Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 - FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY �ApIfl1C® NNdd""dd��tltl�NE City, State, Zip: FT. PIERCE , FL , Owner: C( Permit Number: BY � \OC *P-N Design Location: FL, Fort Pierce b Jurisdiction: S{ LIIf:IGr niinf� County: I St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1432.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1224.00 ft2 b. Frame - Wood, Adjacent R=11.0 208.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1753.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1753.00 ft2 6. Conditioned floor area above grade (ft2) 1753 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. R= ft2 11. Ducts R ft2 7. Windows(151.4 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 265 a. U-Factor: SgI, U=1.04 111.36 ft2 SHGC: SHGC=0.29 b. U-Factor: SgI, U=1.11 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.860 ft. Area Weighted Average SHGC: 0.285 14. Hot water systems 8. Floor Types (1753.0 sgft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features EF: 0.970 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.086 Total Proposed Modified Loads: 52.74 PASS Total Baseline Loads: 53.86 1 hereby certify that the plans and specifications covered by Review of the plans and STgl� this calculation are in compliance with the Florida Energy specifications covered by this O�gBE y , _ ; O Code. calculation indicates compliance with the Florida Energy Code. PREPA D BY: Before construction is completed c O DATE: (� this building will be inspected for r� k�-� a compliance with Section 553.908 + c I hereby certify that this building, as designed '-compliance Florida Statutes. with the Florida Energy Cod COp wis OWNER/AG T: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accor��1 ����e,,yy{{ 2 A-1 1 ar►d 1W project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (1t� fflIM li6�lh3 CODE COMPLIANCE ST. LUC&E COUNTY BOCC - 9/15/2019 1:51 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 225 Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M. BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft' 0 1 0 2SIab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft' _- 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 8 It 0 56 fP __ 0 1 0 4SIab-On-Grade Edge Insulatio M. BATH 7 ft 0 61 ft' ___ 0 1 0 5 Slab -On -Grade Edge Insulatio LAUDRY t It 0 36 ft' ___ 0 1 0 9/1512019 1:51 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio BEDROOM 2 12 ft 0 180 it, _- 0 1 0 7Slab-On-Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft' ___ 0 1 0 8 Slab -On -Grade Edge Insulatio KITCHEN 11 ft 0 209 ft' ___ 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 5 ft 0 50 ft' 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft' ____ 0 1 0 11SIab-On-Grade Edge Insulatio FOYER 9 ft 0 92 ft' ___ 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft' — 0 1 0 ROOF _ / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1847 ft' 0 ft' Light N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 224 ft' 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft' 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 61 ft2 0.1 Wood 5 Under Attic (Vented) LAUDRY 30 Blown 36 