Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 F-LORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE MANOR 71 IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE MANOR 71 ( Permit Office: ST. LUCIE COUNTY SCANNED City, State, Zip: FT. PIERCE, FL, rC, )O Permit Number: �� Owner: WYNNE BUILDING CORP. Design Location: FL, Fort Pierce c Jurisdiction: County: St. Lucie Climate Zone`s�i} Lucie (Florida County 1. New construction or existing New (From Plans) 9. Wall Types(1654.2 sqft.) Insulation Area 2. SinEFle family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1374.20 ft' b. Frame - Wood, Adjacent R=11.0 280.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 2 d. N/A R= ft' 5. Is this a worst case? Yes 10. Ceiling Types (1724.0 sqft.) Insulation Area i a. Under Attic (Vented) R=30.0 1724.00 ft' 6. Conditioned floor area above grade (W) 1724 b. N/A R= ft' Conditioned floor area below grade (W) 0 c. R= ft z 11. Duuctct s R ft' 7. Windows(153.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 175 I a. U-Factor: Dbl, U=1.04 113.35 ft' SHGC: SHGC=0.29 b. U-Factor: Dbl, U=1.00 40.00 ft' 12. Cooling systems kBtu/hr Efficiency ! SHGC: SHGC=0.27 i a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft' SHGC:13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.51a ft. Area Weighted Average SHGC: 0.285 14. Hot water systems .� 1. , ! 6. Floor Types (1723.5 sqft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 1723.50 ft' �, b. Conservation features EF: 0.950 b. N/A R= ft. ! None c. N/A R= ft 15. Credits Pstat Total Proposed Modified Loads: 53.15 Glass/Floor Area: 0.089 PASS Total Baseline I -oads: 54.03 I hereby certify that the plans and specifications covered by Review of the plans and THE Sr this calculation are in compliance with the Florida Energy I specifications covered by this Of = s O Code. calculation indicates compliance y"o ri"' s 4 with the Florida Energy Code. _= nu,g = PREPAR D BY: Before construction is completed a DATE:-{�-r b this building will be inspected for O y I compliance with Section 553.908�� I hereby certify that this building, as designed, is in compliance Florida Statutes. el G'OD with the Florida Energy Code. _ WS OWNER' �� BUILDING OFFICIAL: DATE: F DATE:. _.. ----- - - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection ( hecklist in accordance ice. I���his project requires an envelope leakage test report with envelope leakage no greater tlan 5.00 ACH50 (Rd§. V _nE COMPLIANCE L.UCIE COUNTY ROCC 9/17/2019 3:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 FORM•R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE MANOR 71 IM Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1724 Lot # Owner Name: WYNNE BUILDING CORP. Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING CORP. Rotate Angle: 225 Street: THE MANOR 71 Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: 1 CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range i FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1724 14774.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated' 1 GREAT ROOM 546 5350.8 No 0 1 Yes Yes Yes 2 MASTER BEDROO 354 2832 No 2 1 1 Yes Yes Yes 3 WIC 77 616 No 0 1 No Yes Yes 4 CLST. 35 280 No 0 1 No Yes Yes 5 M BATH 54 432 No 0 1 Yes Yes Yes i 6 KITCHEN 180 1440 Yes 0 1 Yes Yes Yes i 7 JUNIOR M. BED 198 1584 No 0 1 1 Yes Yes Yes 8 BATH 50 400 No 0 1 No Yes Yes i 9 POWDER 35 280 No 0 1 Yes Yes Yes 10 NOOK 42 336 No 0 1 Yes Yes Yes 11 LAUNDRY 49 392 No 0 1 Yes Yes Yes 12 ENTRY 104 832 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio GREAT ROOM 47 It 0 546 ft' ____ 0 1 0 Ili 2 Slab -On -Grade Edge Insulatio MASTER BEDRO 46 ft 0 354 ft' ____ 0 1 0 $ Slab -On -Grade Edge Insulatio WIC 1 ft 0 77 ft' ___- 0 1 0 4Slab-On-Grade Edge Insulatio CLST. 1 ft 0 35 ft' ---- 0 1 0 5 Slab -On -Grade Edge Insulatio M BATH 9 ft 0 54 ft' 0 1 0 9/17/2019 3:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM•R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio KITCHEN lift 0 180 ft2 ____ 0 1 0 7 Slab -On -Grade Edge Insulatio JUNIOR M. BED 14 It 0 198 ft2 ___- 0 1 0 8 Slab -On -Grade Edge Insulatio BATH 1 ft 0 50 ft2 __-- 0 1 i 0 9 Slab -On -Grade Edge Insulatio POWDER 5 ft 0 35 ft2 -_-- 0 1 0 10SIab-On-Grade Edge Insulatio NOOK E ft 0 42 ft' ____ 0 1 0 11SIab=On-Grade Edge Insulatio LAUNDRY 17 ft 0 49 ft' ___ 0 1 0 12SIab-On-Grade Edge Insulatio ENTRY 5.9 ft 0 103.5 ft2 ___ 0 1 0 ROOF i V Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1817 ft2 0 ft2 Light N 0.6 No 0.9 No 0 18.4I AT TIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC ! I 1 Full attic Vented 300 1724 112 N N i I CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) GREAT ROOM 30 Blown 546 ft2 0.1 Wood 2 Under Attic (Vented) MASTER BEDRO 30 Blown 354 112 0.1 Wood 3 Under Attic (Vented) WIC 30 Blown 77 ft2 0.1 Wood 4 Under Attic (Vented) CLST. 30 Blown 35 ft2 0.1 Wood 5 Under Attic (Vented) M BATH 30 Blown 54 ft2 0.1 Wood 6 Under Attic (Vented) KITCHEN 30 Blown 180 ft2 0.1 Wood 7 Under Attic (Vented) JUNIOR M. BED 30 Blown 198 ft2 0.1 Wood 8 Under Attic (Vented) BATH 30 Blown 50 ft2 0.1 Wood 9 Under Attic (Vented) POWDER 30 Blown 35 ft2 0.1 Wood 10 Under Attic (Vented) NOOK 30 Blown 42 ft2 0.1 Wood 11 Under Attic (Vented) LAUNDRY 30 Blown 49112 0.1 Wood 12 Under Attic (Vented) ENTRY 30 Blown 104 ft2 0.1 WoodI WALLS \� Adjacent� r..nr r� tn�=u T.�„o Cavity Width Space @_Value Ft In Height Ft 1� Qre^ Sheathing Framing Solar R-Value Pmcticn.-.-Ahs Below 1 SW=>E Exterior Concrete Block- Ext In3HREAT ROO 4.1 26 0 9 10 255.7 ft2 0 0 0.4 0 _ 2 NNJ=>S Exterior Concrete Block - Ext InGREAT ROO 4.1 21 0 9 10 206.5 ft2 0 0 0.4 0 3 NE=>W Exterior Concrete Block- Ext InSNASTER BE 4.1 25 0 8 0 200.0 ft2 0 0 0.4 0 4 SW=>E Exterior Concrete Block- ExtInsMASTER BE 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 9/17/2019 3:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM•R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 -6 NW=>S Exterior Concrete Block - Ext InsMASTER BE 4.1 13 0 8 0 104.0 ft2 0 0 0.4 0 6 NE=>W Exterior Concrete Block - Ext InsulM BATH 4.1 9 0 8 0 72.0 ft2 0 0 0.4 0 7 SW=>E Exterior Concrete Block - Ext InsuKITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.4 0 8 NE=>W Exterior Concrete Block - Ext InslUNIOR M. B 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 _ 9 SW=>E Exterior Concrete Block- Ext InSdPOWDER 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 _10 SW=>E Exterior Concrete Block- Ext Insul NOOK 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 11 NE=>W Exterior Concrete Block - Ext InsdIAUNDRY 4.1 3 0 8 0 24.0 ft2 0 0 0.4 0 SE=>N Exterior Concrete Block - Ext InsiIIAUNDRY 4.1 7 0 8 0 56.0 ft2 0 0 0.4 0 =12 13 SW=>E Exterior Concrete Block- Ext InsdIAUNDRY 4.1 7 0 8 0 56.0 ft' 0 0 0.4 0 _14 SE=>N Exterior Concrete Block -Ext lnsul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 15 N=>SW Garage Frame - Wood ENTRY 11 35 8 280.0 ft2 0.23 0.4 0 I DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In i 1 SE=>N Insulated ENTRY None .39 3 6 8 20 ft2 WINDOVI+S -- - - Orientation shown is the entered orientation (_>) changed to Worst Case / Wall Overhang V # Orm ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SW=>E 1 Metal Low-E Double Yes 1.04 0.29 Y 46.4 ft2 1 ft 0 in 1 ft 5 in None None 2 NW=>S 2 Metal Low-E Double Yes 1 0.27 Y 40.0 ft2 10 ft 0 in 1 ft 5 in None None 3 NW=>S 5 Metal Low-E Double Yes 1.04 0.29 Y 32.4 ft2 1 ft 0 in 1 ft 5 in None None 4 • NE=>W 6 Metal Low-E Double Yes 1.04 0.29 Y 6.9 ft2 1 ft 0 in 1 ft 5 in None None 5 NE=>W 8 Metal Low-E Double Yes 1.04 0.29 Y 16.2 ft2 1 ft 0 in 1 ft 5 in None None 6 SW=>E 9 Metal Law-E Double Yes 1.04 0.29 Y 6.9 ft2 1 It 0 in 1 ft 5 in None None 7 SE=>N 12 Metal Law-E Double Yes 1.04 0.29 Y 4.7 ft2 6 ft 6 in 1 ft 5 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg Wall Height Exposed Wall Insulation 1 440 ft2 440 ft2 35 ft 8 ft 11 INFILTRATION I # Scope Method SLA CFM 50 ELA i EgLA ACH ACH 50 i j 1 Wholehouse Proposed ACH(50) .000272 1231.2 6Z59 t 127.12 .097 5 9/17/2019 3:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 4 of 6 FORM,R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr 1044 cfm 0.85 1 sys#1 i HOT WATER SYSTEM _ _ _ _ --# System Type SubType Location EF Cap Use SetPnt Conservation 1 I Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF li None None ft' DUCTS / -- Supply -- -- Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool j 1 Attic 6 175 ft- Attic 45 ft' Default Leakage Attic (Default) (Default) - 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coolin [[ ]] Heating [X] Jan [�rx],f Feb jj �Mar Jan Feb jXj Mar j jj A r [ [ j APr (]May ] Ma (X] Jun [X]]jjjj Jul [ ] Jun [ Jul r[`X Au Au[ jjXj Se j SeP [ ]] [ j Oct Oct j[ jj Nov [Xj Nov [[ ]] Dec [X] Dec Venting II 11 Jan [ ] Feb [[X]] Mar ! 1 [X]] Apr I ] May I) Jun [ ] Jul J [ Aug l [[ ] Se IXII Oct IIX1l Nov II II Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 76 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 ' Heating (WD) AM 66 66 66 65 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 _ 68 68 68 68 68 _ 68 68 66 66 9/17/2019 3:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM.R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft' 0 ft 0.3 GREAT ROOM ' Default(8 lbs/sq.ft. ft' ft 0.3 MASTER BEDROO Default(81bs/sq.ft. ft° ft 0.3 WIC Default(81bs/sq.ft. ft' ft 0.3 CLST. j Default(8 Ibs/sq.ft. ft' ft 0.3 M BATH Default(8 lbs/sq.ft. ft' ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft' ft 0.3 JUNIOR M. BED Default(8 lbs/sq.ft. ft' ft 0.3 BATH Default(8 lbs/sq.ft. ft' ft 0.3 POWDER Default(81bs/sq.ft. ft' ft 0.3 NOOK Default(81bs/sq.ft. ft' ft 0.3 LAUNDRY Default(8 Ibs/sq.ft. ft' ft 0.3 ENTRY 9/17/2019 3:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE MANOR 71 IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE MANOR 71 Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: `1 Owner: WYNNE BUILDING CORP. Jurisdiction: LL Design Location: FL, Fort Pierce c=i COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIAI I General. _— - A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. I Breaks or joints in the air barrier shall be sealer. Ceiling/attic The air barrier in any dropped ceiling/soft snail be aligned with The insulation in any dropped ceiling/soffit f the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to I unconditioned attic spaces shall be sealed. j Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity f sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed j walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights I The space between window/doorjambs and framing. and and doors l skylights and framing shall be sealed. Rim joists ' Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including I insulation. maintain permanent contact with the underside of above garage subfioor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side ; 1 floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. ! Crawl space walls ; Exposed earth in unvented crawl spaces shall be covered with Where orovided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. sha!I be permanently attached to the crawlspace g Shafts, penetrations Duct shafts, utility penetrations, and flue shafts noshing to exterior or unconditioned space shall be sealed f Batts in narrow cavities snail be cut to fit, or narrow i Narrow cavities cavities shall be filled by insulation that on E installation readily conforms to the available cavity spaces Garage separation i Air sealing shall be provided between the garage a^d conditioned spat.=_ Recessed lighting Recessed light fixtures installea in the building thermal envelope Recesseo light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring ' and plumbing in exterior walls, or insulation that on ; I installation readily conforms to available space shall l P end behind njpina and wiring Sho,,ven,, _ b I The air barrier installed at exterior walls adjacent in showers and E�t6rio' calls adjacent to Shavers and tubs shall on exterior wall iubs shall separate them from the showers and tubs. Do Insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register coots HVAC register boots that penetrate bui,d,ng taer-,al envelope shall be sealed to the sub -floor or orywau. Concealed When required to be sealed, concealed fire sprirkiers shall only be sprinklers sealed in a manner that is recommended by the ,manufacturer. Caulking or other adhesive sealants shad not oe used to fill voids hehv,EEii fr o, older coverplatas zi d wa's or reilinps, a in aoc•i.on, Inspection 01 log walls Shall be in accordance With the prov,s,ons of CC-400. 9,r17/2019 3 13 PM EnargyGauge(D USA 6.0.02 (Rev 1) - Fla Rest`)17 FBC 6th Edition (2017) Compliant Software Page 1 of 1 291'7 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX" = 98 The lower the Energy Performance Index, the more efficient the home 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Sin Ig e-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 _ 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes _ b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1724 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.030 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.285 14. Heating system: Capacity 34.8 c) Area 7c. 153.4 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) Sa. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 8.50 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) go. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1081. 11.0 2. Masonry (Insulation R-value) 1062. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 1c. d) Multizone cooling credit d) Radiant barrier installed 1d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: THE MANOR 71 C &C- City/FL Zip: r - p: FT. PIERCE. FL 9/17/2019 3:13:28 PM EnergyGauge® USA 6.0.03 (Rev 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 wrightsoft• Project Summary Entire House QUICK CALCS; INC. Job: Date: Apr 05, 2018 By. For. WYNNE BUILDING CORP. .. _ THE MANOR71 ` SCANNED Notes: U\� BY St. Lucie County Weather. Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 18275 Btuh 609 vent (0 dm) 0 �nCetrI (none) Humidification 0 Btuh Piping 0 Btuh Equipmentload 24368 Btuh infiltration Method Construction quality Fireplaces Fort Pierce, FL, US Simplified Average 0 Area (M He 1721 Co 1724 Volume (4a) 14809 14809 Airchanges/hour 0.38 0.20 Equiv. AVF(c(m) 94 49 Heating Equipment Summary Make Carrier Trade CARRIERAIRCONDITIONING Model 25HBC53GA0030 AHRI ref 3646945 Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grAb Sensible Cooling Equipment Load Sizing Structure 15981 Btuh 7860 nn Central vent (0 cfm) BluhBtu (none) Blower 0 Btuh Use manufacturer's data n' . Rate/swingg.multipplies Equipmeritsenslbleload 0.95, 22657 Btuh Latent Cooling Equipment Load Sizing Structure 2462 Btuh Ducts 2513 Btuh Central vent (0 chn) 0 Btuh (none) Equipment Went load 4975 Btuh Equipment Total Load (Sen+Lat) 27632 Bluh Req. total capacity at 0.70 SHR 2.7 ton Cooling Equipment Summary Make Carder Trade CARRIERAIR CONDITIONING Cond 25HBC536AO030 Coil FX4DNF037 AHRI ref 3645945 8.5 HSPF Efficiency 12.0 EER,15 SEER Sensible000ling 24360 Btuh 34600 Btuh@47°F Latent cooling 10440 Btuh 27 OF Total cooling 34800 Bluh 1160 cfin Actual airflow 1160 cim. 0.048 cfrnBtuh Airflowfactor 0.049 clmBtuh 0.08 in H2O Static pressure 0.08 in H2O Load sensible heat ratio 0.83 = 33°F Backup: Input= 7 kW, Output= 22529 Btuh,100 AFUE Calculations approved byACCAto meet all wrighof!' RigHSulealUtiuersal201919.0A1 RSU08101 _oftWAC\WYNNETHEM/NOR-71-1724-NONIMPACrnp Ca1c=MJ8 FmriDwrfaas N REVIEWED FOR E 2019-Apr-0313:50:19 ®CC Pace 1 Q 3 U. �jOm oo 000 oOOVIO mO - yf yto 0o yV 000N!2 �m N as 'J m m CI Ol m � 8 � m f0 m N OOO.08..O mnO aq o, �ENEI �m ot&o0000 o$oao �� p 8 m-m go in 000�mmp- �$ m$N SMe`)mmffi _ N (OO m C� OO.WP HO �.N P O O Wqg m u! Er,WP OO NWmmmCN')O RS0 aNNPN�pNN�NNNOAN' {V _ .. �r gtny qq N2`�Z22z � NonVl E^E �11 CiO^C pv� Y� ppp4��i.q.Pl ^R ^^E� onC 1�0 O W mSIrf�1�C1�91��1� p d000060000000.00 - K W K� •J3K� FT 1 .. .. .. :3 30: (Ju mS 9 R 7. m K H 00000000'OO OOO, OiO - � N OO OQN OOOb CI NW � L c '�`� o000000000000.�0 - _ � oo � 000m�� ma x } o X 0000000000 oo O, Tzo CE q o sj� g O Jm OOO OOOphp�O'O pO�mN OO{pyN M 0 N(O NV $ a .O n OOOp . ^q � W N NN m - m p X KN �000000 OOn OOONN \ O � P 00 YI v .Om OO OO OC.O OQ`N�O. G' mm N W ... 'RNN1�(iM Pj �R r'�N WPIY bO .r $NerPeB`N`�8Y�5S$$w' pNN aN ap.N N�NNN-oIY _ o00000400000000 ��r c �888 nj 33 33 0 allRIP e 11 d w '000yoyoo_000000.yyoao �c� (�� _ �O NN }a IJNa NA++a h iii t`p @ Ci `d'i [�i 6 K'i �'i o`d'i �' S x {J .. S O MzW W W+ L+o + m VI W'�O � O o �' - u000 oo 000 oo, oo o V ou000000000000a p NN 0+000 + 00 0+0000000000000 NS �P Lo a .°3 t3@'000 m 00 o .- .. on 000 oo 00000000 O - LAo 0000 W 1.i o00.000_ 0 0 � � W o wTao0 o o. 900o6o6 m� x c Ob 0000`eo oo o'oo. _ g 100 B am y p yy (m1�S000 O O+ m m W N 0+00000`,W V0000�00 cm ra O J U O w rn cl Wm 0000oo o(mpo oo 't�+y10 - - rt - .. mrn v $o 0o 1B 000ul,� uE mF tV _ 000 oo o�o go oovl�. m� ... r• o boo °� o_oo�omi m� W aOd � N m rn = O^ Z 000.000100 NO 00$rnm� - - - Oi � "CCry O OOO OO ONO[0000yy 0LD NOO OO 00000 OOO s10 '� m $j.9O w F� >< mmo 000 000 oo oo.o $� Q O (J N��Na �N�oiN �a�i..•-•-o , Fl CNNdN��ZZ.NZNxxd?N?;C,OA FS at pppp � a iod o 900000000000 � w 0 o RHO, Xt ," ig 9 iOffin �5'g0 rcC ri�oa1 �r°a �22 s� m� 14 w N Q El tl a oo 000 oo 000mo - 'y �- - Q U '�o 'J$ Imo O000000000�� - � mo n 000N' �� g41 C O �Vj % 'd'OO OO O0�0 00 OOO mN - (O e E mQ � � 000,000000O OOOVI YI ` O y$C 00000000"oo ooN �o - - "o O � N � � � L ,]v OOOOOOOOOOOOCOlNO C ' v oo v OoonQQ ,gym O 000 0 0 0 0 00 0 0 0 00 0 V N O � Q N "�,E � mQ O, O,OO OO o000000p NN , tr �V 9 MR PNNQNO'pNN�NN .CFI x �� qao 000d.o oo od000 �t E� C �@ a o N t�VN�NN1Aq�"•q�j� � '$� El a 8$�}8 8 8 N p�E�{ Q� iljj p A g 7 9 m L cm La �oo��op00000a�o vw �o oo � 000�� �� m o �I� OOO UNse Om000000(O� Q �WQ pyC�( �0000000�0O OOO nO � ,' � m r0 00 W OOOWW gt' 8 po `�y �� �000000000000m� ,. � nWo � 000�n� r� O4 X Zm �000000000000�m e N.wo0000o.o 0oo0o,Wq - 0 e e � � e�,u�N89s--o SSY3� . �p .ZZ:N�N�2 N2N N p` qq.NNqq qNq CCC ssmNGpp:a4 000000co c00000d , o He�m.� cfl 10- 3 3 ac>a u5 MZ W W 0 00$ O �NO OO V X W r O oo A O N m 0'0 0 oO V WI` , Om p. E Ooo OONW0000Oc " . RS^�W .: }� ��ppNN mm rpmm -IfM Wgv2 SIMRo utvi' 6 d R d000000000000.0o i p p Ti CC N,NA ,t/V,o E 7 of ,5 wrightsoft® Duct -System `Summary Entire House QUICK CALCS; INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:772466.6799 For. WYNNE BUILDING CORP. THE MANOR 71 NON IMPACT, FT. PIERCE, FL Job: Date: Apr 05, 2018 By: Heating Cooling Extemal static pressure 0.08 in H2O 0.08 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.08 in H2O 0.08 in H2O Supply/return available pressure 0.040/0.040 in H2O 0.040/0.040 in H2O Lowest friction rate 0.051 in/100ft -0.051 in/100ft Actual airflow 1160 ch 1160 cfm Total effective length (rEL) 156 ft Name Design (Btuh) HIg (cfm) Cig (crm) Design FR Diam pn) HxW (in) Duct Matl Actual Ln (ft) Ftgq.Egv Ln (ft) ' Trunk BATH c 201 9 10 0.074 4.0 OxO V Fx 18A 90.0 st1 CLST c 87 2 4 0.071 4.0 OxO VFx 22.5 90.0 st1 ENTRY - h 1425 68 50 -' 0.108 5.0 OxO VFx 4.0 70.0 GREATROOM h 4129 197 195 0.054 8.0 OxO VFx 37.3 110.0 st3 GREATROOWS h 4129 197 195 0.053 8.0. 0x0 VFx 39.8 - 110.0 st3 JUMORM.BED h 2381 113 111 0.070 7.0 Ox0 VFx 24.7 90.0- st1 KITCHEN c 3819 63 186 0.070 7.0 OxO :VFx 24.2 90.0 still LAUNDRY h 1889 90 43 0.078 5.0 OxO VFx 13:1 90.0 s12 M BATH h 1126 54 44 0.067 6.0 Ox 0 V Fx 29.6 90.0 st1 MASTERBEDROOM h 3138 149 134 0.054 6.0 Ox0 VFx 39.3 110.0 st3 MASTERBEDROOMA h 3138 149 134 - 0.051 6.0 OxO VFx 45.9 110.0 st3 NOOK h 657 31 16 0.082 5.0 Ox0 VFx - 7.8 90.0 st2 POWDER h 699 33 29 -0.082 5.0 Ox0 'VIFx 7.2 90.6 s2. `MC D 192 4 9 0.056 4.0 OxO V Fx 33.8 110.0 st3 Trunk Htg Cig Design Veloc Diam HxW Duct Name Type (cfm) (dm) FR (fpm) (in) (In) Material Trunk s13 PeakAVF 696 667 0.051 886 12.0 0 x 0 VnlFlx st1 ` st1 PeakAVF 938 1022 0.051 956 14.0 0 x 0 VinIFIX st2 PeakAVF 154 88 0.078 350 9.0 0 x 0 VnlFlx .� wrighttsoW 2019-Apr.0313:50:19 .� .»�+. '•+.-,cam,.. RigitSJteOLkimsa1201919.0.01RSU08101 -Paget ...aftWAQWYNNE-THEMANOR-71-1724-NONIMPACrnp Calc=MJe FWDoarfaces N Name Grille Size (in) Htg (Cfm) Clg (Cfm) TEL (II) Design FR Meloc (fpm) Diam I (in) H x W (in) Stud/Joist Opening (in) Duct I Matl Trunk rb1 NO 1160 1160 0 1 0 0 0 ox 0 1 MFx rIg^^dh w. Mg"tite®Uriwml201919.0.O1RSWP 9101 2019-Apr-031 aget Paget _ofiFNACWIYNNETFiE MANOR-71-1724NONINPALTnp 6Ic=MJ9 FroADoorfa= N -