HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Na : WYNNE THE STERLING IMPACT
Builder Name: WYNNE DEVELOPMENT
Street: THE STERLING
Permit Office: ST. LUCIE COUNTY
SCANN��
City, State, Zip: FT. PIE CR E , EL , \ `
Owner: PK
Permit Number:
B}I
, � �J
Design Location: FL, Fort Pierce
Jurisdiction:
2)
County: St. Lucie (Florida Climate Zone
1. New construction or existing - - -New (From Plans)
9.. Wall Types (1442.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1250.00 ft'
b. Frame - Wood, Adjacent
R=11.0 192.00 ft'
3. Number of units, if multiple family 1
c. NIA
R= ft'
4. Number of Bedrooms 2
d. NIA
R= ft'
5. Is this a worst case? Yes
10. Ceiling Types (1474.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1474.00 ft'
6. Conditioned floor area above grade (W) 1474
b. N/A
R= ft'
Conditioned floor area below grade (ft') 0
c. N/A
R= ft'
11. Ducts
R ft'
7. Windows(141.3 sgft.) Description Area
a. Sup: Attic, Rat: Attic, AH: Attic
6 275
a. U-Factor: Sgi, U=1.04 101.25 ft'
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.11 40.00 ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft'
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. N/A ft'
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.284
14. Hot water systems
8. Floor Types (1473.5 sgft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft'
b. Conservation features
EF: 0.970
b. N/A R= ft'
None
c. N/A R= ft'
15. Credits
Patel
Glass/Floor Area: 0.096 Total Proposed Modified Loads: 47.03
PASS
Total Baseline
Loads: 48.47
1 hereby certify that the plans and specifications covered by
Review of the plans and
S7gl�
this calculation are in compliance with the Florida Energy
specifications covered by this
OF1JJE
y „ _ O�
Code.
calculation indicates compliance
;
° o,
with the Florida Energy Code.
r+ mu••.. D
PREPAI39D B
Before construction is completed
ra
DATE:
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
lt, yC
with the Florida Energy Cod
COD we -
OWNER/ N
BUILDING OFFICIAL:
DATE: L44 7
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (11402.4.1.2).
ABA
f�COI�Ji� ANCE
'T. LUCIE COUNTY
9/17/2019 9:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliarit$'eff eC Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE STERLING IMP Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1474
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units: , 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180
Street:
THE STERLING
Permit Offce: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1474 11792
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 BEDROOM
329 2632 No
0
1
1 Yes
Yes
Yes
2 WIC
63 504 No
0
1 No
Yes
Yes
3 M.BATH
56 448 No
0
1 Yes
Yes
Yes
4 KITCHEN
192 1536 Yes
0
1 No
Yes
Yes
5 BATH
45 360 No
0
1 Yes
Yes
Yes
6 BEDROOM 2
204 1632 No
0
1
1 Yes
Yes
Yes
7 ENTRY
55 440 No
0
1 Yes
Yes
Yes
8 LAUNDRY
42 336 No
0
1 Yes
Yes
Yes
9 GREAT/DINING
488 3904 No
0
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BEDROOM 52 ft 0
329 ft'
0 1
0
2SIab-On-Grade Edge Insulatio
WIC t ft 0
63 ft2
___
0 1
0
3 Slab -On -Grade Edge Insulatio
M. BATH 8 ft 0
56 ft'
___
0 1
0
4SIab-On-Grade Edge Insulatio
KITCHEN 1 ft 0
192 ft'
—
0 1
0
5 Slab -On -Grade Edge Insulatio
BATH 5 ft 0
45 ft'
0 1
0
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 32.2 It 0
203.5 ft'
-_
0 1
0
7 Slab -On -Grade Edge Insulatio
ENTRY 7 ft 0
55 ft'
____
0 1
0
9/17/2019 9:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY Eft
0
42 ft'
___
0
1
0
9 Slab -On -Grade Edge insulatio GREAT/DINING 46 ft
0
488 ft'
--
0
1
0
ROOF
/ Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
V # Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Gable or Shed Metal 1553 fir
246 8'
Light
N
- 0.6-
No 0,9
_
No 0
18.4
ATTIC
/
V # Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
150
1474 ft'
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Vented) BEDROOM
