FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE ROYALE IMPACT
Builder Name: WYNNE
SCANNED
Street: WYNNE DEV.
Permit Office: ST. LUCIE COUNTY
��
City, State, Zip: FT`. PIERCE, FL,
Owner: 2-\ ��A ,�],�`
_
Permit Number:
Jurisdiction:
9q
�t. Lucie
l CeComb
,
Design Location: FL, Fort Pierce v
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1688.7 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1448.70 ft'
b. Frame - Wood, Adjacent
R=11.0 240.00 ft'
3. Number of units, if multiple family 1
c. N/A
R= ft.
4. Number of Bedrooms 3
d. N/A
R= ft'
5. Is this a worst case? Yes
10. Ceiling Types (1720.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1720.00 fit'
6. Conditioned floor area above grade (ft') 1720
b. N/A
R= ft'
Conditioned floor area below grade (ft') 0
c. N/A
R= ft'
11. Ducts
R ft'
7. Windows(155.4 sgft.) Description Area
a. Sup: Attic, Rat: Attic, AH: Attic
6 275
a. U-Factor: Sgl, U=1.04 115.42 ft'
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.11 40.00 ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft.
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft a.
Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.316 ft.
Area Weighted Average SHGC: 0.285
14. Hot water systems
8. Floor Types (1720.0 sgft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ft'
b. Conservation features
EF: 0.970
b. N/A R= ft'
None
c. N/A R= ft'
16. Credits
Pstat
Glass/Floor Area: 0.090 Total Proposed Modified Loads: 65.56
PASS
Total Baseline
Loads: 56.16
1 hereby certify that the plans and specifications covered by
Review of the plans and
f%E STa�6
this calculation are in compliance with the Florida Energy
specifications covered by this
D�
a O�
Code.
calculation indicates compliance
�1 „
i,, °j is
with the Florida Energy Code.
y .. a •,,., o• P
"I
PREPA D BY:
Before construction is completed
r
DATE:
this building will be inspected for
compliance with Section 553.908
t
I hereby certify that this building, as designed, is i pliance
Florida Statutes.
with the Florida Energy Code.
COD, {R
OWNERIAGEf1L .
BUILDING OFFICIAL:
DATE: W
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACHA MIED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC
q/15/2019 10:17 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT 5UMMAKY (;NEGKLIST REPL)K 1
PROJECT
Title: WYNNE THE ROYALE IMPA Bedrooms: 3
Address Type:
Street Address
'Building Type: User Conditioned Area: 1720
Lot #
Owner Name: Total Stories: 1
Block/Subdivision:
# of Units: 1 Worst Case: Yes
PlatBook:
• Builder Name: WYNNE Rotate Angle: 135
Street:
WYNNE DEV.
Permit Office: ST. LUCIE COUNTY Cross Ventilation: No
County:
St. Lucie
Jurisdiction: Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1720 13760
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 BEDROOM 343 2744 No
0
1
1 Yes
Yes
Yes
2 WIC 63 504 No
0
1 No
Yes
Yes
3 M.BATH 56 448 No
0
1 Yes
Yes
Yes
4 KITCHEN 172 1376 Yes
0
1 No
Yes
Yes
5 BATH 45 360 No
0
1 Yes
Yes
Yes
6 BEDROOM 2 204 1632 No
0
1
1 Yes
Yes
Yes
7 ENTRY 98 784 No
0
1 Yes
Yes
Yes
8 LAUNDRY 42 336 No
0
1 Yes
Yes
Yes
9 GREAT/DINING 528 4224 No
0
1 Yes
Yes
Yes
10 BEDROOM 3 169 1352 No
1
1
1 Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0
343 ft'
___
0 1
0
2 Slab -On -Grade Edge Insulatio WIC 1 ft 0
63 ft'
___
0 1
0
3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0
56 ft'
___
0 1
0
