Loading...
HomeMy WebLinkAboutPRODUCT EVALUATION REPORTjJ/7� Force Englneering & Testing Inc. 19530 Ramble od Ddve Humblc,TX 77338 Product Evaluation Report CARPORTS ANYWHERE Hampton Rib Wall Panel over open framing Florida Product Approval # 27403.1 Florida Building Code 2017 Per Rule 61G20-3 Method: 2-B Category: Structural Components Subcategory: Structural Wall Compliance Method: 61G20-3.005(2)(b) NON HVHZ Product Manufacturer: Carport Anywhere 10959 S.E. County Road 221 Starke, Florida 32091 Engineer Evaluator: Terrence E. Wolfe, P.E. # 44923 Florida Evaluation ANE ID: 1920 Validator• Gary Hartman, P.E. 473227 Contents: Evaluation Report Pages 1-4 SCANNED BY St. Lucie County tttt11111 N 111I N C E. E., lye 1.1i 4�Q' Vt CE NSF<.n No. 44e9 STATE OF ; s sa. Doneas% aamu 1�1 %� H 1111� �tttt FL# 27403.1 Ju.vl.e.18, 2018 Force Engineering & Testing Inc. 19530 Ramblawood Drive Hvmble,TX 77338 Compliance Statement: The product as described In this report has demonstrated compliance with the Florida Building Code 2017, Sections 1709.2. Product Description: Hampton Rib 26 Ga. and 29 Ga. Steel Wall Panel, 36" Wide, through fastened structural wall panel. Structural Application. Panel Material/Standards: Material: 26 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade SO 29 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 80 Conforming to Florida Building Code 2017 Section 1405.2. Panel Dimenslon(s): Thickness: 26 Ga.: 0.0185" min. order thickness 29 Ga.: 0.0142" min. order thickness Width: 36" maximum coverage Rib Height: W major rib at 9" O.C. Panel Rollformer: MRS Metal Rollforming Systems Panel Fastener: #12-14 x W HWH SDft3 with 14mm neoprene bonded washing or approved equal. Corrosion Resistance: Per Florida Building Code 2017. Substrate Description: Minimum 14 Ga. (Grade 50) Steel framing, Minimum 16 Ga. (Grade 50) Steel framing, or Minimum 18 Ga. (Grade 50) Steel framing. See Table A&Bfor steel gauge. Framing must be designed in accordance W/ Florida Building Code 2017. Allowable Design Pressures: Table "A" 26 Ga. Hampton Rib Wall Panel Maximum Dwlgn Pressure: -57.3 psf -72.9 psf -67.7 psf +46.9 psf +54.7 psf Panel Fastener Pattern: 2-1.2-1 2-1-2-1 2.1.2.1 2.1-2-1 2-1-2-1 Panel Span: S'-01 O.0 4'-0. O.C. W-W O.C. 51-W O.C. 4'-0"O.C. Substrate: Min. 14 Ga. Steel Framing Min. 14 Ga. Steel Framing MIn. 14 Ga. Steel Framing Min. 18 Ga. Steel Framing Min. 18 Ga. Steel Framing •Design Pressure includes a Safety Factor= 2.0. ���3s3N C E r f t,2jrr. CENSF Cam. No. 40 / STATE OF ; e: 4,. ���•pt O RI 9 srsrmf +� f4; •. FL# 27403.1 Ju.we.19, zola rForcc Engineering & Testing Inc. 195301tamblmood Drive Hwnble,TX 77338 Table "B" 29 Ga. Hampton Rib Wall Panel Maximum Design Pressure: -57.3 psf -1509 psf +39.0 psf +143.1 psf Fastener Pattern: 6'-3"-6'-3"-6'-3"6' 6'-3"-6"3"-6"-3•-6• 6'_3•-6•_3•-6•_3•.6• 6•-3'-6'3'-6 3'-6' Fastener Spacing: 4'-0"O.0 r-W O.C. 4'-W O.C. 2'-W O.C. 'Design Pressure Includes a Safety Factor= 2.0. Code Compliance: The product described herein has demonstrated compliance with The Florida Building Code 2017, Section 1709.