HomeMy WebLinkAboutPRODUCT EVALUATION REPORTjJ/7�
Force Englneering & Testing Inc.
19530 Ramble od Ddve
Humblc,TX 77338
Product Evaluation Report
CARPORTS ANYWHERE
Hampton Rib Wall Panel over open framing
Florida Product Approval # 27403.1
Florida Building Code 2017
Per Rule 61G20-3
Method: 2-B
Category: Structural Components
Subcategory: Structural Wall
Compliance Method: 61G20-3.005(2)(b)
NON HVHZ
Product Manufacturer:
Carport Anywhere
10959 S.E. County Road 221
Starke, Florida 32091
Engineer Evaluator:
Terrence E. Wolfe, P.E. # 44923
Florida Evaluation ANE ID: 1920
Validator•
Gary Hartman, P.E. 473227
Contents:
Evaluation Report Pages 1-4
SCANNED
BY
St. Lucie County
tttt11111 N 111I
N C E. E., lye 1.1i
4�Q' Vt CE NSF<.n
No. 44e9
STATE OF ; s
sa. Doneas%
aamu 1�1 %� H 1111� �tttt
FL# 27403.1
Ju.vl.e.18, 2018
Force Engineering & Testing Inc.
19530 Ramblawood Drive
Hvmble,TX 77338
Compliance Statement: The product as described In this report has demonstrated compliance with the
Florida Building Code 2017, Sections 1709.2.
Product Description: Hampton Rib 26 Ga. and 29 Ga. Steel Wall Panel, 36" Wide, through fastened
structural wall panel. Structural Application.
Panel Material/Standards: Material:
26 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade SO
29 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 80
Conforming to Florida Building Code 2017 Section 1405.2.
Panel Dimenslon(s): Thickness: 26 Ga.: 0.0185" min. order thickness
29 Ga.: 0.0142" min. order thickness
Width: 36" maximum coverage
Rib Height: W major rib at 9" O.C.
Panel Rollformer: MRS Metal Rollforming Systems
Panel Fastener: #12-14 x W HWH SDft3 with 14mm neoprene bonded washing or approved
equal.
Corrosion Resistance: Per Florida Building Code 2017.
Substrate Description: Minimum 14 Ga. (Grade 50) Steel framing, Minimum 16 Ga. (Grade 50) Steel
framing, or Minimum 18 Ga. (Grade 50) Steel framing. See Table A&Bfor steel
gauge. Framing must be designed in accordance W/ Florida Building Code 2017.
Allowable Design Pressures:
Table "A" 26 Ga. Hampton Rib Wall Panel
Maximum Dwlgn Pressure:
-57.3 psf
-72.9 psf
-67.7 psf
+46.9 psf
+54.7 psf
Panel Fastener Pattern:
2-1.2-1
2-1-2-1
2.1.2.1
2.1-2-1
2-1-2-1
Panel Span:
S'-01 O.0
4'-0. O.C.
W-W O.C.
51-W O.C.
4'-0"O.C.
Substrate:
Min. 14 Ga.
Steel Framing
Min. 14 Ga.
Steel Framing
MIn. 14 Ga.
Steel Framing
Min. 18 Ga.
Steel Framing
Min. 18 Ga.
Steel Framing
•Design Pressure includes a Safety Factor= 2.0.
���3s3N C E r f t,2jrr. CENSF Cam.
No. 40 /
STATE OF ; e: 4,.
���•pt
O RI 9
srsrmf +� f4; •.
FL# 27403.1
Ju.we.19, zola
rForcc Engineering & Testing Inc.
195301tamblmood Drive
Hwnble,TX 77338
Table "B" 29 Ga. Hampton Rib Wall Panel
Maximum Design Pressure:
-57.3 psf
-1509 psf
+39.0 psf
+143.1 psf
Fastener Pattern:
6'-3"-6'-3"-6'-3"6'
6'-3"-6"3"-6"-3•-6•
6'_3•-6•_3•-6•_3•.6•
6•-3'-6'3'-6 3'-6'
Fastener Spacing:
4'-0"O.0
r-W O.C.
4'-W O.C.
2'-W O.C.
'Design Pressure Includes a Safety Factor= 2.0.
Code Compliance:
The product described herein has demonstrated compliance with
The Florida Building Code 2017, Section 1709.2.
Evaluation Report Scope:
The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2017, as relates to Rule 6IG20-3.
Performance Standards:
The product described herein has demonstrated compliance with:
• ASTM E 1592-05 (2012) Test method for structural performance of
sheet metal roof and siding systems by uniform static air pressure
difference
Reference Data:
1. ASTM E 1592-05 (2012) Test
Force Engineering & Testing, Inc. (FBC Organization 0 TST-5328)
Report No. 667-OO60T-18A-E, 667-0061T-18A-D
2. Certificate of Independence
By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc.
