Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE MANOR 71 IMPACT Builder Name: WYNNE BUILDING CORP. ^'� SCANNED Street: THE MANOR 71 c ;r� J Permit Office: ST. LUCIE COUNTY c�ED City, State, Zip: FT. PIERCE, FL, +'�' Owner: WYNNE BUILDING CORP. . `T\b�cf Permit Number: Jurisdiction: BY St. Lucie i minty Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(1654.2 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1374.20 fit' b. Frame - Wood, Adjacent R=11.0 280.00 ftz 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 2 d. NIA R= ft. S. Is this a worst case? Yes 10. Ceiling Types It 724.0 sqft.) Insulation Area p a. Under Attic (Vented) R=30.0 1724.00 ftz 6. Conditioned floor area above grade (ftz) 1724 b. N/A R= ft. Conditioned floor area below grade (ftz) 0 c. N/A R= ft z j 11. Ducts R ftz 7. Windows(153.4 sgft.) Description Area i a. Sup: Attic, Ret: Attic, AH: Attic 6 175 a. U-Factor: Dbl, U=1.04 113.35 ftz SHGC: SHGC=0.29 1I b. U-Factor: Dbl, U=1.00 40.00 ftz 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: NIA ftz j SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a. Electric Heat Pump 34.8 HSPF:8.50. SHGC: Area Weighted Average Overhang Depth: 3.516 ft. i Area Weighted Average SHGC: 0.285 1 14. Hot water systems i ! 8. FloorTypes (1723.5 soft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 1723.50 ftz b. Conservation features EF: 0.950! � b. N/A R= ftz None i a N/A R= ftz 15. Credits Pstat Total Proposed Modified Loads: 53.15 Glass/Floor Area: 0.089 �(a PA SS Total Baseline _oads: 54.03 I ! 1 hereby certify that the plans and specifications covered by Review of the plans and � Ll Srq?A this calculation are in compliance with the Florida Energy specifications covered by this �g Code. calculation indicates compliance ��' "o ri„�''+r' �O II -. with the Florida Energy Code. -_'�°�,o` P PREPARED BY: Before construction is completed r DATE: this building will be inspected for compliance with Section 553.908 * ¢ I hereby certify that this building, as designed, is in compliance Florida Statutes. .yq with the Florida Energy Code. GOrj� OWNER! . BUILDING OFFICIAL DATE:- DATE: - Compliance requires certification by the air handler unit manL facturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection ( hecklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater t Ian 5.00 q (d;A lj3yp14 Wb FOR F� CODE OIi6iRLIANCE C®Comp IE COUNTY ` 9/17/2019 3:13 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2 017 FBC 6th Edition (20011 iant Software Page 1 of 6 FORM, R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE MANOR 71 IM Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1724 Lot # Owner Name: WYNNE BUILDING CORP. Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING CORP. Rotate Angle: 225 Street: THE MANOR 71 Permit Office: ST. LUCIE COUNTY Cross Ventilation. No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume j 1 Entire House 1724 14774.8 i SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated! 1 GREAT ROOM 546 5350.8 No 0 1 Yes Yes Yes i 2 MASTER BEDROO 354 2832 No 2 1 1 Yes Yes Yes 3 WIC 77 616 No 0 1 No Yes Yes 4 CLST. 35 280 No 0 1 No Yes Yes 5 M BATH 54 432 No 0 1 Yes Yes Yes 6 KITCHEN 180 1440 Yes 0 1 Yes Yes Yes 7 JUNIOR M. BED 198 1584 No 0 1 1 Yes Yes Yes 8 BATH 50 400 No 0 1 No Yes Yes 9 POWDER 35 280 No 0 1 Yes Yes Yes 10 NOOK 42 336 No 0 1 Yes Yes Yes 11 LAUNDRY 49 392 No 0 1 Yes Yes Yes 12 ENTRY 104 832 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio GREAT ROOM 47 ft 0 546 ft' 0 1 0 I 2SIab-On-Grade Edge Insulatio MASTER BEDRO 46 ft 0 354 ft' ___ 0 1 0 3 Slab -On -Grade Edge Insulatio WIC 1 ft 0 77 R2 ___ 0 1 0 4 Slab -On -Grade Edge Insulatio CLST. 1 ft 0 35 ft' ---- 0 1 0 5 Slab -On -Grade Edge Insulatio M BATH 9 ft 0 54 ft' _--- 0 1 0 9/17/2019 3:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORMS R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio KITCHEN 11 ft 0 180 ft' ____ 0 1 0 7 Slab -On -Grade