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 6IG20-3. Performance Standards: The product described herein has demonstrated compliance with: • ASTM E 1592-05 (2012) Test method for structural performance of sheet metal roof and siding systems by uniform static air pressure difference Reference Data: 1. ASTM E 1592-05 (2012) Test Force Engineering & Testing, Inc. (FBC Organization 0 TST-5328) Report No. 667-OO60T-18A-E, 667-0061T-18A-D 2. Certificate of Independence By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc. (FBC Organization 0 ANE 10: 1920) Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 614320-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Installation: Install per manufacturer's recommended details. Insulation: Manufacturer's approved product (Optional) Panel Fire Classification: Fire classification Is not part of this acceptance. FL# 27403.1 C E H No. 449 -* '•' STATEOF :or 10 AL0x11) ,, s ons6rw� i� SS �G \� Jfwre.28' 2018 rForceEngineering & Testing Inc. 19530 Ramble od Drive Humble,TX 77338 Shear Diaphragm: Shear diaphragm values are outside the scope of this report Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2017 for wall cladding wind loads. These componentwind loads for wall cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference In his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2017 Chapter 22 for steel, and Chapter 16 for structural loading. ����t�ptc E tE rrrr�ri f; ..... h•G � 0 No. 410 STATE OF , Oki �44 s..srw, i S •. 'b ism �0,, , j FL# 27403.1 Ju.a.e 3.8, 2018 26 GA. HAMPTON RIB FASTENER PATTERN 2-1-2-1 112-14 • 3/4' HWH S03 W/ 14MM BONDED NEOPRENE WASHER 29 GA. HAMPTON RIB FASTENER PATTERN 6"-3"-6"-3"-6"-3"-6" 6' _._3._ . _ 6" _ . _3_ _ 6' 3' 6' 912-14 a 3/4' NWII S03 W/ 141IM BONDED NEOPRENE WASHER al flo11d9 Iflry7/// ��,OA E. In�//b. OfieTB No.44923 :r Ek= of STATE 04 ;+;4/�,� (BAN 1 8 2818 FL# 27402.1 RI rForceEngin.rreTesting Inc.930 =.wod Ddvo HumblglX 77339 Product Evaluation Report CARPORTS ANYWHERE Hampton Rib Roof Panel over open framing Florida Product Approval # 27402.1 R1 Florida Building Code 2017 Per Rule 61G20-3 Method: I—D Category: Structural Components Subcategory: Roof Deck Compliance Method: 61G20-3.005(l)(d) NON HVHZ Product Manufacturer: Carport Anywhere 10858 S.E. County Road 221 Starke, Florida 32092 Engineer Evaluator: Terrence E. Wolfe, P.E. # 44923 Florida Evaluation ANE ID: 1920 Validator: Brian Saks, P.E. #70159 Contents: Evaluation Report Pages 1-4 ,III' I I I I i It I,.., ,III E N G E F CE/YSF STATEOF ;< O RI m.�r1r�+. . • ti 11 j 1151111, August 8, 2019 SCANNED BY St. Lucie County rForce:� Engineering &Testing Inc. 19530 Rambl.d Drivc Humblc,TX 77338 Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2, 1504.7. Product Description: Hampton Rib 26 Ga. and 29 Ga. Steel Roof Panel, 36" Wide, through fastened structural roof panel. Structural Application. Panel Material/Standards: Material: 26 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 50 29 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 80 Conforming to Florida Building Code 2017 Section 1507.4.3. Optional paint finish. Corrosion Resistance: Panel Material shall comply with Florida Building Cade 2017, Section 1507.4.3. Panel Dimension(s): Thickness: 26 Ga.: 0.0185" min. order thickness 29 Ga.: 0.0142" min. order thickness Width: 36" maximum coverage Rib Height: Y." major rib at 9" O.C. Panel Rollformer: MRS Metal Rollforming Systems Panel Fastener: #12-14 x Y" HWH SD#3 with 14mm neoprene bonded washing or approved equal. Corrosion Resistance: Per Florida Building Code 2017, Section 1507.4.4. Substrate Description: Minimum 14 Ga. (Grade 50) Steel framing, Minimum 16 Ga. (Grade 50) Steel framing, or Minimum 18 Ga. (Grade 50) Steel framing. See Table A & B for steel gauge. Framing