-FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE STERLING IMPACT
Street: THE STERLING
Builder Name: WYNNE DEVELOPMENT
r1�®
��AN1VSCANNEDCity,
<
State, Zip: FT. PIERCE, FL, `
Permit Office: ST. LUCIE COUNTY
BY
Permit Number:
Owner:
Jurisdiction:
�+
St. LuCtA rnllnttr
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New _(From -Plans) -
9. Wall Types (1442.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1250.00 ft'
b. Frame - Wood, Adjacent
R=11.0 192.00 ft'
3. Number of units, if multiple family 1
c. N/A
R= ft'
4. Number of Bedrooms 2
d. N/A
R= ft'
5. Is this a worst case? Yes
10. Ceiling Types (1474.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1474.00 ft'
6. Conditioned floor area above grade (ft') 1474
b. N/A
R= ft'
Conditioned floor area below -grade 0
c. NIA
R= ft'
11. Ducts
R ft'
7. Windows(141.3 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 275
a. U-Factor: Sgl, U=1.04 101.25 ft'
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.11 40.00 ft'
12. Cooling systems
kBtulhr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEERA5.00
c. U-Factor: N/A ft'
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft'
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.284
14. Hot water systems
8. Floor Types (1473.5 sgft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft'
b. Conservation features
EF: 0.970
b. N/A R= ft'
None
c. N/A R= ft'
15. Credits
Pstat
Total Proposed Modified Loads: 47.03
Glass/Floor Area: 0.096
PASS
Total Baseline
Loads: 48.47
1 hereby certify that the plans and specifications covered by
Review of the plans and
Sy 9l�
this calculation are in compliance with the Florida Energy
specifications covered by this
04If%E
Code.
calculation indicates compliance
with the Florida Energy Code.
mr,"•, .'k.':y'
PREPARED BY:
Before construction is completed
DATE: �
this building will be inspected for
PC a
0 y
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
C'op WB �O
OWNER/A
BUILDING OFFICIAL:
DATE:
DATE:Q
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACHR EIRE 92ED FOR
F1, WOO_ CvD!Uv.:
BOCC
• 9/17/2019 9:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE STERLING IMP Bedrooms: 2
Address Type:
Street Address
Building Type: User Conditioned Area: 1474
Lot #
Owner Name: Total Stories: 1
Block/Subdivision:
# of Units: 1 Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180
Street:
THE STERLING
Permit Office: ST. LUCIE COUNTY Cross Ventilation: No
County:
St. Lucie
Jurisdiction: Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/ ,Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1474 11792
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 BEDROOM 329 2632 No 0
1
1 Yes
Yes
Yes
2 WIC 63 504 No 0
1 No
Yes
Yes
3 M. BATH 56 448 No 0
1 Yes
Yes
Yes
4 KITCHEN 192 1536 Yes 0
1 No
Yes
Yes
5 BATH 45 360 No 0
1 Yes
Yes
Yes
6 BEDROOM 2 204 1632 No 0
1
1 Yes
Yes
Yes
7 ENTRY 55 440 No 0
1 Yes
Yes
Yes
8 LAUNDRY 42 336 No 0
1 Yes
Yes
Yes
9 GREAT/DINING 488 3904 No 0
1 Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0
329 ft'
—
0 1
0
2Slab-On-Grade Edge Insulatio WIC 1 ft 0
63 ft'
_-
0 1
0
3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0
56 ft'
_-
0 1
0
48Iab-On-Grade Edge Insulatio KITCHEN 1 ft 0
192 ft'
___
0 1
0
5 Slab -On -Grade Edge Insulatio BATH 5 ft 0
45 ft'
___
0 1
0
6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0
203.5 ft'
0 1
0
7SIab-On-Grade Edge Insulatio ENTRY 7 ft 0
55 ft'
__
0 1
0
9/17/2019 9:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8SIab-On-Grade Edge Insulatio LAUNDRY Eft
0
42 ft2
0
1
0
9Slab-On-Grade Edge Insulatio GREAT/DINING 46 ft
0
488 ft2
----
0
1
0
ROOF
Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
V # Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 _ Gable cr.Shed - -Metal- - 1553 ft2
246 ft2
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
/
V # Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
150
1474 ft2
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Free
Truss Type
1 Under Attic (Vented) BEDROOM
30
Blown
329 R2
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented) M.BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
7 Under Attic (Vented) ENTRY
