MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidadc.eovleconomv
ICP Adhesives and Sealants, Inc.
12505 NW 44th Street SCANNED —Coral Springs, FL. 33065 BY
SCOPE: St. Lucie County
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
L
EIVED
13'019
ountyCPermittla9_
DESCRIPTION: ICP Adhesives Polyset® AH-160
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been Fled and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at thejob site at the request of the Building Official.
This NOA renews NOA 16-0315.01 and consists of pages 1 through 11.
The submitted documentation was reviewed by Alex Tigera.
file Cr►Y�-`
NOA No.: 17-0322.03
MIAMI-DADE COUNTY
' 22
REVIEWED FOR Expiration Date: ate 04/27/17
Approval Date: 04/27/17
CODE COMPLIANCE Page 1 of 11
ST. LUCIE COUNTY
ROCC
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described
in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable
building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing
Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP
Adhesives Polysete AH-160.
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test Product Description
Specifications
ICP Adhesives N/A
Polyset®AH-160
ICP Adhesives Foam N/A
Dispenser RTF1000
ICP Adhesives ProPack® N/A
30 & 100
TAS 101 Two component polyurethane foam adhesive
PRODUCTS MANUFACTURED BY OTHERS:
Dispensing Equipment
Dispensing Equipment
Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment
resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive.
MANUFACTURING LOCATION:
Tomball, TX.
PHYSICAL PROPERTIES:
Prone
Test
Density
ASTM D 1622
Compressive Strength
ASTM D 1621
Tensile Strength
ASTM D 1623
Water Absorption
ASTM D 2127
Moisture Vapor Transmission
ASTM E 96
Dimensional Stability
ASTM D 2126
Closed Cell Content ASTM D 2856
Results
1.6 lbs./ft.3
18 PSI Parallel to rise
12 PSI Perpendicular to rise
28 PSI Parallel to rise
0.08 Lbs./Ft2
3.1 Perm / Inch
+0.07% Volume Change @ -401 F., 2 weeks
+6.0% Volume Change @1580F., 100% Humidity, 2
weeks
86%
Note: The physical properties listed above are presented as typical average values as determined by
accepted ASTM test methods and are subject to normal manufacturing variation.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 2 of 11
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report
Date
Center for Applied Engineering
#94-060
TAS 101
04/08/94
257818-IPA
TAS 101
12/16/96
25-7438-3
SSTD 11-93
10/25/95
25-7438-4
25-7438-7
SSTD 11-93
11/02/95
25-7492
SSTD 11-93
12/12/95
Miles Laboratories
NB-589-631
ASTM D 1623
02/01/94
Polymers Division
Ramtech Laboratories, Inc.
9637-92
ASTM E 108
04/30/93
Southwest Research Institute
01-6743-011
ASTM E 108
11/16/94
01-6739-062b[1]
ASTM E 84
01/16/95
Trinity Engineering
7050.02.96-1
TAS 114
03/14/96
P36700.04.12
ASTM D 1623
04/18/12
P39740.02.12
TAS 101
02/21/12
TAS 123
Celotex Corp. Testing Services
528454-2-1
TAS 101
10/23/98
528454-9-1
528454-10-1
520109-1
TAS 101
12/28/98
520109-2
520109-3
520109-6
520109-7
520191-1
TAS 101
03/02/99
520109-2-1
LIMITATIONS:
1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating.
2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive
with their tile assemblies shall test in accordance with TAS 101.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 3 of 11
INSTALLATION:
1. ICP Adhesives Polyset® AH-160 maybe used with any roof tile assembly having a current NOA that lists
attachment resistance values with the use of ICP Adhesives Polyset® AH-160.
2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the
corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP
Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value
determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive
attachment data is noted in the roof tile assembly NOA.
3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance with Roofing Application
Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and
Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having
jurisdiction.
5. Calibration of the ICP Adhesives Foam Dispenser RTF1000 dispensing equipment is required before application
of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between
1.0-1.15 (A): 1.0 (B).
6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF 1000 or ICP
Adhesives ProPack® 30 & 100 dispensing equipment only.
7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight.
S. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives
Polyset® AH-160 has been dispensed.
