Loading...
HomeMy WebLinkAboutTOTAL DYNAMIC HEAD (TDH) CALCULATIONS WORKSHEETPROJE:CF NAME: PEREZ RESIDENTIAL POOL PRO) ECTADDRESS: 12103 RIVERBEND RD. PORT ST. LUCIE. FL TOTAL DYNAMIC HEAD (TDH) CALCULATION WORKSHEET DETERMINE MAXIMUM FLOW RATE PER ANSI / ASPS-15 2013 FRICTION LOSS FOR 2 inch SUCTION PIPE PER ft AT 84 gpm = 0.10— -ft (PER TABLE) FRICTION LOSS FOR 1.5 inch RETURN PIPE PER ft AT 63 gpm = 0.21 ft (PER TABLE) 90 ft. SUCT. PIPE X 0.10 ft HEAD / ft = 9 TDH FOR SUCT. PIPE 100 ft. RETURN PIPE X 0.21 ft HEAD / ft = 21 TDH FOR RETURN PIPE TABLE: SMOOTH PIPE SCH 40 PVC / FLOW AND FRICTION LOSS PER FT PIPE DIAMETER (in) 6 ft/sec 8 ft/sec 10 ft/sec 1 16 gpm 1 0.13 ft 22 gpm 0.23 ft 27 gpm 0.35 ft 1.5 38 gpm 0.08 ft 51 gpm 0.14 ft 63 gpm 0.21 ft 2 63 gpm 0.06 ft 84 gpm 0.10 ft 105 gpm 0.16 ft 2.5 90 gpm 0.05 ft 119 gpm 0.08 ft 149 gpm 0.13 ft 3 138 gpm 0.04 ft 184 gpm 0.07 ft 230 gpm 0.10 ft 4 238 gpm 0.03 ft 317 gpm 0.05 ft 397 gpm 0.07 ft SCANNED BY St. Lucie County \\\\\\ G11 H U TCy se O , I� a — * ATE ; i ` IIIll\\\\\\\ 9/ SIGNATURE /DATE SIGNATURE /DATE CONTRACTOR: BENCHMARK ENGINEERING CERT. # BOWDOIN G. HUTCHINSON P.E. Sheet 2 of 3 CERT# 70878 PROJECT NAME: PROJECT ADDRESS: 70 30 10 . 00 PEREZ RESIDENTIAL POOL 12103 RIVERBEND RD. PORT ST. LUCIE, FL Mm%VS Ped00nmee Cwnpuism —230V =3M RPM ... _ _. ---fl5V r3000 RPM 2400 RPM s�1725 RFM ' Iwo RPM TO 20 30 40 50 e0 m so �90 Raw (GPM) �f TDH IN PIPING: 30.0 ft FILTER LOSS IN TDH: 8.0 ft HEATER LOSS IN TDH 2.4 ft OTHER LOSSES IN TDH: 0.0 ft TOTAL SIMPLIFIED TDH: 40.4 ft NOTES: 1) PUMP OR HEATER MAKE / MODEL MAY NOT BE CHANGED 2) INSTALLATION SHALL COMPLY WITH MANUFACTURER'S IN 3) EQUIPMENT LOCATIONS MAY NOT BE CHANGED. 4) VARIABLE SPEED PUMP USE MAXIMUM FLOW IN CALCULAI SIGNATURE / DATE CONTRACTOR: CERT. # Sheet 3 of 3 SIG 0\1IIIt////// tR G. HUTC,h�//,/�i s 878 Z NAA- .,.,\\\ BOWDOIN G. HUTCHINSON P.E. CERT# 70878