30
Blown
55 ft2
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
9 Under Attic (Vented) GREAT/DINING
30
Blown
488 ft2
0.1
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing Solar
Below
1 NE=>SW Exterior Concrete Block - Ext InsiBEDROOM
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
2 SW=>NE Exterior Concrete Block - Ext Ins®EDROOM
4.1 28
0 8
0
224.0 ft2
0
0
0.4
0
3 NW=>SE Exterior Concrete Block - Ext Ins®EDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.4
0
4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.4
0
5 NE=>SW Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.4
0
6 NE=>SW Exterior Concrete Block - Ext InZIEDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.4
0
7 SE=>NW Exterior Concrete Block - Ext InSEDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
8 S=>N Exterior Concrete Block - Ext IndlEDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.4
0
9 SW=>NE Exterior Concrete Block - Ext IndilEDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.4
0
10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY
4.1 6
0 8
0
48.0 ft2
0
0
0.4
0
11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY
4.1 1
0 8
0
8.0 ft2
0
0
0.4
0
12 SW=>NE Exterior Concrete Block - Ext InsdIAUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.4
0
13 NE=>SW Exterior Concrete Block - Ext InsGREAT/DINI
4.1 26
0 8
0
208.0 ft2
0
0
0.4
0
14 NW=>SE Exterior Concrete Block - Ext InsGREAT/DINI
4.1 20
0 8
0
160.0 ft2
0
0
0.4
0
15 N=>S Garage Frame - Wood KITCHEN
11 24
8
192.0 ft2
0.23
0.4
0
9/17/2019 9:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
DOORS
# Ornt
Door Type
Space
Storms U-Value Width
Ft In
Height
Ft In
Area
1 SE=>NW
Insulated
ENTRY
None .39 3 1
6 8
20.6 ft'
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
V # Ornt ID Frame
Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
- 3 -SE=>NW 7 Metal
4 NE=>SW13 Metal
5 NW=>SE14 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
_ Yes_
Yes
Yes
Yes
1.04 0.29 N 32.9 ft' 1 ft 0 in 1 ft 5 in
1.04 -0.29 N -6.9 ft' -1 ft-0 in 1 ft 5 in
1.04 0.29 N 24.0 ft' 6 ft 0 in 1 ft 5 in
1.04 0.29 N 37.5 ft' 1 ft 0 in 1 ft 5 in
1.11 0.27 N 40.0 ft' 8 ft 0 in 1 ft 5 in
Drapes/blinds
None
None
None
Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 315 ft'
315 ft'
24ft 8ft
11
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgI.A ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356
1375.7 75.53 142.04 .1233
7
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
SEER: 15 34.8 kBtu/hr cfm
0.85 1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric
None
Garage
0.97 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft'
9/17/2019 9:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
DUCTS
/ — Supply
—
-- Return —
Air
CFM 25
CFM25
HVAC #
V # Location R-Value
Area
Location
Area
Leakage Type
Handler
TOT
OUT ON RLF
Heat Cool
1 Attic 6
275 ft2
Attic
65 ft2
Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programablre'Thermostat:
CApr[[eiling Fans:
,]Y
Heating Jan Feb
r'
[X] Mar
[� ]j
L.l
JMay un
rX�
[ ] Jul
[[ ]]
I I Aug
[[` ]]]
ri Sep
[ ] [rX,]
L.1
Nov[[X]�
Dec
Venting I 1 Jan I 1 Feb
L l l l
IX1 Mar
ll�xll Apr
[
May
Jun
[) Jul
[[ ]) Aug
[) Sep
lxl Oct -[X]
Nov
[-] Dec
Thermostat Schedule: HERS -2006-Refeirence
Hours
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (WD) AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
78
78
78
78
78
78
78 78
78
78
Cooling (WEH) AM
78
78
78
78
78
78
78
78
78 78
78
78
PM
78
78
78
78
78
78
78
78
78 78
78
78
Heating (WD) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
Heating (WEH) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibslsq.ft.
0 ft2
0 ft
0.3
BEDROOM
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC
Default(8 lbs/sq.ft.
ft2
ft
0.3
M. BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft2
ft
0.3
BATH
Default(8 Ibs/sq.ft.
ft'
It
0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
ENTRY
Default(8 lbs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 lbs/s.ft.
ft2
ft
0.3
GREAT/DINING
9/17/2019 9:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT
Street: THE STERLING Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number.