ft' 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 180 ft' 0.1 Wood 7 Under Attic (Vented) DINING/GREAT 30 Blown 588 ft' 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 209 ft' 0.1 Wood 9 Under Attic (Vented) BATH 30 Blown 50 ft' 0.1 Wood 10 Under Attic (Vented) HALL 30 Blown 25 ft' 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 92 ft' 0.1 Wood 12 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft' 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w 1 NE=>W Exterior Concrete Block - Ext InEMASTER BE 4.1 16 0 8 0 128.0 ft' 0 0 0.4 0 2 SW=>E Exterior Concrete Block - Ext InAMASTER BE 4.1 7 0 8 0 56.0 ft' 0 0 0.4 0 3 NW=>S Exterior Concrete Block - Ext InEMASTER BE 4.1 14 0 8 0 112.0 ft' 0 0 0.4 0 4 NE=>W Exterior Concrete Block - Ext IndMASTER BA 4.1 8 0 8 0 64.0 ft' 0 0 0.4 0 9/15/2019 1:51 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 5 NE=>W Exterior Concrete Block - Ext InsuM. BATH 4.1 7 0 8 0 66.0 ft' 0 0 0.4 0 6 NE=>W Exterior Concrete Block - Ext InNEDROOM 2 4.1 12 0 8 0 96.0 ft' 0 0 0.4 0 7 SW=>E Exterior Concrete Block- Ext In91NING/GRE 4.1 30 0 8 0 240.0 ft' 0 0 0.4 0 8 NW=>S Exterior Concrete Block - Ext IndAINING/GRE 4.1 20 0 8 0 160.0 ft' 0 0 0.4 0 9 SW=>E Exterior Concrete Block - Ext InsuKITCHEN 4.1 11 0 8 0 88.0 ft' 0 0 0.4 0 10 NE=>W Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.4 0 11 SE=>N Exterior Concrete Block - Ext Insul FOYER 4.1 8 0 8 0 64.0 ft' 0 0 0.4 0 12 SW=>E Exterior Concrete Block - Ext Insul FOYER 4.1 1 0 8 0 8.0 ft' 0 0 0.4 0 13 NE=>W Exterior Concrete Block - Ext InEREDROOM 3 4.1 13 0 8 0 104.0 ft' 0 0 0.4 0 14 SW=>E Exterior Concrete Block - Ext InfiffDROOM 3 4.1 1 0 8 0 8.0 ft' 0 0 0.4 0 15 N=>SW Garage Frame -Wood BEDROOM 3 11 26 8 208.0 ft' 0.23 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>N Insulated FOYER None .39 3 3 6 8 21.7 ft' WINDOWS Orientation shown is the entered orientation => chan ed to Worst Case. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>S 3 Metal Low-E Single Yes 1.04 0.29 N 32.4 ft' 1 ft 0 in 1 It 5 in Drapestblinds Exterior 5 2 NE=>W 5 Metal Low-E Single Yes 1.04 0.29 N 6.9 ft' 1 ft 0 in 1 ft 5 in None None 3 NE=>W 6 Metal Low-E Single Yes 1.04 0.29 N 16.2 ft' 1 ft 0 in 1 It 5 in None None 4 SW=>E 7 Metal Low-E Single Yes 1.04 0.29 N 39.8 ft' 1 ft 0 in 1 It 5 in None None 5 NW=>S 8 Metal Low-E Single Yes 1.11 0.27 N 40.0 ft' 8 ft 0 in 1 It 5 in None None 6 NE=>W 13 Metal Low-E Single Yes 1.04 0.29 N 16.2 ft' 1 ft 0 in 1 It 5 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 806 ft2 806 ft2 26 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1168.7 64.16 120.66 .0881 5 9/15/2019 1:51 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / — Supply — — Return --- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 265 ft' Attic 55 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablre'Thermostarrt: Y Ceiling Fans: Heat ng [[ ]] Jan [X� Feb [X] Mar Apr [[[ ]] rX� € I r] Jun Jul [) Aug [[ ]] [X) Sep ] L J [[X]] Nov [[X]] Venting (1 l l Jan IIII 111 Feb IIX1l Mar May Jun ( Jul [ 1 Aug tX1 [[ 11 Sep lxl Oct [X] Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 fib 66 66 68 68 68 68 68 68 68 PM 68 68 fib 68 68 68 68 68 68 68 66 66 9/15/2019 