must be designed in accordance w/ Florida Building Code 2017. Allowable Design Pressures: Table "A" 26 Ga. Hamoton Rib Roof Panel Maximum Design Pressure: -S7.3 psf -72.9 psf -673 psf .46.9 psf .54.7 psf Panel Fastener Pattern: 2-1-2-1 2-1-2-1 2-1-2-1 2-1-2-1 2-1-2-1 Panel Span: 5'-0.O.C. 4'-0"O.C. 4'-0"O.C. S'-0"O.C. 4'-0"O.C. Substrate: Min. 14 Ga. Steel Framing Min. 14 Ga. Steel Framing Min. 18 Ga. Steel Framing Min. 18 Ga. Steel Framing Min. 18 Ga. Steel Framing -Design Pressure Includes a Safety Factor= 2.0. sS�3`sN CtE I Eft ,11�i ,, F; ..... {yo �i CE♦ZSF No. 449 STATE OF or �i0w`•ALor', •t+4-. imr '4,i�So0to 11 2ft0 ? FL# 27402.1 R1 August 8, 2019 rForccEnlgeineeri',�g&Testing Inc. 9Rnmwood Drive HumblgTX 77338 Table •8" 29 Ga- Hammm. Rih Maximum Design Pressure: -57.3 psf -150.9 psf +39.0 psf +143.1 psf Fastener Pattern: 6'-3"-6"-3"-6"-3"-6" 6"-3"-6"-3"-6"-3'-6" 6"-3--6"-3--6'-3--6- 6--3"-6--3"-6"-3--6" Fastener5pacing: 4'-0' O.0 2'-0" O.C. 4'-0' O.C. 2'-0" O.C. Substrate: Min. 16 Ga. Steel Framing Min. 16 Ga. Steel Framing Min. 16 Ga. steel Framing Min. 16 Ga. Steel Fmming -Design Pressure induces a batety Fattor = 2.0. Code Compliance: The product described herein has demonstrated compliance with The Florida Building Code 2017, Section 1504.3.2, 1504.7. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61G20-3. Performance Standards: The product described herein has demonstrated compliance with: • ASTM E 1592-05 (2012) Test method for structural performance of sheet metal roof and siding systems by uniform static air pressure difference • FM 4471-92- Foot Traffic Resistance Test Reference Data: 1. ASTM E 1592-05 (2012) Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 667-006OT-18A-E, 667-0061T-18A-0 2. FM 4471-10, Section 4.4 Foot Traffic Resistance Test Force Engineering & Testing, Inc. (FBC Organization 0 TST-5328) Report No. 667-0060T-18F, 667-0061T-18E 3. Certificate of Independence By Terrence E. Wolfe, P.E. (No. 449231 @ Force Engineering & Testing, Inc. (FBC Organization # AN E ID: 1920) Test Standard Equivalency: The FM 4471-10, Foot Traffic Resistance test standard is equivalent to FM 4471-92. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for ���3t�p1C E rE rr7r�i� w.' V F �'a• STATE OF ;r< °.•FLOR.IDA 4: FL# 27402.1 RI August 8, 2019 �y Force Engineenng Bc Testing Inc. 19S30 Rombl.00d Ddve Humblc,TX 77338 manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, Including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per manufacturers recommended details. Insulation: Manufacturers approved product (Optional) Roof Panel Fire Classification: Fire classification Is not part of this acceptance. Shear Diaphragm: Shear diaphragm values are outside the scope of this report. Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2017 for roof cladding wind loads. These component wind loads for roof cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2017 Chapter 22 for steel, and Chapter 16 for structural loading. Js�`�fc ik C'E'E r�O ♦♦ b' STATE OF ; a W` °.e. pLoRI9A.�� a.srmr ♦♦ Fs •. 1 ima ♦♦♦♦ II 1111 t� N` % FL# 27402.1 RI August 8, 2019 26 GA. HAMPTON RIB FASTENER PATTERN 2-1-2-1 R12-14 . 3/4' H.W4 SDJ Vl/ I4M:6 BONDED NEOPRENE WASHER 29 GA. HAMPTON RIB FASTENER PATTERN 6"-3"-6"-3 6"-3"-6" 912-14 x 3/4' IDVH 503 V// 14MM BONDED NEOPRENE WASHER MoofFlodft O.OA 4267M I11111111111//11// NGE E: �i// No. 44933 •:4°� STATE OF L.1�L F2 tdA1O P•� ��. August 8, 2019