Type Ply RENAR MORNINGSIDE A0133448 WRMSBMB3 CO2 Common rty Job Reference (optional) n i rewi uue5e5, run r,erce, ru .1r�vv, uesgnLa nruss.com 6.00 Ff2 2 �1 Ora = 1.5x4 3 i KUn:0.Z1U5 May-@N10rrmcU.Z1U5May1UZU16MIIeK 4x4 = 0 1.5x4 i 5 IOC. Man Jep 1 / 11:3J:9 zu10 Dead Load Deft. =1/6 in 6 �7 4x4 = LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deb Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.44 Vert(LL) -0.14 8-14 >999 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.85 Vert(CT) -0.30 8-14 >782� 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.21 Hou(CT) 0.03 6 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 87 lb FT=10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-0-8 oc purins. BOTCHORD Rigid ceiling directly applied or 7-9-1 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation uide. REACTIONS.. (lb/size) 2 = 791/0-M (min. 0-1-8) 6 = 791/0-8-0 (min. 0-1-8) Max Ho¢ 2 = -90(LC 10) Max Uplift 2 = -205(LC 12) 6 = -205(LC 13) Max Grav 2 = 791(LC 1) 6 = 791(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-1182/782, 3-4=-897/583, 4-5=-897/583, 5-6=-1182(782 BOTCHORD 2-8=-555/1035, 6-8=566/1035 WEBS 4-8=-275/557, 5-8=342/383, 3-8=-342/383 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult-160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsh h=13ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 4)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by .others) ,of truss to bearing plate capable of withstanding 205lb uplift at joint 2 and 205 Ib uplift at joint 6. LOAD CASE(S) Standard dwq.hmem$irmesp'11 Cwri�+r,rl'ml4lmaSt®aeaffimvssmn;s(mi0lrmosivaarac rnermapr�^d,dstiaaa,Anta�Qmartini�imL�r.t�e4a1dem4aly ean.ma.mwdue`vmomry ' 4Rf;nmOn{Milflh WNpMIM1kNkbeLm@s�rN?M1(U.§e'N%rkeZt4alMWIGQi4m�wmgtma3tl YdsPd 3Q?ImRbBR�&er,�Av[uy?i+sHgdnMlWe§ml lfl{ihi zpnnupNm,Y£9m9ovf.aM9P.. .Im,mernmlm5a¢xem diadSZFmvbWlWagrz&mtaAMa9eomchQ'mitrdktrdeT4tlQ,MIf+IQ�.M4�v.1^niNOLNCeilPoMhb3ru4eiBl h@Pmildi46etlm➢etllsedkrmsevltr{L-BAmB'dtlA�id,�>01QhR^Paairld' vmo¢xaum [�eu,ea.e Cns,sis muq'}uquaerm.ar un+s3�mxea�adtic+emetno-luvgoaeRF'n�"l�R�6dwutimme�dle.iroM1e�m1M.¢saz+w=dsadareee.M1 aw<1,uM1ml.OT gS�r�vmmmm - n.w�`"i�°xm"°su tSv16eM+dhrtutmeYeUTeYgmgtrellAwfrdrW-ieelouGpPkl6iexsnp6+kp fattSY4rt8ba[mtWkµ W4�a�emmmtAWCRFT one: aens¢me (v O QldA llvdT pyig§I 1 tivvn�MbanpP.lam6CN,PP¢eprodo�avdtbutomoevl�ievgh�aptvbt5ifepxtlhvm@avtitltvp;mtissivvhvmkDvatlretu!-bftvlp'i-iA6lo10,4E Job Truss Truss Type Oty PIY RENARMCIRNINGSIDE WRMSBMB3 CO3 Common 1 1 A0133449 Job Reference (013tionall r•-, ,.w, ,,,.,,00, .,,. , ....00.w,,, rtun: o.e w s may io m is rnnr. o.z m s may ac zu is ini i ex mcusmes, inc. mon oep i r I VJJ:40 to 10 t ID:tWYXbtUGWVXBg9MPyEYwl7zgtLu-KWGGhkOgiWkgnVJFel4pKwosm2ZtsPxYSnKp 414 = Dead Load Defl. = 3116 in 4 6A 414 = Sx8 = 4x4 = LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.45 Ven(LL) -0.14 7-13 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.82 Vert(CT) -0.31 7-13 >745 240 BCLL 0.0 ' Rep Stress Incr YES WS 0.20 Horz(CT) 0.03 6 n/a n/a BCDL 10.0 Code FBC2017/iP12014 Matrix -MS Weight: 84 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-0-14 oc purlins. BOT CHORD Rigid ceiling directly applied or 7-5-9 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 6 = 69910-3-8 (min. 0-1-8) 2 = 78010-8-0 (min. 0-1-8) Max Horz 2 = 100(1-C 12) Max Uplift 6 = -165(LC 13) 2 = -203(LC 12) Max Grav 6 = 699(LC 1) 2 = 780(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=-11551775, 34=869/576, 4-5=-865/574, 5-6=-11341759 BOTCHORD 2-7=-611/1011, 6-7=589/968 WEBS 4-7=-266/528, 5-7=303/359, 3-7=-343/383 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capableof withstanding 165 lb uplift at joint 6 and 203 lb uplift at joint 2. LOAD CASE(S) Standard n9 llm�0mm'WrWLiman roAImMr11m fcA@'g 'm iouaarul,rnrs' Mbuw ft4rtddd &TA'anYW BPE. tla�E06t tralWYmiebrt,rm-LR drv0vm4ti0mrb dWabrwYa3rnCndPa`mndbrLbB etlMfidhtlyolSaf bFL ik4iaddhiCrado,br ertbimtME.7m'Y�,,kYriatalYnfG9Yhrtgasbl'-0d comb Ewu rMseenNen9in5 ust 9 Wie eM, tYssptr4e,d MnbsuinlbbidrtlbFdls{OfPd'y-M1IY4AlgrW1'ar�t6vefu'ttff11dYWNlXtllilnMyWrtrimRdP�1M1ihA35b!R4%dS¢mlphl�N'Im Md0E 1rm5rPGD'+amlmttlENOin,aS3 d} gMryubmm�„tlhmEw YdµlYln kuplgsn,Glrl6rYlTrhij'p tin¢Sp!eiga Eml1°ai aN>dlk nmltxdbRn D.: WeVne ba,e: OEnimM9 Gprr8bb 10dbAlfvdinsses-dmd Jii mobm,/.E Repmdvatve ofldiskmvevFuvvylva4isptod3AeLvddvdlae vnbeepeimiisivvhvmAlHdtlimsu[ AVPovvri.lvvd6m,PF Job Truss Truss Type Oty PN RENAR MORNINGSIDE A0133460 WRMSBMB3 C04G Hip Girder 1 1 .lob Reference (optionall A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com 6.00 F,2 314 = 4x4 12 1.5x4 II 4.24 FIT Run:8.210s May 182018 Print: 8.210 s May 182018 MiTek Indus ID:tWYXbtUGW VXBg9MPyEYwl7zgtLu-pigev4l 44 = 1 414 = 22 11 23 70 24 1.5x4 11 1.5x4 11 LOADING (pat) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.21 Vert(L-) -0.0311-12 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.29 Vert(CT) -0.05 9-10 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.05 Horz(CT) 0.01 7 We n1a BCDL 10.0 Code FBC2017frP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 515/0-M (min. 0-1-8) 7 = 515/043-0 (min. 0-1-8) Max Horz 2 = 41(LC 34) Max Uplift 2 = -182(LC 8) 7 = -199(LC 9) Max Grav 2 = 515(LC 1) 7 = 515(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-784/217, 3-19=763/231, 4-19=-716/231, 4-20=6941236, 5-20=-694Y236, 5-21=716/230, 6-21=764/230, 6-7=-784/221 BOT CHORD 2-12=179/693, 12-22=-1661688, 11 -22=-1 66/688,11-23=-164/694, 10-23=-164/694, 10-24=-1641688, 9-24=164/688, 7-9=-1751693 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. S) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 182 lb uplift at joint 2 and 199 lb uplift at joint 7. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 40 lb down and 48 lb up at 4-0-1, 44 lb down and 65 lb up at 5-10-0, and 40 It, down and 48 lb up at 7-7-13, and 127 lb down and 133 lb up at 10-3-5 on top chord , and 19 lb down and 72 lb up at 14-11, 22 It, down at 4-0-1, 34 Ito dawn at 5-0-14, 33 lb down at 5-10-0, 34 lb down at 6-7-1, and 22 lb down at 7-7-13, and 19 lb down and 72 lb up at 10-3-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-4=-54, 4-5=54, 5-6=54, 6-8=54, 13-16=-20 Concentrated Loads (lb) Vert: 12=45(F) 9=45(F) 10=16(17) 11=16(F) 19=-2(F) 20=-33(F) 21=-2(F) 22=-6(F) 23=25(F) 24=6(F) Mon Sep 17 11:33:46 6 4x4 -- 7 k d s a o- 1.5x4 II 3x4 = 1-& 1-4-12 PLATES GRIP MT20 244/190 Weight: 48 lb FT=10% @°NI@m@ke'MlmYrh'31�F115Wf1amlYCi3[RnftrRillCHfffiIOtl(LLRa'ila!2G�a5Hl`EmY¢tl1�21�e�ed�eleirsnYtwvAnP�'e°9(�itlfiL9a91./e�R1FWe®4rEfL� EM1e QslrtffiN Y`1W.d/ WtnlnV2litY@@3em1YY1C1.trkN@LelmsBwPtiranN lR�leovsibeftl e51BBW+ne6n®elEaa@@PAnfbde�'+rea9 i'^kY1bY44pASt+%�e1mLTbelu4lRefV WaR}Lldls9enusn'nb�vtluryse9l4 Yerte OumevESzms tlne@kttauYixhHktkYln(uLCQ(YMw.YeOrn'{(GLEtlW4hhMry@eWrt 6mGR@Y6r.YCN'44r11+iWxdeedSfl.lb@i1ASb14401 WSJl rtdpilWtv2S1F�,.qi¢nRSh�Lftl_6trte510ilkL^�egy33l1f. WMh Mnuv EMneai„O G91a15 ' YbTg4;¢yntltmY AdtrhMWtrhte4MYNW�o1PCYn@l Wipl<h'rys5Le4Pk��.M>l�klXelLp¢n0�llet�4'kR 1M1QAfiv_sR rzq�5lmetd�bb@Ff mbLAE.Y�a.S,.��p 1avYl�LmdaN� ust suuw ahe vRevYiGNlryuadmtl5n4yGwkm/rtsM3ieLtkinureu;Faam'6ANY93NvrY� lvnit>feigYvrtm�ltCopxYiv�nnmeamdvtM1t. om: mnvmee � (v t1@ 1 Adrvuimsses- Ivv 1. tEcECIN,V.L Be mdvd'nAnnbvmmpm,mv tvrgn �vhi6@edtr@dvvlMer'N2v 5itiv hamAlAvdLvsiiL Avftv 7;IDvAo01,YF Job Truss Truss Type Qty PIY RENARMORNINGSIDE WRMSBMB3 C05 Common 1 1 A01334511 J b Refe ence (ooti na0 n .. uuexa, en P;. w, FL 34946, csiynl,e,nuss.rrom nun: 8.21u 5 May Id ZU18 Ynm: 8.21U s May 18 2018 MITek Industries, Inc- Mon Sep 1711:33:46 2018 ID:tWYXbtUGW VXBggMPyEYwl 7zgtLu-pigev4l lUgsXPfuSC7b2t8K3nSOsbughKQ3G -1A-0 5-10-0 _ 1 11-3-8 4z4 = 4 Ig 1.5x4 11 3x4 = 314 = LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.37 Vert(CL) -0.04 5-11 >999 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.32 Vert(CT) -0.07 5-11 >999 240 BCLL 0.0 ' Rep Stress Incr YES WS 0.10 Horz(CT) 0.01 4 n/a nla BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 42 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOTCHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MITek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. (lb/size) 4 = 413/0-3-8 (min. 0-1-8) 2 = 49810-8-0 (min. 0-1-8) Max Horz 2 = 71(LC 12) Max Uplift 4 = -97(LC 13) 2 = -137(LC 12) Max Grav 4 = 413(LC 1) 2 = 498(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-567/404, 34=-570/406 BOTCHORD 2-5=-249/452, 4-5=249/452 WEBS 3-5=-14/251 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult--160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat. II; ExpB; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) `This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 971b uplift at joint 4 and 137 lb uplift at joint 2. LOAD CASE(S) Standard %'a9 r:av�mu:m•urmrne¢(Sm�ye,xu[omsauvmoramt;ft�:9aiwcrasuerra�rravpmaav+d,d.i rum t Hs�Akidmees,lc�,Kithm�axtLhe and:�.n,daanaiW..ry vrtaaRarka0mu wmmnvotrK4q uuo5ntrf%el� yan'ryamY,A,u� mnamx�smamvd+a�w+'�x�mwnanrtrmwnavew+,mehdd,.nmoq, emma rn„q+v,nvPmaev�msw4Aeest.. v.re�ew.��ae sseos dmd4aiwE,ellvb'Wk6vtr kin d@Om4Y40 srfi3¢dryiemMWAnC•rt.\mnmitdh OC9sXtlt iolMY%io4vllVn NPP„CamlAlcfmkl 6&tmcFJ!=1tm4; 5'sP tt02satlYeriyilmmm^WuS,IAd. wnox xeux EnWreanMG9,5,5 '.. marncuvma.<es,mw.nroaav�,mwwa nma�unmm9�mxvm.:mnKmaHmernu xnw4At`1�a{+4m. mrnvgitirrym3laev Ymmapua mapa rs?evW^vrTm.emre6x.ra a��'rlsawv re.�si�igvuxmrs�N.ovKggmtemvme�.Likln�War�srJ[mtalnMm 1x slM1avfewAaotxanx wwvavam.smvWaaAmt orz venvzo,s tiPYn9ti ®.PdIAA i AvvtTnsses-iveav)i. iv¢hv(I6 i.E tepmEv7lavv(Iiudvmmevl,iv®ykrvyn�roGldepenhvmihSvribtvymmiisivvdvmA-I flvviinsiei�AviSvvrl,Temco Ol,Pi Job Truss Truss Type my Plv RENAR MORN INGSIDE A01334$2 WRMSBMB3 CA Comer Jack 10 Job Reference (optional) A-i Kooi I nlsses, Yon meroe, rL 34 b, oesignLgaiimss.com Kun: u.4lu s may is au ra rnno o.z m s may io zu i o mu 3 6.00 12 MAI y �i 2 TI B7 c �• 4 1 p° 214 = LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (too) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) 0.00 7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL . 1.25 BC 0.03 Vert(CT) .0.00 7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 4 We n/a BCDL 10.0 Code FBC2017frP12014 Matdx-MP Weight: 61b FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 0-11-11 oc puriins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. (lb/size) 3 =-3/Mechanical 2 = 166/0-8-0 (min. 0-1-8) 4 = -16/Mechanical Max Horz 2 = 42(LC 12) Max Uplift 3 = -3(LC 1) 2 = -70(LC 12) 4 = -16(LC 1) Max Grav 3 = 12(LC 8) 2 = 166(LC 1) 4 = 20(LC 8) FORCES. (lb) Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult--160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDLm5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-" wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 3 lb uplift at joint 3, 70 Ib uplift at joint 2 and 16 lb uplift at joint 4. LOAD CASE(S) Standard 0 cap.rm a�.yvrma ix'urret�ssfcwaluwtrtmamamasonmi^cvalunnct®ruerr�5a¢re�g,w®+„mrts.azae�i�m�®.aymq¢a4r,esri.u�Riiusms>�n�. m��m. ma s•mam!r wram o¢rmnsss,.mmanomnmxm.um Pagragv N fyvMwx4�rv�nmrma�smeercn ec.rammdgwMa waanrtrmawdaw muq�matca,�aw_mt>ma pww+u�ocw,,nmeq. aa,ne w,ue aeezeos faas<tSntm�a,�wauhasry�&pana.¢+®s.¢ose�a!�er�dryEaw- e.,maese[ea musaau�,m-�et�trvmmdmrmWr uv amr�,croslr +ra+vmmmmtaubu,°�ana; w,a, Hwwe�em�.