1:51 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FOPM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft' 0 ft 0.3 BEDROOM Default(8 lbs/sq.ft. ft' ft 0.3 WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 M. BATH Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 BATH Default(8 Ibs/sq.ft. ftz ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' ft 0.3 ENTRY Default(8 lbs/sq.ft. ft' ft 0.3 LAUNDRY Default(8 lbs/sq.ft. ft' ft 0.3 GREAT/DINING Default(8 Ibs/s .ft. ft' ft 0.3 BEDROOM 3 9/15/2019 1:61 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: Jurisdiction: W Design Location: FL, Fart Pierce c=i COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ed ceiling/soffit Y /soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids beMeen Ere sprinkler cover plates anti I ceilina a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 9/15/2019 1:52 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 ' 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst rase? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1753 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.058 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.285 c) Area 7c. 151.4 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior. 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.1 14. Heating system: Capacity 34.8 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE 0 Other 15. Water heating system a) Electric resistance EF 0.97. b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF 0 Heat recovery unit HeatReC% g) Other 10B1. 11.0 10B2. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 30.0 b) Cross ventilation No 11 b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit 0 Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. o'\ Builder Signature: `Z-- Date: Address of New Home: THE WINDSOR \ t% City/FL Zip: FT. PIERCE, FL-l-A 4 U 9/15/2019 1:51:42 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Project Summary Job: wrightsoft1 rY Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fa c 772-466-6796 Email: OUICKCALCS@gOL.COM For. WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL SPA NNEQ Notes: "1e �' BY St bidprnimh, Design Information Weather. Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 18467 Btuh Ducts 6190 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Pi in Equipment load 246577 Btuh Infiltration Method Construction quality Fireplaces Fort Pierce, FL, US Simplified Average 0 Area ft z He 17n Co 1753 Volume (ftj 14741 14741 Airchanges/hour 0.38 0.20 Equiv. AVF (cfm) 93 49 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A•030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point = 34 OF 8.5 HSPF 34600 Btuh @ 47°F 27 OF 1160 cfm 0.047 cfm/Btuh 0.50 in H2O Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Summer Design Conditions Outside db 90 OF Inside db 75 OF Dailyrraign n a 1L OF Y range humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 17655 Btuh Ducts 9340 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data In Rate/swing multiplier 0.95 Equipmenf sensible load 25645 Btuh Latent Cooling Equipment Load Sizing Structure 2453 Btuh Ducts 2554 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5007 