4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0
172 ft'
0 1
0
5 Slab -On -Grade Edge Insulatio BATH 5 ft 0
45 ft'
___
0 1
0
6 Slab -On -Grade Edge Insulatio BEDROOM 2 42.6 ft 0
204 ft'
_-
0 1
0
7 Slab -On -Grade Edge Insulatio ENTRY 6.3 ft 0
98 ft'
___
0 1
0
9/15/2019 10:17 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
'
8 Slab -On -Grade Edge Insulatio LAUNDRY Eft
0
42 ft2
___
0
1
0
9Slab-On-Grade Edge Insulatio GREAT/DINING 48 ft
0
528 ft2
0
1
0
10SIab-On-Grade Edge Insulatio BEDROOM 3 13 ft
0
169 ft2
___
0
1
0
ROOF
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
V
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Gable or Shed Metal 1813 ft2
286 ft2
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
J
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1720 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) BEDROOM
30
Blown
343 ft2
0.1
Wood
2
Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
3
Under Attic (Vented) M. BATH
30
Blown
56 ft2
0.1
Wood
4
Under Attic (Vented) KITCHEN
30
Blown
172 ft2
0.1
Wood
5
Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6
Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
7
Under Attic (Vented) ENTRY
30
Blown
98 ft2
0.1
Wood
8
Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
9
Under Attic (Vented) GREAT/DINING
30
Blown
528 ft2
0.1
Wood
10
Under Attic (Vented) BEDROOM 3
30
Blown
169 ft2
0.1
Wood
WALLS
Adjacent Cavity Width
Height
Sheathing Framing Solar
Below
Space
1
N=>SE
Exterior Concrete Block - Ext InseEDROOM
4.1 9
0 8
0
72.0 ft2
0
0
0.4
0
2
S=>NW
Exterior Concrete Block - Ext InseEDROOM
4.1 29
0 8
0
232.0 ft2
0
0
0.4
0
3
W=>NE
Exterior Concrete Block - Ext InseEDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.4
0
_ 4
S=>NW
Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.4
0
_ 5
N=>SE
Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.4
0
_ 6
N=>SE
Exterior Concrete Block - Ext InfilEDROOM 2
4.1 14
0 8
0
112.0 ft2
0
0
0.4
0
_ 7
NE=>S
Exterior Concrete Block - Ext InfiffDROOM 2
4.1 2
10 8
0
22.7 ft2
0
0
0.4
0
8
E=>SW
Exterior Concrete Block - Ext InRffDROOM 2
4.1 9
0 8
0
72.0 ft2
0
0
0.4
0
_ 9
SE=>W
Exterior Concrete Block - Ext InfilEDROOM 2
4.1 2
10 8
0
22.7 ft2
0
0
0.4
0
_ 10
S=>NW
Exterior Concrete Block - Ext InfiEDROOM 2
4.1 14
0 8
0
112.0 ft2
0
0
0.4
0
_ 11
NE=>S
Exterior Concrete Block - Ext Insul ENTRY
4.1 1
5 8
0
11.3 ft2
0
0
0.4
0
12
E=>SW
Exterior Concrete Block - Ext Insul ENTRY
4.1 5
0 8
0
40.0 ft2
0
0
0.4
0
9/15/2019 10:17 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing Solar
Belo w
13 S=>NW Exterior Concrete Block - Ext InsdIAUNDRY 4.1 6 0 8
14 N=>SE Exterior Concrete Block - Ext Ins REAT/DINI 4.1 28 0 8
15 W=>NE Exterior Concrete Block - Ext In50REAT/DINI 4.1 20 0 8
_ 16 N=>SE Exterior Concrete Block - Ext InEEDROOM 3 4.1 13 0 8
17 N=>SE Garage Frame - Wood BEDROOM 3 11 30 8
0 48.0 ft2
0 224.0 ft2
0 160.0 ft2
0 104.0 ft2
240.0 ft2
0 0 0.4
0 0 0.4
0 0 0.4
0 0 0.4
0.23 0.4
0
0
0
0
0
DOORS
# Ornt Door Type Space
Storms
U-Value
Ft
Width Height
In Ft In
Area
1 E=>SW Insulated ENTRY
None
.39 3
6 8
20 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
_ / Wall
V # Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Overhang
Area Depth Separation Int Shade
Screening
1 W=>NE 3 Metal Low-E Single Yes
2 S=>NW 4 Metal Low-E Single Yes
3 E=>SW 8 Metal Low-E Single Yes
4 N=>SE 14 Metal Low-E Single Yes