(FBC Organization 0 ANE 10: 1920)
Quality Assurance Entity:
The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 614320-3.005 (3) for
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
Installation:
Install per manufacturer's recommended details.
Insulation:
Manufacturer's approved product (Optional)
Panel Fire Classification:
Fire classification Is not part of this acceptance.
FL# 27403.1
C E H
No. 449
-*
'•' STATEOF :or
10 AL0x11) ,,
s ons6rw� i� SS �G \�
Jfwre.28' 2018
rForceEngineering & Testing Inc.
19530 Ramble od Drive
Humble,TX 77338
Shear Diaphragm: Shear diaphragm values are outside the scope of this report
Design Procedure: Based on the dimensions of the structure, appropriate wind loads are
determined using Chapter 16 of the Florida Building Code 2017 for wall cladding
wind loads. These componentwind loads for wall cladding are compared to the
allowable pressure listed above. The design professional shall select the
appropriate erection details to reference In his drawings for proper fastener
attachment to his structure and analyze the panel fasteners for pullout and
pullover. Support framing must be in compliance with Florida Building Code 2017
Chapter 22 for steel, and Chapter 16 for structural loading.
����t�ptc E tE rrrr�ri f; ..... h•G � 0
No. 410
STATE OF ,
Oki �44
s..srw, i S •. 'b
ism �0,, , j
FL# 27403.1
Ju.a.e 3.8, 2018
26 GA. HAMPTON RIB FASTENER PATTERN 2-1-2-1
112-14 • 3/4' HWH S03 W/ 14MM BONDED NEOPRENE WASHER
29 GA. HAMPTON RIB FASTENER PATTERN 6"-3"-6"-3"-6"-3"-6"
6' _._3._ . _ 6" _ . _3_ _ 6' 3' 6'
912-14 a 3/4' NWII S03 W/ 141IM BONDED NEOPRENE WASHER
al flo11d9
Iflry7/// ��,OA
E. In�//b. OfieTB
No.44923
:r
Ek=
of
STATE 04
;+;4/�,�
(BAN 1 8 2818
FL# 27402.1 RI
rForceEngin.rreTesting Inc.930 =.wod Ddvo
HumblglX 77339
Product Evaluation Report
CARPORTS ANYWHERE
Hampton Rib Roof Panel over open framing
Florida Product Approval # 27402.1 R1
Florida Building Code 2017
Per Rule 61G20-3
Method: I—D
Category: Structural Components
Subcategory: Roof Deck
Compliance Method: 61G20-3.005(l)(d)
NON HVHZ
Product Manufacturer:
Carport Anywhere
10858 S.E. County Road 221
Starke, Florida 32092
Engineer Evaluator:
Terrence E. Wolfe, P.E. # 44923
Florida Evaluation ANE ID: 1920
Validator:
Brian Saks, P.E. #70159
Contents:
Evaluation Report Pages 1-4
,III' I I I I i It I,..,
,III E N G E F
CE/YSF
STATEOF ;<
O RI
m.�r1r�+. . • ti
11 j 1151111,
August 8, 2019
SCANNED
BY
St. Lucie County
rForce:�
Engineering &Testing Inc.
19530 Rambl.d Drivc
Humblc,TX 77338
Compliance Statement:
The product as described in this report has demonstrated compliance with the
Florida Building Code 2017, Sections 1504.3.2, 1504.7.
Product Description:
Hampton Rib 26 Ga. and 29 Ga. Steel Roof Panel, 36" Wide, through fastened
structural roof panel. Structural Application.
Panel Material/Standards:
Material:
26 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 50
29 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 80
Conforming to Florida Building Code 2017 Section 1507.4.3. Optional paint finish.
Corrosion Resistance: Panel Material shall comply with Florida Building Cade
2017, Section 1507.4.3.
Panel Dimension(s):
Thickness: 26 Ga.: 0.0185" min. order thickness
29 Ga.: 0.0142" min. order thickness
Width: 36" maximum coverage
Rib Height: Y." major rib at 9" O.C.
Panel Rollformer: MRS Metal Rollforming Systems
Panel Fastener:
#12-14 x Y" HWH SD#3 with 14mm neoprene bonded washing or approved
equal.
Corrosion Resistance: Per Florida Building Code 2017, Section 1507.4.4.
Substrate Description:
Minimum 14 Ga. (Grade 50) Steel framing, Minimum 16 Ga. (Grade 50) Steel
framing, or Minimum 18 Ga. (Grade 50) Steel framing. See Table A & B for steel
gauge. Framing must be designed in accordance w/ Florida Building Code 2017.
Allowable Design Pressures:
Table "A" 26 Ga. Hamoton Rib Roof Panel
Maximum Design Pressure:
-S7.3 psf
-72.9 psf
-673 psf
.46.9 psf
.54.7 psf
Panel Fastener Pattern:
2-1-2-1
2-1-2-1
2-1-2-1
2-1-2-1
2-1-2-1
Panel Span:
5'-0.O.C.
