HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE ROYALE IMPACT Builder Name: WYNNE SCANNED Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY �� City, State, Zip: FT`. PIERCE, FL, Owner: 2-\ ��A ,�],�` _ Permit Number: Jurisdiction: 9q �t. Lucie l CeComb , Design Location: FL, Fort Pierce v County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1688.7 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1448.70 ft' b. Frame - Wood, Adjacent R=11.0 240.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft. 4. Number of Bedrooms 3 d. N/A R= ft' 5. Is this a worst case? Yes 10. Ceiling Types (1720.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1720.00 fit' 6. Conditioned floor area above grade (ft') 1720 b. N/A R= ft' Conditioned floor area below grade (ft') 0 c. N/A R= ft' 11. Ducts R ft' 7. Windows(155.4 sgft.) Description Area a. Sup: Attic, Rat: Attic, AH: Attic 6 275 a. U-Factor: Sgl, U=1.04 115.42 ft' SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 40.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft. SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.316 ft. Area Weighted Average SHGC: 0.285 14. Hot water systems 8. Floor Types (1720.0 sgft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ft' b. Conservation features EF: 0.970 b. N/A R= ft' None c. N/A R= ft' 16. Credits Pstat Glass/Floor Area: 0.090 Total Proposed Modified Loads: 65.56 PASS Total Baseline Loads: 56.16 1 hereby certify that the plans and specifications covered by Review of the plans and f%E STa�6 this calculation are in compliance with the Florida Energy specifications covered by this D� a O� Code. calculation indicates compliance �1 „ i,, °j is with the Florida Energy Code. y .. a •,,., o• P "I PREPA D BY: Before construction is completed r DATE: this building will be inspected for compliance with Section 553.908 t I hereby certify that this building, as designed, is i pliance Florida Statutes. with the Florida Energy Code. COD, {R OWNERIAGEf1L . BUILDING OFFICIAL: DATE: W DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACHA MIED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC q/15/2019 10:17 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT 5UMMAKY (;NEGKLIST REPL)K 1 PROJECT Title: WYNNE THE ROYALE IMPA Bedrooms: 3 Address Type: Street Address 'Building Type: User Conditioned Area: 1720 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: • Builder Name: WYNNE Rotate Angle: 135 Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1720 13760 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 343 2744 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 172 1376 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 98 784 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 528 4224 No 0 1 Yes Yes Yes 10 BEDROOM 3 169 1352 No 1 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 343 ft' ___ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft' ___ 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft' ___ 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 172 ft' 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft' ___ 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 42.6 ft 0 204 ft' _- 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 6.3 ft 0 98 ft' ___ 0 1 0 9/15/2019 10:17 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet ' 8 Slab -On -Grade Edge Insulatio LAUNDRY Eft 0 42 ft2 ___ 0 1 0 9Slab-On-Grade Edge Insulatio GREAT/DINING 48 ft 0 528 ft2 0 1 0 10SIab-On-Grade Edge Insulatio BEDROOM 3 13 ft 0 169 ft2 ___ 0 1 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1813 ft2 286 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC J Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1720 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 343 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 172 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 98 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 528 ft2 0.1 Wood 10 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 N=>SE Exterior Concrete Block - Ext InseEDROOM 4.1 9 0 8 0 72.0 ft2 0 0 0.4 0 2 S=>NW Exterior Concrete Block - Ext InseEDROOM 4.1 29 0 8 0 232.0 ft2 0 0 0.4 0 3 W=>NE Exterior Concrete Block - Ext InseEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 _ 4 S=>NW Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 _ 5 N=>SE Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 _ 6 N=>SE Exterior Concrete Block - Ext InfilEDROOM 2 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 _ 7 NE=>S Exterior Concrete Block - Ext InfiffDROOM 2 4.1 2 10 8 0 22.7 ft2 0 0 0.4 0 8 E=>SW Exterior Concrete Block - Ext InRffDROOM 2 4.1 9 0 8 0 72.0 ft2 0 0 0.4 0 _ 9 SE=>W Exterior Concrete Block - Ext InfilEDROOM 2 4.1 2 10 8 0 22.7 ft2 0 0 0.4 0 _ 10 S=>NW Exterior Concrete Block - Ext InfiEDROOM 2 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 _ 11 NE=>S Exterior Concrete Block - Ext Insul ENTRY 4.1 1 5 8 0 11.3 ft2 0 0 0.4 0 12 E=>SW Exterior Concrete Block - Ext Insul ENTRY 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 9/15/2019 10:17 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w 13 S=>NW Exterior Concrete Block - Ext InsdIAUNDRY 4.1 6 0 8 14 N=>SE Exterior Concrete Block - Ext Ins REAT/DINI 4.1 28 0 8 15 W=>NE Exterior Concrete Block - Ext In50REAT/DINI 4.1 20 0 8 _ 16 N=>SE Exterior Concrete Block - Ext InEEDROOM 3 4.1 13 0 8 17 N=>SE Garage Frame - Wood BEDROOM 3 11 30 8 0 48.0 ft2 0 224.0 ft2 0 160.0 ft2 0 104.0 ft2 240.0 ft2 0 0 0.4 0 0 0.4 0 0 0.4 0 0 0.4 0.23 0.4 0 0 0 0 0 DOORS # Ornt Door Type Space Storms U-Value Ft Width Height In Ft In Area 1 E=>SW Insulated ENTRY None .39 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. _ / Wall V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation Int Shade Screening 1 W=>NE 3 Metal Low-E Single Yes 2 S=>NW 4 Metal Low-E Single Yes 3 E=>SW 8 Metal Low-E Single Yes 4 N=>SE 14 Metal Low-E Single Yes 5 W=>NE 15 Metal Low-E Single Yes 6 N=>SE 16 Metal Low-E Single Yes 1.04 0.29 N 1.04 0.29 N 1.04 0.29 N 1.04 0.29 N 1.11 0.27 N 1.04 0.29 N 32.4 ft2 1 It 0 in 6.9 ft2 1 ft 0 in 23.2 ft2 1 ft 0 in 36.8 ft2 1 ft 0 in 40.0 ft2 10 ft 0 in 16.2 ft2 1 ft 0 in 1 ft 5 in Drapes/blinds 1 ft 5 in None 1 It 5 in None 1 ft 5 in None 1 ft 5 in None 1 ft 5 in None Exterior 5 None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 300 ft2 300 ft2 30 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1605.3 88.13 165.74 .1233 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kStu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 9/15/2019 10:17 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation • 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 275 ft' Attic 65 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablre'Thermostat: CFans: ]]Y Heat ng Jan [X] Feb Mar Apr[[eiling Apr May [X] Jun ]Jul ] 4X] A g [X] [ ) Sep [ ] [rX,] LJ m Nov Nov Dec H Dec Venting I 1 Jan [ 111) Feb L 1 X Mar [ Jun 1 Jul E I 1 Aug [ 1 Sep lxl Occtt Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Coaling (WD) AM 78 78 78 78 78 78 78 78 80 so 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft' 0 ft 0.3 BEDROOM Default(8 lbs/sq.ft. ft' ft 0.3 WIC Default(8 Ibs/sq.ft. ft' ft 0.3 M. BATH Default(8 lbs/sq.ft. ft' ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft' ft 0.3 BATH Default(8 Ibs/sq.ft. ft' ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' ft 0.3 ENTRY Default(8 lbs/sq.ft. ft' ft 0.3 LAUNDRY Default(8 lbs/s.ft. ft' ft 0.3 GREAT/DINING 9115/2019 10:17 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE ROYALE IMPACT Builder Name: WYNNE Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: Jurisdiction: w Design Location: FL, Fort Pierce _ COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall - requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks orjoints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with /soffit The insulation in an dropped ed ceiling/soffit Y the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind ninino and whina Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids I between fire qnrinkler cover and wnllq or cellinas a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. -9/15/2019 10:1 S AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single -family -or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1720 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.058 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.285 14. Heating system: Capacity 34.8 c) Area 7c. 155.4 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE 0 Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatReC% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1061. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit 0 Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. I Builder Signature: Date: * c 1 ,C Address of New Home: WYNNE DEVI�I `V�.E4% �W44Qe () City/FL Zip: FT. PIERCE. FL -`t[ 57 9/15/2019 10:18:06 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 -F�- wrightsoft® Project Summary Entire House QUICK CALCS, INC. SCANNED Job: BY BY: S4 Uderninty For. THE ROYALE WYNNE D_E1�V., FT. PIERCE, FL Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TD Summer Design Conditions 42 OF Outside db 70 OF Inside db 28 OF Design TD Daily range Relative humidity Moisture difference Heating Summary Structure 19898 Btuh Ducts 6092 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Pi in Equipment load 25990 Btuh Infiltration Method Construction quality Fireplaces Area (ft2) Volume (" Air changeslhour Equiv. AVF (cfm) Simplified Average 0 lie 1pin Co lln 10 10..20 38 90 47 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A'030 AHRI ref 7914585 8.5 HSPF 34600 Btuh @ 470F 27 OF 1160 cfm 0.045 cfm1Btuh 0.50 in H2O point = 35 OF Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE 90 OF 75 OF 15 OF 50 % 61 gdlb Sensible Cooling Equipment Load Sizing Structure 18607 Btuh Ducts 9204 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swingg multipplier Equipmeri 0.95 sensible load 26420 Btuh Latent Cooling Equipment Load Sizing Structure 2182 Btuh Ducts 2516 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 4697 Btuh Equipment total load 31117 Btuh Req. total capacity at 0.70 SHR 3.1 tan Cooling Equipment Summary Make Carder Trade CARRIERAIR CONDITIONING Cond 25HBC536A•030 Coil . FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual airflow 1160 cfm Air flow factor 0.042 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.86 Calculations approved byACCA to meet all wrightsofY Right -Suite® Universal 201717.0.14 RSU08101 �� �� ®g a��p017-Apr-1017:9: ...\Quick CalcslDwumentslWYNNE-ROYALE-REVISED.mp Calc=Wg Front Dwrfaces:f h, j ,,ppsappaa M E Y BCC B OI t t�+0000000Otp1`00100 - - Y1 N' (Dp N 00 0005)N^ L sffi 00 000 Oj0 �VO O O s O � �00 � a{ � O N O O ON m m O• w�i �VOOOOOOO�OnN00l�N o � N p• m a cdO O �E y N0000000t�0't�00.C.j ." - O N `o (7 ,VQSj SN yNj m U v .TryTry �� ��ppp� qq pp��.pp.�AA�pp AA.yy N�m�N�N01�N OJ��NN� N AO a� 40S OOOOmj [�Vj t'O �Qj O � n N 10 �O� W �0 CCAA p N�Ot�I tOMN�O� VhVO N� .' e a w� �� vp) 3 .00 .. t4 0) y r mm yy ((�� gy�pp• Q m a Lj��C)M�NNNNr Qt�ONnA .. o �O ISM N NNMr N 4_N f70 U NfV m.F"Ill 5N vY; ua'�No �� g��Oi `�i•gg�i big $`�i gu��i, v'��+$^� g }j at7N CRUC)'Ov <th O�N.NOI�i 233 LL �N�VQ��V'C�O�I`.OIMm - N �� G 000•�C.00 0•�COCi O• �� m u & 0 C 2 Nqq C E pq pp qq��,, C¢�.dG �6.Ey� a E rgES Q, • �NMVN t0 0 N OI 0 l m 4 wrightsoft Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE I.M. FT. PIERCE, FL 34946 Phone: 77246"799 Fax 772466-6796 Emil: QUICKCALCS a@AOL.COM 1 Room narne WIC M. BATH 2 ExImed wall OR 8.0 It 3 Room height 8.0 R heaycod 8.0 ft heaVcod 4 Room dimensions 7.0 x 9.0 It 7.0 x 8.0 ft 5 Room area 63.0 %' 56.0 %' Ty Construction U-value Or HTM Area Load Area number I (BtUIJftMF) (Stull or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cod - 6 Aj�t -.- 13A-4= 0.143 n 4.00 2.65 - 0 0 0 0 0 0 0 0 1Aclom 1.270 n 35.55 34.77 0 0 0 0 0 0 0 _ 0 4A5-2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0 W 13A-4ms 0143 ne 4.00 255 0 0 0 0 0 0 0 0 11 MAccs. 0143 e - 4.00 -255 0 0 0 0 0 0 0 0 ` '_ S1Aclorn - - .1 270 a-, * .35.56 . 87.29 . 0 - - 0 : 0 '. '.0 0 0 ' 0 0 i11D0- .. - . 0.390. a 10.92 . . 11:31 . - 0 0.. 0 0 _ 0: 0 . . 6 -0 W 13A4= 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 yI 13Adocs c* 0.143 s"... `= 4.00 :255 �. 0 0 .. 0 - 0 '64:_. .57 . i 228 • '145 `C 1Actom - .1.270 : s. .35.55 34.77, 0 .. 0 , 0.. 0 7 .' 7 247 . I ' . ,241'. by 13A = 0.143 w 4.00 255 0 0 0 0 0 0 - 0 0 1A-clam 1.270 w 35.56 55.25 0 0 0 0 0 0 0 0 t�GC ' 4A5-2an 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 P_ -412C-05w . - 0.091 - 2.55 1.28 ' 0. 0 - 0 C 0 0 -0 `.0 C 16A30md 0.032 - 0.90 232 63 63 56 146 56 56 50 130 .F' ` 22A4pl 0.989 - 27.69 -. 0.00 63 0 0 - .0 . . 66 - 8 : - '222 0 6 c)AEE etxursion -10 39 Em+elope loss/gain 56 136 7471 477 12 a) Infiltration 0 0 119 34 b) Roomventilation 0 0 0 0 13 hemal gains: Occupants @ 230 0 0 0 0 Applianceslother 0 0 Subtotal (lines 6 to 13) 56 136 866 __ 511 Lesse#emal load 0 0 0 0 less transfer 0 0 0 0 Redistritiutlon 0 0 14 Subtotal 56 136 866 511 15 Duct loads 31% 49% 17 67 31% 49% 265 253 Total room load 74 203 115 764 Air Air re 3 8 50 32 A -FI*- wrightsofV Right-Sule® Universal 201717.0.14 RSU08101 ...1Quick Calcs\Documents\WYNNE-ROYALE-REVISED.mp CaIc=MJ8 Front Doorfaces: 2017-Apr-10 17:29:34 Page 2 wrightsoft2 Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN, FT. PIERCE, FL 34946 Phone: 77248"799 Fax 772466-6796 Email OUICKCALCS@ AOL.COM 1 Room name KrrCHPN BATH 2 =ed wall 0 ft 5.0 ft 3 Roam height 8.0 It heaticool 8.0 ft heat/cool 4 Room dimensions 1.0 x 172.0 It 9.0 x 5.0 It 5 Room area 1720 ft2 45.0 ft2 Ty Consmrction U-value Or HTM Ala Load Am (ft2) Load number (BtuMftMF) (Btuhfft2) or _ perimeter (ft) (Bluh) or Perimeter (ft) (etuh) Heat Cool Gross WRIS Heat Cool Gmss WPIS Heat Cool 6 13A-4ccs 0.143 n - 4.00 Z55 0 0 0 0 40 40 1_60 102 .1Aciom 1.270 n 35.56 .34.77 0 0 0 0 0 0 :0 0 4A5-2om 0.770 . n 21.56 .19.31 0 0 0 0 0 0 0 0 w 13A-4= 0.143 ne 4.00 2.55 0- 0 0 0 0 0 0 0 11 141 13A4bcs 0.143 a 4.00 Z55 0 0 0 0 0 0 0 0 ;tAclom. 1.270 a 35.56 87.29 0 0 0 0 - 0 0 0- 0 11DO 0.390 e-•- 10.92 11:31 .0. - 0 .. 0 0. -0 - 0. 0. 0 w 13A4acs 0.143 se 4.00 255 0 0 0 0 0 0 0 __ 0 1 "1--f.` :13A4ocs" - - 0.143:'s' ." 4.00 "255 ' - 0- :0' -. 0 .0 0", 0" 0 ..'0 14Ac1om,". 1.270 . s ' -35.56 . 34,77 0-' 0 - - 0.. 0 0' .0 .0 . . A V)/ 1� 13A4= 0.143 w 4.00 255 0 0 0 0 0 0 0 0 1Aclom 1.270 w 35.56 55.25 0 0 0 0 0 0 0 0 4A5-2- 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 P - :. ,.' 12C-0sw .. 0.091 , - `. " 2.55 :, 128 - 64. , 64 163 " 82 0 0 . -0 . - 0 C 16A30md 0.032 - 0.90 232 172 172 154 399 45 45 40 104 'F- > 32A-tpl - 0.989 - - 27.69 0.00 172 - 0 '0 .0 ...46 5 .-' :138 Y 0 61 c)AED exuision -176 -16 Envelope loss/gain 317 3D5 339 190 12 a) InOnration 0 0 74 21 b) Rwnnverdilation 0 0 0 0 13 Internal gains: Occupants @ 23D 0 0 0 0 Appliwoeslother 200D 0 Subtotal (lines 6 to 13) 317 2305 413 211 Less adernal load 0 0 0 0 Lass transfer 0 0 0 0 Redistribution 0 0 14 Subtotal 317 2305 413 2111 15 Duct loads 31% 49% 97 1140 31% 49% 127 104 Total room load 414 3446 140 315 Air required(cfm) 18 144 24 13 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ACC ' wrigh45oTt' Right -Suite@ Universal 2017 17.0.14 RSU08101 2017-Apr-1017:Page 3age 3 ...\Quick Cates\OocumentslWYNNE-ROYALE-REVISED.mp Cato =MJ8 Front Door (aces: N rn 00000S4o 000H �p �ry� � 000 0 00000o nm �m X fp ODO mON O�OOOOOg�Ip - e 'E o m 000 ��oN000000gm� - O a m Roo�o�00000ao 000$ o�u� n N& '• �o �ffi .. g goO m''�Om�00000��i n$ O o X _ 8m � NOONmNOtO'00000$[7 - - m a Cd �� NOO �IVO.t+I'000OOgg tVV lNV O e N yC�: O. tl m ISM ��.N tO N'��Iq N10 NO N�oiNN��NN�Nv�'v�'�No =aa 8Y3�388 �88�88C8289 ccc to WOO w0333 - - -, rl �N�OQ N���N�NA00 OmI o co�oo on o.=o 000 $c� 7m Oa Is m ^' S 0.5, 114 d m O A T 7 � m O OOOOOOp Of GjV OV�O :' . .. ._ .. '..' ! q0 00 5y Coll Nm ..q$�((��{75 R. m o L 3 .dXS a��SS ii33 � 0 0 o n n g yy dM � � 2 Q x .-,000OOOOOOnONOm c7 4 a 6 C9 00000 000�N OOOoP!mo L RRmro OJ Y] tO §S Oo .. Zo x �ro _ 000 oo a,0040000.ov,m o s y e "� 0 0 m N O,OOoo COO�0000�a� N �vJ o (9 ��(O 1AN �C'I�h��NfON ClO N ai NN n�NN N �No ` 3n3 CConoC C0on0 O^ @s6C om9yNnN QnQ; mm NmN� m� ,� o 000�oo o" o.=o'000 S _ 88a ll o $�«off N yI cI� 8 O - - wrightsoft• RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email QUICKCALCWAOLCOM 1 Room name BEDROOM 3 2 Fir ad wall 13.0 13.0 It3 Raom height 8.0 It 4 Room dimensions 13.0 x 13.0 It 5 Room area 169.0 ft- TY Construction U-Value Or HTM Area M9 Load Area Load number (Btuhlftz F) (Btuwft,) or perimeter (it) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cod 6 V[ -r-G1Aa1om 13A4ocs 0.143 n 4.00 2.55 104 88 353 224 1.270 n 35.56 34.77 16 0 565- 553 4A5-2om 0.770 n 21.56 19.31 0 0 0 0 w 13A4ocs 0.143 ne 4.00 2.55 0 0 0 0 11 13A4ocs 0.143 ,e 4.00 2.55 0 0 0 0 .. 1Aclonn - 1.270;-e 35.56 87.29 0 0 -0 0 ,: 41D0'. - "0.390 ..0 10.92 - .11.31 0 0 " 0 . p ... w 13A4ocs 0.143 se 4.00 255 0 0 0 0 Vy 13A46cs:.,. _ 0.143,.,s. 4.00: 2.55 ... .0 .0 - 0 0- L--G ,1Ac1om-' - 9:270 's 35.56 . 34i7/ - o o : 0 o - V)! 13A4ocs 0.143 w 4,00 2.55 0 0 0 0 1Aclom 1.270 w 35.56 55.25 0 0 0 0 4A5-2om 0.770 w 21.56 45.63 0 p 0 p P-'- '' 12G0sw"..... 0.091 - 2S5 1.28 .. .0 0 -0.. .0 ;.. C 16A30md 0.032 - 0.90 2.32 169 169 151 392 - :F..::0:989 . - 27.69 0.00 ..169' 13 360 ..0 .: . 6 c)AED excursion -103 Envelope loss/gain 1430 1066 12 a) Iniftradon 193 59 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 1 230 Appliances/other 0 Subtotal pines 6 to 13) 1623 1351 Less eldemal load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 1623 1351 15 Duct loads 31% 49% 497 em Total room load 2120 2019 19 Air required (cfm) 95 84 -rjt wrightsoTt- RlghtSuite® Universal 201717.0.14 RSU08101 2017-Apt-1017:29:34 ...\Quick CalcslDoeumentslWYNNE-ROYALS-REVISEO:mp Colo =MJ8 Front Door faces: N Page 6 -�- Wrightsoft® Duct System Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 7724664i799 Fax 772-466-6795 Email: OUICKCALCS@IOLCOM For. THE ROYALE WYNNE DEV., FT. PIERCE, FL E)demal static pressure Pressure losses Available static pressure Supply /; return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.286 in/100ft 1160 cfm Job: Date: By: Cooling 0.50 in H2O 0 in H2O 0.60 in H2O 0.250 / 0.250 in H2O 0.286 intIOM 1160 cfm 175 ft Name Design (Btuh) Htg (Cfm) Clg (Cfm) Design FR Diam (In) H x W (In) Duct Mall Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 540 24 13 0.351 4.0 Ox0 VIFx 27.3 115.0 st1 BEDROOM h 3408 152 139 0.286 7.0 0x0 VIFx 40.1 135.0 st2 BEDROOM 2 h 5376 240 215 0.343 7.0 OxO VIFx 30.8 115.0 st1 BEDROOM h 2120 95 84 0.371 6.0 OxO VIFx 19.9 115.0 st1 BEDROOM -A h 3408 152 139 0.297 7.0 Ox0 VIFx 33.1 135.0 st2 ENTRY h 1272 57 41 0.485 4.0 Ox0 VIFx 8.1 95.0 GREAT/DINING-A h 3714 166 163 0.300 7.0 OxO VIFx 31.7 135.0 st2 GREAT/DINING-B h 3714 166 163 0.309 7.0 OxO VIFx 27.1 135.0 st2 KITCHEN c 3446 18 144 0.376 7.0 OxO VIFx 18.1 115.0 st1 LAUNDRY h 820 37 18 0.369 4.0 OxO VIFx 20.4 115.0 st1 M.BATH h 1131 50 32 0.366 4.0 0x0 VIFx 21.6 115.0 st1 wic c 203 3 8 0.309 4.0 0x0 VIFx 26.6 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (In) Material Trunk st2 Peak AVF 63g 613 0.286 814 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1103 1119 0.286 802 16.0 0 x 0 VinIFIX •,� wri htsoft 2017-Apr-1017:29:35 9 Ripnts�ne® Universal z9n n.e.1a Rsu9e1o1 �CA... Quick Calcs\DmumentskVMNE-ROYALE-REVISED.mp Cato =MJ8 Front Door faces: N Page 1 Return Branch Detail Table Name Grille Size (in) Htg (Cfm) Clg (Cfm) TEL (ft) Design , FIR Veloc (fpm) Diam (in) H x W (n) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 1160 1160 0 1 0 0 0 Ox 0 1 VIFx •` wrl9 htsOft' 2017-Apr-1017:29:95 RlghtSuite® Universal 2017 17.0.14 RSU08101 Page 2 �'� ...lOuick Calcs%Datum ntslWYNNE-ROYALE-REVISED.mp Cale = MJ8 Front Door faces: N