HomeMy WebLinkAboutPOOL HEAT PUMPULTRATEMP° HEAT PUMPS
HIGH PERFORMANCE HEAT PUMP
MW771 7
• 100% pure titanium heal exchanger assures corrosion -free performance
for extra long life
• LCD control board displays an intuitive menu.driven read out with easy
to follow full word messages —no more codes
• Autos et[time clock over -ride) feature monitarswater temperature
and turns the water circulation pump on and off as needed to maintain
desired pool temperatures
• Automatic defrost feature senses refrigerant o parature and prevents
t
freezing, allowing the heal pump to operate at even lower temperatures
• Compatible with ALL automated control packages
• Long -life corrosion resistant plastic composite cabinet stands up to
severe climates and pool chemicals
• Emersono Copeland Scroll- Compressor on 60 Hz, single phase models
• ETL listed for safe operation
• Thermostatic Expansion Valve ITXVJ controls refrigerant flow for
optimum efficiency and BTU output overa wider operating range
• Highest efficiency available, meals or exceeds existing codes
and standards
• BTU and efficiency performance independently certified by the
Air -Conditioning. Healing and Refrigeration Institute, AHRI
BY
St Lucip rnnnfi/
s
UltraTemp Heat Pumps
The industry's first heat pump charged with
non -ozone depleting refrigerant, R410A.
Ordering Information
Part Model 80/80/80• BO/63180•• 50/63/80•• Freq Breaker BLACK Wire
. ACK ALMOND BTU/COP BTU/COP BTU/COP (Hz( Size Phase Wire
sizVolt Cut Ctn 'A'
(amp) Oly. Wt. Dim.
460960 460930 70 75,000/5.8 70,000/5.7 50.000/4.1 - -60 40 1 10 230 1 230 33.5
460961 460931 90 90.000/5.7 84,DDO/5.5 60.000/4.0 60 s0 1 8 230 1 250 33.5
460962 460932 110 108,000/6.0 101.000/5.8 72.000A.0 60 50 1 8 230 1 270 45.5
460963 460933 120 127.000/5.7 120.000/5.5 82,000/4.0 60 50 1 8 230 1 270 45.5
460964 460934 140 143.00015.8 134.000/5.6 88.000/4.0 60 50 1 8 230 1 32D 45.5
460965 460935 120 H/C I27.000 Heat/5.6 120.000/5.4 82.000/4.0 60 So 1 8 230 1 278 45.5
71.000 Coal/4.1
d146(1954 p Sg 14C6014-.f 5=0140
460936 0 o_ S13234.5
N/A '
85.00015.7 81.000/5.4 56.000/4.0 50 30 3 10 380 1 250 33.5
460967 460937 120 C 123.000/9.6 115.000/5.3 81.000/4.0 60 50 3 8 230 1 280 45.5
N/A 460938 1001 102.000/5.9 96.000/5.6 67.000/4.0 50 s0 1 8 230 1 280 41.5
460929 460928 140C 140.000/5.8 132,000/5.6 86.000/4.0 60 so 3 8 230 1 320 45.5
'Rating outside the scope of ARl Standard 1160[air temp.•F./%relative Emerson -is a registered trademark of Emerson Electric Co. and Copeland
humidity/water temp •F.I Scroll'is a registered trademark of Emerson Climate Technologies, Inc.
'• Rating in accordance with ARI Standard 1760 fair temp. •F. /%relative
humidity /waterlemp'F.] Dimensions and Performance
L--mmm
c ETA
The AHRI Certified" Mark is appliepirty
to HVACR equipment and components that
have been independently tested to certify
manufacturers' performance claims are
accurate. Visit www.ahridirectory.org for a
complete list of certified products.
CEC indicates that Heal Pump has been evaluated
to California Title-20, listed in the California
Energy Commission's ICECI database of compliant
heat pumps• and certified to use on Residential
Swimming Pool Filtration Systems.
See pages 453-454 for replacement parts.
INSTALLATION AND LOCATION
®CAUTION When pool equipment is located below the pool surface, a leak from any component can cause large scale water loss or flooding.
Pentair Water Pool and Spa, Inc. cannot be responsible for such water loss or flooding which may cause damage to property or
to the product. Avoid placing the heat pump in locations where it can cause damage by water or condensate leakage. If this is not possible, provide a
suitable drain pan to catch and divert any leakage.