30
Blown
329 ft'
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ft'
0.1
Wood
3 Under Attic (Vented) M. BATH
30
Blown
56 ft'
0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft'
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45 ft'
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ft'
0.1
Wood
7 Under Attic (Vented) ENTRY
30
Blown
55 ft'
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft'
0.1
Wood
9 Under Attic (Vented) GREAT/DINING
30
Blown
488 ft'
0.1
Wood
WALLS
Adjacent Cavity Width
Height
Sheathing Framing Solar
Belo
Space
w
1 NE=>SW Exterior Concrete Block - Ext Ins®EDROOM
4.1 10
0 8
0
80.0 ft'
0
0
0.4
0
2 SW=>NE Exterior Concrete Block - Ext Ins®EDROOM
4.1 28
0 8
0
224.0 ft'
0
0
0.4
0
3 NW=>SE Exterior Concrete Block - Ext Ins®EDROOM
4.1 14
0 8
0
112.0 ft'
0
0
0.4
0
4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 f12
0
0
0.4
0
5 NE=>SW Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft'
0
0
0.4
0
6 NE=>SW Exterior Concrete Block - Ext InfiffDROOM 2
4.1 16
0 8
0
128.0 ft'
0
0
0.4
0
7 SE=>NW Exterior Concrete Block - Ext InfiffDROOM 2
4.1 10
0 8
0
80.0 ft'
0
0
0.4
0
8 S=>N Exterior Concrete Block - Ext IndIffDROOM 2
4.1 4
3 8
0
34.0 ft'
0
0
0.4
0
9 SW=>NE Exterior Concrete Block - Ext IndI EDROOM 2
4.1 2
0 8
0
16.0 ft'
0
0
0.4
0
10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY
4.1 6
0 8
0
48.0 ft'
0
0
0.4
0
11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY
4.1 1
0 8
0
8.0 ft'
0
0
0.4
0
12 SW=>NE Exterior Concrete Block - Ext InsdIAUNDRY
4.1 6
0 8
0
48.0 ft'
0
0
0.4
0
13 NE=>SW Exterior Concrete Block - Ext Ins8REAT/DINI
4.1 26
0 8
0
208.0 fN
0
0
0.4
0
14 NW=>SE Exterior Concrete Block - Ext Ins REAT/DINI
4.1 20
0 8
0
160.0 ft'
0
0
0.4
0
15 N=>S Garage Frame - Wood KITCHEN
11 24
8
192.0 ft'
0.23
0.4
0
9/17/2019 9:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
DOORS
# Omt
Door Type
Space
Storms U-Value Width
Ft In
Height
Ft In
Area
1 SE=>NW
Insulated
ENTRY
None .39 3 1
6 8
20.6 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
/ Wall
V # Ornt ID Frame
Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
1 NW=>SE 3 Metal
_2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW13 Metal
5 NW=>SE14 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
1.04 0.29 N 32.9 ft2 1 ft 0 in 1 ft 5 in
1.04 0.29 N 6.9 ft2 1 ft 0 in 1 It 5 in
1.04 0.29 N 24.0 ft2 6 ft 0 in 1 ft 5 in
1.04 0.29 N 37.5 ft2 1 ft 0 in 1 ft 5 in
1.11 0.27 N 40.0 ft2 8 ft 0 in 1 ft 5 in
Drapes/blinds
None
None
None
Drapesiblinds
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 315 ft2
315 ft2
24ft 8ft
11
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356
1375.7 75.53 142.04 .1233
7
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
SEER: 15 34.8 kBtu/hr drn
0.85 1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use SeWnt
Conservation
1 Electric
None
Garage
0.97 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
9/17/2019 9:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
DUCTS
_ / —Supply—
—Return—
Air
CFM 25
CFM25
HVAC#
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT ON RLF
Heat Cool
' 1 Attic
6 275 ft'
Attic
65 W
Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programabl[e Thermostart:,]Y
Ceiling Fans:
Heating [)� Jan Feb
[[ ]]
[X1 Mar
Apr
€
May
Jun
[[ ]]
[x] Jul
r[[ ]]
Aug
((
[X� Sep
Oct Oct rX']
Venting I Jan I 1 Feb
l J
[[�Xll Mar
May
lX� Jun
II 1) Jul
[ Aug
Lxl
[( Sep
lxl
lhl Occtt [X]
Nov
Dec
Thermostat- Schedule: -HERS 2006 Reference
Hours
_
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (WD) AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
78
78
78
78
78
78
78 78
78
78
Cooling (WEH) AM
78
78
78
78
78
78
78
78
78 78
78
78
PM
78
78
78
78
78
78
78
78
78 78
78
78
Heating (WD) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
Heating (WEH) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 lbs/sq.ft.