Btuh Equipment total load 306M Btuh Req. total capacity at 0.70 SHR 3.1 ton Cooling Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Cond 25HBC536W030 Coil FX4DN(B;F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual air flow 1160 cfm Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.84 REVIEWED FOR Calculations approved byACCA to meet all requiremt r@®fj( Fu�IQ� it�M {�,8/�L�N-CE wrilghtsoft' Right -Suite® Universal 201717.0.14 RSU08101 ST. LUCIE C®UN-V' Pr-101 .19ee m ...k CalcslDocuents%WYNNE-THE WINDSOR-REVISED.n1p Colo =MJ8 Front Door faces: N S®AC wrightsoft Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE Lt•L, FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: OUICKCALCS(,DAOL.COM 1 Room name Entire House MASTERBED Rco�m 153.0 it 45.0 it 3 hail 9 8.4 ft e 8.0 ft heaUood 4 P=rn dimensions x 280.0 it 5 Room area 1753.0 it' 290.0 ft-1.0 Ty Construction U-value Or HTM Area Load ea (ft Load number (Stuhlfel-F) (BtuTWft') a perimeter (it) (Btuh) or perimeter (it) (Bluh) Heat Cool Gross WPIS Heat cool Gross WPlS Heat Cod 6 13A400s 0.143 ne 4.00 2-55 488 448 1795 1141 192 192 769 489 1Aclom - 1270 : ne 35.56 70.43 7 .0 247 -_ 488 0 0 ' 0 -%Actom- . '1.270 ' ne, 35.56 : -: 70.43 16 0 - 681 .1151 "0 '0 .0 �- 0 0 _ A clom" 1.270 he 35.56 45:24 - 16 0 " 581 -739 :0 q0 .0 0 11 W �D 13AAoos 0.143 se 4.00 2.55 64 41 165 105 0 0 0 0 11DO 13A4obs _ 0.390 . 0.143 se . sw. 1092 . 400 11.31 -,.. 255 23 . 437 23 ": 396 248 15&1. 584 257 1007 0 56 6 0 . - 56 6 0 . 224 0 -> " ' 143 4A5-2cm 0.770 'sw 2156 - '' 27:53 41 45 Y140 - 0 0 13A4ocs 0.143 nw 400 2.55 290 217 867 551 112 79 318 202 I--G IAclom 1.270 my 35.56 45.24 33 0 1162 1478 33 0 1162 1478 ��----GG 4AS-2ome 0.770 nw 21.55 36.90 41 0 880 ism 0 0 0 0 12C-0sw` - 0.091 .' 2.65 128 .308 1 .. '308 - - 764 395 ' 0 '0 ' - 0 :0 C 18A30me 0.032 - 0.90 232 1753 1753 1671 4067 . . 280 .. 280 . . 251 - 650 ,F--, '22A4pl. 0.989 - 27.69: "0.00 1753 - ->153 4237: 0 280 45 1246 .. ,. .. 0 6 c)AED excursion 1360 Epp Envelope loss/gain 15594 16385 3970 3561 12 a) Infiltration 2873 810 809 228. b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Qe 230 2 460 - 0 p Appliancestother 1000 0 Subtotal nines 6 to 13) 18467 17655 4779 3789 Less exdemal load 0 0 0 0 Less transfer 0 0 0 0 Recisldbution 0 0 0 0 14 Subtotal 18460 1765 4779 3789 15 Duct loads 341. 53% 6190 9340 347.1 53% 1602 20DS Total room load 24657 26995 1 63gp 57g4 Air required(dm) 1160 1160 300 2q9 � fit- wrightsof!- Right -Suite® Universal 201717.0.14 RSU08101 ...k CaleslDocuments\WYNNE-THEWINDSOR-REVISED.mp Calc=MJ8 Front Doorfaces: 2017-Apr-10 17:19:28 Page 1 wrightsoft• Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE ILK, FT. PIERCE, FL 34946 Phone: 772-466.6799 Fax 772-0e6-6796 Emil: QUCKCALCSr1DAOL.00M 1 2 Room name Eposed wall WIC M. BATH 3 Room height0 ft 6.0 ft heaticod 7.0 ft 6.0 ft heaticad �m dimensions 7.0 x 9.0 ft 1.0 x 61.0 ft 5 - 63.0ft° 61.0 ft' TY Construction U-value Or HTM Area Load Area ft - Load number (BtuhfftMF) (Stuhlft5 a perimeter ft () (Btuh) or perimeter (ft) (Bluh) Most Cool Gross N/P/S Heat Cod Gross I WP/S Heat Cool 6 13A4ocs " 0.143 ne 400 2.55 0 0 0 r 0 66 49 196 125 -1Aclom 1.270 -ne 3556 - .70.43 0 0 0 0 7 0: 247 488 .1Aclom.: 1:270 ne " .3556 : 70.43 - 0 ' 0 o 0 0 O r 0 •:_ 1Acios 1.270: ne '35.56 ' "45.24' 0 0 0 0 0 `. " 0 17 ly �--D 13A-0acs 0.143 se 4.00 Z55 0 0 . 