�ae•sre�s �/� \i rsAa wfmw Naarwxar.memrerausbf an. ..n�(�. wmtmveMAamar�mPtae.lrue•orim assa:amaentrei i�mon mAtmsrmuv.,ibs .as swa. a�w. .x,maar JH+�dam+9mti+wyhw��rt.7tii [eiara�¢kAoraHvalMpa toas�sanao�am[�tiarok»�aa�.muwnmt" o�: oa¢vema � CapygDl Q2!'IdAl Walihssa-A¢16nvyi.iomhvJl4PL' leprvdoDtmdt4uivmoeM,umyfvrm.isP�a316jlepeAhemffi¢rd11p¢y¢imsuvr5¢mAlpaallnysLAvlAv¢yi.r¢mldIll;Pi. Job Truss Truss Type Ply=RENARINGSIDE WRMSEIM133 CJ1A Comer Jack r A0133453 nal u—.' ari=, , L.r,wu, u=aiyuL,=mueswm rom:5.ZIU5 Mavto ZU1dPnm:e.z1us Mavlazetamilex mousmes. Inc. MonseDlill a LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (too) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) 0.00 7 >999 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.03 Vert(CT) 0.00 7 >999 240 SCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 2 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MP Weight: 61b FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 0-11-11 oc puriins. BOTCHORD Rigid ceiling direcUy applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = A/Mechanical 2 = 16610-M (min. 0-1-8) 4 = -15/Mechanical Max Hom 2 = 42(LC 12) Max Uplift 3 = 4(LC 1) 2 = -63(LC 12) 4 = -15(LC 1) Max Grav 3 = 11(LC 8) 2 = 166(LC 1) 4 = 17(LC 8) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.0psf, h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 2 considers parallel to grain value using ANS1rrPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 Ito uplift at joint 3, 63 Ito uplift at joint 2 and 15 Ito uplift at joint 4. LOAD CASE(S) Standard Eauy'NRelrun{IrnMmYllIDfDdIIi((QBfPy6Di1lIN8f f0it111Ln0B0Y(hla'I 'WTJKWI`bc WM1jh TI+1v�drtilelaYm[Mv9¢pknml�°jdm4Lli ie34lFldma4,IkMu mnlCsbSTlemID1 m} Wl Ylmmn%m Aflb,ulhblYu9M,lttb Unllnq[f�pn (I Spro'rybhs}WW v1140ryrt¢Yvv¢'IVRAm#E umdymmrynAmm�RhmWgni4uj AsllvAamlC9ab R1v11H ia1wpmnmaary45yatles4RfiAEry JeretBdalep PE uatB d ,i4Gussh: m�6ghmrtlpmallhtlbgvutbmvm'1F6eCtiv:9mmlvW.Pmlgm.YtrmsAAb BGmLdmgdlwllgnh MlBi Mgpne'iblPBdaetl tlmthrtiLm�trrLZStiB.hmgAmefhtmrilabmhga,3lnd. I V,TaeNvv HgWenry Cn9tfi15 Cbkrypsy�edGvi0¢AAmmYNYmiC4dmpmatml#JtlwtlmekJlgheam YegKssmvpoplkNtl%IgtlLfluMumEtiimm'ptl7:1M11@frs[4a1rym8raa HbEtiAMlatbLpa lmsOnpLyevrdFm[eGuun,slo] �1m��. RP'nu,RN9Yfi 1Mrmldldir LagryHyvl�9'gMdpwL_j,rl•Nlmfla[y FamrhlCltrlfJphgrY fR �trmm q Y a 21m1tvn Ih4Y1lPl. U(av col a4 mf One: OYISR018 . Gppigii0l➢IAAlbdinsses�,l¢IAAi1l.leviAllAPi Dp�ogvAiAAdtP6domvem,mvJfwynjiiEihkPmohcmlAe vfihA pelmiiwo5AmAl Havlirisies AIAAvrLibmkolll,PE Job Truss Truss Type aty Ply A0133454 WRMSBMB3 CAB Comer Jack 1 1 �RENARMORNINGSIDE Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@aluuss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MTek Industries, Inc. Mon Sep 1711:33:48 2018 6.00 12 T7 d t Ib l 3 vn d d 4° Q° 3.00 12 3x4 I LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.01 Vart(LL) -0.00 6 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.01 Vert(CT) -0.00 6 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 2 n/a We BCDL 10.0 Code FBC2017/rP12014 Matrix -MP Weight: alb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 0-11-11 oc pudins. BOTCHORD Rigid ceiling directly applied or 10-M oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 36/0-8-0 (min. 0-1-8) 2 = 21/Mechanical 3 = IS/Mechanical Max Horz 1 = 20(LC 12) Max Uplift 1 = -2(LC 12) 2 = -15(LC 12) 3 = -5(LC 12) Max Grav 1 = 36(LC 1) 2 = 21(LC 1) 3 = 16(LC 3) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpl=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) n This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 1 considers parallel to grain value using ANSVTPI I angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 2 Ib uplift at joint 1, 15 lb uplift at joint 2 and 5 Ib uplift at joint 3. LOAD CASE(S) Standard rdy.rnnrmryymu.m'eauvirussrs(m�trymiztmaerumm�msmnryualm,nrosvarnn reerahr,mm„d,d.enmmumoegp,r�IrtgdmAwrtt.3,4ittdnrnn,ert r°,. mn,ree e,aednalm.Pry I Wrmnvmlmd91mm1mminpM1mil vu ,vm¢fmm?M.Lvmhbpxtmml gmnpmmvapmdmrdav,dv�R��meprtgseBvrtrm4,prdmwurv4�vo1vMm0egsbIDH-mapwvpmhtgmGvuastmma{. .iw,aawmveazve drudnbGmmmpldulRmmr�kAeb Ovm4mOminAcatlri9vmlW0i4mW�eRm�IdmOLbRdmidFZYero§edP.i TUVFlbib104dN6Jrvdnrimtkb09biLin'4ettba�lCm'ddmihh��( Vnumrwum E.e.ewV Gi,etS mmeypgm dmTm ummmwRmmvmamom+axsd,eaanumueomsbqun^vr;asgpx�dhmdaummv�ampmupunum+nm,p�masma:lavudwumavpiro,sor.R.nD4 mtn,:xnmun,gai F,p1e°a, �a rkmat¢edhveadgd,an.rr�ph�rv+mmw�f.n,tauGu, Fer�isAmarvaarwgwr L;ns�uvyvneonuanm w�voiennmasdom[:.. o„r vsn.cwrs � (v iOt017AiWdtbssei- v IlvmtdO,Pi to m2vdimabindvmmem,ie vrm� Mon a v%Iwyhpivmbae0:dhemee.snuymmudmhvmAlBunmuA,�kiev�pl.ivotom,Pt Jab fuss Truss Type Oty Ply RENAR�MORNINGSIDE MSBM83 CJ1C Comer Jack 6 1.--•-__---�_�Job Refernal . 1 Roof cusses, run rfaf L ,rr., fvuss.cam Kun: 8.2111 s 2x4 = 18 2018 MiTek Industries, Inc. Man Sea 17 11:33:48 2018 Plate Offsets (X Y) - I2:04-0 0-0-41 LOADING(pso SPACING- 2-0-0 CSI. DEFL. in (loc) I/defi L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(L-) 0.00 5 >999 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.03 Vert(CT) 0.00 5 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 2 n/a We BCDL 10.0 Code FBC2017/rP12014 Matrix -MP Weight: 5lb FT= 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- LOAD CASE(S) TOP CHORD Standard Structural wood sheathing directly applied or 0-8-2 oc puriins. BOTCHORD Rigid ceiling directly applied or 10-M oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 0-8-2 except Ql=length) 3=Mechanical. (lb) - Max Hom 2= 36(LC 12) Max Uplift All uplift 100lb or less at joint(s) 3, 2,4 Max Grav All reactions 250 lb or less at joint(s) 3,2,4,2 FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp S; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent Win any other live loads. 3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2, 4, 2. rmv�rYamlrirmu.m•llnairl33 (IDIRyEbilllftl6tfNtiACnam1Y o amm,mrdmR,de� Lmarrfddlam �&im�Cm�nx�mm�� m°`em0�vmo'y4ies,a�.vsapa' .1"'.s"'s war a E'geFO°"°ensfsls I Wmmwn'mm G3mmlmbCp>gfdl A+rUrtf relp.OpnQ fludQejntlrlifcilttllCi�nrtfwc¢(sedmptl,nmdRaMgn9mddrld,minind4n clmsl�lumID4kr delgLh P�¢m, at•63alvdnm,smd5.t. .IamtaOVAap PEexam drnd!?IrtrhepkYvgM1mmrydWftlmA CmO+n'fea4Cdydumm le 4 mlmp MgntlfraWerAtl4vu!.idnmWpGmpbsf olpd lmudrlkdlgrmpIIfdCrlSvmvllNldlutr161 CAtl$xl ltl p>odpda Bampm3UustlYMd4lmfpupe.l mpng4,2egmirm[P3Nntl�tlbr RPWw.FLN9re nermdfodNvaam and ye.iiaFmpus7nmtii mimsOfDa W'nffrtrnnsaxq�w b,ISN.tgyedgwb wwnm{evm Amysm): ou: ovfsrsa,e I' � 0 hIO1AlAA 1[ardimsses- lav Llemtem,li le mdoAm4lhudomge tl lof I Pld➢ Am ) p e4 � m,rsfidbAedvflkmne vimevpnmiimm M1rmld loAlosses-AeRimri.7oahoN,li Job Truss Truss Type nN PlyRENARMORNINGSIDE A0133456 WRMSBMB3 CJ3 Comer Jack 6 1 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 a May 18 2018 MiTek Industries, Inc. Mon Sep 1711:33:48 2018 Page 1 ID:tW YXbtUGW VXBg9MPyEYwl7zgtLu-I5xPKm2Z?R6Eeyl gKQeWyZQSFGIZ3pp_nkYN_ncfYX W2-11-11 2-11-11 2x4 = LOADING(psf) SPACING- 2-041 CSI. DEFL. in (]cc) I/defi Ltd TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) 0.01 4-7 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.12 Vert(CT) -0.01 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 We n/a BCDL 10.0 Code FBC2017frPI2014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-11-11 cc purins. BOTCHORD Rigid ceiling directly applied or 10-0-0 cc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 60/Mechanical 2 = 20110-M (min.0-1-8) 4 = 30/Mechanical Max Hom 2 = 82(LC 12) Max Uplift 3 = -43(LC 12) 2 = -72(LC 8) 4 = -27(LC 9) Max Grav 3 = 60(LC 1) 2 = 201(LC 1) 4 = 49(LC 3) FORCES. (Ib) Max. CompJMax. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 to uplift at joint(s) 3, 2.4. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 1216 FT=10% 6r6rlm,lvrMhmmb'NC@ftrffia(fFllalERd![IaW[fuYINC6d51'utlC�n71tDILTi6LLPiTrmTdi�DRa°vsdM� ovivnWPm�rtn%7dtrlfJQilidlltlmam4�LMw4ilniCa.w Md mG9.a`j I WutmcmrummmmwamiaroY di aru,amsnPv k�WmolMsaanme�«mcmmaarm'mdy-c�nma>4®rmmmpaass}.msey.+.mao.gd,m+.lan4mLLgaam+wwvmoa r�meuo,w�ezew dimdarl4tmnimmghmre�mNlib)Inrt,bOrntr&vvdglemmb>)psly,,ia�aAb6imB rim NEdf?NIed0.L im9,+,Mdm144dnRA,vEMimcGOitm'+ia441M9fmdhMitlammeiry3t'�d NmYrwux r+gnreVtG G91619 4bYxj4?iOndrLL'+Im.Nnsssslv0rhi[OeYmp6v{®/godigs RLeYimlinNm�tjdr°mml�}���d%Mot YflmMvmtlYjmNPia�THhfini 50xMdM�uELLe4Ail im5 dinLLet¢bT uSl Stuee ohs. rOMdapdM(ddryed7rym�Mghdllrm�adiei,TnlmeWpFgin,tlWimrO'4rhtgaclnmSpSaEgmaEmiWm}W��tlmlMummlAdblln. �"gym � �� flne �YA1B� � fv TI D)101611 Walinves- Ivv I.Iv¢Ee1411 pe m7m0vatnbivmmem,m ¢ iel3ilerrdham�er�n eimiEvvhvmAd levlLvs4i�Au5v I.LvddN,PL iP'➢ /m Y P ®JN4�,p 1! yr Job Truss Truss Type Dry Ply RENARMORNINGSIDE RMSBMB3 CJ3A Comer Jack 1 1 A0133457 -, _,_,_ ,_ _ -_ _ Job Reference o ti onal FL 34946, ovsiynBva iuuss.cem nun: e.z1u s May 18 2618 Pnnt: 8.210 s May 18 2018 MiTek Industries, Inc. Mon Sep 17 11:33:49 2018 Page 1 ID:tWYXbtUGW VXBg9MPyEYwl7zgtLu-DHVnX63BmIE5G6cl t891Umyd7g5PoG370O1WXOycIYW -1 4-0 2-11-11 14_0 1 2-11-11 LOADING(psf) SPACING- 2-M Cat. DEFL. in (too) I/deb Ud PLATES GRIP TCLL 20.0 Plate Gdp DOL 1.25 TC 0.18 Vert(LL) -0.00 4-7 >999 360 MT20 2441190 TCDL 7.0 Lumber 1.25 BC 0.08 Vert(CT) -0.01 4-7 >999 240 BCLL 0.0 ,,DO Rep SVess Inor YES WB 0.00 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matdx-MP Weight: 12 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-11-11 oc purins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation aide. REACTIONS. (lb/size) 3 = 60/Mechanical 2 = 20110-8-0 (min. 0-1-8) 4 = 29/Mechanical Max Horz 2 = 82(LC 12) Max Uplift 3 = -46(LC 12) 2 = -56(LC 12) Max Grav 3 = 60(LC 1) 2 = 201(LC 1) 4 = 50(LC 3) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify rapacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. LOAD CASE(S) Standard rcp.n,a„earryrnc.a•nlw lrcut(wuicmitrtasw+ennpsrm¢sl'¢mlBiocse'rarma.l;hmaar�"dml.v,mmnwm,s,u..aalikjdalnartm:saaiiB�aanm�,,. mwaa and am,.�ry ' g5B<YYVORBdMm66WabIBBYb,dd1 4rtBByq+m� Qa�ytlNlhrz+}fliu9 glBBryrtvabvrtB'uvCardn9v�yrtLhnA�mm/aam�pdbsejeNSMralwalCBdrtl IM AeCcywepetµb6xrmmivavndmp �anuemmuvveatem dmdlBUutrNHYaikainl,ntlallbautbO+arbASCdLVealWah+%Bmwwia BCaCdai]bYgared0.L a9AWda144daE,Y dotruemottY$aiRnb9CaadYavyvlflbanRs*ii%d, ups, Hlue, &�W�uG9i6f5 a Wz+BBeyv�d fmra lAeNdal bllmdapomeimlpndwdd,magfvrxv'1.%k4s^ualBlryhlPodBxa nmmltirndPda¢1Mm4Bb,rymdEttacgOdi641Nhupr.l�vsMq&pumv{InuMafstiunHi Ft Weru.R9Bsb aSii�vldWkB4xaaWN5v4�+69h@ppuFtl�tl.RlwMJr9®nNtalelaib+rv,vinivfRa&gLvdmrldiR Ngtluia�unmkMmml. om oanirzB�a � ( DI®7➢IDgIIBrJfnsseB- IBB LTeaieiq r.E to mgBO�Bvale'u2Baven le rypig /,m 1 p vo/fwryiBpio13i1edrilhomtlevmleepe�m'uun6omA-1 looi rotas AtRivorl.lBmtom,gi Job Truss Truss Type City MORNINGSIDE WRMSBMB3 CJ3B Corner Jack [lY 1 1 �RENAR A0133458 Job Reference (optTonal A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Mon Sep 1711:33:49 2018 Pagel ID:tWYXbtUGW VXBg9MPyEYwl7zgtLu-DHVnX63BmIE5G6clt891Umyetg4V0G3700lwXOy.dm 2-11-11 2-11-11 6.00 f 12 T1 1 Io 3.00 Fl2 3x4 s LOADING(psf) SPACING- 2-M CSI. DEFL, in (too) War L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.13 Vert(LL) 0.01 3-6 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.14 Vert(CT) -0.01 3-6 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 2 We n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or2-11-11 oc pudins. BOTCHORD Rigid calling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be Installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 108/0-M (min.0-1-8) 2 = 69/Mechanical 3 = 39/Mechanical Max Horz 1 = 59(LC 12) Max Uplift 1 = -14(LC 12) 2 = -50(1-C 12) 3 = -l(LC 12) Max Grav 1 = 108(LC 1) 2 = 69(LC 1) 3 = 52(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.0psf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load noncancument with any other live loads. 3) a This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 1 considers parallel to grain value using ANSI?PI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to. bearing plate capable of withstanding 100lb uplift at joint(s) 1, 2, 3. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 10 lb FT=10% r<+a im�emprrm.matmrmm�(w�iaE@[nunemt-mm�ipY('TutOjl(11CflYJarlmietll6Hr�*9t��d,del!