Y
U
Owner: Jurisdiction:
W
Design Location: FL, Fort Pierce
c=i
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
.General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the lop of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind nqninn and wirmno
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
I
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and walls or ce no�
a. in accicon, inspection of log walls shall be in accordance with the provisions of ICC-400.
9/17/2019 9:05 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the Energy Performance Index, the more efficient the home
1. New home or, addition
1.
New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts-
R
-6.0
2. Single-family or multiple -family
2.
Single-family
b) Return ducts
R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system:
Capacity
34.8
a) Split system
SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package
SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1474
d) Room unit/PTAC
EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average) 7a. 1.060
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.284
c) Area 7c. 141.3
S. Skylights
a) U-factor:(weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
10A2. 4.1
14. Heating system: Capacity 34.8
a) Split system heat pump HSPF 8.5
b) Single package heat pump HSPF
c) Electric resistance COP
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
0 Other
15. Water heating system
a) Electric resistance EF 0.97
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF
0 Heat recovery unit HeatReC%
g) Other
10B1. 11.0
10132.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11a. 30.0
b) Cross ventilation No
11b.
c) Whole house fan No
11 c.
d) Multizone cooling credit
11d. No
e) Multizone heating credit
0 Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home: THE STERLING !J, Tt4�AC `Qwt ! City/FL Zip: FT. PIERCE. FL 34 01T -1
9/17/2019 9:04:49 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
I
wrightsoft0 Project Summary
Entire House
QUICK CALCS, INC.
Job:
Date:
By.
Far. WYNNE DEVELOPMENT
THE STERLING, FT, PIERCE, FL c� SCANNED
Notes: BY
- - - - -St- Lucie Cnnnfiur
Design Information
Weather.
Winter Design Conditions .
Outside db 42 OF
Inside db 70 . OF
DesignTD 28 OF
Heating Summary
Structure
18188
Btuh
Ducts
5650
h
Central vent (0 cfrn)
BBtuh
(none)
Humidification
0
Btuh
Piping
0
Btuh
Equipmentload
23842
Btuh
Method
Construction quality
Fireplaces
V�ul me(13)
Airchar�lae�slhour
Equiv.AVF (cfm)
Infiltration
Fort Pierce, FL, US
Simplified
Average
0
Heolin
1474
Co1474
12227
12227
0.45
0.23
92
47
Heating Equipment Summary
Make Carrier
Trade CARRIERAIR CONDITIONING
Model 25HBC536KO30
AHRI ref 7914685
Summer Design Conditions
Outside db
90
OF
Inside db
75
OF
Design TD
15
OF
Daily range
L
Relative humidity
50
%
Moisture difference
61
gr4b
Sensible Cooling. Equipment
Load
Sizing
Structure
17877
Btuh
8530
Centralvent (0 cfm)
BBtuh
(none)
Blower
0
Btuh
Use manufacturers data n
Rate/swingg multipplier 0.95
Equipmerltsensibleload 25093 Bluh
Latent Cooling Equipment Load Sizing
Structure
2958
Btuh
2310 .
Btu
Central vent (0 cfm)
BBbuh
(none)
Equipment latent load
5277
Btuh
Equipment Total Load (Sen+Lat) 30370 Btuh
Req. total capacity at 0.70 SHR 3.0 ton
Cooling Equipment Summary
Make
Carrier
Trade
CARRIERAIR CONDITIONING
Cond
25HBC536A'030
Coil
FX4DN(B,F)037
AHRI ref
7914585
Efficiency 8.5 HSPF
Efficiency 12.0 EER,15 SEER
Heatingmput
Heating output 34600. Btuh @47°F
Sensible cooling 24360 Btuh
Lateritcooling 10440 Btuh
Temperature rise 27 OF
Total cooling 34800 Btuh
Actual air flow 1160 cfm .
Actual. airflow 1160. chn
Airflowfactor 0.049 cfrn/Btuh
Airflowfactor 0.044 chnBtuh
Spaph0.50 in H2O
cetermostat
Staticsin H2O
Loasensible hpAREWED R
Capacity balance point =33'F
CODE �'.sOMPLI E
Backup
AWi
Input=7kW, Output= 23009 Btuh, 100 AFUE
STD LUCIE COUN"
Calculations approved byACCA to meet all requirements of Manual,`C
4- W�r.�h"AM7
"»-^mow+ Riga-Su<e®URverSW201919.0.07RSW8101
aMarAlWnghtS0ft /AQWYNNE-hE STERLNGnp Cale=Ml8 Frort
2019Sep-1709�110
PagelOoorfacesN -
i O m
c�
G
J
r
3
cl
O N �
0
r
m
3-
H
m6
I
-i G m
L
V
3
.61
N
0
O N
r
u
0 M
Im
Ll
O
'I
sl
7",
77.