9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accordance with the
'Placement Details' herein. Each generic tile profile requires the specific placement noted herein.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 4 of 11
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile
Placement Detail
Minimum Paddy Contact
Minimum Paddy Gram
Area
Weight
Eave Course - Flat, Low, High
Profiles
All Eave Course
17-23 s inches
q
45-65
Flat, Low, High Profiles
#1
17-23 sq. inches
45-65
-Flat-Profile
#2
10-12 sq. inches
M
Low Profile
#2
' 12-14 sq. inches
30
High Profile
#2
17-19 sq. inches
30
Flat, Low, High Profiles
#3
Two Paddys: 8-9 sq. inches at
12 grams per paddy
head of tile 9-11 sq. inches at
overlap
Two -Piece Barrel (Cap Tile)
Two Piece
2 Beads (1 each longitudinal
17 grams per bead
edge) 20-25 sq. inches each
bead
Two Piece Barrel (Pan Tile)
Two Piece
65-70 sq. inches
34 grams under pan
LABELING:
All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami -
Dade County Product Control Seal as shown below.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 5 of 11
10
loon.Ilk
eemew
ADHESIVE PLACEMENT DETAIL # 1
la.n..th Td.l
law Oosula
Fasda
NMI Ih+vugh pl.IniC w
(whenwquised) el 1,Paddy to.n..lhriol
d..f•ylrwnt .,
�.
i1n.w
21n.wda \
galtens
aptichat
f Fr C.Une
Falda
hSFee.
10 (R �7 in. Fs.e closos ure
,y Dripodge
MIAMI•DADE COUNTY
Flat/Low Profile Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown,
under the strengthening rib closest to the overlook
of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm2)-23 (148.4 cmZ) square inch adhesive
contact with the underside of the tile.
Medium Profile / Double Pan Tile
1, Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlook of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cmZ) — 23 (148.4 cm) square inch adhesive
contact with the underside of the tile.
High Profile / Single Pan Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlock of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm) —23 (148.4 cm2) square inch adhesive
contact with the underside of the tile.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 6 of 11
opaonal
4 21
�tnt
ADHESIVE PLACEMENT DETAIL # 2
i.4.anw�.
Nodw
Flat/Low Profile Tile
Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
strengthening rib of the tile closest to the overlock of
the tile being set. Insure approximately 17 (109.7 cm2)
— 23 (148.4 cm2) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the
strengthening rib closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 10"
(64.5 cm2) - 12 (77.4 cm2) square inch adhesive
contact with the underside of the tile.
Medium Profile / Double Pan Tile
Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cm2) —
23 (148.4 cmZ) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 12"
(77.4 cm2) - 14 (90.3 cm2) square inch adhesive
contact with the underside of the tile.
(Instructions continued on next page)
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 7 of 11
optlaaal
10
ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED)
edge
High Profile / Single Pan Tile
Starting at the cave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cm2) —
23 (148.4 cm2) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overlook of the tile
being set.
3. Continue in same manner. Insure approximately 17"
(109.7 cm2) - 19 (122.6 cm2) square inch adhesive
contact with the underside of the tile.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 8 of 11
In.
s 41n.
ADHESIVE PLACEMENT DETAIL # 3
Flatkow Profile Tile
Wdlum PrafileTlle
(between taesl
Ewe(3 s re
I. On the eave course only, apply a minimum 2" (50.8
mm) x 10" (254 mm) x V (25.4 mm) foam paddy
onto the underlayment positioned as shown, under
the strengthening rib for flat tile or under the pan
portion of the tile for low or high profile tile closest
to the overlock of the tile being set. Leave
approximately 4" (101.6 mm) up from the cave
edge free of foam to prevent the expanded adhesive
from blocking the weep holes. Insure
approximately 17-23 in' (109.7-148.4 cm') of
adhesive contact with the underside of the tile
2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x 1" (25.4
mm) foam paddy onto the underlayment just below
the second course line positioned foam paddy
under the strengthening rib for flat tile, or under the
pan portion of the tile, closest to the underlock for
the second course tile to be installed. Insure
approximately 8-9 in' (51.6-58.1 cmz) of adhesive
contact with the underside of the tile.