�eCutm�9-0kn41@�id6llaarLle�BlllrGem9,61d2m0W Caw0M kiW:ali ' WrgmmntmQmhemmmmnn,d:@e ume�9r W 5�nupx�>rmuenm..gnm�ss.ogeaamraRu.deyore.+s wa�a�mamwi rmsro+evmmoegmPmtw m'mmm.+frx,ral�moc,nvaar. .�eo:.:mremme [de{,IIVIjM1ll$(QfrNtgk4lMryd'nQmydl,m@ 4�aQilRxLmmk§BelfreV/@.e6E611m6I.MB.�lmhm{..YOII,4P21M1L1bpptltlllmlDA0IPSetlmQm{lex,k611�'L>L506A�a®dYmrtd�Mmm{�esrBft E:, l4To�e Horse FnGe:eennGG61615 mhumr?psedreCeaxllmMWe6�hlABdmpvtieiolp@Qm"FD�rNml@9?m�6lL'xe'mP�PV�6,BINel4lm�tluemlhlmmP✓a-1M1IGA¢�b±nMBJ.4t¢�a3iQ&Irm0Wa.1rmtr14e9ea?rMtMaGme:MII RRew,RNN6 efe:tlulAvd{ya44goydgul•iemghml�el dd.9YeimspYn(gxmulNb4Qy+ileiA Ne�ir�en[pBnfrgpNry Naptiv�ta mmidmlvibd. om: vsnsnaep � G i M697@Idd�l Ivdtnsses-Av@ L1Bmdelb Pi 1e mdedvevl@blvmme m h a olid'k xvhPmihe QNnv ei®mvvhvcAl tvelpnu Avnv LivviBalll,lE Jeb Truss TmssType Oty Ply RENARMORNINGSIDE WRMSBMB3 CJS Comer Jack 2 1 A0133459 _ ., � - - -^ Job Reference o tlonal A , Reel T.uases, roe, rick., r, .wnrw, wesiyntwa iwss.mm nun: e.[1U s May 18 2018 Prmt: 8.210 s May 18 2018 MiTek Industries, Inc. Mon Sep 17 11:33:50 2018 Page 1 ID:tW YXbtUG W VXBg9MPyEYwl7zgtLu-hT39kS4pX2MytGBDRrg_-1_Mu30HXjJHE21 U3ryclYV -1-4-0 4-11-11 1: 4-11-11 i 2x4 = 411-YI LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.36 Vert(LL) 0.04 4-7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.29 Vert(CT) -0.05 4-7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 18 Ib FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or4-11-11 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 112/Mechanical 2 = 268/0-M (min. 0-1-8) 4 = 59/Mechanical Max Harz 2 = 123(LC 12) Max Uplift 3 = -80(LC 12) 2 = -69(LC 12) Max Grav 3 = 112(LC 1) 2 = 268(LC 1) 4 = 88(LC 3) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 Woe will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joints) 3, 2. LOAD CASE(S) Standard m,q.i0um.{hm�nk-n mrnmo(rum'js[vuo-tiav[rmmnarmruYr¢+G7wrcrsv[imbcte;hkwp�^,d,��Pm! m+vso4frtL:Id Y4tntto--i,Ritle.,osWMnw ai„e=.=ma Ylw,my ' Y+Irtivonlbntr4Ym1Yb1ePY,tlaY umlapnsalnG W�tlnhm4YWv eiWBrzpumtpme5mtlhytln�bdiG�¢'bingmPOq$Y4�pd4�pjlnvdryUauYlE9nMtl WLibinpnnrFMµh#m�m0on;attr9p due�BP.um PEeHOs dwdu/nuaml+¢vxYn�aPnAeYamcao..h.8xeaviJrYldc;Y;'i'., Ymraamo[.YxaYmatCsynxeJou.n.v�ntlammevaemA namm,t"�+4hAyfaw ncYYmmt�kauasY�Na ww.Hwxe�ovwwiv c.s,eis Y WqA gmalfranteUSY,f.W.YL9dbp6a�ol�l�nnRYklEgfealamY,rypxs.@10PtldtlplRd&JneEvmlYpmtl9°Y�1M1�hh,Y�ryefJra,ifranEYl at Imi '4^,xnmrw YmGa4virt �1p110°�• vMlbdto9h(miawd5:ei�ahmmY,Lmntmlmvnvp fgareumi mu$l�Pv.lans mr mmivarmmmdrmnmr � ?gym. nPmn. Ftavw6 rgvrg mYd1n osn: oansrzv,e GpyrigM0P01611 fvv11mssesAnlavyii aMigl.0 kpmlaG�m Alhutomcvm,. ov pbm,6yio03kpwd0avllYreOeepemiiuvehonll HvdLniel�HmGovyltvotom,pE Job Truss Truss Type Otv Ply RENARMORNINGSIDE WRMSBMB3 CJSA Comer Jack 1 1 A0133460 Job Reference (optional) A-1 Roof Trusses, Fort Pierre, FL 34946, design@aibuss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Mon Sep 1711:33:50 2018 Page 1 ID:tINYXbtUGWVXBg9MPyEYwi7zgtLu-hT39kS4pX2MytGBDRrg_7_VkT3NmXjJHE21 U3NcIYv -1-4-0 4-11-11 1-4-0 F 4-11-11 6.00 ri2 30 3.00 12 LOADING(psf) SPACING- 2-0-0 Cat. DEFL in (loc) Udefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.39 Vert(LL) 0.05 4-7 >999 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.33 Vert(CT) -0.05 4-7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.01 3 n/a n/a BCDL 10.0 Code FBC2017/FP12014 Matrix -MP Weight: 18 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or4-11-11 oc pudins. BOTCHORD Rigid ceiling directly applied or 6-D-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation uide. REACTIONS. (lb/size) 3 = 113/10echanical 2 = 268/0-8-0 (min. 0-1-8) 4 = 58/Mechanical Max Hom 2 = 123(LC 12) Max Uplift 3 = -83(LC 12) 2 = -65(LC 12) Max Grav 3 = 113(LC 1) 2 = 268(LC 1) 4 = 88(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult-160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 2 considers parallel to grain value using ANSI/rPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. LOAD CASE(S) Standard riWl bmbmiN{xMb'N11pF a'8R(xlla'lra9ltltYitfOhU1416a41W f&1RjltlruS.a',eai`rac idt6�4 Pm'�^selrtilmrt�0stade'A&n9(Ifgdblmryti¢bRitltivert4�dlhere. dbxede.iomdeblfv.s} Wi,lhm:n�l!mil4MeMb6+t000Y aynl,veyaP �p yaag6p�Y4vW ollE6npa,a<nemjmibFtlrtmde�4�N5rtTs�Ih:b4ye94uAeMsMUtivO,NCe�1FA+IPA NCtRnvRa4?�iM"+w4Wt@I Jerimetenim vEemae tlmtllYlw4NliYyxlhmy+P$LRd0i0irN.tiMe,ieSmtdY-'IYb1W]9Ce�a,ltro00tlb0EGCWCeWdAMVIde�sll NbnrtdYi4vdtrGll n6l�tosstlCiEf,%ri�d lehASmeihAgYAYbngalWd A!eQO�jltl wmxxa Fneneen.eG9iss5 uS�stYW QedYq; 6Yym"df�a,e NabbWl9149 Jb PW'¢sa1P� rt44YhlruMmldryPb+2u N9:Id�Waih�ld➢flmNees1i Vlltbt ilx 4d16N.0LLwp9P.i,ub mlfvurif5ovv.lal PTtlPi>e 4nYes i'?a=, Rawe,R3iiK NaeN(dudlrenflpeynlWLndWMd)Ni+6�artLin1ms64PeWx,hINb1YW 11,IIS�iIQhpdprLedi{1�,WYlLLlhitNUi�tlY1rLI. OW: 4M.VM1B 14 Gppi➢310706AIWvlinsus�Amly y1.lartdellAl2 0.epmdvEiveAtdblvmmees,iorv�lvm,rsPivG3Eed�ulpmidlrsmtepesmuwvhveAllvdLesus, AnEvvyi 7 minN,Pi Truss Truss Type Dry Ply �Job WRMSBMB3 CJ5B Comer Jack 1 1 �RENARMCIRNINGSIDE A0133461 �_____ ��,____ �, �,_,� ,__._�.,. _ Job Reference (optional) nwi D msses, rwr Pierce, FL 34946, ues9n@a Ivuss.com Hun: 0.210 s May 18 2018 Print: 8.210 s May 18 2018 MTek Industries, Inc. Mon Sep 17 11:33:51 2018 Page 1 ID:tWYXbtUGW VXBggMPyEYwl7zgtLu-9gdXyo5RIMUpVQmP7ZBDaB2vkTiuGAYOTinl bHyclYU 3x4 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (Joe) Well L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.42 Vert(LL) 0.06 3-6 >993 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.40 Vert(CT) -0.06 3-6 >977 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.01 2 n/a n/a BCDL 10.0 Code FBC2017frP12014 Matrix -MP Weight: 16 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or4-11-11 oc pudins. BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 182/0-8-0 (min. 0-1-8) 2 = 118/1vechanical 3 = 63/Mechanical Max Horz 1 = 100(LC 12) Max Uplift 1 = -26(LC 12) 2 = -86(LC 12) Max Grav 1 = 182(LC 1) 2 = 118(LC 1) 3 = 89(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 fib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcumtmt with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 1 considers parallel to grain value using ANSIRPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 2. LOAD CASE(S) Standard barimla,ylhl a.m•u im nmczr�rWriumevmanrturmrurdlsluucco�ml..lb+ril7P�m+dai.mmmu,,,mvb+vwlmQde+lmrlam4rilaomrdab.0 rnm+me,baaaaui, ry _ I WnlluctulkaJflWmlbma0pYN4drUmllvphpurN.xnvry5pb}afwl mmnnrnslmrm/wamlulnmdgsrtmbnavopltrmtumloeWeMstrymlummomp .awtalmTmuG�nuawa+mw,cump. .welamiwmaeszeoa dmabsdua Ie�LykmrtirneP�fmmW,mO+aitrlaEAWHamW>!Ov'N,.bbmuadmYCmCnlb MldmAdedutmq,,d4smodgmAUlealm+s�7moa mubmo.i�mallmm>�rrp x+w.x�,. mrmmwwe.seu truvgvsprdmmmcuvamN blf9clmba@Iafpiyvn0mwy(r�pmSE1lga.^ull�ludehmdva.tQvmlYrmYpia21MC3iNrryepl61ltlg6itaLubuye.l�rsiki4WR'v�iimraMav�eM RPwuR>a�9w • Iaa.w tfWF.uvaod,pmG+�rwhepanmm�a;tm,GLi lgamgrotmlllflW+>ta„ tin+fnaetipgemaas; aroclmie ROtbybRV1. meb: 0L152018 (vppnpb®7816AIAvilinsses-Amly /I.iomhe N.r.! eepmdvSvv<Ilhidvmgev{ivv�fvrQlpFvA3ue0aukolthevrmtvy<rmiliivvhvmA7Wdimu;�Ae@vvri.lvvluN,ri Job Truss Truss Type Dty Plv A0133462 WRMSBM83 D03G Hip Girder 1 1 �RENARIVIORNINGSIDE Job Reference (optiona0 Run: 8.210 s Mav 18 2018 Print: 8.210 s Mav 182018 MiTek Inc. Mon See 17 11:33:51 2018 A-1 Roof Trusses, Fort Pierce, FL 34946. design@aitruss.com 16 1.Sx4 II N 6 3x4 = 5-0-0 8-6-10 13.6-10 3x4 = 5-0-0 ~ 3-6-10 1 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Vdefl L/d PLATES GRIP TCLL 20.0 Plate Gdp DOL 1.25 TC 0.33 Vert(LL) 0.08 7-14 >999 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.46 Vert(CT) -0.09 7-14 >999 240 BCLL 0.0 • Rep Stress Incr NO WB 0.15 Horz(CT) 0.03 5 n/a We BCDL 10.0 Code FBC2017frPI2014 Matrix -MS Weight: 54 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or4-6-6 oc pudins. BOTCHORD Rigid ceiling directly applied or 6-8-10 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 901/0-8-0 (min.0-1.8) 5 = 901/0-M (min.0-1-8) Max Horz 2 = -52(1-C 6) Max Uplift 2 = -497(LC 4) 5 = -517(LC 4) Max Grav 2 = 901(LC 1) 5 = 901(LC 1) FORCES. (lb) Max. Comp.IMax. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-1469/917, 3-15=1284/841, 4-15=1284/841, 4-5=1469/898 BOTCHORD 2-8=-740/1265, 8-16=753/1284, 7-16=-753/1284, 5-7=-741/1265 WEBS 3-8=-224/387, 4-7=200/387 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 par bottom chord live load nonconcument with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift at joint(s) except at --lb) 2=497, 5=517. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated Ioad(s)106 lb down and 138lb up at 5-0-0, and 59lb down and 86 lb up at 6-9-5, and 106 lb down and 138 lb up at 8-6-10 on top chord, and 215 lb down and 213 lb up at 5-0-0, and 48 lb down and 68 lb up at 6-9-5, and 215 lb down and 213 lb up at 8-5-14 on bottom chord. The design/selection of such connection device(s) is the responsibility,of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (pli) Vert: 1-3=-54, 3-4=-54, 4-6=-54, 9-12=20 Concentrated Loads (lb) Vert: 3=59(13) 4=59(B) 8=-215(B) 7=-215(B) 15=59(13)16=-39(B) M1vqIm,mx,vrlrmurmYlnvflr�(fN�i!<J3fQWSrGinnW f04YrSAa1 WCria:rErl'bn ieeriil}ransndmim smvUwOsymrq�dbLmart4d,41211�mmlliseea PJui�mv0daml®,ay WlekmvwRmmgm,almpmmM 1r. P+v,I,n,PwpfrywuPs:xwnryh}xvflewl wna,weemrmmlmdmp&,N,fgenmregmLRr4mWinimuj,ims Nrm#wmR4a�eMslRim Mpw�si+u,YatpoEmatW9a' euvemeNwvEsmoa .9w,neµ7rmY mWwem,�ryWqnmownma.;riwecea4grmmkN?�w.he®enmamemlmtatmpnadatlbaxmrdmtwmw.mAiammwmsitrr+aum tmemdY.wYntmmw�.maanr .a�'s,g�e. w""��°c•srn,s mwrijm»<sdrmia.m.mwr.auodmPemlap�'nmLuaytym�,vpwww(mtpmahadmgvmadnmPwraaatnra6gim,wmre: zmraunmu.spe�..aws?nytiy�dr�.wr�onsan I� ew„�e,a9 rsaHehpAkr4n+ariwl5wiiinYrhmFm+iwnliMtms&va r9�mneatdlnWWw,wmafl4aNrynnmlm�l Nml�3nm mltldnlRt. om Mnmo / � (vgryghl®7gllg llvvtinaer�Mlhv i.ivmhv0,Pi le Aenda6dvmne wmgio P �J % pwW vy' ,m,k ioM13gep.vhanWnimvye,mnpvaM1aviAl WNinuei Aennvrt.Tvntogl,Pi Job Truss Truss Type Dty Plv WRMSBMB3 D04 Common 1 1 �RENARMORNINGSIDE A0133463 Job Reference (optional) ••....•••..++...•.•..•..•...•.....�..�..+..........y•Va•uum.we, nwLo.clVJ mGy..z... farmO.cIUS May 10 Nle Ml I eK Inausmes, inc. man Sep l l l l:J3:oz zu io 4x6 = U 3x4 = 1.Sx4 11 3x4 = LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deb L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.70 Vert(LL) 0.18 6-12 >911 360 TCDL 7.0 Lumber DOL 1.25 BC 0.61 Vert(CT) 0.15 6-12 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.14 Horz(CT) -0.01 4 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-10-4 oc puriins. BOT CHORD Rigid ceiling directly applied or 5-6-7 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 577/0-8-0 (min. 0.1-8) 4 = 57710-8-0 (min. 0-1-8) Max Horz 2 = -67(LC 10) Max Uplift 2 = -222(LC 8) 4 = -245(LC 8) Max Grav 2 = 577(LC 1) 4 = 577(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-702/1132, 34=-702/1132 BOTCHORD 2-6=-842/564, 4-6=842/564 WEBS 3-6=577/312 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult-166mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; End., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; and vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at --lb) 2=222, 4=245. LOAD CASE(S) Standard i PLATES GRIP MT20 2441190 Weight: 521b FT=10% fclq.lYrvprtry.}lmrb'HILttaRa(01RySEEiillalBE�Cil6n�1Y11�E°.a1lWl1".FZJfRbc l¢YrY4prmtlmtlMdnsautim0erpiuYyliNjdb4xayL1aL411WP,m9al1(n to pbt� 0.1JohAf.aj Ellelm4ellkcil9q Ibblpltk M4 baNUAsipf 44.5lu�46mejMw erlknlpmlmm�baAh PMvaL�9�a'Mn9.dtlg4�d4glAbta'I. NnLyUdu4llgeEPd iei PahtpmnalEly,k3alyl0eletuerl9'I dmEONbukWbY�ikbmlzhA6b0aRYE+eitieBPEtlel1[EeIXa16u4T.EhoGEtlb .Iare,BMnIap PEetm9 BC0t8 d6t61bAhr�lvmla4t lb9lMd1104dwNIlCMImLtiGlmdeiiaT.Ma9SndNe'il0.