Only a qualified service person should install the
UltraTempe Heat Pump. Before installing this product,
refer to the Important Warning and Safety instructions
on page ii.
Materials Needed for Installation
The following items are needed and are to be supplied
by the installer for all heat pump installations:
1. Plumbing connections (2-inch).
2. Level surface for proper drainage.
3. Suitable electrical supply line. See rating plate on
unit for electrical specifications. A junction box is not
needed at the heat pump; connections are made
inside of the heat pump electrical compartment.
Conduit may be attached directly to the heat pump
jacket.
4. Electric cutout switch that will interrupt all power to
the unit. This switch must be within line of sight of
the heat pump. Check local codes for requirements.
5. Watertight conduit to run the electrical supply line.
Equipment Pad
For proper drai page of condensation and rainwater, place
the heat pump on a flat slightly pitched surface, such as
a concrete or fabricated slab (pad).
If possible, place the pad at the same level or slightly
higher than the filter system equipment pad.
Note: Be sure that the pad is pitched not more than 114
in. per foot in any direction as needed for runoff.
Heat Pump Dimensions
MODELS DIMENSION "A"
70,90 33.5" (851 mm)
110, 120, 120C, 140C 45.5" (1156 mm)
120 H/C, 140,140 WC
Drainage and Condensation
Condensation occurs from the evaporator coil while the
unit is running, and drains at a steady rate (usually three
to five gallons per hour), depending upon ambient air
temperature and humidity. The more humid the ambient
conditions, the more condensation will be produced.
The bottom of the unit acts as a tray to catch rainwater
and condensation. Keep the drain holes, located on the
bottom pan of the base of the unit, clear of debris.
Roof Run-off
Make sure the heat pump is not located where large
amounts of water may run-off from a roof into the unit.
Sharp sloping roofs without gutters will allow massive
amounts of rain water, mixed with debris from the roof
to be forced through the unit. A gutter or down spout
may be needed to protect the heat pump.
Lawn Sprinklers
Avoid placing lawn sprinkler near the heater -
they can spray water into the heater and void the
warranty. Be sure to direct any spraying water away
from the heater. Note the wind direction to be sure
water from sprinklers is not blown toward the heater.
Sprinkler heads can produce high water pressure and
spray at an angle, different from typical rain and humid
weather. Also, sprinklers connected to a well water
system can cause mineral build up on the evaporator
coils and electronics. Salt water can also be an issue if
located near the coast.
ULTRATEMP® Heat Pump Installation and User's Guide
u
Location and Clearances
All criteria given in the following sections reflect minimum
clearances. However, each installation must also be
evaluated, taking into account the prevailing local
conditions such as proximity and height of walls, and
proximity to public access areas.
The UltraTemp® Heat Pump must be placed to provide
clearances on all sides for maintenance and inspection.
1. At least 24 in. [610 mm] access must be available in
the front and 12 in. [305 mm] on all the other sides
of the heat pump for service and proper air flow.
(Manufacturer's recommendation).
Anchor Clamp Installation
2. If the heat pump is to be installed under a cover
or under a vertical overhang, the unit must have
a minimum of five (5) feet [1.52 m] clearance
from the top of the heat pump. (Manufacturer's
recommendation).
3. Install a minimum of five (5) feet [1.52 m] from the
inside wall of the pool or spa unless the heat pump
is separated from the pool or spa by a five (5)
foot [1.52 m] high solid fence or other permanent
barrier. Canadian installations require a minimum
of three (3) meters [9.84 ft] from pool water.
4. Install heat pump a minimum of 6 in. [153 mm] from
Heat Pump Location and Clearances
Installation of the anchor clamps is recommended in
all installations. Installation of the anchor clamps is
required in Florida (see Florida Building Code 301.13).
Anchor clamps hold the heat pump to the equipment
pad in order to withstand high winds caused during
extreme weather (i.e. hurricanes).
To install the anchor clamps:
1. Be sure the heat pump is in its permanent location
on the equipment pad. Heat
2. Place the clamps at the base of the heat pump in CIE
the four (4) locations, shown in the image to the
right.
Note: Bolts and bolt anchors are not included with
the heat pump. The installer must provide 1/4" x
1-3/8" stainless steel anchor bolts and the appro-
priate size concrete anchor to mount the clamp to
the equipment pad. Be sure to check local codes.
