HomeMy WebLinkAboutSHED PLANS1. BUILDING IS PLACED IN REQUESTED LOCATION ON SCHEDULE 40 PVC TO ALLOW FOR MOVEMENT TO PLUM OR SQUARE UNIT TO HOUSE, FENCE, PROPERTY LINE, ETC. 2. ONCE UNIT IS SQUARE AND THE HIGH SPOT OF THE GROUND IS ESTABLISHED, THE BUILDING IS BLOCKED ON THE HIGH SPOT AND LEVELED. THE OTHER END OF THE BUILDING IS BROUGHT UP TO LEVEL AND BLOCKED. THEN THE CENTER OF THE BUILDING 15 SUPPORTED TO LEVEL, BLOCKED, AND THEN SHIMMED. 3. AFTER THE BUILDING IS LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 4. ANCHOR PLACEMENT IS ESTABLISHED BY THE WIDTH OF THE BUILDING. HOLES ARE DRILLED THRU THE 2"x4" BOTTOM PLATE WITH A 1/2" AUGER BIT. 1/2" EYEBOLT OR OPTIONAL 1/2" THREADED ROD (FOR A "HIGH SET") IS SECURED THRU THE HOLE. 5. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. 6. IF THE UNIT HAS A FLOOR, EITHER A HOLE IS DUG FOR THE 30" AUGER ANCHOR AND BACKFILLED AND SECURED AS PER THE DETAIL OR A 1/2" HOLE IS DRILLED INTO THE CONCRETE 1-1/2 OFF OF RIM JOIST. THE -EYEBOLT IS FASTENED THRU THE BOTTOM PLATE AND A SIMPSON A-24 (OR EQUAL) IS SECURED TO THE CONCRETE WITH A 1/2" WEDGE ANCHOR. 7. IF THE UNIT IS A 'NO FLOOR' OPTION, ANCHOR WITH 1/2"x5" WEDGE ANCHOR THRU THE 2"x4" BOTTOM PLATE. TABLE 1 ANCHORING TO CONCRETE SHED WIDTH UPLIFT (PLF) ANCHOR SPACING 20'-0" 400 3'-6" 13'-B" 280 S-6" 11 •-B.. 240 S-T 200 S-6" 8'-0" 160 3'-6" 6'-0" 120 S-6" TABLE 2 SKID RUNNER SPACING - SHED WIDTH X1 X2 X3 13'-B" 1'-10}" P-104" I V-8" 2'-8" V-4" - 10'-O" V-7" 6'-10" - 8,-0" 0'-9. W-6" - 6'-0" 0'-10" 51" - NALUES ARE FROM END OF JOIST TO CENTERS OF (2) 4-.4- SKIDS ONLY. IV-8' WIDE SHEDS HAVE (4) SETS OF SKIDS. SETUP AND INSTALLATION OF DOUBLE WIDE SHED i. BUILDING IS PLACED IN REQUESTED LOCATION. THE FIRST SECTION OF THE DOUBLE WIDE IS PLACED ON THE HIGHEST LOCATION OF GROUND AND IS LEVELED UP. 2. BLOCKS ARE THEN PLACED AT THE END, CENTER, AND OTHER END TO LEVEL. ONCE THE BUILDING IS LEVEL, BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 3. THE NEXT SECTION OF THE SHED IS BACKED INTO PLACE AND UNLOADED PARALLEL WITH THE FIRST SECTION. THE TWO SECTIONS ARE CONNECTED AT THE LOWER CORNER WITH (1)1"x4�" BOLT AND NUT. THE SECOND SECTION IS THEN LEVELED AND THE OTHER BOLT HOLES ARE LINED UP AND BOLTED SECURE. THE REST OF THE BLOCKING IS THEN COMPLETED. THIS PROCEDURE IS REPEATED FOR MULTIPLE SECTION SHEDS UNTIL ALL SECTIONS ARE IN PLACE. 4. GROUND ANCHORS ARE THEN ADDED (SEE TABLE 4B). 5. ONCE THE BUILDING IS PROPERLY BLOCKED AND BOLTED TOGETHER, THE SUPPORT BRACING IS REMOVED. 6. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. TABLE 3A PAD TYPES TYPE PAD DIMENSIONS MAX. LOAD- MATERIAL I 2"xB"x16" 177SL13S CONCRETE BLOCK OUALDY CEMENT AND SAND.MIX II 4"xe"x16" 3500LBS CONCRETE BLOCK QUALTY CEMENT AND SAND, MIX III 16"x16" 3950LBS ABS PLASTIC PADS IV 8"x8"x16" 1900LBS CONCRETE BLOCK QUALITY CEMENT AND SAND MIX • BASED ON 2000PSF SOIL BEARING CAPACITY (2000PSF IS TYPICAL) NOTES 1. HOLLOW OR SOLID CONCRETE BLOCKS (8%8'xt6') MAY BE STACKED ON PADS FOR HIGH SETS UP TO 48' WITHOUT REINFORCING. 2. ASS PADS REQUIRED ON 11'-B' AND IN-S' WIDE SHEDS ONLY. TABLE 3 SUPPORT FOOTING PAD SPACING FOR RUNNER BLOCKING FOR SINGLE & DOUBLE WIDE SHEDS SHED DESCRIPTION PAD MAXIMUM LOAD AND PAD TYPE SHED WIDTH TYPE LW-(PLF) END PAD MAX. SPACING END PAD SIDE RUNNER PAD TYPE INTERIOR PAD SIDE RUNNER PAD TYPE 13'-B" SW/DW 4.15/332 Cr TO 6" 6'-0" 1936LB I, II, III, OR IV 1879LB I, II, III, OR IV 11'-8" SW/DW 6.00/480 C" TO 6" 6'-0" 2558LB I, II, III, OR IV 2558LB I, II, III, OR IV 10'-O" SW/DW 5.00/400 0" TO 6" 6'-0" 2400LB I, II, III, OR IV 2400LB I, 11, III, OR IV 8'-0" SW 4.00/320 Cr TO 6" 6'-0" 2029LB I. II, IT. OR IV 2133LB I, II, III, OR IV 6'-0' SW 3.00/240 0" TO 6" 6'-0' 1658LB I, II, III, OR TV 1866-Im I III, • LOAD WIDTH OF UPLIFT ON RUNNER NOTES 1. PAD SPACING IS END TO CENTER OF PAD. 2. PADS OTHER THAN END PADS SPACING IS CENTER TO CENTER. 3. USE SAME MAXIMUM SPACING FOR INTERIOR SPACING. RECEIVED SEP232019 S7% Luce CG , :%, Permitting S I lm=gmm GENERAL NOTES & SPECIFICATIONS FOR AUGER ANCHORS 1. BUILDING ANCHORS SHALL BE "MOBILE HOME" TYPE HP-1 SINGLE HELIX EYE AUGER ANCHOR BY HOME PRIDE OF BRISTOL, VA. OR EQUAL. AVERAGE HOLDING STRENGTH IS NOT LESS THAN 4,900 LBS. 2. ANCHORING SYSTEM TO GROUND PER LOCAL BUILDING CODE (BY DEALER). LOCATE ANCHORS PER TABLE 4A OR 4B. 3. THREADED ROD WITH EYEBOLTS SHALL BE PLACED THRU THE BOTTOM PLATE (FLOOR SYSTEM) AND ATTACHED TO ANCHOR. THESE CAN BE EXTENDED WITH THREADED ROD (OR STRAPS WITH EQUAL OR GREATER STRENGTH) FOR ELEVATED PORTIONS OF SHEDS ON LEVELING BLOCKS. TABLE 4A 30" AUGER ANCHOR SPACING - SINGLE WIDE SHED WIDTH LW UPLIFT (PLF) END ANCHOR" MAX. INTERIOR SPACING••• 13'-B" 7.00 243 C'-0" TO S-C 10'-0" i l'-8" 6.00 208 10'-O" f 10'-0" 5A0� T74� 0-0, •5-0� L` 10'. 0"1 _ 8'-0" 4.00 138 S-T TO S-e 10'-0" 6'-0" 3.00 104 0'-0' TO 3'-0" 10'-0" TABLE B 30" AUGER ANCHOR SPACING - DOUBLE WIDE SHED WIDTH LW UPLIFT (PLF) END ANCHOR-- MAX. INTERIOR SPACING... 20'-0' 10.00 400 0'-0" TO 3'-0" 1 5'-0' • LOAD WIDTH OF UPUFT ON RUNNER •• LOCATION FROM END WALL OF AUGER ANCHOR ••• MAXIMUM SPACING BETWEEN ANCHORS NOTES _ 1. ANCHOR SPACINGS DESIGNED AS PER ASCE. 2. ALL MEASUREMENTS ARE CENTERS PECENTER. % 3. THE MINIMUM NUMBER OF ANCHORS PER SHEDREQUIRED IS (4). IN ANCHOR PER EACH CORNER. AETWEENAL CHFRIOR ANCHORS ARE REpU1RED IF SPACING IS MORE THAN 10'-0' py BETWEEN ANCHORS.. 4. ANCHORS SHALL BE ON SIDE WALLS EXCEPT WHEN THE SHED IS PLACED NEXT TO OSDNG BUILDING; WHICH ANCHORS CAN BE PLACED ON THE END WALLS CLOSE AS CLOSE T TO THE SIDE AS POSS SIBLE. SCA/�,N N- 1 a W • 2'x2" GALVANIZED WASHER ® 2"x2' GALVANIZED WASHER WITH 1/2- NUT 1/2- THREADED ROD "HIGH `fit• Lucie c 11y� _ ffjl n._ i WITH 1/2' NUT I� OPTIONAL FOR SET* NOTCH OR COUNTERSINK BOLT 1/2- THREADED ROD EYES BOLTED TOGEMER WITH 1/2'x2' THRU 2"x4" 8070M PLATE OPTIONAL FOR 'HIGH SET" BOLT & NUT WITH (2)2"xY GALVANIZED 1/2" COUPLER 2N4' BOTTOM PLATE NAILED _ 1/2' COUPLER - _I �� 1 /2'x12" FORGED EYEBOLT WASHERS (2.ODOLB SHEAR CAPACITY) _ )( _ MIN. ° - a 1/2'x5' (400 OR CONCRETE WEDGE ANCHOR INTO SLAB-------- 2'xA' P.T. BOTTOM PLATE THRUJ TO 2'x6' P.T. BASE 4' MIN. _ n (SEE TABLE 1 FOR SPADING) 16------- (S -a------- EYES BOLTED TOGETHER WITH 1/2� E I, II, III, OR IV PAD WITH BOLT & NUT WITH (2)2'x2' GALVANIZED 9 ttIL 1/2"x3" (400 UL SIMPSON A-24 CONCRETE SLAB BY OTHERS THROUGH CONCRETE SLAB BY OTHERS THROUGH 5 CKING AS REQUIRED (SEE TABLE 3). WASHERS (2.DOOlB SHEAR C AQf1Y}� CONCRETE WEDGE ANCHOR CUP OR EQUAL LOCAL CODES AND JURISDICTION LOCAL COPES AND JURISDICTION (SEE TABLE 1 FOR SPACING) 30' EARTH AUGER CHOP (SEE TABLE a roR SPacING) SHED WITH SKID SHED WITH 'NO FLOOR' OPTION gg0�SHED WII IH SKID vTO�PADiOR><BLLOCKING _ ANCHORED TO CONCRETE ANCHORED TO CONCRETE TIE -DOWN DETAILS CODE VERSION MC 2017 M EJIPo". ISLE-7 MANUFACTURER SURMOR BHEOS BUILDING TYPE OF REO BUIIDI G RESNENML LAWN STOMGE CONSTRUCTION TYPE V-B FIRE PROTECTION NONE FIRE SUPP_RES510N SYSTEM_ _ _ - NONE - OCCUPANCY STORAGE ALLOWABLE NUMBER OF STORIES I BASIC WIND SPEED V­200,h EXPOSURE D ENCLOSURE ENCLOSED INTERNAL PRESSURE COEFFICIENT IMPORTANCE FACTOR 1.15 ROOF DEAD IAAD IOPSF ROOF LIVE LOAD 2XMF OR 301)1 a FLOOR DEAD LOAD 8PSF FLOOR UVE LOAD SIO. 75PEF - M2 OPT. 'R' RATING OF WALLS. FLOOR. ROOF N/A MODULES PER BUILDING I HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SOUARE FOOTAGE . THMI . 50JT. t 2017 FBC H/IV17 Nt8 2 G: ANCHOR V AF.G NAY. ANCHOR EXR54SON 5/26/le NIB (n LLJ (n LLJ 0 L1J J m D 0 Nl LLJ J 0 Z vT I LLJ 0 1. FOUNDATION PLANS ARE NOT PART OF THIS PLAN SET AND ARE GOVERNED BY LOCAL JURISDICTION. 2. THIS BUILDING IS EXEMPT FROM THE MC ENERGY CONSERVATION CODE PER SECTION 3. REFER TO PE -DOWN DETAILS FOR PROPER INSTALLATION REQUIREMENTS TO MEET CODE. 6/1/18 2018-12-20� ':'LINE ENGINEERING APPROVAL •lN #SS-B-180-C 4iUMINUM ROOF SHEATHING Side Wall Header Schedule (180C) End Wall Header S Building Width •Did) Maz. Span NJ@} Size Up to 14' Wide Fasteners w/ strap L2'x4' E-0' D nnw a...., a Imr (each entl) 22'x4'(c11 11,1 Won M a I O tz RUNNERS I END WA.. TRUSS 2 W TRUSS 0 24" O.C. MAX UP IGN PRESSURES ROOF +27.8 -94.7 AL1S/OOOR5 ND +32.6 -29.2 ROOF FRAMING PLAN ELEVATION CROSS—SECTION TYPICAL ARCH FRAME jT.B a l TAT' END ELEVATION WRH GARAGE DOOR (ollr di OoIYNU laoounea wines are ror rva L grace apluce-rifle+n lum W - Number of jack studs required to support each end. Laid flat NJ- Number ofjack studs required to support each end. Window header for window openings that hale more than 500A combined stud wall abole •� id below, otherwise use door header schedule. See header details for alternate layouts, i.e. 2-2'x4 or 4-x4' P.T.Hoaxes 1. saE lr m wawE me Iw¢WNS n ,s,E,!,�°� swamlc ror AomwNti L muies The header can be attached to the top plate and thus have the combined strength 7io mibA'allmys mrmIudwancellcem� s Willem and use the maximum span stated. Xwc ST05 J mlmw EVkp 2-x{• l i (2)2-a{ wTIH 1/Y RYIkW aessa n u I aR (IY-N- I I e I i 1111Y at 19-W sowsEN 1 I wMl STA1S eF11I 6 SEPIWD -�As�h12' MAX ' HYDROVENT DETAIL SIDE WALL WINDOWS END WALLS WINDOWS & k0Pj1Q-NALj & DOORS DOOR 6' WIDE OR LESS �+ G.F.I. NOTEs-oPnoNu ELECIRIc OUTLET NQo -ALL WIRING SHALL BE 14 GALE 3-WRE MC CABLE. -ENCASE IN ALL METAL BOXES. SOURCE L WIRING DIAGRAM (OPTIONAL) z sin 2r ac 4"x4" W/2"x4" NLr'-ZTC:', t W Illam E. Naa,, In SNIP-51, SPAI-99, ICC 5185040 I W9oSm.x P.nda re:razc GouFa, Tlan.b 34711 eeu In R awx 11-1112' s7RAP w/a-toa Awls STANDARD WALL DETAIL Nore wul DCAWIw Mllleoa AaE cWdnLars rzau Pt mu4 nnm vo-•/mmlc WrrH DOOR & WINDOW OPTIONS NAIMTpN su ro Pow N0 2ivRm 10 Oars A aY11VaNT5 Ibra PUB wluf¢WNi YDEma Aff _ RTppo Nor nA vuE TFS Oi CIIDs K mein SW c 9Yll BE n]dlm OF fJLYUI® SIFIl OF MDT IE4 - ]/{- P.T. FLYTM1UD W - ]/4-_ T. . . TxW o.da' IWVUI TaoWfs. - ]/! P.T. T. 4 Wl ____ ____ ____ ____ _ ___ T ABLE son 2 9m oM xi aa aa u'-e• r-Iq• 1•-11N' I•--er 11'-B Yd FN' W-e. L'-T f-W a-d - m I �A><.W apa�ro0lwvy{V O I I 4 I I I I uh j L8 P.T. 2{• o.G TYP. 'F I CPIICkY 13/ *T O 16- ex. I I T19 . wIM J/{' Tee RYB6YNe 0 {'M' P.T. ATIWIm Mnl N2{ ca Ee s¢ a Qu*(. 2 TOR aANmr Rio i sPArar4 Sege i I ___ L.Ravl aoar. s¢ sn¢azE Tin saE nLRnur.z,L�Ru. swmaR s14ns 9URDING TYPE IL9aF11111L soRwx WNSTRUCTON TYPE Y-a ORE PROTECTION NONE ME SUPPRESSION SYSTEM hollc- cxxU NCY sn"AcE ALIOwABLE NUMBER OF WORM I BASIC wn1D EEO N—I. INTERNAL PRESSURE MEFR )ENT a/- ala IMPORTANCE FACTOR 1.15 ROOF DEAD LOAD 10Pi ROOF WE UMD 30Ps m aove Pow . BOOR DEAD LOAD 10PSF FLOOR LIVE LAND 514 i5P3 - I2 aPT. W RATING OF WALLS. FLDOR ROOF N/A MEuus PER BUUWNG I SHELTER REVISIONS SaE. on na W MTB Z Date: J 12/12/17 z O.-. swx: (n r N/A 1++ cdel Z !n SS-B-180C W I. RUNvuNs uE Nor Pun rc Tws PVN SET sN0 ARE 0- Wo7ATMm In -R Ju�M.7W1 2 110 BNIOT n FxdlPr miUl nIE mC Er1TA4Y mMWiATRN W J woE Rm _oppNy,�t�m5n. 1 I�1wbR�5R 4FEilaFewPR64A WsrNlAtloN O{.m �sNB. IW1nS. nN55LC EIG I.ff M 12 sPF. Ex®r U 4 srtax7wns wrs {co sa m. wu NINE AN eo' MaIIYW OWR Wrr4lffi To ff WsrI WEFT 9Y IkMVL TRII Iofl1 NQ 7. .1LL IhNmlI5 u1a dxlt5 TO MriT TIE WMMW SPEOfIGnMiS W o As Pm�rluaU� w a.iRn cmu..mu V.u— CL ,j' L\CENSe ••'• ���� Ld -;53 i• STATE 0 OF O '''', �0 0 Matthew T. Baldwin P.E. z Florida License #64608 m Sheet SSB-1 OF 1