0 .0 0 0 0 .0 0 0 11DO -13A-0oos-- 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 WW 0.143 zsvv •4.00 +. 255' .. 0; 0 0 :0... '0: 0 .0''- -,"0 0.770 : sw'. 21:56 ' , 27.53 °- 0 0 - 0 0 0' 0 - 0 - :0 13AAccs 0.143 my 4.00 255 0 0 0 0 0 0 0 0 1A,elcm 1.270 my 35.56 45.24 0 0 0 0 0 0 0 0 `G_ 4A5-2omd 0.770 nw 21.66 36.90 0 0 0 0 0 0 0 0 P "; ;12C-0sw, 0.091 -- . 2-55 " 1:28 0 0 -0 0 0 0 -- - 0 C - 1BA30md 0.032 - 0.90 232 63 63 56 146 61 61 .. .0 55 ;" , 142 IF " 22A4pl 0.989 - 27.69 .0.00 - 63 - 0 0 0 161 . :7 - 194 0 6 c)AED mursion -5 -26 Envelope loss/gain 66 141 692 729 12 a) Infiltration 0 0 126 - 35 b) Room ventlation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 0 0 Subtotal pines 6 to 13) 56 141 817 764 Less extemal lead 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 141 874 15 Duct loads 34% 53% 19 75 34% 53% 274 404 404 Total room load 75 216 1091 1168 Air required (cfm) 4 9 51 50 Calculations approved byACCA to meet all requirements of Manual J 8th Ed ' .right.oft• 2017-Apr-1017.19:28 `p THEWINDS R-REUniveral201717. Cal RSU08101 Paget ...k CalcslDacumentslWYNNE-THE WIrmSOR-REVISED.rup CaIc=MJB From Ooor faces: N wrightsoft° Right4g) Worksheet Job: Entire House Date: QUICK CALCS, INC. By- 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-4666799 Fax 772-4666796 Emil: OUICKCALCS@AOL.COM 1 Room name LAUDRY BEDROOM 9 ed wall 0 ft 120 It 9ht 8.0 it heat/cool 8.0 0 heat/cool 4 Roomdan Ions 6.0 x 6.0 ft 15.0 x 120 ft 5 Room area 36.0 ft' 180.0 fN Ty Constwcuon U-value Or HTM Area - number (Stuhlft'°F) (Btuwft') or perimeter (ft) (Btuh) Or perimeter (ft) (Btuh) Heal I Cool Gross WP/S Heat Cool Gnus WP/S Heat Cool 6 W-13A4ocs ".. 0.143. no 4.00 . 255 - 0 0 0 0 96 80 , 319 203 tAclom 1.270 ne.' -35.56 - 70.43 - 0 - 0 - 0 0 -0'• 0,5 , 0 ..0 Uclorn -- - 1.270 ne.. � '35.56 70.43. 0 - 0 - 0 .0 .16 0 581 .' - 1151' JA-clom--- 1:270 no .35.56 - .45.24 - 0 0- 0 0 0 a 0 >. 0 11 VL-D 13A-4ocs 0.143 se 4.00 255 0 0 0 0 0 0- 0 0 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 Vy L*C 13A41acs. - .. ��4A5.2dni'.' . 0.143 �sw- 4.00 2.55 0 - 0 - 0 .0 0 0 .: 0 .: ` A 0:770 ..sw-, 21.56 .:` 27.53 . 0 ` 0 - 0 0 0 -0 . 0 ,0 13A4= 0.143 my 4.00 265 0 0 0 0 0 0 - 0 0 1Acicm 1.270 nw 35.55 45.24 0 0 0 0 0 0 0 0 �--G ` 4A5-2amd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P . ; i12C-0sW 0.091 ` .: 2.55 .1.28 . 0 0 0' . - '0,` 0 0. _'0 - - .0 C 16A41 0.032 - 0.90 232 36 36 32 84 180 180 161 418 F - '22Atpl - . 0.989 - 27.69 0.00 36 0 0 .0 .. 180 ^ 12 332 '. 0 6 c)AFD excursion S 60 Envelops lossfgain 32 81 1394 1711 12 a) infiltration 0 0 216 61 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 23D 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 32 81 16D9 1772 Less external load 0 0 0 0 Less transfer 0 p 0 0 Rerlistrib Lion 6 14 6 14 14 Subtotal 38 1541 1786 15 Duct loads 34°h 53% 13 50 34% 53% 541 90.5 Total room load 51 145 21 2730 Air required (rim) 2 8 101 01 117 117 A&A -1P1- wrightsofe- RightSuiteO Universal 201717.0.14 RSU08101 ... k