0 ft'
0 ft
0.3
BEDROOM
Default(8 lbs/sq.ft.
ft'
ft
0.3
WIC
Default(8 lbs/sq.ft.
ft'
ft
0.3
M. BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft'
ft
0.3
BATH
Default(8 lbs/sq.ft.
ft'
ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft'
ft
0.3
ENTRY
Default(8 lbs/sq.ft.
ft'
ft
0.3
LAUNDRY
Default(8 lbs/sq.ft.
ft'
ft
0.3
GREAT/DINING
9/17/2019 9:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
'2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT
Street: THE STERLING Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
Owner: Jurisdiction:
w
Design Location: FL, Fort Pierce
0
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall beinstalledin-the building envelope.
Air -permeable Insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceilinglattic
The air barrier in any dropped ceiling/soffit shall be aligned with
/soffit
The insulation in an dro ed ceiling/soffit
Y dropped 9
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed In the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind ninina and widna
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs,
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire qnrinkler cover plates and WgIls or ceilings
a. in addition, inspection of log walls snail be in accordance with the provisions of IOC400.
9/17/2019 9:05 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
'2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply duds R
6.0
2.. Single-family or -multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1474
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-fador:(weighted average)
7a.
1.060
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.284
14. Heating system: Capacity
34.8
c) Area
7c.
141.3
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
0 Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
0 Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
11.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
0 Programmable thermostat
Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home: THE STERLING 1 � AJS 1 QS` l City/FL Zip: FT. PIERCE. FL -� `1 5 5 2
9/17/2019 9:04:55 AM EnergyGaugeO USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
�d- wrightsoft- Project Summary
Entire House
QUICK CALCS, INC.
For. WYNNE DEVELOPMENT
THE STERLING, FT. PIERCE, FL
Job:
Date:
By.
Notes:
�\ �c'`� \v S SC BN�NED
St. Lurip r',nanti
Design Information
Weather.
Winter Design Conditions
Oufsidedb 42 OF
Inside db 70 OF
DesignTD 28 OF
Heating Summary
Structure
18188
Bluh
Ducts
5650
Btuh
Central vent (0 cfm)
Btuh
(none)
Humidification
0
Btuh
Piping
Equipment load
23842
BBtuh
Infiltration
Method
Construction quality
Fireplaces
Fort Pierce, FL, US
Simplified
Average
0
lin
Area (tt� He 1474. tinCo 1474
Volume(ite) 12227
12227
Airchangeslhour 0.45
0.23
Equiv. AVF(cfm) 92
47
Heating Equipment Summary
Make Carrier
Trade CARRIERAIR CONDITIONING
Model 25HBC536A`030
AHRI ref 7914585
Effidency
8.5 HSPF
Heating input
Heating output
34600
Btuh @ 47-F
Temperature rise
27
OF
Actual air flow
1160
cfirn
Airflowfactor
0.049
cfrn/Btuh
Static pressure
0.50
in H2O
Space thermostat
Capacity balance point= 33 OF
Backup:
Input=7kW, Output= 23009 Btuh, 100 AFUE
Calculations
Summer Design Conditions
Outside db
90
OF
Inside db
75
OF
Design TD
15
OF
Daily range
L
Relative humidity
50
%
Moisture difference
61
gr4b
Sensible Cooling Equipment
Load Sizing
Structure
17877
Btuh
Duds
8536
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Blower
0
Bluh
Use manufacturers data
n
Ratelswinqq multiplier
0.95
Equipment sensible load
25093
Btuh
Latent Cooling Equipment Load Sizing
Structure
2958
Btuh
Central
2310
vent (0 cfin)
Btuh
(none).
Equipment latent load
5277
Btuh
Equipment Total Load (Sen+Lat) 30370 Bluh
Req. total capacity at 0.70 SHR 3.0 ton
Cooling Equipment Summary
Make
Carrier
Trade
CARRIERAIR CONDITIONING
Cond
25HBC536MO30
Coil
FX4DN(B,F)037
AHRI ref
7914586
to meet all
Ad- Wr!gL",M* .