4'-0"O.C.
4'-0"O.C.
S'-0"O.C.
4'-0"O.C.
Substrate:
Min. 14 Ga.
Steel Framing
Min. 14 Ga.
Steel Framing
Min. 18 Ga.
Steel Framing
Min. 18 Ga.
Steel Framing
Min. 18 Ga.
Steel Framing
-Design Pressure Includes a Safety Factor= 2.0.
sS�3`sN CtE I Eft ,11�i
,, F; ..... {yo �i
CE♦ZSF
No. 449
STATE OF or
�i0w`•ALor', •t+4-.
imr '4,i�So0to 11
2ft0 ?
FL# 27402.1 R1
August 8, 2019
rForccEnlgeineeri',�g&Testing Inc.
9Rnmwood Drive
HumblgTX 77338
Table •8" 29 Ga- Hammm. Rih
Maximum Design Pressure:
-57.3 psf
-150.9 psf
+39.0 psf
+143.1 psf
Fastener Pattern:
6'-3"-6"-3"-6"-3"-6"
6"-3"-6"-3"-6"-3'-6"
6"-3--6"-3--6'-3--6-
6--3"-6--3"-6"-3--6"
Fastener5pacing:
4'-0' O.0
2'-0" O.C.
4'-0' O.C.
2'-0" O.C.
Substrate:
Min. 16 Ga.
Steel Framing
Min. 16 Ga.
Steel Framing
Min. 16 Ga.
steel Framing
Min. 16 Ga.
Steel Fmming
-Design Pressure induces a batety Fattor = 2.0.
Code Compliance:
The product described herein has demonstrated compliance with
The Florida Building Code 2017, Section 1504.3.2, 1504.7.
Evaluation Report Scope:
The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2017, as relates to Rule 61G20-3.
Performance Standards:
The product described herein has demonstrated compliance with:
• ASTM E 1592-05 (2012) Test method for structural performance of
sheet metal roof and siding systems by uniform static air pressure
difference
• FM 4471-92- Foot Traffic Resistance Test
Reference Data:
1. ASTM E 1592-05 (2012) Test
Force Engineering & Testing, Inc. (FBC Organization # TST-5328)
Report No. 667-006OT-18A-E, 667-0061T-18A-0
2. FM 4471-10, Section 4.4 Foot Traffic Resistance Test
Force Engineering & Testing, Inc. (FBC Organization 0 TST-5328)
Report No. 667-0060T-18F, 667-0061T-18E
3. Certificate of Independence
By Terrence E. Wolfe, P.E. (No. 449231 @ Force Engineering & Testing, Inc.
(FBC Organization # AN E ID: 1920)
Test Standard Equivalency:
The FM 4471-10, Foot Traffic Resistance test standard is equivalent to
FM 4471-92.
Quality Assurance Entity:
The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.005 (3) for
���3t�p1C E rE rr7r�i�
w.' V F
�'a• STATE OF ;r<
°.•FLOR.IDA 4:
FL# 27402.1 RI
August 8, 2019
�y
Force Engineenng Bc Testing Inc.
19S30 Rombl.00d Ddve
Humblc,TX 77338
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, Including Section
1507.4.2 and in accordance with Manufacturers recommendations. For slopes
less than 3:12, lap sealant must be used in the panel side laps.
Installation: Install per manufacturers recommended details.
Insulation: Manufacturers approved product (Optional)
Roof Panel Fire Classification: Fire classification Is not part of this acceptance.
Shear Diaphragm: Shear diaphragm values are outside the scope of this report.
Design Procedure: Based on the dimensions of the structure, appropriate wind loads are
determined using Chapter 16 of the Florida Building Code 2017 for roof cladding
wind loads. These component wind loads for roof cladding are compared to the
allowable pressure listed above. The design professional shall select the
appropriate erection details to reference in his drawings for proper fastener
attachment to his structure and analyze the panel fasteners for pullout and
pullover. Support framing must be in compliance with Florida Building Code 2017
Chapter 22 for steel, and Chapter 16 for structural loading.
Js�`�fc ik C'E'E r�O ♦♦
b' STATE OF ; a
W`
°.e. pLoRI9A.��
a.srmr ♦♦ Fs •. 1
ima ♦♦♦♦ II 1111 t� N` %
FL# 27402.1 RI
August 8, 2019
26 GA. HAMPTON RIB FASTENER PATTERN 2-1-2-1
R12-14 . 3/4' H.W4 SDJ Vl/ I4M:6 BONDED NEOPRENE WASHER
29 GA. HAMPTON RIB FASTENER PATTERN 6"-3"-6"-3 6"-3"-6"
912-14 x 3/4' IDVH 503 V// 14MM BONDED NEOPRENE WASHER
MoofFlodft
O.OA
4267M
I11111111111//11//
NGE E: �i//
No. 44933 •:4°�
STATE OF L.1�L
F2 tdA1O P•� ��.
August 8, 2019