CalcslDocumentslWYMJE-TFEWINDSOR-REVISED.mp Calc=MJS Front Doorfaces: 2017-Apr-10 17:19:28 Page 3 F wrightsoft• Right-M Worksheet Job: Entire House Data' QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34M Phone: 772-466.6799 Fas 772-466-6796 Email: OUICKCALCS(i)IOL.COM 1 3 4 5 Room dame Rmehde all 9 Room dimensions Room area DINING/GREAT ROOM 50.0 ft 8.9 ft heat/Cool 1.0 x 588.0 it 588.0 ft- KITCHEN 11.0 ft 8.9 It heat(cool 19.0 x 11.0 ft 209.0 ft2 Ty Construction number U-value (Btui Or HTM (Btutyft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (in w perimeter (ft) Load (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 it 13AAccs -1Ac1an -- - 1Actom: - - 1Actom: 13A4ocs 11D0 135-20m .. .13A4 n3A-0acs ' 1Ac1cm 4A54omd '12C-0sw- 16430md '22/Etpl ' - 0.143 1.270 1.270 1:270 0.143 0.390 .. 0.143 D:770 0.143 1270 0.770 0.091 0.032 0.989 ne no .- no, -'no - se se -sw 'sw nw my my - - 4.00 35.56 35.56 35.56 4,00 1092 400 21Z6 4.00 35.56 21.56 Z55 0.90 27.69 255 - 70.43 -. 70.43 45.24 255 11.31 ;.... 255 .. 27:53 255 45.24 36.90 " 1.28 232 . 0.00 0 - 0 0 0: 0 0 267, 41 178 0 41 0 688 588 0 0 0 0 0 0 . 226 - � 22 137 0 0 0 588 - 50 0 _ 0 0 0.0 0 0 ..- 903'' - 893 549 a 880 0 527 '1305 0 0 0 0 0 - '574 1140 349 0 1505 -o 1364 :' 0 - 0 0 0 0 0 0 98'. ` .0 0 0 0 ' 116 209 209 0 0 . 0 0 0 0 98. ; 0. 0 0 0. . 1 116 209 11 0 0 - .0 '0' 0 0 392 .. 0 0 0 0 ' 295 187 • 305 0 - 0 " - 0 .. 0 0 0 .i :249 .0 0 0 0 ` 148 485 0 ly �D Vy t�-CC P- C F : -: 6 c)Am mursion 1004 S4 Envelope loss/gain 5136 5937 1179 818 12 a) Vrfiltration b) Room ventilation 10DO 0 282 0 220 0 62 0 13 Internal gains: Occupants @ 230 Appliances/other 2 460 g 0 0 100 0 Subtotal (lines 6 to 13) 6136 6879 1399 1880 14 15 Less edemal load Leos transfer Redistribution Subtotal Duct loads 34% 53% 0 0 6 6142 2068 0 0 14 6693 3541 34% 63% 0 0 1399 469 0 0 1880 995 Total room Air requi�l�) �38866 1 4�40 1867 88 2875 124 Calculations approved byACCA to meet all requirements of Manual J 8th Ed h wrighttsoft- RightSuite® Universal 201717.0.14 RSU08101 2017-Apr-1017:19:28 ...k CalcslDocumentslWYNNE-THE WINDSOR-REVISED.mp .Cale =MJ8 Front Door faces: N Page wrtghtiii Right4@ Worksheet Job: Entire House Date: QUICK CALCS, INC. 9y: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: OUICKCALCSC&AOL.COM 1 Room name BATH HALL 2 Bposed wail 5.0 It 0 ft 3 Room height 8.0 It heat/cool 8.0 It heat/cool 4 Room dimensions 10.0 x 5.0 It 6.0 x 5.0 ft 5 Room area 50.0 ft' 25.0 ft' Ty Construction U-value Or HTM Area (ftq Load Area (flq Load number (BtuWfti°F) (Btulyft.) or perimeter (ft) (Btuh) or perimeter ft () (Blob) Heat Cool Gross WP/S Heat Cool Gross WPIS Heat Cool 6 13A4ocs 0.143 no 4.00 255 40 40 160 102 0 0 0 0 1Act=.. _ 1:270 - ne 35.56 - 70.43 - 0 - 0 0 0 0'- '0 '0 0 - 1Ac1om ` 1.270 he 3556 ., 70.43 - 0 - 0 0 -0 01 0 .0 �1Ac1om- 1-.270 no 35.56 - 45.24 0 0 0 0 0 . 0 0 - (i 11 Vr1 �D 13AAws 0.143 se 4.00 255 0 0 0 0 0 0 0 .. 0 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 '13A-0dcs;.. --.:.0.143 sw ,' " 4.00 , 2.55 _: -0 0' - 0 0 ..0 0 - 0 -0 4A5.26m .. ^0:770 sw 21.58 .- 2Z53 0 - 0 -0 0 0 0 , ,_ `: 0 - : 0 VI/ 13A-0acs 0.143 nw 4.00 255 0 0 0 0 0 0 0 0 1Ac1cm 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 II-----GG 4AS-2cmd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P.