,vmyw Poglt-Sdiae ldoersal 201919.0.07 RSW8101
.aomenMWdahtsoftWAMWYNNE-TFESTERLWGnp Cale=MJS FrontOoorfaeesN
12.0 EER,15 SEER
24380 Btuh
`'f LE CM-SY)
6.50 to H2O
oat ratio 0.83
REVIEWED FOR
., ,,,r,= r-OMPL.IANCE
'Za19�ep-17 09a1:10
Y Page
9
0
�m
NA
W
N
N
+' OI
NAWN+
p-1
O fnA
N
3
E m.
S+
f M 'n nv
im
RL
8
8
�_
r. _
_
ail
Er
N3 US FdS US
6
„
Oo�00o00{3{3,,,youy {�}�po ppo
i tO NtO�oW 6fJ 4f�p0 WW.
ec
J0
•. , VQ{.� NLi"A YnA401n AYnA
�
�,
..J�
j
(p4y1f
�
JWA
e
N
y4...
(!�J�.f yy
A>NAWOVOAN>NW mob.
�'^
VI 4)
•. N>NOOV NLf A.NAWON:
p_�{�a^j'
ON
j�j�j md_
Am 000
m
m
O
pN�
WN
ym pp. ��.Wp
•.O NONV VA N'.WN+(y�A m�!
N
I -
S
n
Ow
��000
�.
00
y
OIJ
�i
p
;'OfO OIA m-+WVOI:A fO ON A':
On
N
� f�p iE00(WJ N.OA OOObO O
�'^
� O
• �,�i }3o0omo�Aaoo oo o,
�
N�
�+O
G 000
O�
IIIJO
h 'ON OONOl;OV000000,.
O
roN
tN0'N OOO
'0
OO
OfAp
V
O
41
fp WOOON-O OOOOOO L.
ICE
d O
C
M.
-
P
Poo
0.. 000.. ooq,.!g."
00000. . .
14
00
06 0
8888
88E
Li
Ell
K
ji
O N �
-,o m
01
2
�a
8
� r0• f T
lV
Q O K
'OP
(LN
OO 00000 OO OO N.N • - A 1
P
�
�r
'1
m
dd
F
LO
��
JJJ
OOO OO p000001aN0
I�
��
N
U7
Fo x
o0000000000�'.0
g,
�
m N
000000ao 000�N.�
m,
o
e
N-Na
N^ NNt\INY)I��N.O-
��
r,i
��
A
SSS�i�oSSiS9t� "
k �
600�
cr a occ�o
QCSc; ooCS,
JI�
�aV,u
M
0
a
2
wrightsoft, Right-J@ Worksheet Job:
Entire House Date:
QUICK CALCS, INC. BY.,
317 ST. LUCE LN., FT. PIERCE, FL 34946 Phom:772-466-6799 Fes772-466-6796 Emil: QUICKCALCS@AOLCOM
1
Room name
BEDROOM2
ENTRY
2
EVosedvdl
322 ft
7.0 ft
3
Room helght
8.0 R heaV=l
8jo ft heatimol
4
Room crimursiorm
1.0 x 203.5 ft
1.0 x 55.0 ft
5
Rvcmarea
203.5 ft2
55.0 f12
Ty
Comitudon
1.1-value
or
HTM
Area (IF)
Load
AM M
Load
number
(13tuhWF)
(BUhffl
---F-
or perimeter (f)
(Bub)
or perimter (f)
(Bbuh)
Het
Cool
Gloss
NIFIS
Heat
Cool
Gross
NIPS
1-1,4
Cool
6
014
rid
w.O
4 z
-128
'128
513
'32S
0'
0
0
w
M-4=
r1270
r)E�
.---3"9
AM
0
'0
1, ()
.. . -�o
— 1
'0'
�"�'o
",10
- �to
—'O
0.143
w
4.00
2.55
80
56
225
143
48
26
106
67
1Aclo rn
1270
se
35M
34.77
24
24
$48
INS
0
0
0
0
11
1100
0.390
w
10.92
11.31
0
0
0
0
22
22
236
244
',13AA="-"
0.143
1,3
.4.06
255
-134
34
-7136',
0
-6
0
0
13A4=
0 ' 143
w'
4 "
16
18
64
41
8
8
32.
20
1270
w
35.56
42.91
0
0
0
a
0
0
0
50EM
w
z0b
12,55
—
'o
... -0
0
1L. I 'o
q
1270.
w
.3556
4524
�O
o
0
0
�1'0
"0
0.7701�
r1w'
...21.56
.77.54
0..
:0
1':
%�,O
"0
P
12c-ow
0.0911
2,
551,
_ 1.2811
01
0.
ol
0
I 72
72
182
A2
12
a) Infilbation
5641
154
122
34
b) Roorrivenflaton
0
0
0
0
13
Inbsmal gam: Oxupants@ 230
1
230
01
0
AppriancesbMer
0
0
SubIodOjnw6IoI3)
3422
2257
922
579
Le eclamalfoad
0
0
0
0
I-miransler
0
0
0
0
Reclisbibuton
0
0
0
0
14
SLftW
3122
2257
922
579
16
Ductimcls
31%
48%1
1064
I0781
31%
'w/.
2871
271
Total room load
1
"86
33351
1209
85,1
5i
Airrequired(clim)
218
1461
591
38
Calculadons approved WACCAto meetall requirements of Manual J 8th Ed
Riglid-Sat's LhwrSa12OI919.0.07RSLI08I01 2019-Sep-170921:11
.XanlerbkWdgffzoftWADWYNW-,THESTERUNGAp Calc=MJB Fmr1I)oorfawxN Pa9e4
I wrighttsoft, Right-J® Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST. LUCIE LM, Fr. PIERCE, FL 34940 Prore:772466-6799 Fa;c 72-466-8796 Email: OUICKCALCS@AOL.COM
1
R'oom nacre
LAUNDRY
GREATIDINING
8.0 it
46.0 R
3
Room height
80 it heaYbool
8.9 R heatbool
4.
Reomdmensom
7.0 x 6.0 R
1.0 x 488.0 R
5
Room area
420 IF
488D 10
Ty
COn&LdOn
U-vdue
Or
HTM
Area (to)
Load
Area
Load
number
(BWhdL*q
(fialM
or perimeter (f0
(BWh)
a pedme (fq
(Bfuh)
Heat
Cod
Gros
NIPS
Heat
Cool
Gross
I NIPS
Heat
Cool
6
V,V
13A'4061
0143
ne
=4.00
:2.55
: 0
'. 0
-r 0
- '-0
231
194
":' 775
`,'493
-�---G
W -
SActom -_,;...
13A-0ar
..' _�1270
`ne
r-.'35.56
"70.43
` -.0
p
�.--:-_ _0
._ :,.�.0
._.�_.��
:' -, .,.0
_"""'1394
.":`=2662
0.143
w
4.00
2.55
0
0
0
0
0
0
0
0
c1
1Aom
1270
s
35.56
34.77
0
0
0
0
0
0
0
0
11
11DO
0390
M
%92
11.31
0
0
0
0
0
0
0
0
..` 0.143
` si7
.4.00
255'
"255
--0
•..: -0'
-'
- 0:.
'.0
- - t � b
0
-; _. 0
- 0
W
LG
134-4as
1At1om
0.143
sx
4.00
48
48
- 192
1Y2
. 0
0
.< 0
,
0
1270
ax
3556
42.91
0
0
0
0
0
0
0
0
13446ce
1Ac1om
- 0.143
W'
`4A0
3556
2S5
�' 0
- 0
0
0
178
; 137
� 540
-
349
1270
rw
'.
4524
�,
0
0
g
0
0:
0
0
;-0.
0:770
MY
; 2156
27.54
.' .0
. � 0
�- 0
1 • ' 0
41
. , 0
; 880
` -1124
P
12C-0sx
0.091
2.55
128
56
56
143
72
0
0
0
0
C
[784.30md s.
`=.0.032
r-(.ORD
Y`'232
: 42
-.,. 42
' -38
:. ."97
:,488
:• _ 458
437K1132
F _
71A-ml
Q989
. .
27.69
0.00
42
6
166
. 0
48e
46
- ,-<
1274
0
IF
6
c)AEDe7�on
12I -b R LIN6mwnfilalon I I I on 1 0I 291 01
I 890 2 CI
13 Internal gains O=Ipank@ 230 1 Ol I I Ol 21 1 1 460
Lese&malload
0
0
0
0
Lmtransfer
0
0
0
0
Reclsbibuton
0
0
0
0
14
Subtotal
644
31
-
6154
6409
15
Dudl=ds
31%
481/a
200
151
31%
480%
1913
3060
-
Total reomload
Airrequired ad
844
468
8
94M
Calculafions approved WACCAto meet all requirements of Manual J 8th Ed
2019•SepA70931:11
Aft R-THE to ERUN rs12 Cala=0.07 RSL108101 Page 5
_oamerPslWdgfisoftHVAC,WYNNE-THE STERLWGnp CaIc=MJe Frorigoorfaces: N -
-Fd- wrightsoft° Duct System Summary Jam:
Entire House By:
QUICK CALCS, INC.
317ST.LUCIELIA.FT.PIEROE.FL34946Phore:772-466-6799Fa 772-46"796 EMII:OU1CKCALCS@ji0AOL.COM
For. WYNNE DEVELOPMENT
THE STERLING, FT. PIERCE, FL
Heating
Cooling
External static pressure
0.50
in H2O
0.50
in H2O
Pressure losses
0
in H2O
0
in H2O
Available static pressure
0.50
in H2O
0.50
in H2O
Supply / realm available pressure
0.250 / 0250
in H2O
0.250 / 0250
in H2O
Lowest friction rate
0.284
in/100ft
0284
in/100ft
Actual air flow
1160
clm
1160
cIrn
Total effective length (TEL)
176 fit
Name
Design
(Btuh)
Htg
(dim)
Clg
(dim)
Design
FR
Diam
(in)
HxW
(in)
Duct
Mail
Actual
Ln (ft)
Ftg.Egv
Ln (it)
Trunk
BATH
h 559
27
15
0.376
4.0
Ox0
VIFx
18.1
115.0
sH
SEDROOM2
h 4486
218
146
0.374
6.0
OxO
VIFx
18.6
115.0
SO
ENTRY
h 1209
59
38
0.510
4.0
Ox0
VIFx
3.0
95.0
GREAT/DIMNG
c 4735
196
208
0.318
7.0
OxO
VIFx
22.4
135.0
s12
GREATmIMNG-B
c 4735
196
208
0.307
7.0
Ox0
VIFx
28.1
135.0
s2
KrrCHEN
c 3695
21
162
0.375
7.0
OxO
VIFx
18.3
115.0
st1
LAUNDRY
h 844
41
21
0.366
6.0
Ox0
VIFx
21.6
115.0
all
KBATH
h 1162
57
54
0.366
4.0
OxO
VIFx
21.6
115.0
st1
MASTERBEDROOwA
h 3501
170
149
0.297
6.0
OxO
VIFx
33.1
135.0
st2
MASTERBEDROOM-B
h 3501
170
149
0284
6.0
Ox0
VIFx
41.1
135.0
st2 -
wIc
o 214
4
9
0.310
4.0
OxO
VIFx
26.3
135.0
st2
Trunk
Htg
Clg
Design
Veloc
Diam
HxW
Dud
Name
Type
(cfm)
(cfm)
FR
(fpm)
(in)
(In)
Material
Trunk
st2
PeakAUF
737
724
0284
938
12.0
0 x 0
VinlFlx
st1
st1
PeakAVF
1101
1122
0284
1050
14.0
0 x 0
VinlFlx
.� -Fj&- wrightsof - 2019SeF'1709J31:11
,Po9IESJteODL iw=1201919.0.07RSL[08101 Pagel
` ` ...00 rtlWrigNsoft WUAC1WYNNE•THESTERUNGnp Calc=MJ8 FrorLDoorfaces: N
Name
Grille
Size (in)
Htg
(Cfm)
Clg
(cfm)
TEL
(ft)
Design
FR
Veloc
(fpm)
.Diam
I (in)
H x W
(n)
Stud/Joist
Opening (in)
Dud
Mati
Trunk
rb1
Ox0
1160
1 1160
07
0
0
0
Ox 0
VIFx
-Fk Wrightroft- 2019-Sep-170991:11
C ,.�Right SufeOlkiwMl 201919.0.07 RS W8101 Page z
lamertlWrigNsoftWAQWYNW--TFESTERLWGnp Calc=MJ8 FrortDoorfaces: N