HomeMy WebLinkAboutHEAT PUMP MANUALULTRATEMPT'
"- SCANNED
BY
St. Lucie Count
IICf
COID GG
l
LASS PERFORMANCE AND EFFICIENCY.
ENVIRONMENTALLY SUPERIOR.
MORE STANDARD FEATURES THAN ANY OTHER.
With today's record energy costs, there's never been a better time to invest in a heat pump. Compared to gas, oil or electric heaters,
UltraTemp° High Performance Heat Pumps usejust a fraction of the energy to generate the same amount of heat: In fact, just 202 worth
of electricity produces $1.00 worth of heat generated by other methods. That means more comfortable water temperatures and longer
swimming seasons for you and your family.
Why should you choose an UltraTemp heat pump? That's easy. It offers the longest list of standard features available.
The UltraTemp heat pump provides
an AutoSetrm Temperature Control
feature as standard. It monitors water
temperature and turns the pump on and
off as needed, overriding the time clock
to maintain desired temperature. It's
the ultimate in convenient, hands -free
comfort control.
• The UltraTemp heat pump features the
legendary Emerson" Copeland Scroll®
Compressor that's more efficient, durable,
reliable and quieter than any piston -driven
compressor. It's the best of the best.
• Pentair heat pumps have been using
the EPA -recognized, environmentally
safe, non -ozone depleting R-410A
refrigerant for over 10 years. This
has allowed the UltraTemp heat pump
to be awarded the Eco Select® Brand
for environmental responsibility.
• 100% titanium heat exchanger assures
corrosion -free performance for extra long
life and value.
• LCD control board displays an intuitive,
menu -driven readout with easy to follow, full
word messages —no codes to memorize.
• Self -diagnostic software continuously
monitors system for peak performance.
• Thermostatic Expansion Valve ITxvI
controls refrigerant flow for optimum
efficiency and BTU output over a wider
operating temperature range.
• Automatic defrost feature senses
refrigerant temperature and helps
prevent the UltraTemp heat pump from
freezing, allowing the unit to operate
effectively at even lower temperatures
than many competing products.
• Perfect companion to IntelliTouch® or
EasyTouch° Control Systems—atl heat
pump instructions and displays can
be transferred to a centralized control
system that manages all your pool/spa
operations and poolscape features.
• ETL listing is your assurance of safer,
dependable operation.
• BTU and efficiency independently
certified by the Air Conditioning, Heating,
and Refrigeration Institute IAHRII. The
AHRI Certified mark is applied only to
HVACR equipment and components that
have been independently tested to certify
that manufacturers performance claims
are accurate.
• 10-year compressor parts and labor
warranty and lifetime warranty on the
titanium heat exchanger. See Limited
warranty for details.
Clearly, a heat pump is the best choice for pool heating. Also clear is the best -in -class performance and value of the fully -featured
UltraTemp heat pump. Contact your pool professional today to learn which model is right for your pool.
Edo -
select
itAPENTAIH c
•9.
The UltraTemp heat pump has earned the Eco Select brand. indicating
it is one of our -greenesr and most efficient equipment choices
AUTOMATIC HEATING/COOLING FEATURE
U, ��•�' ,, ,�el ,� . 1.
U
. l .4e , ,,. 1 11.1
Am, ,, ,I if ,
J
COMPARING THE COST TO HEAT YOUR POOL AND SPA
ff
-..
� �I
s•
ORDERING INFORMATION
f_ _._ _ _._.._
_
. ._,___.. _ __ ___
.-Color-Almond
If 70
460930
75,000/5.8 70,000/5.6
_
50,000/4.0 60 40� 1 230 230
90
460931.
�90,000/5.7
84,000/5.5
60.000/4.0
60
50
1
230
230
110
460932
108,000/6.0
101,000/5.8
72.000/4.0
60
50
1
230
270
120
460933
127,000/5.7
120,000/5,5
82000/4.0
60
50
1
230
270
120
i WC
460935
127000 Heat/5.6
71,600 CooV4.1
120,000/5.4
82,000/4:0
60
50
1
230
2781
460937 -
123.000/5.6
115,000/5.3
81,000/4.0
60
50
3
230
280
I 140
460934
143,000/5.8
134,000/5.6
88,000/4.0
60
50
1
230
320 1
140 WC
460958
140,000 Heat/5.6
71,000 CooV4.1
132.000/5.4
' 85.000/4.0 -
60
50,•
1
"230
320
140C
460928
140000/58
132,000/5.6
86.000/40 _
_
60
_ 50
3
230
320__
_
Color; Black_
_
_
70 BLK
460960
�75 000/5 8
_ 70,000/5.6
_
50 000/4 6
60
- --46 • —
_
- -1 ..
230
_
230
1 90 ELK
460961
90.000/5.7
84,00015.5
60,000/4.0
60
5D
1
230
230 I,
C
460962
108,000/6.0
60
__
230
—��
120 BILK
460963
12_7,000/5.7
_
120,000/5.5
120.004� -
0/5.