Edge Insulatio JUNIOR M. BED 14 ft 0 198 ft2 -__- 0 1 0 8 Slab -On -Grade Edge Insulatio BATH 1 ft 0 50 ft2 --_- 0 1 0 9 Slab -On -Grade Edge Insulatio POWDER 5 ft 0 35 ft' ---- 0 1 0 10SIab-On-Grade Edge Insulatio NOOK 6 ft 0 42 ft2 ___- 0 1 0 11SIab-On-Grade Edge Insulatio LAUNDRY 17 ft 0 49 ft' ____ 0 1 0 I 12SIab-On-Grade Edge Insulatio ENTRY 5.9 ft 0 103.5 ft' ___ 0 1 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) I 1 Hip Metal 1817 ft' 0 ft' Light N 0.6 No 0.9 No 0 18.4 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC i 1 Full attic Vented 300 1724 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type i 1 Under Attic (Vented) GREAT ROOM 30 Blown 546 ft' 0.1 Wood 2 Under Attic (Vented) MASTER BEDRO 30 Blown 354 ft' 0.1 Wood j 3 Under Attic (Vented) WIC 30 Blown 77 ft' 0.1 Wood I 4 Under Attic (Vented) CLST. 30 Blown 35 ft' 0.1 Wood 5 Under Attic (Vented) M BATH 30 Blown 54 ft' 0.1 Wood 6 Under Attic (Vented) KITCHEN 30 Blown 180 ft' 0.1 Wood 7 Under Attic (Vented) JUNIOR M. BED 3D Blown 198 ft' 0.1 Wood 8 Under Attic (Vented) BATH 30 Blown 50 ft2 0.1 Wood 9 Under Attic (Vented) POWDER 30 Blown 35 ft' 0.1 Wood 10 Under Attic (Vented) NOOK 30 Blown 42 ft' 0.1 Wood I I 11 Under Attic (Vented) LAUNDRY 30 Blown 49 ft' 0.1 Wood 12 Under Attic (Vented) ENTRY 30 Blown 104 ft' 0.1 Wood WALLS / V 0 Adjacent n r To IAr n Type c Cavity Width S pace R-Ualu Er I Height Et A Sheathing Framing Solar - Below u 1 SW=>E Exterior Concrete Block- Ext InGREAT ROO 4.1 26 0 9 —1 10 255.7 ft' 0 0 0.4 0 2 NW=>S Exterior Concrete Block- Ext InGREAT ROO 4.1 21 0 9 10 206.5 ft' 0 0 0.4 0 j 3 NE=>W Exterior Concrete Block - Ext InSNASTER BE 4.1 25 0 8 0 200.0 ft' 0 0 0.4 0 _ 4 SW=>E Exterior Concrete Block - Ext InsMASTER BE 4.1 8 0 8 0 64.0 ft' 0 0 0.4 0 9/17/2019 313 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMIRAARY CHFrKi IST RFPORT WALLS 1 / - Adjacent Ornt To WaP Type Space Cavity Width R-NIPI, cr In Height Fr in area Sheathing Framing Solar Below R-Value Frart'nn Ah nr C mrip-1, 5 NW=>S Exterior Concrete Block - Ext InsMASTER BE 4.1 13 0 8 0 104.0 ft' 0 0 0.4 0 6 Nc=>W Exterior Concrete Block - Ext Insu;M BATH 4.1 9 0 8 0 72.0 ft' 0 0 0.4 0 7 SW=>E Exterior Concrete Block - Ext InsuKITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.4 0 8 NE=>W Exterior Concrete Block - Ext InsW1NIOR M. B 4.1 14 0 8 0 112.0 ft' 0 0 0.4 0 9 SW=>E Exterior Concrete Block- Ext Insu'?OWDER 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 10 SW=>E Exterior Concrete Block - Ext Insul NOOK 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 _11 NE=>W Exterior Concrete Block - Ext InsdIAUNDRY 4.1 3 0 8 0 24.0 ft2 0 0 0.4 0 _ 12 SE=>N Exterior Concrete Block - Ext InsdIAUNDRY 4.1 7 0 8 0 56.0 ft2 0 0 0.4 0 13 SW=>E Exterior Concrete Block - Ext InSdIAUNDRY 4.1 7 0 8 0 56.0 ft2 0 0 0.4 0 14 SE=>N Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 _15 N=>SW Garage Frame - Wood ENTRY 11 35 8 280.0 ft2 0.23 0.4 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>N Insulated ENTRY None .39 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation (_>) than ed to Worst Case / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SW=>E 1 Metal Low-E Double Yes 1.04 0.29 Y 46.4 ft2 1 ft 0 in 1 ft 5 in None None 2 NW=>S 2 Metal Low-E Double Yes 1 0.27 Y 40.0 ft2 10 ft 0 in 1 ft 5 in None None 3 NW=>S 5 Meta! Low-E Double Yes 1.04 0.29 Y 32.4 ft2 1 ft 0 in 1 ft 5 in None None 4 NE=>W 6 Metal Low-E Double Yes 1.04 0.29 Y 6.9 ft2 1 it 0 in 1 ft 5 in None None 5 NE=>W 8 Metal Low-E Double Yes 1.04 0.29 Y 16.2 ft2 1 ft 0 in 1 ft 5 in None None 6 SW=>E 9 Metal Low-E Double Yes 1.04 0.29 Y 6.9 ft2 1 ft 0 in 1 ft 5 in None None 7 SE=>N 12 Metal Low-E Double Yes 1.04 0.29 Y 4.7 ft2 6 ft 6 in 1 ft 5 in None None GARAGE _ # Floor Area Ceiling Area Exposed Wall Perimeter Avg Wall Height Exposed Wall Insulation 1 440 ft2 440 ft2 35 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 i 1 Wholehouse Proposed