HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 -FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE STERLING IMPACT Street: THE STERLING Builder Name: WYNNE DEVELOPMENT r1�® ��AN1VSCANNEDCity, < State, Zip: FT. PIERCE, FL, ` Permit Office: ST. LUCIE COUNTY BY Permit Number: Owner: Jurisdiction: �+ St. LuCtA rnllnttr Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New _(From -Plans) - 9. Wall Types (1442.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft' b. Frame - Wood, Adjacent R=11.0 192.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 2 d. N/A R= ft' 5. Is this a worst case? Yes 10. Ceiling Types (1474.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1474.00 ft' 6. Conditioned floor area above grade (ft') 1474 b. N/A R= ft' Conditioned floor area below -grade 0 c. NIA R= ft' 11. Ducts R ft' 7. Windows(141.3 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 275 a. U-Factor: Sgl, U=1.04 101.25 ft' SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 40.00 ft' 12. Cooling systems kBtulhr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEERA5.00 c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.284 14. Hot water systems 8. Floor Types (1473.5 sgft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft' b. Conservation features EF: 0.970 b. N/A R= ft' None c. N/A R= ft' 15. Credits Pstat Total Proposed Modified Loads: 47.03 Glass/Floor Area: 0.096 PASS Total Baseline Loads: 48.47 1 hereby certify that the plans and specifications covered by Review of the plans and Sy 9l� this calculation are in compliance with the Florida Energy specifications covered by this 04If%E Code. calculation indicates compliance with the Florida Energy Code. mr,"•, .'k.':y' PREPARED BY: Before construction is completed DATE: � this building will be inspected for PC a 0 y compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. C'op WB �O OWNER/A BUILDING OFFICIAL: DATE: DATE:Q - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACHR EIRE 92ED FOR F1, WOO_ CvD!Uv.: BOCC • 9/17/2019 9:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE STERLING IMP Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1474 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE STERLING Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / ,Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1474 11792 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 329 2632 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M. BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 329 ft' — 0 1 0 2Slab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft' _- 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft' _- 0 1 0 48Iab-On-Grade Edge Insulatio KITCHEN 1 ft 0 192 ft' ___ 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft' ___ 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft' 0 1 0 7SIab-On-Grade Edge Insulatio ENTRY 7 ft 0 55 ft' __ 0 1 0 9/17/2019 9:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8SIab-On-Grade Edge Insulatio LAUNDRY Eft 0 42 ft2 0 1 0 9Slab-On-Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 ---- 0 1 0 ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 _ Gable cr.Shed - -Metal- - 1553 ft2 246 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1474 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 329 R2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M.BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE=>SW Exterior Concrete Block - Ext InsiBEDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 2 SW=>NE Exterior Concrete Block - Ext Ins®EDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.4 0 3 NW=>SE Exterior Concrete Block - Ext Ins®EDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 5 NE=>SW Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 6 NE=>SW Exterior Concrete Block - Ext InZIEDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.4 0 7 SE=>NW Exterior Concrete Block - Ext InSEDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 8 S=>N Exterior Concrete Block - Ext IndlEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.4 0 9 SW=>NE Exterior Concrete Block - Ext IndilEDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0 10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 12 SW=>NE Exterior Concrete Block - Ext InsdIAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 13 NE=>SW Exterior Concrete Block - Ext InsGREAT/DINI 4.1 26 0 8 0 208.0 ft2 0 0 0.4 0 14 NW=>SE Exterior Concrete Block - Ext InsGREAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.4 0 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft2 0.23 0.4 0 9/17/2019 9:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal - 3 -SE=>NW 7 Metal 4 NE=>SW13 Metal 5 NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes _ Yes_ Yes Yes Yes 1.04 0.29 N 32.9 ft' 1 ft 0 in 1 ft 5 in 1.04 -0.29 N -6.9 ft' -1 ft-0 in 1 ft 5 in 1.04 0.29 N 24.0 ft' 6 ft 0 in 1 ft 5 in 1.04 0.29 N 37.5 ft' 1 ft 0 in 1 ft 5 in 1.11 0.27 N 40.0 ft' 8 ft 0 in 1 ft 5 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft' 315 ft' 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgI.A ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1375.7 75.53 142.04 .1233 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft' 9/17/2019 9:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DUCTS / — Supply — -- Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 275 ft2 Attic 65 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablre'Thermostat: CApr[[eiling Fans: ,]Y Heating Jan Feb r' [X] Mar [� ]j L.l JMay un rX� [ ] Jul [[ ]] I I Aug [[` ]]] ri Sep [ ] [rX,] L.1 Nov[[X]� Dec Venting I 1 Jan I 1 Feb L l l l IX1 Mar ll�xll Apr [ May Jun [) Jul [[ ]) Aug [) Sep lxl Oct -[X] Nov [-] Dec Thermostat Schedule: HERS -2006-Refeirence Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibslsq.ft. 0 ft2 0 ft 0.3 BEDROOM Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Default(8 lbs/sq.ft. ft2 ft 0.3 M. BATH Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 BATH Default(8 Ibs/sq.ft. ft' It 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft2 ft 0.3 ENTRY Default(8 lbs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 lbs/s.ft. ft2 ft 0.3 GREAT/DINING 9/17/2019 9:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. Y U Owner: Jurisdiction: W Design Location: FL, Fort Pierce c=i COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA .General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the lop of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind nqninn and wirmno Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. I Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ce no� a. in accicon, inspection of log walls shall be in accordance with the provisions of ICC-400. 9/17/2019 9:05 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts- R -6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1474 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.060 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.284 c) Area 7c. 141.3 S. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.1 14. Heating system: Capacity 34.8 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE 0 Other 15. Water heating system a) Electric resistance EF 0.97 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF 0 Heat recovery unit HeatReC% g) Other 10B1. 11.0 10132. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 30.0 b) Cross ventilation No 11b. c) Whole house fan No 11 c. d) Multizone cooling credit 11d. No e) Multizone heating credit 0 Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: THE STERLING !J, Tt4�AC `Qwt ! City/FL Zip: FT. PIERCE. FL 34 01T -1 9/17/2019 9:04:49 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 I wrightsoft0 Project Summary Entire House QUICK CALCS, INC. Job: Date: By. Far. WYNNE DEVELOPMENT THE STERLING, FT, PIERCE, FL c� SCANNED Notes: BY - - - - -St- Lucie Cnnnfiur Design Information Weather. Winter Design Conditions . Outside db 42 OF Inside db 70 . OF DesignTD 28 OF Heating Summary Structure 18188 Btuh Ducts 5650 h Central vent (0 cfrn) BBtuh (none) Humidification 0 Btuh Piping 0 Btuh Equipmentload 23842 Btuh Method Construction quality Fireplaces V�ul me(13) Airchar�lae�slhour Equiv.AVF (cfm) Infiltration Fort Pierce, FL, US Simplified Average 0 Heolin 1474 Co1474 12227 12227 0.45 0.23 92 47 Heating Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Model 25HBC536KO30 AHRI ref 7914685 Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr4b Sensible Cooling. Equipment Load Sizing Structure 17877 Btuh 8530 Centralvent (0 cfm) BBtuh (none) Blower 0 Btuh Use manufacturers data n Rate/swingg multipplier 0.95 Equipmerltsensibleload 25093 Bluh Latent Cooling Equipment Load Sizing Structure 2958 Btuh 2310 . Btu Central vent (0 cfm) BBbuh (none) Equipment latent load 5277 Btuh Equipment Total Load (Sen+Lat) 30370 Btuh Req. total capacity at 0.70 SHR 3.0 ton Cooling Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Cond 25HBC536A'030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER,15 SEER Heatingmput Heating output 34600. Btuh @47°F Sensible cooling 24360 Btuh Lateritcooling 10440 Btuh Temperature rise 27 OF Total cooling 34800 Btuh Actual air flow 1160 cfm . Actual. airflow 1160. chn Airflowfactor 0.049 cfrn/Btuh Airflowfactor 0.044 chnBtuh Spaph0.50 in H2O cetermostat Staticsin H2O Loasensible hpAREWED R Capacity balance point =33'F CODE �'.sOMPLI E Backup AWi Input=7kW, Output= 23009 Btuh, 100 AFUE STD LUCIE COUN" Calculations approved byACCA to meet all requirements of Manual,`C 4- W�r.�h"AM7 "»-^mow+ Riga-Su<e®URverSW201919.0.07RSW8101 aMarAlWnghtS0ft /AQWYNNE-hE STERLNGnp Cale=Ml8 Frort 2019Sep-1709�110 PagelOoorfacesN - i O m c� G J r 3 cl O N � 0 r m 3- H m6 I -i G m L V 3 .61 N 0 O N r u 0 M Im Ll O 'I sl 7", 77. 17 zo x 12 fMs iz;;; UIMN; CWR 0. rm tq oav tq a 8 4g c I J, EECw OC T jlE IMMIX wwo -,fw F, �-. Z5 0 Duct System Summary Job: -�- wrightsoft y rY Data: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE"FT.PIERCE. FL 34946 Plow: 772-466.6799F=772-466-6796 E=!]:QUICKCALCS AOL.COM For. WYNNE DEVELOPMENT THE STERLING, FT. PIERCE, FL Extemal static pressure Pressurelosses Available static pressure Supply / return available pressure Lowestftidon rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.284 in/100ft 1160 cftrl 176 it Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250/0.250 in H2O 0.284 in/100ft 1160 elm Name Design (Btuh) Hlg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftgg.Egv. Ln (ft) Trunk BATH h 559 27 15 0.376 4.0 OxO VIFx 18.1 115.0 st1 BEDROOM2 h 4486 218 146 0.374 6.0 OxO VIFx 18.6 115.0 st1 ENTRY h 1209 59 38 0.510 4.0 Ox0 VIFx 3.0 95.0 GREATIDINING c 4735 196 208- 0.318 7.0 OxO VIFx 22A 135.0 st2 GREATIDINING-B c 4735 196 208 0.307 7.0. OxO VIFx 28.1 135.0 st2 KITCHEN c 3695 21 162 0.375 7.0 OxO VIFx 18.3 115.0 st1 LAUNDRY h 844 41 21 0.366 6.0 OxO VIFx 21.6 115.0" st1 M. BATH h 1162 57 54 0.366 4.0 Ox0 VIFx 21.6 115.0 st1 MASTERBEDROOM-A h 3501 170 149 0.297 6.0 Ox0 VIFx 33.1 135.0 s112 MASTER BEDROOM-B h 3501 170 149 0.284 6.0 OxO VIFx 41.1 135.0 st2 wlc c 214 4 9 0.310 4.0 OxO VIFx 26.3 135.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam HxW Dud Name Type (curl) (cfm) FR (fpm) (n) (n) Material Trunk st2 PeakAVF 737 724 0.284 938 12.0 0 x 0 VinlFix st1 st1 PeakAVF 1101 1122 0.284 1050 14.0 0 x 0 MnIFlx wrightsoft' 2019SeF170"1:11 ti ..w, w«nm...,,RJgtFSUteDUriwml20l9l9.0.07RSU09101 Page �a rb%WdgtLwftFIVAC\WYNNE-THESTERLWGnp Ca1c=W8 FMriDaorfaces:N Name Grille Size pn), Htg (dm) Clg (cfm) TEL (ft) Design FR Neloc (ipm) Diam (in) H x W (n) Stud/Joist Opening (in) Dud Mal Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 VIFx C A&- wriggfiwd..• tsd! - W < wn MgNSd" UNvereat 201919.0.07 RSWzots-sep-n osat:ll8107 Fegez .-ea rb%WdgtWRWAQWfNNE-THESTERLNGAp UG=MJ8 FmrtDoorfaw%N