5 W=>NE 15 Metal Low-E Single Yes
6 N=>SE 16 Metal Low-E Single Yes
1.04 0.29 N
1.04 0.29 N
1.04 0.29 N
1.04 0.29 N
1.11 0.27 N
1.04 0.29 N
32.4 ft2 1 It 0 in
6.9 ft2 1 ft 0 in
23.2 ft2 1 ft 0 in
36.8 ft2 1 ft 0 in
40.0 ft2 10 ft 0 in
16.2 ft2 1 ft 0 in
1 ft 5 in Drapes/blinds
1 ft 5 in None
1 It 5 in None
1 ft 5 in None
1 ft 5 in None
1 ft 5 in None
Exterior 5
None
None
None
None
None
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 300 ft2 300 ft2
30 ft
8 ft
11
INFILTRATION
# Scope Method SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000356
1605.3 88.13 165.74 .1233
7
HEATING SYSTEM
# System Type Subtype
Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split
HSPF:8.5
34.8 kStu/hr
1
sys#1
COOLING SYSTEM
# System Type Subtype
Efficiency
Capacity Air Flow SHR Block
Ducts
1 Central Unit/ Split
SEER: 15 34.8 kBtu/hr
cfm 0.85 1
sys#1
9/15/2019 10:17 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
• 1 Electric
None
Garage
0.97
40 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System
Model # Collector Model
# Area Volume
FEF
None None
ft'
DUCTS
/ —Supply—
—Return—
Air
CFM 25
CFM25
HVAC#
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT ON RLF
Heat Cool
1 Attic
6 275 ft'
Attic
65 ft'
Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programablre'Thermostat:
CFans:
]]Y
Heat ng Jan [X] Feb
Mar
Apr[[eiling
Apr
May
[X]
Jun ]Jul
]
4X] A g
[X]
[ ) Sep
[ ] [rX,]
LJ
m
Nov
Nov
Dec
H Dec
Venting I 1 Jan [ 111) Feb
L 1
X Mar
[
Jun 1 Jul
E
I 1 Aug
[ 1 Sep
lxl Occtt
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9 10
11
12
Coaling (WD) AM
78
78
78
78
78 78
78
78
80 so
80
80
PM
80
80
78
78
78 78
78
78
78 78
78
78
Cooling (WEH) AM
78
78
78
78
78 78
78
78
78 78
78
78
PM
78
78
78
78
78 78
78
78
78 78
78
78
Heating (WD) AM
66
66
66
66
66 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
66
66
Heating (WEH) AM
66
66
66
66
66 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft'
0 ft
0.3
BEDROOM
Default(8 lbs/sq.ft.
ft'
ft
0.3
WIC
Default(8 Ibs/sq.ft.
ft'
ft
0.3
M. BATH
Default(8 lbs/sq.ft.
ft'
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft'
ft
0.3
BATH
Default(8 Ibs/sq.ft.
ft'
ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft'
ft
0.3
ENTRY
Default(8 lbs/sq.ft.
ft'
ft
0.3
LAUNDRY
Default(8 lbs/s.ft.
ft'
ft
0.3
GREAT/DINING
9115/2019 10:17 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE ROYALE IMPACT Builder Name: WYNNE
Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
Owner: Jurisdiction:
w
Design Location: FL, Fort Pierce
_
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall -
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks orjoints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
/soffit
The insulation in an dropped ed ceiling/soffit
Y
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind ninino and whina
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
I
between fire qnrinkler cover and wnllq or cellinas
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
-9/15/2019 10:1 S AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index,
the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single -family -or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1720
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
1.058
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.285
14. Heating system: Capacity
34.8
c) Area
7c.