-'- `;12C-06W., 0.091 .': 2.55 '.1.28 0 0 0 0 - 0 0 0 `0 C. ' 16A 0.032 - 0.90 2.32 50 so 45 116 25 25 . 22 58 F. .. 22A-tpl.. tpl - 0.989 - 27.69 : 0.00 50 5 138 0 25 .0 0 '. -".0 6 c)AED excursion -8 2 Penelope loss/gain 343 210 22 58 12 a) hfiltration 90 25 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 0 0 0 0 Appliances/other 0 0 Subtotal Pines 6 to 13) 433 2351 22 56 Less eMemal load 0 0 0 0 Less transfer 0 0 0 0 Redist,:5- 6 14 -� 14 Subtotal 447 0 `K' 15 Duct loads y1o� r�o� 147 132 132 34% 53% 0 Total room load 381Air 0586 100 required (den) 28 1s 0 Calculations approved byACCA to meet all Muifements of Manual J 8th Ed wrightsoi-v 2017-Apr-10 17:19:28 �A RlghtSuite® Universal 201717.0.14 RSU08101 Page 5 ...k CalcslDoouments%WYMJE-THEWINDSOR-REVISED.mp Calc=MJ8 Front Doorfaces: N Y r O1 s 5 oc�000 oci��f .. yy gg m00043o ,ryo N 000R� PNm'� m off. N ._ E E 0 0 .� � e o 000�roNBOSOMm_o o� p 0000�$c�0000p4 N N 25 0 x LLoi ooO oa2m.O 00o2mm Ney N �.�H� F1N � ImN mN t7 0 Nnn vaN�N Nn Nua'��No �x Fl ro Q m mmmm m;'; $$2222 CCC Cmmm N^^m EEQQE ��CC Qm mm�$$��qq yy�+�?g � m I$�E E ID HIM8 Lou. ... i .. .. '.. r. .:'.{ 11 - wrightsoftDuct System Summary Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE L.K. FT. PIERCE, FL 34946 Phone: 772466-6799 F= 77246"796 Email: OUICKCALCS@AOLCOM For. WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply / return available pressure 0.250 / 0.250 in H2O 0.250 / 0.250 in H2O Lowest friction rate 0.273 in/100ft 0.273 in/100ft Actual air flow 1160 cfm 1160 cfm Total effective length (TEL) 183 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (In) H x W (In) Duct Mat[ Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 586 28 16 0.372 4.0 Ox0 VIFx 19.5 115.E st1 BEDROOM 2 D 2730 101 117 0.384 7.0 OxO VIFx 15.0 115.0 st1 BEDROOM 3 h 2697 127 100 0.353 6.0 OxO VIFx 26.8 115.0 st1 DINING/GREAT ROOM c 3411 129 147 0.292 7.0 0x0 VIFx 36.5 135.0 st2 DINING/GREATROOM$ C 3411 129 147 0.371 7.0 OxO VIFx 19.9 115.0 st1 DININGIGREATROOM o 3411 129 147 0.278 7.0 OxO VIFx 44.9 135.0 st2 FOYER h 1553 73 48 0.490 4.0 OxO VIFx 7.0 95.0 KITCHEN c 2875 88 124 0.366 6.0 ox0 VIFx 21.8 115.0 st1 LAUDRY c 145 2 6 0.371 4.0 OxO VIFx 19.9 115.0 st1 M.BATH h 1091 51 50 0.282 6.0 OxO VIFx 42.3 135.0 st2 MASTER BEDROOM h 3190 150 124 0.273 6.0 OxO VIFx 48.4 135.0 st2 MASTER BEDROOM -A h 3190 150 124 0.284 6.0 OxO VIFx 40.9 135.0 st2 WIC c 216 4 9 1 0.292 4.0 Ox0 VIFx 36.0 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (In) (In) Material Trunk st2 Peak AVF 612 602 0.273. 780 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1087 1112 0.273 796 16.0 0 x 0 VinlFlx MCA + wrilghtsoft° RlghtSuiteO Uniwmal201717.0A4 RSU08101 2017-Apr-1017:19:29 Page 1 ...k CaIcs1Documents\WYNNE-THE WINDSOR-REVISED.rup Cale =MJ6 Front Door faces: N Name Grille Size (in) Htg (cfm) Clg (cfm) I TEL (ft) Design FIR I Veloc (fpm) Diam (in) Hxw (n) Stud/Joist Opening Qn) Duct Matl Trunk rb1 Ox0 1160 1160 0 1 0 0 0 Ox 0 VIFx Fri wrightsoft` 2017-Apr-10 17:e 2 Ri9MBuite® lMrvrs xal 2017 17.0.14 RSU08707 Page 2 ... k Calcs%Documants\WYNJE-THE WINDSOR-REVISED.mp Calc = MJ8 Front Door faces: N