17
zo x
12
fMs iz;;; UIMN; CWR 0.
rm
tq oav tq a 8
4g
c
I
J, EECw
OC
T
jlE
IMMIX
wwo
-,fw
F,
�-. Z5
0
Duct System Summary Job:
-�- wrightsoft y rY Data:
Entire House By:
QUICK CALCS, INC.
317 ST. LUCIE"FT.PIERCE. FL 34946 Plow: 772-466.6799F=772-466-6796 E=!]:QUICKCALCS AOL.COM
For. WYNNE DEVELOPMENT
THE STERLING, FT. PIERCE, FL
Extemal static pressure
Pressurelosses
Available static pressure
Supply / return available pressure
Lowestftidon rate
Actual airflow
Total effective length (TEL)
Heating
0.50
in H2O
0
in H2O
0.50
in H2O
0.250 / 0.250
in H2O
0.284
in/100ft
1160
cftrl
176 it
Cooling
0.50
in H2O
0
in H2O
0.50
in H2O
0.250/0.250
in H2O
0.284
in/100ft
1160
elm
Name
Design
(Btuh)
Hlg
(cfm)
Clg
(cfm)
Design
FR
Diam
(in)
H x W
(in)
Duct
Matl
Actual
Ln (ft)
Ftgg.Egv.
Ln (ft)
Trunk
BATH
h 559
27
15
0.376
4.0
OxO
VIFx
18.1
115.0
st1
BEDROOM2
h 4486
218
146
0.374
6.0
OxO
VIFx
18.6
115.0
st1
ENTRY
h 1209
59
38
0.510
4.0
Ox0
VIFx
3.0
95.0
GREATIDINING
c 4735
196
208-
0.318
7.0
OxO
VIFx
22A
135.0
st2
GREATIDINING-B
c 4735
196
208
0.307
7.0.
OxO
VIFx
28.1
135.0
st2
KITCHEN
c 3695
21
162
0.375
7.0
OxO
VIFx
18.3
115.0
st1
LAUNDRY
h 844
41
21
0.366
6.0
OxO
VIFx
21.6
115.0"
st1
M. BATH
h 1162
57
54
0.366
4.0
Ox0
VIFx
21.6
115.0
st1
MASTERBEDROOM-A
h 3501
170
149
0.297
6.0
Ox0
VIFx
33.1
135.0
s112
MASTER BEDROOM-B
h 3501
170
149
0.284
6.0
OxO
VIFx
41.1
135.0
st2
wlc
c 214
4
9
0.310
4.0
OxO
VIFx
26.3
135.0
st2
Supply Trunk Detail Table
Trunk
Htg
Clg
Design
Veloc
Diam
HxW
Dud
Name
Type
(curl)
(cfm)
FR
(fpm)
(n)
(n)
Material
Trunk
st2
PeakAVF
737
724
0.284
938
12.0
0 x 0
VinlFix
st1
st1
PeakAVF
1101
1122
0.284
1050
14.0
0 x 0
MnIFlx
wrightsoft' 2019SeF170"1:11
ti ..w, w«nm...,,RJgtFSUteDUriwml20l9l9.0.07RSU09101 Page
�a rb%WdgtLwftFIVAC\WYNNE-THESTERLWGnp Ca1c=W8 FMriDaorfaces:N
Name
Grille
Size pn),
Htg
(dm)
Clg
(cfm)
TEL
(ft)
Design
FR
Neloc
(ipm)
Diam
(in)
H x W
(n)
Stud/Joist
Opening (in)
Dud
Mal
Trunk
rb1
Ox0
1160
1160
0
0
0
0
Ox 0
VIFx
C A&- wriggfiwd..• tsd! -
W < wn MgNSd" UNvereat 201919.0.07 RSWzots-sep-n osat:ll8107 Fegez
.-ea rb%WdgtWRWAQWfNNE-THESTERLNGAp UG=MJ8 FmrtDoorfaw%N