155.4
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
0 Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatReC%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
1061.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
0 Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features. I
Builder Signature: Date:
* c 1 ,C
Address of New Home: WYNNE DEVI�I `V�.E4% �W44Qe () City/FL Zip: FT. PIERCE. FL -`t[ 57
9/15/2019 10:18:06 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
-F�- wrightsoft® Project Summary
Entire House
QUICK CALCS, INC.
SCANNED Job:
BY BY:
S4 Uderninty
For. THE ROYALE
WYNNE D_E1�V., FT. PIERCE, FL
Notes:
Design Information
Weather. Fort Pierce, FL, US
Winter Design Conditions
Outside db
Inside db
Design TD
Summer Design Conditions
42 OF Outside db
70 OF Inside db
28 OF Design TD
Daily range
Relative humidity
Moisture difference
Heating Summary
Structure 19898 Btuh
Ducts 6092 Btuh
Central vent (0 cfm) 0 Btuh
(none)
Humidification 0 Btuh
Pi in
Equipment load 25990 Btuh
Infiltration
Method
Construction quality
Fireplaces
Area (ft2)
Volume ("
Air changeslhour
Equiv. AVF (cfm)
Simplified
Average
0
lie 1pin
Co lln
10
10..20
38
90
47
Heating Equipment Summary
Make Carrier
Trade CARRIER AIR CONDITIONING
Model 25HBC536A'030
AHRI ref 7914585
8.5 HSPF
34600
Btuh @ 470F
27
OF
1160
cfm
0.045
cfm1Btuh
0.50
in H2O
point = 35 OF
Backup:
Input = 7 kW, Output = 23009 Btuh, 100 AFUE
90 OF
75 OF
15 OF
50 %
61 gdlb
Sensible Cooling Equipment Load Sizing
Structure
18607
Btuh
Ducts
9204
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Blower
0
Btuh
Use manufacturer's data
n
Rate/swingg multipplier
Equipmeri
0.95
sensible load
26420
Btuh
Latent Cooling Equipment Load Sizing
Structure
2182
Btuh
Ducts
2516
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Equipment latent load
4697
Btuh
Equipment total load
31117
Btuh
Req. total capacity at 0.70 SHR
3.1
tan
Cooling Equipment Summary
Make Carder
Trade CARRIERAIR CONDITIONING
Cond 25HBC536A•030
Coil . FX4DN(B,F)037
AHRI ref 7914585
Efficiency 12.0 EER, 15 SEER
Sensible cooling
24360
Btuh
Latent cooling
10440
Btuh
Total cooling
34800
Btuh
Actual airflow
1160
cfm
Air flow factor
0.042
cfm/Btuh
Static pressure
0.50
in H2O
Load sensible heat ratio
0.86
Calculations approved byACCA to meet all
wrightsofY Right -Suite® Universal 201717.0.14 RSU08101 �� �� ®g a��p017-Apr-1017:9:
...\Quick CalcslDwumentslWYNNE-ROYALE-REVISED.mp Calc=Wg Front Dwrfaces:f h, j ,,ppsappaa M E Y
BCC
B
OI
t
t�+0000000Otp1`00100 - -
Y1
N'
(Dp
N
00
0005)N^
L
sffi
00 000 Oj0 �VO O O s
O
�
�00
�
a{
� O
N
O O ON m
m
O•
w�i
�VOOOOOOO�OnN00l�N
o
�
N
p•
m
a
cdO O
�E
y
N0000000t�0't�00.C.j ." -
O
N
`o
(7
,VQSj
SN
yNj
m
U
v
.TryTry
��
��ppp� qq
pp��.pp.�AA�pp AA.yy
N�m�N�N01�N OJ��NN�
N
AO
a�
40S
OOOOmj [�Vj
t'O
�Qj
O
�
n
N
10
�O�
W
�0
CCAA p
N�Ot�I tOMN�O� VhVO N� .'
e
a
w�
��
vp)
3
.00 ..
t4 0)
y
r mm yy ((�� gy�pp• Q m a
Lj��C)M�NNNNr Qt�ONnA ..
o
�O ISM N NNMr N 4_N f70
U
NfV m.F"Ill 5N
vY; ua'�No
��
g��Oi `�i•gg�i big $`�i gu��i, v'��+$^�
g
}j
at7N CRUC)'Ov <th O�N.NOI�i
233
LL
�N�VQ��V'C�O�I`.OIMm -
N
��
G 000•�C.00 0•�COCi O•
��
m
u &
0
C
2
Nqq
C
E
pq pp qq��,,
C¢�.dG �6.Ey�
a
E
rgES
Q,
•
�NMVN
t0
0
N
OI
0
l
m
4
wrightsoft Right-J® Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By:
317 ST. LUCIE I.M. FT. PIERCE, FL 34946 Phone: 77246"799 Fax 772466-6796 Emil: QUICKCALCS a@AOL.COM
1
Room narne
WIC
M. BATH
2
ExImed wall
OR
8.0 It
3
Room height
8.0 R heaycod
8.0 ft heaVcod
4
Room dimensions
7.0 x 9.0 It
7.0 x 8.0 ft
5
Room area
63.0 %'
56.0 %'
Ty
Construction
U-value
Or
HTM
Area
Load
Area
number
I
(BtUIJftMF)
(Stull
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
WP/S
Heat
Cool
Gross
WP/S
Heat
Cod
- 6
Aj�t -.-
13A-4=
0.143
n
4.00
2.65
- 0
0
0
0
0
0
0
0
1Aclom
1.270
n
35.55
34.77
0
0
0
0
0
0
0
_
0
4A5-2om
0.770
n
21.56
19.31
0
0
0
0
0
0
0
0
W
13A-4ms
0143
ne
4.00
255
0
0
0
0
0
0
0
0
11
MAccs.
0143
e
- 4.00
-255
0
0
0
0
0
0
0
0
`
'_
S1Aclorn -
-
.1 270
a-,
* .35.56
. 87.29
. 0
- - 0
: 0
'. '.0
0
0
' 0
0
i11D0- .. -
. 0.390.
a
10.92
. . 11:31
. - 0
0..
0
0
_ 0:
0
.
. 6
-0
W
13A4=
0.143
se
4.00
2.55
0
0
0
0
0
0
0
0
yI
13Adocs c*
0.143
s"...
`= 4.00
:255
�. 0
0
.. 0
- 0
'64:_.
.57
. i 228
• '145
`C
1Actom -
.1.270
: s.
.35.55
34.77,
0
.. 0
, 0..
0
7
.' 7
247
.
I ' . ,241'.
by
13A =
0.143
w
4.00
255
0
0
0
0
0
0
-
0
0
1A-clam
1.270
w
35.56
55.25
0
0
0
0
0
0
0
0
t�GC
'
4A5-2an
0.770
w
21.56
45.63
0
0
0
0
0
0
0
0
P_ -412C-05w
. -
0.091
-
2.55
1.28
' 0.
0
- 0
C
0
0
-0
`.0
C
16A30md
0.032
-
0.90
232
63
63
56
146
56
56
50
130
.F' `
22A4pl
0.989
-
27.69
-. 0.00
63
0
0
- .0
. . 66
- 8
: - '222
0
6
c)AEE etxursion
-10
39
Em+elope loss/gain
56
136
7471
477
12
a) Infiltration
0
0
119
34
b) Roomventilation
0
0
0
0
13
hemal gains: Occupants @ 230
0
0
0
0
Applianceslother
0
0
Subtotal (lines 6 to 13)
56
136
866
__ 511
Lesse#emal load
0
0
0
0
less transfer
0
0
0
0
Redistritiutlon
0
0
14
Subtotal
56
136
866
511
15
Duct loads
31%
49%
17
67
31%
49%
265
253
Total room load
74
203
115
764
Air
Air re
3
8
50
32
A -FI*- wrightsofV Right-Sule® Universal 201717.0.14 RSU08101
...1Quick Calcs\Documents\WYNNE-ROYALE-REVISED.mp CaIc=MJ8 Front Doorfaces:
2017-Apr-10 17:29:34
Page 2
wrightsoft2 Right-JO Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST. LUCIE LN, FT. PIERCE, FL 34946 Phone: 77248"799 Fax 772466-6796 Email OUICKCALCS@ AOL.COM
1
Room name
KrrCHPN
BATH
2
=ed wall
0 ft
5.0 ft
3
Roam height
8.0 It heaticool
8.0 ft heat/cool
4
Room dimensions
1.0 x 172.0 It
9.0 x 5.0 It
5
Room area
1720 ft2
45.0 ft2
Ty
Consmrction
U-value
Or
HTM
Ala
Load
Am (ft2)
Load
number
(BtuMftMF)
(Btuhfft2)
or _ perimeter (ft)
(Bluh)
or Perimeter (ft)
(etuh)
Heat
Cool
Gross
WRIS
Heat
Cool
Gmss
WPIS
Heat
Cool
6
13A-4ccs
0.143
n -
4.00
Z55
0
0
0
0
40
40
1_60
102
.1Aciom
1.270
n
35.56
.34.77
0
0
0
0
0
0
:0
0
4A5-2om
0.770
. n
21.56
.19.31
0
0
0
0
0
0
0
0
w
13A-4=
0.143
ne
4.00
2.55
0-
0
0
0
0
0
0
0
11
141
13A4bcs
0.143
a
4.00
Z55
0
0
0
0
0
0
0
0
;tAclom.
1.270
a
35.56
87.29
0
0
0
0
- 0
0
0-
0
11DO
0.390
e-•-
10.92
11:31
.0.
- 0
.. 0
0.
-0
- 0.
0.
0
w
13A4acs
0.143
se
4.00
255
0
0
0
0
0
0
0
__
0
1
"1--f.`
:13A4ocs" - -
0.143:'s'
." 4.00
"255
'
- 0-
:0'
-. 0
.0
0",
0"
0
..'0
14Ac1om,".
1.270
. s
' -35.56
. 34,77
0-'
0
- - 0..
0
0'
.0
.0
. . A
V)/
1�
13A4=
0.143
w
4.00
255
0
0
0
0
0
0
0
0
1Aclom
1.270
w
35.56
55.25
0
0
0
0
0
0
0
0
4A5-2-
0.770
w
21.56
45.63
0
0
0
0
0
0
0
0
P - :. ,.'
12C-0sw ..
0.091
, - `.
" 2.55
:, 128
- 64.
, 64
163
" 82
0
0
. -0
. - 0
C
16A30md
0.032
-
0.90
232
172
172
154
399
45
45
40
104
'F- >
32A-tpl -
0.989
-
- 27.69
0.00
172
- 0
'0
.0
...46
5
.-' :138
Y 0
61
c)AED exuision
-176
-16
Envelope loss/gain
317
3D5
339
190
12
a) InOnration
0
0
74
21
b) Rwnnverdilation
0
0
0
0
13
Internal gains: Occupants @ 23D
0
0
0
0
Appliwoeslother
200D
0
Subtotal (lines 6 to 13)
317
2305
413
211
Less adernal load
0
0
0
0
Lass transfer
0
0
0
0
Redistribution
0
0
14
Subtotal
317
2305
413
2111
15
Duct loads
31%
49%
97
1140
31%
49%
127
104
Total room load
414
3446
140
315
Air required(cfm)
18
144
24
13
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
ACC ' wrigh45oTt' Right -Suite@ Universal 2017 17.0.14 RSU08101 2017-Apr-1017:Page 3age 3
...\Quick Cates\OocumentslWYNNE-ROYALE-REVISED.mp Cato =MJ8 Front Door (aces: N
rn
00000S4o
000H
�p
�ry�
�
000 0 00000o nm
�m X
fp
ODO mON O�OOOOOg�Ip -
e
'E
o m
000 ��oN000000gm� -
O
a
m
Roo�o�00000ao
000$
o�u�
n
N&
'•
�o
�ffi
..
g
goO m''�Om�00000��i
n$
O o
X
_
8m
�
NOONmNOtO'00000$[7 - -
m
a
Cd
��
NOO �IVO.t+I'000OOgg
tVV lNV
O
e
N
yC�: O.
tl
m ISM ��.N tO N'��Iq N10 NO
N�oiNN��NN�Nv�'v�'�No
=aa
8Y3�388 �88�88C8289
ccc to WOO w0333 - - -,
rl
�N�OQ N���N�NA00 OmI
o co�oo on o.=o 000
$c�
7m
Oa
Is
m
^'
S 0.5,
114
d m
O A T
7 � m
O OOOOOOp Of GjV OV�O :' . .. ._ .. '..' !
q0
00
5y
Coll
Nm
..q$�((��{75
R.
m
o
L
3 .dXS a��SS ii33
�
0 0 o n n
g yy
dM
� �
2
Q x
.-,000OOOOOOnONOm
c7 4
a
6
C9
00000 000�N OOOoP!mo
L
RRmro
OJ
Y]
tO
§S
Oo
..
Zo x
�ro
_
000 oo a,0040000.ov,m
o
s
y
e
"�
0 0
m
N
O,OOoo COO�0000�a�
N
�vJ
o
(9
��(O 1AN �C'I�h��NfON ClO
N ai NN n�NN N �No `
3n3
CConoC C0on0
O^
@s6C
om9yNnN
QnQ; mm NmN�
m�
,�
o 000�oo o" o.=o'000
S
_
88a
ll
o
$�«off
N
yI cI�
8
O
- - wrightsoft• RighW@ Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By:
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email QUICKCALCWAOLCOM
1
Room name
BEDROOM 3
2
Fir ad wall
13.0
13.0 It3
Raom height
8.0 It
4
Room dimensions
13.0 x 13.0 It
5
Room area
169.0 ft-
TY
Construction
U-Value
Or
HTM
Area M9
Load
Area
Load
number
(Btuhlftz F)
(Btuwft,)
or perimeter (it)
(Btuh)
or perimeter
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
WP/S
Heat
Cod
6
V[
-r-G1Aa1om
13A4ocs
0.143
n
4.00
2.55
104
88
353
224
1.270
n
35.56
34.77
16
0
565-
553
4A5-2om
0.770
n
21.56
19.31
0
0
0
0
w
13A4ocs
0.143
ne
4.00
2.55
0
0
0
0
11
13A4ocs
0.143
,e
4.00
2.55
0
0
0
0
..
1Aclonn -
1.270;-e
35.56
87.29
0
0
-0
0
,:
41D0'.
- "0.390
..0
10.92
- .11.31
0
0
" 0
. p
...
w
13A4ocs
0.143
se
4.00
255
0
0
0
0
Vy
13A46cs:.,.
_
0.143,.,s.
4.00:
2.55
... .0
.0
- 0
0-
L--G
,1Ac1om-' -
9:270
's
35.56
. 34i7/
- o
o
: 0
o
-
V)!
13A4ocs
0.143
w
4,00
2.55
0
0
0
0
1Aclom
1.270
w
35.56
55.25
0
0
0
0
4A5-2om
0.770
w
21.56
45.63
0
p
0
p
P-'- ''
12G0sw".....
0.091
-
2S5
1.28
.. .0
0
-0..
.0
;..
C
16A30md
0.032
-
0.90
2.32
169
169
151
392
-
:F..::0:989
. -
27.69
0.00
..169'
13
360
..0
.:
.
6
c)AED excursion
-103
Envelope loss/gain
1430
1066
12
a) Iniftradon
193
59
b) Room ventilation
0
0
13
Internal gains: Occupants @ 230
1
230
Appliances/other
0
Subtotal pines 6 to 13)
1623
1351
Less eldemal load
0
0
Less transfer
0
0
Redistribution
0
0
14
Subtotal
1623
1351
15
Duct loads
31%
49%
497
em
Total room load
2120
2019
19
Air required (cfm)
95
84
-rjt wrightsoTt- RlghtSuite® Universal 201717.0.14 RSU08101 2017-Apt-1017:29:34
...\Quick CalcslDoeumentslWYNNE-ROYALS-REVISEO:mp Colo =MJ8 Front Door faces: N
Page 6
-�- Wrightsoft® Duct System Summary
Entire House
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 7724664i799 Fax 772-466-6795 Email: OUICKCALCS@IOLCOM
For. THE ROYALE
WYNNE DEV., FT. PIERCE, FL
E)demal static pressure
Pressure losses
Available static pressure
Supply /; return available pressure
Lowest friction rate
Actual airflow
Total effective length (TEL)
Heating
0.50
in H2O
0
in H2O
0.50
in H2O
0.250 / 0.250
in H2O
0.286
in/100ft
1160
cfm
Job:
Date:
By:
Cooling
0.50
in H2O
0
in H2O
0.60
in H2O
0.250 / 0.250
in H2O
0.286
intIOM
1160
cfm
175 ft
Name
Design
(Btuh)
Htg
(Cfm)
Clg
(Cfm)
Design
FR
Diam
(In)
H x W
(In)
Duct
Mall
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BATH
h 540
24
13
0.351
4.0
Ox0
VIFx
27.3
115.0
st1
BEDROOM
h 3408
152
139
0.286
7.0
0x0
VIFx
40.1
135.0
st2
BEDROOM 2
h 5376
240
215
0.343
7.0
OxO
VIFx
30.8
115.0
st1
BEDROOM
h 2120
95
84
0.371
6.0
OxO
VIFx
19.9
115.0
st1
BEDROOM -A
h 3408
152
139
0.297
7.0
Ox0
VIFx
33.1
135.0
st2
ENTRY
h 1272
57
41
0.485
4.0
Ox0
VIFx
8.1
95.0
GREAT/DINING-A
h 3714
166
163
0.300
7.0
OxO
VIFx
31.7
135.0
st2
GREAT/DINING-B
h 3714
166
163
0.309
7.0
OxO
VIFx
27.1
135.0
st2
KITCHEN
c 3446
18
144
0.376
7.0
OxO
VIFx
18.1
115.0
st1
LAUNDRY
h 820
37
18
0.369
4.0
OxO
VIFx
20.4
115.0
st1
M.BATH
h 1131
50
32
0.366
4.0
0x0
VIFx
21.6
115.0
st1
wic
c 203
3
8
0.309
4.0
0x0
VIFx
26.6
135.0
st2
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(cfm)
(cfm)
FR
(fpm)
(in)
(In)
Material
Trunk
st2
Peak AVF
63g
613
0.286
814
12.0
0 x 0
VinlFlx
st1
st1
Peak AVF
1103
1119
0.286
802
16.0
0 x 0
VinIFIX
•,� wri htsoft 2017-Apr-1017:29:35
9 Ripnts�ne® Universal z9n n.e.1a Rsu9e1o1
�CA... Quick Calcs\DmumentskVMNE-ROYALE-REVISED.mp Cato =MJ8 Front Door faces: N Page 1
Return Branch Detail Table
Name
Grille
Size (in)
Htg
(Cfm)
Clg
(Cfm)
TEL
(ft)
Design ,
FIR
Veloc
(fpm)
Diam
(in)
H x W
(n)
Stud/Joist
Opening (in)
Duct
Matl
Trunk
rb1
Ox0
1160
1160
0
1 0
0
0
Ox 0
1
VIFx
•` wrl9 htsOft' 2017-Apr-1017:29:95
RlghtSuite® Universal 2017 17.0.14 RSU08101 Page 2
�'� ...lOuick Calcs%Datum ntslWYNNE-ROYALE-REVISED.mp Cale = MJ8 Front Door faces: N