3. Fit the hook of each clamp over the lip on the
base panel of the heat pump. The hook should fit
between the lip of the base panel and the evapo-
rator coil guard.
Pump
mps
Anchor Clamp Installation
ULTRATEMP° Heat Pump Installation and Users Guide
or4
Anchor Clamp Installation, Continued
4. Mark the position of the hole in each clamp on the
equipment pad.
5. Use a masonry drill bit and drill a hole in the cement
with a diameter as determined by the concrete
anchor, at each of the marks on the equipment pad.
The hole should be approximately 1% in. deep.
6. Insert a bolt anchor into each of the holes. Be sure
the anchors are set completely into the holes.
7. Position the anchor clamps so that the holes in the
clamps are over the bolt anchors.
Be sure that the clamp hooks are over the lip of the
heat pump base.
8. Insertan anchorbokthrough each clamp intothe anchor
and tighten to secure the clamp and heat pump to
the equipment pad.
Anchor Clamp Installation
Water Connections and Plumbing
The image below shows the standard plumbing layout
with a single UltraTemp® Heat Pump unit. Follow the
image from right to left for the standard plumbing
sequence.
Arrangement of pool system components (other than the
standard plumbing image below), and the location of the
heat pump (above or below the pool water surface) can
affect the operation of the heat pump's water pressure
switch.
The pressure switch can be adjusted to accommodate
this effect if the heat pump water connections are no
more than six (6) feet [1.82 m] below the pool water
surface.
See instructions for pressure switch adjustment on page
6. If the heat pump is installed outside of this range, an
external pressure switch may need to be installed in the
plumbing upstream of the heat pump.
Note: Be advised that when pool equipment is located
below the pool surface a leak can result in large-scale
water loss or flooding. Pentair is not responsible for such
water loss or flooding or damage.
Automatic Flow Control Valve
The inlet/outlet header of the heat pump comes equipped -
with an internal automatic flow control valve. The
automatic flow control valve maintains the proper flow
through the heat pump at rates up to 120 gpm (456 Ipm).
If the filter system flow rate is higher than 120 gpm (456
Ipm), install a manual bypass valve, see image below.
Note: Be advised that if your circulation pump is over 2
HP or if the total flow exceeds 120 gpm (456 Ipm), you
will have to add an external bypass valve. Excess water
flow will damage the heat exchanger.
Standard Plumbing Layout
ULTRATEMP° Heat Pump Installation and User's Guide
L7
TECHNICAL DATA
Pump Dimensions
5bin
10.8in ° [142mm]
i
[275mm] � 1, ® _
2.8in
[71mm] 7.8in
23.4in
11
[301
Electrical Specifications
Circuit Protection: Two -pole 20 AMP device at the Electrical Panel.
Input: 230 VAC, 50/60 Hz, 3200 Watts Maximum, 1 phase
Pump Performance Curves.
INTELLIFLOOVSFVariabte Speed and Flow Pump Instattation and User's Guide
8/23/2017
Pentair- Ctean and Clear Cartridge Fllters
Y
Flow Turnover Capacity (In
Rate' Gallons)
Product Model Effective (GPM 8 10 12 Carton Carton
Filtration Area Res) Hour Hour Hour Qty Wt
(Sq. Ft.) (Lbs)
160314
CC 50
50
160315
CC 75
75
160316
CC
100
100
160317
CC
150
150
160318
CC
200
200
1: One GPM per sq. ft. ahmvn recommended Oow rate 0.6 GPM per sq. ft.
50
24,000
30,000
36,000
1
15
75
36,000
45,000
54,000
1
26
100
48,000
60,000
72,000
1
33
150 72,000 90,000 108,000 1 35
150 72,000 90,000 108,000 1 35
https.*IAvw vpentaitpool.com/en/productslfilters/dean%20and%<20clear%20cartddge%2081ters 1h
SECTION IV. TECHNICAL DATA
A. Filter Pressure Loss Chart
PRESSURE LOSS yr FLOW
C. Replacement Parts
B. Flow Rate Table
Residential
Maldmum Cartridge
Flow Rates
Commercial
Maldmum Cartridge
Flow Rates
Pmduct 1
sq. M
GM
GPH
6 hour
8 hour
GPY
GPH
6 hour
6 hour
160314
5o
50
3,000
18,000
24,000
19
1,140
6,840
9,120
lemis
76
75
4,500
27,000
36.000
28
1,69D
10,080
13A40
160316
100
100
6,000
36,000
48,000
38
228D
13,680
18240
160317
1601
150
9,0D0
64,000
72,000
56
3,360
20,160
Z6,BB0
160318
200
F 160
9,0D0
64,000
72,0W
75
4,500
27,000
36,000
(1) one GPM per sq. ft. show0, recommended flow rate for residential is .5 GPM per sq. ft.