82,000/4.0
82.000/4.0
60
_
50
50 �
1
1
230
230''
270
278.
120.
WC BLK
_
460965
_
1 , Hea/4.1 V4.1
71,000 Coo
60
I120
I ELK C
460967
123,000/5.6
115,000/5.3
81,000/4.0
_
60
50
3
230
280
I
140
460964.
140.000/5.6 1
134,000/5.6
88,000/4.0
60
50
1 -
230
320
' 140 H/C
I
460959
140000 HeaV5.6
71,000 Cool/4.1
132,000/5.4
85,000/40
60
50
1
230
320
140C
460929
140,000/5.8
132,U00/5.6
86,000/4.0
60
50
3
230
320
-Rating in accordance with ARI Standard 1160
Which ULtraTemp Heat Pump Model is right for your size pool? You or lair temp. Fo 1%relative humidity/water temp. Fol
your pool professional can go to pentairpool.com, click Support, then
click Calculators to access our Heat Pump Sizing Calculator to find
the perfect UltraTemp Heater model for your specific needs. AVAILABLE FROM;
0 PENTAIR
1620 HAWKINS AVE, SANFORD, NC 27330 800.831.7133 WWW.PENTAIRPOOL.COM
All Pentair trademarks and logos are awned by Pentair or one of its global affiliates. UltmTempm, Inteltnouch°, EasyTouch°, Eco Select'; and AuloSel' are lmdeTarks and/orregistered trademarks of Pentair
Water Pool and Spa. Inc. and/or its affiliated companies in the United States and/ or other countries. Emerson' is a registered trademark of Emerson Electric Co.. Copeland Scmll° is a registered trademark of
Emerson Climate Technologies. Inc Because we are continuously improving our preducts and services. Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity
employer.
pumps • filters • heaters • heat pumps • automation • lighting • cleaners
- sanitizers • water features • maintenance products
11115 Part 11 P1-046 02015 Pentair Water Pool and Spa, Inc. All rights reserved. Q
�;: -
'
Y
•
..�
.. � a
.I�
1
( �
i
..
a
+� �
I
v �.
..
r .,
`�•�x
� rNY.
�Y -
}
�.
,. �.. �i'.. - v '-�
..�
..4_.
4.� A -
-
r!'wf �g`..
.,
_ � e
�} v'.�' ''�a �
t
�i
fii ,'
<��: n
'��>
r
hF�y.
�.
� ,db.43� 'I
Sk , ..
_
n .
tea. � �
1.4
�
4
L Y L� `
r.1.
spa
e
,cam
.J
.:.; t.
.+'Q.,
-
;�....
. 'a. .. � s
�''�
- '�.
6Ill121181l110l181y111ll I�I�IJ
7
SGANlV�®
St-t"c eY
County
PE-18Instruction Manual
Table of Contents
Installation 2
Magnet Switch 2
Additional PASS/RESET Switch 2
Main Unit 3
Install Battery 3
Operation 4
Mode Selection 4
Convenient Mode 4
Safety Mode 5
Set Your Own Code 6
Seven or Fifteen Seconds Time Delay 6
Alarm Reset 6
Trouble Shooting 7
1.0 Installation
1.1 Magnet Switch
Attach the magnet switch onto the door, gate
or sliding door by using the screw or the
double sided foam tape. Keep the gap
between the magnet contacts at
minimum. Align the switch by placing the
plastic pieces with "dot" to "dot". Keep the
gap under 1/2".
If you use the alarm on a
metal fence, please
raise the magnet switch
up using the spacer as
shown, to avoid rtr�
interference caused by
metal shielding. Use the
nylon strap to attach the
spacer and magnet switch onto the metal
posts.
Connect the wire to the back of the main unit
that marked "MAGNET SWITCH".
1.2 Additional PASS/RESET Switch
Put this switch on the pool side of the fence or door for
convenient walk in and walk out control.
Connect the wire to the back of the main unit marked
"PASS/RESET'
It is recommended to put the PASS/RESET switch on
the pool side of the fence or door.
2
PASS/RESET
switch
1.3 Main Unit
m,
Attach the mounting bracket by screw
to a wooden post or by nylon strap
onto a metal post as shown. The
} .
main unit can be put into the
`r
mounting bracket.
It is recommended that you mount this.
main unit on the entrance side.
mounting
bracket
1.4 Install Battery
Main unit
This unit is designed to run on 6 pcs AA batteries. When you put in
the top batteries, be sure that they are placed flat but not tilted.
The unit has a built in microprocessor to monitor the batteries. When
the batteries are
running low, it
will chirp once T w
every 60 M1
seconds. When
this happens,
simply replace
them with new
Battery tilted
Batteryflat
3
2.0 Operation
2.1 Mode Selection
The unit is designed
to give you a
choice of either
"Safety mode (S)"
or "Convenient
mode (C)". Both modes can be
programmed for 7 seconds or 15 seconds
door open delay.
The mode selection switches are placed
under the top batteries. Slide to "S" to
select Safety Mode. Slide to "C" to select
Convenient Mode. See below for
explanation of each mode.
Slide to 7 s" to select 7 seconds delay, slide
to 15 s" to select 15 seconds delay.
Press ENTER and hold for one second to finish the mode change.
2.2 Convenient Mode
When this "C" mode is selected, only the
orange button on the main unit and the
PASS/RESET switch are active. Pressing
either key allows you to open the door for 7
seconds or 15 seconds without sounding the
d h
alarm. When either key is presse , t e
�
red LED will flash indicating the unit
..
is ready for you to open the door. You:
have 30 seconds to do it.
,t=^
If you press the orange key and want to r
cancel it, press "C" key and the red ?"
LED stops flashing. The unit is now
reset.
0
If the door is opened without pressing either key or the door is opened
for too long, alarm will sound. To reset the unit, first close the door and
then press either key. Alarm will not reset if door remains open.
2.3 Safety Mode
When this mode is select, the unit is controlled by code
entry. The factory default code is 1 + 2 + 3 + 4. To
get a 7 seconds or 15 seconds delay, enter the
correct code and the red LED will flash. You can
then open the door for up to 7 seconds or 15
seconds without sounding alarm.
Pressing the PASS/RESET switch also
allows you to open the door for 7
seconds or 15 seconds without
sounding the alarm.
After you set the time delay but you want
to cancel it, press "C" key and the red
LED stops flashing. The unit is now
reset.
If the door is opened without pressing the�PASS/RESET key or without
the correct code on the main unit, or if the door is opened for too long,
the alarm will sound. To reset the unit, first close the door and then
press PASS/RESET key or enter the correct code on the main unit.
Alarm will not reset if door remains open.
It is recommended that you the PASS/RESET switch on the pool side
and put the main unit on the entrance side.
IMPORTANT NOTE:
5
2.3 Set Your Own Code
You can set your own favorite 4 digit code. If the unit is
newly installed or the battery is removed, the unit
will automatically be set to the factory default code,
which is 1 + 2 + 3 + 4. To set the code, first enter the
previous set code. When the red LED flashes, press
and hold the "S" key for 3 seconds until you hear 3
beeps.The red LED will stay ON. Enter your
favorite 4 digit code. At the end you will hear
a long beep indicating that the code entry is
successful.
If you have pressed the wrong key, simply press
the "C" key and start over again.
2.4 Seven or Fifteen Second Time Delay
If you select 7 second delay, the unit allows you to open the door for 7
seconds without sounding the alarm. The same is true for 15 second
selection. To get this time delay, follow the instructions described in
2.1 or 2.2.
This time delay will be canceled in 30 seconds after the appropriate key
is pressed or correct code is entered. The unit will reset automatically.
2.5 Alarm Reset
You can reset the unit after alarm goes off by pressing the orange key,
the PASS/RESET key or entering the correct code, depending on "S'
or"C" mode selected. If no key is pressed, alarm will reset in 3 minutes
if the door is closed. However, if the unit detects the door is left opened,
the alarm will continue to sound.
3.0 Trouble Shooting
0.1 cannot change the mode.
After mode selection, press and hold the ENTER switch for at least 1
second. Refer to section 2.1. This allows the unit to reprogram the
microprocessor to accept the new mode selection.
Q. False alarm.
The alarm is triggered if the magnet contact switch is separated. Check
the magnet switch alignment, make sure the plastic pieces are aligned
"dot" to "dot".
If you install the unit on a metal fence, make sure the magnet contact
switch pieces are raised high enough to avoid the shielding interference
caused by the metal.
Check the connection of wires.
Q. 1 have pressed the orange key, PASS/RESET key or entered the
correct code but the alarm sounds when I open the door.
The unit will reset by itself in 30 seconds after any key entry. This prevents
the unit from being disabled forever if you have pressed the key(s) by
accident.The red LED flashes to indicate the time delay is still in force.
If the time delay is canceled and the unit is reset, the red LED is out.
Q. I have forgotten the code.
Remove the battery and the unit will be set to the default code, which is
1 + 2 + 3 + 4. Set your own favorite code by following the procedure
described in section 2.3
Q. The unit makes a chirp every minute.
This indicates the batteries are running low. Replace them with new ones.
Q. Can I use the unit on sliding door?
Yes. Mount the magnet switch on your sliding door so'that the two plastic
pieces are separated if the door is opened.
Q. Can I turn the unit off so that 1 can leave the door open?
No. The unit is an "always ON' device, as required by the Barrier Code.
Once you install the battery, the unit cannot be turned off, similar to a
smoke'detector in your house.
7
For installation questions, call 877-799-7665 (toll free)
weekdays 1- 4 pm EST.
SmartPool Inc.
575 Prospect Street
Lakewood
NJ 08701 Printed in China 0300
Q