ACH(50) .000272 1231.2 67.59 127.12 .097 5 9/17/2019 3:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHPrK1 IST R(=PC)PT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM _ # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr 1044 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None I Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF III None None ft= DUCTS / --- Supply --- --- Return --- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 175 ft= Attic 45 ft- Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES I Programable Thermostat: Y Ceiling Fans Cooling [[ j) Jan [[ j� Feb [[ jj Mar Heatin[X] Jan [X] Feb (X] Mar jjr ] A r [ ] APr E Ma rX] Jun [X Jul M Y [ ]Jun [ Jul fX] Au [ ]Au[ [Xj Se ] Sep [ ]Oct [ ]Oct j( j� Nov N Nov [[ ]]Dec [X] Dec Venting[I ]1 Jan lI 11 Feb lIX1l Mar (Xl Apr I May [ 1 Jun I Jul [ 1 Aug [ ] SepIXl Oct [I�XII Nov [I ]1 Dec Thermostat Schedule: HERS 2006 Reference Hours j Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 j Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 9/17/2019 3:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft' 0 ft 0.3 GREAT ROOM Defsult(8 Ibs/sq.ft. ft' ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft' ft 0.3 WIC Default(8 lbs/sqft ft' ft 0.3 CLST. Default(8 Ibs/sq.ft. ft' ft 0.3 M BATH Default(8 lbs/sq.ft. ft' ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft' ft 0.3 JUNIOR M. BED Default(8 lbs/sq.ft. ft' ft 0.3 BATH Defauli(81bs/sq.ft. ft' ft 0.3 POWDER Default(81bs/sq.ft. ft' ft 0.3 NOOK Default(8 lbs/sq.ft. ft' ft 0.3 LAUNDRY Default(8 lbs/sq.ft. ft' ft 0.3 ENTRY 9/17/2019 3:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 20-17 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE MANOR 71 IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE MANOR 71 Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: WYNNE BUILDING CORP. Jurisdiction: U W Design Location: FL, Fort Pierce U I I COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks crjoints in the air barrier shall be sealed Ceiling/attic The air barrier in any dropped ceiling/soffit shall oe aligned with The insulation in an dropped ed ceiling/soffit Y the insulation and any gaps in the air barrier shall he sealed. -shall be aligned with the air barrier. i Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls f The junction of the foundation and sill plate shall ba sealed. I Cavities within corners and headers of frame walls The junction of the top plate and the top or excarior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 (Knee walls shall be sealed. per inch minimum. i Exterior tnermal envelope insulation for framed walls shall be installed in substantial contact and ' continuous alignment with the air barrier. . Winnows skylights { The space between window/doorjambs and framing, and and doors f skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors { I� The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to he in contact with the top side floors) j of sheathing, or continuous insulation installed on I i-ne underside of floor framing and extends from the oottom to the top of all perimeter floor framing mei ilbcrs. ' j Crawl space walls ' Exposed earth in unvented crawl spaces shall be covered with .Where provided instead of Floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be oermanenfly attached to the crawlspace I � Shafts, penetrations Duct shafts, utility penetrations, and flue shafts openin to Y P 9 ' exterior or unconditioned space shall be sealed.. Batts in narrow cavities shall be cut to fit, or narrow I Narrow cavities cavities shall be filled by insulation that on ` 'nsn4aticn readily conforms to the available cavity _ spaces Garage separation I Air sealing shall be provided between the garage and conditioned spaces Recessea lighting , Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building I shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plull and wiring Batt insuaton shall be cut neatly to fit around wiring .rid ol„mbing in exterior walls, or insulation that on ,nstallation readily conforms to available space shall' behind pining and wiring. Show a.