(2) Commercial flow rate is a maximum of.375 GPM per sq. fL of fdter area
NOTE: Actual system flow will depend on plumbing size and other system components.
Item
Part Number
Description
1
98209800
High Flow" manual air relief valve
2
190058
Pressure Gauge
3
178553
Lid, 50,100 sq. ft filter
4
178561
Lid, 75,150, 200 sq. fL fitter
5
59052900
Locking Ring assy.
6
87300400
Body firing
7
59016200
Air Bleed Sock I(lt
8
59053500
Center Core, 50 sq. ft. fitter
9
59053600
Center Core, 75 sq. ft filter
10
59053700
Center Core, 100 sq. k fitter
11
59053800
Center Core,150, 200 sq. ft. finer
12
R173213
Cartridge Element, 50 sq. ft. filter
13
R173214
Cartridge Element, 75 sq. It filter
14
R173215
Cartridge Element 100 sq. tL filter
15
R173216
Cartridge Element,150 sq. ft. finer
16
R173217
Cartridge Element, 200 sq. ft. fitter
17
178562
Bottom, 50 sq. f . filter
18
17BS54
Bottom, 75 sq. ft. fifter
19
178563
Bottom, 100 sq. fL filter
20
178560
Bottom,150, 200 sq. f . fitter
21
86202000
Drain Cap Assy.
22
51005000
Drain Cap Gasket
23
39104500
Union Nut °C Clip
24
98212200
Union Nut
25
071426
Union 0-ring
26 79304600 Body, Swivel
h��� �I�I�Ii■ O
_L7
Rev. D 6.26-09 7 PM 178556
8W 12017 SmartPool AP72 SolarPill Liquid Ball Solar Blanket Cover for Pools up to 30,000 Gallons
SmariPool AP72 SolarPill Liquid Ball Solar Blanket Cover for Pools up to 30,000 Gallons
View Larger Image
SMARTPOO!
About the SmartPool AP72
The SmartPOol SolarPill (SKU #AP72) is for pools up to 30,000 gallons
and sits on your pool waters surface to help reduce heat and chemical
loss.
Pool Cover Accessory Features:
• One SolarPill for every 30,000 gallons
• Lasts up to one month
• Safe for use in all pool types and sanitization systems
• Will not interfere with chemical balance
k Non Tobc formula is safe for your family and the environment
More Information
SKU: AP72
191�
0 C�
�® 414%t
f4�
0
bp�oo
C; or
The SolarPill is an innovative little product that packs a big punch. This
thermally insulating liquid blanket slowly releases into your filtration,
system and forms a harmless, invisible barrier on the surface of your pool
water to reduce heat and chemical loss by preventing water evaporation.
The advantage of this liquid solar blanket is that it is always working, even
with swimmers in the water. One capsule treats 30,000 gallons for one
month. The SolarPill can be used with traditional chlorine, salt water and
mineral sanitizers. It is safe for use with all types of swimming pools and
will not affect chemical balance.
http://www.pGoisupplyworld.comlSmartPool-AP72-SolarPll-Liquid-BallSolar-Blanket-Cover-fotiPools-up-to-30000-GallonslAP72.htm 1/2
f , BIN2017 SmarlPool AP72 SolarPill Liquid Ball Solar Blanket Cover for Pools up to 30,000 Gallons
SrnartPool AP72 Specifications
Cover Type
Dosage
Item Quantity
Manufacturer
Pool Size
Pool Type
Product Type
Solar Heating System
Solar Cover
1 per 30,000 gallons
Single
SmartPool
Up to 30,000 Gallons
In Ground
Pool Cover Accessory
Solar Chemicals
http://www.poolsupplyworld.coMSmartPool-AP72-SolarPill-Liquid-Ball-Solar-Blanket-Cover-for-Pools-up-to 30000-GallonslAP72.hbm 212