(Instructions continued on next page)
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 9 of 11
ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED)
IM
loin 2
High ProOleTile
MIAMI•DADE COUNTY
I9 1
3. Also apply a 211(50.8 mm) x 4" (101.6 mm) x %"
(19 mm) paddy on top of the eave course tile
surface as shown, on top of the strengthening rib
for flat tile or on top of the pan portion of the tile,
closest to the underlock of the first course of tile.
Install second course of tile. Insure approximately
9 (58.1 cml) - 11 (71 cm2) square inch adhesive
contact with the underside of the tile at the overlap
and 7 (45.2 cm') - 9 (58.1 cm') square inch
adhesive contact with the underside of the tile at
the head of the tile. Continue in same manner.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 10 of 11
1) Place enough adhesive to achieve 65 to 70 sq.
In contact with the pan tile.
2)Tom covers upside down. Place adhesive In
to t In. from outside edge ofcovertile.
Then Install the tile. Ensure 20 to
25 sq•In. contact area.
Eave closure
(motarshown)
ADHESIVE PLACEMENT DETAIL
TWO PIECE BARREL
eava course cover tile. Abut to second course of
d pan and covertlles are flush at save line.
Two Piece Barrel - High Profile Tile
Two Piece Barrel (Cap and Pan) Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as
shown under two adjacent pan tiles. Support eave
tiles from rocking until adhesive has a chance to
cure.
2. Continue in same manner bringing two pan
courses up toward the ridge. Insure
approximately 65 (419.4 cm') — 70 (451.6 cm2)
square inch adhesive contact with the underside
of the pan tile.
3. Turn covers upside down exposing the underside
of the tile. Apply a minimum 1" (25.4 mm) x 10"
(254 mm) bead of adhesive directly on the inner
edge of each side of the cover tile. Leave
approximately 3/4" (19 mm) to 1" (25.4 mm)
from the outside edge of the tile, inward, free of
foam to allow for expansion.
4. Turn cover tile over after foam is applied and
place onto pan tile course. Insure a minimum of
20 (129 cm2) - 25 (161.3 cm') square inch
contact area on each side of the cover tile to the
pan tile. Continue in same manner. Trim away
any cured exposed foam adhesive. Pointing of
longitudinal edges of the cover tiles are
considered optional.
5. When additional nailing is required, 2" (50.8
mm) x 4" (101.6 mm) nailers or the tie wire
system using galvanized, stainless steel, or
copper wire and compatible nails may be used.
END OF THIS ACCEPTANCE
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 11 of 11
RECEIVED
SEP 13 ^0'9
MIAMI•DADE
ST. Lucie County, Permitting
'®
MIAMI-DADE COUNTY
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
PRODUCT CONTROL SECTION
11805 S W 26 Street, Room 208
Miami, Florida 33175-2474
NOTICE OF ACCEPTANCE
(NOA)
T (786) 315-2590 F (786) 315-2599
www.miamidade.pov/economy
Boral Roofing, LLC
SCANNED
7575 Irvine Center Drive, Suite 100
��
Irvine, CA 92618
St. Lucie County
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
'including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Barcelona 900 Concrete Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION'of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or'process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 18-0509. 15 and consists of pages 1 through 7.
The submitted documentation was reviewed by Freddy Semino -vile C
MIAMI-DADECOUNTr REVIEWED FOH NOA No.: 19-0408.02
ZI 0 1 Expiration Date: 04/26/22
CODE COMPLIAIVC,. Approval Date: 05/16/19
ST. LUCIE COUNTS ' Page 1 of
SOCC
ROOFING ASSEMBLY APPROVAL
Category:
Roofing
Sub -Category:
Roofing Tiles
Material:
Concrete
I. SCOPE
This approves a roofing system using Barcelona 900 Concrete Roof Tile, as manufactured Boral Roofing LLC
in Lake Wales, FL and described this Notice of Acceptance. For locations where the pressure requirements, as
determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in
compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations
shall be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Applicant Dimensions
Barcelona 900 Length = 17"
Width= 13"
? thick
Test
Specifications
Product
Description
TAS 112 High profile, interlocking, one-piece, 'S' shaped,
Type —1 a high-pressure extruded concrete roof tile
equipped with three nail holes. For direct deck
or battened nail -on, mechanically fastened,
mortar set or adhesive set applications.
Trim Pieces Length: varies TAS-112 Accessory trim, boosted Barcelona, concrete
Width: varies roof pieces for use at hips, rakes, ridges and
varying thickness valley terminations manufactured for each tile
profile.
2.1 PRODUCTS MANUFACTURED BY OTHERS
Product Name
ICP Adhesives Polyset® AH-160
TILE BONDTM Roof Tile Adhesive
DAP Foam Touch N Seal
StormBond02 Roof Tile Adhesive
Product Description
Two component polyurethane
foam adhesive.
Single component polyurethane
foam roof tile adhesive.
Two component polyurethane
foam adhesive.
2.2 MANUFACTURING LOCATION
2.2.1. Lake Wales, FL
Manufacturer
(With Current NOA)
ICP Adhesives and Sealants, Inc.
The Dow Chemical Company
Dap Foam Inc.
MIAMI-DADECOUNTY NOA No.: 19-0408.02
Expiration Date: 04/26/22
Approval Date: 05/16/19
Page 2 of 7
2.3 SUBMITTED EVIDENCE:
Test Agency
Test Identifier
Test Name/Report
Date
Redland Technologies
7161-03
Static Uplift Testing
Dec. 1991
Appendix III
TAS 102 & TAS 102(A)
Redland Technologies
7161-03
Wind Tunnel Testing
Dec. 1991
Appendix II
TAS 108(Nail-On)
Redland Technologies
P0402
Withdrawal Resistance
Sept. 1993
Testing of screw vs. smooth
shank nails
Redland Technologies
Letter Dated Aug. 1,
Wind Tunnel Testing
Aug. 1994
1994
TAS 108 (Nail -On)
Redland Technologies
P0631-01
Wind Tunnel Testing
July 1994
TAS 108 (Mortar Set)
Professional Service Industries, Inc.
IC-1320-94
Physical Properties
Feb. 1995
TAS 112
The Center for Applied Engineering, Inc.
25-7688-3
TAS 101 (Adhesive Set)
June 1996
25-7688-10
TAS 101 (Mortar Set)
July 1996
The Center for Applied Engineering, Inc.
25-7688-5
Static Uplift Testing
June 1996
TAS 102
(3" Headlap, Nails, Direct
Deck, New Construction)
The Center for Applied Engineering, Inc.
25-7688-4
Static Uplift Testing
June 1996
TAS 102
(4" Headlap, Nails, Clips)
Celotex Corporation
520111-3
Static Uplift Testing
Dec. 1998
Testing Services
520191-2-1
TAS 101
March 1999
Walker Engineering, Inc,
Calculations
Aerodynamic Multiplier
09/01/16
Walker Engineering, Inc.
Evaluation
Restoring Moments Due to
09/01/16
Calculations
Gravity
American Test Lab of South Florida
RT0617.03-16
TAS 112
06/29/16
PRI Construction Materials Technologies
COPO-002-02-10
Static Uplift Testing
10/12/2016
TAS 101 (Adhesive Set)
PRI Construction Materials Technologies
COPO-002-02-02
Static Uplift Testing
10/12/2016
TAS 101 (Adhesive Set)
PRI Construction Materials Technologies
COPO-002-02-01
Static Uplift Testing
10/12/2016
TAS 101 (Adhesive Set)
NOA No.: 19-0408.02
Expiration Date: 04/26/22
Approval Date: 05/16/19
Page 3 of 7
3. LIMITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 10.6 may
require, refer to applicable building code.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in
accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Department of Regulatory
and Economic Development — Product Control Section for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
4. INSTALLATION
4.1 Barcelona 900 Concrete Roof Tile and its components shall be installed in strict compliance with Roofing
Application Standard RAS 118, RAS 119, and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile
Weight-W (lbf)
Length-1 (ft.)
Width-w (ft.)
Barcelona 900
11.5
1 1.417
1.08
Table 2: Aerodynamic Multipliers -A (ft3)
Tile Profile
A (ft3)
Batten Application
A (ft3)
Direct Deck Application
Barcelona 900
0.286
0.301
Table 3: Restoring Moments due to Gravity - Me (ft.-lbf)
Tile
2":12"
3":12"
4":12"
5":12"
6":12"
7":12" or
Profile
greater
Barcelona
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
900
Deck
1
Deck
Deck
1
Deck
Deck
Deck
6.19
7.07
6.19
7.00
6.19
6.90
6.06
1 6.76
5.92
6.60
5.76
6.42
M64MMADE COUNTY
,..mi
NOA No.: 19-0408.02
Expiration Date: 04/26/22
Approval Date: 05/16/19
Page 4 of 7
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Mechanically Attached Systems
Tile
Fastener Type
Direct Deck
Direct Deck
Battens
Profile
(min 15/32"
(min. 19/32"
plywood)
plywood)
Barcelona 900
2-10d Rinn Shank Nails
28.6
41.2
19.4
1-10d Smooth or Screw Shank
5.1
6.8
2.8
Nail
2-10d Smooth or Screw Shank
6.9
9.2
7.3
Nails
1 #8 Screw
20.7
20.7
18.1
2 #8 Screw
43.2
43.2
29.8
1-10d Smooth or Screw Shank
23.1
23.1
19.0
Nail Field Clip)
1-10d Smooth or Screw Shank
29.3
29.3
24.0
Nail Eave Clip)
2-10d Smooth or Screw Shank
27.6
27.6
38.6
Nails Field Clip)
2-10d Smooth or Screw Shank
38.1
38.1
41.8
Nails Eave Clip)
Table 5: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Mechanically Attached Systems
Tile
Fastener Type
Direct Deck
Direct Deck
Battens
Profile
(min 15/32"
(min. 19/32"
plywood)
plywood)
Barcelona 900
2-10d Ring Shank Nails'
33.1
48.1
45.2
1 Installation with a 4" the headlap and fasteners are located a min. of 2%" from head of tile.
Table 6: Attachment Resistance Expressed as a Moment Mf (ft-lbf)
for Two Paddy Adhesive' Set Systems
Tile
Tile Application
Minimum Attachment
Profile
Resistance
Barcelona 900
Tile BondTM One Component Roof Tile Adhesive
29.32
�P Adhesives V g'- rYH'fl 0ttyo-component foam
29.33
r
�,
DAP Foam Touch N S al ormBond® 2 Roof Tile Adhesive
66"
1 See manufactures component approval for installation requirements.
2 TILE BONDT1A Roof Tile Adhesive; Average weight per paddy 10.7 grams.
3 ICP Adhesives and Sealants, Inc.'s ICP Adhesives Polyset AH-160; Average weight per paddy 8 grams.
4 DAP Foam Touch N Seal StormBond® Roof Tile Adhesive Two -Component; Average weight per paddy 6 grams.
NOA No.: 19-0408.02
Expiration Date: 04/26/22
Approval Date: 05/16/19
Page 5 of 7
Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf)
for Single Paddy Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Barcelona 900
ICP Adhesives Polyset® AH-160 two -component foam
66.55
ICP Adhesives Polyset® AH-160 two -component foam
38.76
DAP Foam Touch N Seal StormBond®2
63 r
DAP Foam Touch N Seal StormBond®2
828
5 La r a paddy placement
of 63 grams
6 Medium paddy
placement of 24 grams
7 Medium paddy
placement of 30 grams
8 Large paddy placement
of 60 grams
Table 8: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf)
for Mortar Set Systems
Tile
Profile
Tile
Application
7 Attachment
Resistance
Barcelona 900
Mortar Set9
24.5
9 Seespecific mortar manufacturers Notice of Acceptance
5. LABELING
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed
below, or following statement: "Miami -Dade County Product Control Approved".
S
LABEL FOR BARCELONA 900 TILE (LAKE WALES FL PLANT 2)
LOCATED UNDERNEATH TILE
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building code in order to
properly evaluate the installation'of this system.
NOA No.: 19-0408.02
Expiration Date: 04/26/22
Approval Date: 05/16/19
Page 6 of 7
PROFILE DRAWING
518 "
m
BARCELONA 900 CONCRETE ROOF TILE
END OF THIS ACCEPTANCE
NOA No.: 19-0408.02
MIAMIDADE COUNTY
,..., , Expiration Date: 04/26/22
Approval Date: 05/16/19
Page 7 of 7