�hbn4+t01%(d. A!!, exvlexau eanwmOG918t5 bbQrpKjsdfQY.NY04tEM tilWdhlalatvllLLloiitlkYl6gfrs{amWppv9�ip6Ep36vW7Wd1UJ®KxmlYlytlldme9HC!aitbinpmAl+sal40ti(bt tbupr.lmvpugetvymmilm[Mitlmµs4n jup'�nV,R�N'e t!veryliodMe44HeyalyLOn0gledrNJCdirL1911n kYl6legklClhlSlpkaTa,elnu Sp4a[ghmEWYi4y NgYWdk0O1013e1YRV1. Ome 6NS2N9 Oppi91101IIIA lIeolTnsseseEvtl Pl.lwcle N, P.0 [epmduaioe Aflu/ompevAinEo)Ivm,up,oflL'eelrpbCNlEeremeeyeilii"ssrovhomAl WetLvnt[ AertovrLiomEoN,Pi Job Truss Truss Type aty Ply RENAR MORN INGSIDE A01334B4 WRMSBMB3 D05 Common 1 1 Job Reference o 8onal A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Mon Sep 1711:33:52 2018 4x6 = 3x4 = 1.Sx4 II 314 = 6-&5 6-7-15 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) 1/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.70 Vert(LL) 0.18 5-11 >915 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.62 Veri(CT) 0.15 5-11 >999 240 BCLL 0.0 Rep Stress lncr YES WB 0.14 Horz(CT) 0.01 4 n/a nla BCDL 10.0 Code FBC2017ITP12014 Matrix -MS Weight: 50 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-1(14 oc purins. BOT CHORD Rigid calling directly applied or 5-4-7 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 4 = 493/0-6-4 (min. 0-1-8) 2 = 57710-8-0 (min. 0-1-8) Max Horz 2 = 75(LC 12) Max Uplift 4 = -224(LC 8) 2 = -222(LC 8) Max Grav 4 = 493(LC 1) 2 = 577(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=701/1136, 3-4=70111137 BOTCHORD 2-5=894/563, 4-5=-894/563 WEBS 3-5=-580/309 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed; end vertical left exposed; porch left exposed;C-C for members and forces S MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in, all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100,lb uplift at joint(s) except (jt=lb) 4=224. 2=222. LOAD CASE(S) Standard m*y rYu, nagnmv.d�'Hif affia(two.cacti®svmanrtnonm�romr7wmr.[@:umun.ieesas�s»masr�3:ms mUmo g�do.q(ncjdal�ttafva2wemske�fix,.u.rtm c.+aoad mlCa,.k I wsamo.pmsvmasrmaioeatrrAs euwoup�rW lwmrsFmraea vnmamsm�em�aas,as,mi4+n'nvu�vtrrtrax,aaasd asMm.amMwrtu.uaaxv:nq^m�wwmu,raaeq .wreumwrevzam m.unt,M1i 6:mP,0enaartsumemo.wau..tee=edsT�.mrdaiW9m.ma,maaae[.mrvlmfimkand,re 0.lmai�nam�oamwmr,o6atn+c!eC4ltmss.m.w9meldsdia94a°4�6Eea vw.iw»e,ar..w c�sisys ata�Mgv,ey cram.vvuussnraamorayvmvsm�0nnamngtmlwms,msKsum,�'sttirgmmvueeswmaYpmpi.o. vNatisas�dtvtdfpwapi sGup..tmiouyiTs$ asrouaxm.oia�si a�N�y,m rb�,ml6adHr4tErF�e�6�tmgfialpr$�rtLllelwsku/r¢sl:iOibJa'1y H�pe,etinlm�bpaamrMdiry WoatlxiMrndddlaFl,. Ove 48nY6r9 � (v �®7AIdA 71v97rvssn�Anlev L1vmEv0l,Pi Iv mdoAinaltlisdvmm iv fv FIaBb P F v4 vry m,islSvLl'Aedmnbpmae vnueejvimhsiovfivm Al Hvdrivsies�ApAvvri:remlol4Pl Job Truss Truss Type DN PIY WRMSEIME3 EOISGE Common Structural Gable 1 1 �RENARMCRNINGSIDE A0133465 Job Reference o tlonal A-1 Roof Trusses, Fort Pierce, FL 34946, design@altiuss.com 4x4 = 8.210 s May 18 2018 MiTek Industries, Inc. Mon Sep 17 13:28:40 2018 3.611 3xa II LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.31 Val t(LL) 0.02 6-7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.18 Vert(CT) -0.01 6-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.09 Horz(CT) -0.00 6 n/a n/a BCDL 10.0 Code FBC20171TP12014 Matrix -MP Weight: 46 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except end verticals. BOTCHORD Rigid ceiling directly applied or 10-M oc bracing. MiTek recommends that Stabilizers and required cross bracing be Installed during truss erection, in accordanoe with Stabilizer Installation auide. REACTIONS. (lb/size) 8 = 340/0-3-8 (min. 0-1-8) 6 = 340/0.9-8 (min. 0-1-8) Max Horz 8 = 73(LC 11) Max Uplift 8 = -137(LC 8) 6 = -137(LC 9) Max Grav 8 = 340(LC 1) 6 = 340(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=-263/488, 3-4=263/488, 2-8=311/545, 4-6=311/545 WEBS 2-7=-3041195,4-7=304/195 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI?PI 1. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live oads. 6) m This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=1b) 8=137, 6=137. LOAD CASE(S) Standard iv@,Sll,nelv,q!I�mtlrb'IIrWFIIEfn(fW�S �illiBllf{fpCil$nOSIpY[tlt]jlfn45'3Jarbe 4ri4dPNmsmd,r4npftl1, ra ltlnm0erb@Nnbiq,ntf kWWffi,y�It;dbl . n%100.al.,9ai!! nno9a@MpYn,Ytl„emNn4muimrkhenM@hsgf �"^tlirm@Dar epr.$ch.bkw, l''b'1 Wb@fitdbh,6due .hrn9Ml�PEORm k"..41nO M.dn 'N 0..6 WdNTrn@,1Wnh.deALL,6lpfnnaA�.�n'ai rprnb MYag Mmm.vbMYtlbItl.YA:dbtJHlhSded3Lt lb�m,Ltlbi40da6tlmtlbrmrvlC_d=Nn'Rtl+fYaaf6u4ilChbnV+WlO@ W�,aexwm E.gnoe@mu9te,s fttA'fSmtbglmLLynbrtipdtim@bOrm.bPNfc*acd \\ bbp9b'dfweu NnnmwmbTJlelbimm,afp�ftlbLEfprm}ay1@eglbmme(InAplle4lhlgNllnveNvmlbpeNp@sP.IkruYm{rmltlmestli@a@GLn, O,upv.lmf EnpryvnW lmtra4ovµelm �f me1OeB�• tt>are.Rsmrn l/■ eLmAShcirfar@rydgtlmemgqmlwnmtlnl hims hux�6r4fb ICv4ne mSh3AA W� taYylga,rtrnni tl a ddermmtllhdminl. mu: ONYMm • 6ppi1M 0 MIA 1 bdlasses-Adhaq T.T. dolq P.l.Aepadaaiadollhisdomoem,mvgiwWispwEiOueduffidulMe eimeapersisGodfivmA-I PadLnserMEvvrr.7amEo N,Pi Job Truss Truss Type OtY PIY WRMSBMB3 EO2 Common 1 1 �RENARMORNJNGSIDE AO133406 Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com 6.00 12 5.6 4 300 11 3x4 = 18 2018 MiTek Industries, Inc. Mon Sep 17 13:29:12 2018 Page 1 EYw17zgtLu-09JyWe rkOrSpJ1 MZxbsDahBekNgxMKwBy_otodycjsL 5x6 C 5 3x10 11 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.51 Vert(LL) 0.16 10-14 >595 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.41 Vert(CT) 0.1310-14 >707 240 r BCLL 0.0 • Rep Stress lncr YES WB 0.00 Horz(CT) -0.03 2 n/a n/a BCDL 10.0 Code FBC2017j TP12014 Matrix -MP Weight: 371b FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 SLIDER Left 2x8 SP 2400F 1.8E 1-6-0, Right 2x8 SP 2400F 1.8E 1-6-0 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 34310-3-8 (min. 0-1-8) 6 = 34310-3-8 (min. 0-1-8) Max Horz 2 = 40(LC 11) Max Uplift 2 = -140(LC 9) 6 = -140(LC 8) Max Grev 2 = 343(LC 1) 6 = 343(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-402/832, 3-4=198/369, 4-5=-198/369, 5-6=-402/832 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift at joint(s) except at --lb) 2=140. 6=140. LOAD CASE(S) Standard c.mpre.emrwr�n.n.m•kiuorn�l'sniat�uiuss.lommoarmlaMc'1PMmoc�eui•om mhaww=mmdrwm.msummoev.nlnDcmmxwrl.l mnulrmmnwua.. e+.smv.rmrrmminaabry MlfRmsvrh4Y£4rvImb10iBYKi b.[r Miplruepyyra$4¢?bW oglprtpbe5empu6mr�.�9=m% rl'$bmlupibsejelnutgvdnmtaq.dviM1lbMpwroFm Yigaalvl+�1$ JmwBP. rtlenterlretYmlelm9lsbrulartimlmpwtm OruirebNdyJvmmbypn¢m,.mwvetlmvCmxdOeFdkYsia4d0.1. nsPArNfmlOBdmfiJlnr6mimeYA�9M93; R'9sv90Rmdh®iYLldmu+p+90eli knob xousaergneenN Cn9,er9 Enpc" u516ttua mgY9lukaalfram. Nab NiYblfAdmF+msorP.b!56mtrttgfe9�%drAmveAsnR.'MIIOYEI IIdffiAmNuwfYP�dPda¢R,IYEitmrtrymlf er,sliM@44nipul..irmtEe4rrN.WlwYminq.6u R���� r.aaulddlf.�TdRa.r�mghd�lofaartlrH lMlnuk mrL101h1 4u up lq 41y qn,«Ima1n.4�BarwBry amtetloiauwmlNdmnN, oenszvry om: U. . (eppiltl09016A�I lvvl7esms�Am6mr1.7vmE111i, P.E. @pmdvNav otaisdvmmem,iv milwm,isprvE3NdaiiAvmMnmtt.permevivetrvm Ml lvol7mses�Av%vvri.ivmly N, P1 Job Truss Truss Type arty Ply RENARMORNINGSIDE WRMSBMB3 HJ2 Diagonal Hip Girder 2 1 AO133467 Job Reference o Bonal A-1 Roof Trusses, Fort Pierce, FL 34946, design@attruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek industries, Inc. Mon Sep 17 1 LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.25 Vert(LL) 0.01 4-7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.14 Vert(CT) -0.01 4-7 >999 240 BCLL 0.0 Rep Stress Incr NO WE 0.00 Horz(CT) 0.00 2 We n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 12 lb FT=10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-9-3 oc pudins. BOTCHORD Rigid ceiling directly applied or 10-M oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installatlon aide. REACTIONS. (Ib/size) 3 = 45/Mechanical 2 = 242/0-10-15 (min. 0-1-8) 4 = 18/Mechanical Max Horz 2 = 80(LC 4) Max Uplift 3 = -2(LC 9) 2 = -127(LC 4) 4 = -15(LC 19) Max Grav 3 = 47(LC 24) 2 = 242(LC 1) 4 = 63(LC 22) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat. It; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable studs spaced at 2-0-0 oc. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4 except Qt=lb) 2=127. 6) Hanger(s) or other connection devices) shall be provided sufficient to support concentrated load(s) 75 Ib down and 59 lb up at 1-4-9, and 75 lb down and 59 lb up at 1-4-9 on top chord, and 24 lb down and 34 lb up at 1-4-9, and 24 lb down and 34 lb up at 1.4-9 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Incre2se=1.25 Uniform Loads (pit) Vert: 1-3=-54,4-5=-20 rami.lue,pauprmne,'He0f �v9af�arlr¢u:OfiHttO®I'rb®i1;y(6iSI W'rpi.Q'SFRbr, ICAtMgpmntd�d,ttomiln6Mphtvgll[t)dYlaafl lcSRltW«m.LL�LiMumW, Csnnmtl MPA.m'i Wietmraplbwv9d,WbYRJ¢Mkih lmOoPfrynePu.�n4luayst�tlogibn♦mWvu4Yx,tldOtlnmrdytmrprtyvlJOCkb4tptlPeuj lnst{n/wLID4w},tleIWL1Y1,ynuspM61,@ryYdeu�uNlw'1. ✓a�apuu�vEetBm da,tl014iulrtvlk'Orhbrt,�tld O.w.YO.rtiidamdgfuYr�l4npcah,aatlp R.O,CvlbebilmKervndP.l N,rrn,dd6100dvabJ,tl,rws�t�$s,F.Wvvaawlheii6ihhrtgau'i^Id. wmei�uee E+gtreaxv Gd,6t5 YCkq&.gntlevEC LIwmMW�Ylndbrem¢tvf Fltl>ydv�kWfct�ID�viG4evwl®:Id�@JE<IVIm1IDImMumNYlen P�vWIhM1u4mpa#12,tifbBiEbiad,tpelmi4nPvipa?vf rmtkM�vsl¢t tttrvsu,R�we ,tanul dlnusmiyWypnurtrtvl4dfemzt^liH.RotMzWrl[gsmhloihipYq Mn{nvlmtSivvaSamlvrYdSry NvpgaJem mfbdetttl. vm: oau5rzote � (0 3i®1�IlAI[aelfiosses- pyrit Aminryl.IamEr N,ri tep,odvtfiordnniommem,mvrMm,dpioh3Gele>eeNl9errinreyewisswvhomdlYooliivfsn_AeRov9i.lomtom,PL Job - Truss Truss Type aty NGSIDE WRMSBMB3 HJ3 Diagonal Hip Girder 2 A0133468 =Refemnw Jobnal A-i R i i ruses, For[ Fierce, rL 89 U, oeslgnLoal wss.com Hun: U.Liu s May 18 MITek Industries, Inc. Mon LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (loc) I/dell L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.15 Vert(LL) 0.00 8 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.03 Vert(CT) 0.00 8 >999 240 BCLL 0.0 Rep Stress Ina NO WB 0.00 Horz(CT) 0.00 2 We n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP Weight: 7lb FT=10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 1-4-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 1040-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 169/0-M (min. 0-1-8) 5 = -16/Mechanical 3 = 211vlechanical Max Horz 2 = 47(LC 8) Max Uplift 2 = -82(LC 4) 5 = -32(LC 19) 3 = -8(LC 8) Max Gmv 2 = 169(LC 1) 5 = 36(LC 22) 3 = 17(LC 22) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joints) 2, 5, 3. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 32 lb down and 52 lb up at 0-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=54, 3-4=-14, 5-6=-20 Concentrated Loads (lb) Vert: 9=21(F) mvtlnY 0amydlmX h'4llxtlrR6(SWR}Witn90rNhM14e6SIW�-iWRIlmI0410�drfan4"h4YPpeu4ndidLMXtrimfDSRdm9lM1rjdhl@alAlr3�ru11Avea4mlYn 01uv;�ns9EimleM tlj �ipXXr:ielbts]akalbhmYYmM.b Y,XMryhyxQe:SpE(s'avihudmggunpmepmmp adh P�Xnln9mimyauR(OCMes�mPLtgNG,s4mXwblWfft iXbR ep�4YJgntlem4s6tltC1: .we BgmLro PE azem I NroRW4KtrmIH'9ghhmlad�Ftl0e0+w.ti0.mYrA.Ed4Le0ervbnfBuWxYh,bWtlhe.b9:WWfitlbYsiWov3 YLL IleWmtldtle109o1mLle Oh IwcNEYttY I+1ia'eRIDimaadiMu3L41Nhn4NMU vFot Wuee rMiree,Ine G9f6is hhY6Jh$mmlGmm,SNmOrirfWnhi[gmlhpmmsolPXtl?dph1�5e14a1+°nS�Mr'9mupmyldW41(rM�fAa rlumlb'mm�Ptm IM1IXRrti+N=drm�etlP7s@yt fM�X.lutr XNSWtlmbmvnm�m �� ussswoe am, FLNa,FL]Ifil6 NellndruPere411gx1,pYneyAldl)NIpKRLRLIP4 XIm4h hvgFq+m Hglmlm,XNXSPnvfpXrrmple9#ry Wopm�YmmmdacimtM17. mmm oaXno+Y � fvpPiA3SO.E04A�I lvvfrnsies-Amdavyi.7vmdv11L1.E lepmdv?meaird'u dmpmel,mvvJfmryi}piol3kAr�eNlEemritlenpevmuvvvhvmAlkotiiiru'S; IvAvmpl.7emtom,PE Job Truss Truss Type Oty Plv RENAR MORN INGSIDE WRMSBMB3 HJ4 Diagonal Hip Girder 2 1 A0133469 Job Reference (optional) A-1 Root Trusses, Fort Pierce, FL 34946, eesign@alrruss.mm Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MITek Industries, Inc. Mon Sep 1711:33:55 2018 Page 1 ID:tWYXbtUGW VXBg9MPyEYwl7zgtlu-2Rs2o98yMb_F_14AEOGgk1CfY47_C_YOOKIFk2yclY0 -1-5-5 4-3-5 15.5 ~ 435 2x4 = 43-5 LOADING(psf) SPACING- 2-0-0 CS]. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) -0.01 4-7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.13 Vert(CT) -0.02 4-7 >999 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/iP12014 Matrix -MP Weight: 16 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-3-5 oc purins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 85/Mechanical 2 = 184/0-8-8 (min. 0-1-B) 4 = 38/Mechanical Max Horz 2 = 102(LC 26) Max Uplift 3 = -68(LC 8) 2 = -103(LC 8) Max Grav 3 = 85(LC 1) 2 = 184(LC 1) 4 = 64(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 vide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 It, uplift at joint(s) 3 except at --lb) 2=103. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 21 lb down and 74 lb up at 0-10-12, and 21 lb down and 74 lb up at 0-11-1 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead * Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (pil) Vert: 1-3=54, 4-5=-20 Concentrated Loads (lb) Vert: 8=86(F=43, B=43) r„q r e..mo-.6airmlgan(sv¢y¢u(miisramnumi�efdrs:mnu:un•d.lchbwr�ddannminnn,,su�4ldm✓•snrtletaiiwods:§,,;<ra„m and mlce,nY '.. Wteloam,fkn Y$YmlhrblrJbk�dl6bLm EMpf�eQ 1rm0(6,+aril.4mugtenPuminYEpnad6ptln9nd9YB=inA ?3�IdIA,IritdhwJ NnlyntlebIDCN(tla10{1 Tn1:vp+nuapNµY�mOm4�aE1 .tamiBpmLy PE6t9tl9 tl,u6ktNu4NMYyR6mYsmd1tl60mCbOmYrBaEtlWSrWIrYi3Eeq,tYtr�Idd OlbIXe106y6ttgv4ed 114E hy�mlidlPldakY A6,inx?459b1'gnVttlr�9AaelhtbidflNd �4df1e. I lxdexoueEMKaine G9tni5 Cf reblpppntlrT'�,M. rbnbfmdYtilApd141�+orPd'L'UANCi9gr,eF 9W[ryTaby,lgp}µ'IWb11]RIdSNIOttlumdd P�APtlLL llHhtmSLn 3.fndM9A419 Wllp LW ELLq➢,h,WIn4Y"ft6vAlef glP�vm.RMW i]MYISodIr,4ffY1 []MgpbNEglldrh�i@dN.rnlo rW}(gvntKlalllYp �Iw 1 51ry3�fgb AnruAaa owm3nmmum.aolnl. oro: mnsrz019 � (e 11®1AIEl1loJinun�Anlo LTosdbl4LC le mANinoll6nlomcee,r h PR'p q P ary m,npidlnedn+v�mlEe rimebpnmuGovham Ll latlinieg AelEovrLibmlo0l,ri Job Truss Truss Type Dry Ply RENARMORNINGSIDE WRMSBM63 HJ5 Diagonal Hip Girder 2 1 A01334i 0 Job Reference o Bonet A-1 Roof I russes, POn Pierre, I-L 34945, designgaltrUss.dam 3.4 = Run: 8.210 s 11 4.2412 1.5x4C 12 18 2018 MiTek Industries, Inc. Mon Sep 17 11:33:55 2018 Page 1 wl7zgtLu-2Rs2og8yMb_F_14AEOG9kl Cbz43ACz000KIFk2y.lY0 3x4 = 5 Dead Load Der.=1/161n LOADING(psf) SPACING- 2-M CSI. DEFL. in floc) Udefl Lld PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.41 Ve t(LL) -0.06 6-9 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.44 Vert(CT) -0.13 6-9 >637 240 BCLL 0.0 Rep Stress Incr NO WB 0.07 Horz(CT) 0.00 6 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 29 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purins. BOTCHORD Rigid ceiling directly applied or 10-M oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabil'¢er Installation uide. REACTIONS. (lb/size) 4 = 46/1vtechanical 2 = 378/0-10-15 (min. 0-1-8) 6 = 205/1y'lechanical Max Horz 2 = 141(LC 4) Max Uplift 4 = -63(LC 26) 2 = -151(LC 4) 6 = -112(LC 5) Max Grav 4 = 61 (LC 19) 2 = 378(LC 1) 6 = 205(LC 1) FORCES. (to) Max. Comp./Max. Ten. - Al forces 250 (lb) or less except when shown. TOPCHORD 2-10=-289/62, 3-10=-277/88 BOT CHORD 2-11 =1 32/261, 11-12=-1321261, 6-12=132/261 WEBS 3-6=-298/151 NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf, h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed; end vertical left exposed; porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss is not designed to support a ceiling and is not intended for use where aesthetics are a consideration. 3) This truss has been designed for a 10.0 psf bottom chord live load-nonconcument with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-" wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb) 2=151, 6=112. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 77 to down and 61 lb up at 1-4-9, 77 to down and 61 It, up at 1-4-9, and 32 lb down and 41 lb up at 4-2-8, and 32 lb down and 41 lb up at 4-2-8 on top chord, and 63lb down and 35 lb up at 1-4-9, 63 lb down and 35 lb up at 1-4-9, and 14 lb down and 40 lb up at 4-2-8, and 14 lb down and 40 lb up at 4-2-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plo Vert: 1-4=-54, 5-7=-20 Concentrated Loads (Ib) Vert; 12=-9(F=-4, B=-4) ra=1 imn.eghma.a utxrnsla(muryruwmiarmanaiamnxrf®m7wcmrcelmear.drti7r�ae,�.n.wlaam,phmlm7•amAr r1 um¢aawnn�rM.: mti,�m.mmd.mme,..y f wmooxrb+4smwmmnooa,m. meual®�up[gwyi spmltte�rimmmmmoanaamaapmnmraamim;aa.p av4mrmmwpaaw, t agaumamoaq mono mAamaaa*mlexammn<vnmP .mmaowia,veevem dmnytwssmmFwn4 aaa�rammaraomt.e:meaaroewoenaa:.a>weamocm,amdn�AAdsgmbaou rycaa+ummammmu namtnMa�lgagmm wm�;.e�aa4mamr!aln,r ww•xo,:a wtinnreumem amajpegmmlravW.vvamwrarrmdmrmtdyanuama�ayrmy�nsrnrn6Pmm;�piuehmmix.mre.oaa6mau�eiwimarm, pa�ax smramiaWuw m, u mr�mAmae;m� ""s""tlee1tl� rde.delGEdretsm btli0elhdPaaki9N.Relwm4 awmarra mvylaa, P fi? r. Pe,u.ns.we � maA� m wvlma•, t„sm.dAmaxmwA4 A¢t4amimmeame4waml. om.: mnrmrs (vppigEl �101AA I Ivdinnes�Avlly 11 ivrtdv N, P.! lepmdvmvvvtll'udvtioegr,Ivmyhlm,rsfiuLbikd.nbvmlN adnvvpeionmvhamA IBaollinuS-AvAivaji.7evtolA,PE HJ7 IDiagonal Hip Girder I1 I 1 I A0133471 2x4 = 1.5x4 11 314 =' 6-0-13 3-9-3 LOADING(psf) SPACING- 2-0-0 CSL DEFL, in (loc) I/dell L/d PLATES GRIP TCLL 20.0 Plate Grip. DOL 1.25 TC 0.34 Vert(LL) 0.04 7-10 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.37 Vert(CT) -0.07 7-10 >999 240 BCLL 0.0 Rep Stress lncr NO WB 0.25 Horz(CT) 0.01 6 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 42 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 obbracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 4 = 77/Mechanical 2 = 51610-10-15 (min.0-1-8) 6 = 377/Mechanical Max Horz 2 = 182(LC 4) Max Uplift 4 = -63(LC 4) 2 _ -190(LC 4) 6 = -129(LC 8) Max Grav 4 = 77(LC 19) 2 = 516(LC 1) 6 = 377(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-11 =-647/176,11-12=-607/199, 3-12=-561/195 BOTCHORD 2-14=259/572,14-15=-259/572, 7-15=259/572, 7-16=2591572, 6-16=-259/572 WEBS 3-6=-667/303, 3-7=-1/281 NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and dght exposed ; end vertical left exposed; Lumber DOL=1.60 plate gdp DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the m bottochord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except at —lb) 2=190, 6=129. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 77 lb down and 61 lb up at 1-4-9, 77 lb down and 61 lb up at 14-9, 32 lb down and 41 lb up at 4-2-8, 32 lb down and 41 lb up at 4-2-8, and 56 lb down and 87 lb up at 7-0-7, and 56 lb down and 87 lb up at 7-0-7 on top chord, and 24 lb down and 35lb up at 1-4-9, 24 Ib down and 35 lb up at 14-9, 131b down and 40lb up at 4-2-8, 13 lb down and 40 lb up at 4-2-8, and 381b down at 7-0-7, and 38 lb down at 7-0-7 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 141=54, 5-8=-20 Concentrated Loads (lb) Vert: 13=-72(F=36, 8=-36) 15=9(F=41, B=4) 16=61(F=-30, B=-30) r Vrlm6+nrlrrntibYil]Of ll®rp>�ytRii!1Qi6df�NOntBPprfl9njINC1'➢ilrrhnreryhgryuCmtlrtd.nen LeoOrpbmglllUd YlLuILL blLfllda�m4,dl�tu E4vitu.trr SadnYR9,m'j ILlekmm�Mlb+YtlhmdYblpp�k MLA LmtOnPtrWolY•kaysrfgz4YWnm11E0nGY�n�y�mptlpdnVodurysp7gegeMAtllh•Yktptld¢jel 6LyulmY100 }N IIH A6pw,ysae,419Y�nG�md� tlwtB6s�PEuam ' tlm,tlk{teuYn!YYyhYrt¢u6rrdYp YA+eiieExRtlePeYYY9peym,mb,madYlGYItlMMhe^in4i64L N4A1NiY WdaG1 EY1mttLiYltl4imR tlCP[m a�hd9d&AYrtpaNLld tti+ab xwaePNneae,e ua,sth '�(�tl'+ir�b'�nirann.l9nirfXMaYfiBVIhP�rolTd�atlYfrl=mfW�+P�1btltMa„l�1d�01N¢tlfln m,Jvmlte FRmtlA'rim.11,ImM1¢tYnWnNsnilNtitYLHWrIpc.190uWr�mellmtYSN®'4sM ttP'ww�R�Lsw V2aiv/f dlf�a�dW�dd•Ahrarhdluwt+tlrti Mimrd,gEgvm6/Nbb'dm WggminufryM6iondgkWr 4ponfcJtnvemiMdC1141. ome: GBnYNte (vpp phl®9dldtl lodiressrs-Amdavyllvm6vlq Pl teprvdmivvdlhudvmoem,wvgpom,isploLbEednPo:mnr viilhvpe,mrsnovhvmbl YefUmus-AePovvr[7vmEoIII,PE Job Truss Truss Type cry Plv RENAR MORN INGSIDE WRMSBMB3 HJ7A Jack -Partial Girder 1 1 A0133472 Job Reference optional) A-1 Roof Trusses, Fort Pierce, FL 34946. design@attruss.com 12 3x4 Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 Mr-ek Industries, Inc. Mon Sep 17 11:33:57 2018 Page 1 ID:tWYXbtUGW VXBg9MPyEYwl7zgtLu-_q oCr9CuCEzDLDZLpidpSlsCugdgj2JmELpxyc IYO 4.24 12 6 1.5x4 II 2.12 12 3x4 13 (4 ' i Dead Lead Dell. =1181n 13 LOADING(psf) SPACING- 2-M Cat. DEFL. in (loc) I/deg L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.68 Vert(LL) -0.08 5-6 >999 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.76 Vert(CT) -0.17 5-6 >693 240 BCLL 0.0 Rep Stress Incr NO WB 0.70 Horz(CT) 0.02 4 We Na BCDL 10.0 Code FBC2017/TP12014 Matdx-MS Weight: 39 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 4-10-15 oc pudins. BOT CHORD Rigid ceiling directly applied or 8-1-8 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 413/0-9-13 (min. 0-1-8) 3 = 162IMechanical 4 = 309/Mechanical Max Horz 1 = 140(LC 4) Max Uplift 1 = -75(LC 4) 3 = -117(LC 4) 4 = -65(LC 4) Max Grav 1 = 413(LC 1) 3 = 162(LC 1) 4 = 309(LC 1) FORCES. (lb) Max. Comp./Max. Ten. -Al forces 250 (lb) or less except when shown. TOPCHORD 1-10=1385/392, 2-10=-1325/416 BOTCHORD 1-12=503/1291, 6-12=-498/1303, 6-13=514/1290, 5-13=506/1308 WEBS 2-6=0/251, 2-5=-1279/498 NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf, BCDL=5.Opsf; h=13ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed: end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 240-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Bearing. at joint(s) 1 considers panallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4 except Ot=lb) 3=117. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 16 lb down and 16 lb up at 14-9, 75 lb down and 61 lb up at 14-8, 35 lb down and 50lb up at 4-2-8, 321b down and 44 lb up at 4-2-8, and 581b down and 931b up at 7-0-7, and 57 lb down and 90 lb up at 7-0-7 on top chord, and 6lb down and 10lb up at 14-9, 21 lb down and 17 lb up at 14-8, 16 lb down and 16 lb up at 4-2-8, 19 lb down at 4-2-8, and 36 Ito down at 7-0-7, and 38 Ib down at 7-0-7 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (pit) Vert: 1-3=54, 4-7=20 Concentrated Loads (lb) Vert 2=2(B) 6=-14(F=-0, 8=-11) 11=-79(F=-37, B=42) 12=-6(B) 13=-64(F=29, B=-35) meq.hmmmJ�l{m,YVQ'11[NIIIaffBryuEhamurtreset�mcuanv�'QMllurrinumffin g�kYvnrn•tl^„a,eae..m5lnnamvYv�vrl�rm+bJmrGrrbait�m.vmYv..,. er,.�Qnetltl bn0, M1 WIHa•0nkuil9QMQ6148YNNQ4eLrttN9ea4m!P. SWetY3'+Y:heieelWLnyei6,vmP!Y'+tlQF•smG4b2'q 9mEWrffiQktpiQaj NR4mdYbIDOabclvNN.fily+PvapeR�9C�niA31®'1 Ju,eBOun�y, aE stno9 deiEOulmiWrcYap66mfma!hLQOMQOm'ssh6tl�YblwtliJBa(r+,YQ,aD9Ah0CIDSB Imhdlo�3o4NPm➢eGnMdhOAmmdY n66tns4h0C4lvt9in'RmffiIeadYWiilihQngw31TJ- f vnMexauu e+9MennacYsfais QNYeJ`reprtltmucitleM�EtlY6lfAtlbRmal¢iGd'ID �06'M391�1�m1�m'°�°I�1�!YeWAaiiWmstlumlhpma'PdYm lnl6Yut4�,4YYY1Mt¢1kbP4x141Y�yvi straPT�+mWIm[Mm4nvn,def RP u,Rss�iw eevtlulmrdkefbadq,gyni�rWdll.TY��Le1�e+4µ�Iggm6WiblWygngq Ivn4{Ci[poev4arLE9q ARtgk03hunm4h3bRB. om: oeni2m9 • OplrigM®1g11AllvvtTre+seg/mhvvrl.ivomalll,P.E pepivlvmvedlhadvanrgS+oYvlbie,bpiog3hdmilhpvllde vmkvpumurnvhvviAl gvdLnietgegvvll;ivmhegl,Pi LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) 1/defl L/d TCLL 20.0 Plate Grip DOL 1.25 TC OA8 Vert(LL) -0.00 8 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.04 Vert(CT) -0.00 8 >999 240 BCLL 0.0 Rep Stress lncr YES WB 0.00 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2017/rP12014 Mabix-MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-0-0 oc pudins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 175/0-M (min. 0-1-8) 5 = 13/Mechanical 3 = 33/Mechanical Max Horz 2 = 63(LC 12) Max Uplift 2 = -59(LC 12) 3 = -25(LC 12) Max Grav 2 = 175(LC 1) 5 = 31(LC 3) 3 = 33(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 3. LOAD CASE(S) Standard PLATES GRIP MT20 2441190 Weight: 9lb FT=10% rnyioas„ghmnm•nuarrtm¢(;muyciiurtuitrmmruarmrm uocr�aumrn>•=heaar�mdwm, m,tm:Mv�+ai?�;dm+r�rt.u�4rimmmabste... an:�+mmd.a�,.5 f WrrmcorkuacswammoavW�4,ume.g,hW!dW-L� . mu mm?mmr,oaP..+��mv+�.�ww7fmr s�tr<amNdm�birnvym.,mtaoet.auu r.r�Swwp�¢��mams.asmr +waunwasczare d',auheuxmrdWrtmmr�nm.emmm,ma..ri•�aysemmkn?� mmaamm.avmmuar rq,d,mmt.mu,mammodarvu emrms!��mm.maecmd�naeammwuxMu vma.e�..r�oo-.�aua,sis dm',=i?�s.r[mvm..mm.crmdmrmatdx�av,m;mnarai$as5nm�mpmlW�Gmmvumm�am�v�.rmemsmmpa+sww:ramepu ipcm<r�,mytip.mruurmrri.,.m ••s, s�aymaw. ,:e.�.r��hrmxmm.rmk�rhm�m,6d�*r.thimuarrmmkemme+�etm+aa.rnns�o,rwmomw+a mvtermeBm.�amr. av�..na.we 0 EI® ono: aen.vms ppig 78161Iloolinssn-Jmdmylao¢6e19,LL[eymdodioa AOislommem,mu�4u4ppiohiEdidp�Eande vrmevyeimisuoe6omAlBoAiiusiii AeiAnoyLTevAolO,IE Job Truss Truss Type Oy Py' WRMSBMB3 J4 Jack -Open 1 1 �RENARMORNINGSIDE A0133474 .lob Reference (optional) A-1 MOoI I ❑lsses, ron meros, FL saaaa, 0eslgn(Na11russ.com ttun: a.ziu s May la zma vnnl: a.zlu s May is 2u1a MII ex Inausmes, ma Mon sep i i il:a.f:na zula 6.00 12 2x4 = 3 4 4-0-0 LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/deft Lld PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.20 Vert(LL) 0.02 4-7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.16 Vert(CT) -0.02 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/7PI2014 Matrix -MP Weight: 15 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 4-M oc purins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. (lb/size) 3 = 87/Mechanical 2 = 23510-8-0 (min. 0-1-8) 4 = 45/Mechanical Max Hom 2 = 103(LC 12) Max Uplift 3 = -62(LC 12) 2 = -64(LC 12) Max Gmv 3 = 87(LC 1) 2 = 235(LC 1) 4 = 69(LC 3) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf, h=13ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 3) n This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift at joint(s) 3, 2. LOAD CASE(S) Standard oven lmmvrlY{mYeh ui&!113Sfo(mla)a(Ci1t11118,misamrmi0ponn Yu@•.muor Te fin, ^a^edm.ru1mtW 64 v�wdrlEbrufd,Wiu.m4xlh.m. mtiuz<rmvcamdpry ' 1n,cammnsrm9mevermtummnttL tn<,r!ro�I�+WvmlbmYvmsm nmmvemme,qm.,amr��+rfv�umro®eegra+mwamu,♦,Imshswuamnv0.mmmL br�wmwmauswmz.Awaa1 Axr eowwreaxam edeunmlruk RItlYGA01vRaMmftlrOm4rOmi.mStl9ciYmNMa➢Ee9C2lC,CNAmOCrB'vlEem9MGfnlrml0.l TnGm. NJmID4o1 trll,a@rrnxtibfi9lz(+iuEaYG'Mmihrpil3hhmA0lh( enmxmx Erae,ee•V G9i6,6 mraml�Zmrvmv+..a.r�rAmmmmae��N^m em'r!�na4�'�aFv""�nt�1W�Nudauo•Nv�m oats: a,++mtiro" marc:lautieWuu�wcim: mlaurma.n,.tii us,sw�e eiw. eannelrrudkemem H 4' tll r2rtLl41n m1'JIm13 gl Vam[a mR a: is 'rm� revn,f..nsasla • T 9a !vmgh ter+ WwaSue, 'Aipr1arlundme[avw0 Nuu{W, igLL3mJrmremd8adblml. Mz vensrzme 0ppiphl®1016k7lovlianm./.ellvetl.romOV IIt/L fepndomaeo1166Aommeel.iemykim,uPwEiEdepnldvN@a vnrcseye�, mhem A.I BcetLnRv AomovyGTomE>OI,Pi Job Truss Truss Type ON Ply MORNINGSIDE IWRMSBMB3 J4A Jack -Open 2 1 �RENAR A0133475 Job Reference (optional) -i hour i ruses, rori Heim, FL 34946. ausignLa muss.com Kun: 82lu s May 18 2018 Pont 8.210 s May 18 2018 MRek Industries, Inc. Mon Sep 17 l l:33:58 2018 Pagel ID:tV YXbtUGWVXBggMPyEYwl7zgtLu-SOYBOBAgfWMgrVolvXpsMgg9kIAJPLHS41rvLNyUYN 1 31:0 1 40 30 2x4 = LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (roc) Udell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) 0.01 4-7 >999 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.09 Vert(CT) -0.01 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 13 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 3-3-0 oc purins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 67/Mechanical 2 = 210/0-M (min. 0-1-8) 4 = 34/Mechanical Max Horz 2 = 88(LC 12) Max Uplift 3 = 48(LC 12) 2 = -62(LC 12) Max Grav 3 = 67(LC 1) 2 = 210(LC 1) 4 = 55(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 pal bottom chord live load nonconcument with any other live loads. 3) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) 3, 2. LOAD CASE(S) Standard Was finaa. fla j6p3:[marl^hNscumrun(4Td1u11n1a:urrlrilvrhmwrzvm^mum.mnmmnrmctwl mm4tar>•u3Aii9dzmo,nthe.. 61vr6;. and m1W.ul� I lrtdmmalmnil9m rmmlEBPkNd4rlmrMp(ymi4.Srmvlhev^imu9 mIR]Wve[�m.4�amyimmdgsreyrzn'meagmm4�grdasj mrz Lyadremmoaq m:tnS mrhpryNv. rsgvmmf veilmq- .im,meowuapff azsos mm,tis4,uleclkYi6m,nrsb.eldamKbOmlrb�ErIWYmNYeirv4rtlamiErlm04mRmESY1FA(gd.¢30FL mglmtldmlWduNJ 6mlmclal'i9lahlvT S09.vrv�Mnid�Fa 9arlkl 1. usS 6l w�oB &�wmeeMaustms mmmq&iQnmfrmmv. Nms4ulNmmloomapm�impvlveNmm�WrymsegromlrtPrmolelgL%mNam�duevampm.p�vitniati:tr Imaq.,aeeuemtmmu.r tmsongtitanmir, urmv�iu,em rammrdedlPraavT45vbilb{1IdIrCJhdrtL rRlPurW\fgomhln6rd R%um.R9r9r6 � YyMtm,vbmiry*m6jmadRbl2A Apmt3iaivvvemlddmlM1l. � Ona: mNS'Ata Lvlynlb®9AIAA l lvdiieaes�/.mlvvyl.ivvivigl.F: lepmdmivevllh'ulvae¢m,mm7kiq.iswvWbkErAumme vrirtevpeieiimovhvm A -I l.virinu;�Am6evjLivmle W,ri Job Truss Truss Type Qty Ply A013347G WRMSBMB3 J5 Jack -Open 3 1 �RENARMORNINGSIDE Job Reference (optional) A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print 8.210 s May 18 2018 MiTek Industries, Inc. Mon Sep 1711:33:59 2018 Page 1 ID:tW YXbtUGW VXBg9MPyEYwl7zgtLu-wC6ZdXBSQpVhSfNyTEK5u W FciR28oXW yjStpy,.IVM 4-0 5-0-0 1-4-0 6-0-0 R U4= 6.00 12 5-0-0 LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/deg L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.49 Vert(L-) 0.11 4-7 >554 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.44 Vert(CT) 0.09 4-7 >650 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Hou(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017rrP12014 Matrix -MP Weight: 18 lb FT =10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 5-M oc puriins. BOTCHORD' Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 1131Mechanical 2 = 269/0-8-0 (min. 0-1-8) 4 = 59/Mechanical Max Horz 2 = 123(LC 12) Max Uplift 3 = -81(LC 12) 2 = -98(LC 9) 4 = -48(LC 9) Max Grav 3 = 113(LC 1) 2 = 269(LC 1) 4 = 88(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; end vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) 3, 2, 4. LOAD CASE(S) Standard 6nJq 11s, mwgymnrh'NIBM 11ffi6(01R160dfFiaYSrrNtn106 �iGN('tbRIN10iJVAaI"LruYVYINuylms,Msdml rvLmOng8m6111f4��bl�rl.IubRrtplam9MNmu 01nv6a�m MdvhR9.mlj breY�enlmslflbmlb b3D% h K4 hkI 1e919! OI40 el dm4ith IvsgitlBgkbmlmYq[bAm,b0vet5rAaddq.6ebWbbpe"s}+tibn0GdM6C650 vibadlud[gMVMR]liegpmitlbippalu.rell hbpdNWPe lry@Ivblav4 Nn1PF1. bInPw.Arv,W Qbb+iu,lwtvai6j- rms6ffgtF�fsgrfuOAfuviNltl,pd0bb6gsbi%C Jem BBun�v PE62Bo9 w^'^ E abqu5i6i5 ' mbdarngadrmnc Nnbu:Whla�bl� lilPB9ry�dPoltatilW:��B1A°n6�n(RM1.r,NiLl��Wd90N5tlnmlYt®d�IaY.1M1lMtltb�M66i9alN�EMLWrniP.)fl'1rLL9.4'b?m1INY0t�Ye4R RPb,m.R96G6 PSuelvl3odM6f6+dryMgo9M6rhervWl*di,1,TelnuGg6gYivhlNb6AYpi��aNfSSyC®igvtrlglday {RppLkdFun613tlro1n1. Ose: p9nYN10 • lepn gM.®1016AIl6dinsies�JmdeslLlamhelO,Pi tepMv�iosdnodomsum,iemyivB,ayiah3delvi@omthe vrme6peieusmrhemA llaofkllsir AmAv6rC18mEeN,Pi Job Truss Truss Type city Ply MORNINGSIDE WRMSBMB3 J7 Jack -Open g 1 �RENAR A0133477 Job Reference (optional) A-1 moot Trusses, Fort Pierce, FL 3494b, design(malvuss.com Run: 8.210 s May 18 2018 Print 8.210 s May 18 2018 MITek Industries, Inc. Man Sep 1711:33:59 2018 ' ID:tWYXbtUGWVXBg9MPyEYwl7zgtLu-wC6ZdXBSOpVhSfNyTEK5utN9_INt8oXWyj; 7-0-0 , 3x4 = 7-0-0 Dead Load Defi. =118 in LOADING(psf) SPACING- 2-M CS1. DEFL. in (too) I/deb L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.85 Vert(LL) 0.17 4-7 >478 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.65 Vert(CT) -0.22 4-7 >386 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.01 3 me n/a BCDL 10.0 Code FBC2017TFP12014 Matrix -MP Weight: 24 lb FT=10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-2-0 oc pudins. BOTCHORD Rigid ceiling directly applied or 10-M oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 164/Mechanicel 2 = 340/0-8-0 (min. 0-1-8) 4 = 85/Mechanical Max Horz 2 = 164(LC 12) Max Uplift 3 = -117(LC 12) 2 = -79(LC 12) Max Gmv 3 = 164(LC 1) 2 = 340(LC 1) 4 = 126(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vuit=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. It Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2 except Qt=lb) 3=117. LOAD CASE(S) Standard trW lm6+ghvMb'41r10fi�(4llg)6n31tIV9StlNZP�%afl'WI(6,1a1L11C1'.EYiarbn 4virkYpyau9mnirtirM blminpF�llf4;dblGayLL-a411Ldeve4Mkeem bivsaGcMalleReln.r} &@tmmn4 tldtrmlbbn9vY YL� Lmrapigscp ymNyh�v;huJ gla�vmnrvpnatlbptl fnfqa a3�'9mLty(trblryftlb�y'ihrvtgtldubID4eLjaly VN IYLrcg,nw,mm,MgWmvynetl4T Jaru�90w�PEaxma dmtl6:Yj-.uk NY,1♦M1brtiy:aMALbAu460tvi4r4Ltl F.1Yb1, YA4v� hm0/b Y4Niel0eM%YnWevIIIFL Tn4TMIh09dPleAev Cl�Iw[^9figtffi4.aLtvt+ffiaefbva!>6066i^PulWtl W31615 trr4sy e14ivmc LSetlrdty bIIOolbiw'vlofPtlelvv"FOi4tYrreW$ICnllhtwlxNktr!+IFbItlfYJmltive9itepvNptlm lM1rkBe[4mImb3Ltif4b[ieM bilP?1 rEnT teS�ellmsYm¢tl�v,eGn I I�aSlSwtla B�i.anemu,e ofuMVldvdkeUltlgMywti�RlgMtllplee4,9iei.9Him hYp6ym(tC1blAYy ingn innSry'itFq] Rmt41b{fOW%v3trmreulisl➢11V1. Deco: OanSrzma D.:ay. Ulr • fopp@TI®1011Ai Wdlnure Mli.ylt=I11 P.0 lepmdod�oodlhbiomoen,mmllam�ispaG3Aedr MomWevntteepeimisvwfi mknaATiieui AnEovyi.TovReI11,PL Job Truss Truss Type Oty Ply RENAR MORN INGSIDE A0133474 WRMSBMB3 J7B Jack -Open 4 1 Job Reference (optional) I A-1 Roof Trusses, Fort Pierce, FL 34946, design@aibuss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Mon Sep 1711:34:00 2018 Page 1 ^ ^ ID:tWYxbtUGWVXBg9MPyEYwl7zgtLu-OOgxrtC4B7dY4oy8lysKR5wJP5hJtFnIYcS0OFeYL Dead Load Deft. =1/8 in 6.00 72 n 1 e e e 3.00 72 4 3x4 LOADING(psf) SPACING- 2-" Cat. DEFL. in (loc) I/deb Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.94 Vert(LL) 0.21 3-6 >400 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.76 Vert(CT) -0.24 3-6 >353 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.03 2 n/a nla BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 23 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied. BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 257/0-8-0 (min. 0-1-8) 2 = 168/Mechanical 3 = 88/Mechanical Max Horz 1 = 141(LC 12) Max Uplift 1 = -38(LC 12) 2 = -122(LC 12) Max Grav 1 = 257(LC 1) 2 = 168(LC 1) 3 = 127(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - Al forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. ' S) Bearing at joinl(s)1 considers parallel to grain value using ANSUTPI 1 angle to grain formula. Building designer should verify rapacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except Qt=lb) 2=122. LOAD CASE(S) Standard Yvenhvaa,sgrmtre m'niv0 a�IDa({pla'}8131L08t0Q11p)peSCWCtlI(111a)1O1EVBilarbnLv(ed,Y�imtivsd,deT+aMslms9nlpEmq�[4jtlblfblLich4111tlera9ylHrtu tlu ��m Mdn6eIDl,m�r P1DItv+twixu+leGmlb,blE,9l M,di 6eLvemp�!!P •IW%.6"�vlhuJovlIBOSPve'sem1vdtrTJatlsleTnv4a9>aslblSfthYsptlbwJtimsbAMnb144+$ebtlN 161si'�.nuxWbld9a!lvOdf Je�eabm�PE5tx9 tl,16'uimtbeqbXiqvbmraCi.gd4ONLbO+aflitautl9lYOfiuXviEnlpcvbimMd61R.L.L'tribfidklipnlevlWl Th@PaA/600N Wi rtblmxH9iFattSimV,.M9veIMYGq M.Ylevgadl�6 Kloe Xarse ugMvW G91815 ' PWsr 4v rxpvgaa �bMphvpngrtliea.IDeebmWvpitOtlbjmalodW'Ji+Jhltlbl�R'��eReuluuR37NwLlflIDtl&ltltd�bRwPdmfiilEtibmnvd•'+Ivbirtii(4Lisi s mirav MtfiMv,ef3 bsv ewm aw. aam.. ttvwe % �rnh Ww bvprglur" iMs¢a lsslyf�v LnbKd9rbrR4 N��l�umm41WD1lVL- � i3vldaWad e(sEedmdeDeY a e]iH:1h1u 610141ldv Om¢lBei520ty � (eprr pbf.®,101lAIWdinsseniciEvvRl.lvulem,P.0 RepmleAvvllNddvvimeer,wvvylv�m,bpivhiyaedl�nverMa vrivapeimuriovhv®A lAudimut 1vtAvvri.7a�al0,Pi Job Truss Truss Type 4ry Pry RENARMORNINGSIDE WRMSBMB3 VO4 Valley 1 1 A0133479 . , �_ „____ �_, �.____ �, -,�,,, ,__,_�_-._ Job Reference (optional) 6.00 12 2 3x4 = 2x4 G 2x4 1 2018 MiTek Industries, Inc. Mon Sep 1711:34:00 2018 Page 1 4 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (Joe) Weft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.06 Vert(LL) n/a - n/a 999 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.09 Vert(CT) n/a - n1a 999 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix-P Weight: 10 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP Nc.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 4-0-0 oc puriins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installa0on quide. REACTIONS. (lb/size) 1 = 101/3-11-0 (min.0-1.8) 3 = 10113-11-0 (min.0-1-8) Max Horz 1 = -11(LC 8) Max Uplift 1 = -24(LC 12) 3 = -24(LC 13) Max Grav 1 = 101(LC 1) 3 = 101(LC 1) FORCES. (lb) Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)' This truss has been designed. for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. LOAD CASE(S) Standard J fep}ifpgt.901641INlmues�/edavrr.iomha O,P.L JYe1BpmIry PE6}HIi Whu Ww eginMiq G9t818 Y51 SYIYv&r4 FL Fiun.RedMB pab: CBY S20r8 Job Truss Truss Type Oty Ply WRMSBMB3 V08 Valley 1 1 �RENARMORNINGSIDE A0133480 Job Reference (optional) A-1 ROOT I MSaaS, tort VIerCO3 rL a4 , aesignLmalLNss.com ltun: o.LIU s May Ia ZUIa rnm: a.ZIU a May la Lela MI IeK Inausmes, Ine. Mon eep i / I1:6 :U1 LUIa O 2x4 G 6.00 12 3x4 = 2 2X41 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.28 Vert(LL) n/a - n/a 999 TCDL 7.0 Lumber DOL 1.25 SC 0.60 Vert(CT) n/a - We 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC20171TP12014 Matrix-P LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-M oc bracing. MiTek recommends that Stabilizers and require" cross bracing be installed during truss erection, in accordance with Stabilizer Installation quids. REACTIONS. (lb/size) 1 = 249/7-11-0 (min.0-1-8) 3 = 24977-11-0 (min.0-1-8) Max Horz 1 = -28(LC 8) Max Uplift 1 = -59(LC 12) 3 = -59(LC 13) Max Grav 1 = 249(LC 1) 3 = 249(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 1-2=-236/276, 2-3=-236/276 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuousbottom chord bearing. 4) This truss has been designed for a 10.0psf bottom chord live load nonconcurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. LOAD CASE(S) Standard i PLATES GRIP MT20 244/190 Weight: 23 lb FT=10% bdf. {. aaeleowzrre ware Miae Hwm 6gaw,4q G 91819 K flLn-@ Wm..1. DA: ..1. Job Truss TuasType Oty Ply WRMSBMB3 V12 Valley 1 1 �RENARMORNINGSIDE A0133481 Job Reference (optional) 1-1 Roo, Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Mon Sep 17 11:34:012018 Page 1 ID:tW YXbtUGW VXBg9MPyEYwl7zgtLu-sbEJ2COjyRiOiyXKafNZ_ISd3V83chhumGCZyiyclYK 44 = I 3x4 4 " 3z4 C 1.5x4 II 0-0-8 11-11-8 - -- LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.37 Vert(LL) n/a - n/a 999 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.28 Vert(CT) n/a - n/a 999 BCLL 0.0 ' Rep Stress Incr YES WS 0.09 Horz(CT) 0.00 3 We rda BCDL 10.0 Code FBC20171TP12014 Matrix-S Weight: 39 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 OTHERS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied orb-0-0oc purins. BOTCHORD Rigid ceiling directly applied or 10-" oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 180111-11-0 (min. 0-1-8) 3 = 180/11-11-0 (min. 0-1-8) 4 = 434/11-11-0 (min.0-1-8) Max Hom 1 = -44(LC 8) Max Uplift 1 = -60(LC 12) 3 = -67(LC 13) 4 = -70(LC 12) Max Grav 1 = 183(LC 23) 3 = 183(LC 24) 4 = 434(LC 1) FORCES. (lb) Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. WEBS 2-4=-279/292 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3,4. LOAD CASE(S) Standard {vppVu010I1k1 Wdrmcus�RievgrlocAvpi,pE .rum n uwmvee WIrY{hum FryMx,lry C 91.5 .asis --ma. ft P'+ru.R41Ne ed�: 049 SR018 JANUARY 17, 2017 TYPICAL HIP / KING JACK CONNECTION I STDTL01 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 CORNERSET GENERAL SPECIFICATIONS MAX LOAD: 55 psf Roof Load, 175 mph, ASCE / - 1 V, LAp- U, %! UN LlJ VO-IVIGQI-1-1-\IJFJ l-1-1 GIyNL and Exposure D up to 30' Mean Roof Height. Attach End Jack's w/ (4) 16d Toe Nails @ TC & (3) 16d Toe Nails @ BC 0 Attach King Jack w/ (3) 16d Toe ,Nails @ TC & 24" Strap w/ (6) 10d x 1.5" ea. end @ BC ach Corner Jack's (2) 16d Toe Nails TC & BC (Typ) Attach Comer Jack's w/ (2) 16d Toe Nails @ TC & BC (Typ) FEBRUARY 17, 2017 1 ALTERNATE GABLE END BRACING DETAIL I STDTL03 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORD 1'-3'MAX. DIAG. BRACE AT 1/3 POINTS IF NEEDED IT IS THE RESPONSIBILITY OF THE BLDG. DESIGNER OR THE PROJECT ENGINEER/ARCHITECT TO DESIGN THE CEILING DIAPHRAGM AND ITS ATTACHMENT TO THE TRUSSES TO RESIST ALL OUT OF PLANE LOADS THAT MAY RESULT FROM THE BRACING OF THE GABLE ENDS. HORIZONTAL BRACE /- 2X6 DIAGONAL BRACE SPACED 48' (SEE SECTION A -A) O.C. ATTACHED TO VERTICAL WITH TRUSSSES 0 (4) - 16d NAILS, AND ATTACHED TO r 24' O.C. BLOCKING WITH (5) - 10d COMMONS. NAIL DIAGONAL BRACE TO PURLIN WITH TWO 16d NAILS. 2X4 PURLIN FASTENED TO FOUR TRUSSES WITH (2) - 16d NAILS EACH. FASTEN PURLIN TO BLOCKING W/ (2) - 16d NAILS (MIN.). PROVIDE 2X4 BLOCKING BETWEEN THE TRUSSES SUPPORTING THE \ BRACE AND THE TWO TRUSSES ON \VN(5) EITHER SIDE AS NOTED. TOENAIL \BLOCKING TO TRUSSES WITH (2) - \10d NAILS AT EACH ENO. ATTACH DIAGONAL BRACE TO BLOCKING WITH - 10d COMMON WIRE NAILS. ENO WALL CEILING SHEATHING BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED: METHOD 1: ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE OF THE STRUCTURAL GABLE AND FASTEN PER THE FOLLOWING NAIL SCHEDULE. METHOD 2: ATTACH 2X_ SCABS TO THE FACE OF EACH VERTICAL MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SCAB ALONG SIZE, GRADE, AND SPECIES AS THE TRUSS VERTICALS. NAILING SCHEDULE: VERTICAL - FOR WIND SPEEDS 120 MPH (ASCE 7-98, 02, 05), 150 MPH (ASCE 7-10) OR LESS, NAIL ALL MEMBERS WITH ONE ROW OF Uld (131' X 3') NAILS SPACED 6' O.C. - FOR WINO .SPEEDS GREATER 120 MPH (ASCE 7-98, 02, 05), 15D MPH (ASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF 10d (131'X3') NAILS SPACED G' O.C. (2X4 STUDS MINIMUM). MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. ALI BRACING METHODS SHOWN ON PAGE 1 ARE VALID AND ARE TO BE FASTENED TO THE SCABS OR VERTICAL STUDS OF THE STANDARD GABLE TRUSS ON THE INTERIOR SIDE OF THE STRUCTURE. aan / AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING / MUST BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS. THE BRACING SHOWN IN THIS DETAIL IS FOR VERTICAL/STUDS ONLY. NOTE: THIS DETAIL IS TO BE USED ONLY FOR STRUCTURAL GABLES WITH INLAYED STUDS. TRUSSES WITHOUT INLAYED STUDS ARE NOT ADDRESSED HERE. STANDARD GABLE TRUSS STANDARD PIGGYBACK TRUSS JULY 17, 2017 1,.. 1 STDTL04 THIS DETAIL IS APPLICABLE FOR THE FOLLOWING WIND CONDITIONS: ASCE 7-98, ASCE 7-02, ASCE 7-05, ASCE 7-10 WIND STANDARDS UNDER ALL ENCLOSURE AND EXPOSURE CONDITIONS AS LONG AS NO UPLIFT EXCEEDS 377 LBS. REFER TO ACTUAL PIGGYBACK TRUSS DESIGN NOTE: THIS DETAIL IS VALID FOR ONE PLY TRUSSES SPACED 24.O.C. OR LESS. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 PIGGYBACK TRUSS REFER TO ACTUAL TRUSS DESIGN DRAWING FOR ADDITIONAL PIGGYBACK TRUSS INFORMATION. SPACE PURLINS ACCORDING TO THE MAXIMUM SPACING ON THE TOP CHORD OF THE BASE TRUSS (SPACING NOT TO EXCEED 24' 0.0 A PURLIN TO BE LOCATED AT EACH BASE TRUSS JOINT. ATTACH PIGGYBACK TRUSS TO THE BASE TRUSS WITH 2' X 8' TEE -LOCK MULTI -USE CONNECTION PLATES SPACED 48'O.C. PLATES SHALL BE PRESSED INTO THE PIGGYBACK TRUSS AT 48' O.C. STAGGERED FROM EACH FACE AND NAILED TO THE BASE TRUSS WITH FOUR (4) 6d (1.5' X 0.099') NAILS IN EACH PLATE TO ACHIEVE A MAXIMUM UPLIFT CAPACITY OF 377 LBS. AT EACH 2' X 8' TEE -LOCK MULTI -USE CONNECTION PLATE. (MINIMUM OF 2 PLATES) ATTACH EACH PURLIN TO THE TOP CHORD OF THE BASE TRUSS. (PURLINS AND CONNECTION BY OTHERS) BASE TRUSS REFER TO ACTUAL TRUSS DESIGN DRAWING FOR ADDITIONAL BASE TRUSS INFORMATION. JULY 17, 2017 1 TRUSSED VALLEY SET DETAIL - SHEATHED I STDTL05 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 VALLEYTRUSS (TYPICAL) SECURE VALLEY TRUSS W/ ONE ROW OF 10d NAILS 6° O.C. GABLE END, COMMON TRUSS, OR GIRDER TRUSS DETAIL A P 12 SEE DETAIL'A° - BELOW (TVP.) . GENERAL SPECIFICATIONS: 1. NAIL SIZE=3'X 0.131'=10d 2. WOOD SCREW =4.5° WS45 USP OR EQUIVALENT. 3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES. 4. INSTALL VALLEY TRUSSES (24- O.C. MAXIMUM) AND SECURE TO BASE TRUSSES AS PER DETAIL"A". 5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIDUAL DESIGN DRAWINGS. 6. NAILING DONE PER NDS-01. 7. VALLEY STUD SPACING NOT TO EXCEED 48' O.C. BASE TRUSSES VALLEY TRUSS (TYPICAL) ATTACH 2X4 CONTINUOUS #2 SYPTO THE ROOF W/TWO USP WS45 (1/4° X4.5°) WOOD SCREWS INTO EACH BASE TRUSS. TRUSS CRITERIA: GABLE END, COMMON TRUSS, OR GIRDER TRUSS WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12 CATERGORY II BUILDING EXPOSURE WIND DURATION OF LOAD INCREASE: 1.60 MAX TOP CHORD TOTAL LOAD =50 PSF MAX SPACING = 24° O.C. (BASE AND VALLEY) MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. FEBRUARY 5, 2018 I TRUSSED VALLEY SET DETAIL I STDTL06 GENERAL SPECIFICATIONS: 1. NAIL SIZE=3'X0.131'=10d 2. WOOD SCREW =3- WS3 USP OR EQUIVALENT. 3. INSTALL VALLEY TRUSSES (24.O.C. MAXIMUM) AND SECURE PER DETAIL �. 4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN �i DRAWINGS. 5. BASE TRUSS SHALL BE DESIGNED WITH A PURUN SPACING EQUIVALENT TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING. A-1 ROOF TRUSSES 6. NAILING DONE PER NDS-01. 4451 ST. LUCIE BLVD. GABLE END, COMMON 7. VALLEY STUD SPACING NOT TO EXCEED 48' O.C. FORT PIERCE, FL 34946� TRUSS, OR GIRDER 7 772-409-1010 TRUSS 1 VALLEYTRUSS y i II II I VASE TRUSSES (TYPICAL) II ' 11 SECURE W/0 DETAIL A (NO SHEATHING) N.T.S. GABLE END, COMMON TRUSS, OR GIRDER P r VALLEYTRUSS TRUSS (TYPICAL) SEE DETAIL'A' BELOW (TYP.) WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05:146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT =30 FEET ROOF PITCH =MINIMUM 3112 MAXIMUM 6/12 CATERGORY II BUILDING EXPOSURE WIND DURATION OF LOAD INCREASE: 1.60 ATTACH 2X4 CONTINUOUS#2 MAX TOP CHORD TOTAL LOAD =50 PSF SYP TO THE ROOF W/TWO USP MAX SPACING 24'O.C.(BASE AND VALLEY) WS3(1/4-X3-)WOOD SCREWS MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. INTO EACH BASE TRUSS. I JULY 17, 2017 ""� V" `"" "" I STDTL07 (HIGH WIND VELOCITYI III A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 ATTAC WIND DESIGN PER ASCE 7-98, ASCE 74 WIND DESIGN PERASCE 7-10: 170 MPF MAX MEAN ROOF HEIGHT = 30 FEET CATERGORY II BUILDING EXPOSURE B OR C WIND DURATION OF LOAD INCREASE: 1 MAX TOP CHORD TOTAL LOAD = 50 PSF MAX SPACING = 24' O.C. (BASE AND VA SUPPORTING TRUSSES DIRECTLY UNC_.....___.....,---- DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2' -10' ON AFFECTED TOP CHORDS. NOTES: 1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEYTRUSSES. 2. THIS DETAIL IS NOT APPLICABLE FOR SPF-S SPECIES LUMBER. NON -BEVELED BOTTOM CHORD FOR BEVELED BOTTOM CHORD, CLIP MAY BE APPLIED TO EITHER FACE. CLIP MAY BE APPLIED TO THIS FACE UP TO A MAXIMUM 6112 PITCH NON -BEVELED BOTTOM CHORD CLIP MUST BE APPLIED TO THIS FACE WHEN PITCH EXCEEDS 6112 (MAXIMUM 12/12 PITCH) ono FEBRUARY 17, 2017 STANDARD GABLE END DETAIL STDTL08 VERTICALf 2X6 SP OR SPF � STUD#2 DIAGONAL �� TYPICAL 2X4 L-BRACE BRACE �! NAILED TO 2X4 VERTICALS V/10d NAILS, S' O.C. (4) - 16d VERTICAL --STU NAILS (2)-IDd-NAILS_INTO SP NAILS SPACED S O.C. VE SP OR 2X62X6 SECTION B-B 2%4 SP ORA-1 SPF #2 ROOF TRUSSES SPF #2446t L HORIZONTAL si. LUCIE BLvo. NAILED TO FORT PIERCE, FL 34946 TRUSS GEOMETRY AND CONDITIONS SHOWN ARE FOR ILLUSTRATION ONLY. 772-009-1010RTICALS SECTION A -A V/(4) - 10d NAILS r DIAGONAL BRACE 4' - 0' D.C. MAX. SEE INDIVIDUAL ENGINEERING DRAWINGS FOR TRUSS DESIGN CRITERIA. 12 PROVIDE 2X4 BLOCKING BETWEEN Q VARIES TO COMMON TRUSS THE FIRST TWO TRUSSES AS NOTED. TOENA* TO WITH (2) - 10dLOCKING NAILS AT EACH TRUSSES END. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - IOd NAILS (4) Eld NAILS MINIMUM -\ ROOF B* 3X4= PLYWO D5T0 AT IBLOCK I r SHEATHING Vov * DIAGONAL BRACING k* L - BRACING REFER / REFER TO SECTION A -A TO SECTION B-B 24' MAX. / 1OT.MINIMUM GRADE OF #2 MATERIAL IN THE TOP AND BOTTOM CHDROS. / (2),- 10d 2. CONNECTION BETWEEN BOTTOM CHORD OF GABLE END TRUSS AND WALL TO 12' MAX. NAILS BE PROVIDED BY PROJECT ENGINEER DR ARCHITECT.- 3. BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT'BLDG. -_ ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF SYSTEM. 4. 'L' BRACES SPECIFIED ARE TO BE FULL LENGTH, SPF DR SP #3 OR BETTER WITH ONE ROW OF 10d NAILS SPACED 6' O.C. TRUSSES ® 24' OL. S. DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM AT 4' - 0' O.C. S. CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2%4 AS SHOWN 2X6 DIAGONAL BRACE WITH 16d NAILS SPACED 6' O.C. HORIZONTAL BRACE TO BE LOCATED AT AC ATTACHED SPACED 4B' O.C. ATTAC THE MIOSPAN OF THE LONGEST GABLE STUD: ATTACH TO VERTICAL GABLE - TO VERTICAL WITH - STUDS WITH (3) 10d NAILS THROUGH 2X4 (REFER TO SECTION A -A) 16d NAILS, AND ATTACHED 7. GABLE STUD DEFLECTION MEETS OR E%CEEEDS L/240. TO BLOCKING WITH IS) - B. THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. DIAG. BRACE 10d NAILS. S. 00 NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE AT 1/3 POINTS TRUSSES. IF NEEDED 10. 10d AND 16d NAILS ARE 0131'%3.0' AND 0131'X3.5' COMMON WIRE NAILS HORIZONTAL BRACE RESPECTIVELY. (SEE SECTION A -A) 11. SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 05-01-12 BY SPIB/ALSC. END WALL MINIMUM STUD SIZE SPECIES AND GRADE STUD SPACING WITHOUT BRACE . 2X4 L - BRACE DIAGONAL BRACE (2) DIAGONAL BRACES AT 1/3 POINTS MAXIMUM STUD LENGTH 2X4SP#31STUD 12'0.C. 3-8-10 5-6-11 6311 11-1-13 2X4SP431STUD 16'0.C. 3-3-10 4-9-12 6-6-11 9-10-15 2X4SP#31STUD 24.0.C. 236 3-11-3 54.12 8-1-2 2X4SP#2 12'0.C. 3.1045 5-6-11 6-6-11 11.8-14 2X4SP#2 16'0.C. 3.6-11 4-9.12 6E-11 10.8-0 2X4 SP#2 24O.C. 3-14 3-11-3 6-2-9 9313 - DIAGONAL BRACES OVER 6' - 3- REQUIRE A 2X4 T-BRACE ATTACHED TO ONE EDGE. DIAGONAL BRACES OVER 12' - 6' REOUIRE 2X4 I -BRACES ATTACHED TO BOTH EDGES. FASTEN T AND I BRACES TONARROWEDGE OF DIAGONAL BRACE WITH 10d NAILS 6' O.C., WITH 3- MINIMUM END DISTANCE. BRACE MUST COVER SD'/. OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 OR SP #2. =30 FEET STUD DESIGN IS BASED INCREASE: 1.60 1 CONNECTION OF BRACI FEBRUARY17,2017 I WITH 2X BRACE ONLY I STDTL09 NOTES: T-BRACING / I -BRACING TO BE USED WHEN CONTINUOUS LATERAL BRACING IS IMPRACTICAL. T-BRACE / I -BRACE MUST COVER SOX OF WES LENGTH. THIS DETAIL NOT TO BE USED TO CONVERT T-BRACE / I -BRACE WEBS TO CONTINUOUS LATERAL BRACED WEBS. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 NAILING PATTERN T-BRACE SIZE NAIL SIZE NAIL SPACING 2X4 OR 2X6 OR 2X8 I 10d 1 6' O.C. NOTE NAIL ALONG ENORE LENGTH OF T-BRACE / I-BRACE,(ON TWO-PLY TRUSSES NAIL TO BOTH PLIES) BRACE SIZE FOR ONE -PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 2X4 T-BRACE 2X4 I -BRACE 2X6 2X6 T-BRACE 2X6 I -BRACE 2X8 2X8 T-BRACE 2X8 I -BRACE BRACE SIZE FOR TWO-PLY TRUSS SPECIFIED CONTINUOUS ROWS LATERAL BRACING OF WEB SIZE 1 2 2X3 OR 2X4 2X4 T—BRACE 2X4 I —BRACE 2X6 2X6 T—BRACE 2X6 I —BRACE 2XB 2X8 T—BRACE 2X8 I —BRACE T—BRACE / I —BRACE MUST BE SAME SPECIES AND GRADE (OR BETTER) AS WEB MEMBER. NAILS NAILS WEB NAILS WES I -BRACE T—BRACE SECTION DETAILSa��� NM'e Xviy ErytreNy CE 91615 4519futla &M. FL Fum.RY9b �IDe: ONYe%0 FEBRUARY17,2017 1 LATERAL BRACING RECOMMENDATIONS I STDTL10 TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS, 2X6 'STRONGBACK' IS RECOMMENDED, LOCATED EVERY 8 TO 10 FEET ALONG A FLOOR TRUSS. NOTE 1: 2X6 STRONGBACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY TINDER THE �- TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING ANY A-1 ROOF TRUSSES OF THE METHODS ILLUSTRATED BELOW. 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 NOTE 2: STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE 772409-1010 BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS FROM ENO TO END, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPERLY CONNECTED, BY OTHERS, AT THE ENDS. INSERT WOOD SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRONGBACK (00 NOT USE METAL FRAMING ATTACH TO VERTICAL ATTACH TO VERTICAL USE DRYWALL TYPE SCREWS) ANCHOR TO ATTACH WEB WITH (3) - 10d SCAB WITH (3) - Uld TO TOP CHORD NAILS (0.131' X 3') NAILS (0.131' X 3'). ATTACH TO VERTICAL \ WEB WITH (3) - 10d NAILS (D131' X 3') BLOCKING BEHIND THE VERTICAL WEB IS RECOMMENDED WHILE NAILING THE STRONGBACK USE METAL FRAMING ATTACH TO VERTICAL ANCHOR TO ATTACH WEB WITH (3) - 10d TO BOTTOM CHORD NAILS (0131' X 3') TRUSS 2X6 4' - STRONGBACK r (TYPICAL ATTACH 2X4 VERTICAL TO FACE OF TRUSS. FASTEN TO TOP AND BOTTOM CHORD WITH (2) - 10d NAILS (0131' X 3') IN EACH CHORD ATTACH TO VERTICAL SCAB WITH (3) - Uld NAILS (0.131' X 3') 0' WALL SPLICE) I (BY OTHERS) ATTACH TO CHORD WITH (2) N12 X 3' WOOD SCREWS (0.216' DIAJ INSERT SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRONGBACK (00 NOT USE DRYWALL TYPE SCREWS) THE STRONSBACKS SHALL BE SECURED AT THEIR ENDS TO AN ADEQUATE SUPPORT, DESIGNED BY OTHERS. IF SPLICING IS NECESSARY, USE A 4' - 0' LONG SCAB CENTERED ON THE SPLICE AND JOINED WITH (12) - 10d NAILS (0131' X 3') EQUALLY SPACED. ALTERNATE METHOD OF SPLICING: OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4' - 0' AND FASTEN WITH (12) - IOd NAILS (0131' X 3') STAGGERED AND EQUALLY SPACED (TO BE USED ONLY WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL). BLOCKING (BY OTHERS) ,v�.,aowgve sxue w,m xoo.. BigBgmre us+s�,icema, R Reme.RLB18 Om. MMSIMIB FEBRUARY17,2017 1 LATERAL TOE -NAIL DETAIL I STDTL11 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 NOTES: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45' WITH THE MEMBER AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS SHOWN). 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO SPECIES FOR MEMBERS OF DIFFERENT SPECIES. TOE -NAIL SINGLE SHEAR VALUES PER NOS 2001 (LB/NAIL) OIA SP OF HF SPF SPF-S .131 88.0 B0.6 69.9 68.4 59.7 co o .135 93.5 85.6 74.2 72.6 63.4 J .162 108.8 99.6 86.4 84.5 73.8 rj .128 74.2 67.9 58.9 57.6 50.3 z .131 75.9 69.5 60.3 59.0 51.1 J 0 .148 81.4 74.5 64.6 63.2 1 52.5 ri VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d NAILS (0162' DIA. X 35') WITH SPF SPECIES BOTTOM CHORD FOR LOAD DURATION INCREASE OF 1.15: 3 (NAILS) X 845 (LB/NAIL) X 115 (DOL) = 2915 LB MAXIMUM CAPACITY ANGLE MAY VARY FROM 30' TO 60' 45.00` ANGLE MAY VARY FROM 30' TO 60' THIS DETAIL IS ONLY APPLICABLE TO THE THREE END DETAILS SHOWN BELOW. [VIEWS ARE FOR ILLUSTRATION PURPOSES ONLY. SIDE VIEW (2X3) 2 NAILS NEAR SIDE NEAR SIDE SIDE VIEW (2X4) 3 NAILS FV7NEAR SIDE NEAR SIDE NEAR SIDE 45.00' SIDE VIEW (2X3) 2 NAILS ANGLE MAY VARY FROM 30' TO SD' NEAR SIOE NEAR SIOE NEAR SIDE NEAR SIDE 45.00° FEBRUARY 17, 20V I UPLIFT TOE -NAIL DETAIL 1 STDTL12 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 T72-4094010 THIS DETAIL SHALL BE USED FOR A CONNECTION RESISITING UPLIFT FORCES ONLY. BUILDING DESIGNER IS RESPONSIBLE FOR LOADS IN OTHER DIRECTIONS. NOTES: TOE -NAIL WITHDRAWAL VALUES PER NOS 2005 (LB/NAIL) DIA. SP OF HF SPF SPF-S Z .131 59 46-- 3 —30— -- 20— J .135 60 48 33 30 20 P7 .162 72 58 39 37 25 J 2 (, .128 54 42 28 27 19 Z Z 0 .131 55 43 29 28 19 LU .148 62 48 34 31 21 J 0 J N Q M Z .120 51 39 27 26 17 Z .128 49 38 26 25 17 0 .131 51 39 27 26 17 0 .148 57 44 31 28 20 M 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30• WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER ENO AS SHOWN. 2. THE ENO DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE BASED ON THE SPECIE WITH LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN THE CONNECTION. VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d NAILS (0162' DIA. X 35') WITH SPF SPECIES TOP PLATE FOR WINO DOL OF 133: 3 (NAILS) X 37 (LB/NAIL) X 133 (OOL FOR WIND) = 148 LB MAXIMUM ALLOVABLE UPLIFT REACTION DUE TO WIND FOR WINO DOL OF 1.60: 3 (NAILS) X 37 (LB/NAIL) X ISO (OOL FOR WINO) = 177 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WINO IF THE UPLIFT REACTION SPECIFIED ON THE TRUSS DESIGN DRAWING EXCEEDS 147 LBS (177 LES) BUILDING DESIGNER IS RESPONSIBLE TO SPECIFY A DIFFERENT CONNECTION. +++ USE (3) TOE -NAILS ON 2X4 BEARING WALL +++ USE (4) TOE -NAILS ON 2X6 BEARING WALL NEAR SIDE FAR S', 3E TOP PLATE OF WALL VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY SIDE VIEW END VIEW FEBRUARY 5, 2016 TYP 2x2 NAILER ATTACHMENT I STDTL13 a A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 "1.5X4 2x2 NAILER ATTACHMENT GENERAL SPECIFICATIONS MAX LOAD: 55 psf Roof Load, 170 mph, ASCE 7-10, 29'-0" Mean Height, Exp. B, C or D. W Mde Xwy Eptv¢Mp G 916� 9 ust 9ume BM. A TYPICAL ALTERNATE BRACING DETAIL STDTL14 April 11, 2016 FO EXTERIOR FLAT GIRDER TRUSS A-1 ROOF TRUSSES 4451 ST..LCIEBLVDU 12 L 6FORT PIERCE,F49 772-409.1010 VARIES (4) 12d TRUSS 2411 O.C. (4) 12d UPLIFT CONNECTION (SEE ROOF TRUSS) EXTERIOR FLAT GIRDER MAX 3011(2'-6") 2x6 #2 SP (Both Faces) 2411 O.C. SIMPSON H5 FEBRUARY 17, 2017 STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND STDTLI5 DAMAGED OR MISSING CHORD SPLICE PLATES A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 3 TOTAL NUMBER OF NAILS EACH SIDE OF BREAK * X (INCHES) MAXIMUM FORCE (LBS) 157 LOAD DURATION SP OF SPF HF 20 2X6 2X4 2X6 2X4 2X6 2X4 2X6 2X4 2X6 20 30 24' 1706 2559 1561 2342 1320 1980 1352 2028 26 39 30' 2194 3291 20D7 3011 1697 2546 173E 2608 32 48 36' 2681 4022 2454 3681 2074 3111 2125 3187 38 57 42' 3169 4754 2900 4350 2451 3677 2511 3767 44 66 48' 3657 5485 3346 5019 2829 4243 2898 4347 • DIVIDE EQUALLY FRONT AND BACK ATTACH 2X_ SCAB OF THE SAME SIZE AND GRADE AS THE BROKEN MEMBER TO EACH FACE OF THE TRUSS ( CENTER ON BREAK OR SPLICE) WITH 10d NAILS (TWO ROWS FOR 2X4, THREE ROWS FOR 2X6) SPACED 4' O.C. AS SHOWN (131' DIA. X 3'). STAGGER NAIL SPACING FROM FRONT FACE AND BACK FACE FOR A NET 2' D.C. SPACING IN THE MAIN MEMBER. USE A MIN. 3' MEMBER ENO DISTANCE. THE LENGTH OF THE BREAK (C) SHALL NOT EXCEED 12'. (C=PLATE LENGTH FOR SPLICE REPAIRS) THE MINIMUM OVERALL SCAB LENGTH REOUIREO (L) IS CALCULATED AS FOLLOWS: L = (2) X + C VA • 10d NAILS NEAR SIDE + IOd NAILS FAR SIDE TRUSS CONFIGURATION AND BREAK LOCATIONS FOR ILLUSTRATIONS ONLY 6' MIN THE LOCATION OF THE BREAK MUST BE GREATER THAN OR EQUAL TO THE REQUIRED X DIMENSION FROM ANY PERIMETER BREAK OR HEEL JOINT AND A MINIMUM OF 6' FROM ANY INTERIOR JOINT (SEE SKETCH ABOVE). DO NOT USE REPAIR FOR JOINT SPLICES NOTES: 1. THIS REPAIR DETAIL IS TO BE USED ONLY FOR THE APPLICATION SHOWN. THIS REPAIR DOES NOT IMPLY THAT THE REMAINING PORTION OF THE TRUSS IS UNDAMAGED. THE ENTIRE TRUSS SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED. WHEN THE REQUIRED REPAIRS ARE PROPERLY APPLIED, THE TRUSS WILL BE CAPABLE OF SUPPORTING THE LOADS INDICATED. 2. ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLYING REPAIR AND HELD IN PLACE DURING APPLICATION OF REPAIR. 3. THE ENO DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 4. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. S. THIS REPAIR IS TO BE USED FOR SINGLE PLY TRUSSES IN THE 2X_ ORIENTATION ONLY. 6. THIS REPAIR IS LIMITED TO TRUSSES WITH NO MORE THAN THREE BROKEN MEMBERS. FEBRUARY 17, 2017 1 SCAB APPLIED OVERHANGS I STDTLI6 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 3494 772409-1010 SEP 12 2019 ST. Lucie County, Permitting TRUSS CRITERIA: LOADING: 4D-10-D-10 DURATION FACTOR: I15 SPACING: 24' D.C. TOP CHORD: 2X4 OR 2X6 PITCH: 4/12 - 12/12 HEEL HEIGHT: STANDARD HEEL UP TO 12' ENERGY HEEL END BEARING CONDITION NOTES: 1. ATTACH 2X_SCAB (MINIMUM #2 GRADE SPF, HF, SP, OF) TO ONE FACE OF TRUSS WITH TWO ROWS OF 10d COMMON WIRE NAILS (148' DIA. X 3') SPACED 6' D.C. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. 2X SC NOTE: TRUSS BUILT WITHOUT AN OVERHANG. THIS DETAIL IS NOT TO BE USED WHEN OVERHANG HAS BEEN BROKEN OFF. IMPORTANT THIS DETAIL TO BE USED ONLY WITH TRUSSES (SPANS LESS THAN 401 SPACED 24' O.C. MAXIMUM AND HAVING PITCHES BETWEEN 4/12 AND 12/12 AND TOTAL TOP CHORD LOADS NOT EXCEEDING 50 PSF. TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY.