Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
2017 EPL DISPLAY CARD SCANNED BY Ct• Lucie County 0 s� o� ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CA13'b ,p1.b° ESTIMATED ENERGY PERFORMANCE INDEX* = 77 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R - 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location AC 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 0 13. Cooling system: Capacity 40.0 a) Split system SEER 16.0 5. Is this a worst rase? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1294 d) Room unit/PTAC EER e) Other 7. Windows, type and area a)'U-facton(weighted average) 7a. 0.400 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 40.0 c) Area 7c. 215.8 a) Split system heat pump HSPF 9.0 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(welghted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior. 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.0 15. Water heating system a) Electric resistance EF 0.96 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ 0 Heat recovery unit HeatRec% g) Other 10131. 13.0 10B2. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 30.0 b) Cross ventilation No 11b. c) Whole house fan No 11c, d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat No 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: -7 Address of New Home: Clyde Mitchell Jr. Residence City/FL Zip: Ft Pierce, FL 34982 613/2019 1:31:32 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Clyde Mitchell Jr Builder Name: Maurice Shazier Street: Clyde Mitchell Jr. Residence Permit Office: City, State, Zip: Ft Pierce , FL, 34982 Permit Number: Owner: Clyde Mitchell Jr Jurisdiction: 661100 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1491.4 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.0 1338.40 ft2 b. Frame - Wood, Adjacent R=13.0 153.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 0 d. NIA R= ft2 5. Is this a worst case? No 10. Ceiling Types (1294.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1294.00 ft2 6. Conditioned floor area above grade (ft2) 1294 b. NIA R= ft' Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Wmdows(215.8 sgfQ Description Area a. Sup: Attic, Ret: FOYER, AH: AC 6 516 a. U-Factor: Dbl, U=0.40 215.75 ft2 SHGC: SHGC=0.25 b. U-Factor. N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 40.0 SEER:16.00 c. U-Factor: NIA ft2 SHGC: 13. Healing systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Heal Pump 40.0 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems 8. Floor Types (1292.8 sgft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 1292.80 ft' b. Conservation features EF: 0.960 b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.167 Total Proposed Modified Loads: 33.10 PASS SS Total Baseline Loads: 43.24 r /'� 1 hereby certify that the plans and specifications covered by Review of the plans and S7,1j� this calculation are in compliance with the Florida Energy specifications covered by this o�•IIIE Code. calculation indicates compliance /7 n ��� / PREPARED BY: �/� C� �2 with the Florida Energy Code. Before construction is I. nn„".: •;;_' `. ` „ �O completed DATE: June 3rd 2019 this building will be inspected for compliance with Section 553.908 a I hereby certify that this building, as designed, is in compliance Florida Statutes. C with the Florida Energy Code. COP WETF� OWNER/AGEN BUILDING OFFICIAL: DATE: �� ? DATE: / - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 613/2019 1:30 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Clyde Mitchell Jr Bedrooms: 0 Address Type: Street Address Building Type: User Conditioned Area: 1294 Lot # Owner Name: Clyde Mitchell Jr Total Stories: 1 Block/Subdivision: ' # of Units: 1 Worst Case: No PlatBook: Builder Name: Maurice Shazier Rotate Angle: 0 Street: Clyde Mitchell Jr. Read Permit Office: Cross Ventilation: No County: St. Lucie . Jurisdiction: 661100 Whole House Fan: No City, State, Zip: Ft Pierce , Family Type: Single-family FL, 34982 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Entire House 1294 11508 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 DINING 86 731 No 0 1 Yes Yes Yes 2 KITCHEN 142 1205 No 0 1 Yes Yes Yes 3 GREAT ROOM 201 1910 No 0 1 Yes Yes Yes 4 W I C a 18 153 No 0 r 1 No Yes Yes 5 MAST BEDROOM 188 1600 No 2 1 Yes Yes Yes 6 W I C b 27 230 No 0 1 Yes Yes Yes 7 MAST BATH 96 815 No 0 1 Yes Yes Yes 8 BATH 41 349 No 0 1 No Yes Yes 9 CL 4 30 No 0 1 No Yes Yes 10 HALL 31 266 No 0 1 No Yes Yes 11 FOYER 56 782 No 0 1 Yes Yes Yes 12 BEDROOM 2 149 1265 No 1 1 Yes Yes Yes 13 CL2 23 191 No 0 1 Yes Yes Yes 14 AC 10 82 No 0 1 Yes Yes Yes 15 LAUNDRY 51 435 No 0 1 Yes Yes Yes 16 CL3 17 148 No 0 1 Yes Yes Yes 17 BEDROOM 3 154 1305 No 1 1 Yes Yes Yes 61312019 1:30 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 1 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio DINING 19.5 ft 0 86.1 ft2 __ 0 0 1 2SIab-On-Grade Edge Insulatio KITCHEN 11.3 ft 0 141.8 ft2 __ 0 0 1 3 Slab -On -Grade Edge Insulatio GREAT ROOM 13.5 ft 0 201 ft2 ___ 0 0 1 4 Slab -On -Grade Edge Insulatio W I C a 1 ft 0 18 ft2 0 0 1 5 Slab -On -Grade Edge Insulatio MAST BEDROO 30.8 ft 0 188.3 ft2 __ 0 0 1 6 Slab -On -Grade Edge Insulatio W I C b 4.5 ft 0 27 ft2 0 0 1 7 Slab -On -Grade Edge Insulatio MAST BATH 6.5 ft 0 95.9 ft2 0 0 1 8 Slab -On -Grade Edge Insulatio BATH 1 ft 0 41 ft2 — 0 0 1 9 Slab -On -Grade Edge Insulatio CL 1 It 0 3.5 ft2 R 0 0 1 10Slab-On-Grade Edge Insulatio HALL 1 It 0 31.3 ft2 __ 0 0 1 11SIab-On-Grade Edge Insulatio FOYER 6.8 It 0 55.9 ft2 0 0 1 12SIab-On-Grade Edge Insulatio BEDROOM 2 12.3 It 0 148.8 ft2 __ 0 0 1 13SIab-On-Grade Edge Insulatio CL2 1 ft 0 22.5 ft2 __ 0 0 1 14SIab-On-Grade Edge Insulatio AC 3.5 It 0 9.6 ft2 __ 0 0 1 15SIab-On-Grade Edge Insulatio LAUNDRY 8.5 it 0 51.1 ft2 0 0 1 16SIab-On-Grade Edge Insulatio CL 3 2.3 It 0 17.4 ft2 0 0 1 17SIab-On-Grade Edge Insulatio BEDROOM 3 32.3 ft 0 153.6 ft2 __ 0 0 1 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1363 ft2 0 ft2 Medium N 0.85 No 0.9 No 0 18A ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1293 ft2 N N 613/2019 1:30 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type _ 1 Under Attic (Vented) DINING 30 Blown 86 ft' 0.1 Wood 2 Under Attic (Vented) KITCHEN 30 Blown 142 i' 0.1 Wood _ 3 Under Attic (Vented) GREAT ROOM 30 Blown 201 ft' 0.1 Wood 4 Under Attic (Vented) W I C a 30 Blown 18 ft2 0.1 Wood 5 Under Attic (Vented) MAST BEDROO 30 Blown 188 ft2 0.1 Wood 6 Under Attic (Vented) W I C b 30 Blown 27 ft' 0.1 Wood 7 Under Attic (Vented) MAST BATH 30 Blown 96 ft2 0.1 Wood _ 8 Under Attic(Vented) BATH 30 Blown 41 ft' 0.1 Wood 9 Under Attic (Vented) CL 30 Blown 4ft2 0.1 Wood 10 Under Attic (Vented) HALL 30 Blown 31 ft2 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 56 ft2 0.1 Wood 12 Under Attic (Vented) BEDROOM 30 Blown 149 ft2 0.1 Wood 13 Under Attic (Vented) CL2 30 Blown 23 ft2 0.1 Wood 14 Under Attic (Vented) AC 30 Blown 10 ft' 0.1 Wood 15 Under Attic (Vented) LAUNDRY 30 Blown 51 ft2 0.1 Wood 16 Under Attic (Vented) CL 3 30 Blown 17 ft2 0.1 Wood 17 Under Attic (Vented) BEDROOM 3 30 Blown 154 ft2 0.1 Wood WALLS Adjacent S Cavity P ace Width Height Sheathing Framing Solar Below e=ype o v i F1 i Et In n R Value Fr,",,Fr,",,n Ahso1w3de°J _ 1 N Exterior Concrete Block - Ext Insul DINING 4 12 9 8 6 108.4 ft' 0 0 0.3 0 _ 2 W Exterior Concrete Block- Ext Insul DINING 4 6 9 8 6 57.4 ft' 0 0.23 0.3 0 _ 3 W Exterior Concrete Block -Ext InsuKITCHEN 4 11 3 8 6 95.6 ft' 0 0.23 0.3 0 -4 N Exterior Concrete Block- Ext InGREAT ROO 4 13 6 9 6 128.3 ft' 0 0.23 0.3 0 _ 5 N Exterior Concrete Block- Ext In9MAST BEDR 4 13 6 8 6 114.8 ft' 0 0.23 0.3 0 _ 6 E Exterior Concrete Block- Ext InNAST BEDR 4 13 6 8 6 114.8 ft' 0 0.23 0.3 0 _ 7 W Exterior Concrete Block- Ext InsMAST BEDR 4 3 9 8 6 31.9 ft' 0 0.23 0.3 0 _ 8 E Exterior Concrete Block - Ext Insul W I C b 4 4 6 8 6 38.3 ft' 0 0.23 0.3 0 _ 9 E Exterior Concrete Block - Ext InsWST BATH 4 6 6 8 6 55.3 ft2 0 0.23 0.3 0 10 S Exterior Concrete Block- Ext Insul FOYER 4 6 9 14 0 94.5 ft' 0 0.23 0.3 0 _ 11 E Exterior Concrete Block - Ext InREDROOM 2 4 12 3 8 6 104.1 ft2 0 0.23 0.3 0 _ 12 S Garage Frame - Wood BEDROOM 2 13 11 9 8 6 99.9 ft2 0 0.23 0.3 0 _ 13 S Garage Frame - Wood CL2 13 2 6 8 6 21.3 112 0 0.23 0.3 0 _ 14 W Exterior Concrete Block- Ext Insul AC 4 3 6 8 6 29.8 112 0 0.23 0.3 0 15 S Exterior Concrete Block - Ext lnsdlAUNDRY 4 3 0 8 6 25.5 ft2 0 0.23 0.3 0 _ 16 W Exterior Concrete Block - Ext InsdIAUNDRY 4 5 6 8 6 46.8 ft2 0 0.23 0.3 0 17 S Garage Frame - Wood LAUNDRY 13 3 9 8 6 31.9 ft2 0 0.23 0.3 0 _ 18 W Exterior Concrete Block - Ext Insul CL 3 4 2 3 8 6 19.1 ft2 0 0.23 0.3 0 _ 19 E Exterior Concrete Block - Ext InfiEDROOM 3 4 8 3 8 6 70.1 ft2 0 0.23 0.3 0 20 S Exterior Concrete Block - Ext InERffDROOM 3 4 12 0 8 6 102.0 ft2 0 0.23 0.3 0 21 W Exterior Concrete Block - Ext InfiffDROOM 3 4 12 0 8 6 102.0 ft' 0 0 0.3 0 6/3/2019 1:30 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 S Wood FOYER None .56 4 9 7 33.3 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. . _ / V # Wall Omt ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation Int Shade Screening 1 2 3 4 5 6 7 8 9 10 N 1 Metal W 2 Metal N 4 Metal N 5 Metal E 6 Metal E 9 Metal S 10 Metal S 10 Metal E 11 Metal S 20 Metal Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes 0.4 0.25 N 0.4 0.25 N 0.4 0.25 N 0.4 0.25 N 0.4 0.25 N 0.4 0.25 N 0.4 0.26 N 0.4 0.25 N 0.4 0.25 N 0.4 0.25 N 15.0 ft2 2 ft 0 in 1 ft 0 in 22.5 ft2 2 ft 0 in 1 ft 0 in 30.0 ft2 2 it 0 in 1 ft 0 in 31.3 ft2 2 ft 0 in 1 ft 0 in 30.0 ft2 2 ft 0 in 1 ft 0 in 15.0 ft2 2 ft 0 in 1 it 0 in 4.5 ft2 2 ft 0 in 1 ft 0 in 15.0 ft2 2 ft 0 in 1 ft 0 in 22.5 ft2 2 ft 0 in 1 ft 0 in 30.0 ft2 2 ft 0 in 1 8 0 in Drapes/blinds Drapes/blinds Drapes/blinds Drapeslblinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Exterior 5 Exterior 5 Exterior 5 Exterior 5 Exterior 5 Exterior 5 Exterior 5 Exterior 5 Exterior 5 Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 440.9375 ft2 440.9375 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Whclehouse Proposed ACH(50) .000395 1341.3 73.64 138.48 .1428 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:9 40 kBtu/hr 1 sys#1 _ COOLING SYSTEM NZ # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 40 kBtu/hr cfm 0.71 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Attic 0.96 50 gal 62.3 gal 120 deg None 613/2019 1:30 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS ' _ / —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 516 ft2 FOYER 16 ft2 Default Leakage AC (Default) (Default) 1 1 TEMPERATURES Programablre Thermostaf[t: N CeFans: Heating Jan Feb Mar Apriling (�XC Jun (i Jul ]] r1 Aug IX t Sep rI)C') Dec Venting [ Jan ( Feb l l l l X Mar Apr [ MMay ay lXl Jun [( Jul Aug ( Sep Oct [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 0 ft 0.3 DINING Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 GREAT ROOM Default(8 Ibsisq.ft. ft2 ft 0.3 WIC a Default(8 Ibs/sq.ft. ft2 ft 0.3 MAST BEDROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC b Default(8 Ibs/sq.ft. ft2 ft 0.3 MAST BATH Default(8 lbs/sq.ft. ft2 ft 0.3 BATH Default(8 lbs/sq.ft. ft2 ft 0.3 CL Default(8 lbs/sq.ft. ft2 ft 0.3 HALL Default(8 lbs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft2 ft 0.3 CL2 Default(8 lbs/sq.ft. ft2 ft 0.3 AC Default(8 lbs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 lbs/sq.ft. ft2 ft 0.3 CL3 Default(8 Ibs/s .ft. ft2 ft 0.3 BEDROOM 3 613/2019 1:30 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 Load Short Form Job: Clyde Mitchell Jr. Pesldence, Wrightsofte Date: Jun 03,2019 Entire House By. Kenneth D. Ptcdnas WebREPS, LLC 188082nd Aeue SuIW203.19mBeadl,FL3296BPhone:B00810.32B0 Fax B88-971-2999 Em l:rrenuaLl@mbrep9tm=mNbb:~AcducWedgnmmUmnw:C00054709 For. Maurice E., Shazier SCANNED 800 VirginiaAvenue Suite 59-13, Fort Pierce, FL34982 �� Phone: 954-649-7269 Email-maurice@repshvac.com �gf• Lucie CountY Htg . Clg Infiltration Outside db (°F) 43 91 Method Simplified Inside db (°F) 70 75 Construction quality Tight Design TD (°F) 27 16 Fireplaces Daily range - L Inside humidity (%) 30 50 Moisture difference.(gr/lb) 0 59 HEATING EQUIPMENT Make Goodman Mfg. Trade GOODMAN Model GSZ160421B AHRI ref 201675992 Efficiency , Heating input Heating output Temperature rise Actual airflow Airflowfaclor Static pressure Space thermostat Capacity balance point =27 OF 9 HSPF 41000 Btuh@47°F 28 OF 1393 rim 0.067 dmBtuh 0.60 in H2O Backup: Input=7kW- Output=2427413tuh.100AFUE COOLING EQUIPMENT Make Goodman Mfg. Trade GOODMAN Cond GSZ160421B Coil . ASPT49D14A AHRI ref - 201675992 Efficiency 13.0 EER, Sensible 000ling Latentcooling Total cooling Actual airflow Airflowfactor Staticpressure Load sensible heat ratio 16 SEER 28400 Btuh 11600 Btuh 40000 Btuh 1333 rim 0.054 dm/Bh1h 0.60 in H2O 0.71 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) HtgAVF (rim) ClgAVF (rim) DINING 86 2417 4105 161 221 KITCHEN 142 1408 3548 94 191 GREAT ROOM 201 1963 3363 131 181 WICa 18 0 0 0 0 MAST BEDROOM 188 3901 4129 260 223 W I C b 27 486 212 32 11 MAST BATH 96 916 1013 61 55 BATH 41 62 127 4 7 CL 4 0 0 0 0 HALL 31 0 0 0 0 FOYER 56 1680 1392 112 75 BEDROOM 2 149 1640 2537 109 137 CI-2 23 0 0 0 0 wr in n n n n Calculations approved byACCA to meetall requirements ofManual J 8th Ed. wrlghtsaf * Rgh4SuileGUn!WM]201919.0.13RSU16998 ACCA _Custom ConaemiSharieoNClyde Mtrhell Jrrup Cale=MlB Front Doorfaces S 2019-Now20159723 Page 1 LHUINUKT CL 3 BEDROOM 3 al 17 154 toga 0 3852 7r-Itl 0 2581 IIU 0 257 Ua 0 139 Entire House 1293 19967 24724 1333 1333 Other equip loads 2041 2878 Equip. @ 1.00 RSM 27602 Latent000ling 11393 7n1 Al C 11131 0nnn7 900O1Z 1't1'a 110'a Calculations approved byACCA to meet all requirements of Manual J 8th Ed. Wrlghtsoft- 2019-Nor20151723 RIgh4SuRe®Univeml 201919.0.13 RSU16998 Page ACM _Cu wmCon=W(Shaaer)XQydetAthell J' p Cale=NUB Fronl Doortdces. S Project Summary Job: Clyde Mitchell Jr. Residence ProDate: JunO3,2019 wrightsofto Ent re House By: Kenneth R Puldws WebREPS, LLC 188082nd Aeue Suite 203,Varo Beady FL 32966 Phone:800-8103280 Faz888-971-2999 Email: mnuaUt1,mbmpshw=m"bb:w ..acdutldesgn=m Lloanse: CO0054709 Prooect Information For. Maurice E., Shazier 800 Virginia Avenue Suite 59-B, Fort Pierce, FL34982 Phone: 954-649-7269 Email: maudoe@repshvaacom Notes: Clyde Mitchell Jr. Residence, Ft Pierce, Florida Weather. Ft Pierce, FL, US Winter Design Conditions Summer Design Conditions Outsidedb 43 OF Outsidedb 91 OF Insidedb 70 OF Insidedb 75 OF Design TO 27 OF Design TO 16 OF Daily range L Relative humidity 50 % Moisture difference 59 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 14885 Btuh Structure 17272 Btuh Duds 5082 Btuh Ducts 7452 Btuh Central vent (69 cfm) 2041 Btuh Central vent (69 cfm) 1171 Btuh Outside air Outside air Humidification 0 Btuh Blower 1707 Btrhh Piping 0 Btuh Equipmentload 22007 Btuh Use manufacturer's data y Rate/swingg multiplier Equipmerltload 1.00 27602 Btuh Infiltration sensible Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 0 Structure 6539 Btuh Duds 2081 Btuh Central vent (69 cfm) 2773 Bbhh Heatirnx�g Coolinngg Outside air Area(ft') 1293 1293 Equipment latent load 11393 Btuh Volume (n 11496 11496 Airchanges(hour 0.16 0.08 Equipment Total Load (Sen+Lat) 38995 Btuh Equiv.AVF(dm) 31 15 Req. total capacity at 0.71 SHR 3.2 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN Trade GOODMAN Model GSZ160421B Cond GSZ160421B AHRlref 201675992 Coil ASPT49D14A AHRI ref 201675992 Eftidency 9HSPF Efficiency 13.0 EER, 16 SEER Heating input Sensible cooling 28400 Btuh Heating output 41000 Btuh @ 47°F Latent000ling 11600 Btuh Temperature rise- 28 OF Total Cooling 40000 Btuh Actual airflow 1333 ctrn Actual airflow 1333 dm Airflowfector 0.067 dmBtuh Airflowfador 0.054 cfm/Btuh Static pressure 0.60 in H2O Static pressure 0.60 in H2O Space thermostat Load sensible heat ratio 0.71 Capacity balance point = 27 OF Backup: Input=7kW,, Output= 24274 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed +. _ w_rlghisofC' 2019-Nor2015:37:23 Ngh4Suile®Univ =1201919.0.13 RSU16998 Page l ��t, .-Custom Conoete(Shaner)K2ydeh51rhell Jrt p Cale-KIS FronlDoorfaoes S is Sheet 1 GREAT ROOM 6x6 111 cfm 5" DINING 6x6 7„ 181 cfm 5„ 10" 6x6 111 cfm KITCHEN 20xl2 838drn 6x6 6x6 7" 7cfm 191 cfm 16" 12x12 \� 129cfm 6\ FOYER BEDROOM 3 8 6„ \ J �' 6x6 . HA MAST BEDROOM 6x6 130cfm 8" 5„ 0 = 12x12 54cfm 6x6 130 chn WIC WICb �'txa 6x6 32cfm[ 6x6 ,wPrt 61 cim 3A 4„ 6" MAST BATH 12x12 -- 137 cfm 6x6 gI✓ 1: LAUNDRY 6x6 129 cfm k 6x6 110 cfm 5„ 7' 6x6 137 c6n 6" BEDROOM 2 GARAGE Job #: Clyde Nitchell Jr. Residence WebREPS, LLC Scale: 1 : 84 Perfomred by Kenneth D. Pu2inas for. Page i Maurice 188082ndAveue Suile 203 RightSLiteOUniversal 2019 800 Virginia Avenue -%its 59A Mam BeaFL 32966 19.0.13 RSLJ16998 FoAfleice, FL 34982 971-29 od0���810-3280 FaJ@ 201944ov2015:38:03 Phone: 954-649-7269 wwwacducAiesign.com manua]J@webrepshvac.com ... �arielClyde Mtchell Jnup maudoe@mpshvaccom + wrightsofto Duct System Summary Entire House WebREPS, LLC Job: Clyde Mitchell Jr. Residence Date: Jun 03, 2019 By. Kenneth D. PuzInas 188082nd Aeue Sub 203.Wro Beach, FL 32966 Phone: SOM103280 Fax888-971-2999 EMH:manuaL)@mbmpsh'amm NBb:V zaluctdesign.mmLimnm:CAC054709 For: Maurice E., Shazier 800 VirginiaAvenue Suite 59-B, Fort Pierce, FL34982 Phone:954-649-7269 Email: maudoe@repshvec.cem External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (rEL) Heating 0.60 in H2O 0.23 in H2O 0.37 in H2O 0.223 / 0.147 in H2O 0.102 in/10011 1333 ctm 362 it Cooling 0.60 in H2O 0.23 in H2O 0.37 in H2O 0.223 / 0.147 in H2O 0.102 in/10011 1333 cfm Name Design (Btuh) Htgq (101171) Clg (Cfm) Design FIR Diam (In) HxW (in) Dud Mat Actual Ln (ft) Ftg.Egv Ln (it) Trunk BAH C 127 4 7 0.213 4.0 0x0 VIFx 10.1 95.0 BEDROOM2 C 2537 109 137 0.169 6.0 0x0 VIFx 12.6 120.0 st2 BEDROOM3 h 1926 129 70 0.132 6.0 Ox0 VIFx 23.7 145.0 st1 BEDROOM3-A h 1926 129 70 0.133 6.0 0x0 VIFx 22.7 145.0 st1 DINING c 2052 81 111 0.107 5.0 Ox0 VIFx 43.6 165.0 st4 DINING -A C 2052 81 111 0.106 5.0 Ox0 VIFX 46.4 165.0 s14 FOYER h 1680 112 75 0.219 5.0 0x0 VIFx 7.0 95.0 GREITROOM C 3363 131 181 0.124 7.0 0x0 VIFx 35.8 145.0 st3 KRCHEN c 3548 94 191 0.105 7.0 0x0 VIFx 47.5 165.0 st4 LAUNDRY h 1643 110 93 0.161 5.0 0x0 VIFx 13.8 125.0 st2 MAST BAH h 916 61 55 0.151 4.0 Ox0 VIFx 17.6 130.0 s12 MAST BEDROOM h 1950 130 111 0.108 6.0 OXO VIFx 36.1 170.0 st5 MASTBEDROOWA h 1950 130 111 0.102 6.0 Ox0 VIFX 38A 180.0 st5 wlCb h 486 32 11 0.104 4.0 0x0 VIFx 402 175.0 st5 ® -Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (Cfm) FIR (fpm) (In) (In) Material Trunk st4 PeakAVF 255 413 0.105 756 10.0 0 x 0 VinlFlx st3 st5 PeakAVF 293 234 0.102 839 8.0 0 x 0 VinlFlx st3 st1 PeakAVF 2571 139 0.132 737 8.0 0 x 0 VinlFlx st3 PeakAVF 679 828 0.102 774 14.0 0 x 0 VinlFlx st2 s12 PeakAVF 960 1112 0.102 629 18.0 0 x 0 VinlFlx Wrighttsaft' 2019-NDv2015:3723 Rgh4SuiteOUniwml2D1919.0.13RSU16998 Pagel �iCK _Custom Cenaete(Shaaer)1CIyde l.Stchell Jrf p Calc=MI8 Fmnt D0Drtams S Return Branch Detail Table 1 Grille Htg Clg TEL Design Veloc Diam HxW Stud/Joist Dud Name Size (in) (dm) (dm) (ft) FR (fpm) (in) (in) Opening (in) Mat Trunk rb3 Ox 0 109 137 120.5 0.122 697 6.0 Ox 0 VIFx rt2 rb2 Ox 0 354 289 143.2 0.102 649 10.0 Ox 0 VIFx rt2 rb4 Ox 0 129 70 95.0 0.154 655 6.0 0x 0 VIFx rt1 rb5 Ox0 741 838 97.0 0.151 600 16.0 Ox 0 VIFx rt1 Return Trunk Detail Table Trunk Htg CIg Design Veloc Diam H x W Dud Name Type (dm) (cftn) FR (fpm) (in) (in) Material Trunk rt2 PeakAVF 463 425 0.102 850 10.0 0 x 0 VinlFlx rt1 rt1 PeakAVF 1333 1333 0.102 611 20.0 0 x 0 VinlFlx 1 wrightsOfC' 2019.Noo-2015:3723 .,,tsof.* RIgh4Suite®Uniwm[201919.0.13RSU16998 Page2 _Cullom Conmte(Shaner)1Clyde RSlrhell Jrnp Calc=MI9 Fmnt Coorfaoes5