%_b The a!, barrier installed at exterior wa Is adjacent to showers and _extend Xtenor walls adjacent to showers and tubs shall on exterior wall tubs shag separate them from the showers and tubs. oe nsuleted Electncaliphone box on The air barrier shall be installed behind electrica. or communication exterior walls boxes or air -sealed boxes shall be installed HVAC register boots HVAC register boots that penetrate building then -,al envelope shall _ be sealed to the sub -floor or drywall. Concealed I When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. II Caulking or other adhesive sealants shall not be used to fill voids betty n hip sorinkl r cover plates and wails or ceilings a. ui auumon, inspection or log wails snarl be In accordance with the provisions of IGO-4U0. 9/17/2019 3:13 PM EnergyGauge® USA 6.0.02 (Rev 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 201'7 1EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX' = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 _ 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. is this a worst case? (yes/no) 5. Yes _ b) Single package SEER c; Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1724 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.030 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.285 14. Heating system: Capacity 34.8 c) Area 7c. 153.4 a) Srlit system heat pump HSPF bi Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor.(weighted average) 8a. NA d) Gas furnace, natural gas AFUE t) Solar Heat Gain Coefficient (SHGC) Sb. NA e) Gas furnace, LPG AFUE f) Other 8.50 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 1 OA2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. ' 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes `Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: THE MANOR 71 y2��Op �� `e��p City/FL Zip: FT. PIERCE. FL �L1 S 9/17/2019 3:13:36 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 wrightsoft' Project Summary Entire House QUICK CALCS_ INr SCANN,Pn For. WYNNE BUILDING CORP_ THE MANOR71--- `I Notes: �? (.O Weather. Fort Pierce, FL, US Job: Date: Apr 05, 2018 ay. Winter Design Conditions Summer Design Conditions Outside db Inside db Design TD 42 OF Outside d_b 70 OF Insidedb 28 OF Design TO Daily range Relative humidity Moisture difference Heating Summary Structure 18275 Btuh Central vent (0 cfrn) 6090 �h n • (none) Humidification Humidification 0 Btuh Piping 0 Btuh Equipment load 24368 Btuh Method Construction quality Fireplaces Area (fib Volume (ft3) Air changeslhour Equiv.AVF (tiro) Infiltration Simplified' Average 0 He COolin 1 �g 1724 14809 14809 0.38 0.20 94 49 Heating Equipment Summary Make Carrier Trade CARRIERAIRCONDITIONING Model 2SHBC536AO030 AHRI ref 3645945 Efficiency Heating input Heating output Temperature rise Actual airflow Airllowfactor Static pressure Space thermostat Capacity balance point= 33 OF Backup: 8.5 HSPF 34600 Btuh @477 27 OF 1160 elm 0.048 dmfth 0.08 in H2O Input=7kN,, Ouiout=22529Btuh,100AFUE Calculations 90 OF 75 OF 15 OF 50 % 61 grAb Sensible Cooling Equipment Load Sizing Structure 15981 Btuh 7860 n Central vent (0 ctin) Bftiuh (none) Blower 0 Btuh Use manufacturers data n Ratelswingg mull! 0.95 FAuipmNsensibIsload 22657 Btiuh Latent Cooling Equipment Load Siting Structure 2462 Btuh 2510 Btu Cenntral vent (0 cfm) BBl uh (none) Equipment latent load, 4975 Btuh Equipment Total Load (Sen+Lat) 27632 Btuh Req. total capacity at 0.70 SHR 2.7 ton meetall -�:- wrlghtsoR- - �!-9 ^ "-4r1r-. RigfFStite6Uriwrml201919.0A1 RSW8101 �ftWAMVAM4E-THEMANOR-71.1724-NONPMACrnp Calc=.MJB FmdDooriams N Cooling Equipment Summary Carrier CARRIERAIR CONDITIONING 25HBC536AO030 FX4DNF037 ref 3645945 !ncy 12.0 EER,15 SEER ble cooling 24360 Btuh t000ling 10440 Btuh pooling 34800 Btuh Iairflow 1160 cfin. Nfactor 0.049 cfmBhih pressure 0.08 in H2O sensible heat ratio 0.83 REVIEWED FOR CODE COMPLIANCE 201&Apr-031 Peg BOCC e1 wrightsoft' Right-J® Worksheet Job: Entire House Date: Apr05,2018 QUICK CALCS, INC. By. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Phom:772-466-6799 FaX772-466.8796 EmaiI:OUICKCALCS@AOL.COM 1 Ftwmn EnbreHouss GREAT ROOM 2EVosedyLd 168.0 It 48.0 it 3 Room height ee it d 9.8 ItheaV=l 4 Rwmdme-ai x 27.0 It 5 Rwmarea 1723.5 F 567.0 It` Ty Con*Ldon U-value Or HTM Area Load number (Sh7hfllz°Fj (BNMFj or perim� (N (BWh) a�penme�hx (Iq (B h) Heat Cad Gross N/P/S Heat Cool Gross NIPS Heat Coal 8 - :13A-0oas • '0.143 ,-400 2.55 SM ' _ 532 •: 2131 1 1355 '. 265 218 876 > 4Ai2om [' .0.770 'rIB .'' 2155 38.90 -' 8 '; ''0 :' 139' '238 .0 '. 0 0 •. ..� ;13AAM . 0.770 ne 2156 36.90 46 0 - 990 ' 1695 •- 46 0 99D -',1695 IRJ�C 134-0as 0.143 m 4.00 2.55 104 _. 79 316 200 0 0 0 0 11 4AS-2em 0.770 se 2156 19.31 4 4 94 84 0 0 0 0 `D :. 11D0 13A-0as- 0.390 0.143 se ev 1092 .-400 11.31 255' 21 21 229 237 0 0 0 0 ' . '' 432 :. 410 :1640 . 1042 -•0 o °- 0 0 ?A5-2om -.'. 0.770 sw 21.56 33.76. 6 - 1 'Y39 '218 '9 0 0 -.0 4AS2cm .0.770 sw .' 21.56. . 35.13 ` - 16 .2 : - 346. .. -563 .. "-0 : .- 0 -:0 '.. - . '%0 w IaA-4= 0.143 my 4.00 255 310 237 950 604 206 165 .'' 661 420 4AS-2om 0.770 nw 21.56 36.90 32 0 682 1167 0 0 0 0 _ 4A5-2omd 0.770 nw 21.56 36.90 41 0 880 1505 41 0 880 1505 R. -.._ 12GOsv ;0.091 '- .255 -128 256 268 657 .331 .. 0'.. O 0=.. ,:;0 C - 16&30md 0.032 - 0.90 _ 1.68 1724 1724 1544 2895 567 587 508 953 F � 127q=�1.. �. 0.989 ° - 27.69 '0.00 - 1724 ` 168 . 4652. 0 . .. 567 • 48'. .-- 1329 ...-• :;0 6 c)AEDelmrsim S71 -35 Envelope lossIgain 15389 12708 5243 5094 12 8) Irdltration 2886 814 949 268 b) -RO %enllafion 0 0 0 0 13 Intffnal gains: O=pants@ 230 2 460 0 0 AMpUanm*t r 2000 0 S&btal oin (!I l3) 18275 15981 6193 5362 Lessedamal load 0 0 0 0 Lesstranslar 0 0 0 0 Redstribu6on 0 0 0 0 14 SLftW 18275 15981 6193 5362 15 Dudloads 33% 49% 6093 7868 33% 49% 2084 2640 Totalmomload 24368 2= 8257 8602 ���(dm) 1160 1160 393 389 rdgttSute®Urivarsa1201919.0.01, RSW8701 _oftWAMVVYNNE.THEMANOR-71.1724-NONIMPACrnp Celc•MJB FrortDoorreres N 2019-Apr-D31350:19 Page 1 I wrightsofr Right -A) Worksheet Job' Entire House pate: Apr O5,2018 QUICK CALCS, INC. By. 317 ST. LUCIE UN., FL PIERCE; FL 34946 PInm:772-066-6799 Fax772-066-6796 Emil: OUICKCALCS@AOL.COM 1- Rcomname MASTER BEDROOM VVIC 51.0 ft O ft 3 R height 8.0 ft heatlmol 8A It heaVbDol 4 Room dimenrions 1.0 x 315.0 It 7.0 x 11.0 ft 5 Roomarea 315.0 IF 77.0IF Ty Construction U-value Or HTM Area Load number (Bulftk � - fth" or perimeter Ql) (Shill) as perim� (fl) (Stilt) Heat Cod Gros N/P/S Heat I Cool Gros N/P/S Heat Cwl 6 13A-0a¢ - 0.143 'ne ; 4.00 255 80 80 320 . 204 0 - 0 0 0 AAS-20m- 0.770,nO. 21M . 36.90 0' - ' 0 `0 - .0 : 0- 0 ,,; 0 ;4AS-20M : 0.770 . ne - .21.58 36.90 ,0 .. 0 0 . 0 . 0 - - 0. VN 13A-oars 0.143 s 4.00 2S5 0 0 0 0 0 0 .0 0 0 11 �G 4AS2om 0.770 s 21.55 19.31 0 0 0 0 0 0 0 - 0 TD 11DO 0.390 s 10.92 11.31 0 0 0 0 0 0 0 0 W IF'� 1.3A 6ca 0.143 sw �, .'4.00 255 224 224 -<W7' '.570 0; 0 ' 0 -.0 4A5-21m 0.770 sN : .21.56 33.76 0 0 0 ' 0 0 0 0 : 0 r--G ;4AS26m .0.770 av .`-21.56 - . 35:13 .. 0 `.. , . '0 - 0" .0 �0 ' 0 '. 0 .�..0 V,V 13A4ars 0.143 my 4.00 255 104 72 290 184 0 0 0 0 4AS-2om 0.770 nw 21.56 36.90 32 0 682 1167 0 0 0 0 II--GG _, 4A5-2omd 0.770 nw 2156 36.90 0 0 0 0 0 0 0 0 P'.:.:. 12COw `- .' 0.091 .=.- ,:255 1128! -: 0 -. 0 -: 0 • 0 <0. -'a - ,. '.0 .,.-.. -0 C 16B30md 0.032 - 0.90 1.68 315 315 282 529 77 77 69 129 F: ` ` 22A-tpl 0.989 " - 27.69 0.00. -_ ". 315 . _ 51 . . 1412 0 . 77 .0 .. 0' : .' -.•.0 6 c)AED a cursion. 358 -1 FJnetopelosalgain 3884 3012 69 128 12 a) Infiltration 823 232 0 0 b) Room1en1latioe '0 0 0 0 13 Internalgains Onvpants@ 230 2 460 0 0 Apptanoslolher 0 0 Subtotal Qines6fo13) 4707 3704 69 128 Lese>smalioad 0 0 0 0 Less 0 0 0 0 Redstributon 0 0 0 0 14 Subt7W 4707 3704 69 128 15 Dudloads 339% 49% 1569 1824 33-A 49% 23 63 Total room load 6276 5528 92 192 Airrequired(dm) 299 259 4 - 9 Calculations approved byACCAto meet all requirements of Manual J Sth Ed. 'Fib" wrigl,tisofe- - 2019-Apr-0313:50:19 �cp Ri-1724-NONIuersd201 CaicO1RSW8101 Page2 ...oftFNAC1WYNNETFIE MANOR-71-1724-NON IMPACrnp CaIc=MJB FrortDoorfacex N wrightsoft- RighWO Worksheet Job: Entire House Date: Apro5,2018 QUICK CALCS, INC. ar 317 ST. LUCIE LM.Fr.. PIERCE, FL 34946 Prnre:772-466E799 FW772-466.8796 Emall:OUICI(CALCS@AOLCOM 1- Room name CLST MSATH Oft 9.0 ft 3 Room height 8.0 it heatbool 80 ft hea9000l 4. Room dimmslom 7.0 x 5.0 it 6.0 x 9.0 It 5 Roomama 35.0 IF 540 fF Ty Consfmdion U-%due Cr HTM Area (M Load Area (fly Load number (0 � (BWtt4t� or perimeter (f) (Syh) a perime5r (fq (B6Lh) Heat Cod Gross NAS Heat Caol Gros NIPS Heat Cool 6 lN �-G 1MA= '' 0143 rid 4.D0 ':: - 265 - 0 ; 0 0 : - 0 0 0 0 ' - 0 4AS2oIn . '0.770 ne 21M .. 36.90 0 .. 0 '. .. '0 0 '..0 -- '0 ,- 0 : 0 0.770 : ne :..21.5s . 3s.00 0 ,. o ., o - . o 0 -. o o - ' --;-0 l�✓ 13A-0aLs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 4A5-2om 0.770 s 21.56 1931 0 0 0 0 0 0 0 0 �D 11DO o.390 as 1092 11.31 0 0 0 0 0 0 0 0 '1aA-0ocs . 0.143 w 400 . -12.55 �o .. 0 0. .0 72 66 262 :.167 4A5-20m 0.770 sv 2155 33:76 0 0 .'. 0 . 0 6 .' - 1 1• 139 218 AA&20m . " 6.770 •sv...°: 21.56 . 35.13 0'-' 0 0 -.. .0 0'' 0::'' 0 =`--0 IwII 13A-4= 0.143 nw 4.00 255 0 0 0 0 0 0 0 - 0 �- 4A5-2cm 0.770 rMr 21M 36.90 0 0 0 0 0 0 0 0 �---G �---G 4A5.2omd 0.770 my 21.56 36.90 0 0 0 0 0 0 0 0 P 12c-ow- -, :0.091 `- 255 '128 '0• -0 0. 0 0- -0 0 _......0 C '•. 16a30md 0.032 - 6.90 1S8 35 35 31 59 54 54 48 91 F. 22q-rp1 0.989' .27.69 0.00 35 0 0 0 .54 .9 .� .249 '.."0 6 c)AED exasslm 0 83 Envelopelossrgam 31 58 1 699 559 12 a) Witation 0 0 145 -41 b) Roomlenfilalion 0 0 0 0 13 Intarnal gains Oovpants@ 230 0 0 0 0 APPBansslofher 0 0 SulADMITMIM6013) 31 58 845 600 Lese#emal load 0 0 0A Lestaruer 0 0 0 Redstrifxtion 0 0 0 14 Subfiml 31 58 84515 Dudloads 33% 49% 10 28 33Yo 49% 282Total room load 42 87 1128Airrequired(dm) 2 4 54 Calculations approved bVACCAto meet all requirements of Manual J 8th Ed. ,ft-H+ vl „�/�gMssore- """""^ RigtPSdteGLWwrsal201919.0.01.RSW8101 201&Apr-D37P 9e3 .aftWACAWtM-E-THEMA ANOR-71-1724-NONIMPACrsW Calc=MFrodDoorfacer. N wrightsoft, Right -A Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN..Fr. PIERCE. FL 34946 Phore:772-466-6799 F=772466-6796 Email: 0U1CKCALCS@AOL.COM Job: Date: Apr 05, 2018 Br. 1 3 4. 5 Rbomnarne R �M 9 Rcom dmensore Rbom aria KITCHEN 11.0ft 8.0 It heaNmol 1.0 x 180.0 it 180.0 ft2 JUNIOR M BED 14.0 a SA ft heay000l 1.0 x 198.0 It 198.0 f8 Ty Consladon number U-wlue Mtuhh4 - F) or HTM (Mhffl Area or palmy Ql) (B�Wh) M w� paimehx (i9 Load (13Wh) Heat Cod Gross NM Heat Cool Gmss WFIS Heat Cool 6 W 13A oz 4AS2orri .., . Wm2cwn 13A-4= 4AS-2om 11DO 13A40js 4AS2om 4A5.2om _ 0.143 .0.770 ; D:770 0.143 0.770 0.390 -0.143 • 0.770 0.770 re rle ne., so se se sN sw sv ;-4A0 2156 - 21.56 4.00 21.56 1092 .'.400 = 2158 .. ':21.56 2.55 --'38.80 36.90 2.55 1931 11.31 � . 255 33.7§ 35.13 F Be 0 0, 0 0 0 ," ,0 - 0 0 BB :- 0 - 0 - 0 0 0 :. 0 ,. 0 - .. 0 352 -.. ' 0 _ -0 0 0 0 • � . 0 . , 0 - - 0 224 .0 : :' 0 0 0 0 0 0 .0 0 a - .0 o 0 0 . 112 0,. - 16 , 0 r'. (I - : 0 - 0 0 0 ` 98 0 - 2.'- 0 0 0 0 364 0 , 3E8-5fl' .. ( 1 1 24 +gl �D �G 4AS-2ornd 0.770 my 2156 36.90 0 0 0 0 0 0 0 0 P ';12C-0sw 0.091 - ,255 428 .:p 0 0. 0 .104 104 285 ,133 C 16B30md 0.032 - 0.90 1.68 i8D 180 161 302 198 19S - 177 333 F 22A-ipl 0.989 .2Z69 0:00 180 11 305. ' 0 198 14 4388 'r,0 112I Room Infiltraloientilafion I I I 178I 01 I I 2 0l 0 13 bgam: lfemal gaOovpantsO 230 0 0 n n Lessel�malload LewtranMa Redsfdbufian 14 SuMotal 15 Ductloads 22911 111 Calculations approved byACCA to meet all requirements of Manual J 8th Ed wrl9htsofc- RghFSdte®Uiversa1201919.0.01.RSW8101 2019-Apr-031350:19 ...oftWAQWYNNE-THEMANOR-71-1724-NONIMPACTnp Ca1c=MJ3 FrortDoorfaces N - Page +wrightsoft° Right-lO Worksheet Job: Entire House Data: Apr O5,2018 QUICK CALCS, INC. By. 317 ST.. LUCIE M Fr. PIERCE, FL34946 Phone: 772-466-6799 Fes772-466.6798 Email: QUICKCALCS@,AOLCOM 1 Raomname BATH POWDER Oft 5.0 It 3 Roornheight 8.0 It heatlalol BA It he atbwl 4. Roomrea ions SO x 10.0 It O x 5.0 ft Zft 5 Room alza 50.0 i8 35.0 ft' Ty Construction U-value Or HTM Area (M Load Am (ft') Load number I (Btihi F) (BWh4Pj or Perim pp (Btuh) or perimeter (t9 (Bdh) Heat Cad Gros NAS Heat Cool Gros NIPS Heat Cool 6 W ltt -0 -- .' 0.143 na .4.00 255, b '. 0 0 .0 40 34 134 ,8.5 • 4A5-2om ' - '4AS2om .0.770 m .'-'21.56 36.90 0:�- 0' -- .. C - 0 . 6—< 0 '-'- 139 238 238 .i - 0.770 t_ne - ,21b6 36.90 o o _ :..0 _ ' 0 : {6 0 9 i'. �j 13A4= 0.143 s 4.00 2S5 0 0 0 0 0 0 ., 0 0 11 4AS2om 0.770 s 21M 19.31 0 0 0 0 0 0 0 0 I--u �—D 1100 0.390 s 1092 11.31 0 0 0 0 0 0 0 0 W W. 13A-0ars _ Q143 sx 400 . 2.65. 0 :. 0 0 0 0 . -_ 0 - 0 ' 4A5-2om '.4AS-2am 0.770 sv .2156 33.76' 0 0 0 ..0 0 0 0 .'-0 .0 0.770: sv .-'..2158. ',. M.13 . 0'; 0 -0 0 `. 0 - 0 - 0 ,',,0 13A-0ars 0.143 nw 4-00 2b5 0 0 0 0 0 0 0 0 I--ti L:SIW 4A5-2om 0.770 r w 21.58 36.90 0 0 0 0 0 0 0 0 4AS2omd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 :P (12C41s.4 0.091 - -.255. '128 40- 40 - 102 . 51 C. 0 - C .: 16B30nM '22Mtpl: 0.632 0.90 1.68 50 50 45 84 35 35 .0' 31 ,0 59 F . - 0989 - - ,27.69 0.00 50 0 0 0 : 35 ' ..5 '138 > ,. "0 6 o)AEC exausion _7 Frnelapelosrgain 147 134 443 380 12 a) Inlitration 0 0 81 23 b) Robmeerifilation 0 0 0 0 13- Intemalgaim Omlpanls@ 230 0 0 0 0 Apprianceshtlier 0 0 Subldal Qines6to13) 147 134 1 524 402 LeseDbmaiload 0 0 0 0 Leshansfer 0 0 0 0 Redislnbution 0 0 0 0 14 15 Sual DuctCload9 147 134 524 4D2 33% 491% 49 66 33% 49% 175 198 Total room load 196 201 699 601 Airrequired (Cn0 9 10 33 29 Calculations approved byACCAto meet all requirements of Manual J 8th Ed WgN-SUIe0llHversa1201919.0A1 RSU08101 2018-AprA313:50:19 A .. ftWAQV4 MC-THEMANOR-71-1724-NON&?Aarnp Cadc=MJ8 Frcrf Doorfece%N Page + wrightsoft Right-M Worksheet Entire House QUICK CALLS, INC. 317 ST. LUCIE UM, Fr. PIERCE, FL 34946 Phow: 772466-6799 Fax 772-086-6796 Email: OUICKCALCSMAOL.COM Job: Date: Apr05,2018 By. 1 Room name NOOK LAUNDRY '^WI 6.0 ft 17.0 R 3 Room height 8.0 R heat/cool 8.0 0 heatf000l 4. Room dimensions 7.0 x 6.0 R 7.0 x 8.0 R 5 Roomarea 420 IF 56D IF Ty Cons1rumon U-value Or HTM Area Load (el Lead number (BNMtt°Fj (BWh48) or pedm� (IQ (8tb) �pedmear (R) (BlW) Heat Cool Gros NIPS Hear Cool Gross N/P/8 Heat Cool 6 W, 931 -0 0.143 ne '.400 2.55 4.8 '. 48 :: .192 : 122 64 64 64 . 2563 6 8 .1 463 4A6-2am `�. '4AFa2om 0.770 ne $156 ',36.90 0"' 0 .0. '. ,0 :... 0-- ., 0.270 " ne 21M , :. '36.90 0 . 0 .0 . 0 0 , o .. 0 ,! 0. �N 13A-0oq 0.143 se 4A0 2.55 0 0 0 0 56 52 207 1 1 31 384 11 �G 4A5-2om 0.770 se 2156 19.31 0 0 0 0 4 4 94 �D 11D0 0.390 5e 1092 11.31 0 0 0 0 0 0 0 0 13AAM 0.143 sw -%400 - 255 0 . - 0- .. 0 ' ' .0 716 16 _ 84 4AS20ni ' 0:770 Ex '2156 ' ` 33.76 0 �. 0: 0 • 0 0 0 0 ,4? ,t%0 - V�V 4A5-2am 134-00s .0.770 0.143 sw 2156 "35.13 ' 0 : ' : '0 . 0 ' 0 0 -,' ',.0 0 ' a0 nw 4.00 2.55 0 0 0 0 0 0 0 0 L�CC 4A5-2om 0.770 nw 2156 36.90 0 0 0 0 0 0 0 0 'P:,. 4A5-2omd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 s12C-0sN. 0.091 •- 255 128 % o a 0 0 0 - . • C 1613MMd 0.032 - 0.90 1.68 42 42 - 38 71 56 56 -0 - 50 so ,0 94 F > 22A.lpl- Q989 '- -.' .27.69 - 0.00 - 42 6 - �166 � � " 0 - .'56 -.56 ✓ . -471 ` -94 6 C)AEDexausion _7 4 EmelopeloWgain 396 191 1142 510 12 a) Infilhalion 97 27 774 77 b) Rocmlerr9ation 0 0 0 0 13 trtenalgains O=pants@ 230 0 0 0 0 AppGanoeJalher 0 0 Subtotaloines(I1o13) 493 219 1417 687 Less&malload 0 0 0 0 Lestransfer 0 0 0 0 Recita ibufion 0 0 0 0 14 Subtrxal 493 219 1417 587 15 Ductloads 33% 49°A 164 108 33% 49-1 472 289 Total room load BS 318 18969 Airrequired(dm) 0 43 Calculationsapproved bVACCAto meetall requirements of Manual J 8th Ed 2019-Apr-031350:19 R1-1724-NONIiMPACT01 Calc=MJB Fruri Page �RM/ACNJVNNE-TH6 MANOR-71-171A-NONIMPACTnp CaIc=MJB FrarlOoarfaces: N I wrightsofC Right-J® Worksheet Entire House QUICK CALLS, INC. 311 ST. LUCIE UN, Fr. PIERCE, FL 34946 Pho,e: 772-4666799Fax772466-6798 Email: OUICKCALCS@AOLCOM Job: Date: Apr05,2018 By. 1 Ropmnanle ENTRY 7.0 It 3 Room height 8.0 ft 4 Roomdimensions 1.0 x 114.5heIttroxl 5 Room area 114.5 IF Ty Construr5on U-value or HTM Area Area Load number (Bhlhflli°F) (BWhIR) a pedm� (f) (B�trh) Heat I Cool Gloss NOS Heat Cool Gros NIP1S Heat Cool 6 -13A-0or-s 0.143 m 4.00 2S5 0 .0 0 - -0 I—G L4A546m _0.770 ne.:.. 21M - 36.90 0 '_ .0 0 '• :0 hr 4AS2om . 0.770 M, 21,56 36.90 . 0 ' 0 0 0 lqJ 13AAm 0.143 ss 4.00 2,55 48 27 108 _- 69 11 F—G 4AS-20M 0.770 se 21.56 1931 0 0 0 0 L--D 11DO 0.390 se 1092 11.31 21 21 229 237 ,'. 13A4= .. 0.143,my :40D ....455 "8 . 8 . 32 20 . 4AS2om . --. 0.770 L,w 2158 33.78 ; 0 - 0 0. 0 ., '4A5-20m , : _ .: 0.770 - sw -"21M '. �35.13 ` 0 ' D .. ` -o .. 0 ... .... .. .. W Il--v- 13A-0ors 0.143 my 4.00 2.55 0 0 0 0 4AS2om 0.770 ma 21.56 36.90 0 0 0 0 !—G 4A5-20md 0.770 ma 21.58 36.90 0 0 0 0 P -. 112C.Osv 0.091 - .2.65 128 114 114 290. - 146 C 16Barnd 0.032 - 0.90 1.68 115 115 103 192 F .- ' 22A-lpl:- - 0.989 • _ . Z7.68 ,. 0.00 - 115 _ 7 - 194 - . -- 0 12 a) Infiltration 113 32 b) Roomtentilation 0 0 13 Intemalgalns 0-11 nts@ 230 C 0 Appranoes/olher 0 SUbtiBl Orr s6to13) 1069 692 Lesodemalload 0 0 Lesstransfer 0 0 Redist ibuton 0 0 14 Subtotal 1069 692 15 Ductloads ��, AMI zu u' Calculations approved bVACCAto meet all requirements of Manual J 8th F� Ad-.0 w���'�.� 2019•Apr-031350:19 �cP RigH-SdtNONlk4PACr01819.c=MJSW8101 Pege7 .AflHVACNJYNNE-TFIE MANOR-71-1724NON INPACru,p CaIc=MJB FrortDoorfaces: N - wrightsoft. Duct System Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE UN, FT. PIERCE, FL34946 Phone: 772-466-6799 Faz772.4666796. Email: OUICKCALCSratAOL.COM For. WYNNE BUILDING CORP. THE MANOR71 NON IMPACT, FT. PIERCE, FL E1Qemal.static pressure Pressure losses Availablestatic pressure Supply / return available pressure Lowestfdction rate Actual airflow Total effective length (rEL) Heating. 0.08 in H2O 0 in H2O 0.08 in H2O 0.040 / 0.040 in H2O 0.051 in/100ft 1160 cfm 156 it Job: Date: Apr 05, 2018 By. Cooling 0.08 in H2O 0 in H2O 0.08 in H2O 0.040 / 0.040 in H2O 0.051 in/100ft 1160 clan Name Design (BWh) Htg (cfin) Clg Minn) Design FR Diam (in) H x W (In) Dud Mail Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH c 201 9 10 0.074 4.0 OxO VIFx 18.4 90.0 sH CLST. c 87 2 4 0.071 4.0 OxO MFx 22.5 90.0 sill ENrRY h 1425 68 - 50 0.108 5.0 Ox0 VIFx 4.0 70.0 -- GREATROOM h 4129 197 195 0.054 8.0 0x0 VIFx 37.3 110.0 st3 GREaTRooMB h 4129 197 195 0.053 8.0 OxO VIFx 39.8 110.0 st3 JUNIORNLBED h 2381 113 111 0.076 7.0 OxO VIFx 24.7 90.0 st1 KncFEN c 3819 63 186 0.070 7.0 Ox0 VIFx 24.2 90.0 st1 LAUNDRY h 1889 90 43 0.078 5.0 OxO VIFx 13:1 90.0' sa MBATH h 1126 54 44 0.067 6.0 Ox0 VIFx 29.6 90.0 st1 MASTERBEDROOM h 3138 149 134 0.054 6.0 OxO VIFx 39.3 110.0 st3 MASTERBEDROOM-A h 3138 149 134 0.051 6.0 Ox0 VIFx 45.9 110.0 st3 NOOK h 657 31 16 0.082 5.0 Ox0 VIFx 7.8 90.0 s12 POWDER h 699 33 29 0.082 5.0 Ox0 VIFx 7.2 90.0 -_ st2 . wic c 192 4 9 0.056 4.0 OxO VIFx 33.8 110.0 st3 Trunk Htg Clg Design Veloc Diam HxW Dud Name. Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 PeakAVF 696 667 0.051 886 12:0 0 x 0 VnlFlx st1 " st1 PeakAVF 938 1022 0.051 956 14.0 0 x 0 VinIFIX st2 PeakAVF 154 88 0.078 350 9.0 0 x 0 VnlFlx wri htsoft' 2019-Apr.031350:19 RI9N-Sute8UiwMI201919A.01 RSU08101 Page ^V�._oRRWACIWYWE-TFEMANOR-71-1724-NONIMPAMW Cedc=MJB I Mrf Doorfa= N Name Grille Size (n) Htg (cim) Clg (cfrn) T& (ft) Design FIR Veloc (ipm) Diam (in)(n) H x W Stud/Jdist Opening (in) .,Duct Matl Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 MFx C +k- wrighrsoR^ RigH-SULCUrimrsa1201919.0A1 RSW8101 ^�+�^...oftWAQWYNNE-THEMANOR-71-1724-NONIMPACrxW Calc=MJB FmitDoorfams